news in visualisation - rotec.bg seminar 2016 ppt/2016_rotec...news in visualisation peter kacz, ......
Post on 15-Mar-2018
217 Views
Preview:
TRANSCRIPT
PUBLIC
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 1
News in visualisation
Peter Kacz, Commercial Engineer
Rotec Seminar 2016, Borovets Hills
23th-25th November 2016
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 2PUBLIC
SCALABLE • HIGH RESOLUTION • WIDE-SCREEN FORMATS
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 3PUBLIC
Sleek, Modern Design
Improved Performance
Enhanced Logix Integration
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
6.5”, 9”W, 10.4”, 12”W, 15”, 19”
Low profile aluminum bezel
TFT color displays with LED backlight
Resistive touch screen with navigation button
and keypad options
Device level ring (DLR) Ethernet
DC and AC power options
MODERN DESIGN
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
Durable powder-coated aluminum bezel
Robust and reliable resistive touchscreen
Full overlay design
Provides additional protection to prevent
damage to the touchscreen
Environmental Ratings - 055 C, 15g shock, 2g peak
vibration, NEMA Type 4X (indoor), IP66, Class 1 Div 2
MODERN DESIGN
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
Isolated DC power supply
Users can power all their equipment from one large DC power source
No need for separate UL Class 2 or SELV/PELV power source
Eliminates ground loop issues and high current grounding issues
Highly Accelerated Life Testing (HALT)
A stress test methodology used to find weak points in
design and development
Used by military, airlines, and industrial applications
MODERN DESIGN
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H7
EASY NAVIGATION
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H8
INTUITIVE OPERATION
Default System Banner
• Notifications
• Alarms
• Screen navigation
• Active User
• Date/Time
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H9
ADVANCED DIAGNOSTICS
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
View Designer
10
Scalable vector graphics
Intuitive design environment
Optimized Logix integration
TM
®
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
Project Explorer contains the structure
of the project
Properties Pane helps configure
elements
Searchable Toolbox of pre-built elements
Canvas area used for creating screens
VIEW DESIGNERGraphic Explorer displays graphic
elements
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
10”
19”
+1000MORE
SCALABLE GRAPHICS
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H13
Comprehensive library of graphics in View Designer: shapes, common controls, equipment, ISO and ISA symbols
Embedded animation and behavior: color and movement animation and control actions built into many objects
SVGs allow reusable screen content - automatically scale screen content as appropriate for the target terminal
Graphical objects are linked to controller objects
Typ
ical
HM
IP
anel
Vie
w
5500
ENHANCED GRAPHICS
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
Logix Designer View Designer
• Tag Definitions
(including extended
properties)
• Alarm Settings
• Data Types
Studio 5000 View Designer
New Tag Browser
Interface Saves development by eliminating redundant entry
View Designer browses controller tags separately
User-defined, HMI graphic objects can be built and mapped to logical objects
EXTENDED TAG PROPERTIES
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H 15
LOGIX BASED ALARMS
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
HMI Button Control
HMIBC HMIButtonJog …
HMIBC
HMI Button Control
HMIBC HMIButtonJog …
HMIBC
16
HIGH-SPEED BUTTON CONTROL
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.PUBLIC - 5058-CO900H
Integrated approach to next generation operator interface
using the new Studio 5000 View Designer software
Modern Design - Intuitive, sleek design with wide screen
options and enhanced graphics
Improved Performance:
Pre-configured system banner provides diagnostic indicators
Scalable vector graphics to adjust screens to any terminal size
Enhanced Logix Integration:
Logix-based alarms are automatically available in terminal
High-speed HMI buttons provide quick feedback for jogging applications
OVERVIEW SUMMARY
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 18PUBLIC
PanelView Portfolio
PanelView ClassicPanelView Standard
PanelView Enhanced
PanelView Plus
PanelView Plus
Compact
PanelView Plus 6
…
PanelView family from 1989
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 19PUBLIC
PanelView Portfolio
PanelView ClassicPanelView Standard
PanelView Enhanced
PanelView Plus
PanelView Plus
Compact
PanelView Plus 6
…
PanelView Plus 7 extends the Portfolio further
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 20PUBLIC
PanelView Plus 7Standard and Performance Models
New Displays
Increased screen resolution
Wide screen options
Additional sizes – from 4” to 19”
Certifications:
ATEX on all Standard models and future on Performance models
IP66, IP54, NEMA 12, NEMA 13 and NEMA 4X
More Screen Options …..Greater Resolutions …..
