Instructions for use

SKF TKTI 20

2 SKF TKTI 20

EC Declaration of conformity ....................................................................................3

Safety recommendations ..........................................................................................4

1. Description .......................................................................................................5

2. Getting started .................................................................................................52.1 Contents.......................................................................................................................... 52.2 Charginginternalbattery............................................................................................. 62.3 Replacingtheinternalbattery.................................................................................... 7

3. Basic features of the SKF Thermal Camera TKTI 20 ..........................................83.1 Hardware........................................................................................................................ 83.2 SwitchingontheTKTI20............................................................................................. 93.3 Focusing.......................................................................................................................... 93.4 Usingthelaserpointer...............................................................................................103.5 Fieldofview..................................................................................................................113.6 Span,Level,Range......................................................................................................11

4. Using the direct access buttons .......................................................................124.1 Directaccessbutton1................................................................................................124.2 Directaccessbutton2................................................................................................154.3 Directaccessbutton3................................................................................................174.4 Directaccessbutton4................................................................................................17 4.4.1 MenuInfraredSettings.................................................................................18 4.4.2 MenuMeasurementOptions........................................................................21 4.4.3 MenuCameraSettings.................................................................................24 4.4.4 MenuAudioSettings.....................................................................................25 4.4.5 MenuImageBrowser....................................................................................26 4.4.6 MenuDate&TimeSettings.........................................................................27 4.4.7 MenuLanguageSelection............................................................................27 4.4.8 MenuDisplaySettings..................................................................................29

5. Saving and annotating pictures.......................................................................305.1 Savingapicture...........................................................................................................305.2 Addingavoicemessage.............................................................................................305.3 AddingaCaption.........................................................................................................31

6. Technical specifications ...................................................................................32

Table of contents

Original instructions

3SKF TKTI 20

EC Declaration of conformity

We, SKFMaintenanceProducts Kelvinbaan16 3439MTNieuwegein TheNetherlands

herewithdeclarethatthefollowingproduct:

SKF Thermal Camera TKTI 20

Conformstothefollowingstandards;

• EMCDirective2004/108/ECasamended“CouncilDirectiveontheapproximationofthelawsoftheMemberStatesrelatingtoelectromagneticcompatibility”asoutlinedinharmonizednorms:EN61000-6-2:2005ImmunityforindustrialenvironmentsEN61000-6-3:2007Emissionstandardforresidential,commercialandlight-industrialenvironments

• CFR47:2009CodeofFederalregulations:Pt15subpartB–RadioFrequencyDevices–UnintentionalRadiators

Thelaserisclassifiedinaccordancetothe21CFR1040.10and1040.11exceptfordeviationspursuanttolasernoticeNo.50datedJune24th2007andcomplieswithIEC/EN60825-1(2001).

Nieuwegein,TheNetherlands,March2011

SébastienDavidManagerProductDevelopmentandQuality

4 SKF TKTI 20

Safety recommendations

Thisproductcomplieswith21CFR1040.10and1040.11exceptfordeviationspursuanttolasernoticeNo.50

datedJune24th2007complieswithIEC/EN60825-1(2001).

Warning• TheequipmentdescribedinthisdocumentusesaClass2laser.

Donotlookdirectlyintothelaserbeamorthelaserbeamexitaperture,irreversibledamagetotheeyemayoccur.Thelasershouldnotbeoperatedwhentherearepersonnelinthecamera’sfieldofview.

Caution• Useofcontrolsoradjustmentsorperformanceofproceduresotherthan

thosespecifiedinthisdocumentmayresultinhazardouslaserradiationexposure.

• Tohelpminimizeburnhazards,beawarethatthermalimagesofhighlyreflectiveobjectswillshowlowerthanactualtemperaturemeasurements.

• Donotuseinamannernotspecifiedinthisinstructionforuse.• Donotuseinexplosiveatmospheres.• Alwaysusethelanyardprovidedtohelpminimisedamagetothe

thermalimagerandpersonalinjuryaccidents.• OnlyusegenuineSKFsparesandaccessories.Othersparesand

accessoriesmaydamagethethermalcamera.• Thethermalcameracontainsnouserserviceableparts.Openingthe

imagercasingvoidswarranty.AllserviceworkmustbecarriedoutbyanauthorisedSKFworkshop.

