T-1
TITLE SHEET
TITLE SHEET T-1
SHEET INDEX PROJECT INFORMATION
Property Information:Site Name: CRAN_RSFR_SFOK2_016Site Number: SFOK2_016Site Address: ACROSS FROM: 1480 BROADWAY BURLINGAME, CA, 94010A.P.N. Number: ----Current Zoning: N/A - PUBLIC RIGHT OF WAYJurisdiction: BURLINGAMELatitude: N 37 35' 03.61"Longitude: W 122 21' 58.92"Elevation: 36± AMSL AT GROUND (NAVD 88)
Power Agency:PG&E1 MARKET STREET, SPEAR TOWERSAN FRANCISCO, CA 94105-1126
Telephone Agency:AT&T525 MARKET STREETSAN FRANCISCO, CA 94105ph: (415) 778-1231
PROJECT TEAM
Agent:Jimmy StillmanModus-Corporation, Inc.240 Stockton Street, 3rd FloorSan Francisco, CA 94108ph: (530) 913-9577email: jstillman@modus-corp.com
GENERAL CONTRACTOR NOTES
DO NOT SCALE DRAWINGS
THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 36" x 24" (D1). CONTRACTOR SHALL VERIFY ALLPLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELYNOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITHTHE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME.
DIRECTIONS FROM AT&T's OFFICEDIRECTIONS FROM AT&T's OFFICE AT 5001 EXECUTIVE PARKWAY, SAN RAMON, CA1. HEAD NORTHEAST ON BISHOP DR TOWARD SUNSET DR2. TURN RIGHT ONTO SUNSET DR3. USE THE RIGHT 2 LANES TO TURN RIGHT ONTO BOLLINGER CANYON RD4. USE THE RIGHT LANE TO MERGE ONTO I-680 S VIA THE RAMP TO SAN JOSE5. MERGE ONTO I-680 S6. TAKE EXIT 30B TO MERGE ONTO I-580 W TOWARD DUBLIN/OAKLAND7. KEEP LEFT AT THE FORK TO CONTINUE ON I-238 N, FOLLOW SIGNS FOR I-8808. USE THE RIGHT 2 LANES TO TAKE EXIT 16A FOR INTERSTATE 880 S TOWARD SAN JOSE/SAN MATEO
BRIDGE9. MERGE ONTO I-880 S10. USE THE RIGHT 2 LANES TO TAKE EXIT 27 TO MERGE ONTO CA-92 W TOWARD SAN MATEO
BRIDGE/JACKSON ST11. USE THE RIGHT 2 LANES TO TAKE EXIT 13B TO MERGE ONTO US-101 N TOWARD SAN FRANCISCO12. USE THE RIGHT 2 LANES TO TAKE EXIT 419B FOR BROADWAY13. TURN RIGHT ONTO BROADWAY14. 1480 BROADWAY
VICINITY MAPTHIS IS AN UNMANNED WIRELESS TELECOMMUNICATION FACILITY FOR AT&TMOBILITY CONSISTING OF THE INSTALLATION AND OPERATION OF AN ANTENNAAND ASSOCIATED EQUIPMENT ON AN EXISTING WOOD UTILITY POLE IN THEPUBLIC RIGHT OF WAY.
OCCUPANCY AND CONSTRUCTION TYPEOCCUPANCY : N/ACONSTRUCTION TYPE: G.O. 128 AND 2009 AASHTO 5TH EDITIONSTANDARD
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED INACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES ASADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESEPLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESECODES.
1. 2016 CALIFORNIA ADMINISTRATIVE CODES (INCL. TITLES 24 & 25)2. 2016 CALIFORNIA BUILDING CODE3. 2016 CALIFORNIA ELECTRICAL CODE4. 2016 CALIFORNIA MECHANICAL CODE5. 2016 CALIFORNIA PLUMBING CODE6. 2016 CALIFORNIA FIRE CODE7. 2016 CALIFORNIA GREEN BUILDING CODE8. 2016 CALIFORNIA ENERGY CODE9. 2016 SAN FRANCISCO CODE AMENDMENTS10. 2016 SAN FRANCISCO BUILDING CODE AMENDMENTS11. 2016 SAN FRANCISCO ELECTRICAL CODE AMENDMENTS12. 2016 SAN FRANCISCO MECHANICAL CODE AMENDMENTS13. 2016 SAN FRANCISCO PLUMBING CODE AMENDMENTS14. 2016 SAN FRANCISCO FIRE CODE AMENDMENTS15. 2016 SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS16. 2016 SAN FRANCISCO HOUSING CODE
DISABLED ACCESS REQUIREMENTSFACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITYREQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIABUILDING CODE, CODE OF REGULATIONS, TITLE 24, PART 2, VOLUME 1,CHAPTER 11B, DIVISION 2, SECTION 11B-203.5
CODE COMPLIANCE
SURVEYC-1
Project Manager:Jimmy StillmanModus-Corporation, Inc.240 Stockton Street, 3rd FloorSan Francisco, CA 94108ph: (530) 913-9577email: jstillman@modus-corp.com
Construction Manager:Kresston HaynesModus-Corporation, Inc.240 Stockton Street, 3rd FloorSan Francisco, CA 94108ph: (209) 938-7251email: khaynes@modus-corp.com
Architect / Engineer of Record:Borges Architectural Group, Inc.1478 Stone Point Drive, Suite 350Roseville, CA 95661contact: Brendan P. McNultyph: (916) 782-7200email: telecomgroup@borgesarch.com
AT&T Project Manager:Marc Grabisch, SAQ PMAT&T Mobility5001 Executive ParkwaySan Ramon, CA 94583ph: (925) 549-9671email: mg387k@att.com
RF Manager:Jeric LizardoAT&T Mobility5001 Executive ParkwaySan Ramon, CA 94583ph: (925) 365-0155email: j8771@att.com
SHEET NO. SHEET TITLE
SITE PLANA-1ENLARGED SITE PLAN & ANTENNA PLANA-2ELEVATIONSA-3
GENERAL NOTESGN-1
PROJECT DESCRIPTION
SCOPE OF WORK & SITE COMPLETION CHECKLIST
AT&T Construction Manager:Leo Ruazol, CX PMAT&T Mobility5001 Executive ParkwaySan Ramon, CA 94583ph: (650) 787-6814email: LR2164@att.com
SITE
Plot
Dat
e:6/
12/2
019
8:49
:00
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\T
-1 T
itle
Shee
t.dw
g
Plot
ted
By:
Bren
dan
McN
ulty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
DETAILSA-4.1
SINGLE LINE DIAGRAM & PANEL SCHEDULEE-1POLE GROUND & RISER DIAGRAM & DETAILSE-2
SITE NUMBER: SFOK2_016
FA#: 13789365
SITE NAME: CRAN_RSFR_SFK02_016
SITE ADDRESS: 1480 BROADWAY
BURLINGAME, CA, 94010
COUNTY: SAN MATEO
SITE TYPE: PG&E WOOD UTILITY POLE
HUB LOCATION: SNFCCA21 611 FOLSOM ST
POLE OWNER: JPA
· ANTENNA & ASSOCIATED EQUIPMENT BOXES - INSTALL A NEWTELECOMMUNICATION ANTENNA AND EQUIPMENT BOXES ON ANEXISTING WOOD UTILITY POLE ON GO95 COMPLIANT STANDOFF BRACKET.INSTALLATION CONSISTS OF (1) CANISTER ANTENNA, (2) TWIN DIPLEXERS,(1) 4415 RADIO WITH PSU-08 & (1) 4426 RADIO WITH PSU-08 IN SOLARSHIELDS , (1) SMARTPOLE METER, (1) LOAD CENTER.
