DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
CONSTRUCTION OF TOILETFACILITIES
Prepared by :
OIC, Assistant Secretary for Project Managem
ent
Regional Infrastructure Coordinator
EDMUND B. BILANG
Sheet Content:
Sheet No.:Sheet No.:
TSS
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
PROJECT NAME :
Regional DirectorAtty AMINOLA P. ABATON
GUILLERMO L. LEONARDO
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
LOCATION :
LTO REGINAL OFFICE No.9
TOILET FO
UN
DATIO
N PLAN
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
WF
WF
WF
WF
WF
WFWF
WF
WF
LENGTH
LENGTH / 4LENGTH / 4
TYPICAL DETAIL O
F BEAM
10mm stirrups spaced @ 5-.05 m5-.10 m5-.15 mrest @
.20 m
12 mm horizontal bars
12161
600600
4154
5154
1000
BUILD
ING
LINE
FIREW
ALL
2"X3" C
-PURLIN
S 1.2 THICK
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
FASCIA
FASCIA
FASCIA
TOILET RO
OF FR
AMIN
G PLAN
10961
800
250
800
2504
-12m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
7-1
6m
mØ
MATTIN
G B
ARS B
OTH
WAYS
PLAN
300 800
N.G
.L.
SEC
TION
4-1
2m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
F1-C
1
TRUSS D
ETAIL DIAG
RAM
6" CON
CRETEH
OLLO
W BLO
CKS
PRE-PAIN
TED R
IB TYPE ROO
FING
2" X 4" C-PURLIN
S
2" X 6" CHAN
NEL BAR R
AFTER
ORD
INAR
Y GU
TTER
FASCIA BOARD
250
NAT. GRD. LINE
FIN. GRD. LINE
FIN. FLR. LINE
600 VERIFY 200
150
mm
THK. C
HB W
ITH 1
0m
mØ
HO
R.AND
VER
TICAL B
ARS
@ 6
00m
m O
.C.
3-1
0m
mØ
LONG
BARS
450ELE
VA
TION
DIPOLOG CITY DISTRICT OFFICEUPPER TURNO , DIPOLOG CITY
AS SHOWN
LTO.9.C
R.P2.W
1.L1.1LTO
.9.CR
.P2.W1.L1.0
LTO.9.C
R.P2.W
1.L1.2
Submitted by:
Recomm
ending Approval:
Approved by:
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSA
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
850850
8501700
977 952 979
PW
D
765
600
1500 600
3308
RAM
P-UP
TOILET FLO
OR
PLAN
AA
B B
33048304
TOILET FLO
OR
PLAN
9379
4308
FRON
T ELEVATION
10104
1850 900
2750
2000
2734 360 1428 319
SE
E TR
USS-1
G.I. S
HEETS
FIRE
WALL
#26 CO
RR
UG
ATED
W.C
.
GU
TTER
FAS
CIA
TOILET ELEVATIO
N/SECTIO
N "B-B"
TOILET SECTIO
N "A-A"
1850651900
1850 900
2750
8891700W
.C.
LAV.
1729
260317293166
LEFT ELEVATION
RIG
HT ELEVATIO
N
5007
5007
33083308
900
6411157
600
600
2100
SCHED
ULE O
F DO
OR
S AND
WIN
DO
WS ( CLASS-A)
Regional DirectorAtty AMINOLA P. ABATON
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 BALANGASAN DISTRICT
PAGADIAN CITY
LTO.9.C
R.P4.N
1.L1.2
LTO.9.C
R.P4.N
1.L1.1
LTO.9.C
R.P4.N
1.L1.0
AS SHOWN
LTO.9.C
R.P4.N
1.L1.2LTO
.9.CR
.P4.N1.L1.1
LTO.9.C
R.P4.N
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSP
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
TO SEPTIC TAN
K
F.D.
F.D.
C.O
.
F.D.
TOILET SAN
ITARY LAYO
UT
10mm
Ø V
ER
TICA
L BARS SPAC
ED@
400mm
ON
CEN
TERS
10mm
Ø H
OR
IZON
TAL BARS
PLA
CE
D E
VE
RY
2 LAYER
S OF C
HB
11-10mm
Ø M
ATTIN
G BAR
SS
PA
CE
D E
QU
ALLY AS SH
OW
N
1024200
1024205
DIG
ES
TIVE
CH
AM
BE
R
LEA
CH
ING
CH
AM
BE
R
300
25
WA
TER
LEVELW
ATE
R LEVEL
AIR
SPAC
EA
IR S
PACE
500500
61
6" THIC
K CH
B
12mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
MA
NH
OLE
4" Ø P
VC
OU
TLET
1500
500
MA
NH
OLE
MA
NH
OLE
P1
400200
01:20
DE
TA
ILE
D P
LA
N O
F S
EP
TIC
TA
NK
5P1
400200
01:20
DE
TA
ILE
D S
EC
TIO
N O
F S
EP
TIC
TA
NK
4
205
128
LEA
CH
ING
CH
AM
BE
R
25
WA
TER
LEVEL
AIR
SPAC
E
300
10mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
4" Ø P
VC
OU
TLET
MA
NH
OLE
500
500
40002000
10001000
VENT STACK THRU ROOF
PLUMBING LEGEND:
VENT STACKVSVSTR
WM
GV
HB FWATER METER
HOSE BIBB
FAUCET
GATE VALVE
WC
CO URFDCLEAN-OUT
WATER CLOSET
FLOOR DRAINURINAL
LAVLAVATORY
CVCHECK VALVE
FCOFLOOR CLEAN-OUT
RDROOF DRAIN
CBCATCH BASIN
DSDOW
NSPOUTG.I.P.
