Extreme Networks Data Sheet

Summit X480 Series

Make Your Network Mobile

High-Performance Switching and Routing• 48-portGigabitEthernetor24-portgigabitand2-port10GigabitEthernetconnectivityina1RUformfactor

• Optional4-port10GigabitEthernet(GbE)toprovide40Gbpsuplinks

• Optional40Gbpsstackingforuptoeightswitchesinastacktoprovideupto384GigabitEthernetconnectionsinonelogicallyintegratedunit

• Optional128Gbpsstackingforuptoeightswitchesinastacktoprovidehigh-speedstacking

• Optionalstackingvia10GbEports(SummitStack-V),oroptionalSummitStack-V8080Gbpsstacking

• SupportsLayer2andLayer3switching,aswellasMPLS/H-VPLS

High Scalability in a 1RU Compact Switch • Upto512KMACaddresssupportforscalableLayer2networks

• Upto512KIPv4routesforscalableLayer3networks

• Upto60KAccessControlLists(ACLs)forsecurenetworks

High Availability• ExtremeXOS®modularOSforhighlyavailablenetworkoperation

• Carrier-graderedundantnetworkingprotocolincludingEthernetAutomaticProtectionSwitching(EAPS)

• InternalredundantAC/DCpowersupplyandfieldreplaceable/hotswappablefantray

Summit® X480 Series—the scalable and versatile gigabit and 10 Gigabit Ethernet switch.

TheSummitX480seriesswitchisaversatile,high-endEthernetswitchfordatacenter,enterpriseaggregation,andCarrierEthernetdeployments.SummitX480helpsoptimizeapplicationperformanceforavarietyofnetworkdeploymentswithitsrichfeaturesandhighscalability.

SummitX480provideshighdensityforGigabitEthernetinasmall1RUformfactorforupto48portsinonesystemand384portsinastackedsystemusingback-wardcompatibleSummitStack™,high-speedSummitStack128runningat128gigabitspersecond,orSummitStack-V,whichutilizes10GbEportsasstackingports,enablingtheuseofstandardcablingandopticstechnologiesusedfor10GbE.SummitX480alsooffers10GigabitEthernetconnectivityforuptosixportsinonesystemand16portsinastackedsystemwiththeindustry-standardXFPinterface.

Foremergingdemandsfromvoice/dataconvergenceandstorage,SummitX480provideshighlyscalableLayer2/3switchingandMPLS/H-VPLSbysupportingupto512KLayer2MACaddressesor512KIPv4LongestPrefixMatchroutingtables.SummitX480enablesdatacenter,enterpriseandCarrierEthernetaggregationandcorebackbonedeploymentinAC-poweredandDC-poweredenvironments.

SummitX480simplifiesnetworkoperationwiththeExtremeXOSmodularOS,availableacrossawiderangeofExtremeNetworks®Ethernetswitches.TheExtremeXOSoperatingsystemprovideshighavailabilityandsimplicitywithoneOSeverywhereinthenetwork.

Target Applications• Top-of-rackswitchforserversinenterprisedatacenters

• High-performancecoreswitchforasmallnetwork

• High-performancegigabitaggregationswitchinatraditionalthree-tierednetwork

• CarrierEthernetnetworkswitchthatcanaggregateconnectivityforfirstmileaccessconcentratorssuchasDSLAMandCMTS

2

Extreme Networks Data Sheet: Summit X480 Series

High-Performance and Highly Scalable Switching and Routing Summit X480 offers core-class intelligent switching and routing with exceptional port density and high-performance stacking technology powered by the ExtremeXOS modular OS. With its high performance switching and routing, Summit X480 helps enhance the data center, Carrier Ethernet and enterprise aggregation network.

SummitStack – High-Performance StackingSummitX480supportsSummitStack,whichprovides40Gbps(VIM2-SummitStack),80Gbps(VIM2-SummitStack-V80)or128Gbps(VIM2-SummitStack128)ofstackingbandwidth.High-speed128Gbpsstackingisidealfordemandingapplica-tionswhereahighvolumeoftraffictraversesthroughthestackinglinks,yetbandwidthisnotcompromisedthroughstacking.High-speedstackingisveryusefulinapplicationssuchastopofrackwhenstackedwithSummitX480andSummitX650(requiresoptionalconversioncable)andgigabitaggregationinlargeenterpriseordatacenternetworks.Withthelongerstackingcablessuchas5-meters,stackingcanbeconfiguredthroughdifferentrackshorizontallyinarow(seeFigure3)asopposedtotypicalstackingsysteminstalledverticallyinarack.

SummitStack-V – Flexible Stacking Over 10 Gigabit Ethernet SummitStack-Vcapabilityutilizes10GbEportsasstackingports,enablingtheuseofstandardcablingandopticstech-nologiesusedfor10GbEsuchasXFP,SFP+,10GBASE-TandXENPAK.SummitStack-Vprovideslong-distancestackingconnectivityofupto40kmwhilereducingthecablecomplexityofimplementingastackingsolution.SummitStack-Venabled10GbEportsmustbephysicallydirect-connected.SummitStack-ViscompatiblewithSummitX450e,X450a,X460,X480,X650,X670andX670VswitchesrunningthesameversionofExtremeXOS.

High-Performance Switching and Routing SummitX480isavailableinthreedifferentportconfigurationoptions:24-portGigabitEthernetand2-port10GigabitEthernet(SummitX480-24x),48-portcopperGigabitEthernet(SummitX480-48t),or48-portfiberGigabitEthernet(SummitX480-48x).Allfrontpanelportsrunatnon-blocking,wire-speedperformanceandcancarrywire-ratetraffictowardstheVersatileInterfaceModule-2(VIM2)slot.SummitX480offersflexibleconfigurationbyusingoptionalVIM2moduleswhichare:4-port10GigabitEthernetModule(VIM2-10G4X),2-portSummitStackModule(VIM2-SummitStack),2-portSummitStack128Module(VIM2-SummitStack128)or2-portSummitStack-V80Module(VIM2-SummitStack-V80)(seeFigure1:PortconfigurationoptionsforSummitX480switches).

Flexible Port ConfigurationSummitX480offersflexibleportconfigurationsfromstandardconfigurationtooptionalVIM2modules.ForSummitX480-24x,halfoftheGigabitEthernetportscanhandledualpersonality—selectfromeither10/100/1000BASE-TcopperGigabitEthernetor100/1000BASE-XfiberGigabitEthernetconnectivity.InthecaseofSummitX480-48t,thelastfourGigabitEthernetportsareconfiguredasdualpersonalityportstoprovideflexibilitybetweencopperandfiberGigabitEthernet.

ThroughtheVIM2slot,SummitX480canaddanadditionalfour10GigabitEthernetorSummitStackstackingports.Forstacking,dependingupontheneedsforbandwidthacrosstheunitsinastack,SummitX480supports40GbpsSummitStack,80GbpsSummitStack-V80or128GbpsSummitStack128throughVIM2optionmodules(SeeFigure2:SummitX480-24xflexibleportconfiguration).Athirdoption,SummitStack-V,utilizes10GbEportsasstackingports.

SummitX480supportsflexible10gigabitopticaltransceiverssuchas10GBASE-SR,LR,ERandZRaswellastunableDWDM.TunableDWDM(DenseWavelengthDivisionMultiplexing)supportallowsserviceprovidersandotherstotuneXFP10GigabitEthernetopticstoaspecificfrequency,reducingtheneedforadditionalfiberrunsandXFPsparing.DigitalDiagnosticsMonitoringInterfacesupportallowsserviceprovid-erstomonitoranddiagnosepluggableopticsinreal-time.

