© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 1
SAN DeviceVirtualization
Commands hidden in NX-OS 5.x as feature has been deprecated after NX-OS 4.x
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 2
About SAN Device Virtualization (SDV)
What is SAN Device Virtualization? Virtualization of Initiators/Targets
– Target Migration = Migrating from one target (Primary Target) to another (Secondary Target) for one or more initiators (servers).
– Server Migration = Migrating from one initiator to another for one or more targets (disk).
Main Focus of presentation on Target Migration, but applies to Server Migration also.
What is driving the need for Target Virtualization functionality?
–Target failures: hardware, logical corruption
–Data migration: technology refresh, workload balancing, storage consolidation
–Virtualization Ready: for future needs
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 3
About SDV continued
What are the benefits of the feature compared to manual migration?
– Reduce the amount of time for migration; hence reducing the downtime
– Ease of management; Reduces possibility of human errors.
– Easily scalable for larger number of initiators/targets.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 4
Today's Deployment for Handling Target Failures
Designed for HA; Redundancy is the key.
Deploy two arrays: primary & secondary.
Use some type consistency technology such as EMC SRDF between primary and secondary to ensure that secondary is a mirrored copy of the production LUN.
When primary fails, manually bring secondary online. All I/O will now take place with the secondary.
–The time required to `use’ secondary is the problem.
SAN
Primary Target
Secondary Target
ASYNCReplication
I/O - Normal
I/O - After Primary Failure
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 5
The Challenges of Handling Target Failures The time required to make secondary target accessible can be quite
long. This impacts the application availability.– For a typical production environment of 2 clustered hosts, and a database size of
2TB, this takes over 4 hours.
This down-time consists of two components:
- Zoning Changes• All the initiators now have to be re-zoned with the Secondary Target
- Re-configuring certain initiators
• Since WWN and FCID of the secondary is different, some driver files have to be changed and server rebooted, which adds risk (Eg: HP-UX and AIX servers)
• Clustering (multiple initiators) compounds the problem; Procedure has to be repeated for each server of the cluster.
Primary Array fails
Zoning Changes Changes to InitiatorsSecondary Array online
Up to a couple of hours
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 6
The SDV Manager SDV is a conditional service running on the MDS Switch Supervisor
that can create virtualized devices.
SDV presents a Virtual (Proxy) target to initiator.– Initiators are presented with a Virtual Device (VD); the virtualized form of the real target.
– VD is created by configuration and is identified by a name.
– VD virtualizes a single real target at any point of time.
– VD registered with Name Server with a pWWN and consumes an FCID outside of the real domain.
– VD is ‘hosted’ by one of the switches in the fabric.
– Administrators Zones VD with (real) initiators using regular Zoning Config. Initiator can be a VD also.
– Initiators discover VD through NS queries.
– The initiators always perform SCSI I/O operation to the virtual address of the VD.
–At this point, either the initiator or target can be VD, but not both.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 7
SDV Manager Contd..
SDV performs FCID translations on the frames destined to VD.
– In the forward direction, DID is rewritten to that of the real target.
– In the reverse direction, SID is rewritten to that of the VD.
The VD is hosted by one of the switches using a virtual domain.
The VD has an FCID and pWWN/nWWN assigned by the switch.
VD exists as long as its real counterpart is online. It inherits the FC-4 type and features from its real counterpart.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 8
SDV Solution: The Big Picture
Configure a Virtual Target (VD) on MDS. Initiator is zoned with VD. VD is linked to a real (Primary) Target. For control traffic (PLOGI, PRLI etc.)
– MDS provides proxy functions. That is, it receives these ELS frames and re-transmits it to the real Target by performing NAT in header and payload.
For data traffic– MDS provides NAT of header VD FCID in
hardware
The Primary and Secondary Targets can be on different MDS switches.
This features can be enabled on MDS without requiring a change on servers and storage arrays.
The admin can perform the Target Migration from primary to secondary through a single step configuration.
