ret workshop - jma wireless...ret system diagrams 6/7/2019 company confidential 4 aisg sbt enb rf x...

Post on 25-Feb-2020

31 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

connecting the mobile world

RET WORKSHOP

June - 2019

1Company Confidential

Trainer: Vuth Ith

TRAINING OBJECTIVES

Gain knowledge on basic RET Systems Become familiar with Legacy & NWAV RET antennas Understand the testing and troubleshooting of RETs Learn the operation of the JMA RET Controller and GUI

6/7/2019 Company Confidential 2

TRAINING - AGENDA

RET SYSTEM DIAGRAMSANT LABEL & RET DIAGRAMSLEGACY RETS & GUI OPERATIONPRE-TESTING & COMMISSIONINGTROUBLESHOOTINGNWAV RETS & GUI OPERATIONJMA WEBSITE & SUPPORT

6/7/2019 Company Confidential 3

RET SYSTEM DIAGRAMS

6/7/2019 Company Confidential 4

AISG

SBT

eNB

RF

XXXRET

RET

RET

RET w/ Smart Bias Tee

RF

AISG

BBU

XXXRET

RET

RET

CPRI

RRU RRU

RET – RRU

Hybr

id C

able

Hybr

id C

able

SBT

RF

BBU

CPRI

RET Ant-internal SBT - RRU

Hybr

id C

able

Hybr

id C

able

RRU RRUSBT SBT

XXX

RET

SBT SBT

RET

RET

NWAV

DC/AISG through the Feeder/SBT

DC/AISG through AISG cable

DC/AISG through RF Jumper and Internal SBT of ant and RRU

JMA RET ANTENNAs

6/7/2019 Company Confidential 5

2 RETs• X7CAP-665-VR0• QCAP-FRO-656-V

1 RET• X7C-665-VR0• XAP-645-VR0• C7C-FRO-656-VR0 3 RETs

• X7CQAP-665-VR0• C7CQCAP-FRO-656-VR4

JMA ANTENNA & RET LABELs – GEN1

6/7/2019 Company Confidential 6

Ant Serial#

Ant Model#

Ant Info

JMA ANTENNA PORT & RET LABELs – GEN1

6/7/2019 Company Confidential 7

CP Antennas X-Pol Antennas

6/7/2019 Company Confidential 8

RET – 200 TEST DIAGRAM

AISG

Smart Bias-T(Top)

AISG

SBT

eNB

RF

XXX RET

RET

RET

RET w/ Smart Bias Tee

Homerun

BTSANT

AISG

Smart Bias T

(Bottom)

RF

AISG

BBU

XXXRET

RET

RET

CPRI

RRU RRU

RET w/ RRU

Hybr

id C

able

Hybrid CableRET w/ AISG TMA

AISG

eNB

RF

TMA TMA

XXXRET

RET

RET

Smar

t Bia

s-T

(Bot

tom

)

Config #1 Config #2 Config #3

USB Cable

JMA RETCONTROLLER

: Alternate Connections

GUI OPERATION – COM SET UP

6/7/2019 Company Confidential 9

23

4

PCU-1000ATC Lite-200

1

GUI OPERATION – RET-200

6/7/2019 Company Confidential 10

RET ControlRET Info

Ant Info Operator Fields

Device List

Logs

ANTENNA FILE SELECTION – RET-200

6/7/2019 Company Confidential 11

RET Labels

RET-200 – CAL TEST

6/7/2019 Company Confidential 12

Use 17mm open end wrench

NWAV ANTENNA LABEL

6/7/2019 Company Confidential 13

DO NOT REMOVE Factory installed brackets

Ant Serial#Ant Model#

Ant/RET Info

RET UIDs

NWAV ANTENNA NOMENCLATURE

6/7/2019 Company Confidential 14

Tilt Summary

MX08FRO660-02

NWAV - RET & PORT TOPOLOGY

6/7/2019 Company Confidential 15

HEX PORT-One LB ant, 1 RET-Two HB ant, 1 RET

-Two SETS of DC/AISG Bus: LB (RED) & HB (BLUE)-ONLY one DC/AISG connection per path is allowed

OCTO PORT-Two LB ant, 2 RETs-Two HB ant, 1 RET

NWAV – ARRAY TOPOLOGY

6/7/2019 Company Confidential 16

OCTO PORT-Two LB ant-Two HB ant

HEX PORT-One LB ant-Two HB ant

RRU - RET CONNECTION DIAGRAM EXAMPLE

6/7/2019 Company Confidential 17

LB RETs controlled by 700 RRU on Ant1-Port 1 and daisy chained to Ant2 LB AISG Port

HB RET controlled by AWS RRU Ant1-Port 5 HB RET controlled by PCS RRU Ant2 Port5

Low Band:High Band:

6/7/2019 Company Confidential 18

RET CONTROLLER TEST DIAGRAM 1(RF PORT – INTERNAL SBT)

