NIBE™ VVM 310FLEXIBLE INDOOR MODULE
INTELLIGENT HOT WATER
• Completeall-in-oneindoormoduleforheatingandhotwater.
• Forupgradingexistingheatingsystems(perhapsapool/existingboilercanbecombined)ornewbuildswithrequirementsforhighhotwaterperformance.SwedishNationalBoardofHousing,BuildingandPlanning'sBuildingRegulationsadaptedcontrols.
• NIBE'sair/waterheatpumpstogetherwithVVM310makeupacompleteinstallationforheatingandhotwater.
• Anewgenerationcontrolmodulewithacolourdisplayandseveralnewfunctions.
• NIBEUplinkTM
• Simpleconnectionandcontroloftheexternalheatsource(wood/oil/gas).Stepcontrolledadditionalheatwithimmersionheater.
• Integratedbuffertankfortheheatingsystem.
• Hotwatercoilmadeofstainlesssteel.
• Climatecontrolledautomaticshuntvalvethattakestheoutdoortemperatureintoconsideration.
• Self-regulating,speedcontrolled,chargerespectivelyheatingmediumpumpofA-classdesign.
• Loadmonitorasstandard.
NIBE VVM 310VVM 310 is a flexible indoor module and together with the NIBE's air/water outdoor modules creates a complete system to supply the building's heating and hot water requirements. VVM 310 can re-ceive energy from several different alternatives, for example from the F2030 and F2040 outdoor air heat pumps. It is also possible to supplement with energy from the existing boiler instead of using the internal immersion heater.
-FL2
-CM1
-EB15
-FL1
-QM40-RM1
-RN10-EB101
XL2
XL1-HQ1
-QM1
-QM41
-FL10
-QM40
-EB101
2 NIBE VVM 310
System diagram
Basic docking with hot water and a heating system
HOW THE NIBE™ VVM 310 WORKS
VVM 310 is designed for connection and communication with NIBE's air/water heat pumps. NIBE's air/water heat pumps to-gether with VVM 310 make up a complete heating installation and cover the majority of the heating and hot water demand. If the outdoor temperature drops to a level below the stop tem-perature of the heat pump all heating then occurs with VVM 310.
Together with F2030, buildings with a heating requirement of 15 kW in climates with DUT hotter than -25°C can be satis-fied. With lesser heating requirements, use system F2040. NIBE's VPDIM dimensioning program is recommended for correct di-mensioning of the building's heating output requirements and climate. Hot water capacity is dependent on selected outdoor
module and whether addition is permitted. For example for sys-tem F2030-VVM310 tap volume 240 litres (40 °C) at 12 l/min applies when the tank is charged at only F2030.
When combined with an outdoor pool used in the summer sea-son, system F2030-VVM 310 does not usually need to be dimen-sioned up with regard to the size of the outdoor section. This is because the building's heating requirement is less in the summer time and F2030's output and efficiency increases with warmer outdoor temperatures. A system with VVM 310 and NIBE's air/water heat pumps gives full flexibility. Even if pool heating or other external heat sources were not included at installation, VVM 310 is prepared when that is required.
NIBE VVM 310 3
R
0
+ 20-2
1
R
0
H M flo w4 9 (5 0 ) °CH o t w a te r 5 1 °C
+20
-2
1 R0
HM flo
w49 (
50) °C
Hot w
ater5
1 °C
R0
500
GOOD TO KNOW ABOUT NIBE™ VVM 310
LEK
LEK
LEK
Transport and storageVVM 310 must be transported and stored upright and dry.When being moved into a building, the VVM 310 may, however be carefullylaid on its back.
Quick and simple installation• No extra buffer tank for the heating system is required, be-
cause VVM 310 has full control of the heat pump and the heating system.
• New control with colour display and USB port.
• Installation help with step by step guide through the start-up process.
• Automatic setting of flow across heat pump and heating sys-tem.
• Factory installed components for best operational reliability and safe installation.
