Reserve Bank of IndiaHyderabad
Tender Notice.
1. Sealed tenders in two parts are invited for Renovation of Banking Hall, Counters and Back office. The work is estimated to cost approximatelyRs.89.52 lakh and is to be completed within six months.
2. Only those contractors who have minimum 5 years of experience in the field of undertaking similar interior works and civil works have executedtwo or more similar works individually costing not less than Rs.44.79 lakh during last three years and have a minimum yearly turn over of Rs.27lakh (30% of the estimated cost put to the tender) during the last 3 years, will be eligible to tender for the work.
3. The tender forms will be issued only to those contractors who invariably furnish, at the time of applying for purchase of tender forms, the followinginformation in writing/documents to satisfy the Bank about their eligibility for participating in the tendering process.
(a) Composition of the firm Full particulars (whether contractor is an individual, or apartnership firm or a company etc.) Composition of the firm ofcontractors in detail should be submitted along with the namesand addresses of the partners, copy of the Articles ofAssociation/power of Attorney/any other relevant document.
(b) Work experience andcompletion of similar worksof specified value during thespecified period.
Copies of the detailed work orders indicating date of award,value of awarded work, time given for completing the work,etc. and the corresponding completion certificates indicatingactual date of completion and actual value of similar worksexecuted should be enclosed in proof of the work experience.
The details along with documentary evidence of previousexperience, if any, of carrying out works for the Reserve Bankof India at any centre should also be given.
(c) Creditworthiness of thecontractor and their Turnover during the specifiedperiod
Copies of the Income Tax Clearance Certificates/Income TaxAssessment orders along with latest final accounts of thebusiness of the contractor duly certified by a CharteredAccountant should be enclosed in proof of theircreditworthiness and turnover for last three years.
(d) Service Set-up Certificate from the manufacturers/any other valid document insupport of having a full fledged setup at the desired placeshould be enclosed (if required).
(e) Name(s) and address(es) ofthe Bankers and theirpresent contract executives.
Written information about the names and addresses of theirbankers along with full details, like postal addresses, e-mailIds, telephone (landline and mobile) Nos., fax No.etc of thecontact executives (i.e. the persons who can be contacted atthe office of their bankers in case it is so needed) shall befurnished.
(f) Details of bank accounts Full particulars of their bank accounts, like account No., typewhen opened. etc. should be given.
g) Name(s) and address(es) ofthe Clients and their presentcontact executives.
Written information about the names and addresses of theirclients postal addresses, e-mail Ids, telephone (landline andmobile) Nos., fax No. etc. of the contact executive (i.e. thepersons who can be contacted at the office of their clients incase it is need) should be furnished.
h) Details of completed works The client-wise names of work(s), year(s) of execution of
work(s), award and actual costs of executed work(s),completion time stipulated in the contract(s) and actual timetaken to complete the works, names and full contact details ofthe officers/authorities/departments under whom the workswere executed should be furnished.
4, In the event of intending tenderer's failure to satisfy the Bank; the Bank reserves the right to refuse issuance of tender forms/documents to them.
5. Tender forms will be issued from 8-11-2006 to 29-11-2006 on a non-refundable payment of Rs.3,000/- per set by Demand Draft favouring of theRegional Director, Reserve Bank of India, payable at Hyderabad.
6.The tender document can also be downloaded from the Reserve Bank's web site www.rbi.org.in. In case of down loaded documents, the said non-refundable sum of Rs.3,000/- in the form of Demand Draft favouring Reserve Bank of India payable at Hyderabad along with all theinformation/documents, mentioned in para 3 above, will have to be submitted in a sealed cover addressed by name to Shri R.Gandhi, RegionalDirector, Reserve Bank of India, Secretariat Road, Saifabad, Hyderabad upto 3.00 PM on 30-11-2006 for Bank's examination. These sealedcovers shall be opened on the same day for scrutiny. After scrutiny, if any of the contractors is not found to posses the required eligibility, theirtenders will not be opened by the Bank for further processing.
7. Tender in prescribed form shall be submitted in two parts. Part-I tender will contain the Bank's standard technical and commercial conditions forthe proposed work, tenderer's covering letter, tenderers' additional conditions, if any, and the EMD of Rs.1,79,000/- in the form of an irrevocablebank guarantee issued by a scheduled bank in the Bank's standard proforma which is available in the tender form or a demand draft favouringReserve Bank of India payable at Hyderabad and be sealed (in duplicate) in one cover, superscribing "Part - I Tender for Renovation of bankinghall, counters and back office works". Both (Part I and Part II in duplicate) these sealed covers will further be sealed in another envelope addressedby name to Shri R.Gandhi, Regional Director, Reserve Bank of India, Secretariat Road, Saifabad, Hyderabad will be received by the Bank upto 3.00p.m. on30-11-2006 in the manner described in the tenderer form.
8. Part I of the tenders will be opened at 4.00 p.m. on 30-11-2006 in the presence of the authorized representative of the tenerers who choose tobe present. Part II of the tender will be opened on a subsequent date which will be intimated to the tender in advance.
9. The Bank shall obtain reports on past performance of the tenderer from his clients and bankers. The Bank shall evaluate the said reports beforeopening of the Part - II of the tenders. If any tenderer is not found to posses the required eligibility for participating in the tendering process at anypoint of time and/or his performance reports received from his clients and/or his bankers are found unsatisfactory, the Bank reserves the right toreject his offer even after opening of Part I of the tender and his sealed cover containing Part II of the tender along with EMD shall be returned backto him as it is. The Bank is not bound to assign any reason for doing so.
10. The Bank is not bound to accept the lowest tender and reserves the right to accept either in full or in part any tender. The Bank also reservesthe right to reject all the tenders without assigning any reason therefor.
to Banking Hall
Public Entrance
up
Toilets
ENTRANCE
up
Existing Server
Room
EXISTING PAD & DAD WORKSTATIONS
Server
Window
EXISTING
Record Room
up
Security Officer
DAY TO DAY VAULT
8'
(Access for Heavy Cash)
Entrance
Rear Side
waiting
EXISTING Receptionup
FOR D.A.D.BOOK ROOM EXISTING
Access for Heavy Cash
EXISTING
DAY TO DAY VAULT
BOOK ROOMEXISTING
8'-1"
waiting area
Security
3'
18'-212"
3'
312"
10'-8"3"
2'
2'
6'-012"
3"
6'-012"
3"
6'-212"
3"
6'-212"
3"4'-3"
4'-3"
5'-6"
6'-3" 2'
2'-9" 2'
6'-3" 2'
6'-3" 2'
4'-512"
4'-8"
3"
5'-3"
3"
5'-3"
3"
4'-3"
4'-3" 2'
2'
2'-1112"
6'-3"
2'
2'-9"
2'
6'-3"
2'
8'-6"
2'-3"3"
7'-712"
3"
10'
10'
16'
9'-6"
3'-6"
4'-8"
4'
4'-5"
6'
8'
10'
3"
3'
3'
9"
3'
12'-9"
16'-7"
7'-3"
4'
10'
8'-3"8'-3"
15'-6"
7'-2"
8'
10'
10'
6'-1"
2'-9"
3"
2'-9"
6'-112"
3"2'-112"
10'-3"
10'-3"
7'-9"
5'-3"4'-1"
1'-212"
2'
10'-3"
15'-5"
6'
4'-912"
6'-512"3'
5'
RESERVE BANK OF INDIA,HYDERABAD.
DWG NO : BC/RBI/HYD/INT/TENDER/WD-DIM/101-2005.
BUILDING CRAFTS,architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,
Hyderabad -500 029.