6/7/2019 Company Confidential 19

TEST KITSmart Bias-T

(Bottom)

AISG Cable from RET Controller

¼” Superflex Jumper(DM-4MT)

JMA MX08 ant with SBT-B connected for RET testing at RF Port 1 and 5 (AISG IN)

AISG Pin Connection

RET DC TEST CABLE

6/7/2019 Company Confidential 20

RET CONTROLLER TEST DIAGRAM 2(AISG PORT)

GROUND TESTING & COMMISSIONING

Complete RET Worksheeto Ant Model and S/No Tilt Rangeo RET S/N o Note Sector and Position

Connect RET controller for testingo Commission the RET(s) according to RRU connection diagram – refer to test diagram 1 or 2o Daisy chain as required – Follow RRU connection diagramo Test with RET cables that will be part of the installation

Detailed MOP on RET Controller and GUI operation is available on our website RET Test and Configuration

o Scan to find connected RET(s)o Calibrate RET(s) if status is “Not Calibrated”o Set Tilt per RFDSo Enter configuration data– Date, Installer & Site ID…..o Save RET Report

Note: Remember to use dielectric grease on ALL AISG Ports during the installation process.o AISG Connection – hand tight only!

6/7/2019 Company Confidential 21

SAMPLE RET REPORT

6/7/2019 Company Confidential 22

Text Format

csv Format

SAMPLE RET REPORT

6/7/2019 Company Confidential 23

-Single RET – Type 1-Internally mounted-Not field replaceable

-Confirm the desired tilt per RET worksheet-Verify installation and site info is correct

-UID must be 19 characters-Vendor code “CC” for JMA/CSS

INCORRECT CONNECTION – EXAMPLE 1

6/7/2019 Company Confidential 24

Ant1 Ant2

AISG Cable700 RRU

RF/D

C/AI

SG

AISG Cable – Daisy Chain

JMA RETCONTROLLER

INCORRECT CONNECTION-Multiple DC/AISG connections to LB RETs from RRU and RET Controller-RF Jumper from 700 RRU MUST be disconnected

INCORRECT CONNECTION – EXAMPLE 2

6/7/2019 Company Confidential 25

Ant2

DC/A

ISG

AISG Cable

RF/DC/AISG

RF

AISG

/DC

AISG Cable – Daisy ChainAnt1

RF/D

C/AI

SG

AWS RRUJMA RET

CONTROLLER

INCORRECT CONNECTION-Multiple DC/AISG connections to RETs from RRU and RET Controller-RF Jumper from AWS RRU MUST be disconnected or remove daisy chain cable from LB to HB on Ant2

INCORRECT CONNECTION – EXAMPLE 3

6/7/2019 Company Confidential 26

Ant1 Ant2

700 RRU

RF/D

C/AI

SG

AISG Cable – Daisy Chain

PCS RRU

RF/D

C/AI

SG

RF/D

C/AI

SG

AWS RRU

INCORRECT CONNECTION-Multiple DC/AISG connections to HB RETs from AWS and PCS RRU.-Daisy chain cable from HB MUST be disconnected or put DC Block on either AWS or PCS RRU path.

TROUBLESHOOTING - RET CONTROLLER

6/7/2019 Company Confidential 27

Cannot Discover RETso Ensure the RET controller is the only DC/AISG source to the RET(s)

No RRU connection – refer to Incorrect Connection 1 Check the daisy chain – refer to Incorrect Connection 2

o Verify Com setting is working properly on RET Controller Verify alternating LED for Tx/Rx during the scan Verify all connections are tight

o If using SBT to connect to RF Port Verify SBT connection – refer to Test Diagram1 Check DC/AISG pass thru for all ALDs (multi-band combiners, xplexers) Bypass all ALDs and Isolate

o Verify DC voltage on AISG cable/connector (Pin 6 & 7) JMA RET Controller output is +24VDC Refer to AISG Pin Connection diagram Check for DC voltage on AISG port of Antenna

TROUBLESHOOTING – Cont.

6/7/2019 Company Confidential 28

RET-Actuator Jamo During Calibration

Try the calibration several times Try Resetting the bus and re-calibrating Still Jammed - Contact JMA Tech Support

o During tilt adjustment Verify the RET is Calibrated before setting tilt Try Resetting the bus and re-calibrating Still Jammed - Contact JMA Tech Support

GUI OPERATION - iRET

6/7/2019 Company Confidential 30

JMA WEBSITE & SUPPORT

33

Support Hours Weekday Hours: 8AM to 5PM EST After Hours, Weekend & Holiday Hours:• Via Customer Service Representative (CSR) - 24X7

Phone Support 1-888-201-6073

Email Support & Web Site techsupport@jmawireless.com customerservice@jmawireless.com http://www.jmawireless.com

6/7/2019 Company Confidential

connecting the mobile world

Thank You

Company Confidential 34

top related