software editions - cdvi italia · enterprise cs-ac-ent** sites 1 64 64 64 serial ports 1 1 1 4...

Post on 02-Aug-2020

3 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

OPTION 1:Local Connections

OPTION 2:Dial-up Connection

OPTION 3:TCP/IP Connection

SYSTEM OVERVIEW

w w w . c d v a m e r i c a s . c o m

Every Centaur edition includes a Centaur Server with an administration console, plus all these software modules:Pro-Report with Tracker: On demand, scheduled or customized reportsFrontView: Live interactive fl oor plansFrontGuard: Display real-time visual authenticationFrontCard: Create, modify, delete and print cards, include Photo-IDLocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event

Workstation license(CS-WSLIC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console andall software modules.

LITECS-AC-LITE

StandardCS-AC-STD

ProfessionalCS-AC-PRO**

EnterpriseCS-AC-ENT**

Sites 1 64 64 64

Serial Ports 1 1 1 4

Dial Up - Yes Yes Yes

TCP/IP - Yes Yes Yes

Cards* 512 2,048 8,196 16,384

Controllers* 16 32 64 256

Doors* 16 128 512 2048

* Per site ** Comes with a workstation license

LCD DisplayCK-TRAK-L

(Max. 8 per CT-V900-A)

ElevatorController

CA-A480-A(Max. 8 per CT-V900-A)

RelayExpansion Module

CA-A460-P(Max. 2 per CT-V900-A)

2-DoorExpansion Module

CA-A470-A(Max. 3 per CT-V900-A)

E-BUS NETWORK MODULE CAPACITY

Input 11K Ohm

Input 22.2K Ohm

EOL1K Ohm

Optional Loop Supervision

CONTROLLER INPUTS(UP TO 16 PER CONTROLLER)

+-Power

Supply

+-

+-Power

Supply

+-

Connect directly to controller lock terminals

ELECTROMAGNETIC LOCK OPTION OR DOOR STRIKE OPTION

+

-

+

-

ALARM SOUNDER

2-DOOR CONTROLLER

CT-V900-A

R1/DO

GND

R1/D112VOUT1OUT2OUT5

GREEN

BLACK

WHITEREDYELLOW (green LED)ORANGE (red LED)BROWN (buzzer)

Blue (Clock) Not applicable with Centaur System

R2/DO

GND

R2/D112VOUT3OUT4OUT6

DO

-

D1+V (green LED)R (red LED)B (buzzer)

H (Clock) Not applicable with Centaur System

Connect earth terminal to cold water pipe

Transformer24 VAC, 75VA

50/60Hz Class 2 2 batteries (12V, 7AH) connected in series for

24V backup

+

-

+

-

Reader wiring may differ from diagram. Please consult your dealer for details.!

SERVER TO CONTROLLER COMMUNICATION

Tamper Switch N.C. Contact

To the controller serial port, up to

7.6M (25 ft)

SERIALPORT CABLE(DB9F to DB9F)

RS-485 CONVERTER

To the controller Network, up to

1220M (4000 ft)

GN

D

A+

B-

or

To ServerUSB Port

To ServerSerial Port

To ServerSerial Port

To ServerEthernet Port

To remote modemand

fi rst controller of a site

Telephone line connection

To remote TCP/IP module(CA-ETHR-A) and

fi rst controller of a site

GND

A1+

B1-To next controller

of a site.

+12V

MODULE NETWORK(E-BUS RS-485)Furthest module can be up to 1220M (4000ft) away from the CT-V900-A controller

GND

A2+

B2-

PolycarbonateProximityReaderDGLP FN WLC

Stainless SteelProximity Reader

DGLI WLC

+

-

CONTROLLER NETWORK(RS-485)

CT-V900-A

CT-V900-A2-Door Controller

P O S I T I O N

GNDTXB-

+12V

RXG

NDA+G

ND

RECEIVE

TRANSMIT

POWER

CA-A360-A

CONVERTERSETTINGS

EOL= ON

Bias High/Low JumpersA+= LowB-= Low

CONTROLLER #2SETTINGS

EOL= OFF

Bias High/Low JumpersA+= HighB-= High

CONTROLLER #1SETTINGS

EOL= OFF

Bias High/Low JumpersA+= HighB-= High

CONTROLLER #3SETTINGS

EOL= ON

Bias High/Low JumpersA+= HighB-= High

START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)

END POINTof the RS-485 controller network

CT-V900-A #1

CT-V900-A #2

CT-V900-A2-Door Controller

CT-V900-A #3

CT-V900-A2-Door Controller

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

DEF/R

UN

9.6K/19.2K

ADD

32

ADD

16

ADD

8

ADD

4

ADD

2

ADD

1

1 2 3 4 5 6 7 8

RS-2327.6m (25ft) max.