635nm <1mW <0.2mr

5SKF TKTI 20

1. DescriptionTheSKFTKTI20isadigitalcamerawithadvancedthermalimagingcapabilities.ItisidealforuseasaPredictiveMaintenance(PdM)tool.Thermographyisanon-invasivetechniqueandiswellsuitedformechanicalandelectricalinspections,energyconservationandplantsafetyactivities.TheTKTI20hasalargebacklit31/2”colorscreen,whichgivesaclear,sharpimageusinganyoftheeightcolorpalettes.Designedforeasyoperation,multipletemperaturescanbemeasuredandthedifferencesbetweenthemdisplayed.Otheradvancedmeasurementoptionsarealsoavailable.ImagescanbestoredasradiometricdataanddigitalimagesonthemicroSDcard(supplied).PowerfulPCsoftwaresuppliedwiththeTKTI20,allowstheimagestobefurtheranalyzedandtobeoptimizedforeaseofinterpretation.

2. Getting started

2.1 Contents

12 5 6

4 3

Figure 1. Contents of the case

1 SKFThermalCameraTKTI202 Powersupplyunit(4-6V)and4Internationaladaptors3 CD-Softwareandinstructions(MP5387)4 USBcable(cameratoPC)5 QuickStartguideSKFThermalCameraTKTI20(MP5384)6 CertificateofCalibrationandConformance

Inspectalltheitems.Ifanyitemisdamagedormissing,pleasenotifyyourdealerorlocalSKFofficeimmediately.

6 SKF TKTI 20

2.2 Charging internal battery

• TheTKTI20’sbatterycanbechargedinthecamerabyconnectingthesupplied4-6VpowersupplyunitintotheMiniUSBportinthehatchofthethermalcamera(seefigure2).

• Thebatteryconditionindicatorappearsonthescreenwhentheimagerisswitchedon(seefigure3).

• AgreenLEDwillappearwhilechargingandturnredoncethechargeiscomplete(seefigure2).Afullychargedbatterywillapproximatelylast5hours.

MiniUSBPort

Red=FullGreen=Charginginprogress

Figure 2. Connection ports

TemperatureSpanLevel

Spot Delta Emissivity Reflected Batterytemperature temperature temperature condition(hot&cold)

StatusofDirectaccessbuttonsThewhiteborderediconistheactivefunction.

Figure 3. Screen overview

Thebottommenuwilldisappearafter10seconds,pressanybuttontomakeitreappear.Thegreenrectangleshowstheareawheretemperatureismeasurable.

7SKF TKTI 20

2.3 Replacing the internal battery

TheTKTI20hasafieldreplaceablebattery.

Figure 4: Battery replacement

Openthelockonthebatterycoverandremovethecover,removethebattery,insertanewoneensuringthecontactpadsaretowardsthefrontofthecamera.Replaceandlockthecover.

8 SKF TKTI 20

3. Basic features of the SKF Thermal Camera TKTI 20

3.1 Hardware

TheTKTI20isdesignedforuseasahandheldthermalcamera.ThermalimagesarestoredonamicroSDmemorycard(suppliedsizeis2GB).TheseimagescanbetransferredtoaPCusingtheUSBcableprovidedorviaamicroSDcardreaderconnectedtothePC.PCsoftwareSKFTKTI20ThermalCameraSuiteisincludedforviewingandanalysisofsavedthermalanddigitalimages.

HatchOn/offbutton

4navigationbuttons&

CentretogglebuttonScreen

Directaccessbuttons1to4

Figure 5. Main camera controls

Connectionports:-MiniUSB(Power+PC)

-MicroSD-Headset

Savebutton

Thermalcameralens

Focusring

Digitalcameralens

Light

Figure 6. Front panel

9SKF TKTI 20

3.2 Switching on the TKTI 20

• TheTKTI20isswitchedonandoff bypressingandholdingdownthe powerbutton.

• TheTKTI20takesapproximately 20secondstobefullyoperational.

