Extreme Networks Data Sheet
Summit X480 Series
Make Your Network Mobile
High-Performance Switching and Routing• 48-portGigabitEthernetor24-portgigabitand2-port10GigabitEthernetconnectivityina1RUformfactor
• Optional4-port10GigabitEthernet(GbE)toprovide40Gbpsuplinks
• Optional40Gbpsstackingforuptoeightswitchesinastacktoprovideupto384GigabitEthernetconnectionsinonelogicallyintegratedunit
• Optional128Gbpsstackingforuptoeightswitchesinastacktoprovidehigh-speedstacking
• Optionalstackingvia10GbEports(SummitStack-V),oroptionalSummitStack-V8080Gbpsstacking
• SupportsLayer2andLayer3switching,aswellasMPLS/H-VPLS
High Scalability in a 1RU Compact Switch • Upto512KMACaddresssupportforscalableLayer2networks
• Upto512KIPv4routesforscalableLayer3networks
• Upto60KAccessControlLists(ACLs)forsecurenetworks
High Availability• ExtremeXOS®modularOSforhighlyavailablenetworkoperation
• Carrier-graderedundantnetworkingprotocolincludingEthernetAutomaticProtectionSwitching(EAPS)
• InternalredundantAC/DCpowersupplyandfieldreplaceable/hotswappablefantray
Summit® X480 Series—the scalable and versatile gigabit and 10 Gigabit Ethernet switch.
TheSummitX480seriesswitchisaversatile,high-endEthernetswitchfordatacenter,enterpriseaggregation,andCarrierEthernetdeployments.SummitX480helpsoptimizeapplicationperformanceforavarietyofnetworkdeploymentswithitsrichfeaturesandhighscalability.
SummitX480provideshighdensityforGigabitEthernetinasmall1RUformfactorforupto48portsinonesystemand384portsinastackedsystemusingback-wardcompatibleSummitStack™,high-speedSummitStack128runningat128gigabitspersecond,orSummitStack-V,whichutilizes10GbEportsasstackingports,enablingtheuseofstandardcablingandopticstechnologiesusedfor10GbE.SummitX480alsooffers10GigabitEthernetconnectivityforuptosixportsinonesystemand16portsinastackedsystemwiththeindustry-standardXFPinterface.
Foremergingdemandsfromvoice/dataconvergenceandstorage,SummitX480provideshighlyscalableLayer2/3switchingandMPLS/H-VPLSbysupportingupto512KLayer2MACaddressesor512KIPv4LongestPrefixMatchroutingtables.SummitX480enablesdatacenter,enterpriseandCarrierEthernetaggregationandcorebackbonedeploymentinAC-poweredandDC-poweredenvironments.
SummitX480simplifiesnetworkoperationwiththeExtremeXOSmodularOS,availableacrossawiderangeofExtremeNetworks®Ethernetswitches.TheExtremeXOSoperatingsystemprovideshighavailabilityandsimplicitywithoneOSeverywhereinthenetwork.
Target Applications• Top-of-rackswitchforserversinenterprisedatacenters
• High-performancecoreswitchforasmallnetwork
• High-performancegigabitaggregationswitchinatraditionalthree-tierednetwork
• CarrierEthernetnetworkswitchthatcanaggregateconnectivityforfirstmileaccessconcentratorssuchasDSLAMandCMTS
2
Extreme Networks Data Sheet: Summit X480 Series
High-Performance and Highly Scalable Switching and Routing Summit X480 offers core-class intelligent switching and routing with exceptional port density and high-performance stacking technology powered by the ExtremeXOS modular OS. With its high performance switching and routing, Summit X480 helps enhance the data center, Carrier Ethernet and enterprise aggregation network.
SummitStack – High-Performance StackingSummitX480supportsSummitStack,whichprovides40Gbps(VIM2-SummitStack),80Gbps(VIM2-SummitStack-V80)or128Gbps(VIM2-SummitStack128)ofstackingbandwidth.High-speed128Gbpsstackingisidealfordemandingapplica-tionswhereahighvolumeoftraffictraversesthroughthestackinglinks,yetbandwidthisnotcompromisedthroughstacking.High-speedstackingisveryusefulinapplicationssuchastopofrackwhenstackedwithSummitX480andSummitX650(requiresoptionalconversioncable)andgigabitaggregationinlargeenterpriseordatacenternetworks.Withthelongerstackingcablessuchas5-meters,stackingcanbeconfiguredthroughdifferentrackshorizontallyinarow(seeFigure3)asopposedtotypicalstackingsysteminstalledverticallyinarack.
SummitStack-V – Flexible Stacking Over 10 Gigabit Ethernet SummitStack-Vcapabilityutilizes10GbEportsasstackingports,enablingtheuseofstandardcablingandopticstech-nologiesusedfor10GbEsuchasXFP,SFP+,10GBASE-TandXENPAK.SummitStack-Vprovideslong-distancestackingconnectivityofupto40kmwhilereducingthecablecomplexityofimplementingastackingsolution.SummitStack-Venabled10GbEportsmustbephysicallydirect-connected.SummitStack-ViscompatiblewithSummitX450e,X450a,X460,X480,X650,X670andX670VswitchesrunningthesameversionofExtremeXOS.
High-Performance Switching and Routing SummitX480isavailableinthreedifferentportconfigurationoptions:24-portGigabitEthernetand2-port10GigabitEthernet(SummitX480-24x),48-portcopperGigabitEthernet(SummitX480-48t),or48-portfiberGigabitEthernet(SummitX480-48x).Allfrontpanelportsrunatnon-blocking,wire-speedperformanceandcancarrywire-ratetraffictowardstheVersatileInterfaceModule-2(VIM2)slot.SummitX480offersflexibleconfigurationbyusingoptionalVIM2moduleswhichare:4-port10GigabitEthernetModule(VIM2-10G4X),2-portSummitStackModule(VIM2-SummitStack),2-portSummitStack128Module(VIM2-SummitStack128)or2-portSummitStack-V80Module(VIM2-SummitStack-V80)(seeFigure1:PortconfigurationoptionsforSummitX480switches).
Flexible Port ConfigurationSummitX480offersflexibleportconfigurationsfromstandardconfigurationtooptionalVIM2modules.ForSummitX480-24x,halfoftheGigabitEthernetportscanhandledualpersonality—selectfromeither10/100/1000BASE-TcopperGigabitEthernetor100/1000BASE-XfiberGigabitEthernetconnectivity.InthecaseofSummitX480-48t,thelastfourGigabitEthernetportsareconfiguredasdualpersonalityportstoprovideflexibilitybetweencopperandfiberGigabitEthernet.
ThroughtheVIM2slot,SummitX480canaddanadditionalfour10GigabitEthernetorSummitStackstackingports.Forstacking,dependingupontheneedsforbandwidthacrosstheunitsinastack,SummitX480supports40GbpsSummitStack,80GbpsSummitStack-V80or128GbpsSummitStack128throughVIM2optionmodules(SeeFigure2:SummitX480-24xflexibleportconfiguration).Athirdoption,SummitStack-V,utilizes10GbEportsasstackingports.
SummitX480supportsflexible10gigabitopticaltransceiverssuchas10GBASE-SR,LR,ERandZRaswellastunableDWDM.TunableDWDM(DenseWavelengthDivisionMultiplexing)supportallowsserviceprovidersandotherstotuneXFP10GigabitEthernetopticstoaspecificfrequency,reducingtheneedforadditionalfiberrunsandXFPsparing.DigitalDiagnosticsMonitoringInterfacesupportallowsserviceprovid-erstomonitoranddiagnosepluggableopticsinreal-time.