3

Extreme Networks Data Sheet: Summit X480 Series

High-Performance and Highly Scalable Switching and Routing

VIM Options None (default option) VIM2-10G4X VIM2-SummitStack VIM2-SummitStack-V80 VIM2-SummitStack128

Summit X480-24x • 24x100/1000BASE-X(SFP)

• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)

• 2x10GBASE-X(XFP)

• 24x100/1000BASE-X(SFP)

• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)

• 6x10GBASE-X(XFP)

• 24x100/1000BASE-X(SFP)

• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)

• 2x10GBASE-X(XFP)• 2xSummitStack

• 24x100/1000BASE-X(SFP)

• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)

• 2x10GBASE-X(XFP)• 2xSummitStack-V80

• 24x100/1000BASE-X(SFP)

• 12x10/100/1000BASE-T(sharedwiththelast12SFPports)

• 2x10GBASE-X(XFP)• 2xSummitStack128

Summit X480-48t • 48x10/100/1000BASE-T• 4x100/1000BASE-X

SFP(sharedwiththelast410/100/1000BASE-Tports)

• 48x10/100/1000BASE-T• 4x100/1000BASE-X

SFP(sharedwiththelast410/100/1000BASE-Tports)

• 4x10GBASE-X(XFP)

• 48x10/100/1000BASE-T• 4x100/1000BASE-X

SFP(sharedwiththelast410/100/1000BASE-Tports)

• 2xSummitStack

• 48x10/100/1000BASE-T• 4x100/1000BASE-X

SFP(sharedwiththelast410/100/1000BASE-Tports)

• 2xSummitStack-V80

• 48x10/100/1000BASE-T• 4x100/1000BASE-X

SFP(sharedwiththelast410/100/1000BASE-Tports)

• 2xSummitStack128

Summit X480-48x • 48x100/1000BASE-XSFP

• 48x100/1000BASE-XSFP

• 4x10GBASE-X(XFP)

• 48x100/1000BASE-XSFP

• 2xSummitStack

• 48x100/1000BASE-XSFP

• 2xSummitStack-V80

• 48x100/1000BASE-XSFP

• 2xSummitStack128

Figure 1: Port Configuration Options for Summit X480 Switches

Figure 3: SummitStack Across Racks in a Row

5391-03

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Rack ServerRack ServerRack ServerRack ServerRack ServerRack ServerRack Server Rack Server

Save Power, Cost and SpaceSummit® X480 provides virtualized end-of-row switches by physically installing top-of-rack switches with a 128G stacking module.

Figure 2: Summit X480-24x Flexible Port Configuration

12x100/1000BASE-X 2-port10GBSE-XXFP12x100/1000BASE-Xor12x10/100/1000BASE-T

4

Extreme Networks Data Sheet: Summit X480 Series

High-Performance and Highly Scalable Switching and Routing

High Scalability in 1RU Compact Switch

SummitX480supportshighlyscalableLayer2orLayer3networks,aswellashighlysecurenetworks.SummitX480hasexpansionmemorycalledTCAMbuiltinsidewhichcanbepartitionedbyapplicationtypesorbydeploymentscenarios.ForlargerLayer2networkdeployments,SummitX480can

supportupto512KMACaddresses.SimilarlyforlargerLayer3routingenvironments,SummitX480cansupportcoreroutingclassscalabilityforupto512KIPv4routingLPMentriesinhardware(SeeFigure4:SummitX480scalability).

Supports Virtualized Data Centers

SummitX480switchesalsosupportDirectAttach™,whicheliminatesthevirtualswitchlayer,simplifyingthenetworkandimprovingperformance.DirectAttachenablesdatacentersimplificationbyreducingnetworktiersfrom4or5tierstojust3or2tiers,dependingonthesizeofthedatacenter.Tofurtherenhancedatacenteroperations,SummitX480switches

supportXNV™(ExtremeXOSNetworkVirtualization),asetofsoftwaremodulesfortheExtremeXOSbasedswitchingproductportfolio,andavailableviatheDataCenterFeaturePackforExtremeNetworksRidgeline™,anetworkandservicemanagementapplication.XNVbringsinsight,controlandautomationforhighlyvirtualizeddatacenterstothenetwork.

Type L2 MAC L3 Host (IPv4/v6)

L3 LPM Route (IPv4/v6)

ACL(Ingress/Egress)

Lower Power Mode 32K 16K/8K 16K/8K 8K/1K

Default (Layer 2+Layer 3) 256K 16K/8K 256K/8K 8K/1K

Large Layer 2 Network Configuration 512K 16K/8K 16K/8K 8K/1K

Large Layer 3 Network Configuration 32K 16K/8K 512K/8K 8K/1K

Security Configuration 32K 16K/8K 16K/8K 60K/1K

Figure 4: Summit X480 Scalability

5

Extreme Networks Data Sheet: Summit X480 Series

High-Performance and Highly Scalable Switching and Routing

Figure 5: Summit X480 in a Carrier Ethernet Application

5392-03

Subscriber Access WAN CoreMetroContent and

Service Providers

Mobile

Private Data

Video

Voice

Public IP

Mobile Data

Mobile Video

IPTV

VOD

E-LAN

E-Line

Residential

Fixed• DSL• TDM• CMTS• PON• FTTX

Wireless• Mobile• LTE• WiMAX

Business

Mobile

Roaming

Metro Ethernet TransportIP Services IP ServicesMPLS

Core Router

Core Router

Metro Core

BlackDiamond®

8810 with 8900-xlSeries Modules

MetroAggregation

Summit X480

MetroAggregation

Summit X480

MetroAggregation

Summit® X480

1 GbE 10 GbE

96-port 10/100/1000BASE-T, MPU21

96-port 10/100/1000BASE-T, MPU21

Intelligent Switching and MPLS/ H-VPLS Support

SummitX480supportssophisticatedandintelligentLayer2switching,aswellasLayer3IPv4/IPv6routingincludingpolicy-basedswitching/routing,ProviderBridges,bidirectionalingressandegressAccessControlLists,andbandwidthcontrolby8Kbpsgranularitybothforingressandegress.ToprovidescalablenetworkarchitecturesusedmainlyforCarrierEthernetnetworkdeployment,throughafeaturepackSummitX480

supportsMPLSLSPbasedLayer3forwardingandHierarchicalVPLS(H-VPLS)fortransparentLANservices.WithH-VPLS,transparentLayer3networkscanbeextendedthroughouttheLayer3networkcloudbyusingaVPLStunnelbetweentheregionaltransparentLANservicestypicallybuiltbyProviderBridges(IEEE802.1ad)technology(seeFigure5:SummitX480inaCarrierEthernetapplication).

6

Extreme Networks Data Sheet: Summit X480 Series

High Availability Powered by the ExtremeXOS OS, Summit X480 supports process recovery and application upgrades without the need for a system reboot. Summit X480 provides the high network availability required for mission-critical servers and applications through its advanced modular OS, highly available hardware architecture and carrier-grade network redundancy protocols.

Software-Enhanced AvailabilitySoftware-enhancedavailabilityallowsuserstoremaincon-nectedtothenetworkevenifpartofthenetworkinfrastructureisdown.SummitX480continuouslychecksforproblemsintheuplinkconnectionsusingadvancedLayer3protocolssuchasOSPF,VRRPandExtremeStandbyRouterProtocol™(ESRP,supportedinLayer2orLayer3),anddynamicallyroutestrafficaroundtheproblem.

Equal Cost MultipathEqualCostMultipath(ECMP)routingallowsuplinkstobeloadbalancedforperformanceandcostsavingswhilealsosupport-ingredundantfailover.Ifanuplinkfails,trafficisautomaticallyroutedtotheremaininguplinksandconnectivityismaintained.

Link Aggregation (802.3ad)Linkaggregation(LAG)allowstrunkingofuptoeightlinksonasinglelogicalconnection.Amaximumof128linkaggregationgroupscanbecreated.

Multi-Switch LAG (M-LAG)M-LAGcanaddressbandwidthlimitationsandimprovenetworkresiliency,inpartbyroutingnetworktrafficaroundbottlenecks,reducingtherisksofasinglepointoffailure,andallowingloadbalancingacrossmultipleswitches.

Voice-Grade Stacking with SummitStackAllSummitStackstackingarchitectureisdesignedtosupportmission-criticalapplicationsbyitshighlyavailable,rapidfailovercapabilitywithn-1masterredundancy,distributedLayer2andLayer3switching,linkaggregationacrossthestack,anddistributeduplinks.SummitStacksupportsuptoeightunitsinastack,includinganymixofSummitX650,X480,X460,X450a,X450eandX250erunningthesameversionofExtremeXOSandprovides50millisecondsfailoverforpathfailureandhitlessmaster/backupfailoveralongwithhitlessprotocolsupportsuchasOSPFgracefulrestartandNetworkLoginuserauthentication.

Modular Operating System for Continuous Operation

Preemptive Multitasking and Protected MemorySummitX480seriesswitchesalloweachofmanyapplica-tions—suchasOpenShortestPathFirst(OSPF)andSpanningTreeProtocol(STP)—torunasseparateOSprocessesthatareprotectedfromeachother.ThisdrivesincreasedsystemintegrityandinherentlyprotectsagainstDoSattacks.

Process Monitoring and RestartExtremeXOSincreasesnetworkavailabilityusingprocessmonitoringandrestart.EachindependentOSprocessismonitoredinrealtime.Ifaprocessbecomesunresponsiveorstopsrunning,itcanbeautomaticallyrestarted.

Loadable Software ModulesThemodulardesignofExtremeXOSOSallowstheupgradingofindividualsoftwaremodules,shouldthisbenecessary,leadingtohigheravailabilityinthenetwork(SeeFigure7:ExtremeXOSmodulardesign).

