product introduction of electro-hydraulic industry
Post on 21-Apr-2022
1 Views
Preview:
TRANSCRIPT
Product introduction of electro-hydraulic industry
Contents
1
3
2
EHS100 Integrated machine
SM SERVO MOTOR
SD650 Inverter
公司概况
EHS100 Integrated Machine
EHS100 Integrated Machine
EHS100: Model explanation
EHS100 - T 4 - XX (XXX) X
Code Rated speed (rpm)
A 1000
B 1500
C 1800
D 2000
Code Rated torque (N·m)
70 70
90 90
··· ···
Code Volt Phase
T Three phase
Code Voltage
4 400V
Product series
EHS100
EHS100: SISTEMA SERVO HIDRAULICO
PARA MAQUINAS INYECTORAS
145-185 N.m
27-35kw105 N.m
20kw48-90 N.m
9-17kw21-35 N.m
4.4-7.5kw9-15 N.m
2-3kw
EHS100: Top view of all series
9-15 N.m 21-35 N.m 48-90 N.m 105 N.m 145-185 N.m
Shaft diameter
20mm
Flange 110mm
Shaft diameter
42mm
Flange 180mm
Shaft diameter
42mm
Flange 180mm
Shaft diameter
48mm
Flange 250mm
Shaft diameter
35mm
Flange 114.3mm
EHS100: Specifications
ModelRated Torque
(N.m)
Rated Speed
(rpm)
Rated Power
(kw)
Maximum
Torque (N.m)
Maximum
power (kw)
Rated
current (A)
Flange
(mm)
Shaft diameter
(mm)
EHS100-T4-9D 9 2000 2 20 4 3.5110 20
EHS100-T4-14D 14 2000 2.9 29 6 5.4
EHS100-T4-21B 21 1500 3.3 53 8 6.4
114.3 35
EHS100-T4-21D 21 2000 4.4 45 9.4 8
EHS100-T4-26B 26 1500 4.4 65 10 7.9
EHS100-T4-26D 26 2000 5.5 50 11.7 11
EHS100-T4-35B 35 1500 5.5 88.8 13.9 10.6
EHS100-T4-35D 35 2000 7.5 65 13.9 14
EHS100-T4-48B 48 1500 7.5 96 15 14.5180 42
EHS100-T4-48C 48 1800 9 96 22.5 17
EHS100: Specifications
ModelRated Torque
(N.m)
Rated Speed
(rpm)
Rated Power
(kw)
Maximum
Torque (N.m)
Maximum
power (kw)
Rated
current (A)
Flange
(mm)
Shaft diameter
(mm)
EHS100-T4-70B 70 1500 10.4 132 20 19
180 42
EHS100-T4-70C 70 1800 13 152 28.9 23
EHS100-T4-90B 90 1500 14.6 186 29 27.5
EHS100-T4-90C 90 1800 17 177 34.3 32
EHS100-T4-105B 105 1500 16.5 210 33 30
EHS100-T4-105C 105 1800 20 216 41.2 36
EHS100-T4-145B 145 1500 22.7 290 45 41
250 48EHS100-T4-145C 145 1800 27 295 54.9 52
EHS100-T4-185B 185 1500 29 370 58 53.5
EHS100-T4-185C 185 1800 35 368 69.6 67
➢Drive part
➢Motor part
➢Cooling part
➢Braking part
Divided into four parts by
functions
Composition parts
Drive part Braking part Motor partCooling part
Left side of back view The front side of back view Right side of back view
Shaft
Lifting
ring
Signal
input
Brake
resistorDouble
channel fan
Power
Supplykeypad
Removable
footings
Product details
Shaft
Motor cable 3 lines, basically 5~10m, and the wiring need be through pipes
Temp cable 2 lines, basically 5~10m
Motor fan cable 2 lines, basically 5~10m
Encoder cable 6+1, basically 5~10m
DRIVE MotorBrake resistor 2 lines
Totally 15+1 cables, not include power cable and signal given cable
1. Control cabinet
2. Install drive
3. Install resistor
4. Install motor
5. Wiring
6. Debugging & auto-
tuning
Traditional Split inverter
install steps
1. System debugging free, no need auto-tuning, Power on and run.
2. No need to change the motor installation size and method.
3. Save the electric control cabinet.
4. No need to wire UVW line, Fan cable, Temp cable, encoder cable, brake cable.
The probability of wiring error is 0. Avoid the cost of error correction.
Integrated
machine
Easy to use Need more installation space and
heat dissipation distance
The internal wiring is helpful to improve the EMC of system.
Reduce the distributed capacitance between lines, greatly reduce the interference,
Improve the adaptability of system.
