specification data profile spoke 40 up | 60 dn led …ps1-a. profile spoke 40 up | 60 dn led (ps1-a)...
Post on 16-Apr-2020
4 Views
Preview:
TRANSCRIPT
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 1 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
PROFILE 4 SPOKE (S4)
PROFILE 3 SPOKE (S3)CATALOG #
PROJECT
NOTES
PERFORMANCE SUMMARY
FEATURES
• Open aperture design with fully luminous interior. No horizontal lenses or diffusers.
• Choice of 120° 3-spoke (S3) or 90° 4-spoke (S4) precision machined, clear anodized aluminum body.
• Five endcap options, preinstalled for perfect fit and finish, with matching sharp or rounded hub corner detail.
• Powered by low voltage stainless steel conductive aircraft cables. No visible power cords.
• Luminaires spaced 12' x 12' deliver 40–50 fc at 0.4 to 0.5 W/ft.
• Direct and direct/indirect general area lighting distributions and independent Up | Dn dimming control available.
• Dynamic white enabled.
42.4% Up | 57.6% Dn
A B C D
Light (lm)S3
3500 4300 5200 6800
Energy (W) 28 34 44 57
Light (lm)S4
4700 5800 7000 9000
Energy (W) 38 46 58 76
Efficacy (lm/W) 128 127 126 123
Color Rendering (CRI) 80+
Color Accuracy (SDCM) < 2
L70 Estimate (h) 200,000
Lumen Maintenance per TM21 (@ 60,000 h) L90
Summary values are nominal and based on 4000K CCT.
3 SPOKE + CAPSULE (P) ENDCAPS
4 SPOKE + BEVEL (B) ENDCAPS
40.7"(1035)
26.2"(666)
47"(1194)
26.2"(666)
39.4"(1000)
39.4"(1000)
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 2 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
1 FAMILY 2 ENDCAP 3OPTICAL DISTRIBUTION
4 ENERGY 1 5 CCT 6 FINISH 3
PS1 Profile Spoke Area A
B
F
P
S
Angle
Bevel
Flat
Capsule
Square
A
B
D
E
F
G
40 Up | 60 Dn
100 Dn
20 Up | 80 Dn
50 Up | 50 Dn
60 Up | 40 Dn
80 Up | 20 Dn
S3
A
B
C
D
28 W
34 W
44 W
57 W 2
S4
A
B
C
D
38 W
46 W
58 W
76 W
30
35
40
W2
3000 K
3500 K
4000 K
2700– 6500 K 9
A
B
S
W
C
Clear Anodized
Black Powdercoat
Metallic Silver Powdercoat
White Powdercoat
Custom Color (RAL)
1 Nominal input power /4ft. For 347 V with E1-4/L1/W1 add 4 W.
2 Single CCT versions only.
3 Matching fixture and canopy finish (silver canopy for clear anodized fixture).
ORDER GUIDE
7 VERSION 8 CEILING TYPE 4 9 DRIVER 10 VOLTAGE 11 SUSPENSION 6
S3
S4
3 Spoke
4 Spoke
D
G
S
R
Drywall
Grid
Structure
Remote
F1
F2
F3
E1
E2
E3
E4
L1
W1
Non-Dim
0–10 V Dim 3% 120–277 V
0–10 V Dim 3% 347 V (Class 2 control wiring)
eldoLED ECO 0–10 V Dim 1%
eldoLED SOLO 0–10 V Dim 0.1%
eldoLED ECO DALI Dim 1%
eldoLED SOLO DALI Dim 0.1%
Lutron Hi-Lume 1% EcoSystem (LDE1)
eldoLED DUAL DALI Dynamic White 0.1% 9
M
3
120–277 V
347 V 5
03
06
12
25
≤ 3 ft
≤ 6 ft
≤ 12 ft
≤ 25 ft
4 Integrated driver with mounting, power feed, suspension + canopy, except for remote.
5 347 V Driver for F1/F3. 347 V Transformer & Driver for E1-4/L1/W1.