High Availability Network Protocols

Ethernet Automatic Protection Switching (EAPS)EAPSallowstheIPnetworktoprovidethelevelofresiliencyanduptimethatusersexpectfromtheirtraditionalvoicenetwork.EAPSismoreadaptablethanSpanningTreeorRapidSpanningTreeProtocolsandofferssub-second(lessthan50milliseconds)recoverythatdeliversconsistentfailoverregard-lessofthenumberofVLANs,networknodesornetworktopology.SinceEAPSallowsthenetworktorecoveralmosttransparently,Voice-over-IP(VoIP)callswillnotdropanddigitalvideofeedswillnotfreezeorpixelizeinmostsituations.

Spanning Tree/Rapid Spanning Tree ProtocolsSummitX480supportsSpanningTree(802.1D),PerVLANSpanningTree(PVST+),RapidSpanningTree(802.1w)andMultipleInstancesofSpanningTree(802.1s)protocolsforLayer2resiliency.

7

Extreme Networks Data Sheet: Summit X480 Series

High Availability

SummitX480provideschassis-likemanagementandavailabilitywithitsSummitStackstackingtechnology(SeeFigure8:SummitStackstackingarchitecture).

Hardware RedundancySummitX480supportsadualredundantAC/DCpowersupplytoprovidehighavailability.Thepowersupplycanbehot-swappedandreplacedshoulditfail.SummitX480supportsahot-swappable,fieldreplaceablefan.

Alternatively,youmaychoosehigh-speed80Gbpsstacking,whichisidealfordemandingapplicationswhereahighvolumeoftraffictraversesthroughthestackinglinks,yetbandwidthisnotcompromisedthroughstacking.SummitStack-V80alsobreaksthedistancelimitationforstackingtechnologybyusingQSFP+technology.SummitStack-V80cansupportpassivecoppercable(upto5m),activemulti-modefibercable(upto100m),andQSFP+opticaltransceiverswhichwillbethestandardtechnologyfor40GbE.WithSummitStack-V80,theSummitX460providesaflexiblestackingsolutioninsidethedatacenterorcentralofficetocreateavirtualizedswitchinginfrastructureacrossrowsofracks.SummitStack-V80iscompatiblewithSummitX460,X480andX670VswitchesrunningthesameversionofExtremeXOS.

Figure 6: Summit X480 High Availability Design4-port10GXFP SummitStack-V80SummitStack128G

VIM2SlotRemovableFan

(Hot-SwappablewithSummitX480) RedundantHot-SwappableAC/DCPSU

SummitStack40G

5027-04

• Processes are monitored and can be restarted or other action taken if necessary

• Hitless failover infrastructure for dual management systems and stacking

BGP OSPF SSH-2 V1.3.1

SSH-2 V1.3.2

ThirdParty

Application

ExtremeXOSKernel

Kernel LoadableModule

Memory protected processes under

real-time scheduling that cannot impact each other nor

kernel

1Designed to allow

application modules to be

upgraded during runtime

3

Application modules can be added during

runtime

2

5389-05

• Single management point for up to eight units• High-speed 40G–128G stacking• Rapid Failover for converged applications• Can mix Summit X650, X480, X460, X450e, X450a, and X250e series switches for SummitStack™ 40 Gbps stacking

Figure 7: ExtremeXOS Modular Design Figure 8: SummitStack Stacking Architecture

8

Extreme Networks Data Sheet: Summit X480 Series

Comprehensive Security Management Implementing a secure network means providing protection at the network perimeter as well as the core. Summit X480 uses advanced security functions in protecting your network from known or potential threats.

communicatewithotherportsinthesameVLANoverLayer2orLayer3.PrivateVLANportscanonlycommunicatewithadesignated“uplink”port.Inaddition,aPrivateVLANprovidesseparationofbroadcastdomainswithinthesameVLAN.

Threat Detection and Response

CLEAR-Flow Security Rules EngineCLEAR-Flowprovidesfirstorderthreatdetectionandmitiga-tion,andmirrorstraffictoappliancesforfurtheranalysisofsuspicioustrafficinthenetwork.

Protocol Anomaly DetectionTheExtremeNetworkschipsetscontainbuilt-inhardwareprotocolcheckersthatsupportportsecurityfeaturesforsecurityapplications,suchasstatelessDoSprotection.Theprotocolcheckersallowuserstodropthepacketsbasedonconditions,whicharecheckedforingresspacketspriortotheLayer2/Layer3entrytable.

sFlowsFlow®isasamplingtechnologythatprovidestheabilitytosampleapplication-leveltrafficflowsonallinterfacessimultaneously.

IPFIXIPFIX(InternetProtocolFlowInformationeXport)definesanInternetstandards-trackprotocolforafollow-onprotocoltotheproprietaryNetflow.ThetechnologyisacomplementaryprotocoltosFlow.IPFIXgathersinformationaboutnetworkflowsthroughtheswitchandsendstheinformationtoanexternalcollector.SummitX480includeshardwaresupporttokeeptrackoftheflowrecords.

Port MirroringSummitX480supportsmany-to-oneandone-to-manyportmirroring.Thisallowsthemirroringoftraffictoanexternalnetworkappliancesuchasanintrusiondetectiondevicefortrendanalysisorforutilizationbyanetworkadministratorfordiagnosticpurposes.Portmirroringcanalsobeenabledacrossswitchesinastack.

Robust IP and MAC Security Framework

NetLoginNetworkLoginprovidesthreetypesofauthentication—Web-based,MAC-based,and802.1x—toproperlyauthenticatenetworkusersagainstRADIUSservers.WhencombinedwithExtremeNetworksUniversalPortManager(UPM),ITadminis-tratorscandynamicallyprovisionpoliciestoassociatednetworkusersbasedonrolesorUPMprofiles.

Media Access Control (MAC) SecurityMACsecurityallowsthelockdownofaporttoagivenMACaddressandlimitingthenumberofMACaddressesonaport.Thiscanbeusedtodedicateportstospecifichostsordevicesandavoidabuseoftheport.Inaddition,anagingtimercanbeconfiguredfortheMAClockdown,protectingthenetworkfromtheeffectsofattacksusing(oftenrapidly)changingMACaddresses.

IP SecurityExtremeXOSIPsecurityframeworkprotectsthenetworkinfrastructure,networkservicesandhostcomputersfromrogueaccess,spoofingandman-in-the-middleattacks.Italsoprotectsthenetworkfromstaticallyconfiguredand/orspoofedIPaddressesandbuildsanexternaltrusteddatabaseofMAC/IP/portbindingsprovidingthetraffic’ssourcefromaspecificaddressforimmediatedefense.

Identity ManagerIdentityManagerallowsnetworkmanagerstotrackuserswhoaccesstheirnetwork.UseridentityiscapturedbasedonNetLoginauthentication,LLDPdiscoveryandKerberossnooping.ExtremeXOSusestheinformationtothenreportontheMAC,VLAN,computerhostname,andportlocationoftheuser.Further,IdentityManagercancreatebothrolesandpolicies,andthenbindthemtogethertocreaterole-basedprofilesbasedonorganizationalstructureorotherlogicalgroupings,andapplythemacrossmultipleuserstoallowappropriateaccesstonetworkresources.

Private VLANsPrivateVLANsprovideport-to-portsecuritytopreventunauthorizedcommunicationofuserswithinthesameVLAN.UnlikenormalVLANs,portsenabledforPrivateVLANscannot

9

Extreme Networks Data Sheet: Summit X480 Series

Comprehensive Security Management

ExtremeNetworkshasdevelopedtoolsthatsimplifyandhelpinefficientlymanagingyournetwork.Ridgelinenetworkandservicemanagementprovidesfault,configuration,accounting,performanceandsecurityfunctions,allowingmoreeffectivemanagementofExtremeNetworksproducts,solutionsandthird-partydevices,inaconvergednetwork.

Forcarriernetworks,Ridgelineenablestheshiftfromreactivecircuitmonitoringtoproactiveservicemanagement.ThekeyfeaturesintegratedintotheServiceAdvisorFeaturePackunifyservicefulfillment,serviceassuranceandserviceengineeringtoenablecarrierstomoreeffectivelymanagenext-generationresidentialtripleplay,businessEthernetandEthernetmobilebackhaulservices.

Line-Rate ACLsACLsareoneofthemostpowerfulcomponentsusedincontrollingnetworkresourceutilizationaswellasprotectingthenetwork.ACLsareusedforfilteringthetraffic,aswellasclassifyingthetrafficflowtocontrolbandwidth,priority,mirroring,andpolicy-basedrouting/switching.