consultants -
NOTE:
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
DESIGN DETAILS AND SITE COMPATIBILITY
THE PROBABLE CONTRACTORS SHALL SATISFY
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
CHECKED BY : SANJAY
DRAWN BY : HAKEEM
SHEET TITLE : WORKING DRAWING
DATE : 13th october '2005
INTERIORS OF BANKING HALL OF
PROJECT -
PLEASE DONOT SCALE THE DRAWING,
NOTE :
5' 16'-9"8'-3" 12'-6"
4'
3"
4'
3"
4'
3"
4'
3"
5'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
5'-3"
5'-10"
4'-9"
5'-1"
4'-4"
4'-4"
4'-8"
4'-8"
5'-5"
5'-5 12"
18'
8'
10'-3" 6'-6"
15'-712"
18'-10"
8'-4"
5'-9"
17'-012"
26'-8"
12'-9"
15'-2"
7'-1"
8'-9"
9'-9"
11'-6"
2'-2"
6'-6"
3"
3"
2'-9"
2'-2"
4'-3"
3"
4'-4"
3"
4'-4"
3"
4'-4"
3"
4'-1012"
3"
4'-1012"
3"
4'
2'-6"2'-6"
water body
reception
to Banking Hall
Public Entrance
up
Toilets
up
Existing Server
Room
EXISTING PAD & DAD WORKSTATIONS
switch room
Server
Window
EXISTING
ACCESS
Record Room
CONTROL POINT
up
Security Officer
Counter
Heavy Cash
DAY TO DAY VAULT
8'
(Access for Heavy Cash)
Entrance
Rear Side
waiting
EXISTING Receptionup
FOR D.A.D.BOOK ROOM EXISTING
Access for Heavy Cash
EXISTING
Treasurer
PA to
TREASURER
DAY TO DAY VAULT
BOOK ROOMEXISTING
1Banking Receipts exchange of notes issue of coins Rs 1,2,5
P-1
P-2
P-3
P-4
P-5
D-1
D-2
D-3
D-4
P&D
7'
Coins - 25 & 50 psBanking Paymentsnotes
Defective
Receipt of coins Rs 1,2,5
Exchange of Notes
Upto 500 pcs
Exchange of Notes
Exchange of Notes
Exchange of Notes
Exchange of Notes
DEALERS
Exchange of Notes
Security
DEALERS
Exchange of Notes
CEP
CEP
to Banking Hall
Public Entrance
up
FHP
PB
CP
SPD
WP
FHP
FHP
LHPLHP
FHP
FHP
Existing Server
Room
switch room
FHP
RCP
SCP
CPCPCP
RCPRCPRCP
PBPBPB
LHCPLHCP
FHP
FHPEXISTING
ACCESS
CONTROL POINT
Counter
Heavy Cash
DAY TO DAY VAULT
(Access for Heavy Cash)
Entrance
Rear Side
waiting
EXISTING Receptionup
FOR D.A.D.BOOK ROOM EXISTING
Access for Heavy Cash
CP
RCCP
CEP
CEP
CEP
CEP
LHCP
ICP
ICP
EXISTING
8
10
11
DAY TO DAY VAULT
FGED
FGED
C-4 C-17
C-18
C-19
C-20
C-21
C-22
C-23
C-25
C-24
C-1
C-2
C-26C-27
C-28
C-29
C-30
C-31P-1
P-2
P-3
P-4
P-5
D-1
D-2
D-3
D-4
P&D
RCCP
RCCP
FC FC FC FC
FC
FC
FC
FC
FC
FHP
SPD
SPD
SPD
SPD
SPD
C-32
FCC-33
LHCP
FC FCFC FCFC FCFC FCFC FCFC
C-3 C-6 C-5 C-8 C-7 C-10C-9 C-12C-11 C-14C-13 C-16 C-15
CEP
CEP
CP
PB
PB
LHP
PBPB
PBRCP
RCP
ICP
LHS LHS
R.S
S.T
S.T
T-4
T-2
Treasurer
PA to
TREASURER
T-4
23 4 5 6
7
9
ICP ICP ICP ICP ICP ICP
WP
FHP
LHPFHP
LOW HEIGHT PARTITION
PLANTER BOX
REAR STORAGE UNIT
SIDE TABLE / SIDE STORAGE UNIT
COLUMN PANELLING
WALL PANELLING
VERTICAL DESIGN ELEMENT
LOW HEIGHT CURVED PARTITION
REAR CASH PARTITION-STRAIGHT
FACADE GLAAS ENCLOSURE FOR CASH ENCLOSURE
INTERMEDIATE CASH PARTITION
FACADE GLASS ENCLOSE BETWEEN PAD COUNTERS
SEGRGATION PANEL BETWEEN PAD
FULL HEIGHT PARTITION
TRANSTILE
FULL HEIGHT CURVEDPARTION NEAR MAIN ENTRANCE
LHP
PB
RS
ST
CP
WP
DE
LHCP
RCP
FC
ICP
FGED
SPD
FHP
TT
MEGP
RESERVE BANK OF INDIA,
DAD RUNNING COUNTERSD- 1 TO D-5
PAD RUNNING COUNTERSP- 1 TO P- 6
RUNNING CASH COUNTERSCC-1 TO CC-40
WORK STATIONSW
TABLEST-1 TO T-7
consultants -
HYDERABAD.
Hyderabad -500 029.
Narayanguda,
PH: 040 - 23 22 3049, 98490 16869.
# 3-5-170/A/6/1, First Floor
Lane Adj. Venkateshwara Motors,
architects, engineers & interior designers
DWG NO : BC/RBI/HYD/INT/TENDER/WD/102-2005.
BUILDING CRAFTS,
NOTE:
THEMSELVES WITH THE SITE CONDITIONS AND THE
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THE PROBABLE CONTRACTORS SHALL SATISFY
NOTE :
PROJECT -
PLEASE DONOT SCALE THE DRAWING,
INTERIORS OF BANKING HALL OF
DATE : 27th APRIL '2005
DRAWN BY : SRINIVAS
CHECKED BY : SANJAY
FOLLOW ONLY WRITTEN DIMENSIONS
BEFORE QUOTING FOR THE TENDERS
M/S BUILDING CRAFTS, AND SHALL NOT BE
DESIGN DETAILS SHALL BE FINAL.
DECISSION OF THE ARCHITECTS REGARDING THE
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
COPIED, TRACED, REPRODUCED, MODIFIED
OF THE ARCHITECTS M/s BUILDING CRAFTS.
ANY DISCREPENCY IN THE DRAWING SHALL BE
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
SHEET TITLE : INTERIOR LAYOUT- LEGEND
DESIGN DETAILS AND SITE COMPATIBILITY
FACADE GLASS ENCLOSURE -CURVEDCEP
REAR CASH PARTITION-CURVEDRCCP
LEGEND
SEGREGATION PANEL BETWEEN CASHSPC
5'-6"
18'
65'-3"
41'-812"
17'-012"
13'-3"
10'-4"
10'-3"
C-34
NOTE
COUNTING
WRITING
LEDGE
WRITING
LEDGE
WRITING
LEDGE
ENTRANCE
2'-2"
6'-6"
2'-2"
water body
Reception
8'
PLAN OF PANELLING FOR METAL DETECTOR
3'-4"
1'-10"
ELEVATION OF PANELLINGFOR METAL DETECTOR
6MM PLY WITH 1.5MM
THICK LAMINATE
6MM PLY WITH 1.5MM THICK LAMINATE7'-0"
Metal detector: Panelling for the existing metal detector shall be made using 6mm thick BWR grade plywood(conforming to IS-303 of 1989) on all the visible surfaces both internal and
external and fixed with 1.5mm thick laminate of approved shade and design in lines with the rest
of the design and decor, with necessary surface preparations and hardware, complete for finished
item of work.The item has to be completed in all respects including cost & conveyance of all
materials, labour charges etc complete as directed by the Architect / Banks Engineer .
SIDE ELEVATION OF PANELLING
FOR METAL DETECTOR
7'-0"
1TEM NO.2 OF B.O.Q
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/ENT/103-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,
Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : SRINIVAS
SHEET TITLE :
DATE : 27th APRIL '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
A
4'-4"waiting area
Security
ENTRANCE
KEY PLAN
S.No. AS PER BOQDETAIL DRAWINGS OF
FRONT ENTRANCE DORMA SLIDING
DOOR/PARTITION WITH SIDES
FIXED GLASS (TOUGHENED GLASS)
FRONT ENTRANCE DORMA SLIDING DOOR/PARTITION WITH SIDES FIXED GLASS (TOUGHENED GLASS) : Providing , supplying and Installation of Dorma Automtic sliding
door/partition (exuluding supply of Door operator) made of
10mm thick clear toughened glass fitted to door operator "
ES 90 EC2 " of Dorma- make.The side fixed panel shall be
10mm thick toughened fitted with Dorma corner patch
fittings " PT 90" , "PT 91" and bottom of the glass shall be
inserted into the groove of " U" channel of 25mm which is
inserted into flooring.The Item includes installation of
DORMA ( ES 90 EC2 )Automatic door operator with
complete wiring, fixing with glass panels but excluding
supply of Automatic door operator. Note: All the fitting,
accessories are of DORMA make .
PLAN OF FRONT ENTRANCE DORMA SLIDING DOOR/PARTITION
10 MM THICK FIXED CLEAR TOUGHENED GLASS
5' 8' 5'
ELEVATION AT A
8'-3"
1 (A)
6'-3"
6'-3"
4"
3'-3"
2'
6" SLOT TO BE MADE WITH 12MM PLY FINISHED IN LAMINATE OF
APPROVED SHADE FOR PROVISION OF DRAFTS
LAMINATE FIXED TO 19 MM PLY AS PER SCHEME
LAMINATE OF APPROVED SHADE
BRACKETS IN 1.5"DIA MS PIPE
PLAN OF
WRITING DESK
ELEVATION
2'-2" 2'-2"
2'-2"
2'-2"
4WRITING DESK
1TEM NO.4 OF B.O.Q
WRITING DESK FOR THE
CUSTOMERS: Writing ledge shall be to be made using 19mm thick BWR
Grade Plywood fixed with 1.0mm thick
laminate of approved shade and design as
per the pattern indicated in a combination
of three colors. The writing surface of the
ledge shall at 3'-3" ht made in 18mm thick
BWR Grade Plywood fixed with 1.0mm
thick laminate, edges fixed with 18mm
thick half round beach wood beading duly
polished in melamine finish. Slots for
holding vouchers shall be made above the
writing surface with 12mm thick BWR
Grade Plywood fixed with 1mm thick
laminate on all external exposed surfaces
and all internal surfaces painted in three
coats of enamel paint over lappam finish
with necessary surface preparations.
