powerwall (-c, -e) installation - fronius draftt30 · powerwall part numbers: 1067000-00-c,...
Post on 25-May-2020
4 Views
Preview:
TRANSCRIPT
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E
POWERWALL (-C, -E) INSTALLATION - FRONIUS
WALL MOUNTING TRANSPORTATION
© 2017 Tesla
ONLY ATJOB SITE
10 mm17 mm (-C only)
T20T30DRAFT
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E
POWERWALL (-C, -E) CONNECTIONS - FRONIUS
Twis
ted
Pai
r+
Sh
ield
Powerwall Terminal Name Wire Color Wire Gauge Strip Length
(Powerwall Side)Fronius Inverter Terminal Name
Strip Length (Inverter Side)
Ground Green/Yellow 2.5—6 mm2 (14—10 AWG) 8—12 mm (5/16—1/2 in) BAT PE 15 mm (5/8 in)
DC Power + Red 2.5—6 mm2 (14—10 AWG) 12—16 mm (1/2—5/8 in) BAT + 15 mm (5/8 in)
DC Power — Black 2.5—6 mm2 (14—10 AWG) 12—16 mm (1/2—5/8 in) BAT — 15 mm (5/8 in)
Enable Orange 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) IO 1
Logic Power (+) Brown 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) + (12 V+)
Logic Return (—) White 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) — (12 V—)
Comm Hi (+) Blue 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) D+
Comm Lo (—) Yellow 0.2—1 mm2 (24—18 AWG) 7—9 mm (9/32—3/8 in) D—
DRAFT
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E
POWERWALL (-C, -E) COMM WIRING INSULATION - FRONIUS
DRAFT
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E
POWERWALL (-C, -E) DC WIRING - FRONIUS
Note: Use 15A inline PV fuses/Sunclix provided by Fronius
GND
DC +
BAT + BAT – BAT PE
DC –
Powerwall Thermal Controller board
Fronius Symo Hybrid DC Connectors
DRAFT
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E
POWERWALL (-C, -E) COMM WIRING - FRONIUS
D–13579 –– D –13579 ––
Notes: • Powerwall -E units include factory-installed cable connected to Thermal Controller board• Terminate shield at inverter only
COM LO (–)COM HI (+)LOGIC –LOGIC +ENABLE
SHIELD
Powerwall Thermal Controller board
Fronius Symo Hybrid DATCOM Connectors
–
+ +
– D –
D +
9
8
7
6
5
4
3
2
1
0
DRAFT
Powerwall Part Numbers: 1067000-00-C, 1067000-00-E
POWERWALL (-C, -E) SWITCH SETTINGS - FRONIUS
CAN-Modbus Switch Termination Switch
Address Switches
en-REV_01_170126
Communication Protocol Switch Position
Modbus (RS485) Right
Termination Switch Position
Termination WITH Modbus bias Bottom
Address Switch Switch Position
Switch 1 Right
Switch 2 Right
Switch 3 RightDRAFT