state employees'documents.brunswickcountync.gov/bcms/0/edoc/963474...g002 code summary civil c1...
Post on 11-Jun-2020
3 Views
Preview:
TRANSCRIPT
EARTH
GRAVEL
CONCRETE
SAND
CONCRETE
MASONRY UNITS
SOLID CONCRETE
MASONRY UNITS
BRICK
STONE
STUCCO
EXTERIOR INSULATED
FINISH SYSTEM
RIGID INSULATION
BATT INSULATION
METAL (SECTION)
PLYWOOD
WOOD - FINISH
WOOD - ROUGH
WOOD - BLOCKING
AL., ALUM.
AC.
A.P.
A.F.F.
BD.
BLDG.
B.M.
BRG.
BSMT.
CAB.
C.B.
C.T.
C.H.
C.J.
CL
CLG.
CLOS.
CLR.
C.M.U.
COL.
CONC.
CONST.
CONT.
CORR.
CPT.
C.R.
D.A.
DET.
D.F.
DBL.
DIA.
DIM.
DISP.
DR.
DW
DS
DWG
EA.
E.J.
EL., ELEV.
ELEC.
EQ.
EQUIP.
E.W.C.
EXIST.
EXP
EXT.
F.C.
F.C.U.
F.D.
FDN.
ACOUSTIC
ALUMINUM
ACCESS PANEL
ABOVE FINISHED FLOOR
BOARD
BUILDING
BENCH MARK
BEARING
BASEMENT
CABINET
CHALKBOARD
CERAMIC TILE
CEILING HEIGHT
CONTROL JOINT
CENTER LINE
CEILING
CLOSET
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONSTRUCTION
CONTINUIOUS
CORRIDOR
CARPET
COLD ROLLED
DISTURBED AREA
DETAIL
DRINKING FOUNTAIN
DOUBLE
DIAMETER
DIMENSION
DISPENSER
DOOR
DRYWALL
DOWNSPOUT
DRAWING
EACH
EXPANSION JOINT
ELEVATION
ELECTRIC
EQUAL
EQUIPMENT
ELECTRIC WATER COOLER
EXISTING
EXPANSION
EXTERIOR
FIRE CODE
FAN COIL UNIT
FLOOR DRAIN
FOUNDATION
F.E.C.
F.F.,FIN.F.
F.O.S.
FTG.
FURR.
GA.
G.B.
GL.
GR. STOP
G.W.B.
GYP. BD.
H, HT., HGT.
H.C.
HDW.
H.M.
FIRE EXTIGUISHER BRACKET
HR.
H.P.
I.D.
INSUL.
JAN.
JST.
JT.
LAM.
LAV.
L.P.
M.
MACH.
MAINT.
MAS.
MAT.
MAX.
M.C.
MECH.
MET., MTL.
MFG.
MIN.
M.O.
M.S.
MTD.
N.C.
N.I.C.
NO.
N.T.S.
O.C.
O.D.
OFF.
OPNG.
PART.
PL.
PLY.
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FOOTING
FACE OF STUD
FURRING
GAUGE
GRAB BAR
GLASS
GRAVEL STOP
GYPSUM WALLBOARD
GYPSUM BOARD
HEIGHT
HANDICAPPED
HARDWARE
HOLLOW METAL
HOUR
HIGH POINT
INSIDE DIAMETER
INSULATION
JANITOR
JOIST
JOINT
LAMINATE
LAVATORY
LOW POINT
MEN
MACHINE
MAINTENANCE
MASONRY
MATERIALS
MAXIMUM
MEDICINE CABINET
MECHANICAL
METAL
MANUFACTURER
MINIMUM
MOUNTED
MASONRY OPENING
NUMBER
OFFICE
METAL SHELVING
NON COMBUSTIBLE
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OPENING
PARTITION
PLATE
PLYWOOD
PNL.
P&S
P.S.
PTD.
P.T.D.
R.D.
REC.
RECPT.
REF.
REQD.
R.L.
RM.
R.O.
R&S
S.D.
SECT.
S.G.F.T.
S.H.
SHT.
SIM.
S.M.
S.P.
S.S.
S/S
ST.
STOR.
STRUCT.
SUSP.
SYN. FL.
TACKBD., T.B.
TEL.
T&G
THRESH.
T.OF B.
TOM
TOS
T.P.
TYP.
U.L.
V.C.T.
VERT.
VEST.
V.R.S.
W
W/
W.C
WAIN.
WARD.
W.B.
WD.
WL.
W.M.
WWM
PANEL
POLE AND SHELF
PROJECTION SCREEN
PAINTED
PAPER TOWEL DISPENSER
ROOF DRAIN
RECESSED
RECEPTIONIST
REFRIGERATOR
REQUIRED
RAIN LEADER
ROOM
ROUGH OPENING
ROD AND SHELF
SOAP DISPENSER
SECTION
SHOWER HEAD
SHEET
SIMILAR
SURFACE MOUNTED
STAND PIPE
SERVICE SINK
STAINLESS STEEL
STEEL
STORAGE
STRUCTURAL
SUSPENDED
SYNTHETIC FLOORING
TACKBOARD
TELEPHONE
TONGUE AND GROOVE
THRESHOLD
TOP OF BEARING
TOP OF MASONRY
TOP OF STEEL
TOILET PAPER HOLDER
TYPICAL
UNDERWRITERS LABORATORIES
VINYL COMPOSITION TILE
VERTICAL
VESTIBULE
VINYL REDUCING STRIP
WOMEN
WITH
WAINSCOT
WARDROBE
WOOD
WHITE BOARD
WATER CLOSET
WALL
WALL MOUNTED
WELDED WIRE MESHF.E. FIRE EXTIGUISHER
F.E.B.
G.M.U. GLAZED MASONRY UNIT
EIFS EXT. INSUL. FINISH SYSTEM
F.V. FIELD VERIFY
X
X
Y
XXX
X
Y
X
X
X
2
1
4
3
A400
X
COLUMN GRID LINES
SECTIONS
DETAILS IN PLAN / SECTION
INTERIOR ELEVATIONS
NOTE
REVISION
WALL TYPE
WINDOW TYPE
DOOR NUMBER
ROOM NUMBER
FIRE RATED WALL TYPE
STRUCT. GLAZED FACING TILE
XXX
STATE EMPLOYEES'
CREDIT UNION
923 SEASIDE ROAD SW
OCEAN ISLE BEACH, NC 28469
1. DIMENSIONS ARE FROM FACE OF MASONRY OR METAL STUD UNLESS NOTED OTHERWISE.
2. CHASE WALLS SHALL MATCH ADJACENT CONSTRUCTION UNLESS OTHERWISE SHOWN BY WALL TYPE, TYP.
3. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY VARIATIONS, DISCREPANCIES OR FIELD ALTERATIONS TO THESE DESIGN PRIOR TO CONSTRUCTION.
DISCREPANCIES OR OTHER SUCH CONDITIONS NOT REPORTED PRIOR TO CONSTRUCTION MAY NOT BE USED AS GROUNDS FOR ADDITIONAL EXPENSE CLAIMS BY THE CONTRACTOR NECESSARY TO
ADEQUATELY COMPLETE THE WORK.
4. ANY ITEMS NOT SPECIFICALLY SHOWN ON THE DRAWINGS, BUT REASONABLY INCIDENTAL TO AND NECESSARY FOR THE SATISFACTORY COMPLETION OF THE PROJECT IN ACCORDANCE WITH INDUSTRY
STANDARDS, ARE INCLUDED WITHIN THE INTENT OF THESE DESIGN DRAWINGS.
5. CODES: ALL WORK ON THIS PROJECT SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES, ORDINANCES, REGULATIONS AND ANY ADDITIONAL REQUIREMENT SO STATED IN ANY LAW,
ORDINANCE OR REGULATION PERTAINING TO CONSTRUCTION WITHIN THE SAID LIMITS OF THE AUTHORITY HAVING JURISDICTION OVER THE PROPOSED WORK, ZONING, ARCHITECTURAL, STRUCTURAL,
MECHANICAL, PLUMBING, ELECTRICAL ENERGY CONSERVATION AND FIRE. CONFORMITY TO ALL CODES APPLICABLE TO THIS PROJECT SHALL BE THE CONTRACTORS RESPONSIBILITY.
6. PROPER ASSEMBLY, INSTALLATION, AND OPERATION OF ALL MATERIALS, COMPONENTS, SYSTEMS AND FINISHES ARE THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
7. COMPONENTS FOR CONSTRUCTION SAFETY ARE NOT INDICATED IN THESE DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL RULES AND REGULATIONS OF THE
OCCUPATIONAL SAFETY AND HEALTH ACT DURING ALL CONSTRUCTION.
8. ALL PLUMBING FIXTURES, LAVATORY ACCESSORIES, MOUNTING HEIGHTS AND NECESSARY FLOOR CLEARANCES SHALL COMPLY WITH ANSI A117.1 AND THE REQUIREMENTS SET FORTH BY THE AMERICANS
WITH DISABILITIES ACT.
ABBREVIATIONS
DRAWING KEYS
SYMBOLS OF MATERIALS
LIST OF DRAWINGS
GENERAL
G001 COVER SHEET
G002 CODE SUMMARY
CIVIL
C1 SITE PLAN
CONSTRUCTION DOCUMENTS
FEBRUARY 14, 2017
BECKER MORGAN GROUP, INC.
CTT CONSULTING ENGINEERS
CBHF ENGINEERS, PLLC
ARCHITECT
CIVIL ENGINEER
PM&E ENGINEER
GENERAL NOTES
DESIGN TEAM
LS101 LIFE SAFETY PLAN
ARCHITECTURAL
A101 FLOOR PLAN
STRUCTURAL
S1 STRUCTURAL RENOVATION PLAN
ELECTRICAL
E-001 ELECTRICAL NOTES, LEGEND
E-002 ELECTRICAL SCHEDULES
E-101 ELECTRICAL FLOOR PLAN
G001
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
BE
CK
ER
MO
RG
AN
GR
OU
P, I
NC
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
E
AL
P
RA
C
NN
IH
TU
NI
CT
G
ER
91
0.3
41
.7
60
0
Wilm
in
gto
n, N
C
32
05
R
an
da
ll P
kw
y, S
uite
2
11
Wilm
in
gto
n, N
C 2
84
03
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
I-A
I-B
II-A
II-B
IIIIII
H-1 DETONATE
I-1
H-2 DEFLAGRATE
I-2
A-1 A-2
I-3
H-3 COMBUST
A-3
I-4
H-4 HEALTH
F-1 MODERATE F-2 LOW
H-5 HPM
A-4 A-5
I-31 2 3 4 5
R-1
S-1 MODERATE S-2 LOW
R-2 R-3 R-4
I
I
I
(Ie)
(Is)
(Iw)
LEAD DESIGN PROFESSIONAL:
2012 EDITION OF NC CODE FOR:
ALLOWABLE AREA:
BASIC BUILDING DATA:
.
.
.
.
.
.
2,713
.
.
.
.
.
.
N/A .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.. ...
.. ...
.. ...
.. ...
.. ...
.. ...
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
REQUIRED
NEW
EXISTING
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
Mark T. Arcuri
Ernest W. Olds
.
.
.
.
.
.
24419
10595
.
.
.
.
.
.
.
910.397.3939
910.341.7600
.
.
.
.
.
. .
+< 1
+ + = < 1
2
f
s
s
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
. .
..
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
* INDICATE SECTION NUMBER PERMITTING REDUCTION
TENANT SEPARATION
SMOKE BARRIER SEPARATION
PARTY/FIRE WALL SEPARATION
OCCUPANCY SEPARATION
CORRIDOR SEPARATION
SHAFTS - OTHER
SHAFTS - EXIT
BEAMS AND JOISTS
INCLUDING SUPPORTING
ROOF CONSTRUCTION
BEAMS AND JOISTS
INCLUDING SUPPORTING
FLOOR CONSTRUCTION
.
INTERIOR
SOUTH
WEST
EAST
NORTH
EXTERIOR
AND PARTITIONS
NON-BEARING WALLS
INTERIOR
SOUTH
WEST
EAST
NORTH
EXTERIOR
BEARING WALLS
GIRDERS, TRUSSES
INCLUDING COLUMNS,
STRUCTURAL FRAME,
(FEET)
DISTANCE
SEPARATION
FIRE
.
.
.
.
.
.
.
.
RATING
REDUCTION)
REQ'D PROVIDED
(W/ *
SHEET #
AND
DETAIL #
ASSEMBLY
RATED
FOR
DESIGN #
PENETRATION
RATED
FOR
DESIGN #
JOINTS
RATED
FOR
DESIGN #
BUILDING ELEMENT
LIFE SAFETY PLAN SHEET #
FIRE PROTECTION REQUIREMENTS:
. . . ..
. . . . .
. . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
BUILDING HEIGHT IN STORIES STORIES STORIES + 1 = STORIES....
BUILDING HEIGHT IN FEET FEET.
FEET = H + 20' =.
FEET.
TYPE OF CONSTRUCTION TYPE TYPE.
(TABLE 503)
ALLOWABLE
SPRINKLERS
INCREASE FOR
REFERENCE
CODE
PLANS
SHOWN ON
.
ALLOWABLE HEIGHT:
CONTROL TOWERS MUST COMPLY WITH 412.1.2.
5. THE MAXIMUM AREA OF OPEN PARKING GARAGES MUST COMPLY WITH 406.3.5. THE MAXIMUM AREA OF AIR TRAFFIC
4. MAXIMUM BUILDING AREA = TOTAL NUMBER OF STORIES IN THE BUILDING x E (506.4)
3. UNLIMITED AREA APPLICABLE UNDER CONDITIONS OF SECTION 507
B. SINGLE-STORY BUILDING = 300 PERCENT
A. MULTI-STORY BUILDING = 200 PERCENT
2. THE SPRINKLER INCREASE PER SECTION 506.3 IS AS FOLLOWS:
E. PERCENT OF FRONTAGE INCREASE = 100 [F/P - 0.25] x W/30 = (%)
D. W = MINIMUM WIDTH OF PUBLIC WAY = (W)
C. RATIO (F/P) = (F/P)
B. TOTAL BUILDING PERIMETER = (P)
A. PERIMETER WHICH FRONTS A PUBLIC WAY OR OPEN SPACE HAVING 20 FEET MINIMUM WIDTH = (F)
1. FRONTAGE AREA INCREASES FROM SECTION 506.2 ARE COMPUTED THUS:
STORY NO.
AND USE
DESCRIPTION
(ACTUAL)
PER STORY
BLDG AREA
(A) (B)
TABLE 503
AREA
(C)
AREA FOR
OPEN SPACE
INCREASE INCREASE
SPRINKLER
AREA FOR
(D)
UNLIMITED
AREA OR
ALLOWABLE
(E)
3
AREA
4
BUILDING
MAXIMUM
(F)
1
5
ALLOWABLE AREA OF OCCUPANCY A ALLOWABLE AREA OF OCCUPANCY B
ACTUAL AREA OF OCCUPANCY BACTUAL AREA OF OCCUPANCY A
ACTUAL FLOOR AREA OF EACH USE DIVIDED BY THE ALLOWABLE FLOOR AREA FOR EACH USE SHALL NOT
FOR EACH STORY, THE AREA OF THE OCCUPANCY SHALL BE SUCH THAT THE SUM OF THE RATIOS OF THE
SEPARATED USE (508.4) - SEE BELOW FOR AREA CALCULATIONS
THE MOST RESTRICTIVE TYPE OF CONSTRUCTION, SO DETERMINED, SHALL APPLY TO THE ENTIRE BUILDING
HEIGHT AND AREA LIMITATIONS FOR EACH OF THE APPLICABLE OCCUPANCIES TO THE ENTIRE BUILDING.
THE REQUIRED TYPE OF CONSTRUCTION FOR THE BUILDING SHALL BE DETERMINED BY APPLYING THE
NON-SEPARATED USE (508.3)
MIXED OCCUPANCY: NO YES SEPARATION: HR. EXCEPTION:
SPECIAL PROVISIONS: 509.2 509.3 509.4 509.5 509.6 509.7 509.8
UTILITY AND MISCELLANEOUS
STORAGE
MERCANTILE
INSTITUTIONAL
HAZARDOUS
BUSINESS
ASSEMBLY
RESIDENTIAL
USE CONDITION
FACTORY
HIGH-PILED
OCCUPANCY:
BASEMENT
1ST FLOOR
MEZZANINE
2ND FLOOR
3RD FLOOR
4TH FLOOR
5TH FLOOR
6TH FLOOR
FLOOR EXISTING (SQ. FT.)