Denial of Service ProtectionSummitX480effectivelyhandlesDenialofService(DoS)attacks.IftheswitchdetectsanunusuallylargenumberofpacketsintheCPUinputqueue,itassemblesACLsthatautomaticallystopthesepacketsfromreachingtheCPU.Afteraperiodoftime,theseACLsareremoved,andreinstallediftheattackcontinues.

Secure and Comprehensive Network ManagementSummitX480supportscomprehensivenetworkmanagementthroughCommandLineInterface(CLI),SNMPv1,v2c,v3,andExtremeXOSScreenPlay™embeddedXML-basedWebuserinterface.Withavarietyofmanagementoptionsandconsis-tencyacrossotherExtremeNetworksmodularandstackableswitches,SummitX480seriesswitchesprovideeaseofmanagementfordemandingconvergedapplications.

10

Extreme Networks Data Sheet: Summit X480 Series

Target Applications

Top-of-Rack Switch for Servers in the Enterprise Data Centers Intheenterprisedatacenter,manyserversandstoragesystemsarepackedinracks,withallsystemsneedinghigh-speedconnectivity.Atop-of-rackarchitectureisonewaytosimplifythecablinginfrastructureandminimizethespacerequirementsintheenterprisedatacenter.SummitX480isoptimizedtosupporthigh-densityGigabitEthernetconnectivityforserversandothernetwork-attacheddevicesandprovideshigh-speed80Gbpsor128GbpsstackingconnectivitywiththeSummitX65010GigabitEthernetswitchtoprovidethehybriddeploymentforbothgigabitand10gigabitenabledserversinthedatacenters.

High-Performance 10 Gigabit Core Switch for a Small Network and Aggregation Switch in a Traditional Three-Tiered Network SummitX480offersenterprisecore-classscalabilityforbothLayer2andLayer3switching.SummitX480cansupportupto512,000Layer2MACaddressesor512,000IPv4longestprefixmatchingroutes.TheSummitX480switchcanalsobeusedinthenetworkaggregationlayerinanenterprisenetwork.Withitsversatiledesign,SummitX480canhelpsimplifyenterprisenetworkdeployment.

5390-03

BlackDiamond®

8810BlackDiamond

8810

Core Layer

Access LayerTop of the Rack

Summit® X480 Summit X650 Summit X480 Summit X650 Summit X480 Summit X650

CampusNetwork

ServerRack

ServerRack

ServerRack

ServerRack

ServerRack

ServerRack

Figure 9: Top-of-Rack Architecture with Hybrid Deployment

5393-03

Summit X480

Summit X480

Summit X480

Summit X480

Summit X460Summit® X460

5394-03

Summit X450e

Summit X480Summit® X480

Summit X460Summit X450eSummit X460

Network Core

Figure 10: High-Performance 10G Core Switch

Figure 11: Summit X480 as an Aggregation Switch in a Three-Tier Network

11

Extreme Networks Data Sheet: Summit X480 Series

Target Applications

Carrier Ethernet Network Switch that can Aggregate Connectivity for First Mile Access Concentrators SummitX480isanidealservicedeliveryplatformforCarrierEthernetnetworks.Theadvancedtrafficmanagement,resiliencyandscalabilityfeaturesgiveittheflexibilitytobedeployedattheProviderEdgeorasanaggregationswitch.BysupportinghighlyscalableLayer2andLayer3featuresalongwithMPLS/H-VPLSinhardware,SummitX480canhelpsimplifythenetworkdeployment.

5392-03

Subscriber Access WAN CoreMetroContent and

Service Providers

Mobile

Private Data

Video

Voice

Public IP

Mobile Data

Mobile Video

IPTV

VOD

E-LAN

E-Line

Residential

Fixed• DSL• TDM• CMTS• PON• FTTX

Wireless• Mobile• LTE• WiMAX

Business

Mobile

Roaming

Metro Ethernet TransportIP Services IP ServicesMPLS

Core Router

Core Router

Metro Core

BlackDiamond®

8810 with 8900-xlSeries Modules

MetroAggregation

Summit X480

MetroAggregation

Summit X480

MetroAggregation

Summit® X480

1 GbE 10 GbE

96-port 10/100/1000BASE-T, MPU21

96-port 10/100/1000BASE-T, MPU21

Figure 12: Summit X480 in a Carrier Ethernet Application

12

Extreme Networks Data Sheet: Summit X480 Series

Technical Specifications

ExtremeXOS 12.5 Supported Protocols

Switching • Switching(EAPS)andEAPSv2• IEEE802.1D–1998SpanningTreeProtocol(STP)

• IEEE802.1D–2004SpanningTreeProtocol(STPandRSTP)

• IEEE802.1w–2001RapidReconfigurationforSTP,RSTP

• IEEE802.1Q–2003(formerlyIEEE802.1s)MultipleInstancesofSTP,MSTP

• EMISTP,ExtremeMultipleInstancesofSpanningTreeProtocol

• PVST+,PerVLANSTP(802.1Qinteroperable)• Draft-ietf-bridge-rstpmib-03.txt–DefinitionsofManagedObjectsforBridgeswithRapidSpanningTreeProtocol

• ExtremeStandbyRouterProtocol(ESRP)• IEEE802.1Q–1998VirtualBridgedLocalAreaNetworks

• IEEE802.3adStaticloadsharingconfigura-tionandLACPbaseddynamicconfiguration

• SoftwareRedundantPorts• Multi-switchLinkAggregationGroups(M-LAG)

• IEEE802.1AB–LLDPLinkLayerDiscoveryProtocol

• LLDPMediaEndpointDiscovery(LLDP-MED),ANSI/TIA-1057,draft08

• ExtremeDiscoveryProtocol(EDP)• ExtremeLoopRecoveryProtocol(ELRP)• ExtremeLinkStateMonitoring(ELSM)• IEEE802.1agL2Pingandtraceroute,ConnectivityFaultManagement

• ITU-TY.1731Framedelaymeasurements

Management and Traffic Analysis • RFC2030SNTP,SimpleNetworkTimeProtocolv4

• RFC854Telnetclientandserver• RFC783TFTPProtocol(revision2)• RFC951,1542BootP• RFC2131BOOTP/DHCPrelayagentandDHCPserver

• RFC1591DNS(clientoperation)• RFC1155StructureofManagementInformation(SMIv1)

• RFC1157SNMPv1• RFC1212,RFC1213,RFC1215MIB-II,Ethernet-LikeMIB&TRAPs

• RFC1573EvolutionofInterface• RFC1650Ethernet-LikeMIB(updateofRFC1213forSNMPv2)

• RFC1901,1905–1908SNMPv2c,SMIv2andRevisedMIB-II

• RFC2576CoexistencebetweenSNMPVersion1,Version2andVersion3

• RFC2578–2580SMIv2(updatetoRFC1902–1903)

• RFC3410–3415SNMPv3,userbasedsecurity,encryptionandauthentication

• RFC3826–TheAdvancedEncryptionStandard(AES)CipherAlgorithmintheSNMPUser-basedSecurityModel

• RFC1757RMON4groups:Stats,History,AlarmsandEvents

• RFC2021RMON2(probeconfiguration)• RFC2613SMONMIB• RFC2925Ping/TracerouteMIB• RFC2668802.3MAUMIB• draft-ietf-hubmib-mau-mib-v3-02.txt• RFC1643EthernetMIB• RFC1493BridgeMIB• RFC2096IPv4ForwardingTableMIB• RFC2737EntityMIBv2• RFC2233InterfaceMIB• RFC3621PoE-MIB(PoEswitchesonly)• IEEE802.1agMIB• SecureShell(SSH-2)clientandserver• SecureCopy(SCP-2)clientandserver• SecureFTP(SFTP)server• sFlowversion5• RFC3917IPFIX• Configurationlogging• MultipleImages,MultipleConfigs• RFC3164BSDSyslogProtocolwithMultipleSyslogServers– 999LocalMessages(criticalsstoredacrossreboots)

• ExtremeNetworksvendorMIBs(includesFDB,PoE,CPU,MemoryMIBs)

• XMLAPIsoverTelnet/SSHandHTTP/HTTPS• Web-baseddevicemanagementinterface–ExtremeXOSScreenPlay™

• IPRouteCompression• SFF-8472DDMI(DigitalDiagnosticsMonitoringInterface)

• Stacking–SummitStack,SummitStack-VandSummitStack128

Security, Switch and Network Protection • SecureShell(SSH-2),SecureCopy(SCP-2)andSFTPclient/serverwithencryption/authentication(requiresexportcontrolledencryptionmodule)

• SNMPv3userbasedsecurity,withencryption/authentication(seeabove)

