MRIL®-Prime MagneticResonance Image Logging Tool
Reda Ayoubi Kilgore, TX
2FOR INTERNAL USE ONLY
OVERVIEW
MRIL®-Prime SAFETYo Permanent Magnetic Fieldo Tool weighto Electrical Safety and Precautionso Medical Implantso Fiberglass Sleeveso Tool Storage and Transportation
MRIL Origino Medicine vs. Oilfield
Features Subassemblies Tool Purpose Theory Log example Questions
3FOR INTERNAL USE ONLY
MRIL®-Prime SAFETY Permanent Magnetic Field The magnetic field is extremely strong near the Ferrite magnet
(150G) and twice that strength near the prepole Magnets.
Avoid bringing any metallic objects close to the sonde such as maintenance tools, steel toed shoes, metallic debris, catwalk, drillpipes, and other sondes.
Tool Weight The sonde (6” Mril Prime) weights 775 lbs. Never attempt to lift it
without appropriate lifting equipment.
Use a small portable crane or certified lifting straps to lift the sonde.
Avoid any impact to the sonde.
4FOR INTERNAL USE ONLY
Electrical Safety and Precautions
Check the leakage and continuity characteristics of your wireline.
Bleed-off the high voltage stored in the capacitor before physically disconnecting the tool string.
Always pay attention to proper power up and power down procedures when running the tool with other services.
Medical Implants
The magnetic field emitted by the sonde’s mandrel can cause discomfort for people using ferromagnetic implants.
Persons with medical implants must stay 10 feet from the MRIL tool.
5FOR INTERNAL USE ONLY
Fiberglass Sleeves
The fiberglass sleeve that surrounds the MRIL sonde can cause irritation and discomfort when it is directly in contact with skin.
Tool Storage and Transportation
Keep the sonde away from wireline drums and other tools that have photo-multiplier tubes. Some tools that could be affected from the housing magnetization include: D4TG, SDLT, NGRT, CSNG, PSGT
Use the MRIL tool transport truck or the MRIL transport rack for transportation purposes
6FOR INTERNAL USE ONLY
MRIL - New TechnologyMRIL - New TechnologyOil Field: NMR Tool
Medicine: MRI Instrument
Started in Medical Industry
NUMAR (1991) started “modern” NMR application in oil industry by using a permanent magnet and radio frequency.
7FOR INTERNAL USE ONLY
MRIL®-Prime features
Open hole centralized tool:slim sonde= 4.875-in. ODstandard sonde= 6-in. ODMRIL-XL sonde= 6-in. OD (decentralized)
Optimized with Nuclear Magnetic Resonance (NMR) principles.
Uses a permanent magnet and a pulsed radio frequency to analyze fluids in pore spaces of reservoir rock.
Measures porosity and other petrophysical parameters related to the productivity of hydrocarbons in the downhole environment.
8FOR INTERNAL USE ONLY
D4TG
Crossover Sub
MRCC-D
MREC-D
MRSN-D
Cable Head
24"
161.5"
166”
166"
81"
Diam: 3 5/8"Weight: 34 lbs.
Diam: 6"Weight: 775 lbs.
Diam: 3 5/8"Weight: 250 lbs.
Diam: 3 5/8"Weight: 275 lbs.
Weight: 110 lbs.
MRIL®-Prime SUBASSEMBLIES
D4TG/D4TS-NGRT Telemetry and Gamma Ray
MRICC The Capacitor cartridge stores the energy used by
the transmitter
MREC (instrument) Electronic cartridge provides transmission and
reception of NMR signals, data collection, and communication with the up-hole system.
MRIL-Prime sonde Relay sub connects the transmitter to capacitors. Two 1-foot pre-polarization “Prepole” Magnets. RF Antenna and Permanent Magnet. Equalization Sub filled with oil and a piston used
to equalize pressures.
9FOR INTERNAL USE ONLY
MRIL®-Prime PurposeMRIL tools can provide: Quantities of fluids in the rock
– Total porosity independent of lithology (TPHI)– Effective Porosity= Non Clay Porosity (MPHI)– Capillary bound water (MBVI)– Free Fluid (MFFI)
Properties of the fluids– Permeability profile along the well – Fluid Characterization (Water, Oil, and gas)– Viscosity (light or viscous oil)
Size of the pores that contains these fluids– Pore-Size Distribution
10FOR INTERNAL USE ONLY
What makes this tool different ?
11FOR INTERNAL USE ONLY
MRIL®-Prime Theory Nuclear Magnetic Resonance (NMR)
Response of atomic nuclei to magnetic fields.
All nuclei with an odd number of nucleons (such as 1H,13C, and 23Na) have a spin angular momentum and a magnetic moment.
They Behave like spining bar magnets and have a response
frequency (known as the Larmor frequency) which is related to the gyromagnetic ratio of an element and its magnetic field.
12FOR INTERNAL USE ONLY
NMR Implementation For Logging
Initially, the hydrogen protons are aligned randomly…
13FOR INTERNAL USE ONLY
Polarization
N
S
N
SN
S
N
S
N
S
N
S
N
S
N
S
N
SN
S
N
S N
SN
S
N
S
N
S
N
S
N
S
N
S
N
S
N
S
N
S
N
SN
S
N
S
Tw = 1 sec
14FOR INTERNAL USE ONLY
Polarization
Tw = 12 sec
N
S
N
SN
SN
S
N
S
N
S
N
S
N
S
N
S
N
S
N
SN
SN
S
N
S
N
SN
S
N
S
N
S
N
S
N
S
N
S
N
S
N
S
Imposing a fixed magnetic field and using RF signal on a group of nuclei causes them to behave in a predictable manner that can provide petrophysical information.
15FOR INTERNAL USE ONLY
Applying RF Pulse Using The Antenna
RF Pulse
N
S
N
SN
S
N
S
N
S
N
S
N
SNS
N
SN
S
NS
N
S
NS N
S
N
S
N
S
N
S
N
S
N
S
N
S
N
S
N
SN
S
N
S
16FOR INTERNAL USE ONLY
The Same Antenna Measure T2 Echo
Echo
N
S
N
SN
S
N
S
N
S
N
S
N
SNS
N
SN
S
NS
N
S
NS N
S
N
S
N
S
N
S
N
S
N
S
N
S
N
S
N
SN
S
N
S
Echo-Train
Time (mseg)
17FOR INTERNAL USE ONLY
MRIL Log Example
Track 1: Cumulative amplitudes from the binned T2-distribution.
Track 2:Mril Permeability.
Track 3:Travel time in a wave form.
Track 4: Hydrocarbon vs Water
top related