Additional Certifications …..
Standard and Performance models
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 21PUBLIC
PanelView Plus 7 StandardFeatures & Benefits
Standard
4.3”W, 5.7”, 6.5”, 9”W, 10.4”, 12”W, 15”
Low profile composite bezel
Resistive touch screen
Single or DLR Ethernet ports
ARM processor
512 MB Flash Memory / 512 MB RAM
Windows CE 6.0 standard features
DC powered
Removable Battery
Targeted for simpler / smaller applications
ATEX Certification, Class 1 Div. 2
Machine Builder Focused
OEM Optimized Design
Expanded Processing Power
Composite bezel
Competitive Solution
More screen options
Greater resolution
Wide screen options
Application Size Limits
1 Controller
≤25 Screens
≤200 Alarms
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 22PUBLIC
PanelView Plus 7 PerformanceFor Demanding Industries
Performance
6.5”, 9”W, 10.4”, 12”W, 19”
Low profile painted aluminum bezel
Resistive touch screen with keypad options
DLR Ethernet ports
X86 processor
512 MB Flash Memory / 512 MB RAM
Windows CE 6.0 extended features
DC and AC power options
Targeted at larger / complex applications
ATEX Certification (Future release)
Larger Applications
Robust Design
Expanded Processing Power
Larger Applications
Examples:
≤300 Screens
≤3,000 Tags
≤400 Alarms
Ideal for Variety of Industries
Process
Metals
Mining / Aggregate
Tire and Rubber
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 23PUBLIC
PanelView Plus 7 Comparison of Features
Product FeaturesPanelView Plus 7
Standard model
PanelView Plus 7
Performance model
FactoryTalk Machine Edition Y Y
ViewPoint Y Y
Memory RAM / Flash 512 MB / 512 MB 512 MB / 512 MB
PDF Viewer Y Y
Active X Controls (Email, DataStorePlus, Recipe) Y Y
Remote Terminal Control (Based on VNC) Y Y
FTP Server Y Y
MPEG Video playback N Y
Microsoft Office Viewers N Y
Microsoft Internet Explorer N Y
Remote Desktop Services N Y
Ethernet Connectivity Y (Single or DLR) Y (DLR)
CPU ARM 1Ghz x86 1.6Ghz
Screen Sizes 4.3”-15” 6.5”, 9”W, 10.4”, 12”W, 19”
Application Sizes 1 Controller, 25 Screens, 200 Alarms Larger Applications
Catalog numbers 2711P-xxxxx8S 2711P-xxxxx9P
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 24PUBLIC
PanelView Plus 7 Standard
Learn about the features and benefits of the terminals
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 25PUBLIC
PanelView Plus 7 Standard
Decrease time to market…Increased screen resolution…
Standard Model – Single Ethernet
Machine Builder Focus
Sizes: 4”-15”
Single or Dual Ethernet (DLR)
Touch Screen
Low Profile, Composite Bezel
FactoryTalk View Machine Edition - supporting MER files back to 5.1
14 Catalogs – Allen-Bradley Branded
14 Catalogs – No Branding
Widescreens …..
New Display Sizes…..
ATEX Certifications …..
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 26PUBLIC
PanelView Plus 7 Standard Anatomy
SD storage card slot for data storage and terminal replication
USB Ports for quick upload and download to the terminal
New installation clamps provide fast and simple terminal installation and removal
Embedded Ethernet port for connectivity from the machine to the enterprise
Easy access battery cover
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 27PUBLIC
SD Card Data Storage
Quick and Easy Terminal Copy & Restore
Use an SD card to quickly create copies of a terminal to
reduce your time to market or restore a terminal.