TOTAL
GROSS BUILDING AREA:
BUILDING HEIGHT:
FIRE DISTRICT:
STANDPIPES:
SPRINKLERS:
NO
NO
NO YES
YES
YES (Primary)
FEET
WET DRY
NFPA 13DNFPA 13RNFPA 13
CLASS
CONSTRUCTION TYPE:
NEW CONSTRUCTION
RECONSTRUCTION
UPFIT
ALTERATION
OTHER
RETAINING WALLS >5' HIGH
STRUCTURAL
SPRINKLER-STANDPIPE
MECHANICAL
PLUMBING
FIRE ALARM
ELECTRICAL
CIVIL
ARCHITECTURAL
DESIGNER FIRM NAME LICENSE # TELEPHONE #
CODE ENFORCEMENT JURISDICTION: CITY COUNTY
STATEPRIVATECITY/COUNTYOWNED BY:
OWNER OR AUTHORIZED AGENT: PHONE #:
PROPOSED USE:
ADDRESS:
NAME OF PROJECT:
TOTAL
REQUIRED PROVIDED
PROVIDED
TOTAL #
ACCESSIBLE
# OF ACCESSIBLE SPACES PROVIDED
VAN SPACES WITH
TOTAL # OF
PARKING SPACES
ACCESSIBLE PARKING
USE WATERCLOSETS
MALE FEMALE
URINALS
ACCESSIBLEREGULAR
DRINKING FOUNTAINSSHOWERS/
TUBS
PLUMBING FIXTURE REQUIREMENTS
PILE SIZE, TYPE AND CAPACITY
PRESUMPTIVE BEARING CAPACITY
SOIL BEARING CAPACITIES:
LATERAL DESIGN CONTROL:
FIELD TEST (PROVIDE COPY OF TEST REPORT)
ARCHITECTURAL, MECHANICAL, COMPONENTS ANCHORED?
PSF
PSF
SEISMIC BASE SHEAR: Vx= Vy=
SITE CLASSIFICATION (TABLE 1613.2)
SPECTRAL RESPONSE ACCELERATION
SEISMIC DESIGN CATEGORY
S %g S %g
WIND BASE SHEARS (FOR MWFRS) Vx= Vy=
EXPOSURE CATEGORY
BASIC WIND SPEED MPH (ASCE-7-98)
FLOOR
MEZZANINE
ROOF
SEISMIC
SNOW
WIND
PSF
PSF
PSF
PSF
IMPORTANCE FACTORS:
GROUND SNOW LOAD:
LIVE LOADS:
WIND LOAD:
DESIGN LOADS:
PANIC HARDWARE:
SMOKE DETECTION SYSTEMS:
FIRE ALARM:
EXIT SIGNS:
EMERGENCY LIGHTING: NO
NO
NO
NO YES
YES
YES
YES
YES
LIFE SAFETY SYSTEM REQUIREMENTS:
LIST EQUIPMENT EFFICIENCIES:
SIZE CATEGORY. IF OVERSIZED, STATE REASON.
CHILLER
SIZE CATEGORY. IF OVERSIZED, STATE REASON.
BOILER
SIZE CATEGORY OF UNIT
COOLING EFFICIENCY
HEATING EFFICIENCY
DESCRIPTION OF UNIT
UNITARY
MECHANICAL SPACING CONDITIONING SYSTEM
BUILDING COOLING LOAD
BUILDING HEATING LOAD
RELATIVE HUMIDITY
SUMMER DRY BULB
WINTER DRY BULB
INTERIOR DESIGN CONDITIONS
SUMMER DRY BULB
WINTER DRY BULB
THERMAL ZONE
MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT
TOTAL EXTERIOR WATTAGE SPECIFIED VS ALLOWED
TOTAL INTERIOR WATTAGE SPECIFIED VS ALLOWED (WHOLE BUILDING OR SPACE BY SPACE)
TOTAL WATTAGE PER FIXTURE
NUMBER OF BALLASTS IN FIXTURE
BALLAST TYPE USED IN THE FIXTURE
NUMBER OF LAMPS IN FIXTURE
LAMP TYPE REQUIRED IN FIXTURE
LIGHTING SCHEDULE
METHOD OF COMPLIANCE:
ELECTRICAL SYSTEM AND EQUIPMENT
SLAB HEATED
HORIZONTAL/VERTICAL REQUIREMENT
R-VALUE OF INSULATION
U-VALUE OF TOTAL ASSEMBLY
DESCRIPTION OF ASSEMBLY
FLOORS SLAB ON GRADE (EACH ASSEMBLY)
R-VALUE OF INSULATION
U-VALUE OF TOTAL ASSEMBLY
DESCRIPTION OF ASSEMBLY
FLOORS OVER UNCONDITIONED SPACE (EACH ASSEMBLY)
U-VALUE OF TOTAL ASSEMBLY
R-VALUE OF INSULATION
DESCRIPTION OF ASSEMBLY
WALLS BELOW GRADE (EACH ASSEMBLY)
DOOR R-VALUES
PROJECTION FACTOR
SOLAR HEAT GAIN COEIFFICIENT
U-VALUE OF ASSEMBLY
OPENINGS (WINDOWS OR DOORS WITH GLAZING)
R-VALUE OF INSULATION
U-VALUE OF TOTAL ASSEMBLY
DESCRIPTION OF ASSEMBLY
EXTERIOR WALLS (EACH ASSEMBLY)
TOTAL SQUARE FOOTAGE OF SKYLIGHTS
U-VALUE OF SKYLIGHT
SKYLIGHTS IN EACH ASSEMBLY
R-VALUE OF INSULATION
U-VALUE OF TOTAL ASSEMBLY
DESCRIPTION OF ASSEMBLY
ROOF/CEILING ASSEMBLY (EACH ASSEMBLY)
ENERGY REQUIREMENTS:
ENERGY SUMMARY
NO
STATE EMPLOYEE'S CREDIT UNION
923 SEASIDE RD SW - OCEAN ISLE BEACH, NC 28469
BUSINESS
MARK ACURI
BRUNSWICK
- EXISTING BUILDING
NEW (SQ. FT.) SUB-TOTAL
.
.
.
..
.
.
.
.
.
. .
STRUCTURAL DESIGN
ELECTRICAL SUMMARY
MECHANICAL SUMMARY
.
910.397.2929 - EXT: 120
..
.
.
.
.
.
.
CBHF Engineers, PLLC
CTT Consulting Engineers
Becker Morgan Group, Inc
.
0 2,713
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
BUILDING CODE SUMMARY
.
.
marcuri@cttengineering.com
.
.
.
.
.
eolds@beckermorgan.com
EMAIL ADDRESS
ADDITION
EXISTING: REPAIR
CONSTRUCTED. BUSINESS
ORIGINAL USE(S) (Ch. 3)
PARTIAL
FLOOD HAZARD AREA: NO YES
403 404 405 406 407 408 409SPECIAL USES: 402 410 411 412
413 414 415 416 417 418 419 420 421
INCIDENTAL USE SEPARATION (508.2.5)
THIS SEPARATION IS NOT EXEMPT AS A NON-SEPARATED USE (SEE EXCEPTIONS)
STATE
RENOVATION
RENOVATED. N/A
CURRENT USE(S) (Ch. 3)
BUSINESSPROPOSED USE(S) (Ch. 3)
(Check all that apply)
III-A
III-B
IV V-A
V-B
EDUCATIONAL
PARKING GARAGE OPEN ENCLOSED REPAIR GARAGE
H-1 DETONATE
I-1
H-2 DEFLAGRATE
I-2
A-1 A-2
I-3
H-3 COMBUST
A-3
I-4
H-4 HEALTH
F-1 MODERATE F-2 LOW
H-5 HPM
A-4 A-5
I-31 2 3 4 5
R-1
S-1 MODERATE S-2 LOW
R-2 R-3 R-4
UTILITY AND MISCELLANEOUS
STORAGE
MERCANTILE
INSTITUTIONAL
HAZARDOUS
BUSINESS
ASSEMBLY
RESIDENTIAL
USE CONDITION
FACTORY
HIGH-PILED
ACCESSORY OCCUPANCIES:
EDUCATIONAL
PARKING GARAGE OPEN ENCLOSED REPAIR GARAGE
INCIDENTAL USES (Table 508.2.5):
FURNACE ROOM WHERE ANY PIECE OF EQUIPMENT IS OVER 400,000 BTU PER HOUR INPUT
ROOMS WITH BOILERS WHERE THE LARGEST PIECE OF EQUIPMENT IS OVER 15 PSI AND 10 HORSEPOWER
REFRIGERANT MACHINE ROOM
HYDROGEN CUTOFF ROOMS, NOT CLASSIFIED AS GROUP H
INCINERATOR ROOMS
PAINT SHOPS, NOT CLASSIFIED AS GROUP H, LOCATED IN OCCUPANCIES OTHER THAN GROUP F
LABORATORIES AND VOCATIONAL SHOPS, NOT CLASSIFIED AS GROUP H, LOCATED IN A GROUP E OR I-2
LAUNDRY ROOMS OVER 100 SQUARE FEET
GROUP I-3 CELLS EQUIPPED WITH PADDED SURFACES
GROUP I-2 WASTE AND LINEN COLLECTION ROOMS
WASTE AND LINEN COLLECTION ROOMS OVER 100 SQUARE FEET
STATIONARY STORAGE BATTERY SYSTEMS HAVING A LIQUID ELECTROLYTE CAPACITY OF MORE THAN 50
GALLONS, OR A LITHIUM-ION CAPACITY OF 1,000 POUNDS USED FOR FACILITY STANDBY POWER,
ROOMS CONTAINING FIRE PUMPS
GROUP I-2 STORAGE ROOMS OVER 100 SQUARE FEET
EMERGENCY POWER OR UNINTERRUPTED POWER SUPPLIES
GROUP I-2 COMMERCIAL KITCHENS
GROUP I-2 LAUNDRIES EQUAL TO OR LESS THAN 100 SQUARE FEET
GROUP I-2 ROOMS OR SPACES THAN CONTAIN FUEL-FIRED HEATING EQUIPMENT
422 423
424 425 426 427
509.9
MARK T. ARCURI
. . . .
. .
INCIDENTAL USE SEPARATION
PARTIAL
LIFE SAFETY PLAN REQUIREMENTS:
FIRE AND/OR SMOKE RATED WALL LOCATIONS (CHAPTER 7)
ASSUMED AND REAL PROPERTY LINE LOCATIONS
EXTERIOR WALL OPENING AREA WITH RESPECT TO DISTANCE TO ASSUMED PROPERTY LINES (705.8)
EXISTING STRUCTURES WITHIN 30 FEET OF THE PROPOSED BUILDING
OCCUPANCY TYPES FOR EACH AREA AS IT RELATES TO OCCUPANT LOAD CALCULATION (TABLE 1004.1.1)
OCCUPANT LOADS FOR EACH AREA
EXIT ACCESS TRAVEL DISTANCES (1016)
COMMON PATH OF TRAVEL DISTANCES (1014.3 & 1028.8)
DEAD END LENGTHS (1018.4)
CLEAR EXIT WIDTHS FOR EACH EXIT DOOR
MAXIMUM CALCULATED OCCUPANT LOAD CAPACITY EACH EXIT DOOR CAN ACCOMMODATE BASED ON
ACTUAL OCCUPANT LOAD FOR EACH EXIT DOOR
A SEPARATE SCHEMATIC PLAN INDICATING WHERE FIRE RATED FLOOR/CEILING AND/OR ROOF STRUCTURE
EGRESS WIDTH (1005.1)
LOCATION OF DOORS WITH PANIC HARDWARE (1008.1.10)
IS PROVIDED FOR PURPOSES OF OCCUPANCY SEPARATION
LOCATION OF DOORS WITH DELAYED EGRESS LOCKS AND THE AMOUNT OF DELAY (1008.1.9.7)
LOCATION OF DOORS WITH ELECTROMAGNETIC EGRESS LOCKS (1008.1.9.8)
LOCATION OF DOORS EQUIPPED WITH HOLD-OPEN DEVICES
LOCATION OF EMERGENCY ESCAPE WINDOWS (1029)
THE SQUARE FOOTAGE OF EACH FIRE AREA (902)
THE SQUARE FOOTAGE OF EACH SMOKE COMPARTMENT (407.4)
NOTE ANY CODE EXCEPTIONS OR TABLE NOTES THAT MAY HAVE BEEN UTILIZED REGARDING THE ITEMS
ABOVE
ACCESSIBLE DWELLING UNITS (SECTION 1107)
.
UNITS
ACCESSIBLETOTAL
UNITS
REQUIRED
UNITS
ACCESSIBLE
PROVIDED
UNITS
TYPE A
REQUIRED
UNITS
TYPE A
PROVIDED
UNITS
TYPE B
REQUIRED
UNITS
TYPE B
PROVIDED
ACCESSIBLE UNITS
TOTAL
PROVIDED
. . . . . . .
(SECTION 1106)
LOT OR
PARKING AREA
REGULAR WITH
5' ACCESS
AISLE
132" ACCESS
AISLE
8' ACCESS
AISLE
.
.
.
A B C D
PROVIDE THE FOLLOWING SEISMIC DESIGN PARAMETERS:
OCCUPANCY CATEGORY (TABLE 1604.5) I II III IV
s 1
A B C D E F
DATA SOURCE: FIELD TEST PRESUMPTIVE HISTORICAL DATA
BASIC STRUCTURAL SYSTEM (CHECK ONE)
BEARING WALL
BUILDING FRAME
MOMENT FRAME
DUAL W/ SPECIAL MOMENT FRAME
DUAL W/ INTERMEDIATE R/C OR SPECIAL STEEL
INVERTED PENDULUM
ANALYSIS PROCEDURE: SIMPLIFIED EQUIVALENT LATERAL FORCE DYNAMIC
YES NO
EARTHQUAKE WIND
SPECIAL INSPECTIONS REQUIRED: YES NO
(SECTION 1106)
SPACE
.
.
.
.
.
.
LAVATORIES
MALE FEMALE
.
.
.
SPECIAL APPROVALS
SPECIAL APPROVAL: (LOCAL JURISDICTION, DEPARTMENT OF INSURANCE, SBCCI, ICC, ETC., DESCRIBE BELOW)
.
THE FOLLOWING DATA SHALL BE CONSIDERED MINIMUM AND ANY SPECIAL ATTRIBUTE REQUIRED TO MEET THE
ENERGY CODE SHALL ALSO BE PROVIDED. EACH DESIGNER SHALL FURNISH THE REQUIRED PORTIONS OF THE
PROJECT INFORMATION FOR THE PLAN DATA SHEET. IF PERFORMANCE METHOD, STATE THE ANNUAL ENERGY
COST FOR THE STANDARD REFERENCE DESIGN VS ANNUAL ENERGY COST FOR THE PROPOSED DESIGN.
CLIMATE ZONE: 3 4 5
METHOD OF COMPLIANCE:
PRESCRIPTIVE
PERFORMANCE
PRESCRIPTIVE
PERFORMANCE
(ENERGY CODE)
(ENERGY CODE)
(ASHRAE 90.1)
(ASHRAE 90.1)
THERMAL ENVELOPE
EXCEED 1
.
OCCUPANCIES
.
.
ENERGY CODE:
ASHRAE 90.1:
PRESCRIPTIVE PERFORMANCE
PRESCRIPTIVE PERFORMANCE
ADDITIONAL PRESCRIPTIVE COMPLIANCE
506.2.1
506.2.2
506.2.3
506.2.4
506.2.5
506.2.6
MORE EFFICIENT MECHANICAL EQUIPMENT
REDUCED LIGHTING POWER DENSITY
ENERGY RECOVERY VENTILATION SYSTEMS
HIGHER EFFICIENCY SERVICE WATER HEATING
ON-SITE SUPPLY OF RENEWABLE ENERGY
AUTOMATIC DAYLIGHTING CONTROL SYSTEMS
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
35250Jason Famiglietti
910.791.4000
jfam@cbhfengineers.com
2,713 0 2,713
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0
N/A
N/A
0
N/A
N/A - EXISTING BUILDING
N/A - EXISTING BUILDING
G002
BUILDING CODE
SUMMARY
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
BE
CK
ER
MO
RG
AN
GR
OU
P, I
NC
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
E
AL
P
RA
C
NN
IH
TU
NI
CT
G
ER
91
0.3
41
.7
60
0
Wilm
in
gto
n, N
C
32
05
R
an
da
ll P
kw
y, S
uite
2
11
Wilm
in
gto
n, N
C 2
84
03
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
W
I
L
M
I
N
G T
O
N
,
N
C
BE
C
K
E
R
M
O
R
G
AN
G
R
O
U
P
,
I
N
C
.
R
e
g
is
te
r
e
d
A
r
c
h
i
tec
u
r
a
l
C
o
r
p
o
ra
ti
o
n
N
o
r
t
h
Ca
r
o
l
i
n
a
Reviewed For Code Compliance
Reviewed For Code Compliance
FE
FE
14
320
68"
BUSINESS OCCUPANCY:
2,713 SF / 100 = 28 OCCUPANTS
14
320
68"
51' TRAVEL DISTANCE
200' MAX ALLOWABLE
TRAVEL DISTANCE
FE
2A FIRE EXTINGUISHER LOCATION
MAXIMUM EGRESS DISTANCE PATH OF TRAVEL
EXIT OR EXIT ACCESS LOCATION
LIFE SAFETY LEGEND
000
000
00.00"
OCCUPANT LOAD CAPACITY
OCCUPANT LOAD
CLEAR EXIT WIDTH
5'-0
" M
AX
.
EXIT
EXIT
NOTE: SIGNAGE TO COMPLY WITH ICC A117.1-2009 SECTION 703.3.11, 703.3.12.
BRAILLE TO COMPLY WITH ICC A1171.1-2009 SECTION 703.4
EXIT SIGNAGE LOCATIONS SHOWN ON PLAN AS ( * )
FINAL LOCATION OF SIGNS TO BE CONFIRMED BY THE AUTHORITY HAVING JURISDICTION
EXIT
EXIT
C
L
9"
6"
9" MIN.