3
Extreme Networks Data Sheet: Summit X480 Series
High-Performance and Highly Scalable Switching and Routing
VIM Options None (default option) VIM2-10G4X VIM2-SummitStack VIM2-SummitStack-V80 VIM2-SummitStack128
Summit X480-24x • 24x100/1000BASE-X(SFP)
• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)
• 2x10GBASE-X(XFP)
• 24x100/1000BASE-X(SFP)
• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)
• 6x10GBASE-X(XFP)
• 24x100/1000BASE-X(SFP)
• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)
• 2x10GBASE-X(XFP)• 2xSummitStack
• 24x100/1000BASE-X(SFP)
• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)
• 2x10GBASE-X(XFP)• 2xSummitStack-V80
• 24x100/1000BASE-X(SFP)
• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)
• 2x10GBASE-X(XFP)• 2xSummitStack128
Summit X480-48t • 48x10/100/1000BASE-T• 4x100/1000BASE-X
SFP(sharedwiththelast410/100/1000BASE-Tports)
• 48x10/100/1000BASE-T• 4x100/1000BASE-X
SFP(sharedwiththelast410/100/1000BASE-Tports)
• 4x10GBASE-X(XFP)
• 48x10/100/1000BASE-T• 4x100/1000BASE-X
SFP(sharedwiththelast410/100/1000BASE-Tports)
• 2xSummitStack
• 48x10/100/1000BASE-T• 4x100/1000BASE-X
SFP(sharedwiththelast410/100/1000BASE-Tports)
• 2xSummitStack-V80
• 48x10/100/1000BASE-T• 4x100/1000BASE-X
SFP(sharedwiththelast410/100/1000BASE-Tports)
• 2xSummitStack128
Summit X480-48x • 48x100/1000BASE-XSFP
• 48x100/1000BASE-XSFP
• 4x10GBASE-X(XFP)
• 48x100/1000BASE-XSFP
• 2xSummitStack
• 48x100/1000BASE-XSFP
• 2xSummitStack-V80
• 48x100/1000BASE-XSFP
• 2xSummitStack128
Figure 1: Port Configuration Options for Summit X480 Switches
Figure 3: SummitStack Across Racks in a Row
5391-03
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server
Save Power, Cost and SpaceSummit® X480 provides virtualized end-of-row switches by physically installing top-of-rack switches with a 128G stacking module.
Figure 2: Summit X480-24x Flexible Port Configuration
12x100/1000BASE-X 2-port10GBSE-XXFP12x100/1000BASE-Xor12x10/100/1000BASE-T
4
Extreme Networks Data Sheet: Summit X480 Series
High-Performance and Highly Scalable Switching and Routing
High Scalability in 1RU Compact Switch
SummitX480supportshighlyscalableLayer2orLayer3networks,aswellashighlysecurenetworks.SummitX480hasexpansionmemorycalledTCAMbuiltinsidewhichcanbepartitionedbyapplicationtypesorbydeploymentscenarios.ForlargerLayer2networkdeployments,SummitX480can
supportupto512KMACaddresses.SimilarlyforlargerLayer3routingenvironments,SummitX480cansupportcoreroutingclassscalabilityforupto512KIPv4routingLPMentriesinhardware(SeeFigure4:SummitX480scalability).
Supports Virtualized Data Centers
SummitX480switchesalsosupportDirectAttach™,whicheliminatesthevirtualswitchlayer,simplifyingthenetworkandimprovingperformance.DirectAttachenablesdatacentersimplificationbyreducingnetworktiersfrom4or5tierstojust3or2tiers,dependingonthesizeofthedatacenter.Tofurtherenhancedatacenteroperations,SummitX480switches
supportXNV™(ExtremeXOSNetworkVirtualization),asetofsoftwaremodulesfortheExtremeXOSbasedswitchingproductportfolio,andavailableviatheDataCenterFeaturePackforExtremeNetworksRidgeline™,anetworkandservicemanagementapplication.XNVbringsinsight,controlandautomationforhighlyvirtualizeddatacenterstothenetwork.
Type L2 MAC L3 Host (IPv4/v6)
L3 LPM Route (IPv4/v6)
ACL(Ingress/Egress)
Lower Power Mode 32K 16K/8K 16K/8K 8K/1K
Default (Layer 2+Layer 3) 256K 16K/8K 256K/8K 8K/1K
Large Layer 2 Network Configuration 512K 16K/8K 16K/8K 8K/1K
Large Layer 3 Network Configuration 32K 16K/8K 512K/8K 8K/1K
Security Configuration 32K 16K/8K 16K/8K 60K/1K
Figure 4: Summit X480 Scalability
5
Extreme Networks Data Sheet: Summit X480 Series
High-Performance and Highly Scalable Switching and Routing
Figure 5: Summit X480 in a Carrier Ethernet Application
5392-03
Subscriber Access WAN CoreMetroContent and
Service Providers
Mobile
Private Data
Video
Voice
Public IP
Mobile Data
Mobile Video
IPTV
VOD
E-LAN
E-Line
Residential
Fixed• DSL• TDM• CMTS• PON• FTTX
Wireless• Mobile• LTE• WiMAX
Business
Mobile
Roaming
Metro Ethernet TransportIP Services IP ServicesMPLS
Core Router
Core Router
Metro Core
BlackDiamond®
8810 with 8900-xlSeries Modules
MetroAggregation
Summit X480
MetroAggregation
Summit X480
MetroAggregation
Summit® X480
1 GbE 10 GbE
96-port 10/100/1000BASE-T, MPU21
96-port 10/100/1000BASE-T, MPU21
Intelligent Switching and MPLS/ H-VPLS Support
SummitX480supportssophisticatedandintelligentLayer2switching,aswellasLayer3IPv4/IPv6routingincludingpolicy-basedswitching/routing,ProviderBridges,bidirectionalingressandegressAccessControlLists,andbandwidthcontrolby8Kbpsgranularitybothforingressandegress.ToprovidescalablenetworkarchitecturesusedmainlyforCarrierEthernetnetworkdeployment,throughafeaturepackSummitX480
supportsMPLSLSPbasedLayer3forwardingandHierarchicalVPLS(H-VPLS)fortransparentLANservices.WithH-VPLS,transparentLayer3networkscanbeextendedthroughouttheLayer3networkcloudbyusingaVPLStunnelbetweentheregionaltransparentLANservicestypicallybuiltbyProviderBridges(IEEE802.1ad)technology(seeFigure5:SummitX480inaCarrierEthernetapplication).
6
Extreme Networks Data Sheet: Summit X480 Series
High Availability Powered by the ExtremeXOS OS, Summit X480 supports process recovery and application upgrades without the need for a system reboot. Summit X480 provides the high network availability required for mission-critical servers and applications through its advanced modular OS, highly available hardware architecture and carrier-grade network redundancy protocols.
Software-Enhanced AvailabilitySoftware-enhancedavailabilityallowsuserstoremaincon-nectedtothenetworkevenifpartofthenetworkinfrastructureisdown.SummitX480continuouslychecksforproblemsintheuplinkconnectionsusingadvancedLayer3protocolssuchasOSPF,VRRPandExtremeStandbyRouterProtocol™(ESRP,supportedinLayer2orLayer3),anddynamicallyroutestrafficaroundtheproblem.
Equal Cost MultipathEqualCostMultipath(ECMP)routingallowsuplinkstobeloadbalancedforperformanceandcostsavingswhilealsosupport-ingredundantfailover.Ifanuplinkfails,trafficisautomaticallyroutedtotheremaininguplinksandconnectivityismaintained.
Link Aggregation (802.3ad)Linkaggregation(LAG)allowstrunkingofuptoeightlinksonasinglelogicalconnection.Amaximumof128linkaggregationgroupscanbecreated.
Multi-Switch LAG (M-LAG)M-LAGcanaddressbandwidthlimitationsandimprovenetworkresiliency,inpartbyroutingnetworktrafficaroundbottlenecks,reducingtherisksofasinglepointoffailure,andallowingloadbalancingacrossmultipleswitches.
Voice-Grade Stacking with SummitStackAllSummitStackstackingarchitectureisdesignedtosupportmission-criticalapplicationsbyitshighlyavailable,rapidfailovercapabilitywithn-1masterredundancy,distributedLayer2andLayer3switching,linkaggregationacrossthestack,anddistributeduplinks.SummitStacksupportsuptoeightunitsinastack,includinganymixofSummitX650,X480,X460,X450a,X450eandX250erunningthesameversionofExtremeXOSandprovides50millisecondsfailoverforpathfailureandhitlessmaster/backupfailoveralongwithhitlessprotocolsupportsuchasOSPFgracefulrestartandNetworkLoginuserauthentication.
Modular Operating System for Continuous Operation
Preemptive Multitasking and Protected MemorySummitX480seriesswitchesalloweachofmanyapplica-tions—suchasOpenShortestPathFirst(OSPF)andSpanningTreeProtocol(STP)—torunasseparateOSprocessesthatareprotectedfromeachother.ThisdrivesincreasedsystemintegrityandinherentlyprotectsagainstDoSattacks.
Process Monitoring and RestartExtremeXOSincreasesnetworkavailabilityusingprocessmonitoringandrestart.EachindependentOSprocessismonitoredinrealtime.Ifaprocessbecomesunresponsiveorstopsrunning,itcanbeautomaticallyrestarted.
Loadable Software ModulesThemodulardesignofExtremeXOSOSallowstheupgradingofindividualsoftwaremodules,shouldthisbenecessary,leadingtohigheravailabilityinthenetwork(SeeFigure7:ExtremeXOSmodulardesign).
