A Ty c o I n t e r n a t i o n a l C o m p a n y
www.swhouse.com
Features That Make a Difference:
• Providesreal-timecommunicationbetweenaC•CUREsystemandSchlageAD-Serieselectroniclocks
• ManageavarietyofaccesscontrolfunctionalityfromaC•CUREsystemmonitoringstation
• Configure,view,andupdateAD-SerieselectroniclockobjectsdirectlyfromaC•CUREsysteminterface
• CommunicateswithiSTARandapCdoorcontrollers
• WirelesslocksutilizefourAAbatteries(eightAAoptional)
• Supportsmagneticstripecards(Track2),proximityHID125kHzcards,13.56MHzsmartcards,multi-tech–125kHzprox&13.56MHzsmartcards,andPIVII(FIPS201)cards
• Deliveredinonefullyintegratedpackage:cardreader,electroniclock,request-to-exitsensor,doorpositionswitch,andfourstandardAAbatteries(wirelesslock)
• Providesmonitoredstatuspoints–request-to-exit,doorpositionswitch,PIMcovertamper,lossofcommunications,lowbatterystatus
• FIPS-201compliantlockoptionsavailable
• Secureavarietyofopeningswithcylindricalandmortiselocks,exitdevicetrim,andgateandelevatorkits
• Perfectfordormrooms,elevators,gates,entrancedoors,computerrooms,electricalclosets,offices,andmedicallaboratories
C•CURE Security SolutionsSchlage Electronic Locks Integration
Withopenarchitectureplatforms,bothC•CURE9000securityandeventmanagementsystem,andC•CURE800/8000accesscontrolandsecuritymanagementsystemseamlesslyintegratewithSchlageAD-Serieselectroniclockstoprovidecost-effectiveandscalableaccesscontrolsolutions.SchlageAD-Serieselectroniclocksareavailableinhardwiredandwirelessconfigurationstofitalmostanyenvironment.
YoucanextendthereachofaC•CUREsystembyutilizingtheSchlageAD-Serieselectroniclocksanddevicesforreal-timemonitoringofalarms,audittrails,centralizedlockdown,andinstantaccesscontrolmanagement.Thelockshaveanumberoffeaturesbuiltin,dependingonthelock,whichareconfigurableinthefieldandcanbemonitoredbyaC•CUREsystem.
AD-SeriesElectroniclockscombineallofthecomponentstypicallyfoundaroundthedoor;suchasthecredential
reader,doorpositionswitch,andtherequest-to-exitswitchinoneconvenientdevicetosimplifyinstallation.SincetheSchlageAD-Serieslocksaredesignedtobemodular,theycaneasilybeupgradedinthefuturetomeetyourchangingsecurityandtechnologyrequirements.
AD-SeriesElectroniclocksgiveyouallthebenefitsofahardwiredsystem–withoutthewires.Thatmeansquicker,morecost-effectiveinstallations,andminimaldisruptiontoyourenvironment.Whetherit’sanewconstructionprojectorahistoricbuilding,AD-SerieswirelesssolutionsfromSchlageareperfectwhensecurity,functionality,andcontrolareequallyimportant.
Fornewconstruction,theAD-300hardwiredlocksprovideallofthebenefitsofatraditionalaccesscontrolsolution.Forexistingfacilities,theAD-400wirelesslocksprovidereal-timeaccesscontrolwithoutcostlyandcumbersomewiring.
Take a closer look
AD-300 Series is Perfect for New ConstructionFornewconstruction,theAD-300hardwiredlocksprovideallofthebenefitsofatraditionalaccesscontrolsolution.Infacilitieswherepermissionschangeonaregularbasis,real-timemonitoringisessential,ortherearealargenumberofusersordoors,AD-Serieshardwiredlockscanprovideaperfectbalanceofsecurity,convenience,andfreedom.Ahardwiredsystemgivesyoucentralized,networkedcontrolfromasinglecomputer.Thatmeansyou’reincompletecontrolofyourfacilityandhavetotalpeaceofmind.TheAD-300communicateswiththeiSTARcontrollerviaaRS-485connectionandsupportsupto16hardwiredreaders.ForWiegandorClock&Dataapplications,communicationwiththeiSTARorapCcontrollerisviathePIB300-2Dmoduleandsupportsuptotworeaders.
AD-400 Series Fits Right into an Existing Facility Forexistingfacilities,theAD-400wirelesslocksprovidereal-timeaccesscontrolwithouthavingtorunwirestoeachdooropening.Perfectforhistoricbuildingsandsensitiveareas,theAD-400wirelessnetworkedlocksgiveyouallthebenefitsofahardwiredaccesscontrolsystem–withoutthewires.Thisallowsyoutosecuredoorsthatweretraditionallydifficulttorunwirestointhepast–andincreasethesecuritythroughoutyourfacility.WirelesstransmissionsareAES128-bitencryptedandusea900-928MHzfrequencyrange.
