mr. bill ferguson newport, ar, 72112...apr 08, 2015 · newport, ar, 72112 ref: analytical testing...
Post on 25-Mar-2021
1 Views
Preview:
TRANSCRIPT
Laboratory's liability in any claim relating to analyses performed shall be limited to, at laboratory's option, repeating the analysis in question at laboratory's expense, or the refund of the charges paid for performance of said analysis. Alabama #40750 Louisiana #04015 VA NELAP #460181 Texas #T104704180‐11‐6 Arkansas #88‐0650 Mississippi California #2904 NC #415 Oklahoma #9311 Virginia #00106 Kentucky #90047 Tennessee #TN02027 EPA #TN00012 Kentucky UST #41 Kansas #E‐10396
4/14/2015 Arkansas Steel Mr. Bill Ferguson 2803 Van Dyke Road Newport, AR, 72112 Ref: Analytical Testing
ETC Report Number: 15-099-0206 Client Project Description: 001
Dear Mr. Bill Ferguson: Environmental Testing and Consulting, Inc. received sample(s) on 4/9/2015 for the analyses presented in the following report. The above referenced project has been analyzed per your instructions. The analyses were performed in accordance with the applicable analytical method. The analytical data has been validated using standard quality control measures performed as required by the analytical method. Quality Assurance, method validations, instrumentation maintenance and calibration for all parameters (NELAP and non-NELAP) were performed in accordance with guidelines established by the USEPA (including 40 CFR 136 Method Update Rule May 2012) and NELAC unless otherwise indicated. Any parameter for which the laboratory is not officially NELAP accredited is indicated by a '~' symbol. These are not included in the scope because NELAP accreditation is either not available or has not been applied for. Additional certifications may be held/are available for parameters, where NELAP accreditation is not required or applicable. A full list of certifications is available upon request. Per EPA Methods Update Rule (May 2012), all methods from Standard Methods for the Examination of Water and Wastewater are reported to include the year of approval. The results are shown on the attached Report of Analysis(s). Results for solid matrices are reported on an as-received basis unless otherwise indicated. This report shall not be reproduced except in full and relates only to the samples included in this report. Please do not hesitate to contact me or client services if you have any questions or need additional information. Sincerely,
Randy Thomas Project Manager
Page 1 of 4
AR 72112,
REPORT OF ANALYSIS
Report Date : 4/14/2015
Newport
Report Number : 15-099-0206 Received : 4/9/2015
03307
Mr. Bill Ferguson 001
Arkansas Steel
2803 Van Dyke Road
Project
Information :
Sample ID : #3 4/7-8/15 Sampled: 4/8/2015 12:00
Lab No : 95780
Test Results Units MQL By AnalyticalMethod
Date / TimeAnalyzed
DF
Matrix: Aqueous
10.0Chromium, Hexavalent <10.0 µg/L 1 04/09/15 09:50 3500CrB-2011TKM
0.500Total Arsenic 1.90 µg/L 1 04/13/15 22:32 EPA-200.8CGC
0.500Total Copper 23.7 µg/L 1 04/13/15 22:32 EPA-200.8CGC
100Total Iron 1940 µg/L 1 04/13/15 22:32 EPA-200.8CGC
1.00Total Manganese 665 µg/L 1 04/13/15 22:32 EPA-200.8CGC
Qualifiers/Definitions
Dilution FactorDFOutside QC limit*
Method Quantitation LimitMQL
Page 2 of 4
Fed Ex
UPS
US Postal
Client
Lab
Courier
Other :
Cooler Receipt Form
Customer Number:
Customer Name:Report Number: 15-099-0206
Arkansas Steel
03307
Shipping Method
Shipping container/cooler uncompromised?
Thermometer ID: #5
Chain of Custody (COC) present? Yes No
Yes No Not Required
Yes No Not Required
Yes No
COC agrees with sample label(s)? Yes No
COC properly completed
Samples in proper containers?
Sample containers intact?
Sufficient sample volume for indicated test(s)?
All samples received within holding time?
Cooler temperature in compliance?
Yes No
Yes No
Yes No
Yes No
Yes No
Yes NoCooler/Samples arrived at the laboratory on ice. Samples were considered acceptable as cooling process had begun.
Special precautions or instructions included? Yes No
Comments:
Yes No N/A
Yes No N/A
Yes No N/ASoil VOA method 5035 – compliance criteria met
Water - Sample containers properly preserved
Water - VOA vials free of headspace Yes No N/A
Trip Blanks received with VOAs
Low concentration EnCore samplers (48 hr)
High concentration pre-weighed (methanol -14 d) Low conc pre-weighed vials (Sod Bis -14 d)
High concentration container (48 hr)
Custody seals intact on shipping container/cooler?
Custody seals intact on sample bottles?
Number of coolers received
Yes No
1
Signature:
Any regulatory non-compliance issues will be recorded on non-compliance report.
Rebekah Ross Date & Time: 04/09/2015 09:11:10
Page 3 of 4
Page 4 of 4
top related