10 MM THICK FIXED CLEAR TOUGHENED GLASS
DORMA AUTOMATIC
DOOR OPERATOR (ITEM NO.1 B)
FIXED PANEL FIXED PANEL
SLIDING DOOR SLIDING DOOR
PT -90
DORMA CORNER
FITTING
PT -90
DORMA CORNER
FITTING
PT -91 DORMA
CENTER FITTING
PT -90 DORMA CORNER
FITTING
PT -90 DORMA
CORNER
FITTING
PT -90 DORMA
CORNER
FITTING
25MM GROOVE WITH
"U" channel
PANELLING FOR METAL DETECTOR 2
10 MM THICK FIXED CLEAR TOUGHENED SLIDING GLASS DOOR
DETAIL AT A
4"
18MM THICK GRANITE TOP
19MM PLY WOOD BASE
ADDITIONAL 4"WIDE 18MM THICK GRAN'TE
34"34"
Reception Counter : To be made using 19mm thick BWR grade plywood(conforming to IS-303 of 1989) for the structure. The counter shall have dual table
tops from the customer's side . All top surfaces shall be fixed with 18mm thick granite slab
as per the approval of the Architect/Bank's Engineer. Vertical supports shall be given
below the table top at every 4' running length of the counter. The granite tops shall be with
a width of 2'-0" at staff working top at 2'6" height and 1'3" wide at 3'6" height.The granite tops at two levels shall project out of the counter facia by 6". This projection in the granite
slabs shall be supported by 19mm thick BWR grade plywood(conforming to IS-303 of
1989), cut to shape, fixed to the counter. The edge of the granite shall be built up to an
additional thickness of 19mm covering the visible edge of the base plywood top. The
double thicknesss of the granite slabs shall be moulded to shape and design indicated duly polished. All external exposed surfaces of the counter shall be fixed with 1.5mm thick
laminate of approved shade and design, in combination of three colors as per design and all
internal surfaces painted with 1 coat of primer and 2 coats of enamel paint over two coats
of lappam with necessary surface preparations, complete for finished item of work.
Opening has to be provided in the counter at one side with a width of 2' for the access for
staff members. Necessary vertical and horizontal flap door arrangements shall be made for
this portion, camafloaging the access door into the counter. The length at the center of the
counter top only to the extent of the working top shall be considered for measurement
purposes. The length of the open access flap door shall not be considered for measirement.
The item has to be completed in all aspects including cost & conveyance of all materials,
labour charges etc complete as directed by the Architect / Banks Engineer .
SECTION AT X-X'
GRANITE TOP
2'6"
3'-6"
19MM THICK PLYWOOD
KEYBOARD TRAY
CPU RACK
A
19mm PLY WITH 1.5MM LAMINATE
PLAN OF RECEPTION TABLE
6"
GODREJ
STORAGE UNIT
18MM THICKGRANITE
TOP WITH 19MM PLY
WOOD BASE
CPU RACK
EBCO KEYBOARD
TRAY
3'-6"
18MM THICKGRANITE
TOP WITH 18MM PLY
WOOD BASE
19MM THICK PLY
(DOUBLE THICKNESS)
SUPPORT WITH 1.5
THICK LAMINATE
2'-6"3'-6"
19MM PLY VERTICAL
SUPPPORT
HORIZONTAL
FLAP DOOR
19MM THICK PLY
WITH 1.5 THICK
LAMINATE
19MM THICK PLY
WITH 1.5 THICK
LAMINATE
8'-6"
3'
10"2'-2"
A
B
ELEVATION AT AELEVATION AT B
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/RECEPTION/104-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENTLENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : PRASAD
SHEET TITLE :
DATE :16th SEPTEMBER '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
RECEPTION COUNTER 1TEM NO.3
1TEM NO.3 OF B.O.Q
2'1'-3"
Sofas in the Customer area in the Banking Hall : Hard wood
and 18mm ply wood has to be used for the frame structure of the
sofas. Rubber strappings and jute cloth lining above. 4" thick
rubber cushion for the seat and 3" rubber cushion for the back
rest, both with a lining of 12mm thick rubber cushion has to be
ensured. Fabric upholstry shall be of the range Rs 400/- per
meter. Approval has to be taken from the Architects regarding
the final design of the fabric to be used for the sofas.The item has
to be completed in all respects including cost & conveyance of
all materials, labour charges etc complete as directed by the
Architect / Banks Engineer .
7'-5"
4'-6"
7'-5"
4'-6"
7'-5"
4'-6"
2'-7"
1'-9"
PLAN OF SOFA IN BANKING HALL
2'
2'
A A'
FRONT ELEVATION
1'-4"
2'-11"
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/SOFA/105-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENTLENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THEDESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : PRASAD
SHEET TITLE :
DATE :16th SEPTEMBER '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
SOFA IN BANKING HALL 1TEM NO.45
1TEM NO.45 OF B.O.Q
EXISTING COLUMN
NOTE:
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/PAD & DAD COUNTERS/106-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENTLENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THEDESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : RAJSEKHAR
SHEET TITLE :
DATE : 10th SEPTEMBER '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
FACIA ABOVE THE PAD ANDDAD COUNTER TOPS
1TEM NO.7
SEGERAGTION PANELS BETWEEN
PAD AND DAD COUNTERS
1TEM NO.6
A
C
KEY PLAN OF PAD AND DADCOUNTERS
PAD AND DAD COUNTERS 1TEM NO.5
ELEVATION AT C
ELEVATION AT A
9"
2'-4"
2'-6"
1'-3"
3"
1'
1'-6"
412"
12MM THICK GLASS AS PER DESIGN
DOUBLE SKIN PARTITION
MEMBER
1.5MM THICK BLACK COLOUR
LAMINATE
1.5MM THICK DARK COLOUR
LAMINATE
1'-3"
3"
1' 412"
INDEPENDENT GODREJ STORAGE UNIT
GODREJ
SIDE STORAGE UNIT
18 MM THICK
GRANITE TOP
2'-9"
PLAN AT A
6'-0" 6'-0" 6'-0" 6'-0"
6'-0"
PAD & DAD Counters : (Vertical Supports - Double skinned partition, Base Structure - 19mm thick Plywood, Table top - Granite slab, ) The vertical supports beneath the counter top
shall be a double Skined partition, made with a frame work of Boral make 51mm x 35mm metal
studs at 2'-0" c/c for the horizontal members and 51mm x 32mm metal tracks at every 2'-0"c/c for
the verticals with joints staggered to avoid through joints. The frame work shall then be fixed with
6mm thick BWR grade plywood (conforming to IS-303 of 1989) on either sides. All exposed
external surfaces shall be pasted with 1.5mm thick laminate of approved shade and design in
combination of three colors, and internal surfaces to be painted in one coat of primer and two coats
of enamel paint over lappam finish with necessary surface preparations. The necessary provision
for passing of electrical race ways (two Nos) through the partition at skirting level and table top
(bottom) level shall be part of the work.Base structure of the Counter/work stations shall be made
using 19mm BWR grade plywood (conforming to IS-303 of 1989). Additional Vertical supports
shall be provided using 19mm thick plywood under the working top at the chamfered portions to
take additional load of the granite slabs. 18mm thick Granite slab shall be fixed on the top of the
19mm thick plywood (Granite basic price - Rs 130/- per sft) . The edges of the granite slab shall be
bevelled (bull nose) on to the customer's side and half rounded on to the staff side, thoroughly
polished. The staff working top shall be 2'9" wide. The granite slabs on the top shall be in three
pieces cut as per shape of the work stations/ counters and fixed on the base plywood structure with
least visible joints.The counter facia shall be fixed with a trapezium shaped element made using
12mm thick BWR grade plywood(conforming to IS-303 of 1989) fixed with 1.5mm thick laminate
on all external surfaces. Two of such element shall be fixed on facia of either side of each
counter.The item has to be completed in all respects including cost & conveyance of all materials,
labour charges etc complete as directed by the Architect / Banks Engineer . The table working top
area in sft is considered for all measurement purposes.
KEY BOARD TREY
12MM THICK GLASS
AS PER DESIGNitem no 7
5'
MS GRILL
item no 7
MS GRILL
SECTION AT X-X'Segregation privacy panels in between the PAD and DAD counter : To be made as per the circular design (3/4th part of circle and semicircles ) Frame work shall be made using Boral make
51mm x 35mm metal studs at 2'-0" c/c and 51mm x 32mm metal tracks at 2'-0" c/c with joints staggered to
avoid through joints. The rate should also include necessary strengthening with studs / tracks or channels at
openings and bending the frame work as per curvelienar design, fixed with 6mm thick BWR grade plywood
(conforming to IS-303 of 1989) ) on either sides and edge, pasted with interior grade Alluminium Composite
panel, 3mm thick, on all the visible surfaces of the partition. The element shall be fixed on the working top of
the counters. The partition shall have pocket openings of 6"x6" as shown in the drawings, fixed with 8mm
stain glass as per design. The glass shall be inserted into the partition and there shall be no beading for the
glass fixing. The composite panel shall be bent and fixed on the edges of the pockets cut for fixing of the
glass panels to act as beading for holding the glass in place.Care shall be taken to see that no cut edges of
composite panels are visible. The item has to be completed in all respects including cost & conveyance of all
materials, labour charges etc complete as directed by the Architect / Banks Engineer .
Façade glass enclosure above the PAD and DAD counter : Facia above the PAD and DAD counter tops : To be in a combination of MS grill and 12mm thick clear glass . Each counter length shall have two grills
of size 9"x2'4" on either sides fixed on the granite top and supported by the privacy panels (Item No 6) on sides. The
length in between the grills shall be fixed with 12mm thick glass supported by "D" brackets and "L" angles welded to
the extenal frame. The glass shall be in two pieces with intermediate gap of 3" for conversation between the staff and
customers. The bottom glass shall have a segmented arch opening of 1' width and 4.5" height for transaction and the top
edge of the upper glass shall be cut in the curved shape with exposed edges of the glass, mirror polished. The grill shall
be fabricated using 1/2" patty with thickness of 5mm for the frame and the ornamental design inside using 8mm thick
round rods as per design, powdercoated as per the color scheme as suggested by the Architects/ Bank's Engineers,
complete for finished item of work. the grill shall be fixed to the partition and table top using screws and necessary
hardware. Two no.s of grills of size 9"x2'4" shall be welded together with a gap of 3" using MS flat only on the top
edge,shall be fixed in position from the top of segregation panel to attain better fixity and strength.
