p10(4)- nzm 10(4)-n/b nzm 10(4)-(n)(s)(h) /zm (m, v) … · current limiting data according to ul...
Post on 21-Sep-2018
217 Views
Preview:
TRANSCRIPT
K300-NZM 10K2x120-NZM 10K2x240-NZM 10RG-NZM 10K2x240W-NZM 10K2x240 IP-NZM 10
P10(4)-...NZM 10(4)-...N/BNZM 10(4)-...(N)(S)(H) /ZM (M, V)-...(-NA)
OFF
ON
TRIP
10 mm 5 mm
PZD 2Ø 2 mm
11/95 AWA123-1089
MontageanweisungInstallation InstructionsNotice d installation
Istruzioni per il montaggioInstrucciones de montaje
Electric current! Danger to life!Only skilled or instructed persons may carry out thefollowing operations.The national regulations/specificationes must be observed for the installation of the devices.
Tension lectrique dangereuse !Seules les personnes qualifi es et averties doivent ex cuter les travaux ci-apr s.Veuillez respecter les normes de mise en oeuvre sp cifiques aux diff rents pays.
Tensione elettrica: Pericolo di morte!Solo persone abilitate e qualificate possono eseguirele operazione di seguito riportate.Per l installazione degli apparecchi necessario rispettare le normative specifiche di ciascun paese.
`Corriente el ctrica! `Peligro de muerte!El trabajo a continuaci n descrito debe ser realizado por personas cualificadas y advertidas.Para la instalaci n de los aparatos han de tenerse encuenta las normativas/especificaciones a nivel local.
Lebensgefahr durch elektrischen Strom!Nur Elektrofachkr fte und elektrotechnischunterwiesene Personen d rfen die im Folgen-
den beschriebenen Arbeiten ausf hren.Beachten Sie f r die Installation der Ger te die l nder-spezifischen Vorschriften.
1/11
123-1089 06.02.2002 15:04 Uhr Seite 1
For Immediate Delivery call KMParts.com at (866) 595-9616
75
210
280
70
4P
4 M6x50
1:2
3P
143,
512
4
245
250
286
90°
90°
90°
90°
OFF
ON
TRIP
2/11
OFF
ON
TRIP
min. 130 mm
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 2
For Immediate Delivery call KMParts.com at (866) 595-9616
A
B
B
A
OFF
ON
TRIP
OFF
ON
TRIP
OFF
OFF
ON
TRIP
1 2
3
2 3
MontageMountingMontageMontaggioMontaje
AuslöseblockTrip blockUnité de déclenchementSganciatoreBloque de disparo
ZM (M)(V)/B1
3/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 3
For Immediate Delivery call KMParts.com at (866) 595-9616
OFF
ON
TRIP
OFF
ON
TRIP
A
B
OFF
ON
TRIP
I r
OFF
ON
TRIP
t r
OFF
ON
TRIP
I rmv
OFF
ON
TRIP
B-NZM
ZM...
4 5
1 2
3 4
EinstellungenAdjustmentsRéglagesRegolazioniRegulaciones
ZM (M)(V)/B
lr
6xlrtrtr=20s
tr=6s
Irm
Irmv
tv
I>
I>I>
lr
6xlrtrtr=20s
tr=6s
Irm
Irmv
tv
I>
I>I>
lr
6xlrtrtr=20s
tr=6s
Irm
Irmv
tv
I>
I>I>
4/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 4
For Immediate Delivery call KMParts.com at (866) 595-9616
TRIP
tripped
push to trip
OFF
TRIP
OFF
ON
TEST 1 TEST 2
OFF
ON
TRIP
A
B
OFF
ON
TRIP
t v
OFF
ON
TRIP
I rm
5 6
7 8
lr
6xlrtrtr=20s
tr=6s
Irm
Irmv
tv
I>
I>I>
lr
6xlrtrtr=20s
tr=6s
Irm
Irmv
tv
I>
I>I>
Thermisches Gedächtnis - Verbraucher- und AnlagenschutzNach Auflösung durch Überstrom ist der NZM 10 nach x Minuten wieder einschaltbereit.
Thermal memory - user/system protectionThe NZM 10 is ready for closing x minutes after it has beentripped due to overcurrent.
Mémoire termique - protection des récepteurs et installationsAprès déclenchement sur surcharge, le NZM 10 peut êtreréarmé au bout de x minutes.
