quick reference card · 2019. 3. 5. · quick reference card please consult your spa user manual...
Post on 28-Aug-2020
0 Views
Preview:
TRANSCRIPT
Description
Main functions
Quick Reference CardPleaseconsultyourspausermanualforcompleteinfoonthefeaturesofyourspasystem.
in.k600™Advanced series of full-function keypads that give complete control to wet fingers!
Aeware's®newseriesofkeypadsfeaturesahighprofilewithalargeLCDdisplay,menu-driveninterfacethatletuserseasilycontrolallin.xm™functionsandprogrammingdirectlyfromspaside,creatingatrueanduniqueuserexperience.
Pumpicons
Lockicon
Time,temperature&messages
Progressbaricon
MenutitleOperationMode
Informationdisplay
Statusicons
Lighticon
OKKey
NextKeygoestomenupage
ModeKeyselectsmodeofoperation:Spa,Audio,Options
RightMulti-functionKey
-Keydecreasespar-ametersetting
LeftMultifunctionKeygoesbackto
previousparametersettingorincreases
parametervalue
SoftKey1,2,3,4
+Keyincreasesparametersetting
Serviceicon
AM/PM(˚F/˚C)
• SelectSpatoviewSpamenu.
Starting Pump 1
• SelectPump 1toturnPump1on.•SelectPump 1repeatedly
tocontrolpump1speed.
(20minutebuilt-intimer)
Starting all accessories*
•PresstheQuick On/Offbuttontostartallaccessories(pumpsandturbines)inhighspeed.
•PresstheQuick On/Offbuttonagaintostopallaccessories(pumpsandturbines).Thereisanintegrated120minutetimer.
Light
•SelectLightkeytoturnlighton.•SelectLightkeyrepeatedlyto
controllightintensity.Afinalselectionturnslightoff.
(120minutebuilt-intimer)
Next menu page
•PressNext keytodisplaythenextpageinthespamenu.
Goestobloweroption
Thismenuallowscontrolofallpumps,blower,andspalight,aswellastheactivationoftheEconomyandStandbymodes.Animatediconsaredisplayedwhendevicesareon.AllpumpactivitycanbestoppedatoncebyactivatingtheStandbymode.
Starting Pump 2*
• SelectPump 2toturnPump2on.•SelectPump 2repeatedly
tocontrolpump2speed.
(20minutebuilt-intimer)
• PressModekeytodisplaythemodeSelectionwindow.
Starting Pump 3*
• SelectPump 3toturnPump3on.•SelectPump 3oncemore
toturnpump3off.
(20minutebuilt-intimer)
Water temperature settings
• PressPlus/Minuskeystoselectwatertemperaturesetting.
• PressOKorwait5secondstoconfirmnewsetting.The“SetPoint”promptindicatesthedesiredtemperatureNOTthecurrentwatertemperature.
*optionavailabledependinguponfactorysettings
Economy Mode
Lowersthetemperaturesetpointofthespaby20˚F(11˚C).
•SelectEconomy toactivatetheEconomymode.
•SelectEconomy againtoover-rideeconomyprogramming(seespasetupsection).
Standby Mode
Stopsallpumpsatthesametimebyasimpleclickofabutton!
•PressStandbytoactivate thismode.•PressStandbyagaintoresume
normaloperations.
SystemautomaticallyreturnstoNormalmodeafteracertainperiodoftime,unlesstheStandbymodehasbeenreactivated.SpalightwillflashforafewsecondsbeforetheexitofStandbymodeandrestartthepumps.The"Standby"messageisalsodisplayedduringStandbymode.
*Pumpwillstayturnedonifthere isarequestformoreheat.
Displaying time
• PressOKkeytodisplaythetime.•PressOKkeyasecondtimeto
gobacktowatertemperaturedisplay.
Viewing active progress bars
Aprogressbarisavisualindicatorofthetimeremainingbeforeadeviceisturnedoff.Onlyonebarisdisplayedatthetime.