Figure 7. Camera on/off button

3.3 Focusing

• Sharpentheimagebyrotating thefocusring

Figure 8. Focusing

Focus:• Isthemostimportantsteptoobtainagoodqualityimage• Influencestheaccuracyofthetemperaturereading• IstheonlysettingthatcannotbemodifiedwhenviewingtheimagesonaPCItisadvisedtostayina100%thermalimagemodeforfocusing(seechapter4.2).Somepalettesallowyoutomakeabetterfocus.Makesureyouareinautomaticspanandlevel.

Rotatingthefocusringinaclockwisedirection(fromuserpointofview)focusestheimagesatshorterdistancesdowntoaminimumof30cm.Rotatingthelensintheoppositedirectionfocusestheimageratlongerdistancesuptoinfinity.

Rotatethelensuntiltheimagehasasharpdefinition,withthesharpestcontrastatobjectedges.

10 SKF TKTI 20

Focused Not focused

Figure 9. Focusing

Whenfocusing,afocusbarappearsonthescreenshowingthefocuseddistance.REMEMBERTOREMOVETHELENSCAP

Figure 10. Focus bar

3.4 Using the laser pointer

WhentheTKTI20isswitched‘ON’,thelasermaybeactivatedbypressingandholdingdownthelaserbutton(seefigure11)onthehandle.

Laserpointerbutton

Figure 11. Laser pointer button

Thelaserpointerisusedtoilluminateandidentifyfeaturesintheimage.

Note: Thelasercentreisalignedtoobjectsatadistanceof3m.

11SKF TKTI 20

3.5 Field of view

Figure 12. Field of view

TheTKTI20hasa20˚x15˚fieldofview,anda160x120pixeldetector.Thedetectorresolutioncanbeinterpolatedto320x240(seesection4.4.1;Interpolation).Thefollowingtablegivesanindicationoftheminimumdimensionofanobjectyoucanmeasurethetemperatureatagivendistance.

Distance (m) 0,5 1 5 10 15

Object (cm) 0,3 0,7 3,3 6,6 10

Theobjectsizeisproportionaltothedistance.TheIFOVis2,2mRad.

3.6 Span, Level, Range

TheTKTI20canoperatefrom-10°Cto+250°C;thisistherangeofthecamera.Thespanisdefinedbytheminimumandmaximumtemperaturesonthescaleontherightsideofthescreen.Awiderspanwillgiveyoulessthermaldetails,whereasanarrowerspanwillgiveyougoodthermaldetailsbutalsoincreasesthenoiseintheimage.Youcanadjustitspositionwithintherange,thisisthelevelsetting.

12 SKF TKTI 20

4. Using the direct access buttons

TheDirectaccessbuttonpositionsareshowninthebelowfigure.Theiconwithawhitebordershowstheselectedfunctionthatcanbeadjusted(seealsofigure5):

1 2 3 4

5

6

6

66

Figure 13. Direct access buttons

1 Directaccessbutton1 4 Directaccessbutton42 Directaccessbutton2 5 Centretogglebutton3 Directaccessbutton3 6 4Navigationbuttons

4.1 Direct access button 1

WithDirectaccessbutton1youcanaccess:

a. Alignment (ifvisibleon :seeDirectaccessbutton2).

Asthevisibleandthermalcameraarenotco-axialthevisibleandthermalimageoftenneedtobealigned.Thisisusuallyrequiredwheninspectingobjectsatdifferentdistances.Itispossibletoalignthethermalandvisible(digital)imagesonlyon“Live”mode.Furtheradjustmentscanbedoneonthesavedimageswiththesoftware.

1. PressDirectaccessbutton2tolocatethecameraon/off optionandtogglethecentrebuttontoturnthecameraoptionon.

2. PressDirectaccesbutton1tolocatethealignment option.

3. Alignmentpresetsareaccessiblewithcentretoggle button.Youcanalsousethenavigationbuttonsforfinaladjustment.

13SKF TKTI 20

Align up

Align left Fully aligned Align right

Align down

Figure 14. Examples of alignment

Note: Onlythedigitalimageismoving.

b. Measurement options

TobedisplayedwhilenavigatingwithDirectaccessbutton1,theseoptionsneedtobeenabledintheMeasurementOptionmenu.