Primary Target Secondary Target
WWN2 FCID2
WWN3FCID3
WWN1 FCID1
WWN4 FCID4
Virtual Target
Initiator
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 9
Logical Zones
• The {initiator, VD} is zoned. However the real target is not part of any zone. Hence according to zoning the reverse path frames from target to initiator would be dropped.
• To overcome this restriction a logical zone is created with {initiator, target} and Zone Server is notified.
• The purpose of this logical zone is to make sure that w.r.t. the targets it is zoned with the initiators, but w.r.t. the initiators they are not zoned with the target.
• The logical zone is not present physically in the active ZoneSet. Hence presence of this zone not known to others.
• Logical Zones known only to SDV switches. Hence solution is limited to those devices that are directly connected to SDV enabled switch.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 10
Solution Step 1: Creating the VD
Primary Secondary
t1pwwn t1
t2pwwn t2
i1pwwni1
Virtual Target
VT
i2pwwni2
i3pwwni3
SDV
A VD defined by user configuration enumerating all the targets (primary and secondary)
When a VD is created• SDV picks a unique pwwn for the VD.• Registers the VD name with its pwwn as an Device Alias.
vtpwwnvt1
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 11
Solution Step 2: Zoning VD with Initiators
Primary Secondary
t1pwwn t1
t2pwwn t2
i1pwwni1
Virtual Device
vtpwwnvt1
i2pwwni2
i3pwwni3
When VD name is zoned with initiators and activated …
• SDV assigns FCID for VD.• SDV Registers VD with NS and sends SW-RSCN for VD once the primary target is online.• Inform ZS about presence of Logical Zone (dotted in the diagram).
SDV
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 12
Solution Step 3: Linking VD with target
Primary Secondary
t1pwwn t1
t2pwwn t2
i1pwwni1
Virtual Device
vtpwwnvt1
i2pwwni2
i3pwwni3
SDV
When VD is linked with real target
• ACL Rewrite entries are programmed to do the header NAT of data frames on access ports.• ACL Capture entries are programmed for payload NAT of Control frames (ELS) by the SUP.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 13
Hosting the VD• Hosting involves injecting the virtual entities (VD) into the fabric.
• Hosting done by one switch; But it cannot use its local domain for the VD FCID because if this switch leaves the fabric OR the local domain changes, FCID would have to change.
• The hosting switch reserves a Virtual Domain used for assigning to VD. If the hosting switch goes down another switch could take over its role using the same virtual domain.
• Virtual Domain reservation to be used for the VD is through Domain Manager using the RDI mechanism.
• The route for virtual domain is advertised by hosting switch through FSPF.
• Hosting consists of: FCID allocation, NS registration, SW-RSCN generation, Injecting Zones and route advertisement.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 14
Rewrite Entries & ELS Capture entries
• Rewrite entries are programmed in ACL TCAM for FC header fcid-rewrite of the data traffic.
• For each <initiator,target> pair two rewrite entries are needed. One in the forward direction and one in the reverse direction.• Each ACL Rewrite entry includes zoning, forwarding and rewrite information and avoids using FIB lookup/adjacency. The rewrite entry would overwrite the zoning entry.
• ELS capture entries are programmed for FC payload fcid rewrite of the control traffic.