• RFC1492TACACS+• RFC2138RADIUSAuthentication• RFC2139RADIUSAccounting• RFC3579RADIUSEAPsupportfor802.1x• RADIUSPer-commandAuthentication• AccessProfilesonAllRoutingProtocols• AccessPoliciesforTelnet/SSH-2/SCP-2• NetworkLogin–802.1x,WebandMAC-basedmechanisms

• IEEE802.1x–2001Port-BasedNetworkAccessControlforNetworkLogin

• MultiplesupplicantswithmultipleVLANsforNetworkLogin(allmodes)

• Fallbacktolocalauthenticationdatabase(MACandWeb-basedmethods)

• GuestVLANfor802.1x• RFC1866HTML–UsedforWeb-basedNet-workLoginandExtremeXOSScreenPlay

• SSL/TLStransport–usedforWeb-basedNetworkLoginandExtremeXOSScreen-Play(requiresexportcontrolledencryptionmodule)

• MACSecurity–LockdownandLimit• IPSecurity–RFC3046DHCPOption82withportandVLANID

• IPSecurity–TrustedDHCPServer• Layer2/3/4AccessControlLists(ACLs)• RFC2267NetworkIngressFiltering

• RPF(UnicastReversePathForwarding)ControlviaACLs

• Wire-speedACLs• RateLimiting/ShapingbyACLs• IPBroadcastForwardingControl• ICMPandIP-OptionResponseControl• SYNattackprotection• CPUDoSProtectionwithtrafficrate-limitingtomanagementCPU

• Robustagainstcommonnetworkattacks:– CERT(http://www.cert.org)– CA-2003-04:“SQLSlammer”– CA-2002-36:“SSHredder”– CA-2002-03:SNMPvulnerabilities– CA-98-13:tcp-denial-of-service– CA-98.01:smurf– CA-97.28:Teardrop_Land-Teardropand“LAND“attack– CA-96.26:ping– CA-96.21:tcp_syn_flooding– CA-96.01:UDP_service_denial– CA-95.01:IP_Spoofing_Attacks_and_Hijacked_Terminal_Connections– IPOptionsAttack

• HostAttackProtection– Teardrop,boink,opentear,jolt2,newtear,nestea,syndrop,smurf,fraggle,papasmurf,synk4,raped,winfreeze,ping–f,pingofdeath,pepsi5,Latierra,Winnuke,Simping,Sping,Ascend,Stream,Land,Octopus

Security, Router Protection• IPSecurity–DHCPenforcementviaDisableARPLearning

• IPSecurity–GratuitousARPProtection• IPSecurity–DHCPSecuredARP/ARPValidation

• RoutingprotocolMD5authentication

Security Detection and Protection• CLEAR-Flow,threshold-basedalertsandactions(in non-SummitStack configuration only)

• IdentityManager

IPv4 Host Services• RFC1122HostRequirements• RFC768UDP• RFC791IP• RFC792ICMP• RFC793TCP• RFC826ARP• RFC894IPoverEthernet• RFC1027ProxyARP• RFC2068HTTPserver• IGMPv1/v2/v3SnoopingwithConfigurableRouterRegistrationForwarding

• IGMPFilters• PIMSnooping• StaticIGMPMembership• MulticastVLANRegistration(MVR)

IPv4 Router Services• RFC1812RequirementsforIPVersion4Routers

• RFC1519CIDR• RFC1256IPv4ICMPRouterDiscovery(IRDP)• StaticUnicastRoutes• StaticMulticastRoutes

13

Extreme Networks Data Sheet: Summit X480 Series

• RFC1058RIPv1• RFC2453RIPv2• StaticECMP• RFC1112IGMPv1• RFC2236IGMPv2• RFC3376IGMPv3• RFC2933IGMPMIB• RFC2096IPv4ForwardingTableMIB• RFC1724RIPv2MIB• RFC3768VRRPv2• RFC2787VRRPMIB• RFC2328OSPFv2(Edge-mode)• OSPFECMP• OSPFMD5Authentication• RFC1587OSPFNSSAOption• RFC1765OSPFDatabaseOverflow• RFC2370OSPFOpaqueLSAOption• RFC3623OSPFGracefulRestart• RFC1850OSPFv2MIB• RFC2362PIM-SM(Edge-mode)• RFC2934PIMMIB• RFC3569,draft-ietf-ssm-arch-06.txtPIM-SSMPIMSourceSpecificMulticast

• draft-ietf-pim-mib-v2-o1.txt• Mtrace,a“traceroute”facilityforIPMulticast:draft-ietf-idmr-traceroute-ipm-07

• Mrinfo,themulticastrouterinformationtoolbasedonAppendix-Bofdraft-ietf-idmr-dvmrp-v3-11

IPv6 Host Services• RFC3587,GlobalUnicastAddressFormat• PingoverIPv6transport• TracerouteoverIPv6transport• RFC5095,InternetProtocol,Version6(IPv6)Specification

• RFC4861,NeighborDiscoveryforIPVersion6,(IPv6)

• RFC2463,InternetControlMessageProtocol(ICMPv6)fortheIPv6Specification

• RFC2464,TransmissionofIPv6PacketsoverEthernetNetworks

• RFC2465,IPv6MIB,GeneralGroupandTextualConventions

• RFC2466,MIBforICMPv6• RFC2462,IPv6StatelessAddressAutoConfiguration–HostRequirements

• RFC1981,PathMTUDiscoveryforIPv6,August1996–HostRequirements

• RFC3513,InternetProtocolVersion6(IPv6)AddressingArchitecture

• TelnetserveroverIPv6transport• SSH-2serveroverIPv6transport

IPv6 Interworking and Migration• RFC2893,ConfiguredTunnels• RFC3056,6to4

IPv6 Router Services • RFC2462,IPv6StatelessAddressAutoConfiguration–RouterRequirements

• RFC1981,PathMTUDiscoveryforIPv6,August1996–RouterRequirements

• RFC2710,IPv6MulticastListenerDiscoveryv1(MLDv1)Protocol

• StaticUnicastroutesforIPv6• RFC2080,RIPng• RFC2740OSPFv3(edgemode)• StaticECMP

Core Protocols for Layer 2, IPv4 and IPv6 Requires Core License

• EAPSv2SharedPorts–multipleinterconnectionsbetweenrings

• PIM-DMDraftIETFPIMDenseModedraft-ietf-idmr-pim-dm-05.txt,draft-ietf-pim-dm-new-v2-04.txt

• RFC3618MulticastSourceDiscoveryProtocol(MSDP)

• RFC3446AnycastRPusingPIMandMSDP• RFC2740OSPFv3,OSPFforIPv6• RFC1771BorderGatewayProtocol4• RFC1965AutonomousSystemConfedera-tionsforBGP

• RFC2796BGPRouteReflection(supersedesRFC1966)

• RFC1997BGPCommunitiesAttribute• RFC1745BGP4/IDRPforIP-OSPFInteraction• RFC2385TCPMD5AuthenticationforBGPv4• RFC2439BGPRouteFlapDamping• RFC2918RouteRefreshCapabilityforBGP-4• RFC3392CapabilitiesAdvertisementwithBGP-4

• RFC4360BGPExtendedCommunitiesAttribute

• RFC4486SubcodesforBGPCeaseNotificationmessage

• draft-ietf-idr-restart-10.txtGracefulRestartMechanismforBGP

• RFC4760MultiprotocolextensionsforBGP-4• RFC1657BGP-4MIB• RFC4893BGPSupportforFour-OctetASNumberSpace

• Draft-ietf-idr-bgp4-mibv2-02.txt–EnhancedBGP-4MIB

• RFC1195UseofOSIIS-ISforRoutinginTCP/IPandDualEnvironments(TCP/IPtransportonly)

• RFC2763DynamicHostnameExchangeMechanismforIS-IS

• RFC2966Domain-widePrefixDistributionwithTwo-LevelIS-IS

• RFC2973IS-ISMeshGroups• RFC3373Three-wayHandshakeforIS-ISPoint-to-PointAdjacencies

• Draft-ietf-isis-restart-02RestartSignalingforIS-IS

• Draft-ietf-isis-ipv6-06RoutingIPv6withIS-IS• Draft-ietf-isis-wg-multi-topology-11MultiTopology(MT)RoutinginIS-IS

QoS and VLAN ServicesQuality of Service and Policies• IEEE802.1D–1998(802.1p)PacketPriority• RFC2474DiffServPrecedence,including8queues/port

• RFC2598DiffServExpeditedForwarding(EF)• RFC2597DiffServAssuredForwarding(AF)• RFC2475DiffServCoreandEdgeRouterFunctions

Traffic Engineering • RFC3784IS-ISExternsforTrafficEngineer-ing(widemetricsonly)

VLAN Services: VLANs, vMANs • IEEE802.1QVLANTagging• IEEE802.1v:VLANclassificationbyProtocolandPort