• Operating system
• Network configuration and terminal settings
• FactoryTalk View Machine Edition (ME) runtime file
• Data logs and recipe files
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 28PUBLIC
PanelView Plus 7Ethernet Connectivity
Embedded DLR using Standard or
Performance terminals example
Available communication options:
• Ethernet Only
• Standard 4”-15” Single or DLR
Ethernet Port
• Performance 7”-19” DLR
Ethernet port
Single Ethernet port in Standard terminal example
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 29PUBLIC
PanelView Plus 6 Compact vs.
PanelView Plus 7 Standard Display Sizes
4.3 in. wide
(480x272)5.7 in.
(640x480)
6.5 in.
(640x480)
9.0 in. wide
(800x480)
12.1 in. wide
(1280x800)
10.4 in.
(800x600)
15.0 in.
(1024x768)
3.5 in.
(320x240)
5.7 in.
(320x240)
10.4 in.
(640x480)
More Screens Sizes and Greater Resolution to Choose From
PanelView Plus 6
Compact
PanelView Plus 7
Standard
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 30PUBLIC
PanelView Plus 7 Performance
Learn about the features and benefits of the terminals
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 31PUBLIC
PanelView Plus 7 Performance
31
Machine builder and end user focus
Sizes: 6.5”, 9”W, 10.4”, 12”W, 19”
Dual Ethernet DLR connectivity
Touch Screen or keypad options
Available in AC or DC
No limitations
FactoryTalk View Machine Edition v8
14 Catalogs – Allen-Bradley Branded
14 Catalogs – No BrandingWidescreens …..
New Display Sizes…..Dual Ethernet DLR
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 32PUBLIC
PanelView Plus 7 Performance
32
Mobile ready with VNC support and FactoryTalkViewpoint
With the embedded PDF Viewer, show: • User Manuals • Installation Manuals • SOPs (Standard Operating Procedures)
Faceplates and Add-on Instructions can save 50 – 90% of complex screen development time
Widescreen, keypad and touchscreen options
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 33PUBLIC
PanelView Plus 7 Performance
33
SD storage card slot for data storage and terminal replication
USB Ports for quick upload and download to the terminal
New installation clamps provide fast and simple terminal installation and removal
Embedded dual Ethernet port with DLR connectivity
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 34PUBLIC
PanelView Plus 7Productivity Tools
34
Use Datastore Plus to log data to identify and adjust process variation; View and
Analyze in Microsoft Excel
Configure email notifications for critical equipment alarms
RDP client feature helps make the PanelView Plus 7 into a thin client terminal
Web browser ActiveX to embed HTML pages inside the HMI application
Video playback support provides advanced “user help” capability
Load maintenance manuals directly on terminal
Bookmark important pages and tie them to critical alarms
Identify and fix fault codes quickly
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 35PUBLIC
35
FactoryTalk ViewPoint - Extend visualization and real-time decision capabilities to browser-based
remote users:
• On-demand web access from anywhere
• Supports multiple browsers / client devices
Virtual Network Computing (VNC) - Extends graphical
desktop sharing of a PanelView Plus 7 terminals and
its content to remote users
File Transfer Protocol (FTP) - allows transferring of files
to/from your PC to PanelView Plus 7 terminals, including
alarm logs, data logs, CSV Recipe Files, PDF manuals
and videos
PanelView Plus 7Mobility Tools
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 36PUBLIC
PanelView Plus 6 vs PanelView Plus 7Performance Display Sizes
19.0 in.
(1280x1024)6.5 in.
(640x480)
9.0 in.
wide
(800x480)
12.1 in. wide
(1280x800)
10.4 in.
(800x600)
15.0 in.
(1024x768)
3.5 in.
(320x240)
5.7 in.
(320x240)
10.4 in.
(640x480)6.5 in.
(640x480)
12.1 in.