PAD AND DAD COUNTE
R
item no 5
FACIA
GLA
SS ENCLO
SURE
item no 7
INDEPENDENT GODREJ STORAGE UNIT
Segregation panels (item no 6)
X
X
P-1
P-2
P-3
P-4
P-5
STAINLESS STEEL D-BRACKETWELDED TO M.S GRILL
12MM THICK GLASS FITTED INTO
L-CLAMP AT THE BOTTOM
L-CLAMP WELDED M.S GRILL
12MM THICK GLASS FITTED INTO D-BRACKET
12" M.S PIPE
DETAIL OF GRILL
DETAIL AT B
B
KEY BOARD TREY
X
X'
51mm x 35mm G.I section
6MM PLY WITH 1MM
THICK LAMINATE
DETAIL AT C
ALUMINIUM COMPOSITE PANEL
8MM THICK STAINGLASS
18MM THK GRANITE TOP
TRAPIZODIAL MEMBER
2'-6"
6"
FACADE GLASS MEMBER
51mm x 35mm G.I section
VERTICAL SUPPORT FOR PAD AND DAD COUNTER
3'-10"
3'-10"
7"
C
1TEM NO.5 OF B.O.Q
1TEM NO.6 OF B.O.Q
1TEM NO.7 OF B.O.Q
SEGREGATION PRIVACY
PANEL
ELEVATION AT -C
2'-6"3'-6"
8'-6"
ELEVATION AT -F
GODREJ STORAGE UNIT
EBCO KEYBOARD TRAY INTERMEDIATE 19MM THICK PLY
SUPPORT
8'-6"
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/CASH COUNTERS/107-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,
Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : SRINIVAS
SHEET TITLE :
DATE : 22 nd SEPTEMBER'2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
FACADE POLYARMOUR SHEET
ENSLOURE FOR CASH COUNTERS
STRAIGHT LENGTH.1TEM NO.9
CASH COUNTERS 1TEM NO.8
E'
E
C
B
A
F
KEY PLAN OF CASH COUNTERS
Cash Counters (Both straight and curved length counters) : (Vertical Supports - Double skinned partition, Base Structure - 19mm thick Plywood, Table top (dual top) - Granite slab ) The front side vertical support (upto height of 3'6") beneath the counter top shall be a double Skined partition, made with a frame work of Boral make 51mm x 35mm metal studs at 2'-0" c/c for the horizontal members and 51mm x 32mm metal tracks at
every 2'-0"c/c for the verticals with joints staggered to avoid through joints. In case of vertical support for the curved counters, horizontal frame work shall be using 2.5" wide planks of 35mm thick WWR Grade-2 MDF board
(conforming to IS-12406 of 2003)(double thickness) cut to shape in the curvilenear pattern of the partition and the verticals shall be same as mentioned above. The frame work shall then be fixed with 6mm thick BWR grade
plywood (conforming to IS-303 of 1989) on either sides. All exposed external surfaces shall be pasted with 1.5mm thick laminate of approved shade and design in combination of three colors, and internal surfaces to be painted in
one coat of primer and two coats of enamel paint over lappam finish with necessary surface preparations. The necessary provision for passing of electrical race ways (two Nos) through the partition at skirting level and table top
(bottom) level shall be part of the work. The Running counter shall have dual tops, one at 2'6" height from the staff side and one at 3'6" at the customer's side. Base structure of the Counter shall be made using 19mm thick BWR
grade plywood (conforming to IS-303 of 1989). The vertical supports shall be positioned as per the counter layout and additional supports usnign 18mm thick plywood shall be provided in between the counter length where ever the
individual counter length exceeds 4' length. 18mm thick Granite slab shall be fixed on the top of the counter at both 2'6" height and 3'6" height. (Granite basic price - Rs 130/- per sft). The staff working top shall be 2'9" wide and the
customer top shall be 1'6" wide with a slit opening in the center of each counter fixed with plain glass for enabling vision of cash counting for the customers. The edges of the granite slab shall be bevelled (bull nose) on to the
customer's side and half rounded on to the staff side, thoroughly polished. Both the granite tops shall be supported by 18mm thick BWR grade plywood(conforming to IS-303 of 1989) as base. The counter facia shall be fixed with a
trapezium shaped element made using 12mm thick BWR grade plywood. Two of such element shall be fixed on facia of either side of each counter. Openings of size 1'6" x 9" shall be made in the vertical support partition in
between the customer and the staff working top surfaces to enable cash transaction with pivoted tray arrangement. Necessary additional supports at the edges and required arrangements for fixing of pivots shall be part of the job. All
external exposed surfaces shall be fixed with 1.5mm thick laminate, and all internal surfaces to be painted in one coat of primer and two coats of enamel paint over lappam finish with necessary surface preparations .The item has to
be completed in all respects including cost & conveyance of all materials, labour charges etc complete as directed by the Architect / Banks Engineer .
Facade Polycarbonate sheet Enclosure for the Cash Counters:Facade Polyarmour sheet enclosure for the cash counters in the Straight length : Design, Fabrication and Installation of POLYARMOUR facades for cash counters using LEXAN Margard sheet of 6mm thick,silicon hard coated and abrasion
resistant. The sheet shall be bent to shape by Cold Bending as per the angle indicated in the drawing and fixed with BURGLAR Resistant Polyklad Aluminum
Section of WICTEC 13502 A/ WICTEC 135024 section of size 50mm x 50mm x 2mm (alluminium dry glazing), bent to shape of the facade, with metal spacer duly
powder coated and fitted to table top counters with necessary brackets and hardware. The sheets shall be fixed using pressure plate using Cold Forged Self Drilling
Screws with washers. The bottom piece shall stand vertically above the customer top of the counter till a height of 1'6" and top portion of sheet shall be inclined
towards staff area to reach a height of 8'-6" as indicated in the drawing.The frame work shall be made on the facade using Burglar resistant facades of WICTEC
13502 A/ WICTEC 135024 of poly clad structural 1002 of size 50mm x 50mm x 2mm, and fixed to the edge face of the intermediate partitions between the cash
counters and segregation panels within the counters. Sections shall be fixed to counter and to the partition using screws and necessary hardware.The bottom edge of
polycarbonate sheets shall run in a aluminium extrusion of poly clad structural 1002 section of WICTEC 135021 of size 31.5mmx50mm, fixed horizontally along
the length of edge of polycarbonate sheet above the counter top surface, duly making a groove inside the top 18mm thick plywood member at 3'-6" height. The
granite slabs with the width of 1'-6" to be placed on the customer top shall be cut into 2 pieces and fixed on the plywod counter top from either side of the
polycarbonate sheet sturcture. All the Aluminium sections shall be powder coated (matt finish).Resistance has be attained as per Class-3 of DIN V ENV 1627 via.
additional safety measures in transom profile , satefy parts in pressure profiles and by screwing through the first cavity of mullion profiles. Construction depth shall
be in accordance with WICTEC 50/60 standard facades.The item has to be completed in all respects including cost & conveyance of all materials, labour charges etc
complete as directed by the Architect / Banks Engineer .
1TEM NO.8 OF B.O.Q
1TEM NO.9 OF B.O.Q
PLAN OF CASH COUNTERS (typical)
FACADE GLASS ENCLOSURE FOR CASH
item no 9
8'-6" 8'-6"
2'-6"
1'-6"
3'9"
3'-6"
1'
Falseceiling level in the customer area
Falseceiling level in the cash counters
SECTION OF CASH COUNTER AT "XX"
6mm POLYCARBONATE SHEETFOR THE COUNTER FACADE
SECTIONAL ELEVATION AT "YY"
3'
1' 1'
1'-9"5' 3'-6"
INTERMEDIATE PARTITION BETWEEN COUNTERS
8'-6"
8MMTHICK
FLOAT GLASS (ETCHED)
6MM PLY WOOD BOARD WITH 1.5 MM LAMINATE2'-6"
2'-9"
3'-6"
1'
FACADE EN
CLO
SURE
INTERMEDIATE PRIVACY PANELS BETWEEN THE COUNTERS
3'
1Banking Receipts
3 4exchange of notes
5issue of coins Rs 1,2,5
Coins - 25 & 50 psBanking Payments notesDefective
DOUBLE SKIN PARTION
ABOVE POLYARMOUR
FACADE
6MM THICK POLYCARBONATE SHEETINCLINED TOWARDS STAFF AREA
18MM THICK GRANITE TOP FIXED OVER 19MM THICK PLY WOOD BASE
PROJECTED TRAPEZIUM SHAPED ELEMENT
6MM THICK BWR GRADE PLY WITH
1.5 MM LAMINATE OF APPROVED SHADE
2'-6"
DROP IN FALSE CEILING
False ceiling level in the
cash counters
Falseceiling level in the customer area
4'
3"
4'
3"
4'
3"
4'
3"
5'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
10'
6'-6"
3'-6"1'-6"
5'
8'-6"
3'-6"
6'-9"
4'
ELCTRICAL RACE WAY AT SKIRTING LEVEL
FACADE PO
LYARMOUR
PARTITION-CASH
COUNTE
RS
Item No: 9
CASH
COUNTE
R
item no 8
CASH
COUNTE
R
WICTEC 50 EH/60EH STANDARD FACADEIN ALUMINIUM POWDER COATED
WICTEC 50 EH/60EH STANDARD FACADEIN ALUMINIUM POWDER COATED
WICTEC 50 EH/60EH STANDARD FACADEIN ALUMINIUM POWDER COATED
6mm THICK POLYCARBONATE SHEETFOR THE COUNTER FACADE
6mm THICK POLYCARBONATE SHEET FOR THE COUNTER FACADE
5'
6"
2'-6"
Ø5'
EPDM RUBBER GASKET
TWIN LIP EPDM RUBBER GASKET
2NO.S OF 3MM THK FORMABLE MARGARD SHEET
FOR CURVED FACADE/
1NO.S OF 6MM THK MARGARD SHEET FOR
STRAIGHT LENGTH.