High Availability Network Protocols
Ethernet Automatic Protection Switching (EAPS)EAPSallowstheIPnetworktoprovidethelevelofresiliencyanduptimethatusersexpectfromtheirtraditionalvoicenetwork.EAPSismoreadaptablethanSpanningTreeorRapidSpanningTreeProtocolsandofferssub-second(lessthan50milliseconds)recoverythatdeliversconsistentfailoverregard-lessofthenumberofVLANs,networknodesornetworktopology.SinceEAPSallowsthenetworktorecoveralmosttransparently,Voice-over-IP(VoIP)callswillnotdropanddigitalvideofeedswillnotfreezeorpixelizeinmostsituations.
Spanning Tree/Rapid Spanning Tree ProtocolsSummitX480supportsSpanningTree(802.1D),PerVLANSpanningTree(PVST+),RapidSpanningTree(802.1w)andMultipleInstancesofSpanningTree(802.1s)protocolsforLayer2resiliency.
7
Extreme Networks Data Sheet: Summit X480 Series
High Availability
SummitX480provideschassis-likemanagementandavailabilitywithitsSummitStackstackingtechnology(SeeFigure8:SummitStackstackingarchitecture).
Hardware RedundancySummitX480supportsadualredundantAC/DCpowersupplytoprovidehighavailability.Thepowersupplycanbehot-swappedandreplacedshoulditfail.SummitX480supportsahot-swappable,fieldreplaceablefan.
Alternatively,youmaychoosehigh-speed80Gbpsstacking,whichisidealfordemandingapplicationswhereahighvolumeoftraffictraversesthroughthestackinglinks,yetbandwidthisnotcompromisedthroughstacking.SummitStack-V80alsobreaksthedistancelimitationforstackingtechnologybyusingQSFP+technology.SummitStack-V80cansupportpassivecoppercable(upto5m),activemulti-modefibercable(upto100m),andQSFP+opticaltransceiverswhichwillbethestandardtechnologyfor40GbE.WithSummitStack-V80,theSummitX460providesaflexiblestackingsolutioninsidethedatacenterorcentralofficetocreateavirtualizedswitchinginfrastructureacrossrowsofracks.SummitStack-V80iscompatiblewithSummitX460,X480andX670VswitchesrunningthesameversionofExtremeXOS.
Figure 6: Summit X480 High Availability Design4-port10GXFP SummitStack-V80SummitStack128G
VIM2SlotRemovableFan
(Hot-SwappablewithSummitX480) RedundantHot-SwappableAC/DCPSU
SummitStack40G
5027-04
• Processes are monitored and can be restarted or other action taken if necessary
• Hitless failover infrastructure for dual management systems and stacking
BGP OSPF SSH-2 V1.3.1
SSH-2 V1.3.2
ThirdParty
Application
ExtremeXOSKernel
Kernel LoadableModule
Memory protected processes under
real-time scheduling that cannot impact each other nor
kernel
1Designed to allow
application modules to be
upgraded during runtime
3
Application modules can be added during
runtime
2
5389-05
• Single management point for up to eight units• High-speed 40G–128G stacking• Rapid Failover for converged applications• Can mix Summit X650, X480, X460, X450e, X450a, and X250e series switches for SummitStack™ 40 Gbps stacking
Figure 7: ExtremeXOS Modular Design Figure 8: SummitStack Stacking Architecture
8
Extreme Networks Data Sheet: Summit X480 Series
Comprehensive Security Management Implementing a secure network means providing protection at the network perimeter as well as the core. Summit X480 uses advanced security functions in protecting your network from known or potential threats.
communicatewithotherportsinthesameVLANoverLayer2orLayer3.PrivateVLANportscanonlycommunicatewithadesignated“uplink”port.Inaddition,aPrivateVLANprovidesseparationofbroadcastdomainswithinthesameVLAN.
Threat Detection and Response
CLEAR-Flow Security Rules EngineCLEAR-Flowprovidesfirstorderthreatdetectionandmitiga-tion,andmirrorstraffictoappliancesforfurtheranalysisofsuspicioustrafficinthenetwork.
Protocol Anomaly DetectionTheExtremeNetworkschipsetscontainbuilt-inhardwareprotocolcheckersthatsupportportsecurityfeaturesforsecurityapplications,suchasstatelessDoSprotection.Theprotocolcheckersallowuserstodropthepacketsbasedonconditions,whicharecheckedforingresspacketspriortotheLayer2/Layer3entrytable.
sFlowsFlow®isasamplingtechnologythatprovidestheabilitytosampleapplication-leveltrafficflowsonallinterfacessimultaneously.
IPFIXIPFIX(InternetProtocolFlowInformationeXport)definesanInternetstandards-trackprotocolforafollow-onprotocoltotheproprietaryNetflow.ThetechnologyisacomplementaryprotocoltosFlow.IPFIXgathersinformationaboutnetworkflowsthroughtheswitchandsendstheinformationtoanexternalcollector.SummitX480includeshardwaresupporttokeeptrackoftheflowrecords.
Port MirroringSummitX480supportsmany-to-oneandone-to-manyportmirroring.Thisallowsthemirroringoftraffictoanexternalnetworkappliancesuchasanintrusiondetectiondevicefortrendanalysisorforutilizationbyanetworkadministratorfordiagnosticpurposes.Portmirroringcanalsobeenabledacrossswitchesinastack.
Robust IP and MAC Security Framework
NetLoginNetworkLoginprovidesthreetypesofauthentication—Web-based,MAC-based,and802.1x—toproperlyauthenticatenetworkusersagainstRADIUSservers.WhencombinedwithExtremeNetworksUniversalPortManager(UPM),ITadminis-tratorscandynamicallyprovisionpoliciestoassociatednetworkusersbasedonrolesorUPMprofiles.
Media Access Control (MAC) SecurityMACsecurityallowsthelockdownofaporttoagivenMACaddressandlimitingthenumberofMACaddressesonaport.Thiscanbeusedtodedicateportstospecifichostsordevicesandavoidabuseoftheport.Inaddition,anagingtimercanbeconfiguredfortheMAClockdown,protectingthenetworkfromtheeffectsofattacksusing(oftenrapidly)changingMACaddresses.
IP SecurityExtremeXOSIPsecurityframeworkprotectsthenetworkinfrastructure,networkservicesandhostcomputersfromrogueaccess,spoofingandman-in-the-middleattacks.Italsoprotectsthenetworkfromstaticallyconfiguredand/orspoofedIPaddressesandbuildsanexternaltrusteddatabaseofMAC/IP/portbindingsprovidingthetraffic’ssourcefromaspecificaddressforimmediatedefense.
Identity ManagerIdentityManagerallowsnetworkmanagerstotrackuserswhoaccesstheirnetwork.UseridentityiscapturedbasedonNetLoginauthentication,LLDPdiscoveryandKerberossnooping.ExtremeXOSusestheinformationtothenreportontheMAC,VLAN,computerhostname,andportlocationoftheuser.Further,IdentityManagercancreatebothrolesandpolicies,andthenbindthemtogethertocreaterole-basedprofilesbasedonorganizationalstructureorotherlogicalgroupings,andapplythemacrossmultipleuserstoallowappropriateaccesstonetworkresources.
Private VLANsPrivateVLANsprovideport-to-portsecuritytopreventunauthorizedcommunicationofuserswithinthesameVLAN.UnlikenormalVLANs,portsenabledforPrivateVLANscannot
9
Extreme Networks Data Sheet: Summit X480 Series
Comprehensive Security Management
ExtremeNetworkshasdevelopedtoolsthatsimplifyandhelpinefficientlymanagingyournetwork.Ridgelinenetworkandservicemanagementprovidesfault,configuration,accounting,performanceandsecurityfunctions,allowingmoreeffectivemanagementofExtremeNetworksproducts,solutionsandthird-partydevices,inaconvergednetwork.
Forcarriernetworks,Ridgelineenablestheshiftfromreactivecircuitmonitoringtoproactiveservicemanagement.ThekeyfeaturesintegratedintotheServiceAdvisorFeaturePackunifyservicefulfillment,serviceassuranceandserviceengineeringtoenablecarrierstomoreeffectivelymanagenext-generationresidentialtripleplay,businessEthernetandEthernetmobilebackhaulservices.
Line-Rate ACLsACLsareoneofthemostpowerfulcomponentsusedincontrollingnetworkresourceutilizationaswellasprotectingthenetwork.ACLsareusedforfilteringthetraffic,aswellasclassifyingthetrafficflowtocontrolbandwidth,priority,mirroring,andpolicy-basedrouting/switching.
