prase media technologies | more value to your systems ... · web viewa range of networkable high...
Post on 26-Mar-2021
4 Views
Preview:
TRANSCRIPT
Tannoy VNETTM
A range of networkable High Definition Sound Reinforcement loudspeakers incorporating DSP
and Class D amplification.
Introduction
With undisputed expertise in the reproduction of sound, and constant development of its core technologies, Tannoy has maintained its position at the forefront of loudspeaker design and manufacture for the commercial installation market.
Crucial to that has been the continuous development of the patented Tannoy Dual ConcentricTM point source constant directivity drive unit. This class leading transducer design is the subject of ongoing development; incorporating the very latest materials and acoustic developments.
The highly experienced Tannoy engineering team has now integrated leading edge digital signal processing and electronic technologies into their high definition sound reinforcement (HDSRTM) loudspeaker designs. The amalgamation of these core strengths has led to the development of the self-powered VNETTM range of V Series - loudspeakers designed to form the complete installation solution.
All VNETTM enabled products feature high performance DSP, mains auto-sensing Class D amplification, network control and diagnostics.
A systems based solution with the ultimate in installation flexibility and premium audio quality.
The Product Range
VNETTM Networking System Overview
The loudspeakers are factory calibrated for optimum individual performance and then shipped with the VNETWARETM software package to facilitate easy on-site commissioning of the system. This intuitive Windows interface controls all of the critical install functions, as well as providing the interface for the ongoing monitoring of critical system status and performance data, all in real-time.
Implementation of the network could not be simpler; VNETTM will support ‘Free Network Topology’, using twisted pair cable & RJ45 connectors. Each loudspeaker will contain a unique address so no user input will be required to configure the network nodes. Each loudspeaker in the system can be individually optimised and acoustically profiled, taking into account its exact position within the venue relative to the room boundary, and its own performance relative to the acoustic properties of the room itself.
Bi-directional communication between speaker and a PC through via an RS485 interface enables access to each speaker for configuration. Speakers will maintain functionality in the event of a PC crash or fault occurring in another node on the network.
As well as offering real time system performance monitoring within the install venue, remote diagnostics and control are achievable via the Internet on a secure VPN connection or WLAN.
There are four speaker models – all developed from the Tannoy V Series:
VNET 12 – VNET 12HP – VNET 15 – VNET 300
Three subwoofers are also equipped with VNET to partner the speakers:
VNET 15BP – VNET 15HL – VNET 18DR
The Tannoy Dual Concentric™ - the driving force behind Tannoy High Definition Sound Reinforcement
Tannoy’s core technology, the Dual Concentric™, is unlike ordinary drive units in that it is effectively two drivers properly merged into one.
In nature all sounds emanate from a single point in space. The high frequency unit of the Tannoy Dual Concentric™, centrally mounted in the throat of the main mid/bass driver, is so positioned as to acoustically replicate this single point source.
This delivers an involving and natural sound with an incredibly wide imaging ‘sweet spot’, which serves to create an expansive soundstage with remarkably focussed placement of vocals and instrumentation. Important advantages of this configuration are the extremely long throw of information allied to superb detail and vocal articulation; essential elements of successful sound reinforcement installations.
The time coherent, point source and constant directivity nature of the dispersion characteristics of the Dual make it an accepted industry standard in audio monitoring. By exceeding the strict demands of the recording and mastering in the studio Tannoy can ensure that playback performance in installations, large and small, whether pre-recorded or live sound is strictly controlled to accurately reflect the artist and sound engineers’ skill.
What is a true point source?
Where the HF and LF are coincident in space/time Where integration between HF and LF are seamless Where phase response is flat through crossover frequencies
The Dual Concentric™ point source driver delivers:
A constant time delay, removing the need for separate HF delay lines that need careful and time consuming on-site adjustments
An exceptionally linear response with accurately reproduced harmonics Constant directivity that delivers an even response throughout listening
area with consistent performance in both the horizontal and vertical planes.
This controlled and even dispersion gives greater intelligibility, even in difficult acoustic spaces where the engineer can accurately target the sound from the speakers to cover all areas within the venue.