• All the ELS frames to VD are punted to Supervisor.• The SDV module running on Sup does payload fcid-rewrite depending on the ELS type and forwards it on the egress interface.• Some of the ACC frames also need payload fcid-rewrite.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 15
Frame translation with rewrite entries
t1pwwn t1
i1pwwni1
i1 vt1
i1 t1 t1 i1
vt1 i1
S_ID D_ID
ACL entries
Frame values Rewrite valuesS_ID D_ID S_ID D_ID
i1 vt1 i1 t1 i2 vt1 i2 t1 ………. t1 i1 vt1 i1 t1 i2 vt1 i2
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 16
Header and Payload rewrites
PLOGI trapped and punted to supervisor for payload FCID rewrite
Supervisor forwards frame to egress line card for header FCID rewrite
SCSI commands are forwarded to egress line card for FCID header rewrite
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 17
Configuration Enable the feature
(config)# sdv enable Create a VD
(config)# sdv virtual-device name disk vsan 1
(config-sdv-virt-dev)# pwwn 21:00:00:20:37:a9:d7:42 primary Zone VD with desired devices
(config)# zone name zone1 vsan 1
(config-zone)# member pwwn <initiator> (config-zone)# member pwwn <VD-pwwn assigned by MDS>
Activate ZoneSet (regular zoneset activation)
(config)# zoneset activate name <zs> vsan <> Link with current primary real target
(config-sdv-virt-dev)# link pwwn 21:00:00:20:37:a9:d7:42
(Use the same ‘link’ command to switch to secondary target if primary goes down)
(config-sdv-virt-dev)# link pwwn 22:00:00:20:37:a9:d7:42 Different pwwn that exposes
same luns
Real target PWWN
Device-Alias created with this name automatically
Real initiator PWWN
PWWN assigned by MDS to represent
target to host
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 18
Domain, FCID, and PWWN used for VDswitch# show sdv virtual-device name diskvirtual-device name disk vsan 1[ WWN:50:00:53:00:00:cd:c0:01 FCID:0x140654 Real-FCID:0x7c03e4 ] pwwn 21:00:00:20:37:a9:d7:42 primary
PWWN assigned by MDS. Use this for zoning with
real initiator
FCID used to represent the
real target
RTP9-CAE-POD2-9509# sh fcdomain domain-list
VSAN 1Number of domains: 2Domain ID WWN--------- -----------------------0x64(100) 20:01:00:05:30:00:49:1f [Local] [Principal]0x14(20) 50:00:53:07:ff:f0:00:71 [Virtual (SDM)]
Domain used to represent DID for the Virtual Devices hosted by this switch for this VSAN
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 19
Locking down the domain and FCID used for the VD
The hosting switch will reserve a DID for the VDs
It can not be the same DID assigned to the VSAN in the event that another switch has to assume the hosting of the VD.
switch(config-sdv-virt-dev)# ?Configure a Virtual-device: device-alias Add a device-alias to the Virtual-device do EXEC command end Exit from configure mode exit Exit from this submode link Link the Virtual-device to a real device no Negate a command or set its defaults pwwn Add a pwwn to the Virtual-device virtual-domain Configure the persistent virtual domain virtual-fcid Configure the persistent virtual fcid
sdv enablesdv virtual-device name disk1 vsan 1 virtual-domain 138 virtual-fcid 0x8a197f pwwn 21:00:00:04:cf:17:66:b7 primarysdv commit vsan 1
Configured under virtual device
Completed
Configuration
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 20
Multi-switch Fabric
Primary Secondary
I1 I2
SW1SW2
SW3
T1 T2
VD
• SVD enabled on one of the switches that acts as the hosting switch. Eg: SW1 is the hosting switch
• The frame rewrite has to happen only on this hosting switch. Eg: Even though the traffic between I2 and T1 need not go thru SW1, it goes thru SW1 (because of VD’s fcid)
• Drawback: Does not work if any switch in path from initiator to target is not SDV enabled. (logical zone unaware) • Other Drawbacks: - The hosting switch is the single point of failure. - Hosting switch failure recovery requires manual intervention. - Non optimal routing of data frames.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 21
Comparison with IVR-NAT SDV IVR-NAT
Injects virtual devices in a VSAN for transparent migration so that initiators can communicate with a virtualized target.
Injects virtual devices in all the VSANs in the path from initiator to target, so that initiators communicate with targets across VSANs.
Scope within a VSAN. Scope across VSANs.
Does frame S_ID and D_ID rewrite. Does frame VSAN, S_ID and D_ID rewrite.
The VD created by user configuration.
All the Virtual devices required are created automatically.
Uses one virtual domain for all VDs in a VSAN.
Can use multiple virtual domains for virtual devices in a VSAN.
Regular Zoning Configuration used.
IVR Zoning Configuration used.
© 2006 Cisco Systems, Inc. All rights reserved. Cisco ConfidentialPresentation_ID 22