Parameter

2009-12-20 15:37

RNC, RN5.0

Parameter name

CPICH Ec/No Offset

Cell Identifier

Change origin

Disable Effect on Reporting Range

HSDPA HOPS identifier

HSDPA HOPS identifier for AMR multi-service

Include in System Information

Intra-frequency adjacency identifier

Location Area Code

Maximum UE TX Power on RACH

Mobile Country Code

Mobile Network Code

Mobile Network Code Length

NRT HOPS Identifier

Primary CPICH power

Primary Scrambling Code

RNC Identifier

RT HOPS Identifier

Routing Area Code

Tx Diversity Indicator

Abbreviated name

AdjsEcNoOffset

AdjsCI

ADJSChangeOrigin

AdjsDERR

HSDPAHopsIdentifier

RTWithHSDPAHopsIdentifier

AdjsSIB

ADJSId

AdjsLAC

AdjsTxPwrRACH

AdjsMCC

AdjsMNC

AdjsMNCLength

NrtHopsIdentifier

AdjsCPICHTxPwr

AdjsScrCode

AdjsRNCid

RtHopsIdentifier

AdjsRAC

AdjsTxDiv

3GPP name

Cell individual offset

Cell Identity; C-Id

Cells forbidden to affect Reporting range

Location Area Code; LAC

Maximum allowed UL TX power; UE_TXPWR_MAX_RACH

Mobile Country Code; MCC

Mobile Network Code; MNC

Primary CPICH power

Primary scrambling code

RNC Identifier; RNC-Id

Routing Area Code; RAC

Tx diversity indicator

Parameter group

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

Identification

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

HCConfiguration

Category

Radio Resource Utilisation

Radio Resource Utilisation

Operation and Maintenance

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Operation and Maintenance

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Radio Resource Utilisation

Multiplicity:

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Description

The parameter defines the origin of the last configuration action affecting the object.

The downlink scrambling code of the Primary CPICH (Common Pilot Channel) of the intra-frequency neighbour cell.

The CPICH Ec/No Offset determines an offset value, which the UE adds to the CPICH Ec/No measurement result of the neighbouring cell before it compares the Ec/No value with the reporting criteria.An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier.

This parameter indicates whether the neighbouring cell is forbidden to affect the reporting range (addition/drop window) calculation, if it belongs to the active set.

The parameter identifies the parameter set (HOPS object) controlling the intra-frequency handovers of a user having HS-DSCH allocated.

This parameter identifies the parameter set (HOPS object) controlling intra-frequency handovers of a user having HS-DSCH allocated simultaneously with AMR speech CS RAB.

The parameter determines whether the intra-frequency neighbour cell is included in the System Information Block 11&12&18 for the cell selection and re-selection procedures. The intra-frequency neighbour cell is included in the system information when the value of the parameter is "SIB". The intra-frequency neighbour cell is included in the Identification of ADJS (Intra-Frequency Adjacency) within a WCDMA cell.

The PLMN Identifier and the Location Area Code (LAC) determine the Location Area (LAI) to which the intra-frequency neighbour cell belongs to.

This parameter indicates the maximum transmission power level that a UE can use when accessing the neighbouring cell on the RACH. The UE uses the parameter in the cell re-selection procedure. If the maximum output power of the UE is lower than the value of the parameter, the UE adds the power difference (dB value) to the minimum required An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. Furthermore, the Global RNC Identifier is composed of the PLMN Identifier, which consists of the Mobile Country Code (MCC), the Mobile Network Code (MNC), and the RNC Identifier.An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. Furthermore, the Global RNC Identifier is composed of the PLMN Identifier, which consists of the Mobile Country Code (MCC), the Mobile Network Code (MNC), and the RNC Identifier.The parameter defines whether 2 or 3 digits are used in the Mobile Network Code (MNC).

When this parameter is modified also the MNC value used by the system is always changed.This parameter defines the parameter set (HOPS object) which controls the intra-frequency handover of a non-real time (NRT) radio bearer to the neighbouring cell.

This parameter indicates the transmission power level of the Primary CPICH (Common Pilot Channel) of the intra-frequency neighbour cell.

An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. The Global RNC Identifier is composed of the PLMN Identifier and the RNC Identifier.

This parameter defines the parameter set (HOPS object) which controls the intra-frequency handover of a real time (RT) radio bearer to the neighbouring cell.

The Location Area (LAI) and the Routing Area Code (RAC) determine the Routing Area to which the intra-frequency neighbour cell belongs to.

This parameter indicates whether the Primary CPICH of the intra-frequency neighbour cell is broadcast from two antennas. If the Primary CPICH is broadcast from two antennas, the UE measures the received code power from each antenna separately and sums the measurement results together in order to get the total received code power on

Range:

-10..10

1..65535

0 (No), 1 (Yes)

1..100

1..100

0 (No), 1 (SIB), 2 (SIBbis)

1..31

1..65535

-50..33

0..999

0..999

2 (2), 3 (3)

1..100

-10..50

0..511

1..4095

1..100

0..255

0 (Not defined), 1 (Network originated configuration action), 2 (NetAct RNW plan originated configuration action), 3 (Element Manager originated configuration action), 4 (Configuration action by automatic tuning function), 5 (Element Manager originated mass config action), 6 (NetAct originated direct RNW change)

0 (Tx Diversity not used), 1 (Tx Diversity in use)

Step:

0.5

1

-

-

1

1

-

1

1

1

1

1

-

1

0.1

1

1

1

1

-

Unit:

dB

-

-

-

-

-

-

-

-

dBm

-

-

-

-

dBm

-

-

-

-

-

Formula for getting internal value

= UI_value * 2

= UI_value

= UI_value

= UI_value

= UI_value

= UI_value

= UI_value

= UI_value

= UI_value

= UI_value

= UI_value * 10

= UI_value

= UI_value

= UI_value

= UI_value

Default value

0

0

1

2

0

Default value notes

Default value is not possible.