AssemblyPosition VVM 310 on a firm base that can bear its weight, prefer-ably on a concrete floor or foundation. Use the product's adjust-able feet to obtain a horizontal and stable set-up. The area where VVM 310 is located must be equipped with floor drainage.
Installation areaLeave a space of 500 mm in front of the product. All service on VVM 310 can be carried out from the front.
NOTE! Leave 10 - 25 mm free space between the indoor module and the wall behind for routing of cables and pipes.
Supplied components
The kit of supplied items is placed on top of the product.
Outdoor sensor Current sensorRoom sensor
4 NIBE VVM 310
XL18 XL19
XL1 XL8
XL4XL2 XL9XL30 XL3
Pipe dimensions
GOOD TO KNOW ABOUT NIBE™ VVM 310
MaintenanceA minimum level of maintenance is required. Only safety valves require checking. All essential components can be accessed from the front. This facilitates service and maintenance.
InstallationVVM 310 is easy to install. All pipe connections are easily accessi-ble. This is especially useful for the replacement market.
EquipmentVVM 310 is equipped with a drain and reversing valve. In ad-dition, VVM 310 is equipped with climate controlled automat-ic bypasses with outdoor and supply temperature sensors, shunt valve, charge and circulation pump.
Expansion vesselDimensioned as 5 % of the maximum system volume (that is 250 litres plus maximum circulating volume in the heating cir-cuit). Equip the product with safety valve and expansion vessel, as these are not supplied with the product at delivery.
DesignVVM 310 is equipped with an intelligent control. This makes for easy operation at the same time as always enabling the indoor module to run as efficiently as possible. The control also manages the automatic bypass and circulation pumps. Current tempera-tures and set values can be shown on the display. The insulation is polyurethane, which provides excellent heat insulation. The outer casing is of white powder-coated steel plate.
Connection
XL1 Heating medium, supply G20 int.
XL2 Heating medium, return G20 int.
XL3 Cold water G20 int.
XL4 Hot water G20 int.
XL8 Connection, docking in heating medium G20 int.
XL9 Connection, docking out heating medium G20 int.
XL18 Connection, docking in high temp Ø 22 mm
XL19 Connection, docking out high temp Ø 22 mm
XL30 Connection, expansion vessel G20 int.
NIBE VVM 310 5
GOOD TO KNOW ABOUT NIBE™ VVM 310
Dimensions
201780
560
600355
245
615
95
185
215
30-50
80135
190
80135
190300
AA2
AA3-X4
Wilo
Wilo
VVM 310
UB1
UB2
XL4XL30XL2BT3
XL3 XL9
XL18 XL19
XL1 XL8
PF3
BT2
PF1
AA3
AA7
K1
QN10
GP1
QM20
BT63
BT7
EB1
BF1
PF1PF3
FD1
BT30
AA1
AA1-X3
AA1-SF1
AA1-X7
FA1
AA1-X1
QN11
AA4
SF1
AA4-XJ3
AA4-XJ4
UB1
UB2
BT6
BT54
GP12QM1QN35BP5
W130
6 NIBE VVM 310
Indoor module design
GOOD TO KNOW ABOUT NIBE™ VVM 310
Frontsida
701775
560
30-50
600
7575 757560 60
610
25
701775
560
30-50
600
7575 757560 60
610
25
PF3
NIBE VVM 310 7
List of components
GOOD TO KNOW ABOUT NIBE™ VVM 310
Pipe connections
XL1 Connection, heating medium supply G20 int.
XL2 Connection, heating medium return line G20 int.
XL3 Connection, cold water G20 int.
XL4 Connection, hot water G20 int.
XL8 Connection, docking in heating medium G20 int.
XL9 Connection, docking out heating medium G20 int.
XL18 Connection, docking in high temp Ø22 mm
XL19 Connection, docking out high temp Ø22 mm
XL30 Connection, expansion vessel G20 int.