· CABLING - CABLING TO BE INSTALLED IN A TIDY MANNER WITHOUT EXCESSCABLE LOOPS
· SPACING OF SUPPORT ELEMENTS - SUPPORT EQUIPMENT (E.G. RRUS) TO BECLUSTERED (VERTICALLY) AS CLOSE AS TECHNICALLY FEASIBLE ON POLE.
· LOGO REMOVAL - ALL EQUIPMENT LOGOS, OTHER THAN THOSE REQUIREDBY REGULATION (E.G. NODE IDENTIFICATION) SHALL BE PAINTED OVER ORREMOVED. RAISED OR DEPRESSED TEXT ON RRUS OR OTHER EQUIPMENT, IFPRESENT, SHALL BE SANDED OFF OR SIMILARLY REMOVED / FILLED.
· SIGNAGE - FCC MANDATED RF WARNING SIGNAGE SHALL FACE OUT TOSTREET WHEN PLACED IN FRONT OF, OR NEAR A WINDOW. SIGNAGESHALL FACE TOWARD A BUILDING IF THERE IS NO WINDOW.
· ALL CABLING, ANTENNAS, AND EQUIPMENT TO BE PAINTED TO MATCHPOLE
DETAILSA-4.2
-
Plot
Dat
e:6/
12/2
019
8:49
:11
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\G
N-1
Gen
eral
Not
es.d
wg
Pl
otte
d B
y:Br
end
an M
cNul
ty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
GN-1
GENERAL NOTES
1. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS, CONTRACT AND CONSTRUCTION DOCUMENTS.
2. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALLINSTALLATIONS AS INDICATED ON THE PLANS AND IN THE CONTRACT DOCUMENTS.
3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR(S) SHALL VISIT THE JOB SITE(S) AND BE RESPONSIBLE FOR ALL CONTRACTDOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRM THE WORK MAY BE ACCOMPLISHED PER THE CONTRACT DRAWINGS.ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ARCHITECT / ENGINEER PRIOR TOBID SUBMITTAL.
4. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED ON ANY WORK NOT CLEARLY DEFINED OR IDENTIFIED IN THECONTRACT AND CONSTRUCTION DOCUMENTS BEFORE STARTING ANY WORK.
5. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, ANDORDINANCES, INCLUDING APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS.
6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. IF THERECOMMENDATIONS ARE IN CONFLICT WITH THE CONTRACT AND CONSTRUCTION DOCUMENTS AND/OR APPLICABLE CODES ORREGULATIONS, REVIEW AND RESOLVE THE CONFLICT WITH DIRECTION FROM THE IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEEROF RECORD PRIOR TO PROCEEDING.
7. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, ANDPROCEDURES AND FOR COORDINATION OF ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT ANDCOORDINATION WITH THE IMPLEMENTATION ENGINEER AND WITH THE AUTHORIZED REPRESENTATIVE OF ANY OUTSIDE POLE OR PROPERTYOWNER.
8. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO PAVING,CURBS, VEGETATION, GALVANIZED SURFACE OR OTHER EXISTING ELEMENTS AND UPON COMPLETION OF THE WORK, REPAIR ANDDAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T MOBILITY.
9. CONTRACTOR IS TO KEEP THE GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVEEQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION DAILY.
10. PLANS ARE INTENDED TO BE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED UNLESS OTHERWISE NOTED. RELY ONLY ON ANNOTATEDDIMENSIONS AND REQUEST INFORMATION IF ADDITIONAL DIMENSIONS ARE REQUIRED.
11. THE EXISTENCE AND LOCATION OF UTILITIES AND OTHER AGENCY'S FACILITIES WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS.OTHER FACILITIES MAY EXIST. CONTRACTOR SHALL VERIFY LOCATIONS PRIOR TO START OF CONSTRUCTION AND USE EXTREME CARE ANDPROTECTIVE MEASURES TO PREVENT DAMAGE TO THE FACILITIES. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF UTILITIES OROTHER AGENCY'S FACILITIES WITHIN THE LIMITS OF THE WORK, WHETHER THEY ARE IDENTIFIED IN THE CONTRACT DOCUMENTS OR NOT.
12. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (800) 227-2600, AT LEAST TWO WORKING DAYS PRIOR TO START OF ANYEXCAVATION.
GENERAL NOTES:
DEFINITIONS:
1. "TYPICAL" OR "TYP" MEANS THAT THIS ITEM IS SUBSTANTIALLY THE SAME ACROSS SIMILAR CONDITIONS. "TYP" SHALL BE UNDERSTOOD TOMEAN "TYPICAL WHERE OCCURS" AND SHALL NOT BE CONSIDERED AS WITHOUT EXCEPTION OR CONSIDERATION OF SPECIFICCONDITIONS.
2. "SIMILAR" MEANS COMPARABLE TO CHARACTERISTICS FOR THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN.
3. "AS REQUIRED" MEANS AS REQUIRED BY REGULATORY REQUIREMENTS, BY REFERENCES STANDARDS, BY EXISTING CONDITIONS, BYGENERALLY ACCEPTED CONSTRUCTION PRACTICE, OR BY THE CONTRACT DOCUMENTS.
4. "ALIGN" MEANS ACCURATELY LOCATE FINISH FACES OF MATERIALS IN THE SAME PLANE.
5. THE TERM "VERIFY" OF "V.I.F." SHALL BE UNDERSTOOD TO MEAN "VERIFY IN FIELD WITH ENGINEER" AND REQUIRES THAT THE CONTRACTORCONFIRM INTENTION REGARDING NOTED CONDITION AND PROCEED ONLY AFTER RECEIVING DIRECTION.
6. WHERE THE WORDS "OR EQUAL" OR WORDS OF SIMILAR INTENT FOLLOW A MATERIAL SPECIFICATION, THEY SHALL BE UNDERSTOOD TOREQUIRE SIGNED APPROVAL OF ANY DEVIATION TO SAID SPECIFICATION PRIOR TO CONTRACTOR'S ORDERING OR INSTALLATION OF SUCHPROPOSED EQUAL PRODUCT.
7. "FURNISH" MEANS SUPPLY ONLY, OTHERS TO INSTALL.
8. "INSTALL" MEANS INSTALL ITEMS FURNISHED BY OTHERS.
9. "PROVIDE" MEANS FURNISH AND INSTALL.