2"
1'-6"
18"x18" CLEAR SPACE
CENTERED ON BRAILLE
LS101
LIFE SAFETY
PLAN
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
BE
CK
ER
MO
RG
AN
GR
OU
P, I
NC
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
E
AL
P
RA
C
NN
IH
TU
NI
CT
G
ER
91
0.3
41
.7
60
0
Wilm
in
gto
n, N
C
32
05
R
an
da
ll P
kw
y, S
uite
2
11
Wilm
in
gto
n, N
C 2
84
03
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
W
I
L
M
I
N
G T
O
N
,
N
C
BE
C
K
E
R
M
O
R
G
AN
G
R
O
U
P
,
I
N
C
.
R
e
g
is
te
r
e
d
A
r
c
h
i
tec
u
r
a
l
C
o
r
p
o
ra
t
i
o
n
N
o
r
t
h
Ca
ro
l
i
n
a
Reviewed For Code Compliance
Reviewed For Code Compliance
Roof Line Above
1
2
3
1 4
4
5
5
6
7
7
8
8
9
9
10
11
12
13
14
15
16
17
18
18
18
18
18
18
18
18
18
18
18
18
18
18 18
19
19
1919
19
19
19
19
19
19
19
19
19
19
20
20
20
20
21
22
23
THRE
SHOL
DTH
RESH
OLD
THRESHOLD
24
CARPET TILECARPET
VCT
CARPET CARPET
TILE
TILE
TILE
VCT
VCT
VCT
VCT
11
12
13
13
13
1
1
19
13
13
CONCRETE
CONCRETE
13
13
Roof Line Above
25
LADDER TOATTIC 15
11
17
11
17
11
16
16
ATM
TELL
ERVA
CUUM
TELL
ERVA
CUUM
15 15 15
26
17
11
17
11
17
11
12
12 12
12 12
12
12
12
1717
27
FLOORING NOTES:
1. REMOVE AND REPLACE ALL
EXISTING CARPET w/ NEW 2x2
CARPET TILES
2. REPLACE ALL VCT FLOORING
IN BATHROOM AND BREAK
ROOM AREAS
CEILING / ROOF NOTES:
1. REMOVE AND REPLACE ALL STAINED
2x2 ACT CEILING TILES THROUGHOUT
2. REPAIR EXISTING CEILING GRID IN
OFFICE 103
3. ADD ICE GUARDS TO ALL STANDING
SEAM METAL ROOFS. OWNER TO
PROVIDE EXACT SPECIFICATION
KEYNOTE LEGEND:
- INSTALL NEW TRIM AROUND DOOR
AND SIDELITES. NEW TRIM TO
MATCH EXISTING INTERIOR DOOR
TRIM
- REVERSE SWING OF EXISTING
DOOR AND INSTALL DOOR CLOSER
- REPAIR ALL DRYWALL CRACKS,
HOLES AND PREVIOUS ELECTRICAL
BOXES IN ALL ROOMS
- INSTALL NEW LOCK HARDWARE ON
INTERIOR DOUBLE DOORS @
VESTIBULES. IF LOCK HARDWARE
IS UNABLE TO BE INSTALLED;
REPLACE DOORS
- REPLACE EXISTING SOLID DOORS
@ EACH END OFFICE. NEW DOOR
TO HAVE GLAZING IN UPPER HALF
1
2
3
4
5
- INSTALL PEEP HOLE IN
EXISTING DOOR
- REMOVE EXISTING DOOR TO
BATHROOM AND FRAME IN.
CREATE NEW DOOR OPENING
ON ADJACENT WALL. RE-USE
DOOR IF POSSIBLE.
- REPLACE EXISTING TOILET
FIXTURES IN EACH
BATHROOM
- ADD BLOCKING AND INSTALL
18" VERTICAL GRAB BARS IN
EACH BATHROOM LOCATION
- REPLACE CRACKED AND
BOWED UPPER SOFFIT TRIM
6
7
8
9
10
- PAINT ALL EXISTING
COLUMNS; REFER TO SPECS
- PATCH BASES AND TOPS OF
ALL COLUMNS
- REMOVE AND REPLACE ALL
EXPANSION JOINT MATERIAL
w/ SEALANT; FILL ANY EMPTY
JOINTS w/ SEALANT
- REPLACE SEALANT ON
MASONRY WALLS AND FILL
ALL GAPS
- REMOVE FIBER EXPANSION
MATERIAL AND REPLACE
SEALANT AT CONCRETE
ISLAND JOINTS THROUGHOUT
11
12
13
14
15
- ADD PLASTIC YELLOW
SLEEVES OVER EXISTING 4"
DIA. BOLLARDS THROUGHOUT
- REPLACE ALL CAULK WHERE
BASES OF COLUMNS MEET
CONCRETE THROUGHOUT.
PATCH BASES AND TOPS OF
ALL COLUMNS IN DRIVE-THRU
AREA
- EXTERIOR WINDOWS: CAULK
ALL TRIM AND LINTELS.
- LINTELS: SAND, TREAT RUST
AND PRIME ALL LINTELS
- INSTALL AUTOMATIC DOOR
OPENERS @ EACH VESTIBULE
(BOTH INTERIOR AND
EXTERIOR DOORS) INSTALL
ADA PUSH BUTTONS AS REQ'D
16
17
18
19
20
- NEW BUILT-IN COUNTERTOP TO
MATCH DESIGN OF
COUNTERTOP IN S.D.B. AREA
- INSTALL NEW BASE TRIM ON
INTERIOR WALL OF VAULT; TRIM
TO MATCH EXISTING
- INSTALL NEW 5' HIGH
PARTITION. SWINGING DOOR TO
MATCH DOOR @ TELLER
LOCATIONS
- REPAIR FLOORING AT NEW
DOOR OPENING CONSTRUCTION
- PRESSURE WASH EXTERIOR;
REMOVE EFFLORESENCE
- FRONT GABLE: FILL EXISTING
MOUNTING HOLES AND PAINT /
RECOAT THE STUCCO
- PAINT WALL ACCENT COLOR;
REFER TO SPECS
21
22
23
24
25
GENERAL NOTES:
1. SEE DRAWINGS BY OTHERS FOR
PLUMBING, MECHANICAL,
ELECTRICAL AND SITE WORK
2. ALL FURNITURE, BANKING
EQUIPMENT AND SECURITY
SYSTEM ARE THE
RESPONSIBILITY OF OWNER
3. PAINT INTERIOR AND EXTERIOR
PER SPECIFICATIONS
26
27
A101
FLOOR PLAN
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
BE
CK
ER
MO
RG
AN
GR
OU
P, I
NC
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
E
AL
P
RA
C
NN
IH
TU
NI
CT
G
ER
91
0.3
41
.7
60
0
Wilm
in
gto
n, N
C
32
05
R
an
da
ll P
kw
y, S
uite
2
11
Wilm
in
gto
n, N
C 2
84
03
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
W
I
L
M
I
N
G T
O
N
,
N
C
BE
C
K
E
R
M
O
R
G
AN
G
R
O
U
P
,
I
N
C
.
R
e
g
is
te
r
e
d
A
r
c
h
i
tec
u
r
a
l
C
o
r
p
o
ra
ti
o
n
N
o
r
t
h
Ca
r
o
l
i
n
a
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
SPAN
NEW DOOR OPNG
NOTE:
SHORE ROOF SYSTEM ON EACH SIDE UNTIL HEADER HAS BEEN INSTALLED.
JACK STUDS (2) STUDS TOMATCH EXIST WIDTH @ EA
SIDE (MIN)
WALLOPENING
HEADER
KING STUDS(2) FULL HEIGHTSTUDS TO MATCHEXIST WIDTH @ EASIDE (MIN)
JACK STUDS
(2) 2x8
DISCONTINUEDWALL STUD
SIZE
2 (MIN)
REMARKS
LOAD BEARING WOOD HEADER SCHEDULE
SEE NOTE
1.
DETAIL:
NEW OPNG IN EXIST LOADBEARING WOOD WALL. SEELINTEL SCHEDULE ON THIS
SHEET. TEMP SHORE ROOFTRUSSES PRIOR TO INSTALL.
NEW 2X WOOD WALL INFILL. MATCH EXIST WIDTHAND SPACE NEW VERT STUDS AT 16" OC
AREA OF STRUCTURAL RENOVATION
Firm
Lic
ense
Num
ber: F
-01
13
ww
w/c
tt@
ctte
ngin
eering.c
om
91
0.3
97
.29
71
Fax
91
0.3
97
.29
29
P
h.
Wilm
ingto
n, N
C 2
84
03
38
09
Peach
tree A
ve.,
Suite 1
02
CO
NS
ULT
ING
EN
GIN
EER
SC
RIS
ER
TR
OU
TMA
N T
AN
NER
ST
AT
E E
MP
LO
YE
ES
’ C
RE
DIT
UN
ION
..
.
.
.
.
.
.
.
OC
EA
N IS
LE
BE
AC
H B
RA
NC
H
OCEAN ISLE BEACH, NC 28469
ST
AT
E E
MP
LO
YE
ES
’ C
RE
DIT
UN
ION
923 SEASIDE ROAD SW
.
.
.
.
RALEIGH, NC 27611
PO BOX 27655
DESIGNED BY:
DRAWN BY:
SCALE:
DATE:
FILE NUMBER:
QUALITY CONTROL:
OWNER:
ADDRESS:
ADDRESS:
PROJECT:
SEAL
NO
REVISIONS
DATE
SHEET NUMBER:
DESC:
3/16/17
RLP
RLP
RLP
NTS
7482
MARCH 17, 2017
S1
STRUCTURALRENOVATION PLAN
GENERAL
A. ALL DESIGN AND CONSTRUCTION IS BASED ON AND SHALL BE IN ACCORDANCE WITH THE NORTH CAROLINA BUILDING CODE, 2012 EDITION. ALLREFERENCED STANDARDS SHALL BE OF THE EFFECTIVE DATE NOTED IN THE CONTROLLING BUILDING CODE.
B. NO PROVISION OF ANY REFERENCED STANDARD SPECIFICATION, MANUAL OR CODE (WHETHER OR NOT SPECIFICALLY INCORPORATED BY REFERENCE INTHE CONSTRUCTION DOCUMENTS) SHALL BE EFFECTIVE TO CHANGE THE DUTIES AND RESPONSIBILITIES OF OWNER, CONTRACTOR, ENGINEER, SUPPLIER,OR ANY OF THEIR CONSULTANTS, AGENTS, OR EMPLOYEES FROM THOSE SET FORTH IN THE CONSTRUCTION DOCUMENTS. NOR SHALL IT BE EFFECTIVE TOASSIGN TO THE STRUCTURAL ENGINEER OF RECORD OR ANY OF THE STRUCTURAL ENGINEER OF RECORD'S CONSULTANTS, AGENTS, OR EMPLOYEES ANYDUTY OR AUTHORITY TO SUPERVISE OR DIRECT THE FURNISHING OR PERFORMANCE OF THE WORK OR ANY DUTY OR AUTHORITY TO UNDERTAKERESPONSIBILITIES CONTRARY TO THE PROVISIONS OF THE CONSTRUCTION DOCUMENTS.
C. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS AND NOTIFY ARCHITECT/STRUCTURAL ENGINEER OF RECORD OF ANYDISCREPANCIES PRIOR TO PROCEEDING WITH WORK. FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS, SEE ARCHITECTURAL DRAWINGS.
D. DO NOT SCALE FOR DIMENSIONS NOT SHOWN ON DRAWINGS. SEND WRITTEN REQUEST FOR INFORMATION TO THE ARCHITECT FOR DIMENSIONS NOTPROVIDED.
E. THE STRUCTURE SHOWN ON THESE DRAWINGS IS SELF-SUPPORTING ONLY IN ITS COMPLETED FORM. THE GENERAL CONTRACTOR SHALL BERESPONSIBLE FOR PROVIDING THE DESIGN, ADEQUACY, SAFETY, AND STABILITY OF TEMPORARY ERECTION BRACING AND SHORING.
F. NO PROVISIONS HAVE BEEN MADE IN THE DESIGN FOR THE SUPPORT OF A CONCENTRATED LOAD FROM PLUMBING, MECHANICAL OR HVAC EXCEPT ASSHOWN ON THE DRAWINGS.
G. THE GENERAL CONTRACTOR SHALL COORDINATE ALL SIZES AND LOCATIONS OF FLOOR, ROOF, AND WALL PENETRATIONS WITH MECHANICAL ANDARCHITECTURAL DRAWINGS. ALL PENETRATIONS NOT SHOWN ON STRUCTURAL DRAWINGS MUST BE APPROVED BY THE STRUCTURAL ENGINEER OFRECORD UNLESS NOTED OTHERWISE.
EXISTING CONDITIONS
A. THE GENERAL CONTRACTOR SHALL SURVEY THE EXISTING STRUCTURE TO DETERMINE THAT ALL MODIFICATIONS AS INDICATED IN THE CONSTRUCTIONDOCUMENTS ARE FEASIBLE AND PRACTICAL AND SHALL REPORT ANY DISCREPANCIES OR UNUSUAL CONDITIONS TO THE ARCHITECT/STRUCTURALENGINEER OF RECORD. FIELD DIMENSION NEW STRUCTURAL ELEMENTS PRIOR TO THE SUBMISSION OF SHOP DRAWINGS.
B. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION THAT MIGHT BE AFFECTEDBY OR OTHERWISE INTERFERE WITH INSTALLATION OF NEW WORK. THIS INCLUDES THOSE THAT MIGHT BE DAMAGED BY NEW FOUNDATION OR OTHERWORK, AND THOSE WHOSE PRESENCE MIGHT LEAD TO DAMAGE TO THE NEW WORK (SUCH AS DIFFERENTIAL SETTLEMENT, ETC.).
DESIGN LOADS
A. DESIGN ROOF DEAD LOAD:
1. 40 PSF
B. DESIGN ROOF LIVE LOAD:
1. 20 PSF
WOOD FRAMING
A. CONFORM TO NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, PUBLISHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION, AF & PA NDSAND AF & PA SPECIAL DESIGN PROVISIONS FOR WIND & SEISMC.
B. UNLESS NOTED OTHERWISE, USE SPRUCE-PINE-FIR , 19% MAX. MOISTURE CONTENT, AS FOLLOWS:
1. BEAMS, HEADERS NO. 1/NO. 2
2. LOAD BEARING STUDS, & EXTERIOR STUDS NO. 1/NO. 2
3. JOISTS, PURLINS NO. 1/NO. 2
4. SUB-PURLINS, PLATES, BLOCKING NO. 1/NO. 2
5. NON-LOAD BEARING INTERIOR STUDS STUD GRADE
C. METAL CONNECTORS SHALL BE FASTENED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS TO DEVELOP THE MAXIMUM PUBLISHED CAPACITY.
D. TIMBER FASTENING SHALL BE PER GOVERNING BUILDING CODE "MINIMUM FASTENING SCHEDULE" UNLESS NOTED AS GREATER ON CONSTRUCTIONDRAWINGS. CONNECTORS TO BE SIMPSON OR APPROVED ALTERNATE, WITH MINIMUM CAPACITY AS NOTED.
E. TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES TO THE PIECE AND BE STARTED AT 1/3 THE NAIL LENGTH FROM THE END OF THE PIECE.
F. ALL NAILS SHALL BE COMMON WIRE NAILS.
G. GENERAL STRUCTURAL WOOD NOTES:
1. (3)-2x, (2)-2x AND (2)-2x + 1/2" PLYWOOD PLATE BEAMS SHALL BE SPIKED TOGETHER W/12d NAILS @ 12" O.C. TOP & BOTTOM. (4)-2x AND LARGER BEAMSSHALL BE BOLTED TOGETHER W/ 1/2" DIAMETER BOLTS @ 2'-6" O.C. MAX. TOP & BOTTOM.
3. MULTIPLE STUD OR SOLID COLUMNS SHALL BE CONTINUOUS FROM FRAMING LEVEL, WHERE SHOWN, TO THE FOUNDATION. THIS WILL REQUIRE SOLIDBLOCKING WITHIN THE FLOOR FRAMING EQUAL TO THE COLUMN DIMENSION (SEE TYPICAL DETAIL).
4. MULTIPLE STUD PACK COLUMNS SHALL BE CONNECTED LATERALLY TO ONE ANOTHER WITH 16d NAILS AT 16" O.C. VERTICALLY.
H. PROVIDE MISCELLANEOUS LUMBER INDICATED AND LUMBER FOR SUPPORT OR ATTACHMENT OF OTHER CONSTRUCTION, INCLUDING BLOCKING ANDNAILERS.