Value is set by the system

The neighbouring cell can affect the reporting range calculation, if it belongs to the active set.

Default value is not possible

Default value is not possible.

The intra-frequency neighbour cell is included in the System Information.

Default value is not possible

Default value is not possible

Default value is not possible

Default value is not possible.

Default value is not possible.

Default value is not possible

Default value is not possible

Default value is not possible.

Default value is not possible

Default value is not possible

Required on creation

Mandatory

Mandatory

Mandatory

Mandatory

Optional

Optional

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Mandatory

Special value

0

0

Related functions

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Mobile Device Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control

- Handover Control- Mobile Device Control

- Handover Control- Mobile Device Control

System information

- SIB18

- SIB18

- SIB11

- SIB11- SIB12- SIB18- SIB11- SIB12

- SIB11- SIB12

- SIB11- SIB12- SIB18- SIB11- SIB12- SIB18

- SIB11- SIB12

- SIB11- SIB12- SIB18

- SIB11- SIB12

Modification

onLine

onLine

unmodifiable

onLine

onLine

onLine

onLine

unmodifiable

onLine

onLine

onLine

onLine

onLine

onLine

onLine

onLine

onLine

onLine

onLine

onLine

Modified

ADJS creation and modification

ADJS creation and modification

ADJS creation and modification

ADJS creation and modification

ADJS creation and modification.

ADJS creation

ADJS creation and modification (with restrictions)

ADJS creation and modification

ADJS creation and modification (with restrictions)

ADJS creation and modification (with restrictions)

ADJS creation and modification

ADJS creation and modification (with restrictions). The modification is not possible if the neighbour cell is controlled by the local RNC.

ADJS creation and modification (with restrictions). The modification is not possible if the neighbour cell is controlled by the local RNC.

ADJS creation and modification

Related parameters

- DropWindow of FMCS

- HSDPAenabled of WCEL

- UEtxPowerMaxPRACH of WCEL

- AdjsMNCLength of ADJS

- AdjsMNC of ADJS

- HOPSId of HOPS

- PriScrCode of WCEL

- HOPSId of HOPS

- HOPSId of HOPS- HSDPAenabled of WCEL- AMRWithHSDSCH of RNC

Parameter relationships

The modification is always possible except if the new target cell is existing in local RNC. In this case the modification is done via the WCEL object. Cross-check between RNC, WCEL and ADJS objects is required.

The value must always be 0 (not used) if the intra-frequency neighbour cell is controlled by the local RNC; cross-check between RNC, WCEL and ADJS objects is required.

Related features

HSDPA (optional)

HSDPA (optional) AND HSDPA with Simultaneous AMR Voice Call (optional)

Extension of sib11 (standard)

Interfaces

- RNC <-> UE

- RNC <-> UE- RAC <-> RNC- EM <-> RNC- RNC -> RAC- RNC -> EM

- RNC <-> UE- RAC <-> RNC- EM <-> RNC- RAC <-> RNC- EM <-> RNC- RACApp <-> RAC- RAC <-> RNC- EM <-> RNC- RACApp <-> RAC- RAC <-> RNC- EM <-> RNC- RAC <-> RACApp- RAC <-> RNC- EM <-> RNC- RACApp <-> RAC- RNC <-> MSC- RAC <-> RNC- EM <-> RNC- RNC <-> UE- RAC <-> RNC- EM <-> RNC- RNC <-> MSC- RAC <-> RNC- EM <-> RNC- RNC <-> MSC- RAC <-> RNC- EM <-> RNC- RAC <-> RNC- EM <-> RNC

- RAC <-> RNC- EM <-> RNC- RACApp <-> RAC- RAC <-> RNC- EM <-> RNC- Planner <-> RAC- RNC <-> UE- RAC <-> RNC- EM <-> RNC- RNC <-> MSC- RAC <-> RNC- EM <-> RNC- RAC <-> RNC- EM <-> RNC- RACApp <-> RAC- RNC <-> MSC- RAC <-> RNC- EM <-> RNC

- RNC <-> UE- RAC <-> RNC- EM <-> RNC

References

- Undefined:1080

- Undefined:830

- Undefined:988

- Undefined:1091

- Undefined:1091

- Undefined:1091

- Undefined:748 (public)- Undefined:839- Undefined:841

- Undefined:1091- Undefined:723 (public)

- Undefined:986- Undefined:1243

- Undefined:839- Undefined:737 (public)- Undefined:841- Undefined:843- Undefined:701 (public)- Undefined:722 (public)- Undefined:839- Undefined:841- Undefined:737 (public)- Undefined:737 (public)- Undefined:839- Undefined:841- Undefined:723 (public)- Undefined:737 (public)

- Undefined:753 (public)- Undefined:843

- Undefined:841- Undefined:722 (public)- Undefined:839- Undefined:841- Undefined:737 (public)

- Undefined:841- Undefined:737 (public)- Undefined:839

- Undefined:722 (public)- Undefined:1091

Struct parameter

top related