OFFICE101 ROOM NUMBER
WALL TYPE MARK
KEYNOTE,CONSTRUCTION ITEM
KEYNOTE,DIMENSION ITEM
ROOM NAME
WALL SECTION
DETAIL
W- 3
BLDG. SECTIONA-3001
A-500D5
A-310A5
A-113C1
A-113C4
A-113A1
A-113A4 ELEVATION
3
2
CENTERLINE
ELEVATION DATUM
TILT-UP PANEL MARK
WINDOW SYMBOL
DOOR SYMBOL
PROPERTY LINE
3
±0"
001
10
A GRID/COLUMN LINE
A-3001
GROUT OR PLASTER
(E) BRICK
(E) MASONRY
CONCRETE
EARTH
GRAVEL
PLYWOOD
SAND
PLYWOOD
SAND
(E) STEEL
MATCH LINE
GROUND CONDUCTOR
TELEPHONE CONDUIT
POWER CONDUIT
COAXIAL CABLE
Tel
Pwr
Coax
CHAIN LINK FENCE
OVERHEAD SERVICE CONDUCTORSOH
WOOD FENCE
SYMBOL LEGEND:
A.B. ANCHOR BOLTABV. ABOVEACCA ANTENNA CABLE COVER ASSEMBLYADD'L ADDITIONALA.F.F. ABOVE FINISHED FLOORA.F.G. ABOVE FINISHED GRADEALUM. ALUMINUMALT. ALTERNATEANT. ANTENNAAPPRX. APPROXIMATE(LY)ARCH. ARCHITECT(URAL)AWG. AMERICAN WIRE GAUGEBLDG. BUILDINGBLK. BLOCKBLKG. BLOCKINGBM. BEAMB.N. BOUNDARY NAILINGBTCW. BARE TINNED COPPER WIREB.O.F. BOTTOM OF FOOTINGB/U BACK-UP CABINETCAB. CABINETCANT. CANTILEVER(ED)C.I.P. CAST IN PLACECLG. CEILINGCLR. CLEARCOL. COLUMNCONC. CONCRETECONN. CONNECTION(OR)CONST. CONSTRUCTIONCONT. CONTINUOUSd PENNY (NAILS)DBL. DOUBLEDEPT. DEPARTMENTD.F. DOUGLAS FIRDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDWG. DRAWING(S)DWL. DOWEL(S)EA. EACHEL. ELEVATIONELEC. ELECTRICALELEV. ELEVATOREMT. ELECTRICAL METALLIC TUBINGE.N. EDGE NAILENG. ENGINEEREQ. EQUALEXP. EXPANSIONEXST.(E) EXISTINGEXT. EXTERIORFAB. FABRICATION(OR)F.F. FINISH FLOORF.G. FINISH GRADEFIN. FINISH(ED)FLR. FLOORFDN. FOUNDATIONF.O.C. FACE OF CONCRETEF.O.M. FACE OF MASONRYF.O.S. FACE OF STUDF.O.W. FACE OF WALLF.S. FINISH SURFACEFT.( ' ) FOOT (FEET)FTG. FOOTINGG. GROWTH (CABINET)GA. GAUGEGI. GALVANIZE(D)G.F.I. GROUND FAULT CIRCUIT INTERRUPTERGLB. (GLU-LAM) GLUE LAMINATED BEAMGPS GLOBAL POSITIONING SYSTEMGRND. GROUNDHDR. HEADERHGR. HANGERHT. HEIGHTICGB. ISOLATED COPPER GROUND BUS
IN. ( " ) INCH(ES)INT. INTERIORLB.(#) POUND(S)L.B. LAG BOLTSL.F. LINEAR FEET (FOOT)L. LONG(ITUDINAL)MAS. MASONRYMAX. MAXIMUMM.B. MACHINE BOLTMECH. MECHANICALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSMTL. METAL(N) NEWNO.(#) NUMBERN.T.S. NOT TO SCALEO.C. ON CENTEROPNG. OPENINGP/C PRECAST CONCRETEPCS PERSONAL COMMUNICATION SERVICESPLY. PLYWOODPPC POWER PROTECTION CABINETPRC PRIMARY RADIO CABINETP.S.F. POUNDS PER SQUARE FOOTP.S.I. POUNDS PER SQUARE INCHP.T. PRESSURE TREATEDPWR. POWER (CABINET)QTY. QUANTITYRAD.(R) RADIUSREF. REFERENCEREINF. REINFORCEMENT(ING)REQ'D/ REQUIREDRGS. RIGID GALVANIZED STEELSCH. SCHEDULESHT. SHEETSIM. SIMILARSPEC. SPECIFICATIONSSQ. SQUARES.S. STAINLESS STEELSTD. STANDARDSTL. STEELSTRUC. STRUCTURALTEMP. TEMPORARYTHK. THICK(NESS)T.N. TOE NAILT.O.A. TOP OF ANTENNAT.O.C. TOP OF CURBT.O.F. TOP OF FOUNDATIONT.O.P. TOP OF PLATE (PARAPET)T.O.S. TOP OF STEELT.O.W. TOP OF WALLTYP. TYPICALU.G. UNDER GROUNDU.L. UNDERWRITERS LABORATORYU.N.O. UNLESS NOTED OTHERWISEV.I.F. VERIFY IN FIELDW WIDE (WIDTH)w/ WITHWD. WOODW.P. WEATHERPROOFWT. WEIGHTC CENTERLINEP PLATE, PROPERTY LINELL
ABBREVIATIONS:
-
17
1/8" = 1'-0"
OVERALL SITE PLAN
A-2
17
(E) WOOD UTILITY POLE
HT. 30.5'±
(E) TRAFFIC VAULT
(E) ELECTRICAL VAULT
(E) WOOD UTILITY POLE
(E) TRAFFIC VAULT
(E) GAS STATION SIGN
(E) LIGHT VAULT
(E) GAS VALVE
(E) TRAFFIC VAULT
(E) TRAFFIC
SIGNAL POLE
(E) OVERHEAD
UTILITY LINES
(E) TRAFFIC VAULT
(E) COMMUNICATION
VAULT
(E) TRAFFIC VAULT
(E) OVERHEAD
UTILITY LINES
(E) OVERHEAD
UTILITY LINES
(E) STREET LIGHT POLE
(E) WATER METER
(E) VAULT
(E) CONCRETE SIDEWALK
(E) CONCRETE SIDEWALK
(E) CONCRETE SIDEWALK
EL CAMINO REAL
BRO
ADW
AY
APN: 0026-212-280
(E) BUILDING
(E) BUILDING
APN: 0026-096-170
(E) GAS PUMP CANOPY
(E) GAS PUMP CANOPY
(
E
)
P
R
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
(
E
)
P
R
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
(
E
)
P
R
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
(E) LIP OF GUTTER
(E) OVERHEAD
UTILITY LINES
(E) STREET LIGHT
LEGEND:
WATER:
SANITARY SEWER:
STORM DRAIN:
OVERHEAD UTILITY LINES:
(P) ANTENNA MOUNTED ON TOP OF (E) UTILITYPOLE w/ (1) 4415 RADIO w/ PSU-08 & (1) 4426
RADIO W/ PSU-08 INSIDE (P) SOLAR SHIELDMOUNTED ON (E) UTILITY POLE
Plot
Dat
e:6/
12/2
019
8:49
:27
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\A
-1 S
ite P
lan.
