TRANSCRIPT

Safecom's proven patented DPS Ver 4 & Integrated Power Booster (Patent P)turns existing coax or power cables lines into dynamic super power highways that provide most reliable and economic powering system and network backup.

Safecom Smart Grid technology for powering & backup Cable TV networks.

DPS v4 Power Booster 4G

• Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPS4 draws power from the nearest available source over existing coax or power cable. Utilizing breakthrough AC/AC stabilize technology safecom's DPS4 + Power Booster ensure maximum voltage level – even over long distances.

The concept

What is DPS- Ver 4?

• A two-way RF Pass 1GHZ passive device that “toggle” available power between two distant locations.

• Redirecting power from the "normally" remote powered area, to the area subject to power outage.

• During normal mode of operation, when there is no power outage at either end of the pair, the DPS v4 act as power block to the other side.

DPS ver 4 – the new generation

Previous generations of DPS DPS Ver 4

External Dual power Inserter is needed

Integrated Dual Power inserter. Power Insertion

Limited by cable conductivity and Voltage drop.

Improved - direct connection to Power Booster via one cable. (Plug & Play)

coverage area

Usually at nightLonger service interruption

Minimal service interruption and no need for night installation.

Installation

---Direct Monitoring outputs Via one Cable to Cheetah & Electroline transponders.

Monitoring

Power Booster (patent p)Increasing the powering area covered by power supply.

Power Booster solves the power distribution problem in a CATV network caused by high-resistance and low energy-efficient coax cables or power cables. The unit ensures the optimal voltage levels required in remote locations by fiber nodes, trunk amplifiers, and line extenders overcoming voltage drop along the power or coaxial able.

t t

Vout 84V +/- 6VVin 50-90 Vac 60Hz

Vin 42-66V Vac 60Hz Vout 62V +/- 3V

US Standard

EU Standard

NEW Power Booster – the 4G Transmission

Power Booster 3G New Power Booster 4GExternal Dual power Inserter is needed

Integrated Dual Power inserter.Stand alone unit. RF PASS 1GHZ

Voltage gain 1:32 Voltage gain 1: 1.52 enabling up to double powering distance. coverage area

Zero crossing - Smooth transition between conversion levels.

Zero crossing - Smooth transition between conversion levels. Technology

3 Automatic gears 4 Automatic gears AC/AC transformation gears

400 mA 100 mA (EU model)200 mA (US model) Self current load

Simple connection between DPS Ver 4 & Power Booster.

T T

DPS

DPS DPS

DPS

Typical DPS Power configuration for HFC network .

DPS

DPS DPS

Suggested DPS Power configuration after upgrade to FTTC / FTTB

network . DPS

DPS

DPS DPS

Simulating DPS backup during power failure at

first central location .DPS

DPS

DPS DPS

DPS

Simulating DPS backup during power failure at

second central location .

DPS

DPS

DPS

DPS

Simulating DPS backup during power failure at

third central location .

DPS

DPS DPS

DPS

Simulating DPS backup during power failure at two central locations

simultaneously .

DPS

DPS DPS

DPS

Optional central backup by one

generator.

Simulating DPS + Central Generator backup during power failure at all locations

simultaneously .

DPS

D P S D P S

DPS

DPS

D P S D P S

DPS

DPS

DPSDPS

DPS

DPS

DPSDPS

DPS

Low Voltage 60V AC

generator

Power Booster

Power Booster

Power Booster

Power Booster

Full DPS backup + long distance remote backup by central generators.

Primary backup by DPS + power booster.Optional Secondary backup by remote central generator.

DPS4 replaces standby power supply

17

DPS v4 advantages – reduce CAPEX and OPEX• Provides unlimited standby power.• Requires no special skills to install.• Can provide double, triple or quadruple backup at a

fraction of the cost of traditional standby power systems.

• No Maintenance Required with DPS v4!• No Additional Cost after installation!

18

Power backup Comparisons

DPS V4 Generators Non Standby

Standby + Batteries

Power Type

Low High Low High Cost

Zero Permanent Negligible Permanent Maintenance

Unlimited Limited by fuel None 2 to 3 hour(Depends on

batt. condition )

Backup Power

Low cost Very expensive Low Very Expensive

Redundant/ Diversity

Typical optical network powering examples

HOT’s Backup powering business case. Improving customer service and satisfaction. Enabling HOT to add new services that required top high

reliability. Be apart of the Israeli Home Front Command new projects for

National Earthquake alarm , addressable rocket alarm, Home monitoring etc.

Unlimited backup time in competition with Bezeq which are offering 8 hours backup time to ADSL & NGN networks.

Enabling integration with future mirs mobile phone networks.

Summery DPS offers most efficient and reliable backup for unlimited time. No additional cost for HOT further to the fact that DPS unit can be

reuse from old HFC network. All existing Coax and power cables can be reuse for backup the new

optical networks. Following the government regulation for full powering backup. DPS & Power Booster system enabling additional backup from remote

central powering. No maintenance. Unlimited life time.

More of Safecom’s innovative Products .

Dual T-former 60-90V 25A Ground block with test point -20dB TV-SAT 90 degree wall socket Ingress protected home amplifier

Dual T-former 60-90V 25A outdoor + monitoring .

Mini T-former 300VA 60,90V Mini Optical Node –ingress protected

Rubber sleeve