Metal SPACER
COLD FORGED SELF DRILLING SCREW
KEY PLAN OF CASH REAR PARTITION
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/REAR CASH PARTITION/108-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,
Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : HAKEEM
SHEET TITLE :
DATE : 11th SEPTEMBER '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
1TEM NO.12
REAR SIDE PARTITION BEHIND
CASH COUNTERS-STRAIGHT
1TEM NO.11
Rear side partition behind the cash counters
(Curved length ): The partition shall be in a combination of opaque and transparant surfaces.The opaque
surfaces shall be made with using To be made using Boral
make 51mm x 35mm metal studs at 2'-0" c/c and 51mm x
32mm metal tracks at 2'-0" c/c with joints staggered to avoid
through joints in curved shape of partition. The rate should
also include necessary strengthening with studs / tracks or
channels at openings and bending the frame work as per
curvelienar design , fixed with 6mm thick flexi ply on the
either sides pasted with 1.5mm thick laminate of approved
shade and design in a combination of three colors.The
transparant surfaces shall be fixed with 8mm thick curved
glass pasted with sticker of etching/frosted design. Frame
work shall be made so as to accommodate wooden beading
design on the ends of partition length of each counter (cabin)
with a width of 1'3". Beachwood beading of size 3/4"x3/4"
shall be fixed on either sides as per design .The shutters for
the partitions shall be 35mm thick BWR flush shutters, with a
opening for clear 6mm thick glass in the center as shown in
the drawings.The sticker of etching design shall be fixed on
the glass as per specified design. The edge of the opaque
surfaces shall be fixed with 12mm thick beech wood beading
and polished in melamine finish. All accessories like the
Hardwyn (gazel) door closer, door stopper , hinges, godrej
night latch etc, shall be part of the job. Including cost &
conveyance of all materials, labour charges etc complete as
directed by the Architect / Banks Engineer or finished item of
work as per drawing .
PLAN OF REAR CASH PARTITION
Rear side partition behind the cash counters (Straight length ):The partition shall be in a combination of opaque and transparant surfaces. The opaque surfaces shall be made with Boral make 51mm x 35mm metal studs at every 2'-0" c/c and 51mm x 32mm metal tracks at every 2'-0" c/c with
joints staggered to avoid through joints. The vertical members should touch the ceiling with horizontal ceiling channel at slab / beam bottom. The rate should
also include necessary strengthening with studs / tracks or channels at doors and other openings, fixed with 6mm thick BWR grade plywood(conforming to
IS-303 of 1989) on the either sides fixed with 1.5mm thick laminate of approved shade and design in a combination of three colors.The transparant surfaces
shall be fixed with 8mm thick toughned glass pasted with sticker of etching/frosted design. Frame work shall be made so as to accommodate wooden beading
design on the ends of partition length of each counter (cabin) with a width of 1'3". Beachwood beading of size 3/4"x3/4" shall be fixed on either sides as per
design .The shutters for the partitions shall be 35mm thick BWR grade flush doors, with a opening for clear 6mm thick glass in the center as shown in the
drawings. The sticker of etching design shall be fixed on the glass as per specified design. The edge of the opaque surfaces shall be fixed with 12mm thick
beech wood beading and polished in melamine finish. All accessories like the Hardwyn (gazel) door closer, door stopper , brass hinges, godrej night latch etc,
shall be part of the job. Including cost & conveyance of all materials, labour charges etc complete as directed by the Architect / Banks Engineer or finished
item of work as per drawing .
REAR SIDE PARTITION BEHIND
CASH COUNTERS-CURVED
1TEM NO.11 OF B.O.Q
1TEM NO.12 OF B.O.Q
A
B
112" X 12" THICK BEECH
WOOD BEADING
1'
112" X 12" THICK BEECH
WOOD BEADING
6MM PLY WITH 1.5 MM THICK LAMINATE
35MM FLUSH DOOR WITH 1.5 MM THICK LAMINATE
8MM THICK TOUGHENED GLASS
112" X 12" THICK BEECH
WOOD BEADING6MM THICKGLASS
8'-6"7'
2'-6"
5'-9"1'
ELEVATION OF REAR CASH PARTITION AT -A
6MM PLY WITH 1.5 MM THICK LAMINATE
35MM FLUSH DOOR WITH 1.5 MM THICK LAMINATE
112" X 12" THICK BEECH
WOOD BEADING6MM THICKGLASS
8MM THICK CURVED GLASS
8'-6"7'
PLAN OF REAR CURVED CASH PARTITION
ELEVATION OF REAR CURVED CASH PARTITION AT -B
2'-6"
5'-9"
5'-6"
8'-7"
2'
7'-8" 2'-9" 4'-7"
2'2'2'
4'-8" 2'-9" 2'-9" 2'-6" 2'-9" 2'-4"
2' 1'-5"
2'-9" 5'-412"
2'-9"2'-9"
7'-8"
2'-6"
5'-9"
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/INERMEIDATE PANEL/109-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENTLENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : SRINIVAS
SHEET TITLE :
DATE : 12th SEP '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
ITEM NO.8CASH COUNTERS
FACADE POLYARMOUR SHEET ENCLOSURE
FOR THE CASH COUNTERS(CURVED LENGTH) 1TEM NO.10
INTERMEDIATE PARTITIONS
BETWEEN CASH COUNTERS1TEM NO.15
INTERMEDIATE PRIVACY PANELS
IN BETWEEN THE CASH COUNTERS 1TEM NO.13
KEY PLAN OF CASH COUNTERS
ELEVATION OF CURVED CASH COUNTER AT -B
3mm+3mm thick polycarbonate sheet
18MM THICK GRANITE TOP
TRAPEZIUM SHAPED ELEMENT
2'-6" 19MM THICK PLY WITH 1.5 MMLAMINATE OF SHADE
3'-6"
PLAN OF CURVED CASH COUNTER AT- B
18MM THICK GRANITE TOP
INTERMEDIATE PARTITION
BETWEEN COUNTERS
SEGREGATION PRIVACY PANELBETWEEN CASH COUNTERS
CASH
COUNTE
R
Facade Polyarmour sheet Enclosure for the Cash Counters(Curved Length) : Design, Fabrication and Installation of POLYARMOUR facades for cash counters using two sheets of LEXAN Formable
Margard sheets of 3mm+3mm double thickness with spacer, silicon hard coated and abrasion resistant. The sheet shall be bent to shape by Cold Bending as per the curvature indicated in the drawing along the
length of running counter and fixed with BURGLAR Resistant Polyklad Aluminum Section of WICTEC 13502 A/ WICTEC 135024 section of size 50mm x 50mm x 2mm (alluminium dry glazing), bent to
shape of the facade, with metal spacer duly powder coated and fitted to table top counters with necessary brackets and hardware. The sheets shall be fixed using pressure plate using Cold Forged Self Drilling
Screws with washers. The frame work of the facade shall be made using Burglar resistant facades of WICTEC 13502 A/ WICTEC 135024 of poly clad structural 1002 of size 50mm x 50mm x 2mm, and fixed
to the edge face of the intermediate partitions between the cash counters and segregation panels within the counters. Sections shall be fixed to counter and to the partition using screws and necessary
hardware.The bottom edge of polycarbonate sheets shall run in a aluminium extrusion of poly clad structural 1002 section of WICTEC 135021 of size 31.5mmx50mm bent to shape of the curve of the counter,
fixed horizontally along the length of edge of polycarbonate sheet above the counter top surface, duly making a groove inside the top 18mm thick plywood member at 3'-6" height. The granite slabs with the width
of 1'-6" to be placed on the customer top shall be cut into 2 pieces and fixed on the plywod counter top from either side of the polycarbonate sheet sturcture. All the Aluminium sections shall be powder coated
(matt finish).Resistance has be attained as per Class-3 of DIN V ENV 1627 via. additional safety measures in transom profile , satefy parts in pressure profiles and by screwing through the first cavity of mullion
profiles.Construction depth shall be in accordance with WICTEC 50/60 standard facades.The item has to be completed in all respects including cost & conveyance of all materials, labour charges etc complete as
directed by the Architect / Banks Engineer .
Cash Counters :(Vertical Supports - Double skinned partition, Base Structure - 19mm thick Plywood, Table top (dual top) - Granite slab ) The front side vertical support (upto height of 3'6") beneath the counter top shall be a double Skined partition, made
with a frame work of Boral make 51mm x 35mm metal studs at 2'-0" c/c for the horizontal members and 51mm x 32mm metal tracks
at every 2'-0"c/c for the verticals with joints staggered to avoid through joints. In case of vertical support for the curved counters,
horizontal frame work shall be using 2.5" wide planks of 35mm thick WWR Grade-2 MDF board (conforming to IS-12406 of
2003)(double thickness) cut to shape in the curvilenear pattern of the partition and the verticals shall be same as mentioned above.