Addressable dipswitch

Addressable dipswitch

Addressable dipswitch

Example of Jumper Settings

HIGH

HIGH

EOL

EOL

LOW

LOW

Jumper set to LOW

Jumper set to HIGH

Jumper set to EOL ON

Jumper set to EOL OFF

ON

ON

OFF

OFF

BATT

BATTJumper set to OFF

Jumper set to ON

CONTROLLERNETWORK JUMPERS

ADDRESSABLEDIPSWITCH

E-BUSNETWORK JUMPERS

CT-V900-A CUT VIEW

At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF

Note: If you do not use a converter, the first CT-V900-A controller will be the START POINT.

At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

Real-Time ClockLithium Battery Setting

SERVER

CONTROLLER NETWORK

JUMPER & DIPSWITCH SETTINGS

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

+

SP

+12V

R1/

KP

DR

1/K

PC

R1/

KP

BR

1/K

PAO

UT2

OU

T1R

1/D

1R

1/D

0R

1/0V

R1/

+5V

SP

+12V

R2/

KP

DR

2/K

PC

R2/

KP

BR

2/K

PAO

UT4

OU

T3R

2/D

1R

2/D

0R

2/0V

R2/

+5V

ACAC

BAT+BAT-

V+V+V-V-

OUT5OUT6

A+B-

GNDTMPTMP

D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4

CA-A470-A2-Door Expansion Module

LOCK#1

AC OK

EOLBACKUP

SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8

READER#1DATA

READER#2DATA

NO CARD

LOW HIGH

TX RXE-BUS

B-A+

2 CARDSALL CARDSUNLOCK DOOR

20011

10101

AUX OKCOMMCHECK BATTBATT TRBL

LOCK#2

STATUS

JP120350mA/700mA

ON1 2

3 4

5 6

7 8

4

5

1

2

3

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE

ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON

12

34

56

78

ON

NO14

NO13

NC14

NC13

COM16NC15NO15

NO16NC16

COM15

COM14

COM13

NO3

NO4

NC2

NC3

COM1

NC1

NO2

NO1

COM2

COM3

COM4

NC4

NO

7

NO

8

NC

6

NC

7

COM

5

NC

5

NO

6

NO

5

COM

6

COM

7

COM

8

NC

8

NO

11

NO

12

NC

10

NC

11

COM

9

NC

9

NO

10

NO

9

COM

10

COM

11

COM

12

NC

12

A+

GNDB-

TAMPERTAMPER

FC

+12V

AC

BAT+BAT-

AC

+12VGNDGND

FC

RL16RL1

RL2RL3

RL4

RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12

RL13

RL14

RL15

DRM

MO

DULE

BATT REVERSED12V

+12V RELAYBATT

AC

EOL

BLOW HIGH

ALOW HIGH

FC OVERIDE350mA/700mA

E-BUSTXRX

Elevator ControllerCA - A480 - P

E-BUS

EOL= OFF

Bias High/LowA+= HighB-= High

EOL= OFF

Bias High/LowA+= HighB-= High

EOL= OFF

Bias High/LowA+= HighB-= High

EOL= ON

Bias High/LowA+= HighB-= High

EOL= ON

Bias High/Low JumpersA+= LowB-= Low

START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)

END POINTof the RS-485 E-bus network

CT-V900-A2-Door Controller

CT-V900-A

CA-A480-A CA-A480-A

CA-A470-A CA-A470-A

ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8ONOFF

N/D

PULSE 5&6

BACKU

P2

BACKU

P1

L2 Energize

L1 Energize

ADD

2

ADD

1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

ONOFF

PWR

OFF/O

N

DR

M EN

ABLED

RLY O

FF/ON

RLY C

OM

MS

ADD

RESS 8

ADD

RESS 4

ADD

RESS 2

ADD

RESS 1

1 2 3 4 5 6 7 8

At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF

At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH

Addressabledipswitch

Addressabledipswitch

Addressabledipswitch

Addressabledipswitch

E-BUS NETWORK

JUMPER & DIPSWITCH SETTINGS

or

LAN/WAN Network

Fire alarm contact for Lock1 & Lock2

DestinationReporting Module

CA-A482-PThe DRM connects directly

to the CA-A480-A,elevator controller

TCP/IPModule

CA-ETHR-A

RS-485Network HubCA-A370-P

SOFTWARE EDITIONS