svantek sv 106 human vibration meter & analyzer

Post on 01-Jan-2017

238 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Human Vibration Meter & AnalyzerSvantek SV 106

The SV 106 is a new six-channel human vibration meter and analyser. Instrument meets ISO 8041:2005 standard and it is an ideal choice for measurements according to ISO 2631-1,2&5 and ISO 5349.

This revolutionary, pocket-size instrument enables simultaneous measurements with two triaxial accelerometers (e.g. both-hands vibration or triaxial SEAT transmission measurements are possible).

The RMS, Peak, Peak-Peak, VDV, MTVV, A(8) or Dose results with all required weighting filters for the HVM measurements including band-limiting filters are available with this instrument.

Using computational power of its digital signal processor, the SV 106 can perform real-time 1/1 or 1/3 octave analysis simultaneously to the meter mode.

Advanced time-history logging and time-domain signal recording (according to the ISO 2631-5) to built-in Micro SD flash card give almost

unlimited capabilities of data storage. Results can be easily downloaded to PC using USB interface and SvanPC+_VR software. SvanPC+_VR software also provides the setup-editor function which manages the instrument’s settings.

The Whole-Body vibration measurement is easier thanks to SV 38V seat-accelerometer which can be placed directly on the seat-cushion, floor or fixed to the back of the seat.

The SV 50 set with triaxial accelerometer enables Hand-Arm vibration measurements regardless of the type of evaluated tool.

Additionally, for measurements of very high impulse vibration the special adapter with low pass mechanical filter protecting accelerometer from DC shift effect, is available. Evaluation of the grip force will be accessible with dedicated “integrated adapter” SV 105.

Features• HumanVibrationmeasurementsmeetingISO8041:2005,ISO2631-1,2&5(includingVDVandMTVV)andISO5349

• Sixchannelsforaccelerationandtwochannelsforstaticforcemeasurements

• Eachchannelwithtwoprofiles• Whole-Bodymeasurements:-Low-costandlowpowerseataccelerometerSV38V

• Hand-Armmeasurements:-SV50triaxialaccelerometerwithsetofadapters-SV105integratedtriaxialaccelerometer,adapterandgripforcesensor(underdevelopment)

• Time-domainsignalrecording(meetingISO2631-5)• 1/1and1/3octavereal-timeanalysis• Advanceddataloggerincludingspectralanalysis• MicroSDflashcardformassdatastorage• USB1.1Clientinterface• Integrationtimeprogrammableupto24hours• SvanPC+_VRsoftwareforeasyinstrumentsetupanddatadownload

• Easyinuse,userfriendlyinterfacewithcolordisplay• Pocketsize(140x83x33millimeters)weightonly390gramsincludingbatteries

Sensidyne, LP • 16333 Bay Vista Drive • Clearwater, Florida 33760Tel: 800-451-9444 / +1 727-530-3602 • Fax: +1 727-539-0550 • E-mail: info@Sensidyne.com • Web: www.Sensidyne.com

Svantek SV 106 Human Vibration Meter & AnalyzerTechnicalSpecifications

Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.

VibrationMeterandAnalyser

Standards ISO8041:2005,ISO2631-1,2&5,ISO5349MeterMode RMS,VDV,MTVVorMax,Peak,Peak-Peak,Vector,A(8),Dose,ELV,EAV SimultaneousmeasurementinsixchannelswithindependentsetoffiltersanddetectorconstantsFilters Wd,Wk,Wm,Wb,Wc,Wj,Wg,Wf(ISO2631),Wh(ISO5349)andBandLimitingfiltersRMS&RMQDetectors DigitaltrueRMS&RMQdetectorswithPeakdetection,resolution0.1dB Timeconstantsfrom100msto10sMeasurementRange Transducerdependent: 0.01ms-2RMS÷50ms-2Peak(withSV38VandWdfilter) 0.1ms-2RMS÷5000ms-2Peak(withSV50andWhfilter)FrequencyRange 0.1Hz÷2828Hz(transducerdependent)DataLoggerX Time-historydataincludingmetermoderesultsandspectraTime-DomainRecordingX Simultaneousx,y,ztime-domainsignalrecording, samplingfrequencyselectable:375Hz,3kHzor6kHz(option)AnalyserX 1/1octavereal-timeanalysiswithcentrefrequenciesfrom0.5Hzto2000Hz(option) 1/3octavereal-timeanalysiswithcentrefrequenciesfrom0.4Hzto2500Hz(option)Accelerometer(option) SV38VlowcostandlowpowertriaxialaccelerometerforWhole-Bodymeasurements SV50setforHand–Armmeasurement(Dytranaccelerometer3023M2;adaptersSA50,SA51,SA52)XX

SV105integratedtriaxialHand-Armadapterwithgripforcesensor(underdevelopment)XfunctionparalleltothemetermodeX X SC118integratedconnectorrequired

BasicData

Input 2xLEMO5-pin:sixchannelsDirectorIEPEtypeandtwochannelsforforcetransducersDynamicRange 90dBForceRange 0.2N÷100N(dedicatedchannelsforforcetransducers)SamplingRate 6kHzMemory Internal16MBnon-volatilememory MicroSDflashcardslot(supports8GB÷16GBcards)Display ColourOLED2.4”,320x240pixels Supercontrast10000:1Interfaces USB1.1Client,ExtendedI/O-ACoutput(1VPeak)orDigitalInput/Output(Trigger-Pulse)PowerSupply FourAAbatteries(alkaline) operationtime>12h(6.0V/1.6Ah)XXX

FourAArechargeablebatteries(notincluded) operationtime>16h(4.8V/2.6Ah)XXX USBinterface 500mAHUBEnvironmentalConditions Temperature from-10°Cto50°C Humidity upto90%RH,non-condensedDimensions 140x83x33mm(withoutaccelerometer)Weight Approx.390gramsincludingbatteries(withoutaccelerometer)XXXwithoneSV38Vtriaxialaccelerometerinmetermode