• Port-basedVLANs• Protocol-basedVLANs

• MAC-basedVLANs• MultipleSTPdomainsperVLAN• UpstreamForwardingOnly/DisableFlooding• RFC5517PrivateVLANs• VLANTranslation• IEEE802.1adProviderBridgeNetwork,virtualMANs(vMANs)

• vMANEthertypeTranslation/SecondaryvMANEthertype

• MulticastSupportforPVLAN• MulticastSupportforVLANAggregation• VLANAggregation

MPLS and VPN ServicesMulti-Protocol Label Switching (MPLS)Requires MPLS Feature Pack License

• RFC2961RSVPRefreshOverheadReductionExtensions

• RFC3031MultiprotocolLabelSwitchingArchitecture

• RFC3032MPLSLabelStackEncoding• RFC3036LabelDistributionProtocol(LDP)• RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnels

• RFC3630TrafficEngineeringExtensionstoOSPFv2

• RFC3811DefinitionsofTextualConventions(TCs)forMultiprotocolLabelSwitching(MPLS)Management

• RFC3812MultiprotocolLabelSwitching(MPLS)TrafficEngineering(TE)Manage-mentInformationBase(MIB)

• RFC3813MultiprotocolLabelSwitching(MPLS)LabelSwitchingRouter(LSR)ManagementInformationBase(MIB)

• RFC3815DefinitionsofManagedObjectsfortheMultiprotocolLabelSwitching(MPLS),LabelDistributionProtocol(LDP)

• RFC4090FastRe-routeExtensionstoRSVP-TEforLSP(DetourPaths)

• RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailures(LSPPing)

• draft-ietf-bfd-base-09.txtBidirectionalForwardingDetection

Layer 2 VPNsRequires MPLS Feature Pack License

• RFC4447PseudowireSetupandMaintenanceusingtheLabelDistributionProtocol(LDP)

• RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworks

• RFC4762VirtualPrivateLANServices(VPLS)usingLabelDistributionProtocol(LDP)Signaling

• RFC5085PseudowireVirtualCircuitConnectivityVerification(VCCV)

• RFC5542DefinitionsofTextualConventionsforPseudowire(PW)Management

• RFC5601Pseudowire(PW)ManagementInformationBase(MIB)

• RFC5602Pseudowire(PW)overMPLSPSNMIB

• RFC5603EthernetPseudowire(PW)MIB• draft-ietf-l2vpn-vpls-mib-02.txtVirtualPrivateLANServices(VPLS)MIB

Data Center• DirectAttach(IEEE802VEPA)(Supportedinafeaturepack)

• XNV(ExtremeXOSNetworkVirtualization)

Technical Specifications

14

Extreme Networks Data Sheet: Summit X480 Series

Summit X480

General Specifications Performance• 176Gbpsswitchfabricbandwidth• 224Gbps,448Gbps(withVIM2-10G4X)aggregatedswitchbandwidth

• 71.4Mpps,101.2Mpps(withVIM2-Summit-Stack),166.7Mpps(withVIM2-Summit-Stack128),130.9Mpps(withVIM2-10G4X)frameforwardingrate

• Lessthan4microsecondlatency(64-byte)• 9216Bytemaximumpacketsize(JumboFrame)

• 128loadsharingtrunks,upto8memberspertrunk

• 4,094VLANs(Port,Protocol,IEEE802.1Q)• 8,192ingressand1,024egressACLrules/Frontpanelportsand/VIM2-10G4Xmodule

CPU, Memory • 64bitMIPSProcessorDualCore,1GHzclock• 1GBECCDRAM• 256MBCompactFlash• USBportforexternalUSBflash

QoS, Rate Limiting • 8,192ingressbandwidthmeters/Frontpanelportsand/VIM2-10G4Xmodule

• Ingressandegressbandwidthpolicing/ratelimitingperflow/ACL

• 8QoSegressqueues/port• Egressbandwidthrateshapingperegressqueueandperport

• RateLimitingGranularity:8Kbps

LED Indicators• PerportstatusLEDincludingpowerstatus• SystemStatusLEDs:management,fanandpower

External Ports• 12-port100/1000BASE-XSFP,12-port100/1000BASE-XSFPand10/100/1000BASE-TCombo,2-port10GBASE-XXFP,1openslotforVIM2modules(SummitX480-24x)

• 44-port10/100/1000BASE-T,4-port100/1000BASE-XSFPand10/100/1000BASE-TCombo,1openslotforVIM2modules(SummitX480-48t)

• 48-port100/1000BASE-XSFP,1openslotforVIM2modules(SummitX480-48x)

• 1-portRS-232cSerial(controlport)• 110/100/1000BASE-Tout-of-bandmanagementport

External Ports for VIM2 Modules• 4-port10GBASE-XXFP(VIM2-10G4X)• 2-port20GSummitStack(VIM2-Summit-Stack)

• 2-port64GSummitStack(VIM2-SummitStack128)

Option Slot• SlotforVersatileInterfaceModule2(VIM2)availableforSummitX480-24x,SummitX480-48tandSummitX480-48x

Power Supply Support• SummitX480ACPSUandSummitX480DCPSU

Technical Specifications

Physical SpecificationsDimensions

Physical Dimensions • SummitX480-24xswitch• SummitX480-48xswitch• SummitX480-48tswitchHeight:1.73inches(4.4cm)Width:17.4inches(44.1cm)Depth:19.0inches(48.3cm)

• VIM2-SummitStackmodule• VIM2-10G4Xmodule• VIM2-SummitStack128moduleHeight:1.7inches(4.3cm)Width:5.2inches(13.2cm)Depth:9.9inches(25.2cm)

• SummitX480fanmoduleHeight:1.7inches(4.3cm)Width:5.2inches(13.2cm)Depth:9.9inches(25.2cm)

Weight• SummitX480-24xswitch20.9lb(9.5kg)• SummitX480-48xswitch22.7lb(10.3kg)• SummitX480-48tswitch21.2lb(9.6kg)

NOTE: Switch weights include installed fan module. They do not include installed VIM2 modules or PSUs.

• VIM2-SummitStackmodule2.03lb(0.92kg)• VIM2-10G4Xmodule2.76lb(1.25kg)• VIM2-SummitStack128module2.05lb(0.93kg)

• SummitX480fanmodule0.45lb(0.99kg)

Fan Speed• Minimumspeed4500RPM• Maximumspeed18000RPM

Operating Specifications• OperatingTemperatureRange:0°Cto45°C(32°Fto113°F)

• OperatingHumidity:10%to93%relativehumidity,non-condensing

• OperatingAltitude:0-3,000meters(9,850feet)

• OperationalShock(HalfSine):30m/s2(3g),11ms,60Shocks

• OperationalRandomVibration:3-500MHz@1.5grms

Storage & Transportation Conditions (Packaged)• TransportationTemperature:-40°Cto70°C(-40°Fto158°F)

• StorageandTransportationHumidity:10%to95%RH,non-condensing

• PackagedShock(HalfSine):180m/s2(18g),6ms,600shocks

• PackagedSineVibration:5-62Hz@Velocity5mm/s,62-500Hz@0.2G

• PackagedRandomVibration:5-20Hz@1.0ASDw/-3dB/oct.from20-200Hz

• 14dropsminonsides&corners@42”(<15kgbox)

Type L2 MAC L3 Host (IPv4/v6)

L3 LPM Route (IPv4/v6)

ACL(Ingress/Egress)

Lower Power Mode 32K 16K/8K 16K/8K 8K/1K

Default (Layer 2+Layer 3) 256K 16K/8K 256K/8K 8K/1K

Large Layer 2 Network Configuration 512K 16K/8K 16K/8K 8K/1K

Large Layer 3 Network Configuration 32K 16K/8K 512K/8K 8K/1K

Security Configuration 32K 16K/8K 16K/8K 60K/1K

Forwarding Tables and ACLsSummitX480providesflexibleconfigurationoptionsforvariousdeployments.