(800x600)
15 in.
(1024x768)
PanelView Plus 6 to PanelView Plus 7 adapter plates will be available for Performance lines only
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 37PUBLIC
Summary
PanelView Plus 7 Portfolio:
Extends our portfolio with more display sizes and certifications
Reflects our commitment to application longevity
Same FactoryTalk View software across all PanelView Plus product lines
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 38PUBLIC
MobileView Tethered Operator Terminal
The MobileView Tethered Operator Terminal expands the visualization portfolio by taking the
terminal mobile and improves productivity by eliminating the need for two operators for certain
operations. With three cable length options and a hardwired E-STOP and 3-position enabling
switches, the terminal helps contribute to a safe production environment.
38
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 39PUBLIC
MobileView Tethered Benefits
Increase operator productivity • Reduce time by having the operator terminal within line of sight of process
• 5M, 10M or 15M cable with “quick connect” connector and mounting bracket options
• Optional software assignable function keys with either hardwired momentary push button
or key switch
Innovative Design• 10” wide display (1280x800) with resistive touch screen for easy viewing
• Windows Embedded Standard 7 operating system optimized for FactoryTalk View ME
Establish a safer environment• Hardwired E-STOP and 3-Position enabling switches for additional safety
• IP65, 0-45C operating temperature and 1M drop rated to work in industrial environments
39
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 40PUBLIC
MobileView Tethered Differentiators
5m, 10m, 15m cable with
“quick connect” connector
Optional software
assignable function
keys
10” wide screen
(1280x800)
Optional pushbutton
or key switch3 position enabling
switch
Hardwired
E-stopUSB port
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 41PUBLIC
Out-of-box experience similar to a computer
Quick-start guide and detailed user manual available
FactoryTalk View ME updates delivered via new system image
Built in backup and restore tool for deploying updated system
image
System images will be posted to Product Compatibility &
Download Center
Initial release with FactoryTalk View ME 8.0 system image
41
MobileView Configuration
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 42PUBLIC
Configuration and Application Building
FactoryTalk View Machine Edition 8.0 Feature Information
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 43PUBLIC
Simplified Project Maintenance
4
• Improved handling of multiple FactoryTalk View Machine Edition applications on same PC
• Each project has its own private security configuration
• Users, Groups, and policy
Overview
• Allows user to restore a project (MER/APA) without overwriting any other project’s security configuration
• No need to be ‘careful’ when restoring MER or APA
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 44PUBLIC
44
Resizable Alarm Editor
• Alarm Editor allows resizing of the various tables in the dialog
Overview
• Easier to manage and configure Alarms
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 45PUBLIC
Application Manager Workflow
4
• Application Manager returns to starting step when an operation completes
• Application Manager allows user to overwrite existing
• backup (APA) files when creating a backup file
• project when restoring a backup (APA) or runtime (MER) file
Overview
• Allows user to immediately initiate next operation saving time
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 46PUBLIC
Improved Run-Time Experience
FactoryTalk View Machine Edition 8.0 Feature Information
4
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 47PUBLIC
47
Run-time User ManagementVME
• New objects to manage native FactoryTalk and Windows-linked users
• Add, Delete, Change Group, Enable, Disable, Unlock, Change Account Properties, Change Password
• Add, remove, and modify user accounts while an MER is running
• Security configuration changes persisted in the MER
Overview
• No longer need to rebuild MER to change security configuration
• Support for 21 CFR Part 11 compliance
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 48PUBLIC
48
Administrative Change Password