ToaccesstheMeasurementOptionmenu

pressDirectaccessbutton4:

andselectthecorrecticon:

14 SKF TKTI 20

Directaccessbutton1candisplaythefollowingicons:

CursoroneMenu>Measurementoptions>Cursors:1

CursortwoMenu>MeasurementOptions>Cursors:2

CursorthreeMenu>MeasurementOptions>Cursors:3

CursorfourMenu>MeasurementOptions>Cursors:4

IsothermlowtempMenu>MeasurementOptions>Isotherms:(Low,High&Low)

IsothermhightempMenu>MeasurementOptions>Isotherms:(High,High&Low)

AreaMenu>MeasurementOptions>Area:On

Hot/coldtrackingMenu>MeasurementOptions>Tracking:(High,Low,High&Low)

Align

(IfCameraOn:seeDirectAccessButton2)

LowtemprangeMenu>MeasurementOptions>Temp.Alarm:(Low,High&Low)

HightemprangeMenu>MeasurementOptions>Temp.Alarm:(High,High&Low)

HorizontalprofileMenu>MeasurementOptions>Temp.Profile:Horizontal

VerticalprofileMenu>MeasurementOptions>Temp.Profile:Vertical

Seefordetaileddescriptionofthefunctionalityoftheseoptionssection4.4.2:MeasurementOptions.

15SKF TKTI 20

4.2 Direct access button 2

Whenapictureisdisplayedonthescreen,thisbuttongivesaccessto3differentoptionswith2settingsforeach(toggleusingcentretogglebutton):

1. Camera on/off

Enable/disablethedisplayofadigitalpictureblendedwith thermalimage.

How to set Blending:

1. PressDirectaccessbutton2tolocatethecameraon/offoption andtogglethecentrebuttontoturnthecameraoptionon.

2. Blendingbetweenthedigitalandthermalimagebypressingthe up/downbuttons

3. Thiswillblendthetwoimagesonapercentagescale0%,25%,50%75%,100%andPictureandPicture(PiP).

4. BlendingisalsopossibleinPiPmode. Youcanadjustthepercentagebypressingtheleft/rightbutton.

100% thermal 25% visible 75% thermal 50% visible 50% thermal

75% visible 25% thermal 100% visible Picture in Picture

2. Light on/off

Enable/disablehighpowerLEDinthefrontpanel, helpfultotakepicturesinadarkenvironment(seefigure6).

16 SKF TKTI 20

3. Temperature range scale

Auto

Automaticallyadjuststheimagetoallowforthehighestandlowest temperatureinthescene.Usefulwhenstartinganimagerandswitchingtodifferentpartsofascene.

Manual

Theuserdefinestherangeoftemperaturestobedisplayed.Manualsettingisusefulwhentheuserwantstoexaminevariouspiecesofsimilarequipment.Inafixedtemperaturerange,anomaliesordiscrepanciescanbepreciselyhighlighted.

Setthespanusingtherightandleftnavigationbuttonandthelevel usingtheupanddownnavigationbutton.

Persistant Manual

Thespanandlevelsettingsareeitherselectedautomaticallybythecameraormanuallybytheuser.Ifthismodeisselected,thecamerastoresthelevelandspansettings.OnpoweringupthedefaultmodeisalwaysAuto,howeverselectingthepersistentmanualmodesetsthelevelandspantothelaststoredvalues.

Setthespanusingtherightandleftnavigationbuttonandthelevel usingtheupanddownnavigationbutton.

17SKF TKTI 20

4. Play audio (only in picture viewing mode) Playspreviouslyrecordedvoiceannotationsavedwiththeimage.

4.3 Direct access button 3

Thisbuttontogglesbetweenliveimageandafrozenimage

4.4 Direct access button 4

Thisbuttonselectsthecameramenus.

Infraredsettings

Measurementoptions

Camerasettings

Image browser

Date &Timesettings

Languageselection

Audio settings

Display settings

18 SKF TKTI 20

Menu selection

1. PressDirectaccessbutton4toenterthemenuselectionscreen

2. Navigatetothedesiredoptionusingthenavigationbuttons. (Theiconwiththeyellowbordershowtheselectedoption)

3. PressDirectaccessbutton3orthecentretogglebuttontoenter theselectedoption.

Menu items

1. Arrowupanddowntothedesireditem

2. Usetheleft/rightarrowstochangethevalueofthisitem3. SelectDirectaccessbutton4toexitorDirectaccessbutton1 togobacktothemainmenu.