•UseLeftorRightkeystovisualizetheprogressbarofeachactivateddevice.
Starting Blower*
•PressBlowertoturnBloweron.•PressBlower oncemoretoturn
bloweroff.
(20minutebuilt-intimer)
Programming
Setting filter cycle start time
Thedisplaywillshowthestartinghourpreviouslyset.
•Use(+)or(-)keytoselecthoursetting.
•UseRightkeytosetminutes.•Use(+)or(-)keytochange
minutes.•SelectNextarrowon
screenmenutogotothenextparameter:filtercycleduration.
Setting cycle duration
Herewesetavalueforthefiltercycleduration,inhoursandminutes.
•Use(+)or(-)keytosethour.•UseRightkeytosetminutes.•Use(+)or(-)keytochange
minutes.•SelectNextarrowonscreen
menutosavechangesandgotothenextparameter:filtercyclefrequency.
Setting filter cycle frequency
Herewesetthenumberoffilteringcyclesthatthesystemwillperfomperday.
•Use(+)or(-)keytoselectfrequencysetting.
•SelectEntertosavechangesandgobacktospaoptionsmainmenu.
Setting Economy mode*
•SelectEconomy
Programming the spa system
Toprogramthefiltercycle,youmustentertheseparameters:starttime,durationandfrequency.Duringafiltercycle,pumpsrunforoneminutetopurgetheplum-bing,thenPump1runsfortheprogrammednumberofhours.
•PressModekey•SelectOptionsmenu•SelectSpasub-menu•SelectFilteroption
Setting Economy start time
•SelectNextarrowtosavechangesandgotoeconomycyclestarthour.
•Use(+)or(-)keytosethoursetting.
•UseLeftkeytoaccessminutesoption.
•Use(+)or(-)keytosetminutes.•SelectNextarrowtosave
changesandgotothenextparameterstopeconomy.
Setting Economy stop time
•Use(+)or(-)keytosethour.•UseLeftkeytoaccessminutes
option.•Use(+)or(-)keytosetminutes.•SelectEnteroptiontosave
changesandgobacktospaoptionsmenu.
Setting maintenance reminder prompts
Thismenuallowsyoutoactivate/deactivateorsimplyresetthemaintenancereminderprompts.
•SelectReminder option
Turning reminders on/off*
•Use(+)or(-)keytoactivateordeactivateprompt(s).
•SelectNextarrowtosavechangesandgotonextmenuscreen.
Setting Economy status
•Use(+)keytoenabletheeconomymode,thedisplaywillshowOn.
•Use(-)keytodisableeconomymode,thedisplaywillshowOff.
*optionavailabledependinguponfactorysettings
Viewing spa warnings
Thewarningiconshowsuptopromptyoutoreviewactivewarningmessages.
Resetting prompt messages
•UseLeftorRightkeystoreviewonebyoneallactivemaintenancemessages.
•SelectEntertoresetmessageandviewnexttaskorgobacktomainmenu.
Spa warnings
Thismenuallowsyoutoviewallactivewarningmessagesi.e.hotwater.
•SelectWarningoption
Turning warnings on/off
•UseLeftorRightkeystoreviewallwarningmessages.
•PressModekeyagaintogobacktomainmenu.
Viewing spa reminders
Theremindericonwillshowupwhenyouhaveactivemaintenancemessages.
Setting the time
•PressModekey•SelectOptionsmenu•SelectClocksetting
Setting hour settings
•Use(+)or(-)keytosethour.•UseLeftorRightkeytoaccess
minutesoption.•Use(+)or(-)keytosetminutes.•SelectEntertogoback
tothekeypadmainmenu.
Setting keypad display options
Thissub-menuisusedtosetkeypaddisplaysettingssuchascontrast,backlight,etc.
•SelectDisplayoptions
Adjusting contrast
•UseLeftorRightkeystoadjustdesiredlevelofcontrast.