HVAC components
GP1 Circulation pump
GP12 Charge pump
QM1 Drain valve, heating medium
QN11 Mixing valve, addition
QM20 Venting, climate system
QN10 Reversing valve, climate system/water heating, supply line
QN35 Reversing valve, climate system/water heating, return line
Sensors etc.
BP5 Manometer, heating system
BT2 T emperature sensor, heating medium supply*
BT3 Temperature sensor, heating medium return*
BT6 Temperature sensor, hot water, charging
BT7 Temperature sensor, hot water, top
BT30 Thermostat, standby mode
BT54 Temperature sensor, external docking
BT63 Temperature sensor, heating medium supply after immersion heater
Electrical components
AA1 Immersion heater card
AA1-SF1 Dipswitch
AA1-X3 Terminal block, immersion heater
AA1-X7 Terminal block, immersion heater
AA2 Base card
AA3 Input circuit board
AA3-X4 Terminal block, current sensors
AA4 Display unit
AA4-XJ3 USB port
AA4-XJ4 Service socket
AA7 Extra relay circuit board
BF1* Energy meter**
EB1 Immersion heater
FA1 Miniature circuit-breaker
FD1 Temperature limiter
K1 Auxiliary relay, emergency mode.
SF1 Switch
W130 Network cable for NIBE Uplink™
Other information
PF1 Type plate
PF3 Serial number plate
UB1 Cable grommet
UB2 Cable grommet
* Not visible in the image**Only available as accessory EMK 310.Designations in component locations according to standard IEC 81346-1 and 81346-2
8 NIBE VVM 310
INSTALLATION
EP30 Solar kit
AA5 Accessory card
BT53 Temperature sensor, solar panel
CM5 Expansion vessel
EP8 Solar panel
GP30 Pump station SPS 10, SPS20
GP30 Pump station SPS 10, SPS 20
FL4 Safety valve, solar
GP4 Pump, solar
QM43 Shut-off valve
QM44 Shut-off valve
QM45 Shut-off valve
RM3 Non-return valve
RM4 Non-return valve
Other information
CM1 Expansion vessel closed, heating medium
EB1 Immersion heater
FL1 Safety valve, hot water
FL2 Safety valve, heating medium
QM40 Shut-off valve
RM1 Non-return valve
Explanation
CL11 Pool kit
AA5 Accessory card
BT51 Temperature sensor, pool
EP5 Exchanger, pool
GP9 Pool, pump
HQ4 Particle filter
QN19 Reversing valve, pool
EB15 VVM 310
XL1 Connection, heating medium, supply 1
XL2 Connection, heating medium, return 1
XL3 Connection, cold water
XL4 Connection, hot water
XL8 Connection, docking, in heating medium
XL9 Connection, docking, out heating medium
XL13 Connection, solar system, supply
XL14 Connection, solar system, return
XL 39 Connection, accessory, out
EB101 Heat pump
FL10 Safety valve
HQ1 Particle filter
RN10 Trim valve
QM1 Draining valve
QM40 Shut-off valve
QM41 Shut-off valve
EM1 Wood burning stove with back boiler
AA5 Accessory card
BT52 Temperature sensor, boiler
EM1 Wood burning stove with back boiler
GP15 Charge pump, external heat source
EP21 Climate system 2
AA5 Accessory card
BT2 Temperature sensor, heating medium, supply
BT3 Temperature sensor, heating medium, return
GP20 Circulation pump, heating medium, lower shunt
QN11 Mixing valve, addition
-FL2
-CM1
-EB15
-XL8 -XL9
NIBE VVM 310 9
-FL2
-CM1
-EB15
-XL8
-XL9
-RN10-EB101
XL2
XL1-HQ1
-QM1
-QM41
-FL10
-QM40
-EB101
Connection as electric boiler
Connect the pipe for docking in from the heat pump (XL8) to the pipe out to the heat pump (XL9).
Installation alternative
Compatible NIBE air/water heat pumpsCompatible NIBE air/water heat pumps must be equipped with a control card with display that has the software version given in the following list as a minimum. The control card version is displayed in the heat pump's display upon start-up.