• Change Password button modified to add an Administrative mode, that allows user’s with access to change ANY user password
• Security configuration changes persisted in the MER
Overview
• Prevents users being ‘locked’ out of system by a malicious actor
• More administrative control of user account passwords
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 49PUBLIC
Windows 2008 and 2012 Server Active Directory Authentication Support
4
• Added LDAP and LDAP over SSL to the PanelView Plus terminals
• Existing application will work in Windows 2008/2012 domains, unchanged
• LDAP configuration applies to the terminal, not the application
• Operation transparent to Operator/User
Overview
• Windows-linked user and groups support centralized account management
• Support for 21 CFR Part 11 compliance
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 50PUBLIC
50
Login Button Improvements Support Domain Integration
• Enhanced login button supports
• Control of domain field visibility
• Allow/ Disallow domain field editing
• Domain field content can be fixed, user entered, or bound to a tag
• Obscure user name entry with ‘#’
Overview
• Saves operator time
• Requires less Operator knowledge
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 51PUBLIC
Changes to A-P Security Codes
5
Assume a user is a member of more than one group. The groups have the following configured security codes
At run-time the user’s effectivesecurity codes have changed in v8.0 and later, compared to earlier versions
Runtime Security Configuration A B C D
Group1 X X X
Group2 X X X
Effective A-P Security Codes A B C D
FactoryTalk View v8.0 X X
FactoryTalk View v7.0, and earlier X X X X
• All of a user’s A-P configurations are ANDedtogether in v8.0, and later
• If a user is a member of more than one A-P configuration, at run-time the user’s effectiveA-P Security Code permissions will be the most restricted set
• previous versions granted the most lenient effective Security Code A-P permissions
Overview
• Support for 21 CFR Part 11 compliance
Benefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 52PUBLIC
Capture Value Before ChangeVME
VSE
FactoryTalk AssetCentre
Audit Log View
Audit Message Detail
• When you change the numeric or string input value, the previous value is logged and shown in the FactoryTalk AssetCentre Audit Log
Overview
• Provides improved tracking of operator actions
• Improves support for 21 CFR Part 11 compliance
• Streamlines troubleshooting process
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 53PUBLIC
New User Group Security Function
5
• CurrentUserHasGroup() –Returns True/False whether the current user is assigned to the specified FactoryTalk user group
• Example usageCurrentUserHasGroup(“Engineers”)
Overview
• Enables evaluation of a user’s membership in a security group from a display screen
Benefits
CurrentUserHasGroup() security
function
VME
VSE
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 54PUBLIC
Improved System Error-proofing
5
• When building MER system warns if a shortcut uses an unsupported network, Ex. RIO
• When loading MER on PanelView Plus terminal will warn if
• MER project resolution (size or aspect ratio) does not match physical terminal
• MER shortcut(s) references a network the terminal cannot support,Ex. PanelView Plus 7 and DH+
Overview
• Saves wasted timeBenefits
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 55PUBLIC
RSLinx Enterprise AcceptsUnsolicited Messages
5
• Controllers send Direct Tag information to HMI application under programmatic control
• Control program determines when information is transmitted to HMI
Overview
• Unsolicited messages can be used to reduce network traffic for ‘exception’ events (Ex. Alarms)
• Normal tag data is polled, or solicited, from the controller
Benefits
VME
VSE
HMI Display
FTLive Data(RSLinx Enterprise)
Controller(CLX, PLC5, SLC500)
Polling
Polling
HMI Display
FTLive Data(RSLinx Enterprise)
Controller(CLX, PLC5, SLC500)
Polling
UnsolicitedMessage
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 56PUBLIC
Expanded Operating System Support
FactoryTalk View Machine Edition 8.0 Feature Information
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 57PUBLIC
Expanded Operating System Support
5
Windows 8, Windows 8.1 Update and Windows 2012 Server R2
join the list of supported operating systems in this release.
