Simplifying Data Center Design/Build
A new approach to deliver speed, cost, and performance (availability, efficiency, scalability)
2
Your ability to compete relies on the design, build, and operation of your data center
Whether you are an Enterprise or in the data center business
33
Trends
4
The Internet of Everything is driving the need for large amounts of computing power, bandwidth and storage
Source: Cisco IBSG, April 2011
Number ofconnections
Number ofmeaningful interactions
It would take you 5 years to view the video crossing IP networks each second
It would take you 5 years to view the video crossing IP networks each second
55
IT Trends
Social technologies
Servers without UPSCloud
computing
Energy consciousness
Lower tiers Mobile devices
Converged IT Prefabricated modular data centers
New cooling techniques
Relaxed operating standards
ColocationRising security concerns
6
The move to Cloud Computing is reinforcing the need for speed, cost, and performance
Promises made by cloud providers
>lower costs
>more modularity and portability
>instant scalability and capacity
>greater application flexibility and portability
7
Room for improvement in performance, cost, and speed
In today’s traditional Design/Bid/Build processes
1. Long design time leading up to construction documents
2. Multiple design and/or equipment changes drive up cost and construction time
3. Multiple vendor management
4. Multiple markups driving higher overall cost
5. Coordination and integration challenges increasing both cost and construction time
Top 5 Weaknesses
Lower Performance
HigherCost
SlowerSpeed
88
How Schneider Electric Can Work With You
9
We provide the supply model you prefer
Complex Data Center systems that are key pieces of Data Center domains – IT Room, Facility Power, Facility Cooling, Security, DCIM
SubsystemsInnovative combination of technology, products, and services providing an integrated, high value response to Data Center customer needs
Solutions100,000+ catalog of Data Center components and individual software modules
Components
10
We can work with you in many ways
To solve your business challenges
TurnkeyProvider
Trusted Advisor
Facility Operator
DCIM Integrator
TurnkeyProvider
Trusted Advisor
Facility Operator
DCIM Integrator
Power Quality Software SupplierPower Quality Software Supplier
Switchgear SupplierSwitchgear Supplier
Building Operations Software SupplierBuilding Operations Software Supplier
UPS SupplierUPS Supplier
IT Room Management Supplier
IT Room Management Supplier
IT Rack SupplierIT Rack Supplier
Remote Monitoring Provider
Remote Monitoring Provider
UPS Maintenance Provider
UPS Maintenance Provider
Software InstallerSoftware Installer
Arc-flash AssessorArc-flash Assessor
Project ManagerProject Manager
Design AssistantDesign Assistant
SolutionsSolutions
Hardware & SoftwareHardware & Software Services Services
1111
Schneider Electric Approach
12
The Schneider Electric approach is to dramatically SIMPLIFY the process in order to improve performance, cost, and speed
>Services for the life cycle
>Broad offer
>DCIM Software
>Prefabrication – modular standardization
>Tools and Reference designs
1313
Services for the life cycle
14
Schneider Electric as a Data Center service provider
Can support all projects> Small and large
> New and retrofit
Offer complete range of life cycle services
On-site and off-site support> Depth and bench
strength
Minimize risks, expenses, and timeframe
Toolsets with standardized record keeping> History
> Data access
> Entitlements
Processes are documented and mature
Clear escalation paths Globally consistent standards,
offer, coverage, and support Simplified experience means a
“one-stop-shop” for managing all physical infrastructure service needs
Service personnel are trained and certified
Considered to be industry and subject matter experts
Leverage experience to implement and improve best practices
Can attain “Trusted Advisor” status
15
Holistic service…
One company to assess, plan, design, manufacture/build and operate your data center....to improve performance, cost, and speed
16
Schneider’s design/build capabilities NAM...
Focused exclusively on data centers
Perform site evaluations, assessments and capacity planning – IT Room, Power, Cooling, DCIM, Security, Safety
Fully licensed engineering and construction
Able to plan, design, estimate, construct and manage turn-key data center projects
Fixed price, Owner’s agent, CM (contract manufacturer) – flexible delivery methods
Competitive advantage: best in industry $$/kW and fastest delivery
17
Schneider is now a Design/Build firm specializing in simplifying the delivery of data center solutions
Relationship & Accountability
Long-term partner for performance
Global Supply Chain
Single point of accountability
Turn-key solution provider
Competitive delivery $$/kW
Improved Speed-to-Market
18
Maintenance coverage includes simple maintenance to full operations and
optimization services
Maintenance Services
ONE Data Center Contract
Multi-Vendor Maintenance
Managed Services
SE UPS & Cooling
SE UPS, Cooling, ED, Security
All vendor UPS, Cooling, ED, Security
Scheduling, Resources on-site
On-Site DataCenter Operations
Attached
HighlyConsultative
Operations
19
Facility Operation…simple designs and improved controls reduce operational risk and complexity
Emergency Preparation
Maintenance Management
Facility Optimization
Reporting & Analysis
Crisis Planning
Crisis Management
Incident Management
Safety Program
Vendor Management
Maintenance Programs
Energy Management
Reliability Engineering
Space Planning
Regulatory Compliance
Audit Compliance
Capacity Planning
20
With the largest team of expertsSchneider Electric is here for you
With over 7,000 service experts including
>Technicians
>Program managers
>Support staff
>Solution Architects
And a dedicated service supply chain
2121
Broad Offer
22