The frame work shall then be fixed with 6mm thick BWR grade plywood (conforming to IS-303 of 1989) on either sides. All
exposed external surfaces shall be pasted with 1.5mm thick laminate of approved shade and design in combination of three colors, and
internal surfaces to be painted in one coat of primer and two coats of enamel paint over lappam finish with necessary surface
preparations. The necessary provision for passing of electrical race ways (two Nos) through the partition at skirting level and table top
(bottom) level shall be part of the work. The Running counter shall have dual tops, one at 2'6" height from the staff side and one at
3'6" at the customer's side. Base structure of the Counter shall be made using 19mm thick BWR grade plywood (conforming to IS-303
of 1989). The vertical supports shall be positioned as per the counter layout and additional supports usnign 19mm thick plywood shall
be provided in between the counter length where ever the individual counter length exceeds 4' length. 18mm thick Granite slab shall
be fixed on the top of the counter at both 2'6" height and 3'6" height. (Granite basic price - Rs 130/- per sft). The staff working top
shall be 2'9" wide and the customer top shall be 1'6" wide with a slit opening in the center of each counter fixed with plain glass for
enabling vision of cash counting for the customers. The edges of the granite slab shall be bevelled (bull nose) on to the customer's side
and half rounded on to the staff side, thoroughly polished. Both the granite tops shall be supported by 19mm thick BWR grade
plywood(conforming to IS-303 of 1989) as base. The counter facia shall be fixed with a trapezium shaped element made using 12mm
thick BWR grade plywood. Two of such element shall be fixed on facia of either side of each counter. Openings of size 1'6" x 9"
shall be made in the vertical support partition in between the customer and the staff working top surfaces to enable cash transaction
with pivoted tray arrangement. Necessary additional supports at the edges and required arrangements for fixing of pivots shall be part
of the job. All external exposed surfaces shall be fixed with 1.5mm thick laminate, and all internal surfaces to be painted in one coat
of primer and two coats of enamel paint over lappam finish with necessary surface preparations .
SECTIONAL ELEVATION AT E-E' DETAIL OF SEGREGATION PRIVACYPANELS IN BERTWEEN CASH COUNTERS
3MM THICK ALLUMINIUM
COMPOSITE PANELOVER 6MM
THICK PLY WOOD
Segregation privacy panels in between the Cash counters (out side the cash counters on the customer side) : To be made as per the circular design (3/4th part of circle or semi circles ) Frame work shall be made using Boral make 51mm x 35mm metal
studs at 2'-0" c/c and 51mm x 32mm metal tracks at 2'-0" c/c with joints staggered to avoid
through joints . The rate should also include necessary strengthening with studs / tracks or
channels at openings and bending the frame as per curvelienar design, fixed with 6mm
thick BWR grade plywood (conforming to IS-303 of 1989) ) on either sides and edge,
pasted with interior grade Alluminium Composite panel, 3mm thick, on all the visible
surfaces of the partition. The element shall be fixed on the working top of the counters.
The partition shall have pocket openings of 6"x6" as shown in the drawings, fixed with
8mm stain glass as per design. The glass shall be inserted into the partition and there shall
be no beading for the glass fixing. The composite panel shall be bent and fixed on the
edges of the pockets cut for fixing of the glass panels, complete for finished item of
work.Care shall be taken to see that no cut edges of composite panels are visible. The item
has to be completed in all respects including cost & conveyance of all materials, labour
charges etc complete as directed by the Architect / Banks Engineer .
DETAIL OF INTERMEDIATE PARTITION
Intermediate partitions in between the cash counters : To be made using Boral make 51mm x 35mm metal studs at 2'-0" c/c and 51mm x 32mm metal
tracks at 2'-0" c/c with joints staggered to avoid through joints. The rate should also
include necessary strengthening with studs / tracks or channels at openings, fixed with
6mm thick BWR grade plywood(conforming to IS-303 of 1989) on either sides pasted
with 1.5mm thick laminate of approved shade and design in combination of three colors
as per design. Openings for the glass panels shall be made as per design in the partition
and 8mm thick clear glass pasted with sticker of etching/frosted design shall be fixed in
position. Beachwood beading of 1/2" thickness shall be used to fix the glass panels,
polished in melamine finish.The item has to be completed in all respects including cost
& conveyance of all materials, labour charges etc complete as directed by the Architect
/ Banks Engineer .
SEGREGATION PRIVACY PANEL BETWEEN CASH COUNTERS
1TEM NO.14
1TEM NO.10 OF B.O.Q
1TEM NO.15 OF B.O.Q 1TEM NO.13 OF B.O.Q
1TEM NO.16 OF B.O.Q
DETAIL OF INTERMEDIATE PRIVACY PANEL
Intermediate privacy panels in between the cash counters
(inside the cash counters) : The Frame work shall be made using Boral make 51mm x 35mm metal studs at 2'-0" c/c and 51mm x 32mm metal tracks at 2'-0" c/c with joints
staggered to avoid through joints. The rate should also include necessary strengthening with studs
/ tracks or channels at openings and bending the frame work as per curvelienar design, fixed with
6mm thick BWR grade plywood (conforming to IS-303 of 1989) on either sides pasted with
1.5mm thick laminate of approved shade and design. These panels shall be fixed on the granite
surface of the cash counter at the bottom and anchored to the intermediate partitions between the
cash counters at the false ceiling level to attain fixity and strength. These panels shall have
provision for fixing the vertical and inclined polycarbonate sheet facade box sections, of the cash
counters on the sides. The surface area of the panel shall be considered for all measurement
purposes. The item has to be completed in all respects including cost & conveyance of all
materials, labour charges etc complete as directed by the Architect / Banks Engineer .
3'-6"
5'
8'-6"
1TEM NO.8 OF B.O.Q
S.No. AS PER BOQDETAIL DRAWINGS OF
8'-6" 8'-6"
2'-6"
1'-6"
3'9"
3'-6"
1'
Falseceiling level in the customer area
Falseceiling level in the
cash counters
2'-6"
PVC ELCTRICAL RACE WAY
AT SKIRTING LEVEL
8'-9" 8'-6"
2'-6"
1'-6"
3'9"
3'-6"
1'
Falseceiling level in the
customer areaFalseceiling level in the
cash counters
DROP IN FALSE CEILING
2'-6"
PVC ELCTRICAL RACE WAY AT SKIRTING LEVEL
INTERMEDIATE PARTITION
BETWEEN COUNTERS
SEGREGATION PRIVACY PANELBETWEEN CASH COUNTERS
8'-6"
6MM PLY WOOD BOARD
WITH 1.5 MM LAMINATE2'-6"
2'-9"9"
1'
3'
2'-6"Falseceiling level in the
cash counters
Falseceiling level in the
customer area
STAIN GLASS
6'-9"
4'
WICTEC 50 EH/60EH STANDARD FACADE
IN ALUMINIUM POWDER COATED
WICTEC 50 EH/60EH
STANDARD FACADEIN ALUMINIUM POWDER COATED
E'
E
C
B
A
F
5'
2'-6"
5'
DOUBLE SKIN PARTION
ABOVE POLYARMOUR
FACADE
STAIN GLASS
6"
5'
4' 8MM THICK FLOAT
GLASS (ETCHED)
6MM THICK PLY WITH
1.5MM THICK LAMINATE
DOUBLE SKIN PARTION
ABOVE POLYARMOUR
FACADE
8MM THICK FLOAT
GLASS (ETCHED)
INTERMEDIATE PRIVACY PANELBETWEEN COUNTERS
2'-6"
2'-6"
2'-6"
2'-6"
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/PARTITIONS/110-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,
Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : SRINIVAS
SHEET TITLE :
DATE : 17th SEP '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
FULL HEIGHT PARTITONS 1TEM NO.16
LOW HEIGHT CURVED
HEIGHT PARTITONS1TEM NO.17
Full height partitions in the back office area: To be made using Boral make 51mm
x 35mm metal studs at every 2'-0" c/c and 51mm x 32mm metal tracks at every 2'-0"
c/c with joints staggered to avoid through joints. The vertical members should touch
the ceiling with horizontal ceiling channel at slab / beam bottom. The rate should lso
include necessary strengthening with studs / tracks or channels at doors and other
openings, fixed with 6mm thick BWR grade plywood (conforming to IS-303 of 1989)
on either sides pasted with 1.5mm thick laminate of approved shade and design in
combination of three colors as per design. Openings for the glass panels shall be made
as per design in the partition and 8mm thick glass shall be fixed in position.The
shutters for the partitions shall be 35mm thick BWR flush shutters, with a opening for
clear 6mm thick glass in the center as shown in the drawings.The sticker of etching
design shall be fixed on the glass as per specified design. The edge of the opaque
surfaces shall be fixed with 12mm thick beech wood beading and polished in
melamine finish. All accessories like the Hardwyn (gazel) door closer, door stopper ,
hinges, godrej night latch etc, shall be part of the job. Including cost & conveyance of
all materials, labour charges etc complete as directed by the Architect / Banks
Engineer or finished item of work as per drawing.