dw
g
Plot
ted
By:
Bren
dan
McN
ulty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-1
SITE PLAN
8' 4' 8' 16'
1/8"=1'-0"
00
N
-
17
1/2" = 1'-0"
ENLARGED SITE PLAN
(E) OVERHEAD UTILITY LINE
(
E
)
P
R
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
A-2
5
(E) OVERHEAD UTILITY LINE
(E) BUILDING
(E) WOOD UTILITY POLE
HT. 30.5'±
(E) GAS STATION SIGN
(E) GAS VALVE
(E) TRAFFIC
SIGNAL POLE
(E) TRAFFIC VAULT
(E) STREET LIGHT POLE
(E) WATER METER
(E) VAULT
(E) LIP OF GUTTER
E
L
C
A
M
I
N
O
R
E
A
L
(E) CONCRETE SIDEWALK
LEGEND:
WATER:
SANITARY SEWER:
STORM DRAIN:
OVERHEAD UTILITY LINES:
(P) ANTENNA MOUNTED ON TOP OF (E) UTILITYPOLE w/ (1) 4415 RADIO w/ PSU-08 & (1) 4426
RADIO W/ PSU-08 INSIDE (P) SOLAR SHIELDMOUNTED ON (E) UTILITY POLE
5
1" = 1'-0"
ENLARGED ANTENNA PLAN
(P) ANTENNA MOUNTED ONTOP OF (E) UTILITY POLE
(P) 3" COAX RISER
(P) 1 1/2" AC POWER RISER
(P) (1) 4415 RADIO w/ PSU-08& (1) 4426 RADIO W/ PSU-08INSIDE (P) SOLAR SHIELDMOUNTED ON (E) UTILITY POLE
4
3" = 1'-0"
TWIN DIPLEXER DETAIL
TWIN DIPLEXER MAKE AND MODEL:
MANUFACTURER: COMMSCOPE
MODEL: CBC1923T-4310-E11F13P06
DIMENSIONS, HxWxD: 8.3" x 4.6" x 1.8"
WEIGHT: 5.5 lbs PER UNIT
4 5/8"
2 1/2"1 3/4"
TOP:
SIDE:FRONT:
8 3/8"
8 7/8
"
(2) TWIN DIPLEXERS
3
1" = 1'-0"
POWER METER MOUNTING DETAIL
12
3
6
(P) SMARTPOLE METER
9
4
"
NOTE: 30"X30"
UNOBSTRUCTED
CLIMBING SPACE
(P) 2" SQ. STEEL TUBE
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(P) 1 1/2" CONDUIT
(P) UNISTRUT P1000 OR EQ.
(P) 5/8" ANTI-SPLIT
GALVANIZED
THRU-BOLT (TYP)
(E) UTILITY POLE
8
1" = 1'-0"
RRUS-32 MOUNTING DETAIL
12
3
6NOTE: 30"X30"
UNOBSTRUCTED
CLIMBING SPACE
(P) 2" SQ. STEEL TUBE
(P) 5/8" ANTI-SPLIT
GALVANIZED
THRU-BOLT (TYP)
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(E) UTILITY POLE
(P) 1 1/2" CONDUIT
(P) 3" COAX CONDUIT
9
4
"
(1) (P) 4415 RADIO w/ PSU-08 & (1) (P) 4426
RADIO w/ PSU-08 INSIDE (P) SOLAR SHIELD
(P) UNISTRUT P1000 OR EQ.
8
1" = 1'-0"
RRUS-32 MOUNTING DETAIL
12
3
6NOTE: 30"X30"
UNOBSTRUCTED
CLIMBING SPACE
(P) 2" SQ. STEEL TUBE
(P) 5/8" ANTI-SPLIT
GALVANIZED
THRU-BOLT (TYP)
(P) 3/8" "C" ALUMINUM
CHANNEL, 8" WIDE
(E) UTILITY POLE
(P) 1 1/2" CONDUIT
(P) 3" COAX CONDUIT
9
4
"
(1) (P) 4415 RADIO w/ PSU-08 & (1) (P) 4426
RADIO w/ PSU-08 INSIDE (P) SOLAR SHIELD
(P) UNISTRUT P1000 OR EQ.
Plot
Dat
e:6/
12/2
019
8:50
:07
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\A
-2 E
nlar
ged
Site
Pla
n &
Ant
enna
Pla
n.d
wg
Pl
otte
d B
y:Br
end
an M
cNul
ty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-2
ENLARGED SITE
PLAN & ANTENNA
PLAN
1/2"=1'-0"
01'2' 2' 4'0
N
1' 0.5' 1' 2'0
1"=1'-0"
0
N
-
17 1/2" = 1'-0"EXISTING NORTH ELEVATION
(E) WOOD UTILITY POLE
0'-0" GRADE LEVEL
24'-0"TOP OF (E) UTILITY LINE AND ANCHOR POINT
28'-0"BOTTOM OF (E) LIGHT ARM
28'-11"TOP OF (E) STREET LIGHT
30'-6"TOP OF (E)WOOD UTILITY POLE
(E) STREET LIGHT
(E) UTILITY LINES ANDANCHOR POINTS
(E) ROW
(E) CONCRETE SIDEWALK
9 1/2" = 1'-0"PROPOSED NORTH ELEVATION
7
30'-6"TOP OF (E) WOOD UTILITY POLE
24'-0"TOP OF (E) UTILITY LINE AND ANCHOR POINT
(P) 2'-0" COMMUNICATIONSSAFETY ZONE PER GO95
0'-0"GROUND LEVEL
28'-0"BOTTOM OF (E) LIGHT ARM
28'-11"TOP OF (E) STREET LIGHT
(E) WOOD UTILITY POLE
(E) STREET LIGHT
(E) UTILITY LINES ANDANCHOR POINTS
(E) CONCRETE SIDEWALK
(P) AT&T ANTENNA MOUNTED TO(P) 7' EXTENSION ON TOP OF (E)
UTILITY POLE
(P) 6'-0" POWER SAFETYZONE PER GO 95
38'-9"RAD CENTER OF (P) AT&T ANTENNA
39'-10"TOP OF (P) AT&T ANTENNA
(P) 3" COAX RISER
(P) RF WARNING SIGN
37'-3"TOP OF COAX RISER / BOTTOM OF
(P) ANTENNA BRACKET
(P) AT&T FIBER P.O.C.
(P) 2" FIBER RISER FROM AT&T TO (P) FIBERDEMARK ENCLOSURE NEXT TO LOADCENTER ON POLE
(P) SMARTPOLE METER
(P) ELECTRIC LOAD CENTER
(P) SOLAR SHIELD TO HAVE SLATSON BOTH SIDES, TOP ANDBOTTOM TO REMAIN OPEN
16'-0"TOP OF (P) SOLAR SHIELD
7'-0"BOTTOM OF (P) LOAD CENTER
8'-1"TOP OF (P) LOAD CENTER
8'-7"BOTTOM OF (P) SMARTPOLE METER
9'-2"TOP OF (P) SMARTPOLE METER
10'-2"BOTTOM OF (P) SOLAR SHIELD
(P) 4426 RADIO w/PSU-08 INSIDE (P)SOLAR SHROUD
(P) 4415 RADIO w/ PSU-08, (P) (2)TWIN DIPLEXERS, AND (P)GROUND BAR INSIDE (P) SOLARSHROUD
(P) (2) TWIN DIPLEXERS
(P) GROUND BAR
Plot
Dat
e:6/
12/2
019
8:50
:32
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\A
-3 E
leva
tions
.dw
g
Plot
ted
By:
Bren
dan
McN
ulty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-3
ELEVATIONS
NOTES:1. PAINT RRU SOLAR SHIELD, MOUNTING COMPONENTS & CABLE SWEEP TO MATCH (E) POLE.