I. PROVIDE FASTENERS AS FOLLOWS:
1. NAILS, BRADS, AND STAPLES: ASTM F 1667
2. POWER-DRIVEN FASTENERS: NES NER-272
3. WOOD SCREWS: ASME B18.6.1
J. INSTALLATION, GENERAL: SET ROUGH CARPENTRY TO REQUIRED LEVELS AND LINES, WITH MEMBERS PLUMB, TRUE TO LINE, CUT, AND FITTED. FIT ROUGHCARPENTRY TO OTHER CONSTRUCTION; SCRIBE AND COPE AS NEEDED FOR ACCURATE FIT. LOCATE NAILERS, BLOCKING, AND SIMILAR SUPPORTS TOCOMPLY WITH REQUIREMENTS FOR ATTACHING OTHER CONSTRUCTION. COMPLY WITH AF&PA'S "DETAILS FOR CONVENTIONAL WOOD FRAMECONSTRUCTION," UNLESS OTHERWISE INDICATED. INSTALL ENGINEERED WOOD PRODUCTS TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.INSTALL METAL FRAMING ANCHORS TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. DO NOT SPLICE STRUCTURAL MEMBERS BETWEENSUPPORTS, UNLESS OTHERWISE INDICATED. PROVIDE BLOCKING AND FRAMING AS INDICATED IN CONSTRUCTION DRAWINGS AND AS REQUIRED TOSUPPORT FACING MATERIALS, FIXTURES, SPECIALTY ITEMS, AND TRIM. SORT AND SELECT LUMBER SO THAT NATURAL CHARACTERISTICS WILL NOTINTERFERE WITH INSTALLATION OR WITH FASTENING OTHER MATERIALS TO LUMBER. DO NOT USE MATERIALS WITH DEFECTS THAT INTERFERE WITHFUNCTION OF MEMBER OR PIECES THAT ARE TOO SMALL TO USE WITH MINIMUM NUMBER OF JOINTS OR OPTIMUM JOINT ARRANGEMENT. COMPLY WITHAWPA M4 FOR APPLYING FIELD TREATMENT TO CUT SURFACES OF PRESERVATIVE-TREATED LUMBER. SECURELY ATTACH ROUGH CARPENTRY WORK TOSUBSTRATE BY ANCHORING AND FASTENING AS INDICATED IN CONSTRUCTION DRAWINGS, COMPLYING WITH NES NER-272 FOR POWER-DRIVEN FASTENERSAND THE GOVERNING MODEL CODE WITH RELEVANT ADDENDA, REFERENCED IN CONSTRUCTION DRAWINGS, AND ALL RELATED AND REFERENCEDSTANDARDS. SELECT FASTENERS OF SIZE THAT WILL NOT FULLY PENETRATE MEMBERS WHERE OPPOSITE SIDE WILL BE EXPOSED TO VIEW OR WILLRECEIVE FINISH MATERIALS. MAKE TIGHT CONNECTIONS BETWEEN MEMBERS. INSTALL FASTENERS WITHOUT SPLITTING WOOD; DO NOT COUNTERSINK NAILHEADS, UNLESS OTHERWISE INDICATED.
K. WOOD BLOCKING, AND NAILER INSTALLATION: INSTALL WHERE INDICATED AND WHERE REQUIRED FOR ATTACHING OTHER WORK. FORM TO SHAPESINDICATED AND CUT AS REQUIRED FOR TRUE LINE AND LEVEL OF ATTACHED WORK. COORDINATE LOCATIONS WITH OTHER WORK INVOLVED. ATTACH ITEMSTO SUBSTRATES TO SUPPORT APPLIED LOADING. RECESS BOLTS AND NUTS FLUSH WITH SURFACES, UNLESS OTHERWISE INDICATED. WHEREWOOD-PRESERVATIVE-TREATED LUMBER IS INSTALLED ADJACENT TO METAL DECKING, INSTALL CONTINUOUS FLEXIBLE FLASHING SEPARATOR BETWEENWOOD AND METAL DECKING.
L. WALL AND PARTITION FRAMING INSTALLATION: PROVIDE SINGLE BOTTOM PLATE AND DOUBLE TOP PLATES USING MEMBERS OF 2-INCH NOMINAL THICKNESSWHOSE WIDTHS EQUAL THAT OF STUDS, EXCEPT SINGLE TOP PLATE MAY BE USED FOR NON-LOAD-BEARING PARTITIONS. FASTEN PLATES TO SUPPORTINGCONSTRUCTION, UNLESS OTHERWISE INDICATED, AS FOLLOWS: OVERLAP DOUBLE TOP PLATE MINIMUM OF 6” AT CORNERS AND INTERSECTIONS ANDTOENAIL STUDS TO BOTTOM PLATE AND END-NAIL TO LOWER TOP PLATE. PROVIDE STUDS IN CONTINUOUS LENGTHS WITHOUT SPLICES. PROVIDECONTINUOUS HORIZONTAL BLOCKING AT MIDHEIGHT OF PARTITIONS MORE THAN 96 INCHES HIGH, USING MEMBERS OF 2-INCH NOMINAL THICKNESS AND OFSAME WIDTH AS WALL OR PARTITIONS, WHERE SHEATHING IS NOT PRESENT IN FINISHED CONSTRUCTION. CONSTRUCT CORNERS AND INTERSECTIONS WITHTHREE OR MORE STUDS, WHERE NOT EXPLICITLY NOTED OR SCHEDULED IN CONSTRUCTION DRAWINGS. FRAME OPENINGS WITH MULTIPLE STUDS ANDHEADERS. PROVIDE NAILED HEADER MEMBERS OF THICKNESS EQUAL TO WIDTH OF STUDS. SUPPORT HEADERS ON JAMB STUDS.
1/8" = 1'-0"1
RENOVATION PLAN
Reviewed For Code Compliance
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266
www.cbhfengineers.com
NC# P-0506c
Copyright 2017 CBHF Engineers, PLLC
Engineers, PLLC
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
E-001
ELECTRICALNOTES, LEGEND
ELECTRICAL LEGEND
3-WAY SWITCH, SINGLE POLE 120/277 VAC, 20A, MOUNTED AT 46" AFF UNLESS OTHERWISE NOTEDS3
RECEPTACLE, DUPLEX, 120VAC, 20A, MOUNTED 30" AFF (SM) INDICATES SURFACE MOUNTED DEVICE WITH SURFACE MOUNTED RACEWAY
EXISTING PANEL BOARD, SURFACE MOUNTED, SIZE and RATINGS AS INDICATED ON PANEL SCHEDULE
CONDUIT, HOME RUN TO PANEL BOARD
SYMBOL DESCRIPTION
HATCHING INDICATES ITEMS TO BE DEMOLISHED. REMOVE DEVICES, EQUIPMENT, FIXTURES INDICATED,CIRCUITS AND CONDUIT BACK TO SOURCE UNLESS OTHERWISE NOTED.
EXISTING 2x4 LIGHT FIXTURE
GENERAL NOTES:1. ALL ELECTRICAL WORK SHALL BE IN FULL COMPLIANCE WITH NFPA 70, THE NORTH CAROLINA STATE BUILDING CODE, ALL
LOCAL CODES AND ORDINANCES AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVINGJURISDICTION.
2. ALL EQUIPMENT PROVIDED BY THE CONTRACTOR SHALL BE LISTED AND LABELED BY A NATIONALLY-RECOGNIZED TESTINGAGENCY, ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, FOR THE CONDITIONS OF INSTALLATION. ALL MATERIAL,EQUIPMENT AND DEVICES SHALL BE NEW CURRENT PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN THEPRODUCTION OF SUCH PRODUCTS. EQUIPMENT SHALL BE SUITABLE FOR ITS APPLICATION (E.G. WHEN INSTALLEDOUTDOORS, IT SHALL BE WEATHERPROOF, ETC.)
3. THE CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR WORK REQUIREMENTS, THEAMOUNT OF SPACE AVAILABLE FOR ELECTRICAL EQUIPMENT, AND LAYOUT HIS WORK IN A COMPATIBLE ANDCOMPLEMENTARY MANNER.
4. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THOROUGHLY FAMILIARIZING HIMSELF WITH ANY CONTRACTUALREQUIREMENTS AS MAY BE SET FORTH IN THE OTHER DIVISIONS OF THE PROJECT SPECIFICATIONS.
5. UNLESS SPECIFICALLY NOTED OTHERWISE, SYSTEMS PROVIDED OR INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BECOMPLETE AND FULLY-FUNCTIONING AFTER INSTALLATION. INCIDENTAL COMPONENTS MAY NOT BE SHOWN, AND ALL WORKWHICH MAY BE REASONABLY IMPLIED AS BEING INCIDENTAL TO THIS WORK, BUT REQUIRED FOR THE PROPER OPERATIONOF THE EQUIPMENT OR SYSTEM, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. ADDITIONAL CIRCUITSSHALL BE INSTALLED WHEREVER NEEDED TO CONFORM TO THE SPECIFIC REQUIREMENTS OF EQUIPMENT.
6. TEMPORARY POWER CONNECTIONS AS REQUIRED SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSETO THE OWNER. ALL TEMPORARY EQUIPMENT WIRING SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE.THE CONTRACTOR SHALL PROVIDE DETAILS, METHODS, MATERIALS, ETC. TO THE ARCHITECT/ENGINEER PRIOR TO MAKINGTEMPORARY CONNECTIONS. FURNISH AND INSTALL ALL EQUIPMENT AND MATERIALS INCLUDING CONTROL EQUIPMENT,MOTOR STARTERS, BRANCH AND FEEDER CIRCUIT BREAKERS, PANELBOARDS, TRANSFORMERS, ETC. FOR TEMPORARYPOWER. COORDINATE WITH THE ELECTRICAL UTILITY COMPANY AS REQUIRED.
7. THE WORK SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING AT THE COMPLETION OF WORK AND ANYMINOR CORRECTIONS, CHANGES OR ADJUSTMENTS NECESSARY FOR THE PROPER FUNCTIONING OF THE SYSTEM ANDEQUIPMENT.
8. ALL ELECTRICAL EQUIPMENT SHALL, AT ALL TIMES DURING CONSTRUCTION, BE ADEQUATELY PROTECTED AGAINSTMECHANICAL INJURY, OR DAMAGE BY WATER AND/OR THE ELEMENTS. ELECTRICAL EQUIPMENT SHALL NOT BE STORED OUTOF DOORS, BUT SHALL BE STORED IN DRY PERMANENT SHELTERS. IF AN APPARATUS HAS BEEN DAMAGED, OR HAS BEENSUBJECT TO POSSIBLE INJURY BY WATER OR THE ELEMENTS, SUCH DAMAGE SHALL BE REPLACED AT NO ADDITIONAL COSTTO THE OWNER.
9. DO NOT SCALE ELECTRICAL DRAWINGS. FIELD VERIFY ALL DIMENSIONS.
10. CIRCUIT LAYOUTS ARE NOT INTENDED TO SHOW THE NUMBER OF FITTINGS, OR OTHER INSTALLATION DETAILS. UNLESSNOTED OTHERWISE, THE EXACT ROUTING OF FEEDER AND BRANCH CIRCUIT RACEWAYS AND CABLES IS THERESPONSIBILITY OF THE CONTRACTOR. RISER AND GENERAL CIRCUIT ARRANGEMENTS ARE SHOWNSCHEMATICALLY/DIAGRAMMATICALLY ONLY. THE CONTRACTOR SHALL ROUTE CONDUITS AS REQUIRED BY THE CONDITIONSOF THE INSTALLATION.
11. UNLESS DIMENSIONED, DEVICE LOCATIONS SHOWN ON THE DRAWINGS ARE APPROXIMATE. ADJUST EXACT LOCATIONS ASREQUIRED TO SERVE THE INTENDED PURPOSE AND TO AVOID CONFLICTS AND INTERFERENCES WITH OTHER TRADES.EXACT DEVICE LOCATIONS SHALL BE AS INDICATED ON THE ARCHITECTURAL DRAWINGS OR AS DIMENSIONED. IF NOTSHOWN ON THE ARCHITECTURAL DRAWINGS OR DIMENSIONED ON THE ELECTRICAL DRAWINGS, VERIFY EXACT LOCATIONWITH THE ARCHITECT/ENGINEER PRIOR TO ROUGH-IN.
12. CONDUIT TERMINATING IN PRESSED STEEL BOXES SHALL HAVE DOUBLE LOCKNUTS AND INSULATED BUSHINGS. CONDUITSTERMINATING IN GASKETED ENCLOSURES SHALL BE TERMINATED WITH GROUNDING TYPE CONDUIT HUBS.
13. THE DRAWINGS INDICATE BRANCH CIRCUIT HOMERUN CONDUCTORS VIA ARROWHEADS. PROVIDE NEUTRAL, EQUIPMENTGROUND CONDUCTORS AS REQUIRED. ADDITIONAL CONDUCTORS REQUIRED FOR CONTROL SHALL BE INCLUDED EVEN IFNOT EXPLICITLY SHOWN.
14. SEAL ALL CONDUIT OPENINGS THROUGH EXTERIOR BUILDING WALLS WATERTIGHT.
15. RACEWAYS PENETRATING FLOORS, CEILINGS OR WALLS SHALL BE PROPERLY SEALED SMOKETIGHT.
16. ALL RACEWAYS SHALL BE CONCEALED WHERE POSSIBLE. IF APPLICABLE, MATCH EXISTING RACEWAY INSTALLATIONMETHODS AND ROUTINGS AT OR NEAR EXISTING FACILITIES.
17. INSTALL EXPOSED RACEWAYS PARALLEL TO OR AT RIGHT ANGLES TO NEARBY SURFACES OR STRUCTURAL MEMBERS, ANDFOLLOW THE SURFACE CONTOURS AS MUCH AS POSSIBLE. NO DIAGONAL RUNS WILL BE ALLOWED. ALL CONDUITS SHALLBE RUN STRAIGHT AND TRUE. RUN PARALLEL OR BANKED RACEWAYS TOGETHER ON COMMON SUPPORTS WHEREPRACTICAL. MAKE BENDS IN PARALLEL OR BANKED RUNS FROM SAME CENTERLINE TO MAKE BENDS PARALLEL.
18. PATCHING OF WATERPROOFED SURFACES SHALL RENDER THE AREA OF THE PATCHING COMPLETELY WATERPROOF.
19. ALL MOTORS AND OTHER VIBRATING EQUIPMENT SHALL BE CONNECTED TO THE CONDUIT SYSTEM BY MEANS OF A SHORTSECTION (18 INCH MINIMUM) OF FLEXIBLE CONDUIT UNLESS OTHERWISE INDICATED. AN EQUIPMENT GROUNDINGCONDUCTOR SHALL BE INSTALLED INSIDE THE FLEXIBLE CONDUIT AND TERMINATE AT THE LOAD END WITH AN APPROVEDGROUNDING CLAMP OR LUG.
20. CEILING MOUNTED DEVICES INSTALLED IN ACOUSTICAL TILE CEILING AREAS SHALL BE SUPPORTED FROM THE STRUCTUREABOVE WITH RODS OF SUFFICIENT SIZE TO PREVENT VERTICAL MOVEMENT OF THE OUTLET BOX. BRIDGES ALONE ARE NOTADEQUATE UNLESS SPECIFICALLY APPROVED. CEILING MOUNTED EXIT LIGHT FIXTURES SHALL BE INSTALLED LEVEL. DONOT SUPPORT DEVICES FROM ACOUSTICAL CEILING TILE.
21. PROVIDE ADHESIVE BACKED RECEPTACLE DEVICE PLATE LABELS IDENTIFYING THE CIRCUIT FEEDING THE DEVICE. LABELSSHALL INDICATE PANEL AND CIRCUIT NUMBER.
22. FINAL TYPED PANELBOARD DIRECTORIES INSTALLED IN THE PANELBOARD DOOR POCKET SHALL INCLUDE FINAL ACTUALROOM NAMES AND NUMBERS IN ADDITION TO THE GENERAL DESCRIPTION SHOWN ON THE PANEL SCHEDULES ON THEDRAWINGS.
23. CONDUCTOR SIZING IS BASED ON 75 DEGREE C. COPPER NEC RATINGS, UNLESS NOTED OTHERWISE. THE CONTRACTORSHALL VERIFY, PRIOR TO INSTALLATION OF CONDUCTORS OR CONDUIT FEEDING ANY EQUIPMENT, THE ELECTRICALEQUIPMENT IS RATED FOR USE WITH 75 DEGREE C. WIRING. IF ANY EQUIPMENT IS RATED FOR USE WITH LESS THAN 75DEGREE C. CONDUCTORS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY FOREVALUATION/CORRECTION.
24. DO NOT PULL CONDUCTORS UNTIL THE CONDUIT SYSTEM IS COMPLETE IN EVERY DETAIL. IN THE CASE OF CONCEALEDWORK, "COMPLETE" MEANS UNTIL ALL ROUGH PLASTERING OR MASONRY HAS BEEN COMPLETED.
25. WHERE SIZE IS NOT SHOWN ON THE DRAWINGS, BRANCH CIRCUITS SHALL CONSIST OF #12 OR #10 AWG MINIMUMPHASE, NEUTRAL AND EQUIPMENT GROUND CONDUCTORS IN 3/4” MINIMUM RACEWAY.
26. USE #10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS WITH A TOTAL INSTALLED LENGTH GREATER THAN75 FEET AND/OR BRANCH CIRCUIT HOMERUNS LONGER THAN 50 FEET, I.E.; #12 AWG INCREASED TO #10 AWG FORRECEPTACLE BRANCH CIRCUITS OVER 75 FEET TOTAL LENGTH (INCLUDING THE HOMERUN SEGMENT) AND HOMERUNS OVER50 FEET.
