nuclear, safety and protection catalogue_english 2012.pdf
Post on 06-Jul-2018
421 Views
Preview:
TRANSCRIPT
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
1/96
Camfil Farr Products and Services
Air filtration solutions for nuclear industry
Camfil Farr - clean air solutions
Safety and Protection
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
2/96
Dear Customers,
The entire Protection and Safety team is delighted to introduce you our new Camfil Farr edition
2012 catalogue.
Our experience feedback, the analysis of your needs and the increasingly demanding technical
requirements (earthquake, leak-tightness, specific particles and molecules) allowed us to develop
this catalogue which aim is to bring you the best solutions related to the constraints of the nuclear
industry.
We aim to be recognized as the first clean air solutions’ supplier, as part as our sustainable
development and by respecting our core values:
The COMMITMENT of our teams, which means we listen to you and provide advice, competency
and a quick, high-quality response that meets your expectations.
The DURABILITY of being a family group of over 3400 people in the world, based on nearly 50
years of honest relations serving you and meeting your requirements. Tomorrow, we will still be
here to bring you even more services.
TEAM WORK meaning quick responses to meet your needs in an irreproachable way guaranteeing
that our commitments are upheld. We continue to learn and share our ideas and knowledge with
you. There is only quality in each person.
CUSTOMER SATISFACTION, this is our only aim in our daily work: discovering your expectations
and bringing you the solutions that meet most your needs. You are the key focus of our development.
LOCAL PRESENCE, we can ensure a local presence thanks to our 23 factories, our 4 a high-
performance R&D centres, our 25 subsidiaries and distributors in over 50 countries.These values are based on:
• our skills in constantly developing new products to guarantee our filters and equipment
according to the most demanding specifications and standards CTHEN, NFX 44011,
NFM 62200…
• the reliability of our promises regarding the efficiency of our products, the very short
delivery deadlines and the quality and the traceability of our products thanks to our
ISO 9001 certification.
• services related to our filtration fleet managment and stock safety, to our “Camfil
School” training centre, to our specific offers of field technical assistance and
maintenance services for the installed equipment, etc.
Camfil is involved in the respect of the environment through its ISO 14001 and EN 16001
certifications.
Do not hesitate to contact our filtration experts or to consult our website www.camfilfarr.fr, for moreinformation. Camfil is at your service!
Thanks for the trust you give us every day. Looking forward to hearing from you! Happy reading!
Arnaud PAQUE
General Director
Saint Martin Longueau (Oise) factory 20,000 m².
The biggest filter manufacturing site in France
at your service.
Laboratory: chemical test
Sheet metal workshop: welding, assembly
Filter workshop: pleating
Technical department
Carbon workshop: carbon bench
You can find us on the
Internet:
www.camfilfarr.com
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
3/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com1
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
Protection and Safety
GENERAL SUMMARY
Introduction p. 2
•THE CAMFIL FARR GROUP•CAMFIL FARR AT YOUR SERVICE
•HISTORY
•QUALITY – SAFETY – ENVIRONMENT – ENERGY•CAMFIL FARR SOLUTIONS IN THE NUCLEAR INDUSTRY•THE UNIQUE SPECIFICATIONS OF OUR EQUIPMENT
Medium Efficiency p. 11
•CMJ VK100•PLEATED GLASS FIBER FILTER•CAMMETAL•TM CHOC 2-IN-1
•SPARK ARRESTING FILTERS
High Efficiency p. 17
•OPAKAIR HT120•POLY V-PACK CELLS 95% DOP
Very-High Efficiency p. 21
•GENERAL POINTS•DELTAFIL
•POLY V-PACK FILTERS•PTFE POLY V-PACK FILTERS•CTHEN VALIDATED SOFILAIR FILTERS•SETTLING TANK CANISTERS
Adsorption p. 31
•GENERAL POINTS•CAPTURING HYDROGEN FLUORIDE•CAPTURING RADIOISOTOPES•ACTICARB 4000•ACTIVATED CARBON V-PACKS•REINFORCED BARRELS OF ACTIVATED CARBON
FOR TRAPPING RADIOISOTOPES
•ACTICARB FOR TOXIC GASES•MOLECULAR FILTRATION QUESTIONNAIRE
Casings and filters forcontainment systems p. 41
•GENERAL POINTS
•VHE CASING PVC 5 m3
/h FILTERS•VHE CASING PVC 20-30-50 m3 /h FILTERS•VHE CASING PVC 30 m3 /h and 50 m3 /h FILTERS•VHE CASING METAL 30-70 m3 /h FILTERS•VHE CASING METAL 300 m3 /h FILTERS•50 m3 /h REMOTE HANDLING
AND RECHARGEABLE VHE FILTERS
•ACTIVATED CARBON FILTERS•SCHEMATIC DIAGRAM OF A STAINLESS STEEL CASING
FOR VHE OR ACTIVATED CARBON FILTERS
•STAINLESS STEEL CASINGS 5 m3 /hfor 3205.11.00 filters
•STAINLESS STEEL CASINGS 30 m³/h•STAINLESS STEEL CASINGS 70 m³/h•STAINLESS STEEL CASINGS 300 m³/h•FILTERS AND PUSH-PUSH SYSTEMS•FILTERS FOR TIGHTNESS ENCLOSURES•CASINGS FOR RADIOACTIVE CELLS•BSS DUCT CASINGS
Containment equipment p. 61
•GENERAL REMARKS
•TIGHT LOCK CASINGS UNIT TYPE BUTTERFLY VALVES•MULTICELL TYPE TIGHT LOCK CASINGS•MULTICELL TYPE TIGHT LOCK CASINGS CONNECTING
FLANGES
•ISOLATION DAMPERS•SPECIFIC SURFACE TREATMENT FOR TIGHT LOCK
CASING AND ISOLATION DAMPER
•OPERATING INSTRUCTIONS FOR FILTER CHANGE-OUT•BAG OUT PORT TYPE PLATFORMS•CRADLE PLATFORMS•CAM PLATFORMS
•CAGES•GAS ADSORBERS (SOFILTRAD model)
Equipment fortemporary ventilation p. 83
•MOBILE FAN FILTER CASINGS FOR NUCLEARDISMANTLINGE
Accessories p. 87
•ACCESSORIES•FILTRATION MEDIA Discs and Reels•MEMORY JOGGERS