-
NEW 5-3/4" SQUAREWOOD EXTENSION FOR(E) WOOD UTILITY POLE
15 1" = 1'-0"CANISTER ANTENNA MOUNTING DETAIL
(P) 6"X6"X6"X1/4"TUBE STEEL CAP
(2) (P) 5/8" DIA. THRU BOLTS
(P) WAGON WHEEL FOR13" DIA RADOME
5 1' = 1'-0"NOTICE SIGNAGE
NOTICE
Transmitting Antenna(s)
Radio frequency fields beyond this point MAY
EXCEED the FCC General Population exposure limit.
Obey all posted signs and site guidelines
Call AT&T Mobility at 1 800-832-6662 PRIOR to
working beyond this point.
STATE:________SWITCH:__________________
SITE ID:_________________________________
SECTOR / NODE: ________________________
MINIMUM APPROACH DISTANCE = 6'-0"
NOTE:
SIGN BACKGROUND COLOR TO MATCH (E) POLE
ALL TEXT AND SYMBOLS TO BE WHITE
MINIMUM APPROACH DISTANCE - 6'
SFOK2_016
4 1" = 1'-0"WIRE DIAGRAM
CANISTERANTENNA
RET
RET
RET
RET
COAX COAX
CO
AX
COAX COAX
CO
AX
CO
AX
CO
AX
(P) (4) 1/2"SUPERFLEX COAX
(P) (4) 1/2"SUPERFLEX COAX
(P) RET CABLE
CO
AX
CO
AX
CO
AX
COAX
CO
AX
CO
AX
COAX
CO
AX
PLAN VIEW
NEW 3/8" C ALUMINUM
CHANNEL, 10" WIDE
NEW 2" SQ. STEEL TUBE OR
ROUND STOCK. 6" MIN. TYP.
OF 4
NEW 1/2"Ø MOUNTING
BOLT PER CABINET
BOLTING PATTERN
NEW UNISTRUT P1000
OR EQUAL (TYP.)- HORIZONTAL
- LENGTH AS REQUIRED PER
CABINET
5/8" Ø ANTI - SPLIT
GALVANIZED THRU BOLT
(TYP.)
EXISTING WOODEN
UTILITY POLE
RE
QU
IR
ED
VE
RIF
Y
PE
R
CA
BIN
ET
BO
LT
IN
G
PA
TT
ER
N
6" MIN
4" MIN
CLEARANCE
PER GO 95
(E) 1 1/2" CONDUIT
17
3/4" = 1'-0"
EQUIPMENT MOUNTING DETAIL
(N) 3" COAX CONDUIT
5/8" Ø ANTI - SPLIT
GALVANIZED THRU - BOLT
(TYP.)
NEW 3/8" C ALUMINUM CHANNEL, 6"
WIDE MIN.
NEW 1/2"Ø MOUNTING
BOLT (CONTRACTOR
TO VERIFY WITH
CABINET MFG. SPEC.)
NEW 2" SQ. STL. TUBE
STEEL
11
'-0
"
NOTE:
ALL CABINETS MOUNTED TO UTILITY POLE
SHALL HAVE A MINIMUM TOP & BOTTOM
CLEARANCE OF 7".
ELEVATION VEW
6"
1'-0
"2
'-5
"3
'-3
"3
'-4
"1
'-0
"
NEW UNISTRUT P 1000
OR EQUAL (TYP.)- HORIZONTAL -
LENGTH AS REQUIRED PER
CABINET 14
1 1/2" = 1'-0"
CONDUIT STRAP DETAIL
(E) WOOD UTILITY POLE
(P) 1/2" DIA. 3" ANTI-SPLIT
LAG SCREW
(P) 2-HOLE GALVANIZED
CONDUIT STRAP
(P) 3" COAX RISER
UPPER BRACKETSTEP
5/8'Ø X10" BOLT ANDLOCKNUT (SUPPLIED)
LOWER BRACKETSTEP
13/16" HOLES FOR3/4" BOLTS
BRACKET ADAPTER (FORPOLE TOP DIAMETERS LESSTHAN 8")
EXISTING POLE
EXTENSION BAYONET 53/4" SQUARE PRESSURETREATED DOUGLAS FIR
BRACKET ASSEMBLY(SEE DETAIL A)
ANTI- SPLIT BOLT
EXISTING POLE
DETAIL ABRACKET ASSEMBLY
NOTE:
NEW BRACKET ASSEMBLYTO BE PROVIDED BY UTILITYCOMPANY
DETAIL BWOOD EXTENSION
ASSEMBLY
12"
5"
7-1/2"
7-1/2"
7
3/4" = 1'-0"
WOOD POLE EXTENSION
9
3/4" = 1'-0"
ANTENNA EQUIPMENT FRONT ELEVATION
(P) ELECTRIC LOAD CENTER
(P) 2'-0" TELECOMMUNICATIONS
SAFETY ZONE AS PER GO95
(P) PLACE SHUT DOWN PROTOCOLS
ON THE INSIDE COVER OF THE LOAD
CENTER TO BE PROVIDED BY AT&T
(P) GROUND BAR
(P) (2) TWIN DIPLEXERS
(P) 4415 RADIO INSIDE
PROPOSED SOLAR
SHIELD w/ PSU-08
(P) 4426 RADIO INSIDE
PROPOSED SOLAR
SHIELD w/ PSU-08
(P) SMARTPOLE METER
1'-3"
9'-0"
1'-10"
7"
6"
1'-1"
1'-3"
1'-1"
1'-4"
1'-1"
2"
1
1' = 1'-0"
SHUT DOWN PROTOCOL SIGNAGE
NORMAL SHUT-DOWN PROTOCOLS:
1. CALL (800) 638-2588 NOC 24 HRS. PRIOR TO
SCHEDULE A SHUT-DOWN DAY AND TIME.
2. GIVE NOC THE NODE NUMBER _______________
3. ON SCHEDULED DAY OF SHUT-DOWN, PULL THE
DISCONNECT HANDLE TO THE *OFF* POSITION.