GALVANIZED IRON PIPE
SPECIFICATION :
LICENSED MASTER PLUMBER.8. ALL W
ORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULYDOUBLE CHECKED TO ENSURE W
ATER TIGHT PLUMBING SYSTEM.7. ALL W
ORKS HEREIN SHALL BE DONE OF CLASS A WORKMANSHIP, PIPING SYSTEM MUST BE
OF A TYPICAL APPROVED TANK.6. SEPTIC VAULT SHALL BE W
ATER TIGHT. COMPLETE WITH THE NECESSARY REQUIREMENTS
1/2" diameter PVC PIPES.5. MAIN W
ATER SUPPLY PIPES MUST BE 1" diameter AND BRANCH SUPPLY PIPES MUST BE
4. ALL CLEAR WATER SUPPLY SYSTEM SHALL BE OF PVC PIPES, SCHEDULE 40, MOLDEX BLUE.
3. USE SANIMOLD BY MOLDEX PRODUCTS FOR SANITARY WASTE SYSTEM.
2. ALL MATERIALS TO BE USED SHALL BE OF BRAND NEW AND OF APPROVED TYPE FOR
LOCATION AND PURPOSE.
PHILIPPINE PLUMBING CODE AND WITH THE LOCAL SANITARY AGENCY.
1. ALL WORKS HEREIN SHALL BE DONE IN ACCORDANCE W
ITH THE PROVISION OF THE
Regional DirectorAtty AMINOLA P. ABATON
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 BALANGASAN DISTRICT
PAGADIAN CITY
AS SHOWN
LTO.9.C
R.P4.N
1.L1.2LTO
.9.CR
.P4.N1.L1.1
LTO.9.C
R.P4.N
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by:
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSE
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
ba
Sab
SS
S
LIGH
TING
LAYOU
T PLAN ( CLASS-B)
POW
ER LAYOU
T PLAN ( CLASS-B)
FRO
M ELEC
TRICALPO
WER
SOURCE
FRO
M ELEC
TRICALPO
WER
SOURCE
Legend & Sym
bols:
32 WATTS CIRCULAR FLUORESCENT LAMP
SSINGLE SW
ITCH
DUPLEX THREE PRONG-GROUNDED RECEPTACLE OUTLET
S3
TRIPLEX SWITCH
1x36 WATTS FLUORESCENT LAMP IN 0.30m. x 1.20m. FLUORESCENT
FIXTURE, MIRRORIZED REFLECTOR AND LUOVER
CONDUIT RUN EMBEDDED ON WALLS & CEILING
1.
All electrical w
orks herein shall be done in accordance with the provisions of
the latest edition of the Philippine Electrical C
ode, existing rules and
ordinances of the Local Governm
ent, and with requirem
ents of the Local
Power C
ompany.
2.
Type of power service shall be 2
30
volts, 2-w
ire, 60 hz., single phase, line
to ground.
3.
All w
irings shall be installed in standard PVC/R
SC pipes inside a concrete
structure and inside ceiling spaces.
4.
All m
aterials to be used shall be brand new and of approved type.
5.
Minim
um size of w
ire and conduit to be used shall be 2.0
mm
. sq. and 20
mm
. dia. respectively.
6.
Wherever required and necessary, pull boxes or junction boxes of proper
sizes shall be installed at convenient and inconspicuous locations, although
such boxes are not shown on the plan nor m
entioned in the specifications.
7.
The electrical works shall be done under the direct and im
mediate supervision
of a duly licensed electrical practitioner.