27. PROVIDE SEPARATE, INDIVIDUAL NEUTRAL CONDUCTORS FOR ALL RECEPTACLE CIRCUITS.
28. KEEP CONDUCTOR SPLICES TO A MINIMUM. INSTALL SPLICES AND TAPES THAT POSSESS EQUIVALENT OR BETTERMECHANICAL STRENGTH AND INSULATION RATINGS THAN CONDUCTORS BEING SPLICED. USE SPLICE AND TAPCONNECTORS COMPATIBLE WITH CONDUCTOR MATERIAL. INSTALL CONDUCTORS AT EACH OUTLET WITH AT LEAST 6 INCHESOF SLACK. CONNECT OUTLETS AND COMPONENTS TO WIRING AND TO GROUND AS INDICATED AND INSTRUCTED BY THEMANUFACTURER.
29. DO NOT SPLICE BRANCH CIRCUIT HOMERUNS WITHOUT THE PERMISSION OF THE ARCHITECT/ENGINEER. HOMERUNS SHALLBE CONTINUOUS FROM THE LAST OUTLET BOX TO THE SERVING PANELBOARD.
30. DO NOT COMBINE BRANCH CIRCUIT HOMERUNS UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
31. DO NOT CHANGE CIRCUITING SHOWN WITHOUT PERMISSION OF THE ARCHITECT/ENGINEER.
32. TROUGH TAPS SHALL BE AT SWITCH AMPACITY, UNLESS NOTED OTHERWISE.
33. INSTALL WIRING DEVICES AT HEIGHTS AS SHOWN ON THE DRAWINGS. ALSO COORDINATE MOUNTING HEIGHTS WITH THEARCHITECTURAL DRAWINGS AND CASEWORK DETAILS. IF CONFLICTING, ARCHITECTURAL DRAWINGS AND DETAILS SHALLGOVERN.
34. IN AREAS IN WHICH DUAL LEVEL SWITCHING IS INDICATED (TYPICALLY BY 2 OR MORE ADJACENT, GANGED SWITCHES),PROVIDE THE APPROPRIATE NUMBER OF CONDUCTORS TO FACILITATE THIS FUNCTION (AS TYPICALLY SHOWN).
35. COORDINATE LIGHTING FIXTURE LOCATIONS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. IF CONFLICTS ARENOTED, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER BEFORE PROCEEDING.
36. ADJACENT SWITCHES SHALL BE GANGED. INSTALL BARRIERS BETWEEN UNLIKE VOLTAGE SECTIONS.
37. WHERE THE DRAWINGS INDICATE A LIGHTING FIXTURE IS TO BE PROVIDED WITH SPECIAL FEATURES/SWITCHING (DIMMING,EMERGENCY BATTERY BALLAST, MULTI-LEVEL, ETC), THE CONTRACTOR SHALL PROVIDE THESE FIXTURES WITH THEAPPROPRIATE BALLASTING TO ACCOMMODATE THE SPECIAL FEATURE. THE CONTRACTOR SHALL PROVIDE THE FIXTURESAS INDICATED IN THE LIGHTING FIXTURE SCHEDULE WITH MODIFICATIONS AS REQUIRED BY DRAWING NOTES.
38. COORDINATE LOCATIONS OF PLUMBING, MECHANICAL, DATA AND TELEPHONE AND AUDIO/VISUAL EQUIPMENT AND OFOWNER-PROVIDED EQUIPMENT WITH THE RESPECTIVE CONTRACTORS AND VENDORS AND THE OWNER BEFORE ROUGH-IN.ADJUST LIGHTING FIXTURES, RECEPTACLES AND ELECTRICAL EQUIPMENT TO ACCOMMODATE THIS EQUIPMENT. ADVISE THEARCHITECT/ENGINEER OF CONFLICTS BEFORE ROUGH-IN.
39. BEFORE COMMENCING WORK OR ORDERING MATERIALS, THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES ANDVERIFY THE NAMEPLATE RATINGS OF ALL EQUIPMENT (MOTORS, HEATERS, COMPRESSORS, ETC.) AND ADJUST THE RATINGSOF THE ELECTRICAL EQUIPMENT (SWITCHES, FUSES, CIRCUIT BREAKERS, FEEDERS, ETC.) AS APPROPRIATE TO SERVE THISEQUIPMENT.
40. ENERGIZE EQUIPMENT ONLY AFTER OBTAINING PERMISSION FROM THE CONTRACTOR PROVIDING THE EQUIPMENT.
41. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR PROVIDING THE EQUIPMENT SHALL MAKE FINALCONNECTIONS TO HIS EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL, PLUMBINGAND GENERAL CONTRACTORS, PRIOR TO ORDERING OR INSTALLATION OF ANY EQUIPMENT, TO VERIFY MECHANICAL,PLUMBING AND GENERAL CONTRACTOR PROVIDED EQUIPMENT REQUIREMENTS ARE PROVIDED IN THE ELECTRICAL DESIGN.IF ELECTRICAL REQUIREMENTS DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR PROVIDING THEEQUIPMENT SHALL BE RESPONSIBLE FOR DESIGN AND CONSTRUCTION COSTS ASSOCIATED WITH CHANGING THEELECTRICAL SYSTEM TO MATCH UTILIZATION EQUIPMENT.
42. THE MECHANICAL AND PLUMBING CONTRACTORS SHALL FURNISH ALL STARTERS AND CONTROLS FOR THEIR EQUIPMENT.THE ELECTRICAL CONTRACTOR SHALL PROVIDE SAFETY SWITCHES AND CIRCUIT BREAKERS AND PROVIDE WIRING ANDCONNECTIONS TO THE LINE SIDE OF SAFETY SWITCHES AND/OR CIRCUIT BREAKERS. THE CONTRACTOR PROVIDING THEEQUIPMENT SHALL PROVIDE LOAD SIDE WIRING AND CONNECTIONS TO EQUIPMENT. THE MECHANICAL AND PLUMBINGCONTRACTORS SHALL PROVIDE ALL CONTROL WIRING AND CONNECTIONS AND DEVICES FOR THEIR EQUIPMENT.
43. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL EQUIPMENT TERMINATIONS, PLUGS AND CORDSETS WITH VENDOREQUIPMENT AND VERIFY ALL DEVICE LOCATIONS FOR SPECIALITY EQUIPMENT WITH CASEWORK PRIOR TO ROUGH-IN.
44. TELECOMMUNICATIONS AND DATA CABLES WILL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. LEAVE PULL WIRES ORROPES OF ADEQUATE TENSILE STRENGTH IN ALL EMPTY CONDUITS.
45. INSTALLATION INFORMATION PACKED WITH LIGHTING FIXTURES, DEVICES AND EQUIPMENT SHALL BE RETAINED FORINCLUSION IN THE OPERATIONS AND MAINTENANCE MANUALS.
46. PROTECT ALL EXISTING POWER, COMMUNICATIONS, DATA, LIFE SAFETY SYSTEMS, FIRE ALARM AND PUBLIC ADDRESSSYSTEMS AND MAINTAIN THEM IN OPERATION THROUGHOUT THE PROGRESS OF THE WORK. NOTIFY THE OWNER ANDARCHITECT/ENGINEER IF SHUTDOWNS ARE REQUIRED PRIOR TO ANY OUTAGE OF SERVICE. WHERE THE DURATION OF APROPOSED OUTAGE CANNOT BE TOLERATED BY THE OWNER, PROVIDE TEMPORARY CONNECTIONS AS REQUIRED TOMAINTAIN SERVICE.
47. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING NECESSARY TO INSTALL ALL EQUIPMENT AS REQUIREDAND SHALL REESTABLISH ALL FINISHES TO THEIR ORIGINAL CONDITION WHERE CUTTING AND PATCHING OCCUR. ALLCUTTING AND PATCHING SHALL BE DONE IN A THOROUGHLY WORKMANSHIP MANNER. SAW CUT CONCRETE AND MASONRYPRIOR TO BREAKING OUT SECTIONS. ALL PATCHING MATERIALS AND WORKMANSHIP SHALL BE PERFORMED BY TRADESMENEXPERIENCED IN THAT WORK. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT/ENGINEER.
48. CORE DRILL HOLES IN EXISTING CONCRETE WALLS AS REQUIRED.
49. INSTALL WORK AT SUCH TIME AS TO REQUIRE THE MINIMUM AMOUNT TO CUTTING AND PATCHING.
50. CUT OPENINGS ONLY LARGE ENOUGH TO ALLOW EASY INSTALLATION OF THE CONDUIT.
51. ABANDONED POWER WIRING, RACEWAYS AND CONDUCTORS, SHALL BE REMOVED BACK TO THEIR SOURCE. THEACCESSIBLE PORTIONS OF ABANDONED CABLES (VOICE, DATA, VIDEO, ALARM, ETC.) SHALL BE REMOVED.
52. TRACE OUT EXISTING WIRING THAT IS TO BE RELOCATED, OR REMOVED AND PERFORM THE RELOCATION OR REMOVALWORK AS REQUIRED FOR A COMPLETE OPERATING AND SAFE SYSTEM.
53. THE EXISTING ELECTRICAL SYSTEMS DEPICTED ON THESE DRAWINGS HAVE BEEN COMPILED BY THE ENGINEER FROM THEOWNER'S RECORD DRAWINGS AND LIMITED FIELD VERIFICATION OF THE EXISTING CONDITIONS FOR THE PURPOSE OFINDICATING THE WORK REQUIRED AND ARE BELIEVED TO BE CORRECT. NOTWITHSTANDING, THE CONTRACTOR SHALLVERIFY ALL DIMENSIONS, POINTS OF ACCESS AND FIELD CONDITIONS AFFECTING HIS WORK.
54. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING ELECTRICAL SYSTEMS AND THEEXISTING BUILDING. THE SUBMISSION OF THE PROPOSAL BY THE CONTRACTOR SHALL BE CONSIDERED EVIDENCE THAT HEOR HIS REPRESENTATIVE HAS VISITED THE SITE AND BUILDINGS AND NOTED THE LOCATION AND CONDITIONS UNDER WHICHTHE WORK WILL BE PERFORMED AND THAT HE TAKES FULL RESPONSIBILITY OF ALL FACTORS GOVERNING HIS WORK. NOEXTRAS WILL BE CONSIDERED BECAUSE OF ADDITIONAL WORK NECESSITATED BY EXISTING JOB CONDITIONS THAT ARE NOTINDICATED ON THE DRAWINGS.
55. SOME EXISTING RECEPTACLE, LIGHTING OR OTHER LOADS MAY BE SERVED BY CIRCUITS INDICATED TO BE REMOVED. IFSUCH CONDITIONS ARE DISCOVERED, REQUEST THE ARCHITECT/ENGINEER PROVIDE NEW CIRCUIT NUMBER FOR THE LOAD.DO NOT INDISCRIMINATELY CONNECT TO THE NEAREST CIRCUIT.
56. ALL UNUSED OUTLET BOXES SHALL BE REMOVED OR, WITH SPECIFIC APPROVAL OF THE ARCHITECT/ENGINEER, SHALL BEBLANKED WITH STAINLESS STEEL PLATES. ALL OPENINGS IN EXISTING WALLS AND CEILINGS MADE BY THIS CONTRACTORSHALL BE REPAIRED TO AN EQUAL FINISH AS ADJACENT SURFACES.
57. SEE "SELECTIVE DEMOLITION NOTES" FOR ADDITIONAL REQUIREMENTS.
58. SAFETY: COMPLY WITH OSHA AND NEC ARC FLASH PROTECTION REQUIREMENTS.
59. ALL SWITCHES, RECEPTACLE AND LIGHTS SHALL COMPLY WITH ANSI 117.2 FOR ADA REQUIREMENTS.
INDICATES BI-LEVEL SWITCHING, 1 SWITCH SWITCHES OUTSIDE LAMPS, 1 SWITCH SWITCHES INSIDE LAMPS.SS
MANUAL MOTOR STARTER, ELECTRICAL CONTRACTOR SHALL COORDINATE POLES AND SIZE WITHEQUIPMENT
## = AMPERAGE RATING WHEN INDICATED ON DRAWING
DISCONNECT SWITCH, FUSED, HEAVY DUTY, SIZE AS INDICATED ON DRAWINGS (SIZE AS INDICATED IN THEEQUIPMENT CONNECTION SCHEDULE)
##A = DISCONNECT SIZE / # = NUMBER OF POLES / # = NEMA RATING,/##AF = FUSE SIZE
30A/3/3R,W/ 30AF
208/120V
480/277V
SM ##
TRANSFORMER, SIZE AS INDICATED ON DRAWING
EXISTING PANEL BOARD, SURFACE MOUNTED, SIZE and RATINGS AS INDICATED ON PANEL SCHEDULE
SMOKE DETECTOR
LIGHTING FIXTURE SCHEDULEMARK DESCRIPTION. MANUFACTURER/SERIES SIZE/APERTURE VOLTS LAMPS WATTS LENS COLOR MOUNTING HEIGHT BALLAST REMARKS
A LAY-IN VOLUMETRIC LED H.E. WILLIAMS LT SERIES 2'x4' 120 LED'S 40 FROSTED WHITE RECESSED LED DRIVER 14300 LUMENS, 3500K OR APPROVED EQUAL ACRYLIC 0-10V DIMMINGSEE EM NOTE BELOW
B RECESSED LED DOWN LIGHT, SEMI DIFFUSE PRESCOLITE LF8LEDG4 SERIES 8" DIA 120 LED'S 35 WHITE RECESSED LED DRIVER 1, 52000 LUMENS, 3500K OR APPROVED EQUAL 0-10V DIMMINGSEE EM NOTE BELOW
C RECESSED LED DOWN LIGHT, SEMI DIFFUSE PRESCOLITE LF6LEDG4 SERIES 6" DIA 120 LED'S 25 WHITE RECESSED LED DRIVER 1, 51500 LUMENS, 3500K OR APPROVED EQUAL 0-10V DIMMINGSEE EM NOTE BELOW
D FLUSH MOUNT SQUARE LED DOWNLIGHT LAUREN ILLUMINATION L FM SERIES 12" SQUARE 120 LED'S 50 ACRYLIC WHITE RECESSED LED DRIVER 1, 5, 61750 LUMENS, 4000K OR APPROVED EQUAL 0-10V DIMMING
F EXTERIOR SURFACE MOUNTED LED CANOPY LIGHT HUBBELL NRG 4000 SERIES LUMASQUARE II 14" SQUARE 120 LED'S 70 ACRYLIC BRONZE SURFACE LED DRIVER 1, 55872 LUMENS, 4000K, WET LOCATION OR APPROVED EQUAL
G EXTERIOR LED WALLPACK WITH 90 MIN. BATTERY HUBBELL LNC2 SERIES 10.25" WIDE 120 12 LED'S 28 TYPE III BRONZE WALL LED DRIVER 1, 52868 LUMENS, 4000K OR APPROVED EQUAL DIST.SEE EM NOTE BELOW
REMARKS:1. LED SURGE PROTECTION REQUIRED 4. PROVIDE HOUSE SIDE SHIELD2. WET LOCATION 5. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND PROVIDE APPROPRIATE FIXTURE3. DIMMING OPTION AVAILABLE 6. REMOTE DRIVERNOTES:A. LED MODULES SHALL BE REPLACEABLE.B. FIXTURES INDICATED WITH "EM" SHALL HAVE 90 MIN. BATTERY BACK, UL924 LISTEDC. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES REQUIRED FOR INSTALLATION IN EXISTING CONDITIONSD. ELECTRICAL CONTRACTOR SHALL RECEIVE APPROVAL FOR ALL LIGHTING FIXTURES FROM ARCHITECT/OWNER PRIOR TO PURCHASE AND ROUGH-IN.
(X)PANEL: 1-ATYPE: NEMA 1 208 120 V, 3 PH, 4 WIREBOLT-ON MOUNT: FLUSH
LOAD CKT CKT LOAD VA CKT CKT LOADLOAD SERVED VA BKR # A B C # BKR VA LOAD SERVEDAHU-1 40/2 1 2 15/2 CU-1 | | 3 4 | |HP-1 20/2 5 6 20/1 SPRINKLER RECEPTACLE | | 7 360 8 20/1 360 DYE PACK (SEE NOTE 2)SPACE 9 10 20/1 HWHAHU-2 50/2 11 12 20/1 EF-3 | | 13 14 20/1 EF-4SPACE 15 1,000 16 20/1 1,000 GABLE SIGN (SEE NOTE 2)HP-2 40/2 17 18 | | 19 20 30/1 ATM DRIVE-UPSPACE 21 22 20/1 COPY MACHINESPACE 23 500 24 20/1 500 AUTO DOOR OPENER (SEE NOTE 2)SPACE 25 500 26 20/1 500 AUTO DOOR OPENER (SEE NOTE 2)AHU-3 40/2 27 200 28 20/1 200 LIGHTING CONTACTOR (SEE NOTE 2) | | 29 800 30 25/3 800 SITE LIGHTING (SEE NOTE 2)SPARE 31 800 32 | 800 |HP-3 20/2 33 600 34 | 600 | | | 35 36 20/1 LIGHTING CONTACTORPLUGMOLD 20/1 37 38 SPACETV RECEPTACLE 20/1 39 40 SPACESPACE 41 42 SPACENOTES: 1,660 1,800 1,300 TOTAL VOLT AMPS 400 A. BUS (COPPER)1. HVAC & REFRIGERATION EQUIPMENT SHALL USE TYPE HACR BREAKERS. 14 15 11 CONN. AMPS 400 A. MAIN CIRCUIT BREAKER3. USE EXISTING SPARE FOR NEW CIRCUIT.
