• Mountstoanyroofstructuralmember(truss,I-beam,concreteroof,etc.)• Singleholepenetrationof13/4"• Singlepersoninstallationwithstandardtools• ASSE1052approvedvacuumbreakerandbackflowpreventer• Commercialsillfaucetonpostforeasyaccess• Valvehasintegralvacuumbreakerandbackflowpreventer• Convertibletovandalproofloosekey• Designedtobeinstalledwithstandardconstructionmaterials(Unistrut,all-thread,etc.)• Repaircanbeeasilyaccomplishedatrooflevel• 3/4"gardenhosethreadsstandard• Heavydutybrassconstructionwithasatinnickelfinish• Heavydutygalvanizedpipeprovidesstabilityandiseasilymountedtotheroofmountingbracket• Adjustablebrackettoaccommodateroofanglesupto4/12
close-up view
4515East139thStreetGrandview,MO64030(800)362-9055Fax(800)362-1463www.PRIER.com
P-RH3 Mild Climate Roof HydrantWith Integral P-004 Vacuum Breaker
and Dual Backflow Preventor• Commercial/Industrial• Anti-Siphon• Wheel Handle Operated
Application
P-RH3-D
PRIER’sP-RH3MildClimateRoofHydrant provides ayearroundsourceofwatertoroofsurfacesinmildclimateareas.Thehydrant consists of a commercial sill faucetmountedontoapostforeasyaccess.Thehydrantvalveisconnectedtothesupplypipingintheheatedportionofthestructure.ThisvalvehasabuiltinvacuumbreakerthatmeetsASSE1052.
TheRoofMountingBracket enables the hydrant to bemountedtoanystructuralmemberwithrigidsupport, in-steadoftotheskinofthebuildinglikecompetitiveproducts.
Thisbracketrequiresonlyasinglepenetrationpointof13/4",andcanbemountedtoconcrete,wood,steel,I-beams,truss,perlinsorotherstructureswithstandardconstructionmaterials(Unistrut,all-thread,etc.).
FeaturesO
rdering
P-RH3LengthH1-FlushMountRoofHydrantH2-PostMountRoofHydrantH3-MildClimateRoofHydrantMB-RoofHydrantMountingBracket
ID Part No. Description1 314-0021 MountingBracket
2 314-0022 PipeBracket
3 314-0023 StandOff
4 314-0025 3/8"LockWasher
5 324-1006 3/8"FlatWasher
6 314-0024 3/8"ShoulderBolt
7 314-0027 3/8"Nut
8 314-0029 1/2"FlatWasher
9 314-0028 1/2"Bolt
10 314-0030 1/2"HexNut
11 P-004CP VacuumBreakerAssembly
12 231-0001 StemAssembly
13 C-134KT-805 OvalHandleandScrewKit
14 C-135KT-802 SeatWasherKit,1/4"LBeveled
15 C-134KT-803 StemPackingKit
16 C-134KT-804 LooseKeyConversionKit
17 390-1001 StemPackingOnly
18 C-108KT-808 LooseKeyonLanyard
19 310-1012 ValveStemCap
Bottom Bracket View Front Bracket ViewSide Hydrant View
47.00"
Replacem
ent Parts & Stem
sR
ough-In Dim
ensions
4515East139thStreetGrandview,MO64030(800)362-9055Fax(800)362-1463www.PRIER.com
FurnishandinstallModelP-RH3CommercialPostMountRoofHydrantmanufacturedbyPRIERProducts,Inc.Hydrantshallbeinstalledthrougha1¾”singlepenetrationintheroofandmountedtotheinteriorstructurewiththeUniversalRoofHydrantMountingBracket(P-RMB)provided.Thisbracketmustbemanufacturedofheavygaugepowdercoatedsteelandmustallowforadjustmenttomeetroofanglesupto4/12.Themountingbracketshallbemountedtoconcrete,aroofingtruss,steelI-beamorinteriorwallwithstandardconstructionmaterials(all-thread,Unistrutorother).Thehydrantshallhaveanintegralvacuumbreaker/backflowpreventerandbeapprovedundertheASSE1052standard.Thehydrantshallhavea3/4”inletandbemadeofbrasswithasatinnickelchromiumfinish.Theroofpenetrationistobesealedbytheroofingcontractorinaccordancewiththeroofingcodesandconditionsintheirmunicipality.