VME
VSE
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 59PUBLIC
Removing Operating System Support
5
FactoryTalk View v8.0 is the LAST release to support
Windows XP [any edition or SP]
Windows Vista [any edition or SP]
Windows 2003 Server [any edition or SP]
VME
VSE
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 60PUBLIC
Removing PanelView PlusPlatform Support
6
FactoryTalk View 8.0 is the LAST release to support v 3.2 and v4.0 MER
Using release after v8.0, it is not possible to create v3.2 or v4.0 MER
Using release after v8.0, it is not possible to execute v3.2 or v4.0 MER
Using release after v8.0, it IS possible to open and convert legacy
applications the newer project format
VME
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 61PUBLIC
FactoryTalk® View Machine Edition v8.20Overview
• Control group visibility from Object Explorer
• Switch design-time HMI application language
• Other usability enhancements
Design-time Improvements
• PanelView™ Plus 7 Standard with Device Level Ring (DLR)
• Multi-pen XY Chart ActiveX
• Improved control over system response to operator inactivity
Run-time Enhancements
• Intrinsic electronic signature function
• Detect data falsification in CSV data log
Regulated Environments
• Dropped Windows XP supportPlatform Support
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 62PUBLIC
Design-time Improvements
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 63PUBLIC
Control Group Visibility at Design Time
• Control what objects or groups are visible while editing a display
• Emulates ‘layers’ in graphic editors
• Does not effect run-time visibility
Overview
• Simplify maintenance of complicated displays with overlapping or stacked objects and groups
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 64PUBLIC
Design Time Language Switching
• Change the HMI application language locale at design-time
• Text changes are persisted in current language locale
Overview
• Eliminates need to close and re-open the HMI application
• No need to export strings
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 65PUBLIC
Design Time Usability Enhancements
New HMI project display resolution matches user-selected terminal size,
eliminating need to scale application immediately after creation
Allow resize of sub-editor windows and table columns to improve
readability and easier editing
Macro editor
Information Message editor
Local Message editor
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 66PUBLIC
Runtime Enhancements
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 67PUBLIC
Support PanelView™ Plus 7 Standard w/ Device Level Ring
• Expands PanelView™ Plus 7 Standard so that each terminal includes either an embedded Ethernet Port or a switch (DLR)
• All PanelView™ Plus 7 Performance terminals come with an embedded switch (DLR)
Overview
• Reduce system cost by eliminating a switch
• Improved Ethernet diagnostics
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 68PUBLIC
XY Chart ActiveX Control
• Chart 8 pens against one set of axis values
• Supports a maximum of 500 data points / pen
• Like a Logix AOI the ActiveX uses a pre-defined UDT in the controller application to persist and retrieve tag data for the chart
Overview
• Meet application needs that are not possible with current trend control
• Visually compare multiple data sets non-times-series data points
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 69PUBLIC
Improved Control of System Response
• Individual setpoint for automatic logout and automatic display navigation
• Control program can inhibit inactivity timeout
• Remaining time before inactivity action executes can be written to a tag
Overview
• Allow operator that was busy to re-authenticate before system automatically navigates to a ‘home’ display
• Allow maintenance to be performed without the operator inactivity action interrupting the maintenance task
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 70PUBLIC
Support for Regulated Environments
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 71PUBLIC
Electronic Signature
• Controls that write data can be configured to required an electronic signature
• Three modes: Comment, Operator signed, Counter-signed
• Generates audit to FactoryTalk® AssetCentreserver
Overview
• Control access to critical process setpoints and values
• Track operator actions
• Enables application validation to FDA 21CFR Part11 regulation
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 72PUBLIC
Detect Falsification in CSV Data Log
• ActiveX control data logging adds data integrity information with each row in CSV file
• Desktop utility can detect unauthorized changes in CSV data log file
• Faster logging rates 250ms and 500ms
Overview
• Ensure that CSV data log can be used to record critical process variables
• Include tamper-detection utility in 21CFR Part11 validation strategies
• Improve accuracy of data log
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 73PUBLIC
Platform Support
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 74PUBLIC
OS Platform Support
Supported Windows Server 2012 Std (64 bit)
Windows Server 2012 R2 Std (64 bit)
Windows Server 2008 R2 Enterprise Edition
Windows 7 SP 1 Enterprise Edition
Windows 7 SP 1 Ultimate Edition
Windows 8.10 Pro (32 / 64 bit)
Windows 8.10 Enterprise (32 / 64 bit)
Windows 8 Pro (32 / 64 bit)
Windows 8 Enterprise (32 / 64 bit)
No Longer Supported
(Last version supporting) Windows XP (8.10)
Windows Vista (8.00)
Windows Server 2003 (8.00)
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 75PUBLIC
Summary of Release CPR 9 SR8
Products and Services Released:
FactoryTalk® View Site Edition 8.20
FactoryTalk® View Machine Edition 8.20
FactoryTalk® ViewPoint 8.20
FactoryTalk® Services Platform 2.80
FactoryTalk® Alarms and Events 2.80
RSLinx® Enterprise 5.80
RSLinx® Classic 3.80
FactoryTalk® Activation 3.62.01
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 76PUBLIC
For more Information
http://www.rockwellautomation.com/rockwellsoftware/products/factorytalk-view-me.page
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 77PUBLIC
Overview
• Control group visibility from Object Explorer
• Switch HMI application language in FactoryTalk View Studio
Design Time Improvements
• TrendX Enhancements
• Custom Caption on Keypad - Numeric and String
Run Time
Improvements
• Support for FactoryTalk® View 8.20Mobility Updates
• Same as v8.10 Release for OS supportPlatform Support
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 78PUBLIC
Design Time Improvements
FactoryTalk® View Studio Enhancements
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 79PUBLIC
Control Group Visibility at Design Time
• Control what objects or groups are visible while editing a display.
• Emulates ‘layers’ in graphic editors.
• Does not effect run-time visibility.
Overview
• Simplify maintenance of complicated displays with overlapping or stacked objects and groups.
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 80PUBLIC
Design Time Language Switching
• Change the HMI application language locale at design-time.
• Text changes are persisted in current language locale.
Overview
• Eliminates need to close and re-open the HMI application.
• No need to export strings.
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 81PUBLIC
Run Time Improvements
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 82PUBLIC
Logarithmic Trending
• Always see pens on a logarithmic scale.
Overview
• Clearly see the relative change of small values on the trend that would otherwise not be seen.
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 83PUBLIC
Export Trend Data
• Export trend or data log data to a CSV file.
• Supports trend data or data points directly from HMI datalogs or Historian.
Overview
• Easily save data for analyzing later without using an external tool.
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 84PUBLIC
Custom Caption on Keypad
• Add a user-defined caption to the numeric and string entry keypad.
• Supports user-defined captions, including embedded tags and values, multi-language.
Overview
• Provides a richer operator experience beyond tag name and tag description.
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 85PUBLIC
Mobility Support
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 86PUBLIC
FactoryTalk® ViewPoint
• Support release including support for FactoryTalk® View 8.20 and all cumulative improvements.
Overview
• Unique mobile experience for existing HMI content with little or no additional development.
Benefits
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 87PUBLIC
Platform Support
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 88PUBLIC
Operating System Platform Support
OS Support:
Windows Server 2012 Std (64 bit)
Windows Server 2012 R2 Std (64 bit)
Windows Server 2008 R2 Enterprise
Edition
Windows 7 SP 1 Enterprise Edition
Windows 7 SP 1 Ultimate Edition
Windows 8.10 Pro (32 / 64 bit)
Windows 8.10 Enterprise (32 / 64 bit)
Windows 8 Pro (32 / 64 bit)
Windows 8 Enterprise (32 / 64 bit)
* Last version supporting
OS No Longer Supported*:
Windows XP (8.10)
Windows Vista (8.00)
Windows Server 2003 (8.00)
Planned for v9.0, October 2016
Windows 10
Windows Server 2016
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 89PUBLIC
Summary of Release CPR 9 SR8
Products and Services Released:
FactoryTalk® View Site Edition 8.20
FactoryTalk® View Machine Edition 8.20
FactoryTalk® ViewPoint 8.20
FactoryTalk® Services Platform 2.80
FactoryTalk® Alarms and Events 2.80
RSLinx® Enterprise 5.80
RSLinx® Classic 3.80
FactoryTalk® Activation 3.62.01
PUBLIC
www.rockwellautomation.com
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 90
Thank you!
top related