General notes:
Regional DirectorAtty AMINOLA P. ABATON
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 BALANGASAN DISTRICT
PAGADIAN CITY
AS SHOWN
LTO.9.C
R.P4.N
1.L1.2LTO
.9.CR
.P4.N1.L1.1
LTO.9.C
R.P4.N
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
CONSTRUCTION OF TOILETFACILITIES
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Sheet Content:
Sheet No.:Sheet No.:
TSA
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
PROJECT NAME :
Recomm
ending Approval:
Regional DirectorAtty AMINOLA P. ABATON
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
LOCATION :
LTO REGINAL OFFICE No.9 ZAMBOANGA CITY DISTRICT OFFICE
VETERANS AVE, ZAMBOANGA CITY
11250
5139
26506750
1575
3638
32994746
3225
FLOO
R PLAN
900
6411157
600
600
2100
SCHED
ULE O
F DO
OR
S AND
WIN
DO
WS ( CLASS-A)
11250
5139
1575
3638
32994746
3225
REFLECTED
CEILING
PLAN
3250
4023FRO
NT ELEVATIO
N
4023
21003250
4023
LEFT SIDE ELEVATIO
N
RIG
HT SID
E ELEVATION
4023
3250
4023
LON
GITU
DIN
AL SECTION
W.C
.W
.C.
W.C
.LA
V.
AS SHOWN
LTO.9.C
R.P1.N
1.L1.0
LTO.9.C
R.P1.N
1.L1.1
LTO.2.C
R.P1.N
1.L1.2
LTO.9.C
R.P1.N
1.L1.0LTO
.9.CR
.P1.N1.L1.1
LTO.9.C
R.P1.N
1.L1.2
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
CONSTRUCTION OF TOILETFACILITIES
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Sheet Content:
Sheet No.:Sheet No.:
TSS
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
PROJECT NAME :
Regional DirectorAtty AMINOLA P. ABATON
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
LOCATION :
LTO REGINAL OFFICE No.9 ZAMBOANGA CITY DISTRICT OFFICE
VETERANS AVE, ZAMBOANGA CITY
5139
3638
FOU
ND
ATION
PLAN
11250
2063
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
WF
WF
WF
WF
WF
WF
800
250
800
2504
-12m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
7-1
6m
mØ
MATTIN
G B
ARS B
OTH
WAYS
PLAN
300 800
N.G
.L.
SEC
TION
4-1
2m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
F1-C
1
250
NAT. GRD. LINE
FIN. GRD. LINE
FIN. FLR. LINE
600 VERIFY 200
150
mm
THK. C
HB W
ITH 1
0m
mØ
HO
R.AND
VER
TICAL B
ARS
@ 6
00m
m O
.C.
3-1
0m
mØ
LONG
BARS
450ELE
VA
TION
LENGTH
LENGTH / 4LENGTH / 4
TYPICAL DETAIL O
F BEAM
10mm stirrups spaced @ 5-.05 m5-.10 m5-.15 mrest @
.20 m
12 mm horizontal bars
PRE-PAIN
TED R
IB TYPE ROO
FING
2" X 4" C-PURLIN
S
2" X 6" CHAN
NEL BAR R
AFTER
ORD
INAR
Y GU
TTER
FASCIA BOARD
11250
5139
1575
3638
32994746
3225
RO
OF FRAM
ING
PLAN
2" X 6" CH
AN
NEL BA
R RAFTER
2" X 4" C-PU
RLINS
GU
TTER
GU
TTER
AS SHOWN
LTO.9.C
R.P1.N
1.L1.0LTO
.9.CR
.P1.N1.L1.1
LTO.9.C
R.P1.N
1.L1.2
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
CONSTRUCTION OF TOILETFACILITIES
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Sheet Content:
Sheet No.:Sheet No.:
TSE
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
PROJECT NAME :
Regional DirectorAtty AMINOLA P. ABATON
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
LOCATION :
LTO REGINAL OFFICE No.9 ZAMBOANGA CITY DISTRICT OFFICE
VETERANS AVE, ZAMBOANGA CITY
11250
5139
26506750
1575
3638
32994746
3225
POW
ER LAY O
UT PLAN
FRO
M ELEC
TRICALPO
WER
SOURCE
11250
5139
26506750
1575
3638
32994746
3225
LIGH
TING
LAY OU
T PLAN
SS
SS
FRO
M ELEC
TRICALPO
WER
SOURCE
Legend & Sym
bols:
32 WATTS CIRCULAR FLUORESCENT LAMP
SSINGLE SW
ITCH
DUPLEX THREE PRONG-GROUNDED RECEPTACLE OUTLET
S3
DOUBLE GANG SWITCH
1x36 WATTS FLUORESCENT LAMP IN 0.30m. x 1.20m. FLUORESCENT
FIXTURE, MIRRORIZED REFLECTOR AND LUOVER
CONDUIT RUN EMBEDDED ON WALLS & CEILING
1.
All electrical w
orks herein shall be done in accordance with the provisions of
the latest edition of the Philippine Electrical C
ode, existing rules and
ordinances of the Local Governm
ent, and with requirem
ents of the Local
Power C
ompany.
2.
Type of power service shall be 2
30
volts, 2-w
ire, 60 hz., single phase, line
to ground.
3.
All w
irings shall be installed in standard PVC/R
SC pipes inside a concrete
structure and inside ceiling spaces.
4.
All m
aterials to be used shall be brand new and of approved type.
5.
Minim
um size of w
ire and conduit to be used shall be 2.0
mm
. sq. and 20
mm
. dia. respectively.