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
4/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com2
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
The Camfil Farr Group…
Quick presentation of Camfil Farr
Camfil Farr around the world
NUMBER OF
EMPLOYEES: 526
SALES IN
SEK MILLIONS: 319
ASIA-PACIFIC
NUMBER OF
EMPLOYEES: 218
SALES IN
SEK MILLIONS: 770
OTHER MARKETS
HEADQUARTERS
PRODUCTION UNIT, INCL. SALES
SALES OFFICE
AGENT NUMBER OF
EMPLOYEES: 1,560
SALES IN
SEK MILLIONS: 2,345
EUROPE
NUMBERS OF
EMPLOYEES: 864
SALES IN
SEK MILLIONS: 1,046
AMERICAS
Our assets•About 50 years’ experience in the nuclear industry•Complete range of air filters – One single supplier to meet all your needs•Very-High Efficiency (VHE) filters certified for the nuclear industry by specific
tests
•Internal development of applications to measure particles and radioactivity•Camfil Farr production sites strategically located close to nuclear power
stations
•92 nuclear power stations in the world fitted with Camfil Farr material
•Welders qualified according to the current nuclear standards•All our equipment for the nuclear industry is manufactured according to
nuclear standards and quality assurance
Our resources•3,400 employees in the world•23 production sites•Branches in 25 countries•Agents in more than 50 countries
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
5/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com3
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
… at your service
TrainingCamfil Farr Academy, a recognizedtraining center
Become the air filtration specialist in yourcompany.
Contact us to receive the detailed programfor this training course:Certified training centreTel. : +33 (0)1 46 52 48 28Fax : +33 (0)1 47 60 17 81www.camfilfarr.com/ProduitsServices/ Centre-de-formationContact : françoise.perez@camfil.fr
Training on “Raising awareness for fieldstaff” – On-site• Handling filtration cells.• Advice on storage conditions.
• Unloading/loading actived carbon.• Recommended Maintenance of filtration
equipment.
We recommend monitored and regulartraining of your staff.
Make your life easier
Support and technicalassistance in the fieldOur team of engineers and qualified tech-nicians is at your service for:
Your new installations:• Assistance for assembling equipment
(Tight lock casings, SOFILTRAD iodinetraps, etc.).
• Assistance for the installation of filtra-tion items (carbon loading, implemen-ting filtering cells, etc.).
Maintenance:• Equipment diagnostics.
Keeping supplied equipment operating
CAMFIL FARR commits itself to ensuring the supply of many spare parts used in manu-facturing its equipment.
Camfil Farr maintains detailed record of all products supplied to your plant; making filter
maintenance and ordering of spare parts convenient and consistent.
Personalized deliverieson request• Regular scheduled replacement.• Special labelling requirements.
Spare parts: clamping frame Casing: identification plateFilter: controlling and traceability
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
6/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com4
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
History
The story starts in 1928. At that time MrPoelman was a chemical engineer andworked in a workshop for manufacturingcostume jewellery. He developed a pleatedpaper filter to protect workers from collo-dion (a mixture of ether, nitrocellulose, andethyl alcohol. During an exhibition, the
military became very interested in the po-tential uses of the filter. Mr Poelman thenstarted manufacturing filters for breathingmasks for the French army.
The company ULTRAFILTRES POELMAN was created in 1930.
During the 1930s and 1940s, the com-pany developed filter papers for militaryand civilian use. Thus, in 1935-1936,ULTRAFILTRES POELMAN equipped theMaginot line with filters and then civilianshelters. At the same time, Mr Poelmanbecame interested in air filtration for indus-trial customers. Thus, in 1953, the first fil-
ters for glove boxes appeared (derivativesof military cartridges) and the first filtersin the shape of V-packs. These filters usedmini-pleats pleated paper technology.
In the same year, the company becameSCHNEIDER-POELMAN.1954 marked the start of a co-opera-tion with CEA (Commisariat à l’EnergieAtomique).
At the same time, 1950 saw the creationof an “air filtration” department within theSOCIÉTÉ FRANÇAISE D’ACETYLÈNE(SFA), a branch of Soudure AutogèneFrançaise (Air Liquide Group).
In 1959 development began on a mediabased upon glass fiber. Prior to the use ofglass fibers; flammable cellulosic paperwas used for filtration media.
Saint Gobain was entrusted by the CEA todevelop this media as the result of a fire ata fuel reprocessing site.
The manufacture of the first cells started atthe SFA factory in 1963.
In 1967, SOFILTRA was created, from
a merger between the companies SAINTGOBAIN TECHNIQUES NOUVELLES andSFA.
In 1976, in order to counteract foreigncompetition, requested by the Frenchadministration and EDF, SOFILTRA andSCHNEIDER-POELMAN merged to createSOFILTRA-POELMAN. This new companythen brought together all the experiencealready acquired over several years interms of air filtration in a nuclear environ-ment with, on the one hand, the cage-ins-talled V-pack filter technology developedby Schneider-Poelman, and, on the other
hand, a system of tight lock casing cellsinherited from Sofiltra.