6 Tapered suspension cables over 3 ft, see next page.
OPTIONS CONTROLS
WIRING & EMERGENCY 7 SENSORS & CONTROLLERS DYNAMIC WHITE 10
B
C
H
Battery Pack
Chicago Plenum
Emergency Switching(GTD or Controller)
SE1
RE1
VN1
Canopy Integrated Enlighted Smart Sensor 8
Remote Enlighted Smart Sensor
Acuity nLight Converter 9
WF1
WN1
WC1
WC2
WD1
WD2
Fluxwerx Wall Control
Acuity nLight
0–10 V Linear Dim
0–10 V Log Dim
DALI Linear Dim
DALI Inverse Log Dim8 Enlighted with Independent Up | Dn control requires 2 sensors per luminaire. One can be canopy integrated (SE1) but the other must be remote mounted (RE1).
9 nLight in Drywall (D) and Structure (S) ceilings uses remote driver enclosure.7 BP & GTD available for 120–277 V.
10 Dynamic White is available with 40 | 60 (A) & 100 Dn (B) distributions. Use W1 driver. Refer to later section for DW spec & performance details.
1 2 3 4 5 6 7 8 9 10 11 OPTIONS CONTROLS
PS1 A
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 3 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
CANOPIES
SUSPENSION
Powered by low voltage stainless steel conductive aircraft cables.
Canopy finish will match fixture finish unless otherwise specified. Anodized canopies are not available.
3 SPOKEStraight cables up to 3 ft
4 SPOKEStraight cables up to 3 ft
3 SPOKETapered cables over 3 ft
4 SPOKETapered cables over 3 ft
12.5"(318)
(G) Grid
(D) Drywall
0.45"(11)
(S) Structure
(R) Remote
12.5"(318)
2.3"(59)
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 4 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
ENDCAP OPTIONS CROSS SECTION
HUB CORNERS
ROUNDED HUB CORNERSHARP HUB CORNER
2.35"(60)
3.25"(83)
3.1"(79)
Sharp hub corner detail with these endcaps:
– Angle (A)– Bevel (B)– Flat (F)– Square (S)
Rounded hub corner detail with Capsule (P) endcap
(F) FLAT(B) BEVEL
(S) SQUARE
(A) ANGLE
(P) CAPSULE
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 5 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
Enlighted Sensor Option: (D) DRYWALL or (G) GRID
Canopy Integrated SensorSpoke round canopy preinstalled with Enlighted wireless sensor plus separate, large driver enclosure with Enlighted control unit. Plenum rated cable whip and RJ45 plugs enable quick field connection.
Remote SensorEnlighted wireless sensor supplied with Enlighted tile mount collar for remote sensor placement in drywall or ceiling tile. Plenum rated cable whips and RJ45 plugs enable quick field connection.
Enlighted Sensor Option: (S) STRUCTURE or (R) REMOTE
Canopy Integrated SensorSpoke round canopy preinstalled with Enlighted wireless sensor plus separate, large driver enclosure with Enlighted control unit. Plenum rated cable whip and RJ45 plugs enable quick field connection.
Remote SensorEnlighted wireless sensor supplied with tile mount collar for remote sensor placement to a horizontal surface or jBox lid (by others). Plenum rated cable whips and RJ45 plugs enable quick sensor field connection.
(R) REMOTE
• External remote mounted driver
• Powered suspension cable mounts for exposed or recessed junction box
(G) GRID OFF Grid Only
• Integrated Driver + Powered Suspension Cable Mounts
• Integrated Hanger bars for 12, 20 or 24" grid spacing
(D) DRYWALL New or Retrofit
• Integrated Driver + Powered Suspension Cable Mounts
• Requires Structural members on 2 sides
• Default mount tab for 5/8" GWB
(S) STRUCTURE Exposed Ceilings
• Integrated Driver + Powered Suspension Cable Mounts
• For exposed surface conduit or recessed junction box
INTEGRATED DRIVER, MOUNTING, POWER FEEDS + SUSPENSIONRefer to separate product specification datasheets for detailed dimensions of mounting hardware components, driver enclosures, canopies and wiring.