Connecting to heat pumpAll outdoor pipes must be thermally insulated with at least 20 mm thick pipe insulation. VVM 310 is not equipped with shut off valves; these must be installed outside the indoor module to facil-itate any future servicing. The charge circuit is supplied with trim valve for basic setting of the charge flow.
Product Software version
F2025/F2300 55
F2030/F2040 all versions
VVM 310 can be connected to extra water heater. See the last page for the list of the accessories that can be used with VVM 310.
-FL2
-CM1
-EB15
-XL18
-XL19
-BT52-EM1-AA25
-EM1
-GP15
-FL2
-CM1
-EB15
-XL1
-XL2
-GP20
-BT3
-BT2
-QN25
-EP21-AA25
-FL2
-CM1
-EB15
-XL1
-XL2
-FL2
-XL4
-XL3
-CM1
-EB15
-FL1
-QM40-RM1
INSTALLATION
10 NIBE VVM 310
Connecting cold and hot water The mixing valve must be installed if the factory setting is changed so that the temperature can exceed 60 °C. If the fac-tory setting is changed, national regulations must be observed. The setting is made in menu 5.1.1.
Connecting the climate system
When connecting to a system with thermostats on all radiators/underfloor heating coils, a relief valve must be fitted, or a thermo-stat must be removed to ensure sufficient flow.
Two or more climate systems
When more than one climate system is to be heated, the follow-ing connection can be used. For this connection accessory ECS 40/ECS 41 is required.
Connection of external heat source
For connection to gas/ electric/ oil boiler the DEH 310 accessory is required.
-FL2
-CM1
-EB15
-RN10-EB101
XL2
XL1-HQ1
-QM1
-QM41
-FL10
-QM40
-EB101
-GP9 -BT51 -HQ4
-EP5
-AA25
-CL11
-CL11-QN19
-CL11-GP12
T PT
-FL2-CM1
-XL18
-XL19
-EB15-EP30
-BT53
-EP8
-EB101
-FL10
-AA5-GP30
-RM4
-GP4 -EP5
-RM3
-GP4
-CM5
-FL4
-OM44
-OM43-OM45
XL1
XL2
-RN10 -QM40
-HQ1 -QM41
-QM1
-FL2
-CM1
-EB15
-XL8
-XL9
-RN10-EB101
XL2
XL1-HQ1
-QM1
-QM41
-FL10
-QM40
-EB101
BF1
-FL2
-CM1
-EB15
-XL8
-XL9
-RN10-EB101
XL2
XL1-HQ1
-QM1
-QM41
-FL10
-QM40
-EB101
EB1
-FL2-CM1
-EB15
-FL1
-QM40-RM1
-GP9
XL3
XL4
NIBE VVM 310 11
INSTALLATION
SunThe SCA 35 accessory is required for connection to solar instal-lation.
PoolCharging of the pool is controlled by the pool sensor. In the case of low pool temperatures, the reversing valve reverses direction and opens towards the pool exchanger. Accessory POOL 310 is required for this connection.
Connecting ELK
For connection of external electrical addition, in one step, in event of a stoppage because of cold outdoor air.
Connecting EMK 310 Connection of energy measurement kit EMK 310 (BF1) to VVM 310.
Connecting hot water circulationTo reduce the risk of bacterial growth in systems with hot water circulation, the temperature of the circulating water should not fall below 50°C. There should not be any non-circulatory hot wa-ter pipes. Adjust the hot water system so that the temperature does not fall below 50 °C at the ends of the system.
LE
K
INSTALLATION
12 NIBE VVM 310
USB service outlet
VVM 310 is equipped with a USB socket in the display unit. This USB socket can be used to connect a USB memory stick to up-date the software, save logged information and handle the set-tings in VVM 310.