In 1990, the Saint Gobain group soldSofiltra-Poleman to Camfil in order to focuson its core glass business. This merger for-med SOFILTRA-CAMFIL.In 1994, the company was renamedCAMFIL. Finally, in 2001, following thebuyout of the American company FARR,Camfil became CAMFIL FARR, the worldleader in air filtration.
Since the 1970s, the development ofCAMFIL FARR has accompanied the de-velopment of researches and of the frenchnuclear industry with the manufacture ofproducts like Sofilair, CTHEN filters, prefil-ters, settling tank canisters, carbon filtersand casings.
SOFILTRA-POELMAN
ultrafiltres poelman
1928 : Mr Poelman, a chemical engineer in the chemical industry
specialising in jewellery, designed the first pleated paper filters to
protect workers from the smell of collodion. These filters were
later be used by the French army.
1959 : Saint Gobain and CEA
“Atomic Energy Commission” become
partners in order to develop a glass fiber
filter for the nuclear industry.
1977 : AREVA buys SGN
(Saint Gobain Nucléaire)
and baptises the newcompany: Société
Générale pour les
techniques Nouvelles
(SGN).
1976 : To meet the requirements of the vast
NPP programme demanded by the Frenchgovernment, EDF asks Saint Gobain to merge
the companies SOFILTRA and POELMAN.
1967 : Creation of
SOFILTRA by the
merger of the
companies SFA and
SGTN.
1930 : Creation of
ULTRAFILTRES POELMAN.1951 : Creation of an air filtration
department in the SOCIETE FRANCAISE
D’ACETYLENE, a branch of
LA SOUDURE AUTOGENE FRANCAISE.
1960 : In order to meet the
requirements of the French CEA,
creation of an air filtration
department (Saint Gobain Nuclear).
EDF
CEA
AREVA
SAINT GOBAINTECHNIQUES NOUVELLES
SFA AIR LIQUIDE
SAINT GOBAINNUCLEAIRE
SAINT GOBAINCORPORATION
From Poelman to Camfil Farr
From Zoéto the present dayThe story of nuclear power in France beganon 15th December 1948, when a teamof researchers led by Frédéric Joliot, wereawarded the Nobel prize for chemistry.They created the first French fuel cell, Zoé,by the fission of uranium atoms.
Zoé allowed initial studies to be carriedout on reactors, to produce radioelementsvital for research and to make all the mea-surements and all the experiments neededfor the design of the future fleet of Frenchnuclear reactors.
Since then, nuclear power has become areal industry with its specific points and itsspecific actors. These are involved in the
extraction of uranium ore, in the transfor-mation of this ore into enriched uranium,in the recycling of uranium or even, forexample, in the construction of nuclearpower stations or waste processing.
The main application of nuclear poweris for the production of electricity: Eightypercent of the electricity produced inFrance today comes from nuclear power.
However, with the progress of knowledge,new applications have appeared. So, to-day, nuclear power allows us to date, inparticular, natural phenomena thanks to
isotopic dating and offers a diagnostic pos-sibility thanks to medical imagery.
Camfil Farr FranceA 50 years experience in
the nuclear industry
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
7/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com5
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
Camfil Farr has been a major partner ofthe nuclear industry, since the end of the1950s, Camfil Farr has actively contribu-ted to equip the CEA basic nuclear ins-tallations, electricity production centres,military research centres, ion or particleaccelerators and power lasers for scientific
research.
Moreover, the equipment usually foreseenfor nuclear activity, by its design whichguarantees optimum containment, is usedin the high-tech pharmaceutical researchfield where it is necessary for work in P3to P4 category laboratories.
The main developments are:• Electricity production centres (900 /
1300 / 1450 MWE) and new genera-tion EPR (China, France).
• Saclay, Fontenay Atomic ResearchCentres.
• Very long and very short duration waste
storage centres.• Fuel reprocessing centres (France,
Japan).• Military research centre.• Particle accelerators (Cyclotron medical
& research).• Power laser for research (Laser Méga
Joule, LIL).• Microbiological research centre (life
science).
EDF chose to equip 78 nuclear reactorswith Camfil Farr solutions:
58 of these reactors are located in France.
There are:• 34 x 900 MW.• 20 x 1300 MW.
• 4 x 1450 MW.The others are located in Belgium, Swe-den, South Africa, South Korea, China andin Spain.
AREVA and its branches also trustCamfil Farr:
3 reprocessing centres, in particular, useour material:• Marcoule (France).• La Hague (France).• Tokai (Japan).
History
Main references
CAMFIL France was given the “AREVA Supplier” label for two years running.
In June 2010, AREVA awarded the CAMFIL company the “AREVA Supplier” labelduring an official ceremony.
With this label, created by the AREVA group in 2009, AREVA emphasized its tieswith partner companies that make a substantial contribution to the company’s suc-cess.
AREVA has renewed its trust in Camfil that had already been given this award theprevious year.
This label is based on nearly twenty five quality requirements and respect of sus-tainable development and competitiveness values.Investment in innovation and research as well as the attention given to safety, securi-ty and the environment were thus decisive points for the awarding of this distinction.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
8/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com6
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
Quality – Safety – Environment – Energy
Recognised and lastingknow-howCAMFIL is a partner in the French nu-clear development programme and todaybenefits from recognised expertise in theProtection and Security field. CAMFIL pro-
ducts have supported our clients in theirdevelopment from Very High Efficiency fil-ters to tight lock casings, the final barriersin nuclear installations.
For this we have a Quality culture acquiredover a long time based on manufacturingand verification processes, componentsand qualified personnel.