Denial of Service ProtectionSummitX480effectivelyhandlesDenialofService(DoS)attacks.IftheswitchdetectsanunusuallylargenumberofpacketsintheCPUinputqueue,itassemblesACLsthatautomaticallystopthesepacketsfromreachingtheCPU.Afteraperiodoftime,theseACLsareremoved,andreinstallediftheattackcontinues.
Secure and Comprehensive Network ManagementSummitX480supportscomprehensivenetworkmanagementthroughCommandLineInterface(CLI),SNMPv1,v2c,v3,andExtremeXOSScreenPlay™embeddedXML-basedWebuserinterface.Withavarietyofmanagementoptionsandconsis-tencyacrossotherExtremeNetworksmodularandstackableswitches,SummitX480seriesswitchesprovideeaseofmanagementfordemandingconvergedapplications.
10
Extreme Networks Data Sheet: Summit X480 Series
Target Applications
Top-of-Rack Switch for Servers in the Enterprise Data Centers Intheenterprisedatacenter,manyserversandstoragesystemsarepackedinracks,withallsystemsneedinghigh-speedconnectivity.Atop-of-rackarchitectureisonewaytosimplifythecablinginfrastructureandminimizethespacerequirementsintheenterprisedatacenter.SummitX480isoptimizedtosupporthigh-densityGigabitEthernetconnectivityforserversandothernetwork-attacheddevicesandprovideshigh-speed80Gbpsor128GbpsstackingconnectivitywiththeSummitX65010GigabitEthernetswitchtoprovidethehybriddeploymentforbothgigabitand10gigabitenabledserversinthedatacenters.
High-Performance 10 Gigabit Core Switch for a Small Network and Aggregation Switch in a Traditional Three-Tiered Network SummitX480offersenterprisecore-classscalabilityforbothLayer2andLayer3switching.SummitX480cansupportupto512,000Layer2MACaddressesor512,000IPv4longestprefixmatchingroutes.TheSummitX480switchcanalsobeusedinthenetworkaggregationlayerinanenterprisenetwork.Withitsversatiledesign,SummitX480canhelpsimplifyenterprisenetworkdeployment.
5390-03
BlackDiamond®
8810BlackDiamond
8810
Core Layer
Access LayerTop of the Rack
Summit® X480 Summit X650 Summit X480 Summit X650 Summit X480 Summit X650
CampusNetwork
ServerRack
ServerRack
ServerRack
ServerRack
ServerRack
ServerRack
Figure 9: Top-of-Rack Architecture with Hybrid Deployment
5393-03
Summit X480
Summit X480
Summit X480
Summit X480
Summit X460Summit® X460
5394-03
Summit X450e
Summit X480Summit® X480
Summit X460Summit X450eSummit X460
Network Core
Figure 10: High-Performance 10G Core Switch
Figure 11: Summit X480 as an Aggregation Switch in a Three-Tier Network
11
Extreme Networks Data Sheet: Summit X480 Series
Target Applications
Carrier Ethernet Network Switch that can Aggregate Connectivity for First Mile Access Concentrators SummitX480isanidealservicedeliveryplatformforCarrierEthernetnetworks.Theadvancedtrafficmanagement,resiliencyandscalabilityfeaturesgiveittheflexibilitytobedeployedattheProviderEdgeorasanaggregationswitch.BysupportinghighlyscalableLayer2andLayer3featuresalongwithMPLS/H-VPLSinhardware,SummitX480canhelpsimplifythenetworkdeployment.
5392-03
Subscriber Access WAN CoreMetroContent and
Service Providers
Mobile
Private Data
Video
Voice
Public IP
Mobile Data
Mobile Video
IPTV
VOD
E-LAN
E-Line
Residential
Fixed• DSL• TDM• CMTS• PON• FTTX
Wireless• Mobile• LTE• WiMAX
Business
Mobile
Roaming
Metro Ethernet TransportIP Services IP ServicesMPLS
Core Router
Core Router
Metro Core
BlackDiamond®
8810 with 8900-xlSeries Modules
MetroAggregation
Summit X480
MetroAggregation
Summit X480
MetroAggregation
Summit® X480
1 GbE 10 GbE
96-port 10/100/1000BASE-T, MPU21
96-port 10/100/1000BASE-T, MPU21
Figure 12: Summit X480 in a Carrier Ethernet Application
12
Extreme Networks Data Sheet: Summit X480 Series
Technical Specifications
ExtremeXOS 12.5 Supported Protocols
Switching • Switching(EAPS)andEAPSv2• IEEE802.1D–1998SpanningTreeProtocol(STP)
• IEEE802.1D–2004SpanningTreeProtocol(STPandRSTP)
• IEEE802.1w–2001RapidReconfigurationforSTP,RSTP
• IEEE802.1Q–2003(formerlyIEEE802.1s)MultipleInstancesofSTP,MSTP
• EMISTP,ExtremeMultipleInstancesofSpanningTreeProtocol
• PVST+,PerVLANSTP(802.1Qinteroperable)• Draft-ietf-bridge-rstpmib-03.txt–DefinitionsofManagedObjectsforBridgeswithRapidSpanningTreeProtocol
• ExtremeStandbyRouterProtocol(ESRP)• IEEE802.1Q–1998VirtualBridgedLocalAreaNetworks
• IEEE802.3adStaticloadsharingconfigura-tionandLACPbaseddynamicconfiguration
• SoftwareRedundantPorts• Multi-switchLinkAggregationGroups(M-LAG)
• IEEE802.1AB–LLDPLinkLayerDiscoveryProtocol
• LLDPMediaEndpointDiscovery(LLDP-MED),ANSI/TIA-1057,draft08
• ExtremeDiscoveryProtocol(EDP)• ExtremeLoopRecoveryProtocol(ELRP)• ExtremeLinkStateMonitoring(ELSM)• IEEE802.1agL2Pingandtraceroute,ConnectivityFaultManagement
• ITU-TY.1731Framedelaymeasurements
Management and Traffic Analysis • RFC2030SNTP,SimpleNetworkTimeProtocolv4
• RFC854Telnetclientandserver• RFC783TFTPProtocol(revision2)• RFC951,1542BootP• RFC2131BOOTP/DHCPrelayagentandDHCPserver
• RFC1591DNS(clientoperation)• RFC1155StructureofManagementInformation(SMIv1)
• RFC1157SNMPv1• RFC1212,RFC1213,RFC1215MIB-II,Ethernet-LikeMIB&TRAPs
• RFC1573EvolutionofInterface• RFC1650Ethernet-LikeMIB(updateofRFC1213forSNMPv2)
• RFC1901,1905–1908SNMPv2c,SMIv2andRevisedMIB-II
• RFC2576CoexistencebetweenSNMPVersion1,Version2andVersion3
• RFC2578–2580SMIv2(updatetoRFC1902–1903)
• RFC3410–3415SNMPv3,userbasedsecurity,encryptionandauthentication
• RFC3826–TheAdvancedEncryptionStandard(AES)CipherAlgorithmintheSNMPUser-basedSecurityModel
• RFC1757RMON4groups:Stats,History,AlarmsandEvents
• RFC2021RMON2(probeconfiguration)• RFC2613SMONMIB• RFC2925Ping/TracerouteMIB• RFC2668802.3MAUMIB• draft-ietf-hubmib-mau-mib-v3-02.txt• RFC1643EthernetMIB• RFC1493BridgeMIB• RFC2096IPv4ForwardingTableMIB• RFC2737EntityMIBv2• RFC2233InterfaceMIB• RFC3621PoE-MIB(PoEswitchesonly)• IEEE802.1agMIB• SecureShell(SSH-2)clientandserver• SecureCopy(SCP-2)clientandserver• SecureFTP(SFTP)server• sFlowversion5• RFC3917IPFIX• Configurationlogging• MultipleImages,MultipleConfigs• RFC3164BSDSyslogProtocolwithMultipleSyslogServers– 999LocalMessages(criticalsstoredacrossreboots)
• ExtremeNetworksvendorMIBs(includesFDB,PoE,CPU,MemoryMIBs)
• XMLAPIsoverTelnet/SSHandHTTP/HTTPS• Web-baseddevicemanagementinterface–ExtremeXOSScreenPlay™