Modular UPSModular PDU
Rack PDU
Security and Environmental Busway
Rack Systems
Room/Rack/RowCooling
Cable Management
Flexible Air Containment
Row Modular UPS
MV Switchgear
LV Switchgear
LV Panelboards & Switchboards
MV Transformers
Cooling - VSD
Meters
Lighting ControlResource Advisor
Data Center Operation
Building Operation
Power and Data Center Expert
Schneider Electric Data Center Solutions RACK to ROW to ROOM to BUILDING RACK to ROW to ROOM to BUILDING
2323
DCIM Software
24
Data Center Expert
Resource Advisor
Cooling Monitoring ExpertMonitor and control data center cooling
Power Monitoring ExpertAdvanced power monitoring and power quality analysis
Data Center Operation
Manage Data Center assets, operational and capital costs
Advanced monitoring and automation
Track and manage enterprise energy and carbon costs
Comprehensive DCIMComprehensive DCIM
25
StruxureWare Expert software monitors and manages power, cooling and security
Data Center Expert
•PDU’s, RPP’s
•RM PDU’s, Environmental
•Busway, Security
•Panelboards
•UPS
•Security
Power Monitoring Expert
•Switchgear MV & LV
•Metered Breakers & Panelboards, PDU’s, RPP’s
•Busway, Transformers, UPS
•Generators and ATS
26
We make it easy to manage all of your data center assets and operational costs
Data Center Operation● Improved electrical and operational efficiency
● View of overall energy asset utilization to better plan for growth and dynamic change
2727
PrefabricationModular Standardization
28
Data Center components that Schneider Electric offers as prefabricated functional building blocks
Power
Cooling
IT
29
We have introduced a broad offer of prefabricated data center modules
> 90kW All-in-One
> 110kW Single Module
> 205kW Single Module
> 240kW Dual Module
> 250-1.2MW Hydronics Modules
> 250kW – 1.2 MW Packaged Chillers
> Ecobreeze Air Economizer
> 250kW – 500 KW Enclosures
> 1.2 MW Skid Mounted
IT Room Modules Cooling Modules Power Modules
30
Prefabricated Data CentersPerformance, cost, and speed advantages vs. traditional Data Centers
Predictable Performance> The density, availability, and efficiency
you expected
> The cost you were promised
> Project timing as you planned
Faster Deployment> Less decisions necessary for
planning and design
> Up to 60% less time for deployment
> Delivery in 12 weeks or less: PO to ship
Flexibility and Scalability> Defer capital expenses and
maximize cash flow
> Adjust for changing requirements
> Deploy in various configurations of density and availability
31
StruxureWare DCIM Fully instrumented and programmed in each Building Block
32
StruxureWare DCIM dashboard compatibility
33
Modular scalable deployments improve the use of your capital
Power & Cooling
IT Pods
Cooling
PowerCooling
IT
3434
Tools and Reference Designs
35
Our tools and designs are the best around
Customer Access to White Papers, TradeOff Tools, and Education
Library of Complete Data Center Reference Designs from 200 kW to 20MW
White Papers Education
Reference Designs
36
Industry collaboration and “open source” is gaining momentum
With the goal of standardizing components, architectures, and processes
Challenge convention by custom designing servers and data centers from the ground up – and then share these technologies as they evolve
Schneider Electric is the Project Chair for Data Center Design
Challenge convention by custom designing servers and data centers from the ground up – and then share these technologies as they evolve
Schneider Electric is the Project Chair for Data Center Design
Open industry consortium to create a common set of metrics, and develop technical resources and educational tools
Schneider Electric is a founding member and President of The Green Grid
Open industry consortium to create a common set of metrics, and develop technical resources and educational tools
Schneider Electric is a founding member and President of The Green Grid
HP, AMD, VMWare, IBM, Seagate, Facebook, Microsoft, Intel, Schneider Electric and many more
37
Data Center Reference Designs
> Library of engineered reference
designs
> 1, 2, 3.3 and 20 MW deployment
sizes
> Uptime Tier II and III designs
> Design Methodology and Explanation
> System level technical specifications
> Available load, PUE, Density, Layout
> Complete schematics and BOMs
38
Reference Design Options
Semi-Prefabricated Data Center
A Data Center comprised of building blocks
and traditional “stick built”
Fully Prefabricated Data CenterA Data Center comprised completely of
prefabricated IT, Power, and Cooling modules
Could be outside or in a building/warehouse
Traditional “Stick Built” Data Center
39
Schneider Electric traditional “stick built”
> Fully Engineered Design
> 1 MW Tier III
> 140 racks at 6.5 kW/rack
> 2N 1200 kW UPS
> 2N 1200 kW Chillers
> 1000 kW Hydronics Modules
– Calculated PUE = 1.40
– 10-12 Month Greenfield Delivery
– Competitive cost
Reference Design #9
http://designportal.apc.com/dcrd/resources/pdf/en/RD9DSR0.pdf
40
Schneider Electric traditional “fully prefabricated”
> Fully Engineered Design with
prefabricated Power, Cooling and IT
> 2 MW Tier III
– 176 racks at 10 kW/rack
– 2N 1200kW Power Skids
– 2N 3X500 kW Chillers
> 2X1000 kW Hydronics Modules
– Calculated PUE = 1.39
– 12-16 Week Greenfield Delivery
– Competitive cost
Reference Design #36
http://designportal.apc.com/dcrd/resources/pdf/en/RD36DSR0.pdf
41
Customer focused experts
Worldwide teams of experts…>Planning and Design experts>Data Center Solution Architects>Project Managers>Strategic Partners>Solution Centers
Leveraging teamwork to support you
42
Schneider Electric has simplified design and build to improve speed, cost and performance
(availability, efficiency, scalability)
We are streamlining Plan and Design phases with Reference Designs
We are simplifying Design and Build process with prefabricated Data Centers
We employ a worldwide team of Design and Build experts
top related