A Quality Management Systemthat complies with ISO 9001Today, Quality is not only linked to product
manufacturing but is also part of all thecompany’s processes (see chart).
Through ISO 9001 certification, we haveimplemented all the foundations of thequality management system in terms of:
Integrated Management Systems• System steering: this is described
through our management process. TheQSEE Manager runs this, in particular,via a network of QSE contacts integratedinto different departments.
• Resource management: the supportservices make available to Camfil Farr
skills adapted to making its productsand services and supply and maintainthe infrastructures needed for the com-pany to run efficiently.
• Documentation management: the qua-lity documentation is considered to be awork tool allowing us to standardise ourwork methods and promote adaptability.Records are made for our customers asa proof of their actual implementation.
• Traceability: the products are all putinto batches in relation to the manu-facturing order number and, for VeryHigh Efficiency products, a unique serial
number allows us to trace the produc-tion and verification operations.
• Measure, analyse, improvement: atthe different stages of the productionprocess, some controls are made byqualified staff with calibrated material,and the results of these controls areanalysed.
We have also focused on continuous im-provement principle the crowning achieve-ment of the Group’s industrial policy, the“Green Tornado”. The objective being tocontinuously improve ourselves in 4 prio-rity areas, which are:• security,
• quality and sustainable development,• service,• costs,while respecting the company’s funda-mental values.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
9/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com7
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
Far beyond Quality …a Sustainable DevelopmentPolicyThe Camfil FARR group declares its deter-mination to contribute every day to thequality of the air that we breathe andhas followed, for nearly half a century,the path of Sustainable Development.This approach can be seen in the settingup of a Sustainable Development Policy,Camfilcaring.
In 2009, the Camfil Farr group publishedthe First Sustainable Development Reportin the world on air filtration. This reportputs into words our response to the chal-lenges of air pollution and global warmingas well as the key focuses of the companyfor our employees, our clients and the
stakeholders.Therefore, it was quite natural for usto go beyond the system of QualityManagement.
Quality – Safety – Environment – Energy
Sustainable Development PolicyThe Saint-Martin-Longueau factory set upan Environment Management System andobtained ISO 14001 certification as soonas 2003.
The specific aspects of the ISO 14001standard are dealt with through identifica-tion procedures for environmental aspects,regulatory monitoring, waste processing,and prevention of risk situations whichcomplete the pre-existing provisions of thequality management, continuous improve-ment and process mastery systems.
In the same approach, concerned with thehealth and safety of our personnel and thecompanies working on our production site,we set up a Safety Management System inaccordance with standard OHSAS 18001and based on the permanent reviewing ofour Single Document.
Finally, in accordance with our environ-
mental policy, many actions have been im-plemented since 2006 in order to improvethe energy performance of our productionsite. This will can be illustrated by the set-ting up of an Energy Management System and being awarded EN 16001 certifica-tion in May 2011.
All these Management systems have beenintegrated (QSEE) in order to steer them asefficiently as possible.
For more information (ISO certificates,QSE manual, Sustainable Development
review, etc.) please go to:www.camfilfarr.com/Documentation
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
10/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com8
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
The Camfil Farr ADVANTAGES
CAMFIL FARR solutions in the nuclear industry
page 12 page 18 see general catalogue page 19 page 26
page 78 page 63 page 82 page 34 page 16
page 57 page 58 page 50 page 28 page 24
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
11/96
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com9
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
Guaranteed efficiencyDuring the design and the sizing of any item, it is essential to consider all the data foreach other item included in the filtration barrier.
For example, clamping equipment (tray, shafts, cams, etc.) is designed depending onthe mechanical performances of the filter components (frame, gasket, sealant, etc.). Theconsideration of all this data determines the sizing and the design of the casing gasketseat.
CAMFIL FARR designs, manufactures and controls all these items (filter, casing, anddamper) depending on the different requirements.
This ensures guaranteed results during in situ tests and the efficiency of the installationwhen operating.
N.B.: Our responsibility is expressly limited to all the CAMIL FARR model filtering barriers. In par ticular, it cannot,in any case, be claimed in the case of assembly with equipment from different brands.
The Camfil Farr ADVANTAGES
The unique specifications of our equipment
Temperature resistanceConsidering the importance of filtration barriers, the French authorities wanted to catego-rise filters equipping certain filtration levels as “Important Security Items” (decree dated10 August 1984).
For this purpose, the CTHEN (Centre Technique Homologations des Equipements Nu-cléaires – Technical Center for Nuclear Equipment Accreditation) had the authority overaccreditation of the equipment. CAMFIL FARR developed products able to meet theserequirements.
Moreover, CAMFIL FARR carried out a series of tests with IRSN on a filtration barrier(casing + filter), based on the CTHEN specifications. During this programme, other dyna-mic tests (combination of pressure – temperature) at values higher than those imposedby the CTHEN specifications were also carried out. That way, verifications of the overalltightness (internal/external) of casings are made.
Now, only these tests allow CAMFIL FARR to guarantee the temperature resistance ofa complete filtration barrier (filter + casing).
A filtration barrier is an operational device installed in a ventilation network. It is composed of afiltering item (filter), its casing, platform, casing, and dampers.
Seismic resistanceThe tests are made on a vibrating table, and the seismic resistance calculations for ourequipment allow CAMFIL FARR to define the different components of the filtration barrier
items.In case of seismic, the wave induced is transmitted to the floor or the walls of buildings.These are transmitted to the casing via different anchor points.
The shock waves that the filtering item (filter) is subject to are different to those of thefloor. Actually, they result from the intrinsic characteristics of the casing, i.e. its geometry,its mass, its materials, etc. The same goes for the shock waves that the damper is sub-ject to.
