rida gene kits for real-time pcr - mediline.si · rida®gene kits for real-time pcr r-biopharm ag...
Post on 01-Sep-2018
222 Views
Preview:
TRANSCRIPT
R-Biopharm – for reliable diagnostics.
RIDA®GENE Kits for real-time PCR
R-Biopharm AG
Hospital Acquired Infections
Respiratory Infections
Gastro-intestinal Infections
RIDA®GENE Real-time PCR
EHEC/EPEC Real-time multiplex PCR for the direct qualitative detection and differentiation of EHEC, STEC, EPEC and EIEC/Shigella spp. in human stool samples and culture
100 stool/culture
PG2205
EAEC Real-time PCR for the direct qualitative detection of enteroaggregative E. coli (EAEC) in human stool samples and culture
100 stool/culture
PG2215
ETEC/EIEC Real-time multiplex PCR for the direct qualitative detection and differentiation of ETEC and EIEC/Shigella spp. in human stool samples and culture
100 stool/culture
PG2225
STEC Real-time multiplex PCR for the direct qualitative detection and differentiation of Shiga-toxin genes (stx1 and stx2) of Shiga-toxin producing E. coli (STEC) in human stool samples and culture
100 stool/culture
PG2255
STEC LC2.0 Real-time multiplex PCR for the direct qualitative detection and differentiation of Shiga-toxin genes (stx1 and stx2) of Shiga-toxin producing E. coli (STEC) in human stool samples and culture on the LightCycler® 2.0
100 stool/culture
PG2275
Bacterial Stool Panel Real-time multiplex PCR for the direct qualitative detection and differentiation of Salmonella spp., Campylobacter spp. and Yersinia enterocolitica in human stool samples
100 stool PG2405
Norovirus Real-time RT-PCR for the direct, qualitative detection of norovirus (genogroup I and II) in human stool samples
100 stool PG1405
Norovirus I & II Real-time multiplex RT-PCR for the direct qualitative detection and differentiation of norovirus genogroup I and genogroup II in human stool samples
100 stool PG1415
Norovirus I & II LC 2.0 Real-time multiplex RT-PCR for the direct qualitative detection and differentiation of norovirus genogroup I and genogroup II in human stool samples on the LightCycler® 2.0
100 stool PG1425
Rotavirus/Adenovirus Duplex
Real-time multiplex RT-PCR for the qualitative detection and differentiation of rotavirus and adenovirus in human stool samples
100 stool PG0905
Parasitic Stool Panel Real-time multiplex PCR for the qualitative detection and differentiation of Giardia lamblia, Entamoeba histolytica, Cryptosporidium parvum and Dientamoeba fragilis in human stool samples
100 stool PG1705
Product Description Tests Matrix Art. No.
Gastrointestinal Infections
Molecular Diagnostics
RIDA®GENE Real-time PCR
MRSA Real-time multiplex PCR for the direct qualitative detection of MRSA in human nasal swabs and culture
100 nasal swab/culture
PG0605
MRSA LC2.0 Real-time multiplex PCR for the direct qualitative detection of MRSA in human nasal swabs and culture on the LightCycler® 2.0
100 nasal swab/culture
PG0625
PVL Real-time PCR for the direct qualitative detection of the PVL-gene (Panton-Valentine leukocidine) in human nasal swabs and culture
100 nasal swab/culture
PG0645
Hospital Stool Panel Real-time multiplex PCR for the direct qualitative detection and differentiation of norovirus (genogroup I and II), rotavirus and Clostridium difficile toxin genes A (tcdA) and B (tcdB) in human stool samples
100 stool PG0705
Clostridium difficile* Real-time multiplex PCR for the direct qualitative detection of Clostridium difficile and Clostridium difficile toxin genes A (tcdA) and B (tcdB) in human stool samples
100 stool PG0835
Clostridium difficile LC2.0* Real-time multiplex PCR for the direct qualitative detection of Clostridium difficile and Clostridium difficile toxin A (tcdA) and toxin B (tcdB) genes in human stool samples on the LightCycler® 2.0
100 stool PG0845
CD Toxin A/B Real-time PCR for the direct qualitative detection of Clostridium difficile toxin genes A (tcdA) and B (tcdB) in human stool samples
100 stool PG0825
Clostridium difficile HyperTox
Real-time multiplex PCR for the direct qualitative detection and differentiation of the hypervirulent Clostridium difficile ribotype 027 and the 078-like-group in human stool samples
50 stool PG0855
Product Description Tests Matrix Art. No.
