Realizing a Class 1 Ultrasonic Gas Meeter
without HP Calibration - an innovative
approaches contributing to an economic
upstream metering solution
Thomas Horst - Sick
REALIZING A CLASS 1 ULTRASONIC GAS FLOW METER WITHOUT HP CALIBRATION
Author: Thomas Horst - SICK AG
Co-Author: S. Stoof, A. Prade – SICK AG
European Flow Measurement Workshop 2015
2SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
GAS PRODUCTION APPLICATIONS
Challenging conditions in gas production:▸ Varying flow rates
▸ Varying gas quality
▸ Saturated gas streams with entrained liquids
Demand for meters that are:▸ Robust for use in production environments
▸ Economic in a long-term perspective
In fact: Meters for gas production applications are mainly covered by dP meters.
UPSTREAM MEETS ULTRASONICS
USM provide several advantages over dP meters:
( + ) Higher turn-down ratio( + ) Reduced pressure drop( + ) Virtually no maintenance( + ) Valuable diagnostics data
What about Ultrasonic meters in gas production?
USM are equally applicable:
• Highly robust, even for high LVF – no wear• Self-draining, self-recovering
3SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
COMPLETING THE VALUE CHAINUPSTREAM METERING WITH USM’S
Upstream Midstream Downstream
Production Gathering Transmission Storage Distribution Residential
4SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
Gathering SystemIf same owners, just 1 meter If different may be 1 owned by gatherer and sometimes a check meter on the pad
Multi Well Gas w / production and test separators• 2 to many wells• Each wells are cycled through a test separator, either
automatically or manually• On site facilities can be small to very large
Tanks or pipeline
Test Separator
ProductionSeparator
PRODUCTION CONFIGURATIONS
5SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
LARGE TURN-DOWN
FLOWSIC600 DRU covers typical range of 2..6 inch orifice plate meters.
6SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
� Dual path meter design
� Precise meter body manufacturing with tight tolerance limits
� Tailor-made US sensors and path layout
� Integrated 10D upstream piping
� Individual LP calibration
LOW UNCERTAINTY (CLASS 1 METER) WITHOUT INDIVIDUAL HIGH PRESSURE CALIBRATION
Meter body manufacturing precision
Superior transducer technology
Zero flow test and verification
In-house ambient air flow calibration
Quality assurance for HP natural gas
Steps to uncertainty: ±1%
� No individual HP calibration
� Significantly reducedsystem price.
7SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
EVALUATION ON A PRODUCTION LOT OF 25 METERSMANUFACTURING PRECISION
59,95
59,96
59,97
59,98
59,99
60
60,01
60,02
60,03
60,04
60,05
14
39
00
40
14
39
00
42
14
39
00
44
14
39
00
46
14
39
00
48
14
39
00
50
14
39
00
52
14
39
00
54
14
39
00
56
14
39
00
58
14
40
00
47
14
40
00
49
14
40
00
51
14
42
00
61
14
42
00
63
14
42
00
65
14
42
00
67
14
42
00
69
14
42
00
71
14
42
00
73
14
42
00
75
14
42
00
77
14
42
00
79
14
42
00
81
14
42
00
83
Pat
h an
gle
[deg
]
Path angle
Path 1 Path 2
Tolerance limit ±0.02 deg
134,8
134,85
134,9
134,95
135
135,05
135,1
135,15
14
39
00
40
14
39
00
42
14
39
00
44
14
39
00
46
14
39
00
48
14
39
00
50
14
39
00
52
14
39
00
54
14
39
00
56
14
39
00
58
14
40
00
47
14
40
00
49
14
40
00
51
14
42
00
61
14
42
00
63
14
42
00
65
14
42
00
67
14
42
00
69
14
42
00
71
14
42
00
73
14
42
00
75
14
42
00
77
14
42
00
79
14
42
00
81
14
42
00
83
Pat
h le
ngth
[mm
]
Path length
Path 1 Path 2
Tolerance limit ±0.1 mm
0
0,05
0,1
0,15
0,2
0,25
0,3
14
39
00
40
14
39
00
42
14
39
00
44
14
39
00
46
14
39
00
48
14
39
00
50
14
39
00
52
14
39
00
54
14
39
00
56
14
39
00
58
14
40
00
47
14
40
00
49
14
40
00
51
14
42
00
61
14
42
00
63
14
42
00
65
14
42
00
67
14
42
00
69
14
42
00
71
14
42
00
73
14
42
00
75
14
42
00
77
14
42
00
79
14
42
00
81
14
42
00
83Par
alle
ilism
[mm
]
Path Paralleilism
Tolerance limit <0.3 mm
21,9
22
22,1
22,2
22,3
22,4
14
39
00
40
14
39
00
42
14
39
00
44
14
39
00
46
14
39
00
48
14
39
00
50
14
39
00
52
14
39
00
54
14
39
00
56
14
39
00
58
14
40
00
47
14
40
00
49
14
40
00
51
14
42
00
61
14
42
00