In fact, shock waves to the filter or the damper are the results of the concatenation ofseismic spectres and the intrinsic characteristics of the casing.
That is why validating the seismic resistance of a filtration barrier or a damper can onlybe made taking into account the filter + casing combination.
The technical data for each of the items making up this filtering barrier are vital for thecalculations allowing us to validate the seismic resistance.
For over 40 years, CAMFIL FARR has capitalised on all this technical data (real tests andcalculations) in order to meet your requirements.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
12/96
Notes
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com10
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
13/96
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com11
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
TM SHOCK 2 IN 1
page 15
CAMMETAL
page 14
PLEATED GLASS FIBER FILTER
page 13
CMJ VK100
page 12
CONTENTS
SPARK ARRESTER FILTERS
page 16
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
14/96
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com12
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
CMJ VK100
ADVANTAGES•Maximum arresting capacity•Can be used with high hygrometry•High airflows
•Fire classification M1
Media: Glass fiber (fire classification M1) with increasing density.
Frame: Frame made of shaped galvanized steel sheet metal closed by rivets.
Gasket: Soft alveolar polyvinyl chloride (PVC) 15x10mm or without a gasket depending on model.
Grid: Galvanized meshing 25x25 on each side.
EN 779 Efficiency: 2002: G3.
Gravimetric efficiency: 89%.
Eurovent efficiency 4/5: EU3.
Recommended final pressure drop: 250 Pa.
Maximum airflow: Nominal airflow.
Temperature: 60° C or 120° C maximum in continuous service depending on model.
Retention: Thanks to the growing density of the glass fibers making up the media and the impregnation of them with special oil, thesefilters have a high retention power that may reach 2000 gr/m².
Mounting systems: In tight lock casing, assemblabled frames or platforms.
Reference ModelDimensions
(WxHxD) mmEfficiency
EN 779 : 2002Media
area m2Airflow / Nominal P
m3 /h / PaTemperature
T°CGasket
Calorificpotential MJ
Unit masskg
Unit volumem3
1450.61.00 CMJSOFGLASS3 610x305x50 G3 0.2 2000 / 80 120 none 0.5 1.7 0.01
1450.62.00 CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 120 none 0.5 2.5 0.02
1450.97.00 CMJSOFGLASS3 610x305x50 G3 0.2 2000 / 80 120 PVC 1.7 0.01
1450.90.00 CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 120 PVC 2.5 0.02
1450.93.00 (a) CMJSOFGLASS3 610x305x50 G3 0.2 2000 / 80 120 PVC 1.7 0.01
1450.91.00 (a) CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 120 PVC 2.5 0.02
1450.65.00 (b) CMJSOFGLASS3 610x610x50 G3 0.4 4000 / 80 60 PVC 2.5 0.02
Other dimensions available on request.
(a) Models 1450.93.00 and 1450.91.00 are intended for equipping tight lock casings and so their gasket is on the upstream side and they are fitted with a prehension ring (on the side of 305
mm for 1450.93.00).
(b) Media and grids held upstream and downstream by hot melt adhesive lines.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
15/96
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com13
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
PLEATED GLASS FIBER FILTER
ADVANTAGES•Performance guarantee sheet
according to model
•Large filtering surface
•Media sealed into the frame•Very good mechanical rigidity
Applications: Prefiltration for High Efficiency and Very High Efficiency filters. Equipment for of air handling units.
Type: Pleated glass fiber filter.
Media: glass fiber (fire certification M1).
Sealant: Synthetic or polyurethane resin (fire classification M3) depending on model.
Frame: Galvanized steel, except 1413.12.00: stainless steel.
Gasket: Semi-ring Ø 15 mm in one single piece, made of neoprene foam or alveolar PVC 15x10 mm.
EN 779 2002 Efficiency: G3.
Gravimetric efficiency: 85%.
Eurovent efficiency 4/5: EU3.
Recommended final pressure drop: 500 Pa.
Maximum Airflow: Nominal Airflow.
Temperature: 60° C or 120° C maximum in continuous service according to type.
Mounting systems: In tight lock casings, assemblable frames or platforms.
Reference ModelDimensions
(WxHxD) mmEfficiency
EN 779 : 2002Media area
m2
Airflow /Nominal P
m3 /h / Pa
TemperatureT°C
Sealant GasketCalorificpotential
MJ
Unitmass
kg
Unitvolume
m3
1405.09.00 Glass fiber filter 495x495x50 G3 1.48 2300 / 50 60 Synthetic resin PVC 11 1.5 0.01
1413.01.00 Glass fiber filter 610x610x50 G3 2.27 3400 / 50 120 Polyurethane None 25 2.5 0.02
1413.02.00 Glass fiber filter 610x610x50 G3 2.27 3400 / 50 120 Polyurethane Neoprene 2.5 0.02
1413.09.00 Glass fiber filter 610x610x50 G3 2.27 3400 / 50 60 Synthetic resin PVC 14 2.1 0.02
1413.10.00 (a) Glass fiber filter 610x610x50 G3 2.27 3400 / 50 60 Synthetic resin PVC 14 2.1 0.02
1413.12.00 (a+b) Glass fiber filter 610x610x50 G3 2.27 3400 / 50 60 Synthetic resin PVC 14 2.1 0.02
1413.30.00 (a) Glass fiber filter 610x305x50 G3 1.38 1700 / 50 60 Synthetic resin PVC 7 1.4 0.01
(a) Ring for assembly in tight lock casings.
(b) Stainless steel frame.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
16/96
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com14
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
CAMMETAL
ADVANTAGES•Can be used at high temperature•Protects VHE filters
Applications: Installation in nuclear ventilation circuit for pre-filtration before VHE filters.