10 KAIC MIN.
(X)PANEL: 1-BTYPE: NEMA 1 208 120 V, 3 PH, 4 WIREBOLT-ON MOUNT: FLUSH
LOAD CKT CKT LOAD VA CKT CKT LOADLOAD SERVED VA BKR # A B C # BKR VA LOAD SERVEDOFFICE RECEPTACLE 20/1 43 44 20/1 COMPUTER ROOM QUAD RECEPTACLEOFFICE RECEPTACLE 20/1 45 46 20/1 COMPUTER ROOM QUAD RECEPTACLEOFFICE RECEPTACLE 20/1 47 48 20/1 COMPUTER ROOM QUAD RECEPTACLETV RECEPTACLES FRONT AND BACK DOOR 20/1 49 50 20/1 LIGHTSBREAK ROOM RECEPTACLE 20/1 51 52 20/1 COMPUTER ROOM QUAD RECEPTACLECOFFEE RECEPTACLE 20/1 53 54 20/1 DRIVE-UP (OPEN / CLOSE ATM)MICROWAVE 20/1 55 56 20/1 LOBBY LIGHTSREFRIGERATOR 20/1 57 58 20/1 LIGHTSREC 20/1 59 60 20/1 LIGHTSREC 20/1 61 62 20/1 OFFICE FLOOR RECEPTACLESTELLER RECEPTACLE 20/1 63 64 20/1 DRIVE UP CANOPY LIGHTSTELLER RECEPTACLE 20/1 65 66 20/1 DRIVE UP CANOPY LIGHTSLOBBY BAR RECEPTACLE 20/1 67 68 30/1 LANE 1DEAL DRAWER / MIC RECEPTACLE 20/1 69 70 20/1 SPARENIGHT DEPOSIT 20/1 71 72 20/1 OFFICE LIGHTSATM SIGN 20/1 73 74 20/1 ATTIC LIGHTS AND RECEPTACLESLANE 2 30/1 75 76 20/1 SPAREVAULT VENTILATOR 20/1 77 78 20/1 EXTERIOR LIGHTSVAULT RECEPTACLES 20/1 79 80 20/1 SPARESECURITY RECEPTACLE 20/1 81 82 20/1 ROAD SIGNCUBICAL RECEPTACLE 20/1 83 84 20/1 CHANDELIERNOTES: TOTAL VOLT AMPS 400 A. BUS (COPPER)1. HVAC & REFRIGERATION EQUIPMENT SHALL USE TYPE HACR BREAKERS. CONN. AMPS 400 A. MAIN LUGS
10 KAIC MIN.
N:\C
TT\17027-SEC
U O
cean
Isle\17027 E0.d
wg
, 4/5/2017 9:14:37 A
M 4/5/17
Reviewed For Code Compliance
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266
www.cbhfengineers.com
NC# P-0506c
Copyright 2017 CBHF Engineers, PLLC
Engineers, PLLC
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
E-002
ELECTRICALSPECIFICATIONS
Electrical Specifications
260500 GENERAL ELECTRICAL
A. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDSINSOFAR AS THEY APPLY.
1. THE NATIONAL ELECTRICAL CODE, 2014 EDITION2. THE NATIONAL ELECTRICAL SAFETY CODE3. UNDERWRITER'S LABORATORIES, INC., STANDARDS AND APPROVED LISTINGS4. ELECTRICAL TESTING LABORATORIES STANDARDS5. NORTH CAROLINA STATE BUILDING CODE, LATEST EDITION AND REVISIONS6. ALL LOCAL CODES AND ORDINANCES7. NFPA 728. ADA
B. THE CONTRACTOR SHALL OBTAIN ALL PERMITS, LICENSES, INSPECTIONS, ETC., REQUIRED FOR THE WORK AND SHALL PAYFOR SAME. THE CONTRACTOR SHALL FURNISH A FINAL CERTIFICATE OF INSPECTION AND APPROVAL FROM THE AUTHORITYHAVING JURISDICTION PRIOR TO ACCEPTANCE OF THE WORK.
C. ALL WORK SHALL BE DONE BY SKILLED MECHANICS AND SHALL PRESENT A NEAT, TRIM AND WORKMANLIKE FINISH WHENCOMPLETED.
D. COORDINATION: DO NOT SCALE ELECTRICAL DRAWINGS. LOCATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALLREFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT MEASUREMENTS IN THE PLACEMENT OF EQUIPMENT, FIXTURES,OUTLETS, ETC. THE DRAWINGS DO NOT GIVE EXACT DETAILS AS TO ELEVATIONS AND LOCATIONS OF VARIOUS FITTINGS,CONDUIT, ETC., AND DO NOT SHOW ALL OFFSETS AND OTHER INSTALLATION DETAILS WHICH MAY BE REQUIRED.
E. WORK WITH OTHER CONTRACTORS: THE ELECTRICAL CONTRACTOR SHALL MAKE FINAL ELECTRICAL CONNECTIONS FORALL PLUMBING AND HVAC EQUIPMENT.
F. MATERIALS: ALL MATERIALS SHALL BE NEW AND SHALL BEAR THE MANUFACTURER'S NAME, TRADE NAME, AND UL LABELWHERE SUCH A STANDARD HAS BEEN ESTABLISHED FOR THE PARTICULAR MATERIAL. MATERIALS SHALL BE THE STANDARDPRODUCTS OF MANUFACTURER'S REGULARLY ENGAGED IN THE MANUFACTURE OF THE REQUIRED TYPE OF EQUIPMENTAND THE MANUFACTURER'S LATEST APPROVED DESIGN. OTHER MATERIALS AND EQUIPMENT TO BE AS SHOWN ON THEDRAWINGS. WHERE NO SPECIFIC MATERIAL TYPE IS MENTIONED, A HIGH QUALITY PRODUCT OF A REPUTABLEMANUFACTURER MAY BE USED PROVIDED IT CONFORMS TO THE REQUIREMENTS OF THESE SPECIFICATIONS.
J. SUBMITTALS: SUBMITTALS SHALL INCLUDE PRODUCT DATA FOR ALL MATERIALS SPECIFIED AND COMPONENT INDICATEDINCLUDING EACH PANELBOARD, TRANSFORMER, SAFETY SWITCH, ENCLOSED CIRCUIT BREAKER, LIGHTING FIXTURE,BALLAST, LAMPS, OVERCURRENT PROTECTIVE DEVICE, FIRE ALARM SYSTEM, SURFACE RACEWAY, WIREWAY, RACEWAYFITTINGS, WIRING DEVICES AND ACCESSORIES. INCLUDE DIMENSIONS AND MANUFACTURERS TECHNICAL DATA ONFEATURES, PERFORMANCE, ELECTRICAL CHARACTERISTICS, RATINGS AND FINISHES.
K. GUARANTEE: THE CONTRACTOR SHALL GUARANTEE THE MATERIALS AND WORKMANSHIP COVERED BY THESE DRAWINGSAND SPECIFICATIONS FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE TENANT. THE CONTRACTORSHALL REPAIR AND/OR REPLACE ANY PARTS OF ANY SYSTEM THAT MAY PROVE TO BE DEFECTIVE AT NO ADDITIONAL COSTTO THE TENANT WITHIN THE GUARANTEE PERIOD.
260519 CONDUCTORS
A. CONDUCTORS SHALL BE COPPER, MINIMUM SIZE #12. SIZES #10 AND #12 SHALL BE SOLID, #8 AND LARGER, STRANDED.INSULATION SHALL BE TYPE THW, THWN OR THHN FOR FEEDERS, TYPE THWN OR THHN FOR BRANCH CIRCUITS.
B. CONDUCTORS SHALL BE COLOR CODED THROUGHOUT, SIZES #10 AND #12 SHALL BE FACTORY CODED, SIZES #8 ANDLARGER MAY BE COLOR TAPED ON THE JOB. COLOR CODING SHALL BE: PHASE A - BLACK, PHASE B - RED, PHASE C - BLUE,NEUTRAL - WHITE, GROUND - GREEN FOR 120/208 VOLT SYSTEMS.
C. CONDUCTORS SHALL MEET THE LATEST REQUIREMENTS OF NEMA AND IPCEA AND SHALL BE UL APPROVED.D. ALL CONDUCTORS SHALL BE CONTINUOUS WITHOUT SPLICE BETWEEN JUNCTION, OUTLET, DEVICE BOXES, ETC., UNLESS
NOTED OTHERWISE. NO SPLICING WILL BE PERMITTED IN PANELBOARD CABINETS, SAFETY SWITCHES, ETC.E. TRENCHING: DIRECT BURIED RACEWAYS SHALL BE 24" DEEP TO THE TOP OF THE RACEWAY. TRENCH IN COMPLIANCE WITH
LOCAL CODES AND REGULATIONS. BACKFILL TO 95% COMPACTION AND RESOD GRASSED AREAS TO MATCH EXISTING.F. MARKER TAPE: ALL UNDERGROUND CONDUCTORS SHALL BE IDENTIFIED BY UNDERGROUND LINE MARKING TAPE LOCATED
DIRECTLY ABOVE THE CONDUCTORS AT 6 TO 8 INCHES BELOW FINISHED GRADE. TAPE SHALL BE PERMANENTBRIGHT-COLORED, CONTINUOUS FOIL BACKING SUITABLE FOR USE WITH METAL DETECTION DEVICES, FOR DIRECT BURIALNOT LESS THAN 8 INCHES AND 4 MILS THICK. PRINTED LEGEND SHALL BE INDICATIVE OF TYPE OF UNDERGROUND LINEBELOW.
260533 RACEWAYS AND FITTINGS
A. RACEWAYS SHALL BE RIGID GALVANIZED STEEL, ELECTRICAL METALLIC TUBING AND/OR SCHEDULE 40 PVC WITHAPPROPRIATE FITTINGS. EMT FITTINGS SHALL BE HEX NUT STEEL COMPRESSION TYPE WITH INSULATED THROATS.
B. MC CABLE WITH INSULATED GROUND CONDUCTOR MAY BE USED FOR BRANCH CIRCUITS. DO NOT USE WHERE SUBJECT TOPHYSICAL DAMAGE, OR WHERE EXPOSED TO CORROSIVE CONDITIONS.
C. FLEXIBLE METAL CONDUIT AND LIQUIDTIGHT FLEXIBLE METAL CONDUIT: UL APPROVED AND LABELED WITH HEX NUT STEELFITTINGS.
D. JUNCTION AND OUTLET BOXES FOR INTERIOR USE IN DRY LOCATIONS SHALL BE ZINC COATED OR CADMIUM PLATED SHEETSTEEL, 4" SQUARE BY 2-1/8" DEEP, EXCEPT SINGLE WIRING DEVICE BOXES MAY BE SINGLE GANG.
E. RACEWAYS, BOXES, FITTINGS, ETC., SHALL BE SOLIDLY FASTENED TO MASONRY WITH LEAD ANCHORS AND MACHINESCREWS OR TOGGLE BOLTS. RACEWAYS SHALL BE FASTENED TO STRUCTURAL STEEL WITH BEAM CLAMPS, CONDUITHANGERS, TRAPEZE HANGERS, OR OTHER APPROVED DEVICES.
F. BOXES INSTALLED IN CONCEALED LOCATIONS SHALL BE SET FLUSH WITH THE FINISHED SURFACES AND SHALL BEPROVIDED WITH EXTENSION RINGS [OR PLASTIC COVERS] WHERE REQUIRED. BOXES SHALL BE RIGIDLY INSTALLED.
G. RACEWAYS PASSING THROUGH RATED WALLS, FLOORS, ETC., SHALL BE INSTALLED IN ACCORDANCE WITH PUBLISHED ULCONFIGURATIONS.H. RACEWAYS SHALL BE SIZED AS SHOWN AND/OR AS REQUIRED BY THE NEC. MINIMUM SIZE SHALL BE 1/2".I. RACEWAY AND BOX INSTALLATION:
1. OUTDOORS (EXPOSED): USE RIGID STEEL, IMC OR SCHEDULE 40 PVC. RIGID STEEL WHERE SUBJECT TO PHYSICALDAMAGE.
2. OUTDOORS (CONCEALED): USE RIGID STEEL, IMC OR SCHEDULE 40 PVC.3. INDOORS (EXPOSED): USE EMT, RIGID STEEL OR IMC. RIGID STEEL WHERE SUBJECT TO PHYSICAL DAMAGE.4. INDOORS (CONCEALED): USE EMT, IMC OR RIGID STEEL OR MC CABLE WITH INSULATED GROUND.5. BOXES AND ENCLOSURES
a. INDOORS: NEMA 250, TYPE 1b. OUTDOORS: NEMA 250, TYPE 3R.
260534BOXES
A. JUNCTION, SWITCH, RECEPTACLE AND OUTLET BOXES FOR INTERIOR USE IN DRY LOCATIONS SHALL BE ZINCCOATED OR CADMIUM PLATED SHEET STEEL, 4" SQUARE AND 2-1/8" DEEP, UNLESS OTHERWISE INDICATED ONTHE CONTRACT DRAWINGS. EXTERIOR AND EXPOSED BOXES SHALL BE CAST TYPE WITH HUBS. SMALLER ANDSHALLOWER OUTLET BOXES WILL BE PERMITTED ONLY BY SPECIAL PERMISSION OF THE ARCHITECT/ENGINEERWHERE SUCH BOXES ARE NECESSARY DUE TO STRUCTURAL CONDITIONS ENCOUNTERED. WHERE LARGERJUNCTION BOXES ARE REQUIRED, THEY SHALL BE FABRICATED FROM NO. 10, 12, 14 OR 16 GAUGE SHEETSTEEL AS REQUIRED BY THE UNDERWRITER'S LABORATORIES, INC., AND GALVANIZED AFTER FABRICATION.
B. USE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. USE STAMPED STEEL BRIDGES TO FASTEN FLUSHMOUNTING OUTLET BOX BETWEEN STUDS, CADDY RBS SERIES OR EQUIVALENT.C. ALL JUNCTION BOXES SHALL HAVE SCREW FASTENED COVERS. OUTLET BOXES SHALL BE PROVIDED WITHEXTENSION PLASTER RINGS WHERE REQUIRED BY STRUCTURAL AND FINISH CONDITIONS.D. SET WALL MOUNTED BOXES AT ELEVATIONS TO ACCOMMODATE MOUNTING HEIGHTS INDICATED AND SPECIFIED INSECTIONFOR OUTLET DEVICE. BOXES ARE SHOWN ON DRAWINGS IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. ADJUST BOXLOCATION UP TO 10 FEET (3 M) IF REQUIRED TO ACCOMMODATE INTENDED PURPOSE. INSTALL PULL BOXES AND JUNCTIONBOXES ABOVE ACCESSIBLE CEILINGS AND IN UNFINISHED AREAS ONLY. COORDINATE MOUNTING HEIGHTS AND LOCATIONSOF OUTLETS MOUNTED ABOVE COUNTERS, BENCHES, AND BACKSPLASHES.E. INSTALL BOXES TO PRESERVE FIRE RESISTANCE RATING OF PARTITIONS AND OTHER ELEMENTS, USING APPROVEDMATERIALS AND METHODS.
262726 WIRING DEVICES
A. PROVIDE COMMERCIAL SPECIFICATION GRADE RECEPTACLES AND SWITCHES IN WHITE WITH WHITE COVERPLATESDIMMERSWITCHES SHALL BE TOGGLE SWITCHES WITH SLIDE DIMMERS. ALL DEVICES SHALL BE RATED 20 AMPERES. PROVIDEMATCHING PLASTIC DEVICE PLATES. EXTERIOR RECEPTACLES SHALL BE WEATHER RESISTANT TYPE, GFI AND INSTALLED INWEATHERPROOF WHILE-IN-USE COVER.B. OCCUPANCY SENSORS: OCCUPANCY SENSORS SHALL UTILIZE DUAL TECHNOLOGY SENSING. ACCEPTABLE TECHNOLOGYIS PASSIVE INFRARED (PIR), ULTRASONIC AND MICROPHONIC. DUAL TECHNOLOGY IS REQUIRED UTILIZING PIR AND ONE OF THEOTHER TECHNOLOGIES. SENSORS SHALL AUTOMATICALLY ADJUST TIME DELAYS AND SENSITIVITY BASED ON THE ACTIVITYLEVEL IN THE SPACE. ALL SWITCHES SHALL BE APPROVED BY A THIRD PARTY AGENCY, APPROVED FOR THE VOLTAGE ANDCURRENT INDICATED. SENSORS SHALL BE COMPATIBLE WITH ALL LOAD TYPES, INCLUDING ELECTRONIC AND COMPACTFLUORESCENT BALLASTS, INCANDESCENT OR FLUORESCENT AND REQUIRE NO MINIMUM LOAD.