SMS 40
VVM 310 can be controlled and monitored externally with ac-cessory SMS 40. SMS 40 consists of a communications module, a GSM modem with an antenna and a separate power supply unit with jack for plugging into a wall socket. The antenna can be placed outside the enclosure. SMS 40 enables operation to be controlled and monitored, via a GSM module, using a mo-bile phone via SMS messages. For the GSM function to work, the communications module must be equipped with a valid GSM subscription. This may, for example, be a pay as you go card or a special telematics subscription. For further presentation, visit www.nibe.eu
NIBE UplinkTM
Using the Internet and NIBE UplinkTM you can get a quick over-view and the present status of the installation the heating in your home. You get a good overall view where you can follow and control the heating and hot water comfort. If your system is af-fected by an operational disturbance, you receive an alert via e-mail that allows you to react quickly. NIBE UplinkTM also gives you the opportunity to easily control the comfort in the home, no matter where you are.
Range of services
Via NIBE UplinkTM you have access to different levels of service. A basic level that is free and a premium level where you can select different extended service functions for a fixed annual subscrip-tion fee (the subscription fee varies depending on the selected functions).
Installation and associated equipment requirements
The following is required in order for NIBE UplinkTM to work with the installation:
• Network cable Cat.5e UTP (straight, male-male), wired net-work communication.
• Internet connection (broadband).
• The web browser that supports JavaScript. If Internet Explor-er is used, it must be version 7 or higher. See the help file in the web browser for information about how to activate JavaScript.
Electrical connectionsGeneral
All electrical equipment, except the outdoor sensors, room sen-sors and the current sensors are already connected at the factory.
• Disconnect the indoor module before insulation testing the house wiring.
• When the building is equipped with an earth-fault breaker, VVM 310 should be equipped with a separate one.
• The electrical circuit diagram for the indoor module is at the end of this Installer manual.
• Communication and sensor cables to external connections must not be laid close to high current cables.
• The minimum area of communication and sensor cables to ex-ternal connections must be 0.5 mm² up to 50m, for example EKKX, LiYY or equivalent.
• When cable routing in VVM 310 cable grommets UB1 and UB2 must be used. In UB1 and UB2 the cables are inserted through the indoor module from the back to the front.
Miniature circuit-breaker
The indoor module and a large proportion of its internal com-ponents are internally fused by a miniature circuit breaker (FA1).
Temperature limiter
The temperature limiter (FD1) cuts the current supply to the elec-trical addition if the temperature rises to between 90 and 100 °C and is manually reset.
SettingsElectrical addition - maximum output
The immersion heater can be set up to a maximum of 12 kW. Delivery setting is 8 kW. The immersion heater output is divided into 9 steps, according to the table in the Installer manual. Set-ting maximum output in the electrical addition is done in menu 5.1.12.
Standby mode
When the indoor module switch (SF1) is set to emergency mode only the most necessary functions are activated.
• The hot water capacity is reduced.
• The load monitor is not connected.
• Fixed temperature in the supply line.
6
4
8
10
12
14
16
18
20
50 100 150 200 250 300 350 400 450
Tappflöde (liter/minut)
Volym varmvatten (liter)
Varmvattenkapacitet VVM310
Ekonomi
Ekonomi
Normal
Normal
Lyx
Lyx
The diagram above displays what hot water capacity VVM 310 can supply at the different selectable comfort modes.
The difference between the selectable modes is the temperature of the hot tap water. Higher temperature means hot water lasts longer.
economy: This position gives less hot water, but is more eco-nomical. This mode can be used in smaller households with a small hot water requirement.
Water capacityHot water capacity NIBE VVM 310 with NIBE F2040/F2300
Tap flow (l/min)
Economy Normal Lux
Tap volume (l) hot water
normal: Normal mode gives a larger amount of hot water and is suitable for most households.
luxury: Lux mode gives the greatest possible amount of hot wa-ter. In this mode, the immersion heater, as well as the compressor, is used to heat hot water, which may increase operating costs.
F2040 requires additional heat (internal or external) to reach Lux-ury.
In most cases, F2300 reaches all three settings (including Lux), with just a compressor.