Type: Medium efficiency metal knit.
Media: Overlaying of metal knit (galvanized or stainless steel) layers.
Frame: Galvanized or stainless steel depending on model.
Gasket: Polyvinyl chloride (PVC) foam 15x10 mm or triangular compact silicon.
Grid: Galvanized or stainless steel depending on model.
Handle: Prehension ring (on the small side for 610x305 filters).
EN 779 2002 Efficiency: G3.
Gravimetric efficiency: 85%.
Eurovent efficiency 4/5: EU3.
Recommended final pressure drop: 200 Pa.
Maximum Airflow: Nominal Airflow.
Temperature: 120 or 200° C maximum in continuous service depending on model.
Mounting systems: In tight lock casings or platforms.
Reference ModelDimensions
(WxHxD) mmEfficiency
EN 779 : 2002Media area
m2Airflow / Nominal P
m3 /h / PaTemperature
T°CGasket
Calorificpotential MJ
Unit masskg
Unit volumem3
1460.01.01 TM Galva 610x610x50 G3 0.4 3400 / 55 120 PVC 5.4 0.02
1460.01.02 TM Galva 610x610x50 G3 0.4 3400 / 55 200 Silicon 5 5.4 0.02
1460.97.01 TM S/Steel 610x610x50 G3 0.4 3400 / 55 120 PVC 5.4 0.02
1460.97.02 TM S/Steel 610x610x50 G3 0.4 3400 / 55 200 Silicon 5 5.4 0.02
1464.11.02 TM Galva 610x305x50 G3 0.2 1500 / 45 200 Silicon 2.5 2.9 0.01
1464.11.03 TM Galva 610x305x50 G3 0.2 1500 / 45 120 PVC 2.9 0.01
1464.31.02 TM S/Steel 610x305x50 G3 0.2 1500 / 45 200 Silicon 2.5 2.9 0.01
1464.31.03 TM S/Steel 610x305x50 G3 0.2 1500 / 45 120 PVC 2.9 0.01
Other dimensions available on request.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
17/96
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com15
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
TM SCHOCK 2 IN 1
ADVANTAGES•Can be used at high
temperature
•Protects VHE filters
from sparks andglowing particles
Applications: Installation in nuclear ventilation circuit to protect VHE filters from sparks and incandescent particles.
Type: Combination of baffles and medium efficiency metal knit.
Media: Metal baffles and overlaying of metal knit (galvanized or stainless steel) layers.
Frame: Galvanized or stainless steel depending on model.
Gasket: Semi-ring Ø 15 mm in one single piece, made of neoprene depending on model.
Grid: meshing 25x25.
Handle: Prehension ring (on the small side for 610x305) filters).
EN 779: 2002 Efficiency: G2.
Gravimetric efficiency: 65%.
Eurovent efficiency 4/5: EU3.
Recommended final pressure drop: 200 Pa.
Maximum Airflow: Nominal Airflow.
Temperature: 120 or 200° C maximum in continuous service depending on model.
Mounting systems: In tight lock casings or platforms.
Reference ModelDimensions
(WxHxD) mmEfficiency
EN 779 : 2002Media area
m2Airflow / Nominal P
m3 /h / PaTemperature
T°CGasket
Calorificpotential MJ
Unit masskg
Unit volumem3
1465.60.08 TM Shock 2 in 1 S/Steel 610x305x50 G2 0.2 1500 / 380 200 - - 4.4 0.01
1465.60.12 TM Shock 2 in 1 S/Steel 610x610x50 G2 0.4 3400 / 380 120 Neoprene 2.9 8.8 0.02
Other dimensions available on request.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
18/96
Medium Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com16
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
SPARK ARRESTER FILTERS
ADVANTAGES•Can be used at high temperature•Protects VHE filters from sparks
and incandescent particles
Applications: Installation in nuclear ventilation circuit to protect VHE filters from sparks and incandescent particles.
Type: Medium efficiency metal knit.
Media: Overlaying of metal knit layers made of stainless steel.
Frame: Stainless steel.
Gasket: Semi-ring Ø 15 mm in one single piece, made of neoprene depending on model.
Grid: Meshing 25x25 and metal knit on the downstream side.
Handle: Prehension ring (on the small side for 610x305) filters).
EN 779: 2002 Efficiency: G3.
Gravimetric efficiency: 85%.
Eurovent efficiency 4/5: EU3.
Recommended final pressure drop: 200 Pa.
Maximum Airflow: Nominal Airflow.
Temperature: 120 or 200° C maximum in continuous service depending on model.
Mounting systems: In tight lock casings or platforms.
Reference ModelDimensions
(WxHxD) mmEfficiency
EN 779 : 2002Media area
m2Airflow / Nominal P
m3 /h / PaTemperature
T°CGasket
Calorificpotential MJ
Unit masskg
Unit volumem3
6271.98.00 S/S Spark Arrester 610X610X50 G3 0.4 1500 / 320 120 Neoprene 2.9 5.4 0.02
6271.99.00 S/S Spark Arrester 610X305X50 G3 0.2 3400 / 320 200 - - 2.9 0.01
Other dimensions available on request.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
19/96
High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com17
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
POLYV-PACK CELLS 95% DOP
page 19
OPAKAIR HT120
page 18
CONTENTS
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
20/96
High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com18
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
OPAKAIR HT120
ADVANTAGES•Large filtering surface•Long lifetime•High airflow
Applications: High Efficiency filter for new and transfer air circuit for nuclear industries.
Type: High Efficiency filter with a large filtering surface.
Media: Glass fiber paper (fire classification M1).
Separators: Glass fiber thread.
Sealant: Polyurethane.
