Options for Fast, Reliable Pesticide Residues Analysis in Food by Triple Quadrupole GC-MS/MS

Richard Fussell1

Vertical Marketing Manager, Food and Beverage Michael T. Hetmanski2, Cristian Cojocariu3, Victoria Bailey-Horne2, Dominic Roberts3 and Paul Silcock3 1Thermo Fisher Scientific, Hemel Hempstead, UK, 2 Food and Environment Research Agency (FERA), York, UK , 3Thermo Fisher Scientific, Runcorn, UK

PP71668-EN 0515S

2

Outline

• The analytical challenge

• User requirements for GC-MS/MS analysis of pesticides • Collaboration between Fera and Thermo Fisher Scientific;

method optimisation, results and learning experiences

• Latest GC-MS/MS developments • Summary

3

• Wide range of matrices • Food • Environment

• Wide analytical scope • Low limits of detection • High sample throughput • Fast turnaround • Low cost of analysis

Analytical Challenges

RT: 4.57 - 37.12

6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36Time (min)

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rela

tive

Abun

danc

e

6.32

6.59

4.63

7.00 11.13

10.12

11.9925.20

14.969.50 23.13 29.6117.388.89

12.207.315.77 19.1315.57 15.848.20

26.4712.87 17.9513.77 23.58

28.7125.3620.625.09 21.7023.8319.25

27.7724.12

35.78

34.8134.3932.9230.11 31.00

NL:3.94E8TIC MS 2july2104_011

4

Requirements for GC-MS/MS

• Selectivity

• High sensitivity for 2nd transition to enable identification of pesticides at low target concentrations

• Robustness in operation 24/7 and ease of use

• Reproducibility

• Software: Effective and ease of use

• Cost, maintenance and service

5

1. Sample Prep: March 24th 2. LC-MS Analysis: April 29th

3. GC-MS Analysis: June 17th 4. Data Processing/Analysis: July 15th

Typical Pesticides Workflow Register at www.chromatographyonline.com/LCGCwebseminars

6

Pesticide Analysis: Triple Quad GC-MS

Highly Selective Reaction Monitoring (SRM) Improved detection limits

7

Selectivity: SIM and SRM

DDE-p,p’, 0.05 mg/kg in green tea, 1.0 uL splitless injection

Ion ratio = 2.7 Ion ratio = 3.5

Thermo Fisher Scientific and Fera GC-MS/MS Collaboration (1)

9

Analysis of QuEChERS Acetonitrile by GC?

• High expansion coefficient-limited injection volume

• Offline solvent exchange - requires care to avoid losses of volatile or unstable pesticides

• LVI with higher capacity liners or liner packing materials, but potential for adsorption of pesticides?

• Will repeated injection of acetonitrile extracts lead to a decrease in column efficiency?

• How quickly will matrix extracts contaminate the GC-MS

system?

10

Evaluation of high sensitivity GC-MS/MS

• Thermo Scientific™ TSQ Quantum™ GC-MS/MS system

• Thermo Scientific™ Trace™ Ultra GC Chromatograph • Thermo Scientific™ TriPlus RSH ™ Autosampler • Column: TR-Pesticide (II), 30 m x 0.25 mm i.d., 0.25 µm film

• ‘test matrix’- fruit preserve

• 96 pesticides/metabolites:192 transitions

Evaluate direct analysis, of QuEChERS acetonitrile extracts

11

SRM chromatograms – 1µL splitless

Splitless injection (1 µL) of acetonitrile extracts (d-PSA clean-up) of fruit preserve spiked at 0.01 mg/kg (= 10 pg on-column)

184.95>92.88 219.95>1

Dichlorvos

6.44

Pirimiphos- methyl

290.09>233.07 305.10>290.09

21.05

148.97>69.98 148.97>104.98

Captan (0.02 mg/kg)

24.9

226.03>206.03 163.02>206.03

Cyfluthrin (0.02 mg/kg)

47.03

180.99>151.99 252.99>93.00

Deltamethrin 51.6

Courtesy of Fera, UK

12

Summary of validation data (1 µL splitless)

• QuEChERS extraction (citrate buffer/d-PSA) of fruit preserve

• Except chlorothalonil, recovery and % RSD data for the other 95 compounds met EU DG SANCO validation criteria

Results courtesy of Fera, UK

13

Robustness (1 year) of instrument performance

• TSQ Quantum XLS • Analysed ~ 200 batches of samples

• ~ 6000 matrix injections (PTV-backflush)

• Kidney, liver, fish, meat, crustaceans, milk

• Response does vary but is always sufficient

• Analytical capillary column not replaced

• 2 breakdowns requiring service engineer

Information courtesy of Fera, UK

Themo Fisher Scientific and Fera GC-MS/MS Collaboration (2)

15

Thermo Scientific TSQ 8000 GC-MS/MS

The new Trace 1300 Series offers the most versatile GC platform in the market, with unique “instant connect” modularity for ground-breaking ease of use and performance, setting a new era in GC technology

16

(No I/S)