TYPICAL ELEVATION OF FULL HEIGHT PARTITION
8'-6"7'
4'
Low height Curved partitions in the Customer area: To be made as per
curvelinear design using Boral make 51mm x 35mm metal studs at 2'-0" c/c and
51mm x 32mm metal tracks at 2'-0" c/c with joints staggered to avoid through
joints. The rate should also include necessary strengthening with studs / tracks or
channels at openings and bending the frame work as per curvelienar design, pasted
with 1.5mm thick laminate of approved shade and design in a combination of three
colors on all the visible surfaces of the partition. The partition shall be fixed to the
floor and the adjacent columns. The partition shall have pocket openings of 6"x6"
as shown in the drawings, fixed with 8mm thick stain (multi-colored) glass as per
design. The glass shall be inserted into the partition and there shall be no beading
for the glass fixing. The laminate shall be fixed on the edges of the pockets cut for
fixing of the glass panels. The visible edges of the partition shall be fixed with
beachwood beading cut to shape and curve on the top and the vertical edges of the
partition, projecting out by 1/2" on either sides, polished in melamine finish,
complete for finished item of work.The item has to be completed in all respects
including cost & conveyance of all materials, labour charges etc complete as
directed by the Architect / Banks Engineer .
PLAN OF LOW HEIGHT PARTITION-CUSTOMER AREA
False ceiling level
suspended false ceiling
Suspended Ceiling Design element in front of the cash counters : To be made with a
frame work of 18mm thick BWR grade plywood (conforming to IS-303 of 1989) for the
verticals at a grid of 1'6"x1'6" and a height of 6". The bottom edge of the plywood shall be cut
in the shape of a curve as shown in the drawings, and 8mm thick flexi-plywood shall be fixed
to the plywood frame box structure from below. The flexi-ply shall then be fixed with 3mm
thick alluminium composite panel - interior grade along the curved pattern with the required
groove pattern as per design. Necessary openings shall be made for inclusion of spot lights in
the bottom sheets. The upper surfaces shall be painted with one coat of primer and two coats of
enamel paint over two coats of lappam with necessary surface preparations. The design
suspended element thus made shall be suspended from the existing roof slab using chain link.
The visible length of the chain link below the false ceiling shall be with 8mm diameter SS
pipes, complete for finished item of work.The item has to be completed in all respects
including cost & conveyance of all materials, labour charges etc complete as directed by the
Architect / Banks Engineer .
SUSPENDED FALSE CEILING ELEMENT 1TEM NO.32
FALSE CEILING ELEMENTDETAIL OF SUSPENDED
1TEM NO.16 of B.O.Q
1TEM NO.17 of B.O.Q
1TEM NO.32 of B.O.Q
6"x6"STAIN GLASS
6MM PLY FIXED WITH 1.5 MM LAMINATE
4' 2.5"DOUBLE THICKNESS
35 MM THICK MDF BOARD
FRAME WORK
6MM THICK FLEXI PLY
WITH 1MM LAMINATE
100MM X 12MM THICK
BEACH WOOD BEADING
7'-3"
FRONT ELEVATION SECTION
DETAIL AT A
6"
6"
6MM PLY WITH
1.5 MM LAMINATE
8MM THICK GLASS
4'-2"
4'-4"
STICKERING AS PER DESIGN
51mm x 35mm G.I section
6MM PLY WITH 1MM
THICK LAMINATE
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/TABLES/111-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENTLENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THE
DESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : PRASAD
DATE : 03th MAY '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
REAR ELEVATION OF TABLEFRONT ELEVATION OF TABLE SIDE ELEVATION OF TABLES
SECTIONAL ELEVATION OF TABLES
19MM THICK PLY WITH 1.5 MM
THICK MOTHER COLOUR LAMNIATE OF APPROVED SHADE
25 MM POSTFORMED TABLE TOP
WITH A THICKNESS OF 35MM AT EDGES WHICH SHALL BE BEVELLED.
19MM RAISED SURFACE OVER FRONT FACADE OF TABLE WITH 1.5MM BI-COLOR LAMINATE OF
APPROVED SHADE
1.5MM BLACK COLOUR LAMINATE SKIRTING
2'-6"
3"
1'-2"
1'-7"
SPACE FOR BELOW STORAGE UNIT
19 MM THICK PLY WITH ENAMEL PAINT
SPACE FOR CCPU RACK BELOW TABLE
25 MM POSTFORMED TABLE TOP
INTERNAL EXPOSED SURFACE FINISHED SYNTHETIC ENAMEL PAINT
POWDER COATED EBCO COMPUTER KEYBOARD TRAY
25 MM POSTFORMED TABLE TOP
SPACE FOR CPU RACK
POWDER COATED EBCO COMPUTER KEYBOARD
2'-6"
19MM THICK PLY WITH 1.5 MM LAMINATE
19MM THICK PLY WITH 1.5 MM LAMINATE
Tables: Providing and fixing of tables of different sizes as per the positions indicated
in the drawing. The table top shall be made using 25mm thick WWR Grade-2 MDF board (conforming to IS-12406 of 2003) postformed with 0.6mm thick postformation
laminate, with bull nosed profile along the edge of the table top. The bottom verticals
shall be made using 19mm thick BWR grade plywood (conforming to IS-303 of
1989) with all external surfaces fixed with 1.5mm thick laminate of approved shade
and design in combination of three colors as per design and all internal surfaces
painted with one coat of primer and two coats of enamel paint over two coats of
lappam with necessary surface preparations. The table top shall be fixed to the bottom
structure by using "L" angles in GI, using standard hardware.The item has to be
completed in all respects including cost & conveyance of all materials, labour charges
etc complete as directed by the Architect / Banks Engineer .
PLAN OFTABLE T-2
3'-0"6"
3"
PLAN OFTABLE T-5
5'-6"
2'-6"
6"
3"
SHEET TITLE :
S.No. AS PER BOQDETAIL DRAWINGS OF
1TEM NO.19
1TEM NO.18 OF B.O.Q
19MM THICK PLY WITH 1.5 MM LAMINATE
4'
6MM PLY FIXED WITH 1.5 MM LAMINATE4' GI SECTION
6MM THICK PLY
WITH 1MM LAMINATE
100MM X 12MM THICK
BEACH WOOD BEADING
FRONT ELEVATION OF LOW HT PARTITION IN BACKOFFICE
SECTION
100MM X 12MM THICK
BEACH WOOD BEADING
6MM THICK PLY
WITH 1MM LAMINATE
GI 51MM X32MM METAL TRACK
A
DETAIL AT A
Low height partitions in back office:Low height partition shall made using Boral make 51mm x 35mm metal studs
at 2'-0" c/c and 51mm x 32mm metal tracks at every 2'-0"c/c with joints staggered to avoid through joints. The rate
should also include necessary strengthening with studs / tracks or channels at openings, fixed with 6mm thick BWR
grade plywood (conforming to IS-303 of 1989) on either sides pasted with 1.5mm thick laminate on external exposed
side of approved shade and design in combination of three colors as per design. The visible edges of the partition shall be fixed with beachwood beading of sectional size 4"x 1/2" on the top and the vertical edges of the partition,
projectiong out by 1/2" on either sides, polished in melamine finish. Required provisions for the electrical cabling has
to be provided within the partitions. The partitions adjoining the work stations shall be provided with soft board fixed
with upholstry (basic price Rs 150/ per meter) and a white writing board of size 2' x 1'6" has to be provided for each
work station.The item has to be completed in all respects including cost & conveyance of all materials, labour charges
etc complete as directed by the Architect / Banks Engineer.
1TEM NO.19 OF B.O.Q
1TEM NO.18
TABLES (2&5)
LOW HEIGHT PARTITIONS IN
BACK OFFICE
25 MM POSTFORMED TABLE TOP
9'
PLAN OF TABLE FOR
PASTING SOLID NOTES
3'
2'
3'
FRONT ELEVATION
3'
2'-6"
REAR ELEVATION
19MM THICK PLY WITH 1.5 MM LAMINATE
18MM THICK GRANITE TOP 18MM THICK GRANITE TOP 18MM THICK GRANITE TOP
SIDE ELEVATION
Tables in the entrance area for pasting of soiled
notes : To be made using 19mm thick BWR
grade plywood (conforming to IS-303 of 1989)
for the leg structure and top and fixing of 18mm
thick polished granite on the table top. The table
shall be of size 3'x2'. The item has to be
completed in all respects including cost &
conveyance of all materials, labour charges etc
complete as directed by the Architect / Banks
Engineer .
1TEM NO.20 OF B.O.Q
Wall panelling : To be with a frame work of
Boral make 51mm x 35mm metal studs at 2'-0"
c/c and 51mm x 32mm metal tracks at 2'-0" c/c
with joints staggered to avoid through joints,
fixed with 8mm thick BWR grade ply fixed on
the external side only and pasted with 1.5mm
thick laminate of approved shade and design in
combination of three colors as per design..
ELEVATION OF SWITCH ROOM PARTITION
BUILDING CRAFTS,
DWG NO : BC/RBI/HYD/INT/TENDER/WALL PANELLING/112-2005.
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,# 3-5-170/A/6/1, First Floor
PH: 040 - 23 22 3049, 98490 16869.
Narayanguda,Hyderabad -500 029.
DESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
COPIED, TRACED, REPRODUCED, MODIFIED
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENTLENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
DECISSION OF THE ARCHITECTS REGARDING THEDESIGN DETAILS SHALL BE FINAL.
M/S BUILDING CRAFTS, AND SHALL NOT BE
BEFORE QUOTING FOR THE TENDERS
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
CHECKED BY : SANJAY
DRAWN BY : RAJASEKHAR
SHEET TITLE :
DATE : 12th APRIL '2005
INTERIORS OF BANKING HALL OF
PLEASE DONOT SCALE THE DRAWING,
HYDERABAD.