Recessed 120–277 V / Mounting Surface 120–277 V, Mounting + CanopyRecessed 120–277 V / Mounting
Surface 120–277 V, Mounting + Canopy + Driver
Battery Pack or 347 V Option: (D) DRYWALL or (G) GRID
120–277 V 347 V Battery Pack Canopy Integrated Enlighted Sensor
0–10 V Dim Lutron eldoLED Remote Enlighted Sensor
Battery Pack or 347 V Option: (S) STRUCTURE or (R) REMOTE
120–277 V 347 V Battery Pack Canopy Integrated Enlighted Sensor
0–10 V Dim Lutron eldoLED Remote Enlighted Sensor
Driver Enclosure must be in accessible location
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 6 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
CONTROLS & SENSORS
Fluxwerx products are designed for simple integration with a wide range of sensors, lighting controls and building management systems. Many projects incorporate occupancy sensing, daylight harvesting, individual or central adjustment of light levels and luminaire or space monitoring in order to save energy, reduce costs and maximize occupant comfort. Fluxwerx offers a number of standard driver and controller options to support various wired and wireless network protocols. In our suspended products, the packaging of drivers and controls in the mounting system maintains clean aesthetics, simplifies installation & maintenance, increases flexibility and supports future system upgrades.
nLight wired, 2-way network supports luminaire light level control as well as occupancy and daylight sensors. Option: Acuity nLight Converter (VN1) Model: nPS-80-EZ or nPS-80-EZ-ER
Enlighted wireless, networked smart sensor integrates occupancy sensing, daylight harvesting, energy usage, temperature and light level control. Option: Canopy-integrated or remote Enlighted sensor (SE1 or RE1) Model: SU-5E-CL
Lutron EcoSystem network protocol enables on/off, dimming, occupancy sensing and daylight harvesting. Option: EcoSystem Hi Lume 1% (L1)
EldoLED drivers support common wired protocols, 0–10 V and DALI. They also provide access to finer dimming control, dynamic white and Bluetooth low-energy (BLE) wireless. Options: ECO 1% (E1), SOLO 0.1% (E2)
NOTES
CONSTRUCTION
• Anodized, extruded + machined architectural grade aluminum
• Precision machined aluminum joints and endcaps are factory preinstalled for seamless fit
• Stainless steel fasteners
• 0.06” (1.6 mm) low voltage stainless steel conductive aircraft cable suspensions
• Clear anodized surface finish or powdercoated in white, metallic silver or black, (canopies match fixture color as standard — silver for clear anodized)
OPTICAL
• Anidolic optical structures with linear light extraction elements
• Precision molded high transmittance clear acrylic lenses
• Long life mid-flux LED system designed for typical TM21 lumen maintenance ≥ L90 @ 60,000 h
• Available in 3000 K, 3500 K, 4000 K or 2700–6500 K with CRI ≥ 80 and R9 ≥ 0, all with color accurate binning ≤ 2 SDCM
WIRE GAUGE
• Recommended low voltage wire gauge (AWG) for minimal losses over distance when REMOTE mounting:
30 ft | 18 ga
50 ft | 14 ga
80 ft | 12 ga
ENVIRONMENTAL & CARE
• Designed for use in dry or damp indoor locations with ambient temperatures of 0–30° C (32–86° F)
• Not suitable for natatorium environments, e.g. swimming pools, hot tubs and saunas. The luminaire may be damaged by chemicals such as chlorine, solvents, ammonia, alcohol or sulfur in the area of operation or in cleaning products. Damage from contaminants is not covered under warranty.
• Clean only by wiping with a slightly water-damp, soft, clean cloth.