Molecular Diagnostics
Hospital Acquired Infections
Product Description Tests Matrix Art. No.
Respiratory Infections
* soon available
RIDA®GENE Real-time PCR
Flu Real-time multiplex RT-PCR for the direct qualitative detection and differentiation of Influenza A, Influenza B and H1N1v in human nasal swabs and throat swabs
100 nasal swab/ throat swab
PG0505
Flu LC2.0 Real-time multiplex RT-PCR for the direct qualitative detection and differentiation of Influenza A and Influenza B in human nasal swabs and throat swabs on the LightCycler® 2.0
100 nasal swab/ throat swab
PG0525
Bordetella* Real-time multiplex PCR for the direct qualitative detection and differentiation of Bordetella pertussis and Bordetella parapertussis in human nasopharyngeal swabs
100 naso- pharynageal swab
PG2505
10/2
012
R-Biopharm AG, An der neuen Bergstraße 17, 64297 DarmstadtPhone: +49 (0) 61 51 - 81 02-0, Fax: +49 (0) 61 51 - 81 02-20 info@r-biopharm.de, www.r-biopharm.com
RIDA®GENE Product features
• Multiplex real-time PCR kits• One PCR profile for DNA and RNA assays• Can be run on the commonly used real-time PCR instruments• Can be used with different extraction systems (manual/automatic)• Time to result < 1.5 hours• Internal Control• Complete test kits (all reagents included)• QCMD and ring trial validated• CE-marked
Overview RIDA®GENE real-time PCR instruments
1 RIDA®GENE IAC Plus Accessory reagent is required except for Norovirus and Norovirus I & II2 RIDA®GENE Color Compensation Kit I required except Clostridium difficile3 RIDA®GENE Color Compensation Kit II required
Hospital Acquired Infections Gastrointestinal Infections Respiratory Infections
Real-time PCR instrument CD
Tox
in A
/B
Clo
strid
ium
diffi
cile
Hyp
erTo
x
Clo
strid
ium
diffi
cile
M
RSA
Hos
pita
l Sto
ol P
anel
PVL
MRS
A L
C 2
.0
Clo
strid
ium
diffi
cile
LC
2.0
Bact
eria
l Sto
ol P
anel
EHEC
/EPE
CET
EC/E
IEC
STEC
EAEC
Nor
ovir
us
STEC
LC
2.0
Nor
ovir
us I
& II
LC
2.0
Nor
ovir
us I
& II
Ro
tavi
rus/
Ade
novi
rus
Dup
lex
Par
asiti
c St
ool P
anel
Flu
Bo
rdet
ella
Flu
CL
2.0
Roche LightCyler® 1.5 3 3 3
LightCyler® 2.0 3 3 3 3 3 3
LightCyler® 480 2 2 2 2 2
Cepheid SmartCycler ® 1 1 1
Applied Biosystems
ABI 7000
ABI 7300
ABI 7500
ABI 7700
ABI 7900 HT
StepOne
Abbott m2000rt
Stratagene Mx3000P
MX3005P
Qiagen Rotor-Gene Q
For more information, contact your R-Biopharm Account Manager at:Phone: +49 (0) 61 51 - 81 02-0E-mail: info@r-biopharm.de
www.r-biopharm.com
Contact us
The R-Biopharm logo and RIDA®GENE are trademarks of R-Biopharm AG.
top related