multi-therapy smart infusion for home care
Post on 06-Apr-2022
3 Views
Preview:
TRANSCRIPT
Multi-Therapy Smart Infusion for Home Care
CADD®-Solis VIP ambulatory infusion system
Tasks
100 mL Running
Continuous 7:15 AM
Continuous
Reservoir volume empty in 96 Hrs 0 Min
Tasks
265 mL Running
Intermittent 7:14 AM
Dosing
Dose complete in1 Hrs 0 Min
Tasks
500 mL Running
Taper 7:39 PM
Taper Up
Infusion complete in 12 Hrs 0 Min
Tasks
100 mL Running
PCA 7:16 AM
PCA Dosing
T
100 mL
Continuous
Reservoir volume empty in
Tasks
1,200 mL Running
Step 7:13 AM
Step
Current rate is 36 mL/hr
asks
Infusion complete in
Exit Accept Value
2,200 mL Stopped
Taper 1:15 PM AdultTPN mLAdultTPN m
'Accept Value', or press 'select' to edit
Infusion Volume 2,000 mL
Infusion Duration 12 Hrs 0 Min
Taper Up 1 Hrs 0 MinTaper Down 1 Hrs 0 Min
IN193561.indd 1 26-10-11 15:13
Exit Exit Exit Accept VAccept VAccept ValuealuealueAccept ValueAccept VAccept VAccept ValueAccept ValueAccept ValueAccept VAccept VAccept ValueAccept V
265 mL265 mL265 mL StoppedStoppedStopped
Intermittent Intermittent Intermittent 10:33 10:33 10:33 AM AM AM AM AM AM 24 Hour Bag (Antibiotic)24 Hour Bag (Antibiotic)24 Hour Bag (Antibiotic)24 Hour Bag (Antibiotic)Nafcillin 2gm Q6hrNafcillin 2gm Q6hrNafcillin 2gm Q6hrNafcillin 2gm Q6hr mLmLmL2224 Hour Bag 4 Hour Bag 4 Hour Bag (((AntibioticAntibioticAntibiotic)))NNNaaafffcillin 2gm cillin 2gm cillin 2gm QQQ6h6h6hr.r.r. mmm
'Accept V'Accept V'Accept V'Accept Value', or press 'select' to edialue', or press 'select' to edialue', or press 'select' to edialue', or press 'select' to edi'Accept Value', or press 'select' to edi'Accept V'Accept V'Accept Value', or press 'select' to edi'Accept Value', or press 'select' to edi'Accept Value', or press 'select' to edi'Accept V'Accept V'Accept Value', or press 'select' to edi'Accept V tttt'A'A'A'A t Vt Vt V l 'l 'l ' ' l' l' l t't't' t dt dt dititit
Dose VDose VDose VolumeolumeolumeDose VolumeDose VDose VDose VolumeDose VolumeDose VolumeDose VDose VDose VolumeDose V 61.561.561.5 mLmLmL
Dose RateDose RateDose Rate 61.5 61.5 61.5 mL/hmL/hmL/hrrr
Dose Cycle Dose Cycle Dose Cycle 6 6 6 HrsHrsHrs 0 0 0 MinMinMinDose Duration Dose Duration Dose Duration 1 1 1 HrsHrsHrs 0 0 0 MinMinMin
✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓✓
✓✓✓✓✓✓✓✓✓✓✓✓
✓✓✓✓✓✓✓✓✓✓✓✓
Status bar color coded for immediate visual indication of pump operating status
Protocol bar displays: therapy qualifierdrug name (units)
Soft key interfacemakes navigation easy
Keypad lock statusprovides clinician confidence that pump is locked
Drug concentration and/or units of measure
clearly displayed to help prevent medication errors
Infusion settings displays patient program settings
Cassette latchallows easy and secure attachment of CADD™ reservoirs and administration sets
Scroll keys eliminates numeric key press errors
CADD™ administration set or medication cassette reservoir
attaches easily and securely to the pump
PCA dose key enables convenient PCA dosing while ambulatory
Pump alarms differentiated by color and sound: red – high priority amber – medium priority blue – low priority
[Actual pump size]
CADD®-Solis VIP Ambulatory Infusion System with Safety Software
IN193561.indd 2 26-10-11 15:13
safe.simple.smart.
The CADD®-Solis VIP system provides
clinicians with confidence of reliable
pump performance, accurate
medication delivery, and ease of use.
It’s the first multi-therapy infusion
platform that is safe, simple and smart.
INFUSING CONFIDENCE
IN193561.indd 3 26-10-11 15:14
Developed with reliable CADD® technology that meets the new FDA infusion pump guidelines to promote patient safety
• Pharmacy PC programming standardizes pump parameters (including hard and soft limit entries) to help reduce the risk of errors
• Safety limits provide confidence in programming
• Visual soft limit override indication• CADD™ reservoirs promote medication
security and patient mobility
SAFE100 mL Stopped
PCA 7:20 AM High DoseMorphine 10 mg/mL
No Yes
Continuous Rate25.5 mg/hr
is greater than the soft limit.
Confirm soft limit override?
CHANGE CONFIRMATION SCREENHARD/SOFT LIMIT SCREEN
PCA 7:20 AM High DoseMorphine 10 mg/mL
100 mL
Continuous Rate
25.5
30
Don’t Save Confirm
IN193561.indd 4 26-10-11 15:14
• Large, clear screen displays instant status of therapy progress, battery life, and reservoir volume remaining
• Patented patient help screens assist with alarm trouble-shooting to help reduce clinician field visits
• Small and lightweight to promote increased patient mobility and improved quality of life
• Five therapy modes (Taper, Step, Intermittent, PCA, Continuous) for enhanced pediatric and adult patient outcomes
The patient-focused user interface helps reduce training time by providing therapy related information in an easy to understand format
SIMPLE
Stop Pump Next
Alarm- Downstream Occlusion
2,190 mL Paused
Taper 1:22 PM
Unkink Tubing.
HELP SCREENHOME SCREENHOME SCREEN
Tasks
2,200 mL Running
Taper 1:16 PM
Taper Up
Infusion complete in 12 Hrs 0 Min
IN193561.indd 5 26-10-11 15:14
• Organization-approved protocols promote standardization of workflows and help reduce pharmacy labor costs with PC pump programming
• Established PC software designed to reduce the risk of medication delivery errors
• Rechargeable battery reduces disposable battery expense
• Therapy-Qualifier-Drug programming sequence guides clinicians to patient-specific protocols
Graphs and reports provide trending data and delivery history for easy patient assessment, continuous quality improve-ment, and better patient outcomes
SMART
DOSING REPORT SCREEN DELIVERY HISTORY REPORT SCREEN
IN193561.indd 6 26-10-11 15:15
Delivery Mode Specifications
Tasks
100 mL Running
Continuous 7:15 AM
Continuous
Reservoir volume empty in 96 Hrs 0 Min
Tasks
265 mL Running
Intermittent 7:14 AM
Dosing
Dose complete in1 Hrs 0 Min
Tasks
500 mL Running
Taper 7:39 PM
Taper Up
Infusion complete in 12 Hrs 0 Min
Tasks
100 mL Running
PCA 7:16 AM
PCA Dosing
Tasks
1,200 mL Running
Step 7:13 AM
Step
Current rate is 36 mL/hr
PCA
Reservoir volume: 0 to 9999 mL
Delayed start: 0 to 96 hr in 5 min increments
Programming units: Milliliters (mL) Milligrams (mg) Micrograms (mcg)
Continuous rate: 0 to 500 mL/hr (or the mg or mcg equivalent)
PCA dose: 0 mL to 50 mL (or the mg or mcg equivalent)
PCA dose lockout: 1 minute to 24 hours
Max doses per hour: 1 to 60
Delivery limit amount: 0.1 to 1900 mL (or the mg or mcg equivalent)
Clinician bolus: 0 mL to 50 mL (or mg or mcg equivalent)
Maximum delivery rate (combined bolus and continuous rate): 40 to 250 mL/hr in increments of 1 mL
KVO rate: 0 mL/hr or 0.1 mL/hr
Continuous Reservoir volume: 0 to 9999 mL
Delayed start: 0 to 96 hr in 5 min increments
Continuous rate: 0.1 to 500 mL/hr
KVO rate: 0.1 to 10 mL/hr
IntermittentReservoir volume: 0 to 9999 mL
Delayed start: 0 to 96 hr in 5 min increments
Dose volume: 0.1 to 1000 mL
Dose duration: 1 min to 24 hr
Dose cycle: 10 min to 96 hr
Next dose start time: 0 to 96 hr in 5 min increments
KVO rate: 0 to 10 mL/hr
Step
Reservoir volume: 0 to 9999 mL
Delayed start: 0 to 96 hr in 5 min increments
Initial rate: 0.4 to 499 mL/hr
Plateau rate: 0.4 to 500 mL/hr
Rate increment: 0.4 to 499 mL/hr
Infusion volume: 1 to 9990 mL
Step duration: 15 min to 24 hr
KVO rate: 0 to 10 mL/hr
Step infusion alerts: On or Off
Number of steps: Unlimited, deter-mined by protocol
Taper
Reservoir volume: 0 to 9999 mL
Delayed start: 0 to 96 hr in 5 min increments
Infusion volume: 1 to 9990 mL
Taper up: 0 min to 99:40 hr:min
Taper down: 0 min to 99:40 hr:min
Infusion duration: 10 min to 99:50 hr:min
KVO rate: 0 to 10 mL/hr
Plateau rate upper limit: 0.1 to 500 mL/hr
CADD™-Solis Medication Safety Software
PC to pump programming helps decrease programming time and provides easy access to therapy data
Reduced risk of medication errors
A smart infusion system is designed to reduce the risk of medication errors by allowing therapy protocols with hard and soft limits to be downloaded to the pump through medication safety software1
IN193561.indd 7 26-10-11 15:15
Smiths Medical ASD, Inc.St. Paul, MN 55112, USAPhone: 1-214-618-0218Toll-Free USA: 1-800-258-5361www.smiths-medical.com
Smiths Medical is part of the global technology business Smiths Group plc. Product(s) described may not be licensed or available for sale in all countries. CADD, and the Smiths Medical and CADD design marks are trademarks of Smiths Medical. The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trademarks or service marks of their respective owners. Rx only. ©2011 Smiths Medical. All rights reserved. 9/11 IN193561
Find your local contact information at: www.smiths-medical.com/customer-support
Description Item Number
CADD®-Solis VIP Ambulatory Infusion PumpCADD®-Solis VIP ambulatory infusion pump, model 2120 21-2120-0100 Includes, pump key, 4 AA disposable batteries, Operator’s Manual, patient information guides, 2-year limited warrantyCADD™-Solis Medication Safety SoftwareCADD™-Solis medication safety software license (CD-ROM #21-2194) 21-2177
AccessoriesRemote dose cord 21-2186Power cord 21-2145
For use with AC adapter, item #21-2140Pump key 21-2185
For use with all CADD® pumpsAC Adapter 21-2140
For use with power cord, item #21-2145Battery pack, rechargeable 21-2160Battery door replacement 21-2184Lockable polemount bracket 21-6120Polemount adapter 21-2135
For use with lockable polemount bracket, item #21-6120Lockbox – clear 21-2188Lockbox – yellow 21-2189
Pump Carrying Cases50/100 mL CADD™ pump pouch 21-216550/100 mL CADD™ pump single use, black pouches, 10 pack 21-2170250/500 mL CADD™ pump pouch with waist belt 21-2167250/500 mL CADD™ pump pouch with waist belt and shoulder strap 21-2168250/500 mL CADD™ pump single use, black pouches, 10 pack 21-21711-liter CADD™ pump backpack 21-21663-liter CADD™ pump backpack 21-2169
Order Information
1. Medical Device Home Use Initiative – April 2010, Center for Devices and Radiological Health, US FDA.