Pump capacity diagramAvailable pressure, circulation pump for heating systems, GP1 Available pressure, charge circulation pump, GP12
Available pressure (Pa)
Water flow (l/s)Water flow (l/s)
INSTALLATION
0
10
20
30
40
50
60
0 200 400 600 800 1000 1200 1400 1600 1800 2000Flöde (liter/timme)
Tillgängligt tryck [kPa]
Tillgängligt tryck cirkulationspump, GP1
0
10
20
30
40
50
60
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Tillgängligt tryck cirkulationspump, GP12
Flöde (liter/timme)
Tillgängligt tryck [kPa]
Available pressure (Pa)
NIBE VVM 310 13
14 NIBE VVM 310
THE DISPLAY
Display unit
Display, A
Instructions, settings and operational information are shown on the display. The easy-to-read display and menu system facilitates navigation between the different menus and options to set the comfort or obtain the information you require.
Status lamp, B
The status lamp indicates the status of the heat pump. It:
• lightsgreenduringnormaloperation.
• lightsyellowinemergencymode.
• lightsredintheeventofadeployedalarm.
OK button, C
The OK button is used to:
• confirmselectionsofsubmenus/options/setvalues/pageinthestartguide.
Back button, D
The back button is used to:
• gobacktothepreviousmenu.
• changeasettingthathasnotbeenconfirmed.
B
A
C
D
E
FVVM 310
Status lamp
Display
OK button
Back button
Control knob
Switch
Control knob, E
The control knob can be turned to the right or left. You can:
• scrollinmenusandbetweenoptions.
• increaseanddecreasethevalues.
• changepageinmultiplepageinstructions(forexamplehelptextandserviceinfo).
Switch, F
The switch assumes three positions:
• On( )
• Standby( )
• Emergencymode( )
A large, easy to read multicoulour display gives everyone the chance to maximize the energy saving potential of this exciting green technology!
HEAT PUMP
NIBE UplinkTM
(if contact with NIBE
UplinkTM is available)
INDOOR CLIMATE HOT WATER
NIBE VVM 310 15
THE DISPLAY
Menu system When the door to the heat pump is opened, the menu system’s four main menus are shown in the display as well as certain ba-sic information.
Menu 1 – Indoor climate
Setting and scheduling the indoor climate.
Menu 2 – Hot water
Setting and scheduling hot water production.
This menu only appears if a water heater is docked to the heat pump.
Menu 3 - Info
Display of temperature and other operating information and ac-cess to the alarm log.
Menu 4 – Heat pump
Setting time, date, language, display, operating mode etc.
Menu 5 - Service
Advanced settings. These settings are not available to the user. The menu is visible by pressing the Back button for 7 seconds.
Start guideThe first time the heat pump is started a start guide is started. The start guide instructions state what needs to carried out at the first start together with a run through of the heat pump’s basic settings.
The start guide ensures that the start-up is carried out correctly and cannot be bypassed. The start guide can be started later in menu 5.7.
Indoor temperature - (if a room sensor is connected)Outdoor temp. Hot water temp.
Extra hot water (if activated)
Estimated amount of hot water
If the start guide is left on this page it closes automatically in 60 min
16 NIBE VVM 310
1) Applies to outdoor air heat pump at 7/45 °C (outdoor temperature / Supply temperature)
IP 21TECHNICAL SPECIFICATIONS
3x400V
Maxim heat pump output NIBE F2025 with program version 55 or later 1) kW 10
Maxim heat pump output NIBE F2026 with program version 55 or later 1) kW 10
Maximum heat pump output NIBE F2030 1) kW 9
Maximum heat pump output NIBE F2040 1) kW 12
Maximum additional power (internal) kW 12
Electrical data
Rated voltage 400V 3NAC 50 Hz
Max operating current A 19,4
Fuse A 20
Power, HM pump W 10 - 110
Output charge pump W 10 - 110
IP class IP 21
Heating medium circuit
Energy class circ-pump low energy
Energy class charge pump low energy
Max system pressure heating medium MPa 0.3 (3 bar)
Min flow l/t 500
Max HM temp °C 70
Pipe connections
Heating medium, CU pipe G20 int.