Repeatability using the baffled liner

• [10ul (1/10 diln with EtAc] speed controlled solvent vent] • PTV Baffle Liner deactivated (Siltek),

Results courtesy of Fera, UK

17

Repeatability Using Asymmetric Liners

• QuEChERS extracts of baby food (no IS) • High number of injector parameters to optimise

Results courtesy of Fera, UK

18

Validation Results

Dichlorvos (m/z 185-93, 186.9-93)

Cyfluthrin (m/z 226.0-206.1, 163.0-127)

• Excellent results obtained • Cycle time approximately 40 minutes

(0.01 mg/kg, 10 pg on column) (0.001 mg/kg 2.5 pg on column)

Results courtesy of Fera, UK

19

QuEChERS- GC-MS/MS Workflow Validation

Matrix Recovery (%) %RSD Average No out-with

criteria Average No outwith

criteria Apple 95 3 4.7 0 Grapes 100 4 4.1 2 lettuce 104 10 4,0 0 Oats 96 16 5.9 0

• According to SANCO/12571/2013 criteria • Recovery 70-120 % , RSDr (<20%)

• Splitless (1 µL) with cyclo-liner

Preliminary Data

Results courtesy of Fera, UK

Thermo Scientific™ TSQ ™ 8000 Evo GC-MS/MS

21

Increasing Laboratory Productivity

• Decrease analysis time by shortening the GC run times. • More samples in less time.

• Increase the number of pesticides in a run. • More SRMs to accommodate within an analytical run.

• Improve selectivity for various matrices.

• Increased number of SRMs per compound.

• See beyond the targets. • Full Scan and SRM data acquisition in the same experiment.

Expect More Performance

22

Fast GC-MS Pesticide Residue Analysis

Challenges:

• Complexity of elution when using fast GC

• Large number of compounds (SRMs) in short time

• Many SRM transitions can result in sensitivity loss

Solution:

• High speed analyzer • Fast collision cell • Short SRM dwell times with very

short inter-scan delays

23

TSQ 8000 Evo GC-MS/MS

Expect More Capacity

• Analytical instrumentation:

TSQ 8000 Evo GC-MS/MS Pesticide Analyzer TRACE 1310 GC Gas Chromatograph TriPlus RSH Autosampler (liquid injection set-up)

• EvoCell

• Rapid, innovative collision cell technology • Increased method capacity • More compounds • More SRM transitions • Up to 4x more transitions whilst maintaining method sensitivity low analyte concentrations

24

Pesticide MRM Database

The problem:

• Growing list of target compounds require continuous adjustment to an existing SRM database.

• Some SRM transitions are not suitable for all matrices. Addition of new SRM transitions can be time consuming.

The solution:

• Automated SRM development with AutoSRM.

25

AutoSRM: Fast, Simple Route to Optimized SRM

1) Precursor ion selection

2) Product ion selection

3) Collision energy optimization

AutoSRM automates the development of SRM methodology

26

Highlights of AutoSRM

• Automates the following: • Creation of full scan, product ion scan, and SRM methods • Creation of sample sequences • Creation of data layouts for analyzing results • Selection of precursor, product, and collision energies

End result showing optimized transition

27

Timed-SRM: Using Dwell Times Efficiently

Classical segmented SRM

TSQ 8000 EVO timed SRM

Classical segmented SRM:

• Complex to set up • Wasted dwell time • Reduced sensitivity • Reduced tolerance to RT shifts

TSQ 8000 Evo timed-SRM:

• Automated set-up • Full optimized dwell time • Optimal sensitivity • Increased resistance to RT shifts

28

Increasing Laboratory Productivity

• Decrease the analysis time by shortening the GC run times. • More samples in less time. • More SRMIncrease the number of pesticides in a run. • s to accommodate within an analytical run.

• Improved selectivity for various matrices

• Increase the number of SRMs per compound.

• Seeing beyond the targets • Full Scan and SRM data acquisition in the same experiment.

29

Decrease the Analysis Time

RT: 4.57 - 37.12

6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36Time (min)

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Re

lativ

e A

bu

nd

an

ce

6.32

6.59

4.63

7.00 11.13

10.12

11.9925.20

14.969.50 23.13 29.6117.388.89

12.207.315.77 19.1315.57 15.848.20

26.4712.87 17.9513.77 23.58

28.7125.3620.625.09 21.7023.8319.25

27.7724.12

35.78

34.8134.3932.9230.11 31.00

NL:3.94E8TIC MS 2july2104_011

Full scan 144 pesticides in baby food @ 0.2 mg/kg TG-5 SILMS, 30m x 0.25 mm x 0.25 µm GC run time: ~37 min

30

Fast GC: 144 Pesticides in Baby Food

As more compounds are added to a single run, more complexity arises with the management of acquisition windows and compound co-elution. RT: 3.68 - 10.75

4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5Time (min)

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e Ab

unda

nce

8.68 8.819.31

8.96

6.789.10

4.66

8.258.007.78 8.49 9.61

7.927.61

9.687.00 7.31

6.56 8.236.83

7.096.08

7.46 9.958.045.956.36

5.25 6.28 10.359.58

7.165.22

4.90 5.43 10.055.894.10 5.68

4.46 10.574.44 5.113.74 3.99

NL:1.28E9TIC MS 2july2104_057_140704112840SRM acquisition of 144 pesticides in baby food @ 0.2 mg/kg

GC column: TG-5 SILMS, 20m x 0.18 mm x 0.18 µm, faster temperature ramp GC run time: <11 min

31

Increase Laboratory Productivity

• Decrease the analysis time by shortening the GC run times. • More samples in less time.

