red yellow charcoal grey · drawing shrub species 4 generic specifications item grass ·kikuyu...
Post on 19-Jun-2020
1 Views
Preview:
TRANSCRIPT
DRAWINGITEMB
IN
PA
VIN
G
PEDESTRAIN WALKWAY:
Corobrik Burgundy Paver PA, clay paving
brick, size: 220 x 110 x 50 mm thick
Colour type: RED
PEDESTRIAN WALKWAY:
Corobrik Cederberg Paver PA, clay paving
brick, size: 220 x 110 x 50 mm thick
Colour type: YELLOW
220
11
0
GENERIC
SPECIFICATIONS
DRAWING
· Fixed perforated bin litter
· 2 legs (filled with concrete) as per
detail drawings
· Bin diameter: 400mm
· Bin depth: 560mm
· Leg diameter: 50mm
· Height: 760mm
· Finish for legs and bin:
Galvanized Steel
NB: ALL LEGS TO FILLED IN WITH
CONCRETE
1
220
11
0
2
Concrete footing
to Eng. detail
Paving finish level or
Top of grass lawn
dressing
Perforated galvanised
steel bin
BE
NC
H
400
56
0
76
0
· Precast Concrete Bench
· 1600 mm in length
· 450 mm in height
· 450 mm in width
· Smooth natural grey concrete
Finish: Special smooth & fair finish:
Special (Smooth & Fair): Grade I
accuracy; the standard of finish shall
be such that upon removal of the
formwork,no further treatment, other
than treatment of bolt holes if
required, shall be found necessary to
provide a straight, smooth and
uniform finish of good quality and
consistent colour and texture, free of
all honeycombing etc.
NB: LEGS TO BE CAST INTO
CONCRETE FOOTING
1600
45
0
Paving Finish level or
Top of grass lawn
dressing
Concrete footing
to Eng. detail
Precast concrete
bench with 10 mm
chamfer all corners and
edges and to be cast
into conc footing
PEDESTRIAN WALKWAY:
Standard concrete cobble 110 x 110 x 50 mm
Colour type: Charcoal
110
11
0
GENERIC
SPECIFICATIONS
ITEM
50 mm thick
50 mm thick
CB
CC
CCC
PE
DE
ST
RIA
N L
IG
HT
Post top luminaire:
BEKA ZELA
50
00
Steel Pole, Stepped 5
metres mounting height.
Finish: Powder coated
black
Top of pavers
Post:
Steel Stepped Pole
Finish: Powder coated black
Light:
Beka Zela
Finish: Standard colour grey
· ALL OTHER SPECIFICATIONS BY
ELECTRICAL ENGINEER
VANSTONE JAP SLAB along
existing retaining wall along ST JOHNS RD
and atop retaining walls
Size: 600 x 300 x 60 mm
Colour Type: Grey
30
0
600
50 mm thick
PEDESTRIAN WALKWAY
along St Johns Rd:
Concrete interlocking paving blocks to match
existing pavers
size:110,8 x 221,2mm x 60mm
Colour type: Grey
60 mm thick
221.2
11
0.8
G-50
BUS LAY BYE
Infraset: CRAZE G-Bloks concrete
interlockers, size: 221.2x110,8x 80mm
Colour type: MULTI-BLEND
220
11
0
MB-80
80 mm thick
CONCRETE EDGE BEAM
cast-in-situ along existing stone retaining wall.
Apply 19mm aggregate gravel (Worcester or
similar) on top of concrete and set into concrete
to cure.
Size: 300 deep x 800 mm width
Colour Type: Grey with 19mm aggregate gravel
HBRP 2211
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
e office@jhb.gapp.net
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REV.
CLIENTARCHITECT
JN
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
e office@ctn.gapp.nett
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect C 300
Furniture Template
1
not to scale2019.06.19
B
A JN Issue for information07 May 2019
Heritage Landscape and Public
Environment Upgrade
B JN Tender Issue19 June 2019
BU
S S
HE
LT
ER
S
TE
EL
R
OO
F S
TR
UC
TU
RE
GENERIC
SPECIFICATIONS
DRAWING
3
ITEM
Top of pavers
203 x 203 m/steel H- column to be
used as roof support / gutter.
152 x 152 M/steel H-column welded to
base plate and bolted to r.c footing
IPE 200 rafter cut to shape
75 x 50 x 20 C channel purlin and
spacing
ROOF SHEETING:
Corrugated chromadek roof sheeting
@ 5°ROOF SLOPE. Colour finish:
Dark Dolphin and Pebble Grey to
underside.