• IPRouteCompression• SFF-8472DDMI(DigitalDiagnosticsMonitoringInterface)
• Stacking–SummitStack,SummitStack-VandSummitStack128
Security, Switch and Network Protection • SecureShell(SSH-2),SecureCopy(SCP-2)andSFTPclient/serverwithencryption/authentication(requiresexportcontrolledencryptionmodule)
• SNMPv3userbasedsecurity,withencryption/authentication(seeabove)
• RFC1492TACACS+• RFC2138RADIUSAuthentication• RFC2139RADIUSAccounting• RFC3579RADIUSEAPsupportfor802.1x• RADIUSPer-commandAuthentication• AccessProfilesonAllRoutingProtocols• AccessPoliciesforTelnet/SSH-2/SCP-2• NetworkLogin–802.1x,WebandMAC-basedmechanisms
• IEEE802.1x–2001Port-BasedNetworkAccessControlforNetworkLogin
• MultiplesupplicantswithmultipleVLANsforNetworkLogin(allmodes)
• Fallbacktolocalauthenticationdatabase(MACandWeb-basedmethods)
• GuestVLANfor802.1x• RFC1866HTML–UsedforWeb-basedNet-workLoginandExtremeXOSScreenPlay
• SSL/TLStransport–usedforWeb-basedNetworkLoginandExtremeXOSScreen-Play(requiresexportcontrolledencryptionmodule)
• MACSecurity–LockdownandLimit• IPSecurity–RFC3046DHCPOption82withportandVLANID
• IPSecurity–TrustedDHCPServer• Layer2/3/4AccessControlLists(ACLs)• RFC2267NetworkIngressFiltering
• RPF(UnicastReversePathForwarding)ControlviaACLs
• Wire-speedACLs• RateLimiting/ShapingbyACLs• IPBroadcastForwardingControl• ICMPandIP-OptionResponseControl• SYNattackprotection• CPUDoSProtectionwithtrafficrate-limitingtomanagementCPU
• Robustagainstcommonnetworkattacks:– CERT(http://www.cert.org)– CA-2003-04:“SQLSlammer”– CA-2002-36:“SSHredder”– CA-2002-03:SNMPvulnerabilities– CA-98-13:tcp-denial-of-service– CA-98.01:smurf– CA-97.28:Teardrop_Land-Teardropand“LAND“attack– CA-96.26:ping– CA-96.21:tcp_syn_flooding– CA-96.01:UDP_service_denial– CA-95.01:IP_Spoofing_Attacks_and_Hijacked_Terminal_Connections– IPOptionsAttack
• HostAttackProtection– Teardrop,boink,opentear,jolt2,newtear,nestea,syndrop,smurf,fraggle,papasmurf,synk4,raped,winfreeze,ping–f,pingofdeath,pepsi5,Latierra,Winnuke,Simping,Sping,Ascend,Stream,Land,Octopus
Security, Router Protection• IPSecurity–DHCPenforcementviaDisableARPLearning
• IPSecurity–GratuitousARPProtection• IPSecurity–DHCPSecuredARP/ARPValidation
• RoutingprotocolMD5authentication
Security Detection and Protection• CLEAR-Flow,threshold-basedalertsandactions(in non-SummitStack configuration only)
• IdentityManager
IPv4 Host Services• RFC1122HostRequirements• RFC768UDP• RFC791IP• RFC792ICMP• RFC793TCP• RFC826ARP• RFC894IPoverEthernet• RFC1027ProxyARP• RFC2068HTTPserver• IGMPv1/v2/v3SnoopingwithConfigurableRouterRegistrationForwarding
• IGMPFilters• PIMSnooping• StaticIGMPMembership• MulticastVLANRegistration(MVR)
IPv4 Router Services• RFC1812RequirementsforIPVersion4Routers
• RFC1519CIDR• RFC1256IPv4ICMPRouterDiscovery(IRDP)• StaticUnicastRoutes• StaticMulticastRoutes
13
Extreme Networks Data Sheet: Summit X480 Series
• RFC1058RIPv1• RFC2453RIPv2• StaticECMP• RFC1112IGMPv1• RFC2236IGMPv2• RFC3376IGMPv3• RFC2933IGMPMIB• RFC2096IPv4ForwardingTableMIB• RFC1724RIPv2MIB• RFC3768VRRPv2• RFC2787VRRPMIB• RFC2328OSPFv2(Edge-mode)• OSPFECMP• OSPFMD5Authentication• RFC1587OSPFNSSAOption• RFC1765OSPFDatabaseOverflow• RFC2370OSPFOpaqueLSAOption• RFC3623OSPFGracefulRestart• RFC1850OSPFv2MIB• RFC2362PIM-SM(Edge-mode)• RFC2934PIMMIB• RFC3569,draft-ietf-ssm-arch-06.txtPIM-SSMPIMSourceSpecificMulticast
• draft-ietf-pim-mib-v2-o1.txt• Mtrace,a“traceroute”facilityforIPMulticast:draft-ietf-idmr-traceroute-ipm-07
• Mrinfo,themulticastrouterinformationtoolbasedonAppendix-Bofdraft-ietf-idmr-dvmrp-v3-11
IPv6 Host Services• RFC3587,GlobalUnicastAddressFormat• PingoverIPv6transport• TracerouteoverIPv6transport• RFC5095,InternetProtocol,Version6(IPv6)Specification
• RFC4861,NeighborDiscoveryforIPVersion6,(IPv6)
• RFC2463,InternetControlMessageProtocol(ICMPv6)fortheIPv6Specification
• RFC2464,TransmissionofIPv6PacketsoverEthernetNetworks
• RFC2465,IPv6MIB,GeneralGroupandTextualConventions
• RFC2466,MIBforICMPv6• RFC2462,IPv6StatelessAddressAutoConfiguration–HostRequirements
• RFC1981,PathMTUDiscoveryforIPv6,August1996–HostRequirements
• RFC3513,InternetProtocolVersion6(IPv6)AddressingArchitecture
• TelnetserveroverIPv6transport• SSH-2serveroverIPv6transport
IPv6 Interworking and Migration• RFC2893,ConfiguredTunnels• RFC3056,6to4
IPv6 Router Services • RFC2462,IPv6StatelessAddressAutoConfiguration–RouterRequirements
• RFC1981,PathMTUDiscoveryforIPv6,August1996–RouterRequirements
• RFC2710,IPv6MulticastListenerDiscoveryv1(MLDv1)Protocol
• StaticUnicastroutesforIPv6• RFC2080,RIPng• RFC2740OSPFv3(edgemode)• StaticECMP
Core Protocols for Layer 2, IPv4 and IPv6 Requires Core License
• EAPSv2SharedPorts–multipleinterconnectionsbetweenrings
• PIM-DMDraftIETFPIMDenseModedraft-ietf-idmr-pim-dm-05.txt,draft-ietf-pim-dm-new-v2-04.txt
• RFC3618MulticastSourceDiscoveryProtocol(MSDP)
• RFC3446AnycastRPusingPIMandMSDP• RFC2740OSPFv3,OSPFforIPv6• RFC1771BorderGatewayProtocol4• RFC1965AutonomousSystemConfedera-tionsforBGP
• RFC2796BGPRouteReflection(supersedesRFC1966)
• RFC1997BGPCommunitiesAttribute• RFC1745BGP4/IDRPforIP-OSPFInteraction• RFC2385TCPMD5AuthenticationforBGPv4• RFC2439BGPRouteFlapDamping• RFC2918RouteRefreshCapabilityforBGP-4• RFC3392CapabilitiesAdvertisementwithBGP-4
• RFC4360BGPExtendedCommunitiesAttribute
• RFC4486SubcodesforBGPCeaseNotificationmessage
• draft-ietf-idr-restart-10.txtGracefulRestartMechanismforBGP
• RFC4760MultiprotocolextensionsforBGP-4• RFC1657BGP-4MIB• RFC4893BGPSupportforFour-OctetASNumberSpace
• Draft-ietf-idr-bgp4-mibv2-02.txt–EnhancedBGP-4MIB
• RFC1195UseofOSIIS-ISforRoutinginTCP/IPandDualEnvironments(TCP/IPtransportonly)
• RFC2763DynamicHostnameExchangeMechanismforIS-IS
• RFC2966Domain-widePrefixDistributionwithTwo-LevelIS-IS
• RFC2973IS-ISMeshGroups• RFC3373Three-wayHandshakeforIS-ISPoint-to-PointAdjacencies
• Draft-ietf-isis-restart-02RestartSignalingforIS-IS
• Draft-ietf-isis-ipv6-06RoutingIPv6withIS-IS• Draft-ietf-isis-wg-multi-topology-11MultiTopology(MT)RoutinginIS-IS
QoS and VLAN ServicesQuality of Service and Policies• IEEE802.1D–1998(802.1p)PacketPriority• RFC2474DiffServPrecedence,including8queues/port