1. WALL SWITCH LINE VOLTAGE SENSORS FOR SMALL AREAS: LINE VOLTAGE, SINGLE GANG, WALL MOUNTEDOCCUPANCY SENSOR SWITCH WITH ONE OVERRIDE SWITCH. SENSOR SHALL RECESS INTO SINGLE GANG SWITCHBOX AND FIT A STANDARD GFI RECEPTACLE PLATE OPENING. SWITCHES SHALL BE COMPATIBLE WITH STANDARDTHREE AND FOUR-WAY TOGGLE SWITCHES. PROVIDE HARD LENS SWITCHES IN STORAGE ROOMS AND OTHERLOCATION SUBJECT TO ABUSE. ADJUSTABLE TIME DELAY OF 20 MINUTES, 180 DEGREE FIELD OF VIEW, MINIMUMCOVERAGE AREA OF 900 SF. VOLTAGE: 120-277 VOLTS AC, MINIMUM LOAD RATING 800 WATTS AT 120 VAC, 1200WATTS AT 277 VAC. HUBBELL AT120 OR AT277 OR EQUAL BY SENSOR SWITCH OR WATTSTOPPER.
2. CEILING MOUNTED LOW VOLTAGE SENSORS FOR LARGE AREAS: LOW VOLTAGE, RECESS CEILING MOUNTEDOCCUPANCY SENSOR SWITCH SHALL OPERATE IN CONJUNCTION WITH A LINE VOLTAGE POWER PACK TO CONTROL
THE CONNECTED LIGHTING LOADS. SENSORS SHALL OPERATE ON A CLASS 2, THREE-CONDUCTOR CABLE SYSTEM.MULTIPLE SENSORS SHALL BE CONNECTABLE TO A SINGLE POWER PACK. SENSOR SHALL RECESS INTO A TWOGANG OUTLET BOX. ADJUSTABLE TIME DELAY OF 1 - 15 MINUTES. HUBBELL ATD1000C OR ATD500C FOR SPACESLESS THAN 500 SQUARE FEET, OR EQUAL BY SENSOR SWITCH OR WATTSTOPPER. POWER PACKS SHALL BE RATED20A AT 120-277 VOLTS AND SHALL BE COMPATIBLE WITH ALL LOAD TYPES, INCLUDING ELECTRONIC AND COMPACTFLUORESCENT BALLASTS, INCANDESCENT OR FLUORESCENT. THEY SHALL HAVE THE CAPACITY TO POWERADDITIONAL REMOTE HEADS OR ADDITIONAL RELAYS. POWER PACKS MAY BE PARALLELED TO ACCOMMODATEEXTRA LOAD OR MORE THAN THREE HEADS OR ADDITIONAL RELAYS. ADDITIONAL RELAY SHALL BE USED WHERETHERE IS MORE THAN ONE CIRCUIT BEING CONTROLLED OR WHERE THERE IS A NEED TO CONTROL MULTIPLEVOLTAGES. HUBBELL CUL20A -(120V) OR HUBBELL CU277A-(277V) (ADDITIONAL RELAY FOR MULTIPLE CIRCUITAPPLICATIONS HUBBELL AAR), OR EQUAL BY SENSOR SWITCH OR WATTSTOPPER.
260526GROUNDING
C. ALL GROUNDING SHALL BE IN ACCORDANCE WITH ARTICLE 250 OF THE NEC. IN ADDITION, THE FOLLOWINGREQUIREMENTSSHALL BE MET:
1. GROUNDING CONDUCTORS SHALL BE INSTALLED AS TO PERMIT THE SHORTEST AND MOST DIRECT PATH FROMEQUIPMENT TO GROUND. ALL GROUND CONNECTIONS TO GROUND CONDUCTORS SHALL BE ACCESSIBLE.
2. EQUIPMENT GROUND CONTINUITY SHALL BE MAINTAINED THROUGH FLEXIBLE METAL CONDUIT.3. ALL WIRING DEVICES EQUIPPED WITH GROUNDING CONNECTION SHALL BE SOLIDLY GROUNDED TO GROUND
SYSTEM WITH GROUNDING CONDUCTORS.4. THE FRAME OF ALL LIGHTING FIXTURES SHALL BE SECURELY GROUNDED TO THE EQUIPMENT GROUND SYSTEM
WITH GROUNDING CONDUCTORS.5. GROUNDING TYPE CONVENIENCE OUTLETS AND SWITCHES SHALL BE SOLIDLY GROUNDED TO
EQUIPMENGROUNDING SYSTEM WITH A GREEN COLORED INSULATED CONDUCTOR. ELECTRICAL CONNECTIONSSHALL BE CONTINUOUS FROM EQUIPMENT GROUND BUS IN PANELBOARD TO THE HEX NUT ON THE CONVENIENCEOUTLET OR SWITCH.
6. ALL CIRCUITS SHALL CONTAIN AN INSULATED, GREEN, COPPER GROUNDING CONDUCTOR, SIZED IN ACCORDANCE WITH TABLE 250-122 OF THE NEC. GROUNDING CONDUCTORS SHALL BE CONNECTED TO EQUIPMENT GROUND BUS IN PANELBOARD AND SECURELY ATTACHED AND GROUNDED TO THE DEVICE OR ENCLOSURE AT THE OTHER END.
7. ALL EQUIPMENT ENCLOSURES, AND NON-CURRENT METALLIC PARTS OF ELECTRICAL EQUIPMENT, RACEWAY SYSTEMS, ETC., SHALL BE EFFECTIVELY AND ADEQUATELY BONDED TO GROUND.
260529 SUPPORTING DEVICES
A. PROVIDE MATERIALS, SIZES, AND TYPES OF ANCHORS, FASTENERS AND SUPPORTS TO CARRY THE LOADS OF EQUIPMENT AND CONDUIT. CONSIDER WEIGHT OF WIRE IN CONDUIT WHEN SELECTING PRODUCTS. PROVIDE ADEQUATE CORROSION RESISTANCE.B. ANCHORS AND FASTENERS:
1. CONCRETE STRUCTURAL ELEMENTS: USE EXPANSION ANCHORS.2. STEEL STRUCTURAL ELEMENTS: USE BEAM CLAMPS.3. CONCRETE SURFACES: USE SELF_DRILLING ANCHORS AND EXPANSION ANCHORS.4. HOLLOW MASONRY, PLASTER, AND GYPSUM BOARD PARTITIONS: USE TOGGLE BOLTS.5. SOLID MASONRY WALLS: USE EXPANSION ANCHORS.6. SHEET METAL: USE SHEET METAL SCREWS OR BOLTS7. WOOD ELEMENTS: USE WOOD SCREWS.
C. INSTALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.D. PROVIDE ANCHORS, FASTENERS, AND SUPPORTS IN ACCORDANCE WITH NECA “STANDARD OF INSTALLATION”.E. DO NOT FASTEN SUPPORTS TO PIPES, DUCTS, MECHANICAL EQUIPMENT, AND CONDUIT.
F. DO NOT USE POWDER_ACTUATED ANCHORS.G. OBTAIN PERMISSION FROM ARCHITECT/ENGINEER BEFORE DRILLING OR CUTTING STRUCTURAL MEMBERS.H. FABRICATE SUPPORTS FROM STRUCTURAL STEEL OR STEEL CHANNEL. RIGIDLY WELD MEMBERS OR USE HEXAGON HEADBOLTS TO PRESENT NEAT APPEARANCE WITH ADEQUATE STRENGTH AND RIGIDITY. USE SPRING LOCK WASHERS UNDERALL NUTS.I. INSTALL SURFACE_MOUNTED CABINETS AND PANELBOARDS WITH MINIMUM OF FOUR ANCHORS.J. IN WET AND DAMP LOCATIONS USE STEEL CHANNEL SUPPORTS TO STAND CABINETS AND PANELBOARDS ONE INCH (25MM)OFF WALL.K. CONDUITS INSTALLED ON THE INTERIOR OF EXTERIOR BUILDING WALLS SHALL BE SPACED AWAY FROM THE WALLSURFACEA MINIMUM OF 1/4 INCH (65MM) USING “CLAMP-BACKS” OR STRUTS.L. USE SHEET METAL CHANNEL TO BRIDGE STUDS ABOVE AND BELOW CABINETS AND PANELBOARDS RECESSED IN HOLLOWPARTITIONS.
260553IDENTIFICATION
A. WIRE MARKERS1. MULTIWIRE BRANCH CIRCUIT PHASE CONDUCTORS SHALL BE CLEARLY IDENTIFIED IN EACH BRANCH CIRCUIT
PANELBOARD. ATTACH A YELLOW FLAG TYPE PLASTIC CABLE TIE TO EACH PHASE CONDUCTOR OF A MULTIWIREBRANCH CIRCUIT AT APPROXIMATELY 2" FROM THE CIRCUIT BREAKER TERMINAL. INSTALL A YELLOW WITH BLACKLETTER IDENTIFICATION LABEL IN THE PANELBOARD DOOR STATING "YELLOW CABLE TIE FLAGS ON CONDUCTORSINDICATE THE CONDUCTOR IS PART OF A COMMON NEUTRAL MULTIWIRE BRANCH CIRCUIT. DO NOT MOVECONDUCTOR TO ANOTHER BREAKER".B. IDENTIFICATION NAMEPLATES: FURNISH AND INSTALL ENGRAVED LAMINATED PHENOLIC NAMEPLATES FOR ALL SAFETYSWITCHES, PANELBOARDS AND ELECTRICAL EQUIPMENT SUPPLIED FOR IDENTIFICATION OF EQUIPMENT CONTROLLED,SERVED, PHASE, VOLTAGE, ETC. NAMEPLATES SHALL BE SECURELY ATTACHED TO EQUIPMENT WITH METAL SCREWS ANDSHALL IDENTIFY BY NAME THE EQUIPMENT CONTROLLED, ATTACHED, ETC. LETTERS SHALL BE APPROXIMATELY 1/4-INCHHIGH MINIMUM. EMBOSSED, SELF-ADHESIVE PLASTIC TAPE IS NOT ACCEPTABLE. NAMEPLATE MATERIAL COLORS SHALL BEBLACK SURFACE WITH WHITE CORE FOR THE NORMAL POWER SYSTEM.C. RECEPTACLE CIRCUIT IDENTIFICATION: PROVIDE ADHESIVE BACKED, LAMINATED PLASTIC RECEPTACLE DEVICE PLATELABELS IDENTIFYING THE CIRCUIT FEEDING THE DEVICE. LABELS SHALL BE LABEL MACHINE PRINTED, BLACK LETTERING ONA CLEAR BACKGROUND, TO INDICATE PANEL AND CIRCUIT NUMBER AND SHALL BE CASIO, BROTHER, T&B OR APPROVEDEQUAL. PRINT CIRCUIT NUMBER ON FLAG TYPE PLASTIC CABLE TIE WITH A PERMANENT MARKER (SHARPIE, ETC.) ANDATTACH TO CONDUCTORS IN OUTLET BOX. FLAG SHALL BE READILY VISIBLE UPON REMOVAL OF DEVICE PLATE. LOCATION:EACH RECEPTACLE DEVICE PLATE. APPLY CENTERED ON THE LOWER PORTION BELOW THE RECEPTACLE, PARALLEL TOTHE LOWER SURFACE. LEGEND: TYPED LABELS TO INDICATE PANEL AND CIRCUIT NUMBER FEEDING THE DEVICE (I.E.,RPA-24).
262817 CIRCUIT BREAKERS
A. ENCLOSED CIRCUIT BREAKERS SHALL BE MOLDED CASE, UL LISTED AND SHALL BE RATED AS SHOWN ON THE DRAWINGSWITH APPROPRIATE WITHSTAND RATINGS AND CURRENT LIMITING CHARACTERISTICS AS REQUIRED TO SAFELY FUNCTIONAND PROTECT THE DISTRIBUTION SYSTEM. ACCESSORIES SHALL BE PROVIDED AS NOTED OR REQUIRED AND SHALL BE ULLISTED AND FIELD INSTALLABLE.B. CIRCUIT BREAKERS SHALL BE MANUFACTURED BY CUTLER HAMMER, GENERAL ELECTRIC, SIEMENS OR SQUARE D
3600 AUTOMATIC TRANSFER SWITCHES
A. AUTOMATIC TRANSFER SWITCHES SHALL BE ELECTRICALLY OPERATED, MECHANICALLY HELD, KOHLER KCSSERIES OR PRE APPROVED EQUAL. SWITCHES SHALL CONFORM TO THE REQUIREMENTS OF UL 1008, NFPA 70,NFPA 110, IEEE 446 AND NEMA STANDARD ICS10-2005.B. RATINGS: AS SHOWN ON THE DRAWINGS (CONTINUOUS DUTY). UL 1008 LISTED. THREE POLE, SOLID NEUTRAL.INTERRUPTING CAPACITY: 600 PERCENT OF CONTINUOUS RATING. THREE CYCLE WITHSTAND CURRENT RATINGSHALL BE AS DEFINED BY UL 1008. TRANSFER TIME: NOT TO EXCEED 1/6 SECOND. NEMA-1 FLOOR OR WALLMOUNTED ENCLOSURE AS INDICATED.C. SERVICE CONDITIONS: NEMA ICS 1.D. THE TRANSFER SWITCH MANUFACTURER SHALL BE RESPONSIBLE FOR PROVIDING THE COORDINATING WIRINGDIAGRAMS SHOWING THE ELECTRICAL CONNECTIONS BETWEEN THE TRANSFER SWITCH AND THEENGINE-GENERATOR SET FOR USE BY THE E-G SET SERVICE PERSONNEL DURING INSTALLATION AND CHECKOUTOF THE EQUIPMENT.E. CONSTRUCTION: TRANSFER SWITCHES SHALL BE RIGIDLY CONSTRUCTED TO CLOSE INTO AND WITHSTAND THEBOLTED FAULT CURRENT AVAILABLE AT THE SWITCH. ALL TRANSFER SWITCH COILS, SPRINGS, AND CONTROLELEMENTS SHALL BE EASILY INSPECTABLE AND CONVENIENTLY REMOVABLE FROM THE FRONT OF THE TRANSFERSWITCH WITHOUT MAJOR DISASSEMBLY OR DISCONNECTION OF POWER CONDUCTORS. ALL FEEDER LUGS,RELAYS, TIMERS, CONTROL WIRING AND ACCESSORIES SHALL BE FRONT ACCESSIBLE. THE CONTROL MODULEAND TRANSFER SWITCH SHALL BE PHYSICALLY SEPARATED. MAIN CONTACTS SHALL BE OF SILVER ALLOYCOMPOSITIONF. CONTROLS: MICROPROCESSOR TYPE WITH DIGITAL DISPLAY AND USER CONTROL SWITCHES, FRONT PANELMOUNTED. PROVIDE WITH RECHARGEABLE BATTERY BACKUP, SERIAL COMMUNICATIONS PORT, NON-VOLATILEEPROM STORING SETUP AND CALIBRATION DATA, SELF DIAGNOSTICS, ETC. THE CONTROL MODULE SHALL HAVE ATHREE-POSITION, KEY OPERATED PROGRAMMING CONTROL SWITCH. THE KEY SHALL BE REMOVABLE IN ANYPOSITION. THE POSITIONS SHALL BE: OFF: ALLOWS ALL ENABLED ACCESSORIES TO BE MONITORED ONLY.SETTINGS CANNOT BE CHANGED WHILE IN THIS POSITION. LOCAL: ALLOWS ALL ENABLED ACCESSORY SETTINGSTO BE CHANGED LOCALLY AT THE TRANSFER SWITCH CONTROL PANEL. REMOTE: ALLOWS ALL ENABLEDACCEESSORIES TO BE ALTERED VIA THE REMOTE COMMUNICATIONS PORT.
1. TEST SWITCH: MOUNT IN COVER OF ENCLOSURE TO SIMULATE FAILURE OF NORMAL POWER SOURCE.
2. RETURN TO NORMAL SWITCH: MOUNT IN COVER OF ENCLOSURE TO INITIATE MANUAL TRANSFER FROMALTERNATE SOURCE TO NORMAL SOURCE.
3. TRANSFER SWITCH AUXILIARY CONTACTS: 2 NORMALLY OPEN; 2 NORMALLY CLOSED.4. NORMAL SOURCE MONITOR: MONITOR EACH LINE OF NORMAL SOURCE VOLTAGE AND FREQUENCY; INITIATE
TRANSFER WHEN VOLTAGE DROPS BELOW 85 PERCENT OR FREQUENCY VARIES MORE THAN 3 HERTZ FROMRATED NOMINAL VALUE.
5. ALTERNATE SOURCE MONITOR: MONITOR ALTERNATE SOURCE VOLTAGE AND FREQUENCY; INHIBIT TRANSFERWHEN VOLTAGE IS BELOW 85 PERCENT OR FREQUENCY VARIES MORE THAN 3 HERTZ FROM RATED NOMINALVALUE.