Hot water connection G20 int.
Cold water connection G20 int.
Heat pump connections G20 int.
Connection for expansion vessel G20 int.
Other information
Indoor module
Volume coil litre 17
Volume, total indoor module litre 270
Volume buffer vessel litre 50
Cut-off pressure, coil MPa 1.0 (10 bar)
Max permitted pressure in indoor module MPa 0.3 (3 bar)
Capacity hot water heating According to EN 255-3
Tap volume 40°C at Eco comfort litre See diagram page 13.
Tap volume 40°C at Normal comfort litre See diagram page 13.
Tap volume 40°C at Luxury comfort litre See diagram page 13.
Dimensions and weight
Width mm 600
Depth mm 615
Height (without base) mm 1800
Height (with base) mm 1830 – 1850
Required ceiling height mm 1910
Weight (excl. packaging and without water) kg 140
LEK
LEK
LEK
LEK
LEK
LEK
LEK
LEK
LEK
LE
K
LEK
LEK
LEK
LEK
LEK
LEK
LEK
LEK
LEK
LEK
NIBE VVM 310 17
ACCESSORIES
Active cooling ACS 310
Part no. 067 248
Energy measurement kit EMK 310
This accessory is used to measure the amount of en-ergy VVM 310 produces and supplies for hot water and
heating in the building.
Part no. 067 246
External electrical addi-tion ELK
This accessory requires ac-cessory DEH 310
(step controlled addition-al heat).
ELK 15
Part no. 069 022
Extra shunt group ECS 40/ECS 41
This accessory is used when VVM 310 is installed in
houses with two or more different climate systems that require different sup-
ply temperatures.
ECS 40 (max 80 m2)
Part no. 067 287 ECS 41 (min 80 m2)
Part no. 067 288
Base extension EF 45
Part no. 067 152
Auxiliary relay HR 10
Part no 089 423
Control unit for external heat source
DEH 310 (oil/electric-ity/gas)
Part no. 067 249
Pool heating POOL 310
POOL 310 is an accessory that enables pool heating
with VVM 310. Part no. 067 247
Communication module SMS 40
SMS 40 enables VVM 310 to be controlled and moni-tored via SMS messages. The mobile application ”NIBE Mobile App” can
be used with a mobile tel-ephone with the Android
operating system.
Part no. 067 073
Communication module MODBUS 40
MODBUS 40 enables VVM 310 to be controlled and
monitored using a DUC in buildings. Communication takes place using a MOD-
BUS-RTU.
Part no. 067 144
Room unit RMU 40
RMU 40 means that con-trol and monitoring of the indoor module can be car-ried out in a different part of the accommodation to
where VVM 310 is located.
Part no. 067 064
Top cabinet
2050mm
Part no. 089 756
2150 mm
Part no. 089 757
2200-2450 mm
Part no. 089 758
Heat pump F2040
8 kW Part no. 064 109
12 kW Part no. 064 092
16 kW Part no. 064 108
Heat pump F2030
7 kW Part no. 064 099
9 kW Part no. 064 070
SCA 35 (solar)
Possible connection and control of solar heating.
Part no. 067 245
For complete solar pack-age, see www.nibe.eu
18 NIBE VVM 310
This brochure is a publication from NIBE. All product illustrations, facts and specifications are based on current information at the time of the publication’s approval. NIBE makes reservations for any factual or printing errors in this brochure. Photos: www.benfoto.se. ©NIBE 2014.
NIBE is ISO-certified: SS-EN ISO 9001:2000SS-EN ISO 14001:2004
6395
84 T
echn
ical
PBD
GB
NIB
E V
VM
310
143
3-1
NIBE Energy Systems ABBox 14285 21 MarkarydSWEDENTel. +46 433 - 73 000www.nibe.eu
top related