• RFC2598DiffServExpeditedForwarding(EF)• RFC2597DiffServAssuredForwarding(AF)• RFC2475DiffServCoreandEdgeRouterFunctions
Traffic Engineering • RFC3784IS-ISExternsforTrafficEngineer-ing(widemetricsonly)
VLAN Services: VLANs, vMANs • IEEE802.1QVLANTagging• IEEE802.1v:VLANclassificationbyProtocolandPort
• Port-basedVLANs• Protocol-basedVLANs
• MAC-basedVLANs• MultipleSTPdomainsperVLAN• UpstreamForwardingOnly/DisableFlooding• RFC5517PrivateVLANs• VLANTranslation• IEEE802.1adProviderBridgeNetwork,virtualMANs(vMANs)
• vMANEthertypeTranslation/SecondaryvMANEthertype
• MulticastSupportforPVLAN• MulticastSupportforVLANAggregation• VLANAggregation
MPLS and VPN ServicesMulti-Protocol Label Switching (MPLS)Requires MPLS Feature Pack License
• RFC2961RSVPRefreshOverheadReductionExtensions
• RFC3031MultiprotocolLabelSwitchingArchitecture
• RFC3032MPLSLabelStackEncoding• RFC3036LabelDistributionProtocol(LDP)• RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnels
• RFC3630TrafficEngineeringExtensionstoOSPFv2
• RFC3811DefinitionsofTextualConventions(TCs)forMultiprotocolLabelSwitching(MPLS)Management
• RFC3812MultiprotocolLabelSwitching(MPLS)TrafficEngineering(TE)Manage-mentInformationBase(MIB)
• RFC3813MultiprotocolLabelSwitching(MPLS)LabelSwitchingRouter(LSR)ManagementInformationBase(MIB)
• RFC3815DefinitionsofManagedObjectsfortheMultiprotocolLabelSwitching(MPLS),LabelDistributionProtocol(LDP)
• RFC4090FastRe-routeExtensionstoRSVP-TEforLSP(DetourPaths)
• RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailures(LSPPing)
• draft-ietf-bfd-base-09.txtBidirectionalForwardingDetection
Layer 2 VPNsRequires MPLS Feature Pack License
• RFC4447PseudowireSetupandMaintenanceusingtheLabelDistributionProtocol(LDP)
• RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworks
• RFC4762VirtualPrivateLANServices(VPLS)usingLabelDistributionProtocol(LDP)Signaling
• RFC5085PseudowireVirtualCircuitConnectivityVerification(VCCV)
• RFC5542DefinitionsofTextualConventionsforPseudowire(PW)Management
• RFC5601Pseudowire(PW)ManagementInformationBase(MIB)
• RFC5602Pseudowire(PW)overMPLSPSNMIB
• RFC5603EthernetPseudowire(PW)MIB• draft-ietf-l2vpn-vpls-mib-02.txtVirtualPrivateLANServices(VPLS)MIB
Data Center• DirectAttach(IEEE802VEPA)(Supportedinafeaturepack)
• XNV(ExtremeXOSNetworkVirtualization)
Technical Specifications
14
Extreme Networks Data Sheet: Summit X480 Series
Summit X480
General Specifications Performance• 176Gbpsswitchfabricbandwidth• 224Gbps,448Gbps(withVIM2-10G4X)aggregatedswitchbandwidth
• 71.4Mpps,101.2Mpps(withVIM2-Summit-Stack),166.7Mpps(withVIM2-Summit-Stack128),130.9Mpps(withVIM2-10G4X)frameforwardingrate
• Lessthan4microsecondlatency(64-byte)• 9216Bytemaximumpacketsize(JumboFrame)
• 128loadsharingtrunks,upto8memberspertrunk
• 4,094VLANs(Port,Protocol,IEEE802.1Q)• 8,192ingressand1,024egressACLrules/Frontpanelportsand/VIM2-10G4Xmodule
CPU, Memory • 64bitMIPSProcessorDualCore,1GHzclock• 1GBECCDRAM• 256MBCompactFlash• USBportforexternalUSBflash
QoS, Rate Limiting • 8,192ingressbandwidthmeters/Frontpanelportsand/VIM2-10G4Xmodule
• Ingressandegressbandwidthpolicing/ratelimitingperflow/ACL
• 8QoSegressqueues/port• Egressbandwidthrateshapingperegressqueueandperport
• RateLimitingGranularity:8Kbps
LED Indicators• PerportstatusLEDincludingpowerstatus• SystemStatusLEDs:management,fanandpower
External Ports• 12-port100/1000BASE-XSFP,12-port100/1000BASE-XSFPand10/100/1000BASE-TCombo,2-port10GBASE-XXFP,1openslotforVIM2modules(SummitX480-24x)
• 44-port10/100/1000BASE-T,4-port100/1000BASE-XSFPand10/100/1000BASE-TCombo,1openslotforVIM2modules(SummitX480-48t)
• 48-port100/1000BASE-XSFP,1openslotforVIM2modules(SummitX480-48x)
• 1-portRS-232cSerial(controlport)• 110/100/1000BASE-Tout-of-bandmanagementport
External Ports for VIM2 Modules• 4-port10GBASE-XXFP(VIM2-10G4X)• 2-port20GSummitStack(VIM2-Summit-Stack)
• 2-port64GSummitStack(VIM2-SummitStack128)
Option Slot• SlotforVersatileInterfaceModule2(VIM2)availableforSummitX480-24x,SummitX480-48tandSummitX480-48x
Power Supply Support• SummitX480ACPSUandSummitX480DCPSU
Technical Specifications
Physical SpecificationsDimensions
Physical Dimensions • SummitX480-24xswitch• SummitX480-48xswitch• SummitX480-48tswitchHeight:1.73inches(4.4cm)Width:17.4inches(44.1cm)Depth:19.0inches(48.3cm)
• VIM2-SummitStackmodule• VIM2-10G4Xmodule• VIM2-SummitStack128moduleHeight:1.7inches(4.3cm)Width:5.2inches(13.2cm)Depth:9.9inches(25.2cm)
• SummitX480fanmoduleHeight:1.7inches(4.3cm)Width:5.2inches(13.2cm)Depth:9.9inches(25.2cm)
Weight• SummitX480-24xswitch20.9lb(9.5kg)• SummitX480-48xswitch22.7lb(10.3kg)• SummitX480-48tswitch21.2lb(9.6kg)
NOTE: Switch weights include installed fan module. They do not include installed VIM2 modules or PSUs.
• VIM2-SummitStackmodule2.03lb(0.92kg)• VIM2-10G4Xmodule2.76lb(1.25kg)• VIM2-SummitStack128module2.05lb(0.93kg)
• SummitX480fanmodule0.45lb(0.99kg)
Fan Speed• Minimumspeed4500RPM• Maximumspeed18000RPM
Operating Specifications• OperatingTemperatureRange:0°Cto45°C(32°Fto113°F)
• OperatingHumidity:10%to93%relativehumidity,non-condensing
• OperatingAltitude:0-3,000meters(9,850feet)
• OperationalShock(HalfSine):30m/s2(3g),11ms,60Shocks
• OperationalRandomVibration:3-500MHz@1.5grms
Storage & Transportation Conditions (Packaged)• TransportationTemperature:-40°Cto70°C(-40°Fto158°F)
• StorageandTransportationHumidity:10%to95%RH,non-condensing
• PackagedShock(HalfSine):180m/s2(18g),6ms,600shocks
• PackagedSineVibration:5-62Hz@Velocity5mm/s,62-500Hz@0.2G
• PackagedRandomVibration:5-20Hz@1.0ASDw/-3dB/oct.from20-200Hz
• 14dropsminonsides&corners@42”(<15kgbox)
Type L2 MAC L3 Host (IPv4/v6)
L3 LPM Route (IPv4/v6)
ACL(Ingress/Egress)
Lower Power Mode 32K 16K/8K 16K/8K 8K/1K
Default (Layer 2+Layer 3) 256K 16K/8K 256K/8K 8K/1K
Large Layer 2 Network Configuration 512K 16K/8K 16K/8K 8K/1K
Large Layer 3 Network Configuration 32K 16K/8K 512K/8K 8K/1K
Security Configuration 32K 16K/8K 16K/8K 60K/1K
Forwarding Tables and ACLsSummitX480providesflexibleconfigurationoptionsforvariousdeployments.