4.4.1 Menu Infrared Settings

Emissivity

Differentsurfacescanradiatedifferentamountsofinfraredenergyatthesametemperature.Thisdifferenceintemperaturemeasurementcanbecorrectedbysettingtheemissivityvalue.Theamountofinfraredradiationemittedbyasurfacedependsonbothitstemperatureanditsemissivity.Surfacesthataregoodreflectors(e.g.polishedmetal)arepooremitters,andsurfacesthataregoodemitters(e.g.humanskin)arepoorreflectors.Ablackbodyisdefinedasanobjectthatabsorbsallradiationfallingonitanditisaperfectemitterofradiation.

Theemissivityofasurface(usuallywrittenε)istheratiooftheenergyradiatedbythatsurfacetotheenergyradiatedbyablackbodyatthesametemperature.Foraccuratetemperaturemeasurements,theemissivityofthesurfacebeingmeasuredmustbeenteredintothecamera.Thisisdonebyenteringanumberintherange0.10(forpolishedchromium)to1.00(forablackbody).Anemissivitylookuptableisprovided,whichliststheemissivitiesofarangeofcommonmaterials.

19SKF TKTI 20

Itisnotrecommendedthattemperaturemeasurementsbeattemptedwhenemissivityvalueslowerthan0.70arerequired,becauselargeerrorsarelikelyduetoreflectedradiationfromsurroundingobjects.

Setemissivityvaluebetween0.10and1.00formeasuringtemperature.Werecommendausualvalueof0.95.Emissivitycanbechangedafterwardinthesavedpicture.

PressingDirectaccessbutton3(εTable)givesatableofemissivityvaluesofcommonmaterialsfromwhichaselectioncanbemade.Ifmorethanonecursorisselected,itispossibletosetadifferentemissivityforeachcursorbypressingDirectaccessbutton3(Cursorε),pressingthesamebuttonagainwillgiveaccesstotheemissivitytable.

Palette (8 options)

Differentcolourpalettesareusefulinviewingobjectsandscenesfordifferentrequirements.Asasimpleruleofthumb,paletteswithalotofdifferentcoloursaremorehelpfulwhenlookingforhotspotsorcoldspots,whereaspaletteswithfewerandgraduallychangingcoloursaremoreusefulinviewingchangesoftemperaturesinasceneorobject.Werecommendthatyoufindthepalettewhichsuitsyoubest.ItispossibletochangethepaletteonthePCsoftware.

1 2 3 4 5 6 7 8

1. White Hot Mono2. Ironbow3. Rainbow4. Isotherm Style

5. Hot Metal6. High Contrast7. 16 step Rainbow8. Black Hot Mono

20 SKF TKTI 20

Reflected TemperatureThis is only applicable if an emissivity of less than 1 is selected.

Someoftheinfraredenergyseenbythecamerafromasurfacewithanemissivityoflessthan1.00isenergyreflectedbythebackground.Ifthereisahotobjectinthebackground,thiscanhaveasignificanteffectonthetemperaturemeasured.Byenteringareflectedtemperaturevalue,thecameracancorrectfortheeffectofthisreflectedbackgroundenergy.Usuallysettotheambienttemperature.

Temperature unitsChoosebetween˚Cand˚F.

Integration. (1 low to 4 high.)Thecameranormallyoperatesataframerateof8Hz(i.e.theimageisupdated8timespersecond).Forviewingscenesinwhichthereisverylittletemperaturevariation,theimagemaybeimprovedbyintegratingoverseveralframestoreducethenoise.

Chooseanintegrationperiodfrom1(fast)to9(slow).Howeveritisrecommendedtokeepthevalueat1fornormaluse,highervaluescanbeusedwhenthecameraisheldsteadilyorfixedonatripod.

Interpolation. (On/Off.)Interpolationisonbydefaultasitsmoothestheimagetoprovideabettervisualimage.Turningitoffgivesamorepixelatedimage.Someusersmaywishtoobservethescenewiththeactualresolutionofthedetector.Theprocessorcalculatesthetemperatureofsub-pixelsandthereforedisplaysmorepixelsonthescreen.Thissettingdoesn’tchangeanythingtothetemperaturemeasurement.Actualresolutionis160x120.Byturninginterpolationontheresolutionisinterpolatedto320x240.