4. CAL NOC WHEN WORK IS COMPLETED.
EMERGENCY SHUT-DOWN PROTOCOLS:
1. CALL NOC (800) 638-2588
2. GIVE NOC THE NODE NUMBER _______________
3. PULL THE DISCONNECT HANDLE TO THE OFF POSITION.
4. CALL NOC WHEN WORK IS COMPLETED.
NOTE:
INSIDE AND OUTSIDE PANEL DOOR SHOWING
SHUT-DOWN PROTOCOL ON 3"X4" LABEL
SHUT DOWN DISCONNECT
1" = 1'-0"
FRONT SIDE
ELEC LOAD CENTER MAKE AND MODEL:MANUFACTURER: SQUARE D
MODEL: QO612L100RB
DIMENSIONS, HxWxD.in: 12.64" x8.9" x 4.27"
WEIGHT: 9.7 lbs
MOUNTING
BRACKET FOR (P)
EQUIPMENT
ELEC LOAD CENTER
8.9"
TOP
12.64"
4.27"
NOTE:RF SHUTDOWN SIGNAGE TO BE ON THEINSIDE AND OUTSIDE OF THE LOAD CENTER
3 1 1/2" = 1'-0"CANISTER ANTENNA
9.45"
ANTENNA = CANISTERWEIGHT = 33.1 LBSCONNECTOR = 10 X 4.3-10 DIN (FEMALE) / BOTTOMDIMENSIONS = 9.45"(DIA.) X 23.63"
23.6
3"
16
3" = 1'-0"
SMART POLE METER DETAIL
NOTES:
1. PG&E CODE #M241490 & #M241572
2. PG&E TO PERFORM RF SIGNAL TEST.
3. INSTALL IN STRICT ACCODANCE WITH PG&E UTILITY
BULLETIN FOR SMARTPOLE METER SERVICE
PG&E SMARTPOLE METER DIMENSIONS:
DIAMETER: +/- 4.63"
HEIGHT: +/- 7.17"
WEIGHT: +/- 12 LBS
7.1
7"
4.18"4.11"
4.63"
4.1
2"
3 POLE, 3 WIRE
LOCKING
RECEPTACLE
NEMA 3R
ENCLOSURE
BOX
A-4.1
DETAILS
Plot
Dat
e:6/
12/2
019
8:52
:28
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\A
-4.1
Det
ails.
dw
g
Plot
ted
By:
Bren
dan
McN
ulty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
-
1
1 1/2" = 1'-0"
RRUS 4415
ERICSSON RRUS-4415 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 14.96" TALL X 13.19" WIDE X 5.39" DEEP (INCLUDING SUNSHIELD)
VOLUME: 0.6155 CU. FT.
WEIGHT: +/- 44.0 LBS. (EXCLUDING MOUNTING HARDWARE)
SIDE VIEW
MFR'S STANDARD MOUNTING BRACKETS
TOP VIEW
MFR'S STANDARD
MOUNTING
BRACKETS
SUNSHIELD
RRUS WITH SUNSHIELD
12" C
LR
.16" C
LR
.
FRONT VIEW
MOUNTING POLE
14.96
5.3913.19"
5
1 1/2" = 1'-0"
RRUS 4426
ERICSSON RRUS 4426 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 14.9" TALL X 13.19" WIDE X 5.8" DEEP (INCLUDING SUNSHIELD)
WIEGHT: +/- 48.5 LBS. (EXCLUDING MOUNTING HARDWARE)
SIDE VIEW
PSU-08
TOP VIEW
P1000 UNISTRUT
PSU-08
SUNSHIELD
RRUS WITH SUNSHIELD
12" C
LR
.16" C
LR
.
FRONT VIEW
MOUNTING CHANNEL
5.8
14.96
13.19
Plot
Dat
e:6/
12/2
019
8:52
:52
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\A
-4.2
Det
ails.
dw
g
Plot
ted
By:
Bren
dan
McN
ulty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
A-4.2
DETAILS
-
EMERGENCY SHUTDOWNDISCONNECT SWITCH LOCATEDABOVE ELECTRIC LOAD CENTER
3"
4"
NOTE:
NEW VINYL SIGN TO BE PROVIDED BY AT&T AND BE LOCATED ONTHE SIDE OF THE METER BOX. SIGN TO BE YELLOW.
4 NOT TO SCALESHUTDOWN DISCONNECT SIGNAGE
Plot
Dat
e:6/
12/2
019
8:53
:07
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\E
-1 S
ING
LE L
INE
DIA
GRA
M &
PA
NEL
SC
HED
ULE.
dw
g
Plot
ted
By:
Bren
dan
McN
ulty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
E-1
SINGLE LINE
DIAGRAM & PANEL
SCHEDULE
ELECTRICAL NOTES
GENERAL REQUIREMENTS:
1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST RULES ANDREGULATIONS OF THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES.NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE CONSTRUED AS TO PERMITWORK NOT CONFORMING TO THE MOST STRINGENT OF THESE CODES. SHOULDCHANGES BE NECESSARY IN THE DRAWINGS OR SPECIFICATIONS TO MAKE THE WORKCOMPLY WITH THESE REQUIREMENTS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THEARCHITECT IN WRITING AND CEASE WORK ON PARTS OF THE CONTRACT WHICH AREAFFECTED.
2. THE CONTRACTOR SHALL MAKE A SITE VISIT PRIOR TO BIDDING AND CONSTRUCTION TOVERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY ARCHITECT IMMEDIATELY UPONDISCOVERY OF ANY DISCREPANCIES. THE CONTRACTOR ASSUMES ALL LIABILITY FORFAILURE TO COMPLY WITH THIS PROVISION.
3. THE EXTENT OF THE WORK IS INDICATED BY THE DRAWINGS, SCHEDULES, ANDSPECIFICATIONS AND IS SUBJECT TO THE TERMS AND CONDITIONS OF THE CONTRACT.THE WORK SHALL CONSIST OF FURNISHING ALL LABOR, EQUIPMENT, MATERIALS, ANDSUPPLIES NECESSARY FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. THEWORK SHALL ALSO INCLUDE THE COMPLETION OF ALL ELECTRICAL WORK NOTMENTIONED OR SHOWN WHICH IS NECESSARY FOR SUCCESSFUL OPERATION OF ALLSYSTEMS.
4. THE CONTRACTOR SHALL PREPARE A BID FOR A COMPLETE AND OPERATIONAL SYSTEM,WHICH INCLUDES THE COST FOR MATERIAL AND LABOR.
5. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE OPERATION.DEFECTIVE OR DAMAGED MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINALACCEPTANCE IN A MANNER ACCEPTABLE TO OWNER AND ENGINEER.
6. COMPLETE THE ENTIRE INSTALLATION AS SOON AS THE PROGRESS OF THE WORK WILLPERMIT. ARRANGE ANY OUTAGE OF SERVICE WITH THE OWNER AND BUILDINGMANAGER IN ADVANCE. MINIMIZE DOWNTIME ON THE BUILDING ELECTRICAL SYSTEM.
7. THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT SHALL BE DELIVERED INPROPER WORKING ORDER. REPLACE, WITHOUT ADDITIONAL COST TO THE OWNER, ANYDEFECTIVE MATERIAL AND EQUIPMENT WITHIN ONE YEAR FROM THE DATE OF FINALACCEPTANCE.
8. ANY ERROR, OMISSION OR DESIGN DESCREPANCY ON THE DRWINGS SHALL BE BROUGHTTO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION OR CORRECTION BEFORECONSTRUCTION.
9. "PROVIDE" INDICATES THAT ALL ITEMS ARE TO BE FURNISHED, INSTALLED ANDCONNECTED IN PLACE.
10. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND PAY ALLREQUIRED FEES.
EQUIPMENT LOCATION:
1. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS ORARRANGEMENTS OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BEFOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGEMENT MUST BE EXERCISED INEXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THEAVAILABLE SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONSENCOUNTERED.
2. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR ARRANGEMENTS ARENECESSARY, DUE TO FIELD CONDITIONS IN THE BUILDING CONSTRUCTION ORREARRANGEMENT OF FURNISHINGS OR EQUIPMENT, SUCH CHANGES SHALL BE MADEWITHOUT COST, PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, ETC.,AND WORK DIRECTLY CONNECTED TO THE SAME IS INSTALLED AND NO EXTRA MATERIALSARE REQUIRED.
3. LIGHTING FIXTURES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS ONLY. COORDINATETHE FIXTURE LOCATION WITH MECHANICAL EQUIPMENT TO AVOID INTERFERENCE.
4. COORDINATE THE WORK OF THIS SECTION WITH THAT OF ALL OTHER TRADES, WHERECONFLICTS OCCUR, CONSULT WITH THE RESPECTIVE CONTRACTOR AND COME TOAGREEMENT AS TO CHANGES NECESSARY, OBTAIN WRITTEN ACCEPTANCE FROMENGINEER FOR THE PROPOSED CHANGES BEFORE PROCEEDING.
SHOP DRAWINGS:
1. N/A UNLESS NOTED OTHERWISE.
SUBSTITUTIONS:
1. NO SUBSTITUTIONS ARE ALLOWED
TESTS:
1. BEFORE FINAL ACCEPTANCE OF WORK, THE CONTRACTOR SHALL INSURE THAT ALLEQUIPMENT, SYSTEMS, FIXTURES, ETC., ARE WORKING SATISFACTORILY AND TO THE INTENTOF THE DRAWINGS.
PERMITS:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING OUT AND PAYING FOR ALLREQUIRED PERMITS, INSPECTION AND EXAMINATION WITHOUT ADDITIONAL EXPENSE TOTHE OWNER.
GROUNDING:
1. THE CONTRACTOR SHALL PROVIDE A COMPLETE, AND APPROVED GROUNDING SYSTEMINCLUDING ELECTRODES, ELECTRODE CONDUCTOR, BONDING CONDUCTORS, ANDEQUIPMENT CONDUCTORS AS REQUIRED BY ARTICLE 250 OF THE NATIONAL ELECTRICALCODE.
2. CONDUITS CONNECTED TO EQUIPMENT AND DEVICES SHALL BE METALICALY JOINEDTOGETHER TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY.
3. FEEDERS AND BRANCH CIRCUIT WIRING INSTALLED IN A NONMETALLIC CONDUIT SHALLINCLUDE A CODE SIZED GROUNDING CONDUCTOR HAVING GREEN INSULATION. THEGROUND CONDUCTOR SHALL BE PROPERLY CONNECTED AT BOTH ENDS TO MAINTAINELECTRICAL CONTINUITY.
4. REFER TO GROUND BUS DETAILS. PROVIDE NEW GROUND SYSTEM COMPLETE WITHCONDUCTORS, GROUND ROD AND DESCRIBED TERMINATIONS.
5. ALL GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER AND ANNEALED #2UNLESS NOTED OTHERWISE.
6. ALL NON-DIRECT BURIED TELEPHONE EQUIPMENT GROUND CONDUCTORS SHALL BE #2STRANDED THHN (GREEN) INSULATION.
7. ALL GROUND CONNECTIONS SHALL BE MADE WITH "HYGROUND" COMPRESSION SYSTEMBURNDY CONNECTORS EXCEPT WHERE NOTED OTHERWISE.
8. PAINT AT ALL GROUND CONNECTIONS SHALL BE REMOVED.
9. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUEIS EXCEEDED, NOTIFY THE OWNER FOR FUTURE INSTRUCTION ON METHODS FORREDUCING THE RESISTANCE VALUE. SUBMIT TEST REPORTS AND FURNISH TO SMART SMRONE COMPLETE SET OF PRINTS SHOWING "INSTALLED WORK".
UTILITY SERVICE:
1. TELEPHONE AND ELECTRICAL METERING FACILITIES SHALL CONFORM TO THEREQUIREMENTS OF THE SERVING UTILITY COMPANIES. CONTRACTOR SHALL VERIFYSERVICE LOCATIONS AND REQUIREMENTS. SERVICE INFORMATION WILL BE FURNISHED BYTHE SERVING UTILITIES.
2. CONFORM TO ALL REQUIREMENTS OF THE SERVING UTILITY COMPANIES.
PRODUCTS:
1. ALL MATERIALS SHALL BE NEW, CONFORMING WITH NEC, ANSI, NEMA, AND THEY SHALLBE U.L. LISTED AND LABELED.
2. CONDUIT: A) RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC
INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS,IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLSOR EXPOSED ON BUILDING EXTERIOR, RIGID CONDUIT IN CONTACT WITH EARTHSHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO. 3.
B) ELECTRICAL METALLIC TUBING SHALL U.L. LABEL, FITTINGS SHALL BECOMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS.
C) FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USEDWHERE PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE. SEALTIGHT FLEXIBLE CONDUIT. ALL CONDUIT EXCESS OF SIX FEET IN LENGTH SHALLHAVE FULL SIZE GROUND WIRE.
D) CONDUIT RUNS MAY BE SURFACE MOUNTED IN CEILING OR WALLS UNLESSINDICATED OTHERWISE. CONDUIT INDICATED SHALL RUN PARALLEL OR AT RIGHTANGLES TO CEILING, FLOOR OR BEAMS. VERIFY EXACT ROUTING OF ALLEXPOSED CONDUIT WITH ARCHITECT PRIOR TO INSTALLING.
E) ALL UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 40 (UNLEES NOTEDOTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE
F) ALL CONDUIT ONLY (C.O.) SHALL HAVE PULL ROPE.
G) CONDUITS RUN ON ROOFS SHALL BE INSTALLED ON 4x4 REDWOOD SLEEPERS,6'-0" ON CENTER, SET IN NON-HARDENING MASTIC.
3. ALL WIRE AND CABLE SHALL BE COPPER, 600 VOLT, #12 AWG MINIMUM UNLESSSPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CONDUCTORS #10 AWG ANDSMALLER SHALL BE SOLID. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED.TYPE THHN INSULATION USED UNLESS CONDUCTORS INSTALLED IN CONDUIT EXPOSED TOWEATHER, IN WHICH CASE TYPE THWN INSULATION SHALL BE USED.
4. PROVIDE GALVANIZED COATED STEEL BOXES AND ACCESSORIES SIZED PER CODE TOACCOMMODATE ALL DEVICES AND WIRING.
5. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE WITH WHITE FINISH (UNLESSNOTED BY ENGINEER), 20 AMP, 125 VOLT, THREE WIRE GROUNDING TYPE, NEMA 5-20R.MOUNT RECEPTACLE AT +12" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED ONDRAWINGS OR IN DETAILS. WEATHERPROOF RECEPTACLES SHALL BE GROUND FAULTINTERRUPTER TYPE WITH SIERRA #WPD-8 LIFT COVERPLATES.
6. TOGGLE SWITCHES SHALL BE 20 AMP, 120 VOLT AC, SPECIFICATION GRADE WHITE(UNLESS NOTED OTHERWISE) FINISH. MOUNT SWITCHES AT +48" ABOVE FINISHED FLOOR.