6.
Wherever required and necessary, pull boxes or junction boxes of proper
sizes shall be installed at convenient and inconspicuous locations, although
such boxes are not shown on the plan nor m
entioned in the specifications.
7.
The electrical works shall be done under the direct and im
mediate supervision
of a duly licensed electrical practitioner.
General notes:
AS SHOWN
LTO.9.C
R.P1.N
1.L1.0LTO
.9.CR
.P1.N1.L1.1
LTO.9.C
R.P1.N
1.L1.2
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
CONSTRUCTION OF TOILETFACILITIES
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Sheet Content:
Sheet No.:Sheet No.:
TSP
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
PROJECT NAME :
Regional DirectorAtty AMINOLA P. ABATON
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
LOCATION :
LTO REGINAL OFFICE No.9 ZAMBOANGA CITY DISTRICT OFFICE
VETERANS AVE, ZAMBOANGA CITY
11250
5139
26506750
1575
3638
32994746
3225
PLUM
BING
LAY OU
T
VENT STACK THRU ROOF
PLUMBING LEGEND:
VENT STACKVSVSTR
WM
GV
HB FWATER METER
HOSE BIBB
FAUCET
GATE VALVE
WC
CO URFDCLEAN-OUT
WATER CLOSET
FLOOR DRAINURINAL
LAVLAVATORY
CVCHECK VALVE
FCOFLOOR CLEAN-OUT
RDROOF DRAIN
CBCATCH BASIN
DSDOW
NSPOUTG.I.P.
GALVANIZED IRON PIPE
SPECIFICATION :
LICENSED MASTER PLUMBER.8. ALL W
ORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULYDOUBLE CHECKED TO ENSURE W
ATER TIGHT PLUMBING SYSTEM.7. ALL W
ORKS HEREIN SHALL BE DONE OF CLASS A WORKMANSHIP, PIPING SYSTEM MUST BE
OF A TYPICAL APPROVED TANK.6. SEPTIC VAULT SHALL BE W
ATER TIGHT. COMPLETE WITH THE NECESSARY REQUIREMENTS
1/2" diameter PVC PIPES.5. MAIN W
ATER SUPPLY PIPES MUST BE 1" diameter AND BRANCH SUPPLY PIPES MUST BE
4. ALL CLEAR WATER SUPPLY SYSTEM SHALL BE OF PVC PIPES, SCHEDULE 40, MOLDEX BLUE.
3. USE SANIMOLD BY MOLDEX PRODUCTS FOR SANITARY WASTE SYSTEM.
2. ALL MATERIALS TO BE USED SHALL BE OF BRAND NEW AND OF APPROVED TYPE FOR
LOCATION AND PURPOSE.
PHILIPPINE PLUMBING CODE AND WITH THE LOCAL SANITARY AGENCY.
1. ALL WORKS HEREIN SHALL BE DONE IN ACCORDANCE W
ITH THE PROVISION OF THE
10mm
Ø V
ER
TICA
L BARS SPAC
ED@
400mm
ON
CEN
TERS
10mm
Ø H
OR
IZON
TAL BARS
PLA
CE
D E
VE
RY
2 LAYER
S OF C
HB
11-10mm
Ø M
ATTIN
G BAR
SS
PA
CE
D E
QU
ALLY AS SH
OW
N
1024200
1024205
DIG
ES
TIVE
CH
AM
BE
R
LEA
CH
ING
CH
AM
BE
R
300
25
WA
TER
LEVELW
ATE
R LEVEL
AIR
SPAC
EA
IR S
PACE
500500
61
6" THIC
K CH
B
12mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
MA
NH
OLE
4" Ø P
VC
OU
TLET
1500
500
MA
NH
OLE
MA
NH
OLE
P1
400200
01:20
DE
TA
ILE
D P
LA
N O
F S
EP
TIC
TA
NK
5P1
400200
01:20
DE
TA
ILE
D S
EC
TIO
N O
F S
EP
TIC
TA
NK
4
205
128
LEA
CH
ING
CH
AM
BE
R
25
WA
TER
LEVEL
AIR
SPAC
E
300
10mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
4" Ø P
VC
OU
TLET
MA
NH
OLE
500
500
40002000
10001000
AS SHOWN
LTO.9.C
R.P1.N
1.L1.0LTO
.9.CR
.P1.N1.L1.1
LTO.9.C
R.P1.N
1.L1.2
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSA
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
850850
8501700
977 952 979
PW
D
765
600
1500 600
3308
RAM
P-UP
TOILET FLO
OR
PLAN
AA
B B
33048304
TOILET FLO
OR
PLAN
9379
4308
FRON
T ELEVATION
10104
1850 900
2750
2000
2734 360 1428 319
SE
E TR
USS-1
G.I. S
HEETS
FIRE
WALL
#26 CO
RR
UG
ATED
W.C
.
GU
TTER
FAS
CIA
TOILET ELEVATIO
N/SECTIO
N "B-B"
TOILET SECTIO
N "A-A"
1850651900
1850 900
2750
8891700W
.C.
LAV.
1729
260317293166
LEFT ELEVATION
RIG
HT ELEVATIO
N
5007
5007
33083308
900
6411157
600
600
2100
SCHED
ULE O
F DO
OR
S AND
WIN
DO
WS ( CLASS-A)
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 DIPOLOG CITY DISTRICT OFFICE
UPPER TURNO , DIPOLOG CITY
Regional DirectorAtty AMINOLA P. ABATON
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
AS SHOWN
LTO.9.C
R.P2.W
1.L1.1
LTO.9.C
R.P2.W
1.L1.0LTO
.9.CR
.P2.W1.L1.2
HE
SH
E
LTO.9.C
R.P2.W
1.L1.1LTO
.9.CR
.P2.W1.L1.0
LTO.9.C
R.P2.W
1.L1.2
Submitted by:
Recomm
ending Approval:
Approved by:
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSP
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
TO SEPTIC TAN
K
F.D.
F.D.
C.O
.
F.D.
TOILET SAN
ITARY LAYO
UT
10mm
Ø V
ER
TICA
L BARS SPAC
ED@
400mm
ON
CEN
TERS
10mm
Ø H
OR
IZON
TAL BARS
PLA
CE
D E
VE
RY
2 LAYER
S OF C
HB
11-10mm
Ø M
ATTIN
G BAR
SS
PA
CE
D E
QU
ALLY AS SH
OW
N
1024200
1024205
DIG
ES
TIVE
CH
AM
BE
R
LEA
CH
ING
CH
AM
BE
R
300
25
WA
TER
LEVELW
ATE
R LEVEL
AIR
SPAC
EA
IR S
PACE
500500
61
6" THIC
K CH
B
12mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
MA
NH
OLE
4" Ø P
VC
OU
TLET
1500
500
MA
NH
OLE
MA
NH
OLE
P1
400200
01:20
DE
TA
ILE
D P
LA
N O
F S
EP
TIC
TA
NK
5P1
400200
01:20
DE
TA
ILE
D S
EC
TIO
N O
F S
EP
TIC
TA
NK
4
205
128
LEA
CH
ING
CH
AM
BE
R
25
WA
TER
LEVEL
AIR
SPAC
E
300
10mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
4" Ø P
VC
OU
TLET
MA
NH
OLE
500
500
40002000
10001000
VENT STACK THRU ROOF
PLUMBING LEGEND:
VENT STACKVSVSTR
WM
GV
HB
FWATER METER
HOSE BIBB
FAUCET
GATE VALVE
WC
CO URFDCLEAN-OUT
WATER CLOSET
FLOOR DRAINURINAL
LAVLAVATORY
CVCHECK VALVE
FCOFLOOR CLEAN-OUT
RDROOF DRAIN
CBCATCH BASIN
DSDOW
NSPOUTG.I.P.
GALVANIZED IRON PIPE
SPECIFICATION :
LICENSED MASTER PLUMBER.8. ALL W
ORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULYDOUBLE CHECKED TO ENSURE W
ATER TIGHT PLUMBING SYSTEM.7. ALL W
ORKS HEREIN SHALL BE DONE OF CLASS A WORKMANSHIP, PIPING SYSTEM MUST BE
OF A TYPICAL APPROVED TANK.6. SEPTIC VAULT SHALL BE W
ATER TIGHT. COMPLETE WITH THE NECESSARY REQUIREMENTS
1/2" diameter PVC PIPES.5. MAIN W
ATER SUPPLY PIPES MUST BE 1" diameter AND BRANCH SUPPLY PIPES MUST BE
4. ALL CLEAR WATER SUPPLY SYSTEM SHALL BE OF PVC PIPES, SCHEDULE 40, MOLDEX BLUE.
3. USE SANIMOLD BY MOLDEX PRODUCTS FOR SANITARY WASTE SYSTEM.
2. ALL MATERIALS TO BE USED SHALL BE OF BRAND NEW AND OF APPROVED TYPE FOR
LOCATION AND PURPOSE.
PHILIPPINE PLUMBING CODE AND WITH THE LOCAL SANITARY AGENCY.
1. ALL WORKS HEREIN SHALL BE DONE IN ACCORDANCE W
ITH THE PROVISION OF THE
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 DIPOLOG CITY DISTRICT OFFICE
UPPER TURNO , DIPOLOG CITY
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Regional DirectorAtty AMINOLA P. ABATON
AS SHOWN
LTO.9.C
R.P2.W
1.L1.1LTO
.9.CR
.P2.W1.L1.0
LTO.9.C
R.P2.W
1.L1.2
Submitted by:
Recomm
ending Approval:
Approved by :
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSE
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
ba
Sab
SS
S
LIGH
TING
LAYOU
T PLAN ( CLASS-B)
POW
ER LAYOU
T PLAN ( CLASS-B)
FRO
M ELEC
TRICALPO
WER
SOURCE
FRO
M ELEC
TRICALPO
WER
SOURCE
Legend & Sym
bols:
32 WATTS CIRCULAR FLUORESCENT LAMP
SSINGLE SW
ITCH
DUPLEX THREE PRONG-GROUNDED RECEPTACLE OUTLET
S3
TRIPLEX SWITCH
1x36 WATTS FLUORESCENT LAMP IN 0.30m. x 1.20m. FLUORESCENT
FIXTURE, MIRRORIZED REFLECTOR AND LUOVER
CONDUIT RUN EMBEDDED ON WALLS & CEILING
1.
All electrical w
orks herein shall be done in accordance with the provisions of
the latest edition of the Philippine Electrical C
ode, existing rules and
ordinances of the Local Governm
ent, and with requirem
ents of the Local
Power C
ompany.
2.
Type of power service shall be 2
30
volts, 2-w
ire, 60 hz., single phase, line
to ground.
3.
All w
irings shall be installed in standard PVC/R
SC pipes inside a concrete
structure and inside ceiling spaces.
4.
All m
aterials to be used shall be brand new and of approved type.
5.
Minim
um size of w
ire and conduit to be used shall be 2.0
mm
. sq. and 20
mm
. dia. respectively.
6.
Wherever required and necessary, pull boxes or junction boxes of proper
sizes shall be installed at convenient and inconspicuous locations, although
such boxes are not shown on the plan nor m
entioned in the specifications.
7.
The electrical works shall be done under the direct and im
mediate supervision
of a duly licensed electrical practitioner.
General notes:
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 DIPOLOG CITY DISTRICT OFFICE
UPPER TURNO , DIPOLOG CITY
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Regional DirectorAtty AMINOLA P. ABATON
AS SHOWN
LTO.9.C
R.P2.W
1.L1.1LTO
.9.CR
.P2.W1.L1.0
LTO.9.C
R.P2.W
1.L1.2
Submitted by:
Recomm
ending Approval:
Approved by:
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSS
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special ConcernsTO
ILET FOU
ND
ATION
PLAN
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
WF
WF
WF
WF
WF
WFWF
WF
WF
LENGTH
LENGTH / 4LENGTH / 4
TYPICAL DETAIL O
F BEAM
10mm stirrups spaced @ 5-.05 m5-.10 m5-.15 mrest @
.20 m
12 mm horizontal bars
12161
600600
4154
5154
1000
BUILD
ING
LINE
FIREW
ALL
2"X3" C
-PURLIN
S 1.2 THICK
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
FASCIA
FASCIA
FASCIA
TOILET RO
OF FR
AMIN
G PLAN
10961
800
250
800
2504
-12m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
7-1
6m
mØ
MATTIN
G B
ARS B
OTH
WAYS
PLAN
300 800
N.G
.L.
SEC
TION
4-1
2m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
F1-C
1
TRUSS D
ETAIL DIAG
RAM
6" CON
CRETEH
OLLO
W BLO
CKS
PRE-PAIN
TED R
IB TYPE ROO
FING
2" X 4" C-PURLIN
S
2" X 6" CHAN
NEL BAR R
AFTER
ORD
INAR
Y GU
TTER
FASCIA BOARD
250
NAT. GRD. LINE
FIN. GRD. LINE
FIN. FLR. LINE
600 VERIFY 200
150
mm
THK. C
HB W
ITH 1
0m
mØ
HO
R.AND
VER
TICAL B
ARS
@ 6
00m
m O
.C.
3-1
0m
mØ
LONG
BARS
450ELE
VA
TION
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9IPIL DISTRICT OFFICE
POB. IPIL, ZAMBOANGA SIBUGAY
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Regional DirectorAtty AMINOLA P. ABATON
AS SHOWN
LTO.9.C
R.P3.W
1.L1.2LTO
.9.CR
.P3.W1.L1.1
LTO.9.C
R.P3.W
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by:
Recomm
ending Approval:
Approved by:
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSA
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
Recomm
ending Approval:
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
850850
8501700
977 952 979
PW
D
765
600
1500 600
3308
RAM
P-UP
TOILET FLO
OR
PLAN
AA
B B
33048304
TOILET FLO
OR
PLAN
9379
4308
FRON
T ELEVATION
10104
1850 900
2750
2000
2734 360 1428 319
SE
E TR
USS-1
G.I. S
HEETS
FIRE
WALL
#26 CO
RR
UG
ATED
W.C
.
GU
TTER
FAS
CIA
TOILET ELEVATIO
N/SECTIO
N "B-B"
TOILET SECTIO
N "A-A"
1850651900
1850 900
2750
8891700W
.C.
LAV.
1729
260317293166
LEFT ELEVATION
RIG
HT ELEVATIO
N
5007
5007
33083308
900
6411157
600
600
2100
SCHED
ULE O
F DO
OR
S AND
WIN
DO
WS ( CLASS-A)
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Regional DirectorAtty AMINOLA P. ABATON
LOCATION :
LTO REGINAL OFFICE No.9IPIL DISTRICT OFFICE
POB. IPIL, ZAMBOANGA SIBUGAY
AS SHOWN
LTO.9.C
R.P3.W
1.L1.2
LTO.9.C
R.P3.W
1.L1.1
LTO.9.C
R.P3.W
1.L1.0
LTO.9.C
R.P3.W
1.L1.2LTO
.9.CR
.P3.W1.L1.1
LTO.9.C
R.P3.W
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSP
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
TO SEPTIC TAN
K
F.D.
F.D.
C.O
.
F.D.
TOILET SAN
ITARY LAYO
UT
10mm
Ø V
ER
TICA
L BARS SPAC
ED@
400mm
ON
CEN
TERS
10mm
Ø H
OR
IZON
TAL BARS
PLA
CE
D E
VE
RY
2 LAYER
S OF C
HB
11-10mm
Ø M
ATTIN
G BAR
SS
PA
CE
D E
QU
ALLY AS SH
OW
N
1024200
1024205
DIG
ES
TIVE
CH
AM
BE
R
LEA
CH
ING
CH
AM
BE
R
300
25
WA
TER
LEVELW
ATE
R LEVEL
AIR
SPAC
EA
IR S
PACE
500500
61
6" THIC
K CH
B
12mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
MA
NH
OLE
4" Ø P
VC
OU
TLET
1500
500
MA
NH
OLE
MA
NH
OLE
P1
400200
01:20
DE
TA
ILE
D P
LA
N O
F S
EP
TIC
TA
NK
5P1
400200
01:20
DE
TA
ILE
D S
EC
TIO
N O
F S
EP
TIC
TA
NK
4
205
128
LEA
CH
ING
CH
AM
BE
R
25
WA
TER
LEVEL
AIR
SPAC
E
300
10mm
Ø M
ATTING
BA
RS
SP
ACED
@400m
m O
NC
EN
TERS
3-10mm
.Ø H
OR
IZON
TALTE
MP
ER
ATU
RE BAR
S
MA
NH
OLE
4" Ø P
VC
OU
TLET
MA
NH
OLE
500
500
40002000
10001000
VENT STACK THRU ROOF
PLUMBING LEGEND:
VENT STACKVSVSTR
WM
GV
HB
FWATER METER
HOSE BIBB
FAUCET
GATE VALVE
WC
CO URFDCLEAN-OUT
WATER CLOSET
FLOOR DRAINURINAL
LAVLAVATORY
CVCHECK VALVE
FCOFLOOR CLEAN-OUT
RDROOF DRAIN
CBCATCH BASIN
DSDOW
NSPOUTG.I.P.
GALVANIZED IRON PIPE
SPECIFICATION :
LICENSED MASTER PLUMBER.8. ALL W
ORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULYDOUBLE CHECKED TO ENSURE W
ATER TIGHT PLUMBING SYSTEM.7. ALL W
ORKS HEREIN SHALL BE DONE OF CLASS A WORKMANSHIP, PIPING SYSTEM MUST BE
OF A TYPICAL APPROVED TANK.6. SEPTIC VAULT SHALL BE W
ATER TIGHT. COMPLETE WITH THE NECESSARY REQUIREMENTS
1/2" diameter PVC PIPES.5. MAIN W
ATER SUPPLY PIPES MUST BE 1" diameter AND BRANCH SUPPLY PIPES MUST BE
4. ALL CLEAR WATER SUPPLY SYSTEM SHALL BE OF PVC PIPES, SCHEDULE 40, MOLDEX BLUE.
3. USE SANIMOLD BY MOLDEX PRODUCTS FOR SANITARY WASTE SYSTEM.
2. ALL MATERIALS TO BE USED SHALL BE OF BRAND NEW AND OF APPROVED TYPE FOR
LOCATION AND PURPOSE.
PHILIPPINE PLUMBING CODE AND WITH THE LOCAL SANITARY AGENCY.
1. ALL WORKS HEREIN SHALL BE DONE IN ACCORDANCE W
ITH THE PROVISION OF THE
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Regional DirectorAtty AMINOLA P. ABATON
LOCATION :
LTO REGINAL OFFICE No.9IPIL DISTRICT OFFICE
POB. IPIL, ZAMBOANGA SIBUGAY
AS SHOWN
LTO.9.C
R.P3.W
1.L1.2LTO
.9.CR
.P3.W1.L1.1
LTO.9.C
R.P3.W
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSE
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special Concerns
ba
Sab
SS
S
LIGH
TING
LAYOU
T PLAN ( CLASS-B)
POW
ER LAYOU
T PLAN ( CLASS-B)
FRO
M ELEC
TRICALPO
WER
SOURCE
FRO
M ELEC
TRICALPO
WER
SOURCE
Legend & Sym
bols:
32 WATTS CIRCULAR FLUORESCENT LAMP
SSINGLE SW
ITCH
DUPLEX THREE PRONG-GROUNDED RECEPTACLE OUTLET
S3
TRIPLEX SWITCH
1x36 WATTS FLUORESCENT LAMP IN 0.30m. x 1.20m. FLUORESCENT
FIXTURE, MIRRORIZED REFLECTOR AND LUOVER
CONDUIT RUN EMBEDDED ON WALLS & CEILING
1.
All electrical w
orks herein shall be done in accordance with the provisions of
the latest edition of the Philippine Electrical C
ode, existing rules and
ordinances of the Local Governm
ent, and with requirem
ents of the Local
Power C
ompany.
2.
Type of power service shall be 2
30
volts, 2-w
ire, 60 hz., single phase, line
to ground.
3.
All w
irings shall be installed in standard PVC/R
SC pipes inside a concrete
structure and inside ceiling spaces.
4.
All m
aterials to be used shall be brand new and of approved type.
5.
Minim
um size of w
ire and conduit to be used shall be 2.0
mm
. sq. and 20
mm
. dia. respectively.
6.
Wherever required and necessary, pull boxes or junction boxes of proper
sizes shall be installed at convenient and inconspicuous locations, although
such boxes are not shown on the plan nor m
entioned in the specifications.
7.
The electrical works shall be done under the direct and im
mediate supervision
of a duly licensed electrical practitioner.
General notes:
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
Regional DirectorAtty AMINOLA P. ABATON
LOCATION :
LTO REGINAL OFFICE No.9IPIL DISTRICT OFFICE
POB. IPIL, ZAMBOANGA SIBUGAY
AS SHOWN
LTO.9.C
R.P3.W
1.L1.2LTO
.9.CR
.P3.W1.L1.1
LTO.9.C
R.P3.W
1.L1.0
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :
DEPARTMENT OF TRANSPORTATIONAND COMMUNICATIONS
Republic of the Philippines
Sheet Content:
Sheet No.:Sheet No.:
TSS
--
--
PSRA
F
NARTMT
OTNE
O
O
CDN
AT
RA
NOI
T
P
CI N U
AE
DS
NOI
T
MM
ATTY. EFREN C. MONCUPAUndersecretary for Project
Implem
entation and Special ConcernsTO
ILET FOU
ND
ATION
PLAN
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
F1 - C1
WF
WF
WF
WF
WF
WFWF
WF
WF
LENGTH
LENGTH / 4LENGTH / 4
TYPICAL DETAIL O
F BEAM
10mm stirrups spaced @ 5-.05 m5-.10 m5-.15 mrest @
.20 m
12 mm horizontal bars
12161
600600
4154
5154
1000
BUILD
ING
LINE
FIREW
ALL
2"X3" C
-PURLIN
S 1.2 THICK
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
TRUSS
FASCIA
FASCIA
FASCIA
TOILET RO
OF FR
AMIN
G PLAN
10961
800
250
800
2504
-12m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
7-1
6m
mØ
MATTIN
G B
ARS B
OTH
WAYS
PLAN
300 800
N.G
.L.
SEC
TION
4-1
2m
mØ
VER
T. BAR
S W
/ 10m
mØ
LATER
AL TIES
SPAC
ED; 3
@ 5
0m
m,
3@
100
mm
, 3@
150
mm
, REST @
200
mm
F1-C
1
TRUSS D
ETAIL DIAG
RAM
6" CON
CRETEH
OLLO
W BLO
CKS
PRE-PAIN
TED R
IB TYPE ROO
FING
2" X 4" C-PURLIN
S
2" X 6" CHAN
NEL BAR R
AFTER
ORD
INAR
Y GU
TTER
FASCIA BOARD
250
NAT. GRD. LINE
FIN. GRD. LINE
FIN. FLR. LINE
600 VERIFY 200
150
mm
THK. C
HB W
ITH 1
0m
mØ
HO
R.AND
VER
TICAL B
ARS
@ 6
00m
m O
.C.
3-1
0m
mØ
LONG
BARS
450ELE
VA
TION
Regional DirectorAtty AMINOLA P. ABATON
Prepared by :
Regional Infrastructure Coordinator
EDMUND B. BILANG
CONSTRUCTION OF TOILETFACILITIES
PROJECT NAME :
LOCATION :
LTO REGINAL OFFICE No.9 BALANGASAN DISTRICT
PAGADIAN CITY
LTO.9.C
R.P4.N
1.L1.2LTO
.9.CR
.P4.N1.L1.1
LTO.9.C
R.P4.N
1.L1.0
AS SHOWN
OIC, Assistant Secretary for Project Managem
ent
GUILLERMO L. LEONARDO
Submitted by :
Recomm
ending Approval:
Approved by :