15
Extreme Networks Data Sheet: Summit X480 Series
Technical Specifications
Power Specifications
Summit X480-24xSummit X480-24x with No Installed VIM (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A
• Inputcurrent2.0A@100V(low-line)0.9A@240V(high-line)
• Heatdissipation,Watts,BTU195W,663BTU/hr
• Powerconsumption,Watts,BTU195W,663BTU/hr
Summit X480-24x with VIM2-SummitStack Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A
• Inputcurrent2.01A@100V(low-line)0.88A@240V(high-line)
• Heatdissipation,Watts,BTU200W,680BTU/hr
• Powerconsumption,Watts,BTU200W,680BTU/hr
Summit X480-24x with VIM2-10G4X Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A
• Inputcurrent2.4A@100V(low-line)1.1A@240V(high-line)
• Heatdissipation,Watts,BTU241W,823BTU/hr
• Powerconsumption,Watts,BTU241W,823BTU/hr
Summit X480-24x with VIM2-SummitStack128 Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A
• Inputcurrent2.08A@100V(low-line)0.91A@240V(high-line)
• Heatdissipation,Watts,BTU206W,704BTU/hr
• Powerconsumption,Watts,BTU206W,704BTU/hr
Summit X480-24x with No Installed VIM (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent3.25A@48V(low-line)2.6A@60V(high-line)
• Heatdissipation,Watts,BTU156W,532BTU/hr
• Powerconsumption,Watts,BTU156W,532BTU/hr
Summit X480-24x with VIM2-SummitStack Module (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent3.4A@48V(low-line)2.7A@60V(high-line)
• Heatdissipation,Watts,BTU161W,550BTU/hr
• Powerconsumption,Watts,BTU161W,550BTU/hr
Summit X480-24x with VIM2-10G4X Module (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent5.7A@48V(low-line)4.2A@60V(high-line)
• Heatdissipation,Watts,BTU246W,839BTU/hr
• Powerconsumption,Watts,BTU246W,839BTU/hr
Summit X480-24x with VIM2-SummitStack128 Module (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent3.5A@48V(low-line)2.8A@60V(high-line)
• Heatdissipation,Watts,BTU167W,569BTU/hr
• Powerconsumption,Watts,BTU167W,569BTU/hr
Summit X480-48xSummit X480-48x with No Installed VIM (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A
• Inputcurrent2.0A@100V(low-line)0.9A@240V(high-line)
• Heatdissipation,Watts,BTU200W,675BTU/hr
• Powerconsumption,Watts,BTU200W,675BTU/hr
Summit X480-48x with VIM2-SummitStack Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A
• Inputcurrent2.01A@100V(low-line)0.89A@240V(high-line)
• Heatdissipation,Watts,BTU203W,692BTU/hr
• Powerconsumption,Watts,BTU203W,692BTU/hr
Summit X480-48x with VIM2-10G4X Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A
• Inputcurrent2.3A@100V(low-line)1.0A@240V(high-line)
• Heatdissipation,Watts,BTU227W,774BTU/hr
• Powerconsumption,Watts,BTU227W,774BTU/hr
Summit X480-48x with VIM2-SummitStack128 Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A
• Inputcurrent2.04A@100V(low-line)0.89A@240V(high-line)
• Heatdissipation,Watts,BTU202W,688BTU/hr
• Powerconsumption,Watts,BTU202W,688BTU/hr
Summit X480-48x with No Installed VIM (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent3.3A@48V(low-line)2.6A@60V(high-line)
• Heatdissipation,Watts,BTU158W,540BTU/hr
• Powerconsumption,Watts,BTU158W,540BTU/hr
Summit X480-48x with VIM2-SummitStack Module (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent3.4A@48V(low-line)2.7A@60V(high-line)
• Heatdissipation,Watts,BTU163W,556BTU/hr
• Powerconsumption,Watts,BTU163W,556BTU/hr
Summit X480-48x with VIM2-10G4X Module (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent5.7A@48V(low-line)4.4A@60V(high-line)
• Heatdissipation,Watts,BTU246W,839BTU/hr
• Powerconsumption,Watts,BTU246W,839BTU/hr
Summit X480-48x with VIM2-SummitStack128 Module (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent3.4A@48V(low-line)2.7A@60V(high-line)
• Heatdissipation,Watts,BTU165W,562BTU/hr
• Powerconsumption,Watts,BTU165W,562BTU/hr
Summit X480-48tSummit X480-48t with No Installed VIM (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A
• Inputcurrent1.9A@100V(low-line)0.8A@240V(high-line)
• Heatdissipation,Watts,BTU182W,622BTU/hr
• Powerconsumption,Watts,BTU182W,622BTU/hr
Summit X480-48t with VIM2-SummitStack Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A
• Inputcurrent1.89A@100V(low-line)0.84A@240V(high-line)
• Heatdissipation,Watts,BTU187W,639BTU/hr
• Powerconsumption,Watts,BTU187W,639BTU/hr
16
Extreme Networks Data Sheet: Summit X480 Series
Technical Specifications
Summit X480-48t with VIM2-10G4X Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A
• Inputcurrent2.34A@100V(low-line)1.0A@240V(high-line)
• Heatdissipation,Watts,BTU232W,793BTU/hr
• Powerconsumption,Watts,BTU232W,793BTU/hr
Summit X480-48t with VIM2-SummitStack128 Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A
• Inputcurrent1.89A@100V(low-line)0.84A@240V(high-line)
• Heatdissipation,Watts,BTU256W,871BTU/hr
• Powerconsumption,Watts,BTU256W,871BTU/hr
Summit X480-48t with No Installed VIM (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.1A@48V(low-line)2.4A@60V(high-line)
• Heatdissipation,Watts,BTU148W,503BTU/hr
• Powerconsumption,Watts,BTU148W,503BTU/hr
Summit X480-48t with VIM2-SummitStack Module (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.24A@48V(low-line)2.5A@60V(high-line)
• Heatdissipation,Watts,BTU153W,520BTU/hr
• Powerconsumption,Watts,BTU153W,520BTU/hr
Summit X480-48t with VIM2-10G4X Module (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.1A@48V(low-line)2.4A@60V(high-line)
• Heatdissipation,Watts,BTU148W,503BTU/hr
• Powerconsumption,Watts,BTU148W,503BTU/hr
Summit X480-48t with VIM2-SummitStack128 Module (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.2A@48V(low-line)2.5A@60V(high-line)
• Heatdissipation,Watts,BTU153W,522BTU/hr
• Powerconsumption,Watts,BTU153W,522BTU/hr
Power Supply Units
Summit X480 AC PSUFor use with the Summit X480-24x, Summit X480-48x, and Summit X480-48t switches
Physical Specifications• Height:1.57inches(4.0cm)• Width:4.8inches(12.3cm)• Depth:13.31Inches(33.8cm)• Weight3.64lb(1.65kg)
Power Specifications• Voltageinputrange90to264V• Nominalinputratings100to240V,50to60Hz,8A
• Nominalinputcurrentatfullloads12A@90V(low-line)5A@230V(high-line)
• Linefrequencyrange47to63Hz• Maximuminrushcurrent15A• Output12V,37Amax,450Watts3.3V,3Amax,9.9Watts
• MaximumcontinuousDCoutputshallnotexceed450Watts
• PowersupplyinputsocketIEC320C14• PowercordinputplugIEC320C13• Powersupplycordgauge18AWG(0.75mm2)upto6feetor2metersor16AWG(1.0mm2)over6feet
• Efficiency84%typicalatfullload,highline
Summit X480 DC PSUFor use with the Summit X480-24x, X480-48x, and X480-48t switches
Physical Specifications• Height:1.57inches(4.0cm)• Width:4.8inches(12.3cm)• Depth:13.31Inches(33.8cm)• Weight2.58lb(1.17kg)
Power Specifications• NominalInput-48to-60VDC,24A• DCVoltageInputRange-40to-75V• MaximumInputAmperages13.5A@40V11.2A@48V7.5A@72V
• InrushCurrent10Apeak• InrushEnergy1.5A2S• Minimumwiresize14AWG(1.5mm2)copperstranded