WEIGHT
• 3 Spoke: ~ 23.0 lb (10.4 kg)
• 4 Spoke: ~ 28.0 lb (12.7 kg)
WARRANTY
• 5 year limited warranty on all components and workmanship
INDEPENDENT TESTING
• IESNA LM79
• IESNA LM80 (LED @ 10,000 h)
APPROVALS
• UL Listed (USA + Canada)
• CCEA Chicago Plenum
ELECTRICAL
• No electrical connections are required at fixture level for installation; low voltage power cords factory preinstalled
• High efficiency multivolt drivers, integrated with suspension and mounting components, for 50–60 Hz 120–277 V or 347 V
• Power Factor > 0.90
• Total Harmonic Distortion < 20%
• Dim level: Standard 3%, optional 1% or 0.1%
• Optional Battery Pack delivers 10 W Class 2 rated output for 90 min. Use 12 W input energy to estimate emergency flux, typically 1150–1750 lm (@100–150 lm/W).
• Optional GTD (Generator Transfer Switch), 120–277 V, disables 0–10 V control during emergency for full light output
• Surge Protection: Meets ANSI C82.11 spec and ANSI/IEEE C62.41
• Inrush Current: Meets NEMA 410
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 7 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
A 28 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AA40-S34000 K 3507 27.3 128 83 5.3
< 23500 K 3397 27.3 124 83 5.3REPORT BASED ON
11692617.07 3000 K 3287 27.3 120 83 5.3
B 34 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AB40-S34000 K 4341 34.2 127 83 5.2
< 23500 K 4202 34.2 123 83 5.2REPORT BASED ON
11692617.06 3000 K 4064 34.2 119 83 5.2
C 44 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AC40-S34000 K 5237 41.7 126 83 5.2
< 23500 K 5069 41.7 122 83 5.2REPORT BASED ON
11692617.05 3000 K 4902 41.7 118 83 5.2
D 57 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AD40-S34000 K 6788 55.1 123 83 5.1
< 23500 K 6571 55.1 119 83 5.1REPORT BASED ON
11692617.02 3000 K 6354 55.1 116 83 5.1
PERFORMANCE DATA — 3 SPOKE
Photometric data scaled as 6 feet of linear 4 foot Profile photometry. Distribution plot for each leg of Spoke per Profile linear 4 foot photometry.
42.4% Up | 57.6% Dn
Profile Spoke Suspended PS1-A
4000 K
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 8 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
A 38 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AA40-S44000 K 4676 36.5 128 83 5.3
< 23500 K 4529 36.5 124 83 5.3REPORT BASED ON
11692617.07 3000 K 4382 36.5 120 83 5.3
B 46 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AB40-S44000 K 5788 45.6 127 83 5.2
< 23500 K 5603 45.6 123 83 5.2REPORT BASED ON
11692617.06 3000 K 5418 45.6 119 83 5.2
C 58 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AC40-S44000 K 6982 55.5 126 83 5.2
< 23500 K 6759 55.5 122 83 5.2REPORT BASED ON
11692617.05 3000 K 6536 55.5 118 83 5.2
D 76 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY
(lm) (W) (lm/W) (CRI) (R9) (SDCM)
VERSION
PS1-AD40-S44000 K 9050 73.5 123 83 5.1
< 23500 K 8761 73.5 119 83 5.1REPORT BASED ON
11692617.02 3000 K 8472 73.4 116 83 5.1
PERFORMANCE DATA — 4 SPOKE
Photometric data scaled as 8 feet of linear 4 foot Profile photometry. Distribution plot for each leg of Spoke per Profile linear 4 foot photometry.
42.4% Up | 57.6% Dn
Profile Spoke Suspended PS1-A
4000 K
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 9 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
DYNAMIC WHITE CONTROL OPTIONS
CONTROLS PROTOCOL
CONTROL CURVE
CONTROLS BRAND
DW CODE
CONTROLLER COMPONENTS* (ordered separately)
DALI
Linear
FLUXWERX WF1 Fluxwerx Wall Controller
e.g. Lutron, Crestron WD1
Controller supplied by othersInverse
Loge.g. Distech, Helvar WD2
nLight Linear Acuity WN1
Controller supplied by others
Field-installed nLight converter per driver (supplied with luminaire)
0–10 V
Linear
e.g. Leviton, Watt Stopper, Crestron, Pass & Seymour
WC1
Fluxwerx 0–10 V converter per zone
Log e.g. Lutron, Cooper Controls WC2
FLUXWERX WALL CONTROLLER
SCENE
LIGHT
100% brightness
0.1% brightness
ON/OFF
Scene buttons:Press + hold to save a scene.Press once to recall.
Color Intensity
* See Dynamic White controller data sheet
PROFILE SPOKE 40 UP | 60 DN LED (PS1-A)
PAGE 10 of 10PS1-A | 2019-08
All rights reserved. © Fluxwerx Illumination Inc 2019 604.549.9379 | fluxwerx.comDue to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information.
SPECIFICATION DATA
TYPE
A 38 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-AAW2-S4
2700 K 4040 39.52 102 82.4 4.5
3000 K 4060 38.2 106 83.9 10.7
3500 K 4180 36.88 113 85.9 19.2
REPORT
FLUXWERX
4000 K 4240 36.28 117 86.7 22.9
5000 K 4240 36.44 116 86 17.9
6500 K 4340 39 111 83.7 4.7
B 46 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-ABW2-S4
2700 K 5000 49.6 101 82.4 4.5
3000 K 5040 48.16 105 83.9 10.7
3500 K 5160 46.52 111 85.9 19.2
REPORT
FLUXWERX
4000 K 5240 45.72 115 86.7 22.9
5000 K 5260 45.96 114 86 17.9
6500 K 5360 48.96 109 83.7 4.7
C 58 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-ACW2-S4
2700 K 6020 59.6 101 82.4 4.5
3000 K 6060 57.04 106 83.9 10.7
3500 K 6240 55.08 113 85.9 19.2
REPORT
FLUXWERX
4000 K 6320 54.2 117 86.7 22.9
5000 K 6340 54.44 116 86 17.9
6500 K 6460 58.84 110 83.7 4.7
D 76 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-ADW2-S4
2700 K 7800 79.04 99 82.4 4.5
3000 K 7880 76.4 103 83.9 10.7
3500 K 8080 73.76 110 85.9 19.2
REPORT
FLUXWERX
4000 K 8200 72.56 113 86.7 22.9
5000 K 8220 72.88 113 86 17.9
6500 K 8400 78.04 108 83.7 4.7
DYNAMIC WHITE PERFORMANCE DATA — 4 SPOKE
Photometric data scaled as 6 feet of linear 4 foot Profile Dynamic White photometry. Distribution plot of each leg of Spoke per Profile linear 4 foot photometry.
A 28 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-AAW2-S3
2700 K 3030 29.79 102 82.4 4.5
3000 K 3045 28.53 107 83.9 10.7
3500 K 3135 27.54 114 85.9 19.2
REPORT
FLUXWERX
4000 K 3180 27.09 117 86.7 22.9
5000 K 3180 27.21 117 86 17.9
6500 K 3255 29.4 111 83.7 4.7
B 34 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-ABW2-S3
2700 K 4515 45.66 99 82.4 4.5
3000 K 4545 44.85 101 83.9 10.7
3500 K 4680 43.29 108 85.9 19.2
REPORT
FLUXWERX
4000 K 4740 42.57 111 86.7 22.9
5000 K 4755 42.78 111 86 17.9
6500 K 4845 45.09 107 83.7 4.7
C 44 W CCTLIGHT ENERGY EFFICACY COLOR ACCURACY(lm/4ft) (W/4ft) (lm/W) (CRI) (R9)
VERSION
PS1-ACW2-S3
2700 K 3750 36.51 103 82.4 4.5
3000 K 3780 35.13 108 83.9 10.7
3500 K 3870 33.93 114 85.9 19.2
REPORT
FLUXWERX
4000 K 3930 33.36 118 86.7 22.9
5000 K 3945 33.51 118 86 17.9
6500 K 4020 36.06 112 83.7 4.7
DYNAMIC WHITE PERFORMANCE DATA — 3 SPOKE
Photometric data scaled as 6 feet of linear 4 foot Profile Dynamic White photometry. Distribution plot of each leg of Spoke per Profile linear 4 foot photometry.