status of the zero energy deuterium (zed-2) research...

Post on 15-Jun-2020

9 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

-1-UNRESTRICTED / ILLIMITÉ

Status of the Zero Energy Deuterium (ZED-2)

Research ReactorJ. HornerTRTR ConferenceSan Diego, CaliforniaSeptember 16th to 21st 2017

-2-UNRESTRICTED / ILLIMITÉ

Presentation Overview• ZED-2 Background

• ZED-2 Experiments

• System Health Program Background

• System Health Program Implementation

• System Health Program Upgrades

-3-UNRESTRICTED / ILLIMITÉ

ZED-2 BackgroundCanadian Nuclear Laboratories (CNL) Location

Chalk River

-4-UNRESTRICTED / ILLIMITÉ

• First Criticality: September 7, 1960

• Maximum Power: 200 W (indicated), 700 W (thermal)

• Maximum Neutron Flux: 1×109 nHcm-2Hs-1

• Moderator: Heavy Water

• Coolant: Air, Heavy Water, Light Water

• Fuel: NU, LEU, Other Mixed Oxides

ZED-2 BackgroundZED-2 Overview

-5-UNRESTRICTED / ILLIMITÉ

ZED-2 BackgroundZED-2 Facility Layout

Top Shields

Support Beams (15)

Calandria

Graphite Reflector

Dump Valves (3)

Dump Tanks (3)

Control Room

-6-UNRESTRICTED / ILLIMITÉ

ZED-2 BackgroundZED-2 Control Room

-7-UNRESTRICTED / ILLIMITÉ

ZED-2 BackgroundZED-2 Calandria

-8-UNRESTRICTED / ILLIMITÉ

• Natural UO2 Bundles

• 7, 19, 28, 37, 43 element

• Uranium Carbide

• Uranium Silicide

• Uranium Metal

• Mixed Oxides

• Pu-U (Depleted)

• U233-Th

• Pu-Th

• Bundles with absorber elements

• Enriched or reprocessed UO2 bundles (LEU, RU)

ZED-2 ExperimentsFuel Bundles

-9-UNRESTRICTED / ILLIMITÉ

ZED-2 ExperimentsCore Configurations

-10-UNRESTRICTED / ILLIMITÉ

• Critical Height Measurements

• Reactor Physics Code Validations

• Reactivity Transient Measurements

• Nuclear Data for Thoria Based Fuels

• Flux Perturber Experiments

• 3-D Kinetics Measurements

ZED-2 ExperimentsOngoing Experiments

-11-UNRESTRICTED / ILLIMITÉ

ZED-2 ExperimentsFlux Maps

-12-UNRESTRICTED / ILLIMITÉ

ZED-2 ExperimentsFlux Maps

Radial Distance (cm)

-120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120

Re

lative F

oil

Activatio

n

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

Fitted Bessel Function

Copper Activation

Indium Activation

Copper Activation in Reflector

Experiment

Radial DataRadial Distance (cm)

-120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120R

ela

tive

Cu

Foil

Activa

tio

n0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

MCNP

Measurement

Comparison to Calculation

-13-UNRESTRICTED / ILLIMITÉ

ZED-2 ExperimentsFlux Maps

Axial Distance Above Floor (cm)

15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185

Rela

tive F

oil

Activation

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

Fitted Cosine

Copper Activation

Indium Activation

Axial Distance Above Floor (cm)

15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185R

ela

tive C

u F

oil

Activation

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

MCNP

Measurement

Experiment Comparison to Calculation

Axial Data

-14-UNRESTRICTED / ILLIMITÉ

• Calibrate 30 Vanadium Detectors per reactor operation

• Calibrate an entire CANDU 6 Reactor fleet in less than 1 week

• ZED-2 Counting Laboratory aids in calibrating detectors

ZED-2 ExperimentsSelf Powered Flux Detector Calibrations

-15-UNRESTRICTED / ILLIMITÉ

• Low Flux (Maximum 109 nHcm-2Hs-1)