21SKF TKTI 20

4.4.2 Menu Measurement Options

Thismenuenablestheselectionofoptionsfortemperaturemeasurements.ThesymbolsshownbelowindicatetheiconsshownforDirectaccessbutton1whenthevariousoptionsareselected.

Cursors

Uptofourmeasurementcursorscanbeselected.Whentwocursorsarechosen,thetemperaturesofbothcursorsandthetemperaturedifferencebetweenthemwillbedisplayed.WhenoneofthecursorsisselectedbyDirectaccessbutton1,itcanbemovedaroundonthedisplaybythenavigationbuttons.Iftwoormorecursorsareselectedthenindividualemissivityvaluescanbeassignedtoeachcursor.Whenanemissivitylessthan1.00isselectedforacursor,thenthatcursorflashesonthescreen.Theemissivityofcursor1isalwaysdisplayed.

Four tabular cursors Three tagged cursors

22 SKF TKTI 20

Tracking

Select“High”,“Low”,or“High&Low”inordertotrackandmeasurethefollowing:• thehottestpartofthescene• thecoldestpartofthescene• boththehottestandcoldestpartofthescene.

Cursors temperature Cursor temperature difference

Tracking hot in red and cold in blue

Area

Areaanalysisisusefulwhenwantingtoknowthehighestandlowesttemperatureinapartofthescene.Italsoshowstheaveragetemperature.Therearethreeboxsizestochoosefrom.

Maximal temperature Minimal temperature Average temperature

Area analysis

23SKF TKTI 20

Isotherms

Select“High”,“Low”,or“High&Low”inordertohighlightareasofthescenewithtemperatureswithinahigh(red)orlow(blue)temperatureband.Thetemperaturebandsareadjustablebymeansofdirectaccessbutton1andthenavigationkeys.Useleft/rightnavigationbuttontosetthespanandupanddownnavigationbuttontosettheleveloftheisotherm.

Red isotherm Blue isotherm Combined isotherms

Temperature profiles

Select“Horizontal”or“Vertical”toenableahistogramoftemperaturevaluesalongahorizontalorverticalcrosssectiontobedisplayedontherighthandsideorthebottomofthedisplay.ThepositionofthecrosssectionisindicatedbysmallarrowsattheleftandrightortopandbottomoftheimageandcanbeadjustedbymeansofHotkey1andthenavigationbuttons.

Vertical profile Horizontal profile

24 SKF TKTI 20

Temperature alarms

Select“High”,“Low”,or“High&Low”.Visualandaudio(ifenabledinAudiosettingmenu)alarmswillbetriggeredifeithercursororapointwithinthedesignatedareaishigherorlowerthanasettemperature.ThehighandlowsettemperaturesmaybeadjustedbymeansofDirectaccessbutton1andthenavigationbuttons.

4.4.3 Menu Camera Settings

CaptionModeSelect“On”toenabletheadditionofatextcaptionwhensavinganimage.Optionswillthenbedisplayedwhensavinganimage,tobeselectedbymeansofHotkey2andHotkey3.

Auto OffSelect“5Mins”,“10Mins”,“20Mins”toallowthecameratoswitchitselfoffafteradefinedperiodofinactivityinordertosavepower.AlwaysonmeansthattheAutoofffunctionisdisabled.

Camera ResetSelectDirectaccessbutton3torestorethefactorysettings.

Sequence recordThisoptionallowstheusertosaveimagestothemicroSDcard.Whensequencerecordingisselected,itispossibletosaveimagesevery05seconds,10seconds,20seconds,30seconds,1minute,2minutes,5minutes,10minutes,20minutes,30minutesand1hour.Thealarmsettingworksinconjunctionwiththetemperaturealarmfunction.Whenthetemperatureinthesceneexceedstheuserdefinedhighalarmthresholdtemperatureanimageissaved.Equallywhenthetemperatureinthescenegoesbelowtheuserdefinedlowalarmthresholdtemperatureanimageissaved.

25SKF TKTI 20

Sequences CapturesOncesequencerecordhasbeenselectedtheusercanchoosehowmanyimagestosavefromachoiceof:10,50,100,500or1000.