26
00
900 1600
All steel works to be painted and colour:
RAL 7011 (IRON GREY)
PU
BL
IC
P
AR
K F
EN
CE
100 x 8 mm thk Galv. steel flat frame
vertical post to be cast into conc
footing
6 mm thick x 60 mm Galv. steel flat
frame surround
20 dia galvanised steel tube verticals
to be set each at 100 mm c/c.
REPRESENTATIONAL PICTURE ONLY
12
00
2000
100
100
Ground Level
REPRESENTATIONAL PICTURE ONLY
Concrete footing
to Eng. detail
PUBLIC PARK FENCE - SECTION 2
AND 3 OF WORKS
20
09
00
DRAWING
SH
RU
B S
PE
CIE
S
4
GENERIC
SPECIFICATIONS
ITEM
GR
AS
S
· Kikuyu instant lawn
· Lawn Dressing at a rate of 1m3 per 30 m² of
instant lawn.
LAWN: KIKUYU GRASS
· Topsoil
· Compost
· Mulch
· Superphosphate
· Fertilzer
· Vermiculite
Soil improvement
specifications:
Aloe marlothii
Mountain aloe - 100 lt bag
Bigger side panel: 330 x 1670 x 15 mm
thk min clear perspex fixed with flat
steel patch fittings.
Small side panel: 1670 x 200
Steel sheet fixed with flat steel
patch fittings. Thickness to be a
min of 16 mm.
· ALL SPECIFICATIONS TO BE
CONFIRMED BY STRUCTURAL
ENGINEER
8 mm thick shaped m/steel seat side supports,
bolted to steel columns to Engineer's specs
and details
GR
OU
ND
C
OV
ER
S
PE
CIE
S F
OR
P
LA
NT
ER
DIETES BICOLOR: YELLOW WILD IRIS (2 lt)
to be planted at a rate of 5 plants per m²
· Import and spread topsoil @ 500mm deep
· Import and spread compost. Application
rate: 150mm / m²
· Fertilizer (2:3:2). Application rate: 0.05Kg /
m²
· Superphosphate: Application rate: 0.1Kg/m²
· Vermiculite: Application rate: Vermiculite to
be applied at 15% / m3 of topsoil
· Watering IMMEDIATELY after planting at a
rate of approx. 2 litres of water / m²
DIETES GRANDIFLORA: FAIRY IRIS (2 lt) to
be planted at a rate of 5 plants per m²
DIETES BICOLOR: YELLOW WILD IRIS
DIETES GRANDIFLORA: FAIRY IRIS
WA
LL
150MM DEEP RANDOM SIZED SLATE
CLADDING AND COPING DRY-PACKED
BETWEEN 120X120X6MM MS ANGLE
FIXED BACK TO RC WALL @ 1M
VERTICAL C/C.
MIN STONE THICKNESS 30MM
MAX. STONE THICKNESS 60MM
RC slab
Dry stacked stone
cladding
Type of stone:
Slate
Brickwall
150
· Type of tree: Fever Tree
(ACACIA
XANTHOPHLOEA) 100
litre tree. Stem diameter 50 mm,
height 2 metres minimum FROM TOP OF
ROOT BALL and
· Tree positions as per street layout
· Stakes to be installed prior to tree being
planted and pole filled
CARPOBROTUS EDULIS: HOTTENTOTS-FIG
CARPOBROTUS EDULIS: HOTTENTOTS-FIG
(2 lt) to be planted at a rate of 5 plants per m²
G A P Parchitects/urban designers
johannesburg97 second avenue
melville 2092t +27 11 482 1648f +27 11 482 1216
e office@jhb.gapp.net
PROJECT DRAWING TITLE
DATE
JOB NO
AUTHOR
DRAWING NO.
SCALE
REV.
CLIENTARCHITECT
JN not to scale
No. DATE By DESCRIPTION
Johannesburg Development
Agency
cape town150 longmarket street
cape town 8001t +27 21 424 2390f +27 21 426 1324
e office@ctn.gapp.nett
General Notes:
1) All pedestrian ramps to be installed parallel to property boundaries.
2) Levels from sidewalks across driveways to be flush for disabled access.
3) All road markings to be repainted.
4) All existing traffic signs and light poles to be repaired, painted or replaced
where necessary.
5) Final Positions of kerb inlets and pedestrian
ramps to be verified on site.
If the contractor discovers conflicts between
the architectural drawings and the engineers'
drawings, he is to contact the architect C 301
Furniture Template
2
B
A JN Issue for information07 May 2019
Heritage Landscape and Public
Environment Upgrade
HBRP 2211
B JN Tender Issue19 June 20192019.06.19