• DCOutput12V,36.7A/3.3V,3.0A• DCOutputPower(W)450W
All Summit X480 Series Switches
Regulatory/SafetyNorth American Safety of ITE • UL60950-11stEd.,ListedDevice(U.S.)• CSA22.2#60950-1-031stEd.(Canada)• ComplieswithFCC21CFR1040.10(U.S.LaserSafety)
• CDRHLetterofApproval(U.S.FDAApproval)
European Safety of ITE • EN60950-1:2006• EN60825-1+A2:2001(LasersSafety)• TUV-RGSMarkbyGermanNotifiedBody• 2006/95/ECLowVoltageDirective
International Safety of ITE • CBReport&CertificateperIEC60950-1:2006+NationalDifferences
• AS/NZS60950-1(Australia/NewZealand)
EMI/EMC StandardsNorth America EMC for ITE • FCCCFR47part15ClassA(U.S.)• ICES-003ClassA(Canada)
European EMC Standards • EN55022:2006ClassA• EN55024:A2-2003ClassAincludesIEC61000-4-2,3,4,5,6,11
• EN61000-3-2,8-2006(Harmonics)• EN61000-3-31995+A2:2005(Flicker)• ETSIEN300386v1.3.3,2005-04(EMCTelecommunications)
• 2004/108/ECEMCDirective
International EMC Certifications • CISPR22:2006Ed5.2,ClassA(InternationalEmissions)
• CISPR24:A2:2002ClassA(InternationalImmunity)
• EC/EN61000-4-2:2008ElectrostaticDischarge,8kVContact,15kVAir,CriteriaA
• EC/EN61000-4-3:2008RadiatedImmunity10V/m,CriteriaA
• EC/EN61000-4-4:2005TransientBurst,1kV,CriteriaA
• IEC/EN61000-4-5:2005Surge,2kVL-L,2kVL-G,Level3,CriteriaA
• IEC/EN61000-4-6:2007ConductedImmunity,0.15-80MHz,10V/munmod.RMS,CriteriaA
• EC/EN61000-4-11:2004PowerDips&Interruptions,>30%,25periods,CriteriaC
Country Specific• VCCIClassA(JapanEmissions)• ACMA(C-Tick)(AustraliaEmissions)• CCCMark• KCCMarkEMCApproval(Korea)
Telecom Standards • EN/ETSI300386:2005-04(EMCTelecommunications)
• EN/ETSI300019(EnvironmentalforTelecommunications)
• NEBSLevel3complianttoportionsofGR-1089Issue4&GR-63Issue3asdefinedinSR3580withexceptiontofilterrequirement
• MEF9• MEF14
IEEE 802.3 Media Access Standards • IEEE802.3ab1000BASE-T• IEEE802.3z1000BASE-X• IEEE802.3ae10GBASE-X
17
Extreme Networks Data Sheet: Summit X480 Series
Technical Specifications
Environmental Standards • EN/ETSI300019-2-1v2.1.2(2000-09)–Class1.2Storage
• EN/ETSI300019-2-2v2.1.2(1999-09)–Class2.3Transportation
• EN/ETSI300019-2-3v2.1.2(2003-04)–Class3.1eOperational
• EN/ETSI300753(1997-10)–AcousticNoise• ASTMD3580RandomVibrationUnpackaged1.5G
Warranty • Ltd.1-yearonHardware• 90-daysonSoftware• Forwarrantydetails,visitwww.extremenetworks.com/go/warranty
18
Extreme Networks Data Sheet: Summit X480 Series
Ordering Information
Part Number Name Description
16301 SummitX480-48t 4810/100/1000BASE-T,4100/1000BASE-XunpopulatedSFP(shared),NoPSUwithtwounpopulatedPSUslots,oneVIM2slot,ExtremeXOSAdvancedEdgelicense
16303 SummitX480-24x 24100/1000BASE-XunpopulatedSFP,1210/100/1000BASE-T(shared),2unpopulatedXFPports,NoPSUwithtwounpopulatedPSUslots,oneVIM2slot,ExtremeXOSAdvancedEdgelicense
16304 SummitX480-48x 48100/1000BASE-XunpopulatedSFP,NoPSUwithtwounpopulatedPSUslots,oneVIM2slot,ExtremeXOSAdvancedEdgelicense
16311 VIM2-SummitStack VIM2-SummitStack,2SummitStackstackingports
16312 VIM2-10G4X VIM2-10G4X,410GBASE-XXFPports
16313 VIM2-SummitStack128 VIM2-SummitStack128,2x64Gstackingports
16315 VIM2-SummitStack-V80 VIM2-SummitStack-V80,2x40Gstackingports
16321 SummitX480CoreLicense ExtremeXOSCoreLicenseforSummitX480seriesswitches
16322 SummitX480MPLSFeaturePack
ExtremeXOSMPLSFeaturePackforSummitX480seriesswitches
11011 DirectAttachFeaturePack DirectAttachFeaturePackforSummitX450a/X460/X480,SummitX650andBlackDiamond8800SerieswithExtremXOS12.5.1orGreater
10916 SummitX480/X650FANModule
FANmoduleforSummitX480andSummitX650seriesswitches,spare
10917 SummitX480ACPSU ACPowerSupplymoduleforSummitX480seriesswitches
10918 SummitX480DCPSU DCPowerSupplymoduleforSummitX480seriesswitches
10121 10GBASE-SRXFP 10GBASE-SRXFPTransceiver,850nm,upto300monMultimodeFiber,LCConnector
10122 10GBASE-LRXFP 10GBASE-LRXFPTransceiver,1310nm,upto10kmonSingle-modeFiber,LCConnector
10124 10GBASE-ERXFP 10GBASE-ERXFPTransceiver,1550nmupto40kmonSingle-modeFiber,LCConnector
10125 10GBASE-ZRXFP 10GBASE-ZRXFPTransceiver,1550nm,upto80kmonSingle-modeFiber,LCConnector
10200 TunableDWDMXFP 10GigabitEthernetXFPTunableDWDMmodule,C-band,SMF80km,LCconnector
10051 1000BASE-SXSFP 1000BASE-SXSFP,LCConnector
10052 1000BASE-LXSFP 1000BASE-LXSFP,LCConnector
10053 1000BASE-ZXSFP 1000BASE-ZXSFP,ExtraLongDistanceSMF70km/21dBBudget,LCConnector
10056 1000BASE-BX-DSFP 1000BASE-BX-DSFP,SMF(1490nmTX/1310nmRXWavelength)
10057 1000BASE-BX-USFP 1000BASE-BX-USFP,SMF(1310nmTX/1490nmRXWavelength)
10060 100FX/1000LXSFP1 100FX/1000LXSFP,SMF,LCConnector(RequiresMCPand6dBAttenuatorfor100FX-MMFOperation)
10063 100FXSFP1 100FXSFP,MMF,LCConnector
10064 1000BASE-LX100SFP 1000BASE-LX100SFP,ExtraLongDistanceSMF100km/30dBBudget,LCConnector
10065 10/100/1000BASE-TSFP1 10/100/1000BASE-T,SFP,CAT5cable100m,RJ-45Connector
10067 100BASE-FXSFP 100MSFP,100FXMMF,(1310nm,2kmmultimodetransmission)LCconnector
10066 100BASE-LX10SFP 100MSFP,100LX10SMF,(1310nm10kmsinglemodetransmission)LCconnector
10058 100BASE-BX-DSFP 100MSFP,100BASE-BX-D,SMF(1550nmTX/1310nmRXwavelength),100Mbpsbidirectional
10059 100BASE-BX-USFP 100MSFP,100BASE-BX-U,SMF(1310nmTX/1550nmRXwavelength),100Mbpsbidirectional
1NotsupportedonComboports
Extreme Networks Data Sheet: Summit X480 Series
Make Your Network Mobile
© 2011 Extreme Networks, Inc. All rights reserved. Extreme Networks, the Extreme Networks logo, BlackDiamond, Direct Attach, Extreme Standby Router Protocol, ExtremeXOS, Ex-tremeXOS ScreenPlay, Ridgeline, Summit, SummitStack, UniStack and XNV are either registered trademarks or trademarks of Extreme Networks, Inc. in the United States and/or other countries. sFlow is the property of InMon Corporation. Specifications are subject to change without notice. 1625_09 05/11
extremenetworks.com
Corporateand North AmericaExtreme Networks, Inc.3585 Monroe Street Santa Clara, CA 95051 USAPhone +1 408 579 2800
Europe, Middle East, Africaand South AmericaPhone +31 30 800 5100
Asia PacificPhone +65 6836 5437
JapanPhone +81 3 5842 4011
Ordering Information
Part Number Name Description
10312 QSFP+passivecoppercable,1.0M
QSFP+passivecoppercable,1.0M
10315 QSFP+activefibercable,10M
QSFP+activefibercable,10M
10318 QSFP+activefibercable,100M
QSFP+activefibercable,100M
16106 StackingCable,0.5M SummitStack/UniStack™StackingCable,0.5M
16107 StackingCable,1.5M SummitStack/UniStackStackingCable,1.5M
16108 StackingCable,3.0M SummitStack/UniStackStackingCable,3.0M
16105 StackingCable,5.0M2 SummitStackStackingCable,5.0M
17030 StackingCable64G,1.0M SummitStack128StackingCable,1.0M
17026 StackingCable128Gto64G,1.0M
ConversioncableforSummitStack256andSummitStack128,1.0M
17034 StackingCable128Gto20G,1.0M
ConversioncableforSummitStack256andSummitStack,1.0M
17038 StackingCable64Gto20G,1.0M
ConversioncableforSummitStack128andSummitStack,1.0M
2NotsupportedwhenusingwithSummitX650andUniStack