• Increase the number of pesticides in a run. • More SRMs to accommodate within an analytical run.

• Improved selectivity for various matrices

• Increase the number of SRMs per compound.

• Seeing beyond the targets • Full Scan and SRM data acquisition in the same experiment.

32

More SRM Transitions/Compound for More Confidence

Tecnazene in baby food at 0.01 mg/kg level

33

RT: 14.95 - 16.71

15.0 15.2 15.4 15.6 15.8 16.0 16.2 16.4 16.6Time (min)

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bund

ance

RT: 15.79AA: 4093580SN: INF

RT: 15.79AA: 1901556SN: INF

NL: 2.60E6TIC F: + c EI SRM ms2 246.000@cid28.00 [176.095-176.105] MS Genesis 19May2014_03

NL: 1.21E6TIC F: + c EI SRM ms2 317.800@cid20.00 [245.995-246.005] MS Genesis 19May2014_03

RT: 14.84 - 16.62

15.0 15.2 15.4 15.6 15.8 16.0 16.2 16.4 16.6Time (min)

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bund

ance

RT: 15.79AA: 3837740

RT: 15.79AA: 1690756

NL: 2.35E6TIC F: + c EI SRM ms2 246.000@cid28.00 [176.095-176.105] MS Genesis 19May2014_05

NL: 1.03E6TIC F: + c EI SRM ms2 317.800@cid20.00 [245.995-246.005] MS Genesis 19May2014_05

More Speed Maintaining the Sensitivity

DDE-p,p’ in green tea, 1917 SRMs Inj. 0.01 mg/kg on column

DDE-p,p’ in green tea, 44 SRMs Inj. 0.01 mg/kg on column

0.7 ms 27 ms

34

Linearity: Dichlorvos

• Dichlorvos peak area response over 0.5–10 ppb (mg/kg), matrix-matched standard (baby food).

• Chromatograms (quantification and confirmation ions) at 10 ppb level.

8 SRMs/compound

2 SRMs/compound R2= 0.998

R2= 0.997

35

Examples of Peak Area Repeatability: Fast GC method

Data analysis method maintenance

GC Performance Maintenance

MS Performance Maintenance

Acquisition Method Maintenance

Routine results

%RSD pesticides (0.001 mg/kg on column) baby food matrix ~144 compounds in <10 minutes

Compound % RSD (n = 10) BHC, Alpha 7.0 BHC, Beta 8.8 BHC, gamma 9.2 Chlorobenzilate 12.5 Chlorothalonil 12.6 Clomazone 6.3 Cyfluthrin peaks 1-4 9.3 DDE p, p 8.2 Dichlobenil 5.3 Dichlorvos 8.1 EPTC 5.3 Etridiazole (Terrazole) 4.6 Hexachlorobenzene 8.9 Methacrifos 7.6 Propachlor 11.0 Propham 11.5 Simazine 9.1 Tecnazene 5.6 Tefluthrin 7.0 Triallate 11.0

36

Comprehensive Detection of Pesticides in a Sample

• Targeted screening and quantification of a number of pesticides is important.

• Increased interest in screening the samples for additional compounds beyond a target list.

• Less common or new pesticides or unknown

metabolic/transformation products could be detected in addition to targeted compounds.

• This requires fast analytical instrumentation able to acquire both full scan and SRM/SIM data simultaneously.

37

Summing up

• Compound database management: • Auto-SRM automates SRM transitions development.

• Using the available dwell time wisely: • Timed-SRM ensures minimal loss of time spent to acquire data.

• Enhancing the number of compounds and increasing the number of SRM transitions per compound:

• EvoCell fast collision cell technology.

• Comprehensive detection of target pesticides and of additional contaminants potentially hazardous to human health:

• Simultaneous full scan and SRM/SIM data acquisition.

• A full validation of this fast method is ongoing and will be available soon.

Fast, easy, and robust pesticide analysis can be achieved using:

38

Thermo Scientific Food and Beverage Community

• View application notes, on-demand webinars, product information, and many more resources on our Pesticides and Food Communities Libraries:

www.thermoscientific.com/pesticides www.thermoscientific.com/foodandbeverage

39

Thank You for Listening

Questions?

Stay connected with us Twitter @ChromSolutions Chromatography Solutions Blog http://chromblog.thermoscientific.com/blog YouTube http://www.youtube.com/ChromSolutions Facebook http://www.facebook.com/ChromatographySolutions Pinterest http://pinterest.com/chromsolutions/

top related