• Same Day Handling

• ZED-2 Counting Laboratory Support

ZED-2 ExperimentsIon Chamber Calibrations

Signal and High Voltage Cables

Positioning Clamp

Ion Chamber

Lead Weight

Suspension Cable

-16-UNRESTRICTED / ILLIMITÉ

• In operation for over 57 years with no plan to decommission

• Irradiation damage insignificant

• Aging electronic safety system

• Ensure all capabilities are maintained

System Health Program BackgroundSystem Health Program Implementation Reasoning

-17-UNRESTRICTED / ILLIMITÉ

• Four Main Documents for each System:

• System Performance Monitoring Plan

• Walkdown Plan

• Walkdown Report

• System Health Report

System Health Program BackgroundSite System Health Program

System Health

Program

Aging Management

Obsolescence Management

Configuration Management

-18-UNRESTRICTED / ILLIMITÉ

• System Performance Monitoring Plan:

• Defines System Boundaries and Functions

• Lists Maintenance Activities, Drawings, and Documentation

• Assesses Aging Management Degradation Mechanisms

• Evaluates Obsolescence Management Issues

• Lists Spare Parts Inventory Levels

System Health Program BackgroundSite System Health Program

-19-UNRESTRICTED / ILLIMITÉ

• Walkdown Plan:

• Lists Hazards

• Lists Components and Component Locations

• Walkdown Report:

• Describes System Upgrades

• Confirms Maintenance Activities

• Evaluates Configuration Management Issues

• Confirms Spare Parts Inventory Levels

System Health Program BackgroundSite System Health Program

-20-UNRESTRICTED / ILLIMITÉ

• System Health Report:

• Evaluates the system based on Performance Indicators

• Recommends a strategy for improving the system reliability

• Presented to Management to tailor the resources required

System Health Program BackgroundSite System Health Program

-21-UNRESTRICTED / ILLIMITÉ

• 16 ZED-2 Safety Related Systems

• 19 ZED-2 Not Safety Related Systems

• 8 System Health Program Systems

System Health Program ImplementationZED-2 System Classification

-22-UNRESTRICTED / ILLIMITÉ

1. Safety System Trip Circuits

2. Radiation Monitoring Systems

3. Fuel Storage and Support Structures

4. Moderator Systems

5. Engineered Manual Controls

6. Site Systems

7. Process Air and Ventilation Systems

8. Out of Service Systems

System Health Program ImplementationSystem Health Program Systems

-23-UNRESTRICTED / ILLIMITÉ

Completed

• Safety System Trip Relays & Pump Timers

• 58 Safety System Auxiliary Relays

• Log Count Rate/ Log Power Recorder

• Back Off Amplifier Recorder

• Comparator Meter Relays

System Health Program UpgradesSafety System Trip Circuits

-24-UNRESTRICTED / ILLIMITÉ

In Progress

• Voltage Monitors

• Fission Chamber Replacement

• Start-Up Amplifier Overhaul

System Health Program UpgradesSafety System Trip Circuits

-25-UNRESTRICTED / ILLIMITÉ

In Progress

• Slow Neutron Monitors

System Health Program UpgradesRadiation Monitoring Systems

Fuel Storage and Support Structures

Completed

• Steel Structure Support

• Fuel Storage Cabinets Anchored

-26-UNRESTRICTED / ILLIMITÉ

Completed

• Dump Valve Magnets, Pneumatic Actuators, Air Regulators, Relays, Capacitors

• Drain Solenoid Control Valves

In Progress

• Accurate Height Probe Control Relays

• Control Room Pushbuttons and Indicators

System Health Program UpgradesModerator Systems

-27-UNRESTRICTED / ILLIMITÉ

• System Health Program is well underway with a positive impact on equipment reliability and reducing downtime

• Experiments are designed to validate reactor physics analysis codes and nuclear data libraries

• Excellent facility for reactor lattice properties

• Upcoming commercial work for calibrations

ZED-2 Reactor Status SummarySummary

-28-UNRESTRICTED / ILLIMITÉ

Thank you.Questions?

Jake HornerR&D Facilities Specialist

ZED-2 Reactorjacob.horner@cnl.ca