15

Extreme Networks Data Sheet: Summit X480 Series

Technical Specifications

Power Specifications

Summit X480-24xSummit X480-24x with No Installed VIM (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A

• Inputcurrent2.0A@100V(low-line)0.9A@240V(high-line)

• Heatdissipation,Watts,BTU195W,663BTU/hr

• Powerconsumption,Watts,BTU195W,663BTU/hr

Summit X480-24x with VIM2-SummitStack Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A

• Inputcurrent2.01A@100V(low-line)0.88A@240V(high-line)

• Heatdissipation,Watts,BTU200W,680BTU/hr

• Powerconsumption,Watts,BTU200W,680BTU/hr

Summit X480-24x with VIM2-10G4X Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A

• Inputcurrent2.4A@100V(low-line)1.1A@240V(high-line)

• Heatdissipation,Watts,BTU241W,823BTU/hr

• Powerconsumption,Watts,BTU241W,823BTU/hr

Summit X480-24x with VIM2-SummitStack128 Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.5A

• Inputcurrent2.08A@100V(low-line)0.91A@240V(high-line)

• Heatdissipation,Watts,BTU206W,704BTU/hr

• Powerconsumption,Watts,BTU206W,704BTU/hr

Summit X480-24x with No Installed VIM (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent3.25A@48V(low-line)2.6A@60V(high-line)

• Heatdissipation,Watts,BTU156W,532BTU/hr

• Powerconsumption,Watts,BTU156W,532BTU/hr

Summit X480-24x with VIM2-SummitStack Module (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent3.4A@48V(low-line)2.7A@60V(high-line)

• Heatdissipation,Watts,BTU161W,550BTU/hr

• Powerconsumption,Watts,BTU161W,550BTU/hr

Summit X480-24x with VIM2-10G4X Module (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent5.7A@48V(low-line)4.2A@60V(high-line)

• Heatdissipation,Watts,BTU246W,839BTU/hr

• Powerconsumption,Watts,BTU246W,839BTU/hr

Summit X480-24x with VIM2-SummitStack128 Module (DC Power Supply)• Nominalinputratings48V,7.5A• Inputcurrent3.5A@48V(low-line)2.8A@60V(high-line)

• Heatdissipation,Watts,BTU167W,569BTU/hr

• Powerconsumption,Watts,BTU167W,569BTU/hr

Summit X480-48xSummit X480-48x with No Installed VIM (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A

• Inputcurrent2.0A@100V(low-line)0.9A@240V(high-line)

• Heatdissipation,Watts,BTU200W,675BTU/hr

• Powerconsumption,Watts,BTU200W,675BTU/hr

Summit X480-48x with VIM2-SummitStack Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A

• Inputcurrent2.01A@100V(low-line)0.89A@240V(high-line)

• Heatdissipation,Watts,BTU203W,692BTU/hr

• Powerconsumption,Watts,BTU203W,692BTU/hr

Summit X480-48x with VIM2-10G4X Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A

• Inputcurrent2.3A@100V(low-line)1.0A@240V(high-line)

• Heatdissipation,Watts,BTU227W,774BTU/hr

• Powerconsumption,Watts,BTU227W,774BTU/hr

Summit X480-48x with VIM2-SummitStack128 Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,4.0A

• Inputcurrent2.04A@100V(low-line)0.89A@240V(high-line)

• Heatdissipation,Watts,BTU202W,688BTU/hr

• Powerconsumption,Watts,BTU202W,688BTU/hr

Summit X480-48x with No Installed VIM (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent3.3A@48V(low-line)2.6A@60V(high-line)

• Heatdissipation,Watts,BTU158W,540BTU/hr

• Powerconsumption,Watts,BTU158W,540BTU/hr

Summit X480-48x with VIM2-SummitStack Module (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent3.4A@48V(low-line)2.7A@60V(high-line)

• Heatdissipation,Watts,BTU163W,556BTU/hr

• Powerconsumption,Watts,BTU163W,556BTU/hr

Summit X480-48x with VIM2-10G4X Module (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent5.7A@48V(low-line)4.4A@60V(high-line)

• Heatdissipation,Watts,BTU246W,839BTU/hr

• Powerconsumption,Watts,BTU246W,839BTU/hr

Summit X480-48x with VIM2-SummitStack128 Module (DC Power Supply)• Nominalinputratings48V,8.0A• Inputcurrent3.4A@48V(low-line)2.7A@60V(high-line)

• Heatdissipation,Watts,BTU165W,562BTU/hr

• Powerconsumption,Watts,BTU165W,562BTU/hr

Summit X480-48tSummit X480-48t with No Installed VIM (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A

• Inputcurrent1.9A@100V(low-line)0.8A@240V(high-line)

• Heatdissipation,Watts,BTU182W,622BTU/hr

• Powerconsumption,Watts,BTU182W,622BTU/hr

Summit X480-48t with VIM2-SummitStack Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A

• Inputcurrent1.89A@100V(low-line)0.84A@240V(high-line)

• Heatdissipation,Watts,BTU187W,639BTU/hr

• Powerconsumption,Watts,BTU187W,639BTU/hr

16

Extreme Networks Data Sheet: Summit X480 Series

Technical Specifications

Summit X480-48t with VIM2-10G4X Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A

• Inputcurrent2.34A@100V(low-line)1.0A@240V(high-line)

• Heatdissipation,Watts,BTU232W,793BTU/hr

• Powerconsumption,Watts,BTU232W,793BTU/hr

Summit X480-48t with VIM2-SummitStack128 Module (AC Power Supply)• Nominalinputratings100to240V,50/60Hz,3.0A

• Inputcurrent1.89A@100V(low-line)0.84A@240V(high-line)

• Heatdissipation,Watts,BTU256W,871BTU/hr

• Powerconsumption,Watts,BTU256W,871BTU/hr

Summit X480-48t with No Installed VIM (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.1A@48V(low-line)2.4A@60V(high-line)

• Heatdissipation,Watts,BTU148W,503BTU/hr

• Powerconsumption,Watts,BTU148W,503BTU/hr

Summit X480-48t with VIM2-SummitStack Module (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.24A@48V(low-line)2.5A@60V(high-line)

• Heatdissipation,Watts,BTU153W,520BTU/hr

• Powerconsumption,Watts,BTU153W,520BTU/hr

Summit X480-48t with VIM2-10G4X Module (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.1A@48V(low-line)2.4A@60V(high-line)

• Heatdissipation,Watts,BTU148W,503BTU/hr

• Powerconsumption,Watts,BTU148W,503BTU/hr

Summit X480-48t with VIM2-SummitStack128 Module (DC Power Supply)• Nominalinputratings48V,7.0A• Inputcurrent3.2A@48V(low-line)2.5A@60V(high-line)

• Heatdissipation,Watts,BTU153W,522BTU/hr

• Powerconsumption,Watts,BTU153W,522BTU/hr

Power Supply Units

Summit X480 AC PSUFor use with the Summit X480-24x, Summit X480-48x, and Summit X480-48t switches

Physical Specifications• Height:1.57inches(4.0cm)• Width:4.8inches(12.3cm)• Depth:13.31Inches(33.8cm)• Weight3.64lb(1.65kg)

Power Specifications• Voltageinputrange90to264V• Nominalinputratings100to240V,50to60Hz,8A

• Nominalinputcurrentatfullloads12A@90V(low-line)5A@230V(high-line)

• Linefrequencyrange47to63Hz• Maximuminrushcurrent15A• Output12V,37Amax,450Watts3.3V,3Amax,9.9Watts

• MaximumcontinuousDCoutputshallnotexceed450Watts

• PowersupplyinputsocketIEC320C14• PowercordinputplugIEC320C13• Powersupplycordgauge18AWG(0.75mm2)upto6feetor2metersor16AWG(1.0mm2)over6feet

• Efficiency84%typicalatfullload,highline

Summit X480 DC PSUFor use with the Summit X480-24x, X480-48x, and X480-48t switches

Physical Specifications• Height:1.57inches(4.0cm)• Width:4.8inches(12.3cm)• Depth:13.31Inches(33.8cm)• Weight2.58lb(1.17kg)

Power Specifications• NominalInput-48to-60VDC,24A• DCVoltageInputRange-40to-75V• MaximumInputAmperages13.5A@40V11.2A@48V7.5A@72V

• InrushCurrent10Apeak• InrushEnergy1.5A2S• Minimumwiresize14AWG(1.5mm2)copperstranded

• DCOutput12V,36.7A/3.3V,3.0A• DCOutputPower(W)450W

All Summit X480 Series Switches

Regulatory/SafetyNorth American Safety of ITE • UL60950-11stEd.,ListedDevice(U.S.)• CSA22.2#60950-1-031stEd.(Canada)• ComplieswithFCC21CFR1040.10(U.S.LaserSafety)

• CDRHLetterofApproval(U.S.FDAApproval)

European Safety of ITE • EN60950-1:2006• EN60825-1+A2:2001(LasersSafety)• TUV-RGSMarkbyGermanNotifiedBody• 2006/95/ECLowVoltageDirective

International Safety of ITE • CBReport&CertificateperIEC60950-1:2006+NationalDifferences

• AS/NZS60950-1(Australia/NewZealand)

EMI/EMC StandardsNorth America EMC for ITE • FCCCFR47part15ClassA(U.S.)• ICES-003ClassA(Canada)

European EMC Standards • EN55022:2006ClassA• EN55024:A2-2003ClassAincludesIEC61000-4-2,3,4,5,6,11