Better harmonic alignment resulting in superb vocal intelligibility within an accurate and natural overall sound
The VNETTM Module
Combining a switch mode PSU, PWM amplification, Networking Control and user configurable DSP functionality, the VNETTM module offers a fully integrated installation solution in a single High Definition Sound Reinforcement loudspeaker package.
VNETTM control functionality
User Control Functions
User DSP Switch on the rear panel has two settings: The Off position will contain only the factory default settings, optimised for a ‘free space’ environment, as well as critical crossover functions & frequency dependent dynamics. On will contain both factory settings and user control functionality
Identification Functions
Each device will have its own unique factory installed ID handle, so no user input will be required to physically address & configure the network nodes.
Speakers on the network are identified with these factory default names; these can be edited by the user to zone addresses.
Speakers identified on the network set up screen can be physically located on the network by selecting the ‘Flash’ function to activate an LED mounted on the front of the loudspeaker. If the loudspeaker is not actually ‘in the line of sight’, then the loudspeakers internal noise generator can be used as a locater.
Each device control panel will have a properties tab. The properties will consist of the following:
Model NameFactory set with product model name
Network Handle - read onlyA numerical value set at the time of manufacture to uniquely identify the device on the network
Device NameSpecific user defined name, such as ‘Prosc.Left’ or ‘Delay 1’
Firmware Version - read onlyA numerical value of firmware version running in the device
Configuration Name12 character name the user can define to describe the current settings (Such as ‘Live Mode’)
Current ‘Voice’ profile indication - read onlyA numerical value indicating the current speaker ‘voicing’ profile (factory set equalization, crossover, & dynamics functions). VNETTM allows software file uploading if a future modification to the ‘voicing’ is made.
VNET 300
Signal Processing
Gain Sectiono Input Gain Fader With Edit Box (-30 to +15dB in 0.2dB Steps)o Input Mute – On, Off
High – Pass Filter sectiono Frequency Spin / Edit Boxo Shape Drop-Down Box
Low – Pass Filter Sectiono Frequency Spin / Edit Boxo Shape Drop-Down Box
Equaliser Sectiono High Resolution Input EQ Curve Displayo Low Shelf Band
Frequency Spin / Edit Box Slope Spin / Edit Box Boost-Cut / Edit Box
o High Shelf Band Frequency Spin / Edit Box Slope Spin / Edit Box Boost-Cut / Edit Box
o Parametric EQ Bands (x 8) Frequency Spin / Edit Box Slope Spin / Edit Box Boost-Cut / Edit Box
Delay Sectiono Delay Spin / Edit Box (up to 180ms)
VNET 300
Monitoring Functions
During normal operation the speakers on the network will appear as minimised panels on the computer screen. These are laid out to reflect the physical layout of the speakers within the venue so that the user can monitor system status, component condition and can therefore identify any fault at a glance.
In the event of any unusual system behaviour the minimised panels can be expanded to reveal the following detailed information in real time:
Input clip indicator Output limiter bar graph meter (2) Heat sink temperature bar graph meter Amplifier clip indicators (HF & LF on full range units) Transducer Failure Indicators (HF & LF on full range units) Amplifier protect status indicator
VNETTM System screen – showing a sample 6 node set up, one monitor screen expanded.
VNET 300
VNET
VNETTM System Features
Integral amplification and signal processing
Class leading 96kHz DSP
High power Class D amplifiers
Universal mains input
Exceptional thermal efficiency – no fans required
Optimised driver protection and dynamics
Frees up processing power on OEM matrix / routers
Complete control
Intuitive real-time software interface
Complete system control and ongoing supervision capability
Potential for remote supervision & Control
Flexible configuration
VNETTM System Applications
Where critical performance and accuracy are required
High quality public address
Live sound reinforcement
Theme pubs / nightclubs
Theatre front of house and effects
Movie theatre / cinema
Side fill in large scale music reinforcement
Theme parks and leisure venues
Sports and multi-use stadiums
Audio visual
Houses of Worship
Loudspeaker specifications
MO
DEL
SYSTEMTYPE
DR
IVER
FREQ
UEN
CY
RESPO
NSE
(1)
±2dB
DISPER
SION
MA
X SPL
CR
OSSO
VERD
SP G
ENER
ATED
ENC
LOSU
RE
VNET 12 Full range 300mm (12”) 60Hz – 25kHz 90 123dB program 1.5kHz 36 litre vented
Dual ConcentricTM 126dB peak 18mm (¾”)
birch
VNET 12HP Full range 300mm (12”) 55Hz – 23kHz 75 126dB program 1.5kHz 36 litre vented
PowerDualTM 129dB peak 18mm (¾”) birch
VNET 15 Full range 380mm (15”) 50Hz – 23kHz 90 124dB program 1.5kHz 44 litre vented
PowerDualTM 127dB peak 18mm (¾”) birch
VNET 300 Full range 300mm (12”) 45Hz – 23kHz 70 128dB program 1.5kHz 63 litre vented
SuperDualTM 131dB peak 18mm (¾”) birch
VNET 15BP Band pass 380mm (15”) 35Hz – 150Hz - 127dB program
Variable LPF 100 litre vented
Subwoofer Bass unit 130dB peak 18mm (¾”) birch
VNET 15HL Horn loaded 380mm (15”) 48Hz – 250Hz - 130dB
programVariable LPF Horn loaded
Subwoofer Bass unit 136dB peak 18mm (¾”) birch
VNET 18BP Band pass 458mm (18”) 27Hz – 200Hz - 130dB program
Variable LPF 200 litre vented
Subwoofer Bass unit 136dB peak 18mm (¾”) birch
Electronic system specifications
MO
DEL
SYSTEMTYPE
INPU
T SESN
SETIVITY
OU
TPUT
POW
ER
(PRO
GR
AM
ME)
INPU
T IM
PEDA
NC
E
DISTO
RTIO
N
DA
MPIN
G
FAC
TOR
EFFICIEN
CY
VNET 12
Dual channel
Class D
1.4V (+5.5dBu)
400W LF
5.6kΩ unbalanced
11.2kΩ balanced
-
<0.05% @
1kHz -3dB
output(22kH
z bandwidth)
120 ref 8Ω
>85% typically
400W HF limited
VNET 12HP 700W LF
700W HF limited
VNET 15 500W LF
500W HF limited
VNET 300 800W LF
800W HF limited
VNET 15BP 600W
VNET 15HL 800W
VNET 18BP 1200W
DSP system specifications
MO
DEL
FOR
MA
T
SAM
PLING
FR
EQU
ENC
Y
DSP
DYN
AM
IC R
AN
GE
CO
MM
UN
ICA
TION
S
CO
MM
S FA
CILITIES
VNET 12
1 IN - 2 O
UT
96kHz
24 bit A/S-D
/Aw
ord length
3rd generation
SHA
RC
112dB(A
) typical
Serial – RS485
Proprietary m
essage format
All param
eters editable, Firm
ware
updatable
VNET 12HP
VNET 15
VNET 300
VNET 15BP
VNET 15HL
VNET 18BP
PSU specifications
MO
DEL
INPU
T VO
LTAG
E
SWITC
HIN
G
FREQ
UEN
CY
VOLTA
GE
SELECTIO
N
INPU
T C
ON
NEC
TOR
VNET 12 115/230V +10/-20%
192kHz
Syncronised to D
SP
Autom
atic 45 – 65H
z
Locking Speakon Pow
ercon
VNET 12HP
VNET 15
VNET 300
VNET 15BP
VNET 15HL
VNET 18BP
Tannoy Ltd, Coatbridge, North Lanarkshire, Scotland ML5 4TFTel: +44 (0) 1236 420199 Fax: +44 (0) 1236 428230
E-mail: enquiries@tannoy.com
Tannoy North America, 335 Gage Avenue, Kitchener, Ontario, CanadaTel: (519) 745 1158 Fax: (519) 745 2364
E-mail: inquiries@tannoyna.com
Tannoy Germany, Postfach 1461, 22904 Ahrensburg, DeutschlandTel: (+49) 41 02-88 83 93 Fax: (+49) 41 02-88 89 59