Frame: Galvanized steel.
Gasket: EPDM gasket semi-ring diameter 15mm.
Handle: Only one 1514.12.00 and 1514.13.00.
EN 779: 2002 Efficiency: F7 and F8.
Spectral efficiency: 85 and 95%.
Eurovent efficiency 4/5: EU7 and EU8.
Recommended final pressure drop: 450 Pa.
Maximum Airflow: 1.10 x nominal Airflow.
Temperature: 120° C maximum in continuous service.
Mounting systems: In tight lock casings, platforms or “tub” type assemblable frames.
Reference ModelDimensions
(WxHxD) mmEfficiency
EN 779 : 2002Media area m2
Airflow / Nominal Pm3 /h / Pa
Calorific potentialMJ
Unit mass kg Unit volume m3
1514.52.00 OPAKAIR HT120 305x610x292 F7 10 2250 / 110 72 9 0.06
1514.12.00 OPAKAIR HT120 610x610x292 F7 20 4500 / 110 144 18 0.11
1514.53.00 OPAKAIR HT120 305x610x292 F8 10 2250 / 130 72 9 0.06
1514.13.00 OPAKAIR HT120 610x610x292 F8 20 4500 / 130 144 18 0.11
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
21/96
High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com19
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
POLY V-PACK CELLS 95% DOP
ADVANTAGES•Performance guarantee sheet•Large filtering surface
Applications: High Efficiency filter for new air and transfer circuits for nuclear industries.
Type: Poly V-pack High Efficiency filter.
Media: Glass fiber paper (fire classification M1).
Separators: Glass fiber thread.
Sealant: Polyvinyl chloride (PVC - fire classification M2).
Frame: Galvanized steel or stainless steel Z2 CN18-10 (304L) or Z8-C17 (F17) depending on model.
Gasket: Semi-ring Ø 15mm made of neoprene in one single piece.
Handle: 1 on side 610 parallel to V-packs.
DOP Efficiency 0.3 µm: 95%.
Eurovent efficiency 4/4: EU10.
Recommended final pressure drop: 600 Pa.
Mechanical resistance: 4000 Pa per airflow increase.
Maximum airflow: Nominal airflow.
Temperature: 120° C maximum in continuous service.
Mounting systems: In tight lock casings or platforms.
Reference ModelDimensions
(WxHxD) mmEfficiency
DOPMedia area
m2Airflow / Nominal P
m3 /h / PaFrame
Calorificpotential MJ
Unit mass kg Unit volume m3
1505.43.00 Galva poly V-pack 305x610x292 95% 20.5 1500 / 160 Galvanized steel 67 14 0.05
1506.47.00 Galva poly V-pack 610x610x292 95% 41 3400 / 160 Galvanized steel 128 23 0.11
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
22/96
Notes
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com20
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
23/96
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com21
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e s s o r i e s
SETTLING TANK CANITERS
page 29
SETTLING TANK CANITERS
page 28
DELTAFIL
page 23
CTHEN-APPROVED SOFILAIR
FILTERS
page 26
PTFE VHE POLY V-PACK FILTERS
page 25
VHE POLY V-PACK
page 24
CONTENTS
GENERAL POINTS
page 22
PRINCIPLESThe applications of VHE filters can beclassified in twov ery different categoriesdepending on therequired aim. Theseare:• obtaining an atmosphere witha very
low numericalconcentration in particlesorin micro-organisms forthe manufac-tureof very delicateproducts;
• arresting contaminants that aredange-rous forpeople, this is thecase withthenuclearindustry.
TECHNICAL SPECIFICATIONSRELATINGTO VHEFILTERSTheFrench specifications defined in “Theguidefor theventilation of nuclearinstalla-tions” mentions that thedecontaminationfactormeasured on thebenchtest forVHEfilters willbe, at nominalairflow, higher
than 5000 (efficiency over 99.98%)according to the sodium fluoresceinaerosol method fora median of Ø 0.15 µm (AFNOR standard NFX 44-011) andthat theadmissible finalpressuredrop willnot belowerthan 1000Pa.
This guidealso mentions, forinstallations,that thedecontamination factormeasuredon receipt and during operating has tobehigherthan the valueset by thetechnicalspecifications and in nocase lower than1000 withthe sodium fluorescein test(NFM 62-303standard).
Uranine test: fluorimetric method themeasuring of whichconsists in samplingth e u r an ine ae ro sol u p st r eam an ddownstream of thetest filter, using twosampling filters, to extract the uraninefrom these filters by washing and totitratethe washing solutions by measuringtheirfluorescence. The penetration of thefilter is theratio of thetiters of the twosolutions.
TheVHE filters must havesuccessfullyundergonequalification tests carried outin a laboratory of the Atomic EnergyCommission (CEA)or the Institute ofRadioprotection and Nuclear Safety(IRSN). They should tobe the subject of“PerformanceGuarantee” sheets based ontheresults of thesetests whichcovertheefficiency, thepressuredropand mechani-cal, thermalresistance, etc.
SOFILAIR CTHEN have been developedto meet specifica- tions ( including, inparticular, dynamic thermal resistancetests) established by theTechnicalCentreforthe Accreditation of NuclearEquipment(CTHEN). The Camfil FARR Air filtersSOFILAIR CTHEN were the firstonestobe accreditedat200°C/2h by CTHEN.AMERICAN SPECIFICATIONS listed inthe US Nuclear Regulatory Commission
Regulatory Guide1.52stipulatethat VHEfilters – HEPA Filters – should complywith American standards ASME AG-1(formerly military standard MIL-F 51.079forfilterpaper)and MIL -F-51.068forthefilter itself. Thelatter, whichis related tothe American design withdeep pleats,imposes minimum DOP efficiency of99.97% with 0.3 m icr on p a r t ic les .Moreover, it mentions thecriteria fornon-flammability, humidity and temperatureresistancethat the filters haveto meet.Fornuclearapplications, theRegulatoryGuide1.52 imposes metalframes.