•SelectNextarrowondisplaytosavechangesandgotonextscreenmenu.
Adjusting backlight
•UseLeftorRightkeystoadjustbacklightbrightness.
•SelectNextarrowondisplaytosavechangesandgotonextscreenmenu.
Normal/Reverse display
•Use(+)or(-)keytoactivateordeactivatereversedisplay.
•SelectNextarrowondisplaytosavechangesandgotonextscreenmenu.
To program keypad settings
•PressModekey•SelectOptionsmenu•SelectKeypadsub-menu
Display orientation (inverting)
•Use(+)or(-)keytoactivateordeactivateinverteddisplay.
•SelectEnteroptiononscreenmenutobacktokeypadmainmenu.
Setting keypad audio options
Thissub-menuisusedtosetkeypadaudiooptionssuchas:keypadon(keybeep)andalarm.
•SelectSoundoptions
Keypad beep on/off
•Use(+)or(-)keytoactivateordeactivatethekeypadbeep.
•SelectNextarrowondisplaytosavechangesandgotonextscreenmenu.
Setting regional settings
Thissub-menuisusedtosetkeypadregionalsettingssuchaslanguage,temperaturedisplayunitsandformatfortimedisplay.
•SelectRegionaloptions
Alarm sound
•Use(+)or(-)keytoactivateordeactivatealarmsound.
•SelectEntertosavechangesandgobacktomainmenu.
Time setting
Other settings
Resetting keypad programmed values
•PressOKtoresetbacktodefaultfactoryvalues.
•SelectNextarrowondisplaytonextscreenmenu.
Viewing information about spa
SpasoftwareIDnumberandversionaredisplayed.
•SelectNextarrowondisplaytonextscreenmenu.
Viewing information on heater software
HeatersoftwareIDnumberandversionaredisplayed.
•SelectNextarrowondisplaytonextscreenmenu.
Viewing information on keypad software
KeypadsoftwareIDnumberandversionaredisplayed.
•SelectNextarrowondisplaytonextscreenmenu.
Upgrading keypad software
•UseOKkeytostarttheupgradeofthekeypadsoftware
•SelectEntertogobacktothekeypadmainmenuandcancelsoftwareupgrade.
Viewing information about the system
Toviewspaequipmentdataandkeypadsoftwareversion,andtoresetprogrammedsettingsandtoupgradekeypadsoftware.
•PressModekey•SelectOptionsmenu•SelectInfosub-menu
Language
•Use(+)or(-)toselectfrom:English,Français,Español&Deutsch
•SelectNextarrowondisplaytosavechangesandgotonextscreenmenu.
Temperature units
Watertemperaturecanbedisplayedin°For°C.
•Use(+)or(-)tochangesetting.•SelectNextarrowondisplay
tosavechangesandgotonextscreenmenu.
Time format
•Use(+)or(-)tochangesetting.•SelectEnteronthescreen
menutosavechangesandgobacktokeypadmainmenu.
Security options
Partialkeypadlock:basicfunc-tionsofthesparemainaccessible(pumpandlightoutputs),butitisimpossibletochangethetemperatureSetPoint,ortoenterprogrammingmode.Fulllock:allkeysaredisabled.Whenthekeypadislocked,theiconwillbedisplayed.
•SelectSecurityoptions
Partial keypad lockout
•Use(+)or(-)keytoselect"Partial".
•SelectEntertogobacktothekeypadmainmenu.
Tounlockthekeypad:•SelectModekey•PressandholdOptionkey
for5seconds
Full keypad lockout
•Use(+)or(-)keytoselect"Full".•SelectEntertogobackto
keypadmainmenu.
Tounlockthekeypad,pressandholdtheLightkeyfor5seconds.
System info
9919-100713-D Rev.06-2013 www.geckoalliance.com
©GroupeGeckoAllianceInc.,2013Alltrademarksorregisteredtrademarks
arethepropertyoftheirrespectiveowners.
PrintedinCanada06-2013
top related