ThePIM400-485isrequiredforcommunicationbetweentheAD-400wirelesslocksandaniSTARorapCcontroller.ThePIM400-485communicatesviaRS-485withtheiSTARcontrollerandsupportsupto16wirelessreaders.ForWiegandorClock&Dataapplications,communicationwiththeiSTARcontrollerisviathePIM400-2Dmoduleandsupportsuptotworeaders.
Easy to ConfigureTheAD-SerieslocksaretreatedlikeanycontrollerbytheC•CUREsystem.Youcanconfigurethesystemusinghighlyintuitivecommontabsanddropdownboxes.LocksandPIMsareassignedtoiSTARcontrollersandareconfiguredviatheiSTARcontrollerconfigurationscreens.Additionally,inputsandoutputsforeachlockandassociatedreaderareconfiguredviathesamededicatedscreen.
Ideal Solution for Highly Sensitive Applications TheSchlageAD-Serieselectroniclocksaredesignedtobemodularandprovidemoreoptionsandmorefunctionalityinthelock.TheC•CUREsystemandAD-SerieslocksintegrationisanidealsolutionforapplicationswhichrequireapprovalbytheU.S.FederalGovernmentunderHSPD-12forFIPS201compliance.Therearetwoversionstochoosefrom:
• AD-401wirelesselectronicintegratedlockwithFIPS201multi-techpluskeypad
• AD-301withmulti-techpluskeypadforuseinU.S.FederalAgencybuildingswhenusingsmartcardtechnology
ThePIB301-2D,aFIPS201-compliantsystemcomponent,ensuresseamlessWiegandcommunicationwithC•CURESecuritySolutions.
Complement Any EnvironmentEachlockhaswarmandcoolfinishpalettesthatcomplementanydécor,popularleverstylesthatwillsuitotherlockingsolutionsthroughoutthebuilding,andmodernblueLEDbacklightingtoenhancetheuserexperience.Fromeasy-to-usefeaturestoanaestheticallypleasingdesign,theAD-Seriesdeliversasolutionthat’sperfectforanyenvironment.
Diagrams
C•CURE Security Solutions/AD-400 or AD-401 Wireless System Utilizing Wiegand /Magnetic Stripe Signal
C•CURE Security Solutions/AD-400 Wireless System Utilizing RS485 Port
C•CURE9000v2.01/C•CURE800/8000V9.4orhigher
LAN
GCM(iSTARPro)
RS485
PIM400-485(upto16PIMsperiSTAR)
AD400WirelessLocks(upto16locksperPIM400-485
Max16locksperiSTAR)
WirelessRangeupto200’inBuildingConstruction,Upto1000’LineofSight
PMB(iSTAReXuptofourRMbuses
total16locks)
900MHz
iSTAReXiSTARProiSTAREdgeapC/8X
Wiegand/MagneticStripeReader
RequesttoExit
Doorposition
Troublesignal
C•CURE9000v2.01/C•CURE800/8000V9.4orhigher
LAN
WirelessRangeupto200’inBuildingConstruction,upto1000’LineofSight
PIM400-TD2orPIM401-TD2
AD400orAD401WirelessLocks(upto2locksperPIM400-TD2/
PIM401-TD2)
900MHz
A Ty c o I n t e r n a t i o n a l C o m p a n y
www.swhouse.com
Thetrademarks,logos,andservicemarksdisplayedonthisdocumentareregisteredintheUnitedStates[orothercountries].AnymisuseofthetrademarksisstrictlyprohibitedandTycoInternationalLtd.Willaggressivelyenforceitsintellectualpropertyrightstothefullestextentofthelaw,includingpursuitofcriminalprosecutionwherevernecessary.AlltrademarksnotownedbyTycoInternationalLtd.arethepropertyoftheirrespectiveowners,andareusedwithpermissionorallowedunderapplicablelaws.
Productofferingsandspecificationsaresubjecttochangewithoutnotice.Actualproductsmayvaryfromphotos.Notallproductsincludeallfeatures.Availabilityvariesbyregion;contactyourregionalsalesmanager.©2011TycoInternationalLtd.anditsrespectivecompanies.Allrightsreserved.SH0204-DS-201108-R01-A4-EN
Related Products Approvals
C•CURE Security Solutions/AD-300 or AD-301 Hardwired System Utilizing Wiegand /Magnetic Stripe Signal
C•CURE Solution/AD-300 Hardwired System Utilizing RS485 Port
AD300orAD301HardwiredLocks(upto2locksperPIB300-2DorPIB-301-2D)
PIB300-2DorPIB301-2D
iSTAReXiSTARProiSTAREdgeapC/8X
Wiegand/MagneticStripeReader
RequesttoExit
Doorposition
Troublesignal
C•CURE9000v2.01orC•CURE800/8000V9.4orhigher
LAN
GCM(iSTARPro)
PMB(iSTAReXuptofourRMbuses
total16locks)
RS485
AD300HardwiredLocks(Max16locksperiSTARdaisy-chained)
C•CURE9000v2.01orC•CURE800/8000V9.4orhigher
LAN
C•CURE9000 iSTARProC•CURE800/8000
iSTAREdge