T h e C amfi l F ARR VHE e xce e ds th erequirements of theFrenchand Americanstandards.
IRRADIATION RESISTANCEThemedia of ourVHE filters comply withthe American standard ASME AG1(MILF51079) whichallows us toguaranteetheirintegrity afteri rradiation (mechanicalresistance, tempe- rature resistance,waterresistance).
INTERNAL REQUALIFICATIONOurVHE filters are subject to completerequalification in theCAMFIL laboratory.This requalification includes alltheCEA orIRSN tests, humidity resistanceand atestforthe radiation resistanceof thesealants,gaskets and media. This regularrequalifi-cation allows us toguaranteethe integrityof ourfilters in extremeconditions.
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
24/96
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com22
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
C o n t a i n me n t e q u i p me n t
E q u i p m e n t f o r
A c c e s s o i r e s
PRINCIPLES
The applications of VHE filters can beclassified in two very different categoriesdepending on the required aim. These are:• obtaining an atmosphere with a very
low numerical concentration in particlesor in micro-organisms for the manufac-ture of very delicate products;
• arresting contaminants that are dange-rous for people, this is the case with thenuclear industry.
TECHNICAL SPECIFICATIONSRELATING TO VHE FILTERS
The French specifications defined in “Theguide for the ventilation of nuclear installa-tions” mentions that the decontaminationfactor measured on the benchtest for VHE
filters will be, at nominal airflow, higherthan 5000 (efficiency over 99.98%) ac-cording to the sodium fluorescein aero-sol method for a median of Ø 0.15 µm(AFNOR standard NFX 44-011) and thatthe admissible final pressure drop will notbe lower than 1000 Pa.
This guide also mentions, for installations,that the decontamination factor measuredon receipt and during operating has to behigher than the value set by the technicalspecifications and in no case lower than1000 with the sodium fluorescein test(NF M 62-303 standard).
Uranine test: fluorimetric method themeasuring of which consists in sam-pling the uranine aerosol upstream anddownstream of the test filter, using twosampling filters, to extract the uraninefrom these filters by washing and to ti-trate the washing solutions by measuringtheir fluorescence. The penetration of thefilter is the ratio of the titers of the twosolutions.
The VHE filters must have successfullyundergone qualification tests carriedout in a laboratory of the Atomic EnergyCommission (CEA) or the Institute ofRadioprotection and Nuclear Safety(IRSN). They should to be the subject of“Performance Guarantee” sheets based onthe results of these tests which cover theefficiency, the pressure drop and mechani-cal, thermal resistance, etc.
SOFILAIR CTHEN have been developedto meet specifications (including, in par-ticular, dynamic thermal resistance tests)established by the Technical Centre forthe Accreditation of Nuclear Equipment(CTHEN). The Camfil FARR Air filters SO-FILAIR CTHEN were the first ones to beaccredited at 200°C/2h by CTHEN.
AMERICAN SPECIFICATIONS listed in
the US Nuclear Regulatory CommissionRegulatory Guide 1.52 stipulate that VHEfilters – HEPA Filters – should comply withAmerican standards ASME AG-1 (formerlymilitary standard MIL-F-51.079 for filterpaper) and MIL-F-51.068 for the filteritself. The latter, which is related to theAmerican design with deep pleats, im-poses minimum DOP efficiency of 99.97%with 0.3 micron particles. Moreover, itmentions the criteria for non-flammabi-lity, humidity and temperature resistancethat the filters have to meet. For nuclearapplications, the Regulatory Guide 1.52imposes metal frames.
The Camfil FARR VHE exceeds the re-quirements of the French and Americanstandards.
IRRADIATION RESISTANCE
The media of our VHE filters complywith the American standard ASME AG1(MIL-F-51.079) which allows us to gua-rantee their integrity after irradiation
(mechanical resistance, temperature resis-tance, water resistance).
INTERNAL REQUALIFICATION
Our VHE filters are subject to completerequalification in the CAMFIL laboratory.This requalification includes all the CEA orIRSN tests, humidity resistance and a testfor the radiation resistance of the sealants,gaskets and media. This regular requalifi-cation allows us to guarantee the integrityof our filters in extreme conditions.
GENERAL POINTS
-
8/18/2019 Nuclear, safety and protection catalogue_English 2012.pdf
25/96
Very High Efficiency
CAMFIL FARR - 77/81, boulevard de la République - 92257 La Garenne Colombes Cedex - France
Tel. +33 (0)1 46 52 48 00 - Fax +33 (0)1 47 60 17 81 - www.camfilfarr.com23
C a m fi l F a r r r e s e r v e s t h e r i g h t t o m
o d i f y t h e c h a r a c t e r i s t i c s o f i t s p r o d u c t s w i t h o u t p r i o r n o t i c e w i t h i n t h e f r a m e w o r k o f i t s c o n t i n u a l i m p r o v e m e n t p o l i c y
f o r i t s p r o d u c t s .
I n t r o d u c t i o n
M e d i u m
E f fi c i e n c y
H i g h E f fi c i e n c y
V e r y H i g h E f fi c i e n c y
A d s o r p t i o n
C a s i n g s a n d fi l t e r s
f o r c o n t a i n m e n t s y s t e m s
C o n t a i n m e n t e q u
i p m e n t
E q u i p m e n t f o r
t e m p o r a r y v e n t i l a t i o n
A c c e�
top related