EHS100: Low noise to other devices
Split solution
Integrated solution
AC300~480V Power input
Wide AC input voltage range, calmly cope with
various harsh grid environment.
Improving the scope of application of equipment
in extreme conditions.
EHS100: Wide voltage input
Motor
FanDrive Fan
Motor air
duct
Drive air
duct
➢ Double independent air duct design, independent
operation
➢ The life time of Fan is 70000 hour (IP56)
➢ Multi point temperature monitoring and intelligent
control
➢ Monitoring the real time temp of drive and motor
separately
➢ Under the condition of low load or standby, the fan
operates intelligently
EHS100: Intelligent double air duct
➢ IPM Design of embedded magnetic steel
➢ Low temperature rise, fast response
➢ Support intermittent 2 times rated torque operation
EHS100: IPM (PMSM)
➢ Multiple linkage control modes
such as synchronization, master-slave follow,
intelligent tracking, etc.
➢ Support merging and diversion switching control
EHS100: Multi machine linkage by CAN bus
➢ Keypad adapt RJ45 standard network interface
➢ Long distance extension (Maximum 100m)
Keypad
bracket
Double Keypad
bracket
EHS100: Removable keypad
➢ Standard brake unit
➢ Adopt ceramic core aluminum shell resistor.
➢ Embedded brake software protection function
EHS100: Standard brake system
Cases
公司概况SD650 INVERTER
General parts of Hydraulic system
Motor
Pressure
Oil out flange
Oil in flange
Oil pump
CoupleBracket
Inverter
Brake resistor
SD650 System configurations
SD650: Model explanation
SD650 - T 3 - XXX X X
Code Cooling mode
AC Air cooling
LC Liquid cooling
CodeRated
torque(N·m)
70 70
90 90
··· ···
Code Volt phase
T Three phase
Code Voltage
3 400V
Product series
SD650
➢ Power(7.5~110KW)Integrated keyboard
Encoder interface
DP insert port/Terminal port
CAN communication
Parallel interface
Pressure feedback interface
Command interface
Analog output
Enable interface
IO terminal
Main circuit terminal
Metal process shell, durable
and strong anti-interference
All series built-in braking unit
SD650 Inverter
SD650 Inverter
➢ Special design for Electro-hydraulic industry
➢ High-strength metal body, strong shock resistance
➢ Pluggable terminals for easy wiring
➢ Strong and weak current isolation layout to improve stability
➢ Standard brake unit
➢ 400VAC / 220VAC voltage level
SD650: 400V
Model Power (KW) Rated Current (A) Dimensions (W*H*D)
SD650-T3-07R5AC 7.5 17
210*320*165SD650-T3-011AC 11 25
SD650-T3-015AC 15 32
SD650-T3-018SAC 18.5 38
SD650-T3-022AC 22 45
260*446*202SD650-T3-030AC 30 60
SD650-T3-037SAC 37 75
SD650-T3-045AC 45 90
320*568*272SD650-T3-055AC 55 110
SD650-T3-075SAC 75 150
SD650-T3-090AC 90 180390*621*565
SD650-T3-110AC 110 210
SD650: 220V
Model Power(Kw) Rated current (A) Dimensions (W*H*D)
SD650-T2-07R5AC 7.5 30 210*320*165
SD650-T2-011AC 11 42
260*446*202SD650-T2-015AC 15 55
SD650-T2-018AC 18.5 70
SD650-T2-022AC 22 80
320*568*272SD650-T2-030AC 30 110
SD650-T2-037AC 37 130
SD650-T2-045AC 45 160
390*621*312SD650-T2-055AC 55 200
SD650-T2-075AC 75 260
Cases
公司概况SM-Motor
SM-Motor
➢ Design of IPM embedded magnet steel
➢ Standard PTC, KTY temperature protection
➢ H grade high temperature resistant magnetic steel
➢ S1 working mode torque
➢ Air cooling and liquid cooling series
➢ Tamakawa encoder
➢ 400V / 220V
➢ More than 2 times of rated overload capacity
SM Motor: Model explanations
SM XX XX (XXX) X XX X X
Code Encoder
R Resolver
X without
Code Rated torque (N·m)
90 90
105 105
··· ···
Product series
EHS100
Code Install flange
18 180mm
25 250mm
25 ···
Code Cooling
F Air cooling
W Liquid cooling
CodeRatedspeed
15 1500
17 1700
20 2000
Code Volt level
C3 phase
220V
D3 phase
380V
ENCODER CABLE
ENCODER CABLE
Brake resistor
Signal conversion board
SD610AIN-1A/10V
Multi-pump flow-converging system
Multi-pump flow-converging / flow-dividing
system
Partner
Thank you
top related