PROJECT -
consultants -
NOTE :
THE PROBABLE CONTRACTORS SHALL SATISFY
THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
NOTE:
S.No. AS PER BOQDETAIL DRAWINGS OF
1TEM NO.30
WALL PANELLING 1TEM NO.31
TABLE FOR PASTING
SOILED NOTES1TEM NO.20
ELEVATION OF WALL PANELLING
8'-6"
2'-6"
4MM RECESSED GROOVE AT EVERY 1'-6" INTERVAL
11'
7'
Panelling for the Full height partitions for the switch rooms : Existing partitions shall be
fixed with 6mm thick BWR Grade plywood (conforming to IS-303 of 1989) on either sides and pasted with 1.5mm thick laminate of approved shade and design in a
combination of three colors as per design.
PLANTER BOXES: Size 1'3" x 1'6" x 1'3":To be
made using 18mm thickWWR Grade-2 MDF board
(conforming to IS-12406 of 2003) with all external
surfaces fixed with laminate of 1.5mm thick and all
internal surfaces fixed with 0.8mm thick GI sheet
PLANTER BOX
4MM RECESSED GROOVE AT
EVERY 1'-6" INTERVAL
6MM PLYWOOD WITH
1.5 MM LAMINATE
1TEM NO.35 OF B.O.Q
1TEM NO.30 OF B.O.Q
PLANTER BOX 1TEM NO.35
19MM THICK PLY WITH 1.5 MM LAMINATE
DARKER SHADE MARBLE INLAY IN EXISTING COLUMN
ELEVATION OF COLUMN INLAY WORK
10'-6"
INLAY WORK IN
EXISTING COLUMN
1TEM NO.31 OF B.O.Q
2'
1TEM NO.37 OF B.O.Q
PANELLING FOR THE FULL HEIGHT
PARTITIONS FOR THE SWITCH ROOM 1TEM NO.37
EXISTING MARBLE CLADING
SOFT BOARD
BOX TYPE PANELLING2'
4'-6"
to Banking Hall
Public Entrance
up
Toilets
up
Existing Server
Room
EXISTING PAD & DAD WORKSTATIONS
Server
Window
EXISTING
Record Room
up
Security Officer
DAY TO DAY VAULT
8'
(Access for Heavy Cash)
Entrance
Rear Side
waiting
EXISTING Receptionup
FOR D.A.D.BOOK ROOM EXISTING
Access for Heavy Cash
EXISTING
DAY TO DAY VAULT
BOOK ROOMEXISTING
8'-1"
Security
3'
18'-212"
3'
312"
10'-8"3"
2'
2'
6'-012"
3"
6'-012"
3"
6'-212"
3"
6'-212"
3"4'-3"
4'-3"
5'-6"
6'-3" 2'
2'-9" 2'
6'-3" 2'
6'-3" 2'
4'-512"
4'-8"
3"
5'-3"
3"
5'-3"
3"
4'-3"
4'-3" 2'
2'
2'-1112"
6'-3"
2'
2'-9"
2'
6'-3"
2'
8'-6"
2'-3"3"
7'-712"
3"
10'
10'
16'
9'-6"
3'-6"
4'-8"
4'
4'-5"
6'
8'
10'
3"
3'
3'
9"
3'
12'-9"
16'-7"
7'-3"
4'
10'
8'-3"8'-3"
15'-6"
7'-2"
8'
10'
10'
6'-1"
2'-9"
3"
2'-9"
6'-112"
3"2'-112"
10'-3"
10'-3"
7'-9"
5'-3"4'-1"
1'-212"
2'
10'-3"
15'-5"
6'
4'-912"
6'-512"3'
5'
5' 16'-9"8'-3" 12'-6"
4'
3"
4'
3"
4'
3"
4'
3"
5'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'
3"
4'3"
4'
3"
5'-3"
5'-10"
4'-9"
5'-1"
4'-4"
4'-4"
4'-8"
4'-8"
5'-5"
5'-512"
18'
10'-3" 6'-6"
15'-712"
18'-10"
8'-4"
5'-9"
17'-012"
26'-8"
12'-9"
15'-2"
7'-1"
8'-9"
9'-9"
11'-6"
3"
3"
2'-9"
4'-3"
3"
4'-4"
3"
4'-4"
3"
4'-4"
3"
4'-1012"
3"
4'-1012"
3"
4'
RESERVE BANK OF INDIA,
consultants -
HYDERABAD.
Hyderabad -500 029.
Narayanguda,
PH: 040 - 23 22 3049, 98490 16869.
# 3-5-170/A/6/1, First FloorLane Adj. Venkateshwara Motors,
architects, engineers & interior designersBUILDING CRAFTS,
NOTE :
PROJECT -
PLEASE DONOT SCALE THE DRAWING,
INTERIORS OF BANKING HALL OF
DATE : 8th OCTOBER '2005
DRAWN BY : SRINIVAS
CHECKED BY : SANJAY
FOLLOW ONLY WRITTEN DIMENSIONS
3'X3' VETRIFED TILED FLOORING WITH
DARK COLOUR VETRIFIED TILE INLAY
1TEM NO.26, 27,28 & 29 OF B.O.Q
GREEN KOTAH STONE WITH LIGHT
COLOR MARBLE TILE INLAY
DWG NO : BC/RBI/HYD/INT/TENDER/FLOORING/113-2005.
S.No. AS PER BOQDETAIL DRAWINGS OF
FLOORING LAYOUT1TEM NO.26,27,
28,29
9"
9"
ENTRANCE
waiting area
8'
2'-2"
2'-2"
water body
reception
DECISSION OF THE ARCHITECTS REGARDING THE
architects, engineers & interior designers
Lane Adj. Venkateshwara Motors,
PH: 040 - 23 22 3049, 98490 16869.
DESIGN DETAILS SHALL BE FINAL.
CHECKED BY : SANJAY
INTERIORS OF BANKING HALL OF
BUILDING CRAFTS,
FOLLOW ONLY WRITTEN DIMENSIONS
RESERVE BANK OF INDIA,
PLEASE DONOT SCALE THE DRAWING,
DWG NO : BC/RBI/HYD/INT/TENDER/FALSE CEILING/114-2005.
Narayanguda,
Hyderabad -500 029.
HYDERABAD.
PROJECT -
consultants -
NOTE :
# 3-5-170/A/6/1, First Floor
DRAWN BY : RAJSHEKHAR
DATE : 14th APRIL '2006
BEFORE QUOTING FOR THE TENDERSDESIGN DETAILS AND SITE COMPATIBILITY
THIS DRAWING AND DESIGN IS THE SOLE PROPERTY OF
COPIED, TRACED, REPRODUCED, MODIFIED
LENT, OR MADE UNAUTHORISED USE OF IN ANY OTHER
M/S BUILDING CRAFTS, AND SHALL NOT BE
THE PROBABLE CONTRACTORS SHALL SATISFY THIS DRAWING IS FOR TENDER PURPOSE ONLY,
THEMSELVES WITH THE SITE CONDITIONS AND THE
ANY DISCREPENCY IN THE DRAWING SHALL BE
OF THE ARCHITECTS M/s BUILDING CRAFTS.
BROUGHT TO THE NOTICE OF THE ARCHITECTS.
MANNER WITHOUT THE WRITTEN PRIOR CONSENT
NOTE:
SHEET TITLE :
S.No. AS PER BOQDETAIL DRAWINGS OF
FALSE CEILING LAYOUT 1TEM NO.23
1TEM NO.23 OF B.O.Q
to Banking Hall
Public Entrance
up
Toilets
up
Existing ServerRoom
switch room
EXISTING
Record Room
up
DAY TO DAY VAULT
8'
(Access for Heavy Cash)
Entrance
Rear Side
waiting
EXISTING Receptionup
FOR D.A.D.BOOK ROOM EXISTING
Access for Heavy Cash
EXISTING
DAY TO DAY VAULT
BOOK ROOMEXISTING
to Banking Hall
Public Entrance
up
Existing ServerRoom
switch room
EXISTINGDAY TO DAY VAULT
(Access for Heavy Cash)
Entrance
Rear Side
waiting
EXISTING Receptionup
FOR D.A.D.BOOK ROOM EXISTING
Access for Heavy Cash
EXISTING
DAY TO DAY VAULT
+ 8'6"
+ 8'6"
+ 8'6"
+ 8'6"
+ 8'6" + 8'6"+ 8'6"
+ 8'6" + 8'6" + 8'6" + 8'6"
+ 8'6"+ 8'6"
+ 8'6"
+ 8'6"
+ 8'6"+ 8'6"
+ 8'6"
+10'-6" +10'-6"
+10'-6"
+11'-0"
+11'-0"
+ 8'6"
+ 8'6"
+ 8'6"
+ 8'6"
+ 8'6"
+10'-6" +10'-6" +10'-6" +10'-6" +10'-6" +10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
+10'-6"
ENTRANCE
2'-2"
2'-2"
M
M
O
H
H
Z
Z
Z
LEGENDSYMBOL
DESCRIPTION
PUBLIC ADRESS SYSTEM
ADDRESSABLE OPTICAL
SMOKE DETECTOR
ADDRESSABLE OPTICAL SMOKE
DETECTORWITH FAULT ISOLATOR BASE.
M ADDRESSABLE MANUAL CALL POINT
BEAM DETECTOR TRANSMITTER
ADDRESSABLE OUTPUT MODULE.
H ADDRESSABLE LOOP SOUNDER/HOOTER
Z ADDRESSABLE ZONE MONITORING MODULE
RESPONSE INDICATOR
STRODE LIGHT
BEAM DETECTOR RECEIVER
O