63
14
42
00
65
14
42
00
67
14
42
00
69
14
42
00
71
14
42
00
73
14
42
00
75
14
42
00
77
14
42
00
79
14
42
00
81
14
42
00
83
Pat
h po
sitio
n [m
m]
Path position
Path 1 Path 2
Tolerance limit ±0.15 mm
8SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
AMBIENT AIR CALIBRATION RESULTS
-2,5
-2,0
-1,5
-1,0
-0,5
0,0
0,5
1,0
1,5
2,0
2,5
0 100 200 300 400 500 600 700
Err
or [%
]
Flow rate [m³/h]
Ambient air calibration – as left
RESULTS ON A PRODUCTION LOT OF 25 METERS
9SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
VERIFICATION OF OUT-OF-THE-BOX PERFORMANCE RESULTS ON HIGH PRESSURE TEST FACILITY
-2,5
-2,0
-1,5
-1,0
-0,5
0,0
0,5
1,0
1,5
2,0
2,5
0 100 200 300 400 500 600 700
Err
or [%
]
Flow rate [m³/h]
High pressure flow test – as found
4bar 50 bar Ambient Air 2bar
10SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
FLOW DISTURBANCE TEST RESULTS
-1,00
-0,75
-0,50
-0,25
0,00
0,25
0,50
0,75
1,00
6904802756934,5
Dev
iatio
n to
Bas
elin
e [%
]
Flow rate [m³/h]
Flow disturbance test of FLOWSIC600 DRUFC: CPA 55E, Distance: 10D, OIML R137 (mild) / ISO 17089
7094_S16 zurueck_CPA55E_10D_SEL 7099_S16 zurueck_CPA55E_10D_SER7100_S16 zurueck_CPA55E_10D_DER 7103_S16 zurueck_CPA55E_10D_DEL7104_S16 zurueck_MUT90Gr_CPA55E_10D_DEI 7108_S16 zurueck_CPA55E_10D_GV7110_S16 zurueck_CPA55E_10D_STP 7111_S16 zurueck_CPA55E_10D_CO7112_S16 zurueck_CPA55E_10D_DI
11SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
� Test at CEESI Nunn
� 13 barg and 55 barg
� 95..100% GVF
WET GAS TESTING
12SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
Comparison: dual chamber orifice with one beta (0,517) – Natural gas / WaterWET GAS TEST RESULTS
: Continuous operation for alltested LVF
: Acceptable allocation accuracy up to 0.5 % LVF
� USM is robust even in wet gas conditions
FLOWSIC600 DRUOrifice Meter Error Difference Relative to Dry GasPressure = 800 psia - With CPA
-5,0
0,0
5,0
10,0
15,0
20,0
25,0
30,0
35,0
40,0
45,0
0 10 20 30 40 50
Ref Gas Velocity (ft/s)
Error
GVF = 99.88
GVF = 99.76
GVF = 99.52
GVF = 98.83
GVF = 97.70
GVF = 95.44
2 Path Meter Error Difference Relative to Dry GasPressure = 800 psia - With CPA
-5,0
0,0
5,0
10,0
15,0
20,0
25,0
30,0
35,0
40,0
45,0
0 10 20 30 40 50
Ref Gas Velocity (ft/s)
Error
GVF = 99.88
GVF = 99.76
GVF = 99.52
GVF = 98.83
GVF = 97.70
GVF = 95.44
13SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
INNOVATIVE LIQUID DETECTION DIAGNOSTICS
� Fully automated monitoring of all diagnostic parameters
� Algorithm using diagnostics to generate a warning when liquids are present that may have an impact on process quality or measurement accuracy
� Operation expenditures stay low due to intelligent diagnostics telling you when maintenance and inspections are really necessary
14SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
� High rangeability
� Virtually maintenance-free
� Identification of time periods with potential measurement issues by inbuilt liquid detection
� Indication of measurement data quality
� Potential for production optimization to avoid liquid production
FLOWSIC600 DRU – CUSTOMER BENEFITS
15SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
� Measurement effects of wet gas on ultrasonic meters are significant and not trivial to overcome
� FLOWSIC600 DRU is not a wet gas meter , but is robust for wet gas production applications and provides substantial added value by
▸ Large turn-down
▸ Low OpEx
▸ Long-term stability
▸ Liquid detection diagnostic
� Further research must be done on liquid correction of USM
� Tests and projects are ongoing – results will be published subsequently
SUMMARY
16SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
What are main concerns for US metering in gas produ ction?
� Economic in CapEx and long-term perspective?
� Robust for production applications?
� Low measurement uncertainty?
� Diagnostic values with added value in upstream applications?
UPSTREAM MEETS ULTRASONICS
17SICK Flow Solutions | European Flow Measurement Workshop 2015March 2015
Thomas Horst
SICK Flow Solutions
Thomas.Horst@sick.de
MANY THANKS FOR YOUR ATTENTION.