4.4.4 Menu Audio Settings

Imager SoundsSelect“Off”tomuteallsounds.

Voice AnnotationSelect“Session”toaddavoicemessageatthestartofasetofimages(Asessionendswhentheimagerisswitchedoff).Select“Individual”toaddavoicemessagetoeachsavedimage.Select“Combined”toaddacommonvoicemessageatthestartofasetofimagesandaddadditionalcommentsforeachimage.Ifsessionorcombinedisselected,thevoicemessageisrecordedintheaudiosettingsbypressingDirectaccessbutton3.RecordingisstoppedbypressingDirectaccessbutton3again.Directaccessbutton2canbeusedtoplaybacktherecordedmessage.Directaccessbutton3canbeusedtore-recordifnecessary.

Voice PlaybackSelect“Speaker”or“Headset”forthedesiredmethodofaudibleoutputs.

VolumeSelectthevolumeoftheaudibleoutputsfrom1to9.

26 SKF TKTI 20

4.4.5 Menu Image Browser

Thesavedimagesareshownonthescreenwiththemostrecentlysavedimagefirst.

Selectthedesiredimagebymeansofthenavigationkeys.TodisplaytheselectedimagepressDirectaccessbutton3.TodeletetheselectedimagepressDirectaccessbutton2,toconfirmdeletionpressDirectaccessbutton3.

Whenastoredimageisdisplayed,pressDirectaccessbutton3toreturntoliveimaging.

27SKF TKTI 20

4.4.6 Menu Date & Time Settings

a) Usetheleft/rightbuttonstonavigateinthismenu,theitemthatcanbechangedishighlightedinred.Inthepictureabovetheday(DD)14ishighlighted.

Thedatedisplayedformatcanbechangedbypressingdirectaccesskeynumber2

b) Usetheup/downbuttonstochangethevalue.

• Minute.(00to59.)• Hour.(00to23in24hourformat,amorpmin12hourformat.)• 12houror24hourclock.• Day.(01to31.)• Month.(01to12.)• Year.(2000to2099.)• Format(DD-MM-YYYY,MM-DD-YYYY,YYYY-MM-DD).

4.4.7 Menu Language Selection

Inthismenuyoucanselectthelanguageinwhichyouwanttousethecamera.

28 SKF TKTI 20

Theiconwithayellowbordershowstheselectedlanguage.

PressDirectaccessbutton3toselect.

Languages

French Korean

German Japanese

Italian Turkish

Spanish Russian

Portuguese Czech

Chinese

29SKF TKTI 20

4.4.8 Menu Display Settings

LCD brightnessSelectfrom1(low)to9(high)tocontrolthescreenbrightness.Alowsettingwillcontributetosavebatterylife

ZoomAllowstheusertodigitallyzoomintotheimage.OptionsareX1,X2andX4zoom.

Cursor TypeChoosetodisplayatabularCursororatagnexttothecursor.

εChoosewhetherornottodisplaythereflectedtemperature.Onlyapplicablewhenemissivityisselectedtobelessthan1.

Temp. Units.Choosewhetherornotthetemperatureunits(°Cor°F)aredisplayedonthescreen.

Colour ScaleChoosewhetherornotthecolourscaleistobedisplayed.

Icon TimeoutTheIconsabovethe4directaccesskeyscanbedisplayedeithercontinuouslyorfor10secondsafterthelastkeyispressed.

30 SKF TKTI 20

5. Saving and annotating pictures

5.1 Saving a picture

Tosaveapicturepressthesavebutton(seefigure6).Afterpressingyoucanadd‘voicemessage’and‘caption’tothepicture.Note:microSDcardshouldbeinsertedforsavingapicture(seefigure2).

5.2 Adding a voice message

WhensavinganimagewithIndividualVoiceAnnotationturnedon(see4.4.4).Thereyoucansaveavoicemessagewitheachimage.Thevoicerecordingcanbeplayedbackwhenviewingthesavedimagesinthebrowser(seechapter4.4.5).

a) YoucanattachavoicemessagetothissavedimagePressDirectaccessbutton2forno.PressDirectaccessbutton3foryes.PressDirectaccessbutton4tocancelandreturnto‘live’

b) Startvoicerecording?