7. PANELBOARDS SHALL BE DEAD FRONT SAFETY TYPE WITH ANTI-BURN SOLDERLESSCOMPRESSION APPROVED FOR COPPER CONDUCTORS, COPPER BUS BARS, FULL SIZEDNEUTRAL BUS, GROUND BUS AND EQUIPPED WITH QUICK-MAKE QUICK-BREAK BOLT-INTYPE THERMAL MAGNETIC CIRCUIT BREAKERS. MOUNT TOP OF THE PANELBOARDS AT6'-3" ABOVE FINISHED FLOOR. PROVIDE TYPE WRITTEN CIRCUIT DIRECTORY.
8. ALL CIRCUIT BREAKERS, MAGNETIC STARTERS AND OTHER ELECTRICAL EQUIPMENT SHALLHAVE AN INTERRUPTING RATING NOT LESS THAN MAXIMUM SHORT CIRCUIT CURRENT TOWHICH THEY MAY BE SUBJECTED.
9. GROUND RODS SHALL BE COPPER CLAD STEEL, 5/8" ROUND AND 10' LONG.COPPERWELD OR APPROVED EQUAL.
INSTALLATION:
1. PROVIDE SUPPORTING DEVICES FOR ALL ELECTRICAL EQUIPMENT, FIXTURES, BOXES,PANEL, ETC., SUPPORT LUMINARIES FROM UNDERSIDE OF STRUCTURAL CEILING,EQUIPMENT SHALL BE BRACED TO WITHSTAND HORIZONTAL FORCES IN ACCORDANCEWITH STATE AND LOCAL CODE REQUIREMENTS. PROVIDE PRIOR ALIGNMENT ANDLEVELING OF ALL DEVICES AND FIXTURES.
2. CUTTING, PATCHING, CHASES, OPENINGS: PROVIDE LAYOUT IN ADVANCE TO ELIMINATEUNNECESSARY CUTTING OR DRILLING OF WALLS, FLOORS CEILINGS, AND ROOFS. ANYDAMAGE TO BUILDING STRUCTURE OR EQUIPMENT SHALL BE REPAIRED BY THECONTRACTOR. OBTAIN PERMISSION FROM THE ENGINEER BEFORE CORING.
3. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORINGPURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS,ETC., IT MUST BE CLEARLY UNDERSTOOD THAT TENDONS AND/OR REINFORCING STEELWILL NOT BE DRILLED INTO, CUT OR DAMAED UNDER THE CIRCUMSTANCES.
4. LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT DEFINITELY KNOWN ANDTHEREFORE, MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT VIAX-RAY OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/ORSTEEL TENDONS.
5. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THEREQUIREMENTS OF THE C.B.C.
PROJECT CLOSEOUT:
1. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALLPOTENTIAL GROUNDING TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECTMANAGER. CLEAN PREMISES OF ALLS DEBRIS RESULTING FROM WORK AND LEAVE WORKIN A COMPLETE AND UNDAMAGED CONDITION.
2. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL "AS INSTALLED"DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS,ROUTINGS AND CIRCUITS.
3. ALL BROCHURES, OPERATING MANUALS, CATALOG, SHOP DRAWINGS, ETC., SHALL BETURNED OVER TO OWNER AT JOB COMPLETION.
GROUNDING NOTES:
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATIONREQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE CONDITIONS.
2. ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESSOTHERWISE NOTED.
3. GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED, FURNISHED ANDINSTALLED BY THE VENDOR.
4. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE, ABOVE GRADECONNECTIONS: EXOTHERMIC WELD TYPE.
5. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUMBELOW THE FROST LINE.
6. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROMEQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE.
7. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLDGALVANIZED SPRAY.
8. GROUND BARS: A) EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT THE BOTTOM OF ANTENNA
POLE/MAST FOR MAKING GROUNDING JUMPER CONNECTIONS TO COAXFEEDER CABLES SHALL BE FURNISHED AND INSTALLED BY ELECTRICALCONTRACTOR. JUMPERS (FURNISHED BY OWNERS) SHALL BE INSTALLED ANDCONNECTED BY ELECTRICAL CONTRACTOR.
9. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICALCONTRACTOR.
10. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICEGROUNDING.
11. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'SRECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM).
12. IF EQUIPMENT IS IN A C.L. FENCE ENCLOSURE, GROUND ONLY CORNER POSTS ANDSUPPORT POSTS OF GATE. IF CHAIN LINK LID IS USED, THEN GROUND LID ALSO.
13. GROUNDING AT PPC CABINET SHALL BE VERTICALLY INSTALLED.
14. ALL GROUNDING FOR ANTENNAS SHALL BE CONNECTED SO THAT IT WILL BY-PASS MAINBUSS BAR.
15. ALL EMT RUNS SHALL BE GROUNDED AND HAVE A BUSHING, NO PVC ABOVE GROUND.
16. USE SEPARATE HOLES FOR GROUNDING AT BUSS BAR. NO "DOUBLE-UP" OF LUGS.
17. POWER AND TELCO CABINETS SHALL BE GROUNDED (BONDED) TOGETHER.
18. NO LB'S ALLOWED ON GROUNDING.
19. PROVIDE STAINLESS STEEL CLAMP AND BRASS TAGS ON COAX AT ANTENNAS ANDDOGHOUSE.
5 N.T.S.ELECTRICAL NOTES
M
(1) 3" C(2) 4/0 THWN AL(1) 1/0 AL NEUTRAL
METER
N G
#2 GROUNDING ELECTRODE, #2BOND TO GROUNDING ROD
UTILITY
DISTRIBUTION PANEL100 AMP, 1 PHASE, 120/240V AC6 POSITION LOAD CENTER
N G
30/2
#2 GROUNDING ELECTRODECONDUCTOR TO GROUND RING
100/2 - MAIN BREAKER
RG
30/2
RRH RRH
(2) RRH
(1) 4" C(4) 1/2" COAX
1 1/2" C (3) #3/0, (1) #2 GROUND
1 1/2" C (3) #10, (1) #10 GROUND
1 1/2" C (3) #10, (1) #10 GROUND
ANTENNA
PSU-08PSU-08
-
NEW 3/8" DIA. HARDWOODMOLDING
NEW GALV IRON MOLDINGSTAPLE TYP
NEW 1/2" PVC CONDUIT FORMETER GROUND
6"MIN
TYP MECHANICALCONNECTION
5/8" DIA. X 10'GROUND ROD
NEW GROUND CONDUCTOR#2 GREEN COATED SOLID
COPPER WIRE
18"
GROUND LEGENDMECHANICAL CONNECTION
EXOTHERMIC CADWELD
TYP 5/8" DIA. X 10' LONG COPPER CLAD GROUNDROD AT 10' O.C. MAX AND 18" MIN BELOW FINISH GRADE
15 1" = 1'-0"GROUND DETAIL
EXISTING GRADE
5
1/2" = 1'-0"
GROUNDING PLAN
(P) 5/8" X 10" GROUNDING ROD
(P) CADWELD CONNECTION TYPE "GRI" MOLD
(P) MECHANICAL CONNECTION
(P) #2 GREEN COATED SOLID COPPER
WIRE ENCASED WITHIN WOODEN
MOLDING CONNECTