Welcome to Homeline Homeline is GAP’s PVC-U cellular building products brand, and sits behind one of the UK’s best-known and most trusted fascia, soffit, trim, dry verge, ventilation and cladding ranges.
It’s produced in our modern 150,000 sqft production plant in Aberdare, South Wales; which is one of the largest in the UK and features a dedicated mixing plant, 12 extrusion lines, 2 foiling lines and a 100 + workforce.
2 3
Welcome to Homeline 2-3
GAP 4-5
Guarantees 6
Accreditations 7
Product Overview 8-9
Product Range 10-15
Fascias 10
Soffits 11
Trims 12
Core 14
Installation Requirements 16-17
Installation Diagrams 18
Roofline Ventilation 19
Colour Options 20-21
Product Information 22-23
“Homeline from GAP. The PVC-U roofline range of choice for Britain’s house builders.”
Through our network of 112 Depots we supply BSI and BBA-approved Homeline products to leading players in homebuilding, social housing, and building maintenance.
The range also features Homeline Core - the UK’s only BBA-approved recycled roofline products.
About Homel ine
• One Board of Directors • One Manufacturer• One Delivery Fleet • One Depot Network• One Account Manager • One Admin Team• One Invoice • One Culture• One Board of Directors • One Manufacturer• One Delivery Fleet • One Depot Network• One Account Manager • One Admin Team• One Invoice • One Culture
The Power of One • One Board of Directors• One Manufacturer• One Delivery Fleet• One Depot Network• One Account Manager• One Admin Team• One Invoice• One Culture
homel ine.uk .com4 5
Depots112 Locations
TransportWholly Owned Fleet
RooflineManufacturing
Local DeliveriesNationwide
Vertically Integrated Supply Chain
The Power of One
“Gone are the days of trying to manage several different suppliers without a common culture or single point of contact.”
homel ine.uk .com6 7Guarantees
25 YEARS
White Profiles – 25 YearsAll white PVC-U profiles will retain their decorative (no change greater than grey scale of 3) and mechanical function for a period of 25 years, under natural weathering conditions from the date of installation, provided they are installed and maintained in accordance with the procedures detailed by the BBA.
A 50 year lifetime guarantee for White profiles is available for commercial contractors upon registration and acceptance as a Homeline registered installer.
White Profiles (Core) – 25 YearsAll white PVC-U profiles will retain their decorative (no change greater than grey scale of 3) and mechanical function for a period of 25 years, under natural weathering conditions from the date of installation, provided they are installed and maintained in accordance with the procedures detailed by the BBA.
A 50 year lifetime guarantee for White profiles (Core) is available for commercial contractors upon registration and acceptance as a Homeline registered installer.
Foiled Cellular – 10 YearsAll foiled (woodgrains and colours) PVC-U profiles will retain their decorative and mechanical function for a period of 10 years, under natural weathering conditions from the date of installation, provided they are installed and maintained in accordance with the procedures detailed by the BBA.
Rainwater Profiles – 10 YearsRainwater profiles are guarantee against warping, cracking, splitting or discolouration for 10 years*, under natural weathering conditions from date of installation, provided they are installed and maintained in accordance with installation guidelines.
* Please visit www.gap.uk.com/homeline for a full guarantee certificate.
GuaranteesHomeline Building Products provide a robust guarantee policy that covers all white and foiled cellular products from discolouration, cracking and warping. We also provide guarantees for all rainwater products.
White P
rofi
les ∙
W
h i te P ro f i l es ∙ W
hit e Profiles ∙
25YEARS
Foiled Cel
lula
r ∙ F
oiled Cellular ∙ Foil e
d C
ellular ∙
10YEARS
Rainwa
ter
Pr o
f i
l es ∙ R a i n w
at e
r Pro
files ∙
10YEARS
Accreditations• BBA 09/4639 (Including Core Recycled Rooflines)
• Manufactured under ISO 9001:2015 Quality Standard
System
• Manufactured under ISO 14001:2004 Environmental
Standard
• BSI Kitemarked
• BS 7619 Specification Kitemarked
• Fire BS 476 Part 7, 1997
• BS 6105 Compliant
• Members of the BPF (British Plastics Federation)
AccreditationsProducts and processes within Homeline Building Products have been tested and inspected to ensure they comply with the most stringent product standards available, whilst also conforming to all relevant legislation within the industry.
Homeline
Gu
ara
n te e ∙ H o me l i n e G
ua
rantee∙
Product Overview
homel ine.uk .com8 9Product Overv iew
White P
rofi
les ∙
W
h i te P ro f i l es ∙ W
hite Profiles ∙
25YEARS
GUARANTEE
Foiled Cel
lula
r ∙ F
oi led Cellular ∙ Foil e
d C
ellular ∙
10YEARS
GUARANTEE
Rainwa
ter
Pr o
f i
l es ∙ R a i n w
at e
r Pro
files ∙
10YEARS
GUARANTEE
Fascia BoardsFascia boards are available in several thicknesses to suit both new builds and refurbishment projects and come in various mouldings and colours to suit building designs and styles.
Joints & CornersA large range of rigid and flexible joints, corners and trims are available to provide a neat finish to all roofline applications.
Soffit Boards Soffit boards are available in solid, pre-ventilated and hollow designs to suit building designs. They provide the return from the fascia board lip back to the brick work and can be used to ventilate the roof space.
VentilationVentilation is commonly provided through the use of over fascia ventilators which give continuous air flow to the roof space and prevent condensation. Ventilated soffit boards can also be used to provide ventilation to the roof space. See pg 19 for more information.
Dry Verge Dry Verge provides a mortar-free and secure method of fixing concrete interlocking verge tiles. Its neat interlocking design provides a consistent appearance that requires no maintenance.
RainwaterAvailable in five different styles to suit rainwater flow rates and six different colours, Homeline’s rainwater systems work perfectly with all our fascia boards.
BargeboardBargeboard use standard fascia boards as a method of covering the gable end of the roofline.
Not to be used as a cladding
Square 22mm
150m
m -
GJF
150W
175m
m -
GJF
175W
200m
m -
GJF
200W
225m
m -
GJF
225W
250m
m -
GJF
250W
405m
m -
GJF
405W
33mm
22mm
Bullnose 22mm
150m
m -
GB
J150
W
175m
m -
GB
J175
W
200m
m -
GB
J200
W
225m
m -
GB
J225
W
250m
m -
GB
J250
W
405m
m -
GB
J405
W
24mm
22mm
Square 16mm
150m
m -
GS
F150
W
175m
m -
GS
F175
W
200m
m -
GS
F200
W
225m
m -
GS
F225
W
250m
m -
GS
F250
W
300m
m -
GS
F300
W
405m
m -
GS
F405
W33mm
16mm
Bullnose 16mm
150m
m -
GFB
150W
175m
m -
GFB
175W
200m
m -
GFB
200W
225m
m -
GFB
225W
250m
m -
GFB
250W
405m
m -
GFB
405W
24mm
16mm
Ogee 16mm
28mm
16mm
150m
m -
GO
F150
W
175m
m -
GO
F175
W
200m
m -
GO
F200
W
225m
m -
GO
F225
W
250m
m -
GO
F250
W
405m
m -
GO
F405
W
Ogee Cap Over 9mm
150m
m -
GG
F150
W
175m
m -
GG
F175
W
200m
m -
GG
F200
W
225m
m -
GG
F225
W
250m
m -
GG
F250
W
405m
m -
GG
F405
W
39mm
9mm
Square Cap Over 9mm
150m
m -
GR
C15
0W
100m
m -
GR
C09
5W
175m
m -
GR
C17
5W
200m
m -
GR
C20
0W
225m
m -
GR
C22
5W
250m
m -
GR
C25
0W
300m
m -
GR
C30
0W
400m
m -
GR
C40
0W
605m
m -
GR
C60
5W
39mm
9mm
homel ine.uk .com10 11
A comprehensive selection of fascia boards are available in various styles and thicknesses with different return leg sizes designed to cover the lip of the soffit board. All fascias are available in a range of heights with double ended boards for boxends. Soffit boards are available in solid, pre-ventilated and hollow options in various widths.
Fascia Boards
Perfe
ct fo
r new build
Cap Over Boards
Product Range
Vented Soffit Board 9mm*
Hollow SoffitDouble Vented Soffit Board 9mm*
Solid Soffit Board 9mm
9mm
100mm - GMB100W
125mm - GMB125W
150mm - GMB150W
175mm - GMB175W
200mm - GMB200W
225mm - GMB225W
250mm - GMB250W
300mm - GMB300W
405mm - GMB405W
450mm - GMB450W
500mm - GMB500W
605mm - GMB605W
9mm
150mm - GVB150W
175mm - GVB175W
200mm - GVB200W
225mm - GVB225W
250mm - GVB250W
300mm - GVB300W
405mm - GVB405W
450mm - GVB450W
605mm - GVB605W
9mm
300mm - GHC300W
Soffit Boards
175m
m -
GFF
175W
200m
m -
GFF
200W
225m
m -
GFF
225W
16mm
16mm
150m
m -
GFF
150W
250m
m -
GFF
250W
405m
m -
GFF
405W
Flat 16mm
Product Range
150mm - GDVB150W
300mm - GDVB300W
405mm - GDVB405W
450mm - GDVB450W
* Please see Ventilation guide at www.gap.uk.com/homeline
125m
m -
GR
C12
5W
Product Range
Over Fascia VentilatorCircular Vent
500mm - C5031000mm - G1200N1000mm - G2500N
Combed Vent
900mm - C402200mm
Over Fascia Protection
1500mm - C400200mm
Jumbo Vent
900mm - C401180mm
Soffit Joint Trim
5m GHSW
Centre Joint Trim
5m GCJW
2 Part External Corner
5m G2ECW
J Trim
5m GJTW
Felt Roof Edge Trim
5m GFREW
U Channel
5m GUCW
70mm - GCVW
70mm
2 Part Universal Trim
5m G2UCW
Decorative Fascias Convex 16mm200mm GDFVW
Decorative Fascias Concave 16mm200mm GDFCW
Single Ended Joints
Sq
uar
e -
300m
m -
GR
JW
Og
ee -
300
mm
- G
OJW
Double Ended Joints
Sq
uar
e -
500m
m -
GS
J500
W
Bu
llno
se -
500
mm
- G
BJ5
00W
Og
ee -
500
mm
- G
OJ5
00W
Single Ended Corners
Sq
uar
e -
300m
m -
GIS
C30
0W
Og
ee -
300
mm
- G
IOC
300W
Og
ee -
300
mm
- G
OC
W
Sq
uar
e (1
35˚)
- 3
00m
m -
G13
5RC
W
Sq
uar
e (1
35˚)
- 3
00m
m -
G13
5IR
CW
Sq
uar
e -
300m
m -
GR
CW
Double Ended CornersInternal
Bu
llno
se -
600
mm
- G
IBC
500W
External
Sq
uar
e -
500m
m -
GS
C50
0W
Bu
llno
se-
500m
m -
GB
C50
0W
Og
ee -
500
mm
- G
OC
500W
Flat Back Spire
3D Spire
910mm - GFBS
910mm - G3DW
Bracing Bar
Ball End Finial
965mm - GBF965W1500mm - GBF1500W
1500mm - GBBW
Gable Finial340mm x 100mm - GFINW
homel ine.uk .com12 13
To provide finishing touches a range of trims, joints and corners are available for roofline installations. Ventilation options are provided through over fascia ventilators or circular vents for the soffit.
Finishing Touches
Joints
Ventilation
Trims
Product Range
“The complete solution for PVC-U rooflines.”
Please see Ventilation guide at www.gap.uk.com/homeline
homel ine.uk .com14 15Core
Virgin PVC-U Outer Skin
To ensure colour stability and exact colour matching, we use the same process as our standard fascias for the outer skin of the roofline system. This means once installed – it’s impossible to tell the difference between a standard and recycled roofline.
100% Recycled Inner Core
We use recycled foam products which are processed and then pulverised into pellets to ensure they can be re-extruded into our inner core. The difference in colour is a natural occurrence based on different coloured foams being recycled. Don’t forget that once installed you can’t see the inner core.
Solid Soffit Board 9mm
9mm
100mm - EMB100W
150mm - EMB150W
175mm - EMB175W
200mm - EMB200W
225mm - EMB225W
250mm - EMB250W
300mm - EMB300W
400-mm - EMB405W
450mm - EMB450W
500mm - EMB500W
605mm - EMB605W
Square 16mm
Core is Homeline’s exclusive range of BBA-approved rooflines. Included in the range are full replacement fascia boards, soffit boards and a cap over board.
Fascia Board
Product Range
150m
m -
ES
F150
W
175m
m -
ES
F175
W
200m
m -
ES
F200
W
225m
m -
ES
F225
W
250m
m -
ES
F250
W
405m
m -
ES
F405
W
33mm
16mm
Cap Over Board
Soffit Board
25 YEARS
Whether you’re a House Builder or Specifier, using BBA-approved Core rooflines will demonstrate you’re committed to using top quality recycled materials on your development, from one of the most forward thinking and environmentally friendly roofline manufacturers.
recycled into our core, not the earths.
Square Cap Over 9mm
150m
m -
ER
C15
0W
100m
m -
ER
C09
5W
175m
m -
ER
C17
5W
200m
m -
ER
C20
0W
225m
m -
ER
C22
5W
250m
m -
ER
C25
0W
300m
m -
ER
C30
0W
400m
m -
ER
C40
0W
605m
m -
ER
C60
5W
39mm
9mm
homel ine.uk .com16 17
Fascia Boards
• Full replacement fascia boards are fixed directly to rafter ends at centres not exceeding 600mm for white and 400mm for foiled profiles, using 2 x 65mm A4 marine grade stainless steel plastic headed nails.
• Cap over fascias should be fixed as above, as well as using a backing board of marine grade plywood of not less than 12mm thick.
• Butt joints between fascia boards should be made at the rafter end and covered with fascia joint, fixed to the end of one board with either a low-modulus silicone sealant or a solvent-weld adhesive. Provision for expansion (minimum 10mm in-between two 5m boards) should be allowed between boards.
• At corners the joint is covered with a corner trim, fixed to the end of one board only with a plastic headed pin, solvent-weld adhesive or low-modulus silicone sealant. Provision for thermal movement of the boards should be allowed as above.
• PVC-U gutter systems as specified to BS4576-1:1989 may be screw-fixed directly to full replacement fascia boards. Gutter bracket spacing must not exceed 1m and are typically at a maximum no greater than 800mm centres.
Soffit Boards
• Soffit boards are cut to size and fitted into the groove at the rear of the fascia.
• The boards are fixed to rafter feet, soffit bearers or other timber support at centres along their length, not exceeding 600mm for white and 400mm for foiled profiles, and across their width, not exceeding 200mm, using 2 x 40mm A4 marine grade stainless steel plastic headed pins.
• Where required, soffit boards may be joined along their length or width leaving a 4mm expansion gap at each board end using a soffit joint strip.
• To comply with building regulations, a vented soffit board, soffit ventilator or over fascia ventilation should be used as required.
Bargeboards
• Bargeboards are installed by fixing fascia boards to a gable ladder.
• Bargeboards meeting at a ridge should be mitred to the appropriate angle. A fascia joint or finial should be used to cover the joint.
• Box ends are constructed from a larger depth fascia board and trimmed to suit the roof pitch.
Installation Requirements• Selected boards and accessories are assembled and cut to size. • Rafter feet are cut to a line. • Soffit bearers, battens, eaves fillets, brackets and other additional
timber supports are fixed to a sound substrate.
• Remove protective film before or straight after installation.
Eaves Protector &Over Fascia Ventilator
Soffit Plastic Headed Pin
Plastic Headed Nail
16mm Square Fascia
SquareRainwater
Remaining Felt positioned over Eaves Protector
Plain Soffit
Plastic Headed Nail
Plastic Headed Pin
Plastic Headed Pin
16mmSquare Fascia
Dry Verge
Square Fascia & Soffit
Bargeboard & Soffit
16mm square fascia boards should be nailed directly to rafter ends with ventilation provided through over fascia ventilators. The gap between the fascia and the brick should be closed using a 9mm soffit board.
16mm square fascia boards should be used to protect the bargeboard on the gable end of the roof with interlocking or continuous dry verge being used to protect the verge. The gap between the fascia and the brick should be closed using a 9mm soffit board.
Insta l la t ion Requirements
External Corner
Roofline Ventilation guide is available on
our website.
homel ine.uk .com18 19
5mm*
10mm10mm
10mm
5mm
Pitches of 15° or less require 25mm at eaves
25mm25mm
5mm
25mm 25mm
* For pitches over 35° or spans in excess of 10m
Insta l la t ion Diagrams
Installation Diagrams
Min5mm
Min5mm
FasciaBoard
FasciaJoint
FasciaBoard
Min10mm
FasciaBoard
FasciaBoard
FasciaCorner
Min5mm
Top Elevation Top Elevation
Min5mm
Min10mm
SoffitBoard
SoffitBoard
FasciaBoard
SoffitJoint
FasciaBoard
FasciaBoard
Internal Corner
Min5mm
Min5mm
Fascia Joints Soffit Joints Pitch Over 15
Pitch Under 15° Warm Roofs
Internal Corner
Roofline Ventilation Homeline vented soffit boards are covered by the BBA certificate 09/4639. When used in accordance with this certificate they provide a simple and effect method for meeting building regulations.
Fascia Fixing PointsHomeline fascia boards are easy to install thanks to horizontal lines on the protective film. This ensures the plastic headed nails are perfectly level and spaced accurately along the board at either 600mm (white) or 400mm (foils) centres.
homel ine.uk .com
• The Building Regulations 2000 (as amended) (England and Wales)
• Requirement C2 (b)(c) Resistance to Moisture and Regulation 7: Materials and workmanship.
• The Building (Scotland) Regulations 2004 (as amended)
• Regulation 8 (1) (2): Fitness and durability of materials and workmanship.
• Regulation 9: Building Standards – Construction.
• Standard 3.15 – Condensation.
• The Building Regulations (Northern Ireland) 2000
(as amended)
• Regulation B2: Fitness of materials and workmanship.
• Regulation B3(2): Suitability of certain materials.
• Regulation C4(b): Resistance to ground moisture and weather.
• Regulation C5: Moisture.
• For duo roof pitches of 15˚ and over but less than 70˚ where both ceiling and insulation are horizontal : Eaves level ventilation equivalent to 10mm of clear continuous air flow per metre run on both sides of a roof allowing adequate cross-ventilation.
• For duo roof pitches of 15˚ and over but less than 70˚ where both ceiling and insulation are horizontal : Eaves level ventilation equivalent to 10mm of clear continuous air flow per metre run on both sides of a roof allowing adequate cross-ventilation.
• For duo roof pitches of 15˚ and over where the ceiling follows the pitch of the roof: Eaves level ventilation to 25mm of continuous air flow per metre run on both sides of a roof.
• For duo roof pitches where the ceiling follows the pitch of the roof: Eaves ventilation equivalent to 25mm of continuous air flow per metre run. It is essential that a minimum unrestricted air space of 50mm is maintained between the underside of the roof deck and the top of the insulation. Consideration should be given to the probability of the sarking felt bowing between the rafters and it should be ensured that does not reduce the gap between felt and insulation to less than 50mm.
• For roof pitches less than 15˚ (including flat deck roof construction): Eaves level ventilation equivalent to 25mm of clear continuous air flow per metre run on both sides of a roof allowing adequate cross- ventilation.
• Eaves ventilation should be provided to the whole area of the eaves giving complete comprehensive airflow. When providing roof space ventilation for flat roofs, it is essential that a minimum unrestricted airspace of 50mm is maintained between the underside of the roof deck; where possible these should be the longest sides to achieve maximum cross-ventilation. Duo Pitched roofs of 20˚ and over or greater than a 10m span, should have additional ventilation provided at the ridge equivalent to at least 3mm wide continuous gap.
5mm*
10mm10mm
10mm
5mm
Pitches of 15° or less require 25mm at eaves
25mm25mm
5mm
25mm 25mm
* For pitches over 35° or spans in excess of 10m
Pitch Over 15
Pitch Under 15° Warm Roofs
Roofline Ventilation Homeline vented soffit boards are covered by the BBA certificate 09/4639. When used in accordance with this certificate they provide a simple and effect method for meeting the following building regulation requirements :
Single vented boards offer a 14mm continuous slot or 14,000 square mm pre linear metre, with double vented boards offering a 28mm continuous slot or 28,000 square mm pre linear metre.
For more information relating to ventilation, please visit www.gap.uk.com/homeline
Black Code .BLRAL 8022
Dark Grey Code .DG RAL 7016
Slate Grey Code .SGRAL 7015
Anthracite Grey Code .AG RAL 7016
Foiled WhiteCode .FWRAL 9010
White Code .WRAL 9003 (Virgin skin no foil)
CreamCode .CRRAL 9001
Colour Options Homeline rooflines are available in several colour and finish options (smooth and grained) as shown above. For exact colour options, please ask your representative for a colour swatch.
• Reflects 80% of the sun’s harmful rays
• 12 times thicker than traditional foils
• 250 microns thick
• Difficult to scratch due to thickness of foil
Heat Shield Protection Exclusive to Homeline, Heat Shield is a revolutionary technology that prevents coloured or woodgrain foils from warping, bending, cracking or bubbling.
homel ine.uk .com20 21
Grained
A woodgrain embossed finish which matches PVC-U window and door profiles.
Smooth
A smooth finish to replicate the appearance of Aluminium profiles.
For Appearance, Durability and Colourfastness please see page 22.