PressDirectaccessbutton3foryes.PressDirectaccessbutton4tocancelandreturnto‘live’

c) StopRecording

PressDirectaccessbutton3tostop.PressDirectaccessbutton4tocancelandreturnto‘live’

d) OptiontoRe-recordthevoicemessagePressDirectaccessbutton1forreplayingyourvoicemessagePressDirectaccessbutton2forYesPressDirectaccessbutton3forNoPressDirectaccessbutton4tocancelandreturnto‘live’

31SKF TKTI 20

5.3 Adding a Caption

WhensavinganimagewithCaptionModeturnedon(see4.4.3),youcanattachatextcaptiontoeachimage.

a) YoucanattachavoicemessagetothissavedimagePressDirectaccessbutton2forno.PressDirectaccessbutton3foryes.PressDirectaccessbutton4tocancelandreturnto‘live’

1. Usetheup/downarrowbuttonstocyclethroughlettersandnumbersuntiltheonerequiredappears.Theavailablesymbolsare:ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789

2. Usetheleft/rightarrowbuttonstomovetothenextspaceandrepeattheabovestepuntilthecaptioniscompleted.

3. PressDirectaccessbutton2toclearthewholemessage.

4. PressDirectaccessbutton3tosavetheimageandcaption

Note: Captionscannotbeviewedwiththesavedimagesinthebrowser.ThecaptionscanbeviewedusingthePCsoftware(formoredetailedinformationseeIFUTKTI20ThermalCameraSuiteSoftware(MP5386)).

Imagewithvoicemessageisbeingsaved.

Boththermalandvisibleimagesarenowsavedwithannotationsandcaptionifrecorded.

32 SKF TKTI 20

6. Technical specifications

Performance

Fieldofview(FOV) 20ºx15º

SpectralResponse 8to14µm

Sensitivity NETD≤80mK(0,08ºC)@23ºCambientand30°Cscenetemperature

Detector 160x120pixelarray(interpolatedto320x240)uncooledmicrobolometer

Framerate 8Hz

FocalRange Manualfocusfrom0,3m(12in)toinfinity

Image Storage

Number Upto2500imageson2GBmemorycardsupplied

Medium MicroSDCard

Display 31⁄2”colourLCDwithLEDBacklight.8colourpalettes.Thermalimagesorvisibleimagesormixedthermalandvisibleimagesincludingpictureinpicture.

LaserPointer AbuiltinClass2laserissuppliedtohighlightthereferencepixel

Measurement

Temperaturerange -10ºCto+250ºC(+14ºFto+482ºF)

Radiometry Fourmoveabletemperaturemeasurementcursorsgivingautomatictemperaturedifferencemeasurementandautolockingontohottestandcoldestpoints

EmissivityCorrection Userselectable0,1to1,0instepsof0,01withreflectedambienttemperaturecompensation.Thefourmeasurementcursorscanhaveindividualemissivityvaluesassignedtothem.

Accuracy Thegreaterof±2°Cor±2%ofreadingin°Cfortheoperatingtemperaturerangeof-15°Cto+45°C.

33SKF TKTI 20

Camera Power Supply

Battery RechargeableLithium-Ionfieldreplaceable

Operationtime Upto5hourscontinuousoperation

ACoperation USBACpoweradaptorsupplied

Mechanical & Environment

Housing ImpactResistantPlasticwithover-mouldedsoftplastic

Dimensions 130x95x220mm(5.1x3.74x8.66in)

Weight 0.80kg(1.76lbs)

Temperatureoperating&storageRange

-15°Cto50°C(5°Fto122°F)

Humidity 10%to90%noncondensing/-20°Cto70°C(-4°Fto158°F)

IPrating IP54

Software SKFTKTI20ThermalCameraSuite:Advancedimageranalysisandreportwritingsoftware

ComputerRequirements

PCwithoneofthefollowingoperatingsystems:WindowsXP,VISTA,orWindows7

34 SKF TKTI 20

35SKF TKTI 20

SKF Maintenance Products

The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of use of the information contained herein.

www.mapro.skf.comwww.skf.com/mount

MP5385EN

® SKF is a registered trademark of the SKF Group. © SKF Group 2011/04