6. IN-PHASE MONITOR: INHIBIT TRANSFER UNTIL SOURCE AND LOAD ARE WITHIN 15 ELECTRICAL DEGREES.7. NORMAL AND EMERGENCY POSITION PUSH-TO-TEST INDICATING LIGHTS.8. ENGINE EXERCISER: FULLY PROGRAMMABLE, SOLID STATE TYPE. START ENGINE EVERY 7 DAYS
(PROGRAMMABLE); RUN FOR 30 MINUTES (PROGRAMMABLE) BEFORE SHUTTING DOWN. BYPASS EXERCISER
CONTROL IF NORMAL SOURCE FAILS DURING EXERCISING PERIOD. PROVIDE LOAD/NO-LOAD SWITCH.9. EQUIPMENT BRANCH ATS SHALL PROVIDE THREE SIGNALS TO ALL ELEVATOR CONTROLLERS:
a. ONE SIGNAL FOR LOSS OF NORMAL POWER WHEN ESSENTIAL POWER IS ESTABLISHED.
b. ONE TWENTY SECONDS PRIOR TO RETRANSFER TO NORMAL POWER.
c. ONE TWENTY SECONDS BEFORE SWITCHING FROM NORMAL POWER TO EMERGENCY POWER DURINGTESTING OF THE GENERATOR SYSTEM. COORDINATE MOMENTARY OR MAINTAINED AND OPEN/CLOSEDSTATUS AS REQUIRED BY THE ELEVATOR MANUFACTURER.G. AUTOMATIC SEQUENCE OF OPERATION
1. INITIATE TIME DELAY TO START ALTERNATE SOURCE ENGINE GENERATOR: UPON INITIATION BY NORMALSOURCE MONITOR WHEN SOURCE DROPS BELOW RANGE OF 70-95% OF RATED VOLTAGE (FACTORY SET AT85%). TIME DELAY TO START ALTERNATE SOURCE ENGINE GENERATOR: 0.05 TO 6 SECONDS (FACTORY SET AT3 SECONDS) TO ALLOW FOR MOMENTARY DIPS.
2. INITIATE TRANSFER LOAD TO ALTERNATE SOURCE: UPON INITIATION BY NORMAL SOURCE MONITOR ANDPERMISSION BY ALTERNATE SOURCE MONITOR. GENERATOR VOLTAGE HAS REACHED RANGE OF 75-100% OFRATED VOLTAGE (FACTORY SET AT 90%) AND GENERATOR RATED FREQUENCY OF 85-100% (FACTORY SET AT90%).
3. TIME DELAY BEFORE TRANSFER TO ALTERNATE POWER SOURCE: 0 TO 60 SECONDS, ADJUSTABLE.4. INITIATE RETRANSFER LOAD TO NORMAL SOURCE: UPON PERMISSION BY NORMAL SOURCE AND INPHASE
MONITORS.5. TIME DELAY BEFORE TRANSFER TO NORMAL POWER: 0 TO 30 MINUTES, ADJUSTABLE; BYPASS TIME DELAY IN
EVENT OF ALTERNATE SOURCE FAILURE.6. TIME DELAY BEFORE ENGINE SHUT DOWN: 0 TO 15 MINUTES, ADJUSTABLE, OF UNLOADED OPERATION. TO
ALLOW ENGINE TO COOL BEFORE SHUTDOWN.H. TESTING: DEMONSTRATE OPERATION OF TRANSFER SWITCH IN NORMAL AND EMERGENCY MODES.I. MAINTENANCE SERVICE: PROVIDE SERVICE AND MAINTENANCE OF TRANSFER SWITCHES FOR ONE YEAR FROMDATE OF SUBSTANTIAL COMPLETION.J. WARRANTY: AUTOMATIC TRANSFER SWITCHES AND ASSOCIATED EQUIPMENT SHALL BE WARRANTED BY THEMANUFACTURER FOR A PERIOD OF 1 YEAR FROM THE DATE OF FINAL INSPECTION AND ACCEPTANCE. THEWARRANTY SHALL INCLUDE ALL PARTS, LABOR (INCLUDING TRAVEL), EXPENSES AND EQUIPMENT NECESSARY TOPERFORM REPLACEMENT AND REPAIR.
265100LIGHTING FIXTURES
A. LIGHTING FIXTURE TYPES SHALL BE FURNISHED AS REQUIRED BY THE LIGHTING FIXTURE SCHEDULE AS INDICATED ONTHEDRAWINGS. CATALOG NUMBERS ARE PROVIDED AS A GUIDE TO THE DESIGN AND QUALITY OF FIXTURE DESIRED.EQUIVALENT DESIGNS AND EQUAL QUALITY FIXTURES OF OTHER MANUFACTURERS LISTED WILL BE ACCEPTABLE UPONAPPROVAL OF THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL VERIFY FROM THE CONTRACT DRAWINGS THE TYPECEILINGS OR WALLS THE FIXTURE IS TO BE USED WITH AND SHALL PROVIDE COMPATIBLE MOUNTING ATTACHMENTS ANDTRIM. PROVIDE ALL ACCESSORIES OR ADDITIONAL MATERIALS REQUIRED TO MAINTAIN THE CEILING FIRE RATING ASREQUIRED BY REGULATORY AUTHORITIES.B. ALL FIXTURES SHALL BE INSTALLED COMPLETE WITH LAMPS. LAMPS SHALL BE INDICATED ON THE DRAWINGS.INCANDESCENT LAMPS SHALL BE RATED 120 VOLTS, UNLESS OTHERWISE INDICATED. LED OR FLUORESCENT LAMPS SHALLBE 3500K EXCEPT AS NOTED ON THE DRAWINGS AND/OR SPECIFIED. F032, T-8 FLUORESCENT LAMPS SHALL BE RATED AT2950 MINIMUM LUMENS INITIAL OUTPUT.C. LENSES SHALL BE CLEAR VIRGIN ACRYLIC MATERIAL WITH UNIFORM 3/16" SQUARE BASED FEMALE CONE PRISMS ALIGNED45º TO THE LENGTH AND WIDTH OF THE LENS PANEL. MINIMUM PRISM DEPTH SHALL BE 0.080" WITH A NOMINAL PANELTHICKNESS OF 0.156" AND A MINIMUM OVERALL PANEL THICKNESS OF 0.150" TO 0.160" INCHES.D. BALLASTS SHALL PROVIDE SAFE AND RELIABLE OPERATION OF THE SPECIFIED LAMPS, BE ELECTRONIC TYPE WITHMINIMUMBALLAST FACTOR OF 0.88, OPERATE AT A FREQUENCY OF NOT LESS THAN 20,000 HZ, SOUND RATED "A", WARRANTED FOR APERIOD OF AT LEAST FIVE YEARS, AVERAGE INPUT WATTAGE OF 60 WATTS OR LESS WHEN OPERATING TWO F032T8 LAMPSWHEN TESTED IN ACCORDANCE WITH ANSI C82.2 METHODS, MINIMUM PF NOT LESS THAN 0.90, INPUT CURRENT TOTALHARMONIC DISTORTION LESS THAN 20 PERCENT, INPUT CURRENT THIRD HARMONICS SHALL NOT EXCEED ANSIRECOMMENDATIONS (32% TOTAL HARMONIC DISTORTION, 27.5% OF THE THIRD TRIPLETS), POTTED, MANUFACTURED IN THEU.S.A. AND PROVIDE TRUE PARALLEL LAMP, INSTANT START OPERATION, CASE TEMPERATURE NOT TO EXCEED 25 DEGREESC RISE OVER 40 DEGREES C AMBIENT. MULTI-LEVEL SWITCHED FIXTURES SHALL HAVE MULTIPLE BALLASTS OR SWITCHABLEBALLASTS.
265200EMERGENCY AND EXIT LIGHTING FIXTURES
A. EMERGENCY AND EXIT LIGHTING FIXTURES SHALL BE SELF_CONTAINED UNITS AUTOMATICALLY ACTIVATED WHEN THELINEVOLTAGE DROPS BELOW 80% AND SHALL COMPLY WITH UL 924, NFPA 101 - LIFE SAFETY CODE, NFPA 70 - NEC AND THENCSBC. LIGHTING FIXTURE TYPES SHALL BE FURNISHED AS REQUIRED BY THE LIGHTING FIXTURE SCHEDULE AS INDICATEDON THE DRAWINGS. CATALOG NUMBERS ARE PROVIDED AS A GUIDE TO THE DESIGN AND QUALITY OF FIXTURE DESIRED.EQUIVALENT DESIGNS AND EQUAL QUALITY FIXTURES OF OTHER MANUFACTURERS LISTED WILL BE ACCEPTABLE UPONAPPROVAL OF THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL VERIFY FROM THE CONTRACT DRAWINGS THE TYPECEILINGS OR WALLS THE FIXTURE IS TO BE USED WITH AND SHALL PROVIDE COMPATIBLE MOUNTING ATTACHMENTS ANDTRIM. PROVIDE ALL ACCESSORIES OR ADDITIONAL MATERIALS REQUIRED TO MAINTAIN THE CEILING FIRE RATING ASREQUIRED BY REGULATORY AUTHORITIES.B. ALL FIXTURES SHALL BE COMPLETELY SELF-CONTAINED, PROVIDED WITH MAINTENANCE FREE BATTERY, AUTOMATICCHARGER AND OTHER FEATURES. THEY SHALL BE INSTALLED COMPLETE WITH LAMPS, BATTERIES, ETC. WHICH SHALL BENEW AND UNUSED AT TIME OF FINAL INSPECTION OF THE PROJECT FOR ACCEPTANCE.C. ALL FIXTURES SHALL AUTOMATICALLY, OR MANUALLY UPON DEMAND, CONDUCT SELF TEST ON BATTERY CONDITION(INCLUDING ACTUAL DISCHARGE), CHARGER, LAMPS AND INTERNAL WIRING INTEGRITY PER NEC AND NFPA AT PRESCRIBEDINTERVALS. A PILOT LIGHT SHALL INDICATE THE UNIT IS CONNECTED TO AC POWER. PROVIDE TEST SWITCH AND VISUALINDICATOR(S) OF UNIT OPERATIONAL CONDITION INCLUDING CHARGER STATUS, READY AND SERVICE CODE. TEST SWITCHSHALL SIMULATE OPERATION OF THE UNIT UPON LOSS OF AC POWER BY ENERGIZING LAMPS FROM THE BATTERY, ANDALSO EXERCISE THE TRANSFER RELAY.D. WARRANTY: EACH UNIT SHALL BE WARRANTED FOR THREE YEARS. THE BATTERY SHALL HAVE A ADDITIONAL TWO MOREYEARS PRO-RATED WARRANTY. WARRANTY SHALL DATE FROM THE DATE OF FINAL PROJECT ACCEPTANCE AND BEINCLUDED IN THE CONTRACT DOCUMENT.
270510 TELEPHONE AND DATA
A. COMBINATION TELEPHONE AND DATA OUTLETS SHALL BE PROVIDED AS SHOWN AND SHALL CONSIST OF RJ-45 JACKS IN ANYLON DEVICE PLATE INSTALLED ON A 4" SQUARE X 2 1/8" DEEP BOX WITH 3/4" (MINIMUM) CONDUIT TO THE ACCESSIBLECEILING CAVITY. COORDINATE DEVICE AND DEVICE PLATE COLORS WITH OTHER WIRING DEVICES, INCLUDING SWITCHES,RECEPTACLES, ETC. FOR EACH OUTLET, PROVIDE ONE CAT 6 TELEPHONE CABLE TO THE TELEPHONE BACKBOARD AND ONE(OR MORE AS SHOWN) CAT 6 DATA CABLE(S) TO THE PATCH PANEL ON THE RACK IN THE TELEPHONE/DATA CLOSET.
PROVIDE J HOOK CABLE SUPPORTS AT 4' MAXIMUM INTERVALS TO THE TELEPHONE/DATA CLOSET. TERMINATE ALL CABLES
AND TEST TO CAT 6 PERFORMANCE CRITERIA. LABEL ALL CABLES AND JACKS TO CONFORM TO THE OWNER'S LABELING
SCHEME AND AS REQUIRED BY THE OWNER. PROVIDE WRITTEN TEST RESULTS TO THE ARCHITECT/ENGINEER.INSTALLATION PERSONNEL SHALL BE MANUFACTURER CERTIFIED FOR THE WORK PERFORMED. ALL UTP END-TO-ENDCHANNEL CONFIGURATIONS AS DEFINED BY TIA/EIA 568-B.1,2,3 SHALL BE PROVIDED BY A SINGLE MANUFACTURER. PROVIDEGRAY PATCH CORDS IN ADEQUATE QUANTITY FOR ACTIVE AND 25% SPARE CIRCUITS. PROVIDE SUITABLE CORD LENGTHSFOR EACH DATA OUTLET (6 FOOT MINIMUM) AND FOR ALL PATCH PANEL JACKS. NETWORK DATA CABLE SHALL BE CAT 6BLUE AND TELEPHONE CABLE SHALL BE CAT 6 WHITE, BOTH PLENUM RATED. THE CONTRACTOR SHALL PROVIDE A 20 YEAR
CABLING EXTENDED PRODUCT WARRANTY.
N:\C
TT\17027-SEC
U O
cean
Isle\17027 E0.d
wg
, 4/5/2017 9:14:56 A
M
4/5/17
Reviewed For Code Compliance
J
WP,GFI WP,GFI
EM
ATM SIGN
EM
EM
EM
EM
EM EM
EWH
(X) HOA SWITCH
S
S
(X)PANEL 1-B
(X)PANEL 1-A
S S
ELECTRIC WATERHEATER (ABOVE)
S
S S
SS
SS
SS
S
S
S SSSSS
DOWN LIGHTS IN TALL CEILING AREADOWN LIGHTS OVER TELLERSLIGHT OUTSIDE VAULT2x4 TELLER LIGHTS INBOARD (OUTBOARD)
EM
EM
(4)TOGGLE SWITCHES(1)FOR EACH TELLER LINE& (1) FOR ATM
+84"+84"
PLUG MOLD WITH (12) SINGLE RECEPTACLES(1) ON EITHER SIDE OF WALL
(X)CHANDELIER
1-A-8
X
X
X
X
A A
A A
A
A
A
A
A A
A
AA
A
A A
A A
AA
A A
AA
A
A
A
A
A
DDD
D
D
D
D
D
D
G
WP
(X) (X) (X)
(X)(X)
EMEMB
B B
B
(X)B B
B B B B
B B B B
B B B
BBBB
B B B B
BB
(X)
EMEM
B
B B
B
EMG
C
C
(X)
(X)
A
(X)
(X)
C
C
C
C
EM
F
F F
F
F F F
F
F F
F
F
EM
EM
1-A-16
NEW LIGHTING CONTACTOR
J
1-A-26
J
1-A-24
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266
www.cbhfengineers.com
NC# P-0506c
Copyright 2017 CBHF Engineers, PLLC
Engineers, PLLC
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
OC
EA
N IS
LE B
EA
CH
BR
AN
CH
STA
TE E
MP
LOY
EE
S’ C
RE
DIT
UN
ION
ww
w/c
tt@
ctte
ngin
eerin
g.co
mFi
rm L
icen
se N
umbe
r: F-
0113
910.
397.
2971
Fax
910.
397.
2929
Ph
.W
ilmin
gton
, NC
2840
338
09 P
each
tree
Ave
., Su
ite 1
02CO
NSU
LTIN
G E
NG
INEE
RS
CRIS
ER T
RO
UTM
AN T
ANN
ER
KEYED NOTES1 PROVIDE POWER TO AUTO DOOR OPENER FROM CIRCUIT INDICATED IN PANEL 1-A.
POWER FOR DYE PACK SYSTEM.
REPLACE EXISTING CANOPY LIGHTING WITH FIXTURE TYPE "F".
REPLACE EXISTING WP,GFI RECEPTACLES WITH NEW.
REPLACE EXISTING DUPLEX RECEPTACLE WITH QUADAPLEX. PROVIDE DATE OUTLET WITHCONDUIT. TO NEAREST ACCESSIBLE CEILING.
INSTALL NEW WIRING FROM CANOPY DRIVE THRU SIGNS BACK TO SWITCH LOCATION INDRIVE-THRU TELLER AREA.
PROVIDE NEW CIRCUITING FROM PANEL 1-A TO GABLE SIGN LOCATION. COORDINATE SIGNREQUIREMENTS WITH OWNER.
EXISTING FLOOR MOUNTED RECEPTACLE TO REMAIN.
EXISTING CHANDELIER SHALL REMAIN.
REPLACE ALL EXISTING SWITCHES, RECEPTACLES AND DATA DEVICES WITH WHITE HEAVYDUTY SPEC GRADE WIRING DEVICES, UNLESS NOTED OTHERWISE, TYPICAL FOR ALL,
REPLACE ALL EXISTING LIGHT FIXTURES WITH LIGHT FIXTURES IN THE SAME LOCATION.FIXTURES WITH "EM" SHALL INCLUDE 90 MINUTE EMERGENCY BATTERY BACK-UP.
REPLACE EXISTING SWITCHES WITH DIMMER / OCCUPANCY SENSORS.
REPLACE EXISTING PROGRAMMABLE T-STAT.
1/4" = 1'-0" 0 4' 8'2'A1 FIRST FLOOR PLANPLAN
NORTH
2
4
5
6
7
8
3
1
1
2
3 3 3 3
333
3 3 3
4 4
5
6
6 6 6
6
7
E-101
ELECTRICALFLOOR PLAN
3
3
9
10
11
8
8
8
8
9
12
13
12
12
12
12
12
12
12
1213
13
S
N:\C
TT\17027-SEC
U O
cean
Isle\17027 E1.d
wg
, 4/5/2017 9:45:00 A
M
Reviewed For Code Compliance
top related