Memoria termica - protezione utillizzatori ed impiantiA seguito di sgancio dovuto a sovracorrenti, l’NZM 10 puòessere reinserito dopo x minuti.
Memoria térmica - protección del usuario y del sistemaEl NZM 10 está perparado para cerrar x minutos después de haberse disparado por sobreintensidad.
5/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 5
For Immediate Delivery call KMParts.com at (866) 595-9616
OFF
ON
TRIP
OFF
SVB-NZM 10
OFF
ON
TRIP
A
B
OFF
ON
TRIP
A
B
OFF
ON
TRIP
B
OF
TRIP
A
Ø 6...8 mmmax. 3x
1
3
2
AnschlüsseConnectionsConnexionsCollegamentiConexiones
TEST 3
6/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 6
For Immediate Delivery call KMParts.com at (866) 595-9616
A
B
B
A10 mm
B
A
10 mm50 Nm
B
A
K22 x 21
K2 x 120 K2 x 240
K300
S S
S
K22 x 21 K300
K2 x 240K2 x 120
SteuerleitungenControl cablesCâbles de commandeCavi comandiCables de control
1 2
3 4
S: 1x 120-300 mm2
1x 50-240 mm2
S: 2x 50-240 mm21x 70-120 mm2
S: 2x 70-120 mm2
10x16x0,811x21x1,0
2(11x21x1,0)
7/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 7
For Immediate Delivery call KMParts.com at (866) 595-9616
B5 mm8 Nm
A
B5 mm8 Nm
A
B5 mm8 Nm
AB
5 mm8 Nm
A
C
B
A
5 mm8 Nm
C
1
1 2
1 2
K22x21-NZM10
K300-NZM10
K2x120-NZM10
8/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 8
For Immediate Delivery call KMParts.com at (866) 595-9616
B
A
10 mm50 Nm
B
A
8 mm50 Nm
B
C
A
B
A
B
C
A
1 2
3
1 2
K2x240-NZM10
K2x240IP-NZM10
9/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 9
For Immediate Delivery call KMParts.com at (866) 595-9616
A
B10 mm
C
AB
OFF
ON
TRIP
70
254
Ø 43
A
B
C
1 2
3 4
A
C
B
1 K2x240W-NZM10
RG-NZM10
10/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 10
For Immediate Delivery call KMParts.com at (866) 595-9616
Current Limiting Data according to UL 489
Instructions for Field WiringTerminal Kit System for NZM 10 (C)NA and NZM 10 N/B-NA
Circuit Breaker Threshold Current
Circuit Breaker Wire Size Max. A-Rating TighteningTorque
Intermediate Current FrequencyHigh Interrupting Capacity
Type
Bolt-onTerminal Cover (3) 2Z1213-651.28 L1; L2; L3 600 A 50 Nm
K2x240W-NZM 10K2x240IP-NZM 10Terminal Cover (3) 2Z123-651.28Insulating Plate (1) 4Z 123-651.1003
Auxiliary Terminal
2xAWG2-2x500MCM
AWG 18-14
50 Nm
1,2 Nm
Cu + Al
Cu only
Cu only
600 A
500 A
350 A
K2x120-NZM 10
Auxiliary Terminal
2xAWG3/0-2x250MCM
AWG 18-14
K300-NZM 10
Auxiliary Terminal
250MCM-500MCM
AWG 18-14
NZM10H 600
Max. FrameSize A
RMSSYMkA
PeakkA
I2dt103A2s
MAXIMUMRMSSYMkA
PeakkA
I2dt103A2s
MAXIMUMRMSSYMkA
60 HzVoltage (V)Peak
kAI2dt103A2s
MAXIMUM
39
39
39
125
65
42
200
100
50
34.0
42.0
40.0
2800
5500
5500
50.0
52.0
45.0
3500
6600
7200
55.0
61.0
48.0
4000
8000
8000
240
480
600
8 Nm
1,2 Nm
8 Nm
1,2 Nm
Moeller GmbH,Industrieautomation, 53105 Bonn' 2002 by Moeller GmbH
11/95 AWA123-1089 10004851/0013 FDPrinted in the Federal Republic of Germany (02/02)
nderungenvorbehalten
11/11
11/9
5 AW
A123
-108
9
123-1089 06.02.2002 15:04 Uhr Seite 11
For Immediate Delivery call KMParts.com at (866) 595-9616
top related