Rustic GreenCode .RGRAL 6009
Chartwell GreenCode .CG
Royal BlueCode .RBRAL 5011
Wine RedCode .WRRAL 3011
Irish OakCode .IO
Light OakCode .LO
RosewoodCode .R
WoodgrainCode .WG
Colour Opt ions
Environmental Information
Homeline Building Products takes its impact on the environment seriously. We are committed to providing quality products and services which comply with all relevant environmental legislation and we strive to use pollution prevention and environmental best practices in all aspects of our operation.
• 100% recyclable
• Can be recycled up to 10 times
• More thermally efficient than timber
• Weather resistant
• Working life of over 40 years
• Never needs painting
• Recycled roofline option available
Product Information
Appearance
Products are free from sink marks, cracks or foreign bodies when viewed at 90˚ to the surface at a distance of 1m in diffused north light.
Density
The density of Homeline Cellular PVC-U is on average 500 kg/m.
Durability
Products will retain their physical integrity for many years. Visually they will age uniformly with only minimum changes to appearance. White and foiled products carry comprehensive guarantees (please see pg. 6 for more details). Hollow Soffit must not be used as a cladding.
Colourfastness
All our products have passed the U.V. aged impact tests and the colourfast requirements set out in BS7619. All white products will not change greater than a Grey scale of 3 when exposed to normal weather conditions experienced in northern Europe.
Chemical Resistance
In order to preserve the high quality surface finish it is recommended that only warm soapy water is used to clean the product as required.
Fire Classification
When tested in accordance with BS476-7 : 1997, full replacement fascia boards achieve a Class 1 surface spread of flame rating. Soffit and the hollow soffit achieve a Class 1Y rating.
Impact Resistance
All Homeline products are certified by BS7619 for impact tests.
Softening Point
Homeline cellular products have a softening point in the region of 70˚C.
Heat Shield
Standard on all Homeline foils, Heat Shield technology prevents heat from being absorbed into the profile preventing warping, bending and twisting.
Water Absorption
Tests have been carried out to BS EN ISO 62 1999 and typically Homeline cellular products have a water retention of < 1%.
Thermal Movement & Conductivity
The co-efficient of linear expansion for our white products at 20˚C is 5 x 10 - 5 as tested in accordance with BS4370-3 1998. For 9mm thick fascia profiles it is recommended that a 5mm expansion gap is given to both ends of the board. For foiled products it is recommended that an 8mm expansion gap is used both ends of the product. Homeline Building Products have been tested in accordance with BS4370-2 1993 resulting in a value of 0.062W/mK which is greater than the equivalent soft wood product.
Loading
Full replacement fascia boards will support eaves tiles in common usage, provided they are installed in accordance with manufacturer’s guidelines.
Product InformationHomeline Building Products are manufactured and tested to BS7619 and our manufacturing facility has been accredited to ISO 9001:2015 and 14001:2004.
homel ine.uk .com22 23
Handling & Storage
PVC-U cellular products are relatively light and easy to handle due to their composition. Therefore, when handling our products all you need to do is ensure both ends of the profile are supported to prevent the product being damaged.
It is advisable that products are stored under cover, with the face against a flat firm surface. If stacked (i.e. not in a steel stillage), do not exceed 1m in height. Cellular products are protected using polythene lo-tac film with fixing points on fascia boards.
Distribution
Products are delivered to site or storage facilities using GAP’s own dedicated delivery fleet from 112 depot locations strategically located across the UK.
Working with Materials
PVC-U by its very nature is virtually maintenance free. Once installed, we recommend the products are cleaned using soapy water to remove any dirt or dust that has gathered. Cutting and shaping of PVC-U is quite easy and existing carpentry tools may be utilised. It is recommended that the protective tape is removed either immediately before or straight after fitting, as exposure to sunlight can make the tape very difficult to remove.
Health & Safety
When cutting or shaping materials, ensure adequate protection is taken to avoid any injury. Protective eye and hand equipment should be worn. COSHH sheets available on request
Product In format ion
recycled into our core, not the earths.
GAP LtdPartnership WayShadsworth Business ParkBlackburnBB1 2QP
T: 0845 313 10 12 F: 0845 313 03 13W: gap.uk.comS: @GAPLtdGeneral All-Purpose Plastics Ltd, T/A GAP LtdRegistered No: 02767596
All photographs, colours and images are to be considered as representative of the actual product. Homeline reserve the right to change colours, sizes or designs without prior notice.
Homeline is a registered trade mark ® 2377290. GHBP-PG-05-11/17.
gap.uk.com
top related