• EN61000-3-2,8-2006(Harmonics)• EN61000-3-31995+A2:2005(Flicker)• ETSIEN300386v1.3.3,2005-04(EMCTelecommunications)

• 2004/108/ECEMCDirective

International EMC Certifications • CISPR22:2006Ed5.2,ClassA(InternationalEmissions)

• CISPR24:A2:2002ClassA(InternationalImmunity)

• EC/EN61000-4-2:2008ElectrostaticDischarge,8kVContact,15kVAir,CriteriaA

• EC/EN61000-4-3:2008RadiatedImmunity10V/m,CriteriaA

• EC/EN61000-4-4:2005TransientBurst,1kV,CriteriaA

• IEC/EN61000-4-5:2005Surge,2kVL-L,2kVL-G,Level3,CriteriaA

• IEC/EN61000-4-6:2007ConductedImmunity,0.15-80MHz,10V/munmod.RMS,CriteriaA

• EC/EN61000-4-11:2004PowerDips&Interruptions,>30%,25periods,CriteriaC

Country Specific• VCCIClassA(JapanEmissions)• ACMA(C-Tick)(AustraliaEmissions)• CCCMark• KCCMarkEMCApproval(Korea)

Telecom Standards • EN/ETSI300386:2005-04(EMCTelecommunications)

• EN/ETSI300019(EnvironmentalforTelecommunications)

• NEBSLevel3complianttoportionsofGR-1089Issue4&GR-63Issue3asdefinedinSR3580withexceptiontofilterrequirement

• MEF9• MEF14

IEEE 802.3 Media Access Standards • IEEE802.3ab1000BASE-T• IEEE802.3z1000BASE-X• IEEE802.3ae10GBASE-X

17

Extreme Networks Data Sheet: Summit X480 Series

Technical Specifications

Environmental Standards • EN/ETSI300019-2-1v2.1.2(2000-09)–Class1.2Storage

• EN/ETSI300019-2-2v2.1.2(1999-09)–Class2.3Transportation

• EN/ETSI300019-2-3v2.1.2(2003-04)–Class3.1eOperational

• EN/ETSI300753(1997-10)–AcousticNoise• ASTMD3580RandomVibrationUnpackaged1.5G

Warranty • Ltd.1-yearonHardware• 90-daysonSoftware• Forwarrantydetails,visitwww.extremenetworks.com/go/warranty

18

Extreme Networks Data Sheet: Summit X480 Series

Ordering Information

Part Number Name Description

16301 SummitX480-48t 4810/100/1000BASE-T,4100/1000BASE-XunpopulatedSFP(shared),NoPSUwithtwounpopulatedPSUslots,oneVIM2slot,ExtremeXOSAdvancedEdgelicense

16303 SummitX480-24x 24100/1000BASE-XunpopulatedSFP,1210/100/1000BASE-T(shared),2unpopulatedXFPports,NoPSUwithtwounpopulatedPSUslots,oneVIM2slot,ExtremeXOSAdvancedEdgelicense

16304 SummitX480-48x 48100/1000BASE-XunpopulatedSFP,NoPSUwithtwounpopulatedPSUslots,oneVIM2slot,ExtremeXOSAdvancedEdgelicense

16311 VIM2-SummitStack VIM2-SummitStack,2SummitStackstackingports

16312 VIM2-10G4X VIM2-10G4X,410GBASE-XXFPports

16313 VIM2-SummitStack128 VIM2-SummitStack128,2x64Gstackingports

16315 VIM2-SummitStack-V80 VIM2-SummitStack-V80,2x40Gstackingports

16321 SummitX480CoreLicense ExtremeXOSCoreLicenseforSummitX480seriesswitches

16322 SummitX480MPLSFeaturePack

ExtremeXOSMPLSFeaturePackforSummitX480seriesswitches

11011 DirectAttachFeaturePack DirectAttachFeaturePackforSummitX450a/X460/X480,SummitX650andBlackDiamond8800SerieswithExtremXOS12.5.1orGreater

10916 SummitX480/X650FANModule

FANmoduleforSummitX480andSummitX650seriesswitches,spare

10917 SummitX480ACPSU ACPowerSupplymoduleforSummitX480seriesswitches

10918 SummitX480DCPSU DCPowerSupplymoduleforSummitX480seriesswitches

10121 10GBASE-SRXFP 10GBASE-SRXFPTransceiver,850nm,upto300monMultimodeFiber,LCConnector

10122 10GBASE-LRXFP 10GBASE-LRXFPTransceiver,1310nm,upto10kmonSingle-modeFiber,LCConnector

10124 10GBASE-ERXFP 10GBASE-ERXFPTransceiver,1550nmupto40kmonSingle-modeFiber,LCConnector

10125 10GBASE-ZRXFP 10GBASE-ZRXFPTransceiver,1550nm,upto80kmonSingle-modeFiber,LCConnector

10200 TunableDWDMXFP 10GigabitEthernetXFPTunableDWDMmodule,C-band,SMF80km,LCconnector

10051 1000BASE-SXSFP 1000BASE-SXSFP,LCConnector

10052 1000BASE-LXSFP 1000BASE-LXSFP,LCConnector

10053 1000BASE-ZXSFP 1000BASE-ZXSFP,ExtraLongDistanceSMF70km/21dBBudget,LCConnector

10056 1000BASE-BX-DSFP 1000BASE-BX-DSFP,SMF(1490nmTX/1310nmRXWavelength)

10057 1000BASE-BX-USFP 1000BASE-BX-USFP,SMF(1310nmTX/1490nmRXWavelength)

10060 100FX/1000LXSFP1 100FX/1000LXSFP,SMF,LCConnector(RequiresMCPand6dBAttenuatorfor100FX-MMFOperation)

10063 100FXSFP1 100FXSFP,MMF,LCConnector

10064 1000BASE-LX100SFP 1000BASE-LX100SFP,ExtraLongDistanceSMF100km/30dBBudget,LCConnector

10065 10/100/1000BASE-TSFP1 10/100/1000BASE-T,SFP,CAT5cable100m,RJ-45Connector

10067 100BASE-FXSFP 100MSFP,100FXMMF,(1310nm,2kmmultimodetransmission)LCconnector

10066 100BASE-LX10SFP 100MSFP,100LX10SMF,(1310nm10kmsinglemodetransmission)LCconnector

10058 100BASE-BX-DSFP 100MSFP,100BASE-BX-D,SMF(1550nmTX/1310nmRXwavelength),100Mbpsbidirectional

10059 100BASE-BX-USFP 100MSFP,100BASE-BX-U,SMF(1310nmTX/1550nmRXwavelength),100Mbpsbidirectional

1NotsupportedonComboports

Extreme Networks Data Sheet: Summit X480 Series

Make Your Network Mobile

© 2011 Extreme Networks, Inc. All rights reserved. Extreme Networks, the Extreme Networks logo, BlackDiamond, Direct Attach, Extreme Standby Router Protocol, ExtremeXOS, Ex-tremeXOS ScreenPlay, Ridgeline, Summit, SummitStack, UniStack and XNV are either registered trademarks or trademarks of Extreme Networks, Inc. in the United States and/or other countries. sFlow is the property of InMon Corporation. Specifications are subject to change without notice. 1625_09 05/11

extremenetworks.com

Corporateand North AmericaExtreme Networks, Inc.3585 Monroe Street Santa Clara, CA 95051 USAPhone +1 408 579 2800

Europe, Middle East, Africaand South AmericaPhone +31 30 800 5100

Asia PacificPhone +65 6836 5437

JapanPhone +81 3 5842 4011

Ordering Information

Part Number Name Description

10312 QSFP+passivecoppercable,1.0M

QSFP+passivecoppercable,1.0M

10315 QSFP+activefibercable,10M

QSFP+activefibercable,10M

10318 QSFP+activefibercable,100M

QSFP+activefibercable,100M

16106 StackingCable,0.5M SummitStack/UniStack™StackingCable,0.5M

16107 StackingCable,1.5M SummitStack/UniStackStackingCable,1.5M

16108 StackingCable,3.0M SummitStack/UniStackStackingCable,3.0M

16105 StackingCable,5.0M2 SummitStackStackingCable,5.0M

17030 StackingCable64G,1.0M SummitStack128StackingCable,1.0M

17026 StackingCable128Gto64G,1.0M

ConversioncableforSummitStack256andSummitStack128,1.0M

17034 StackingCable128Gto20G,1.0M

ConversioncableforSummitStack256andSummitStack,1.0M

17038 StackingCable64Gto20G,1.0M

ConversioncableforSummitStack128andSummitStack,1.0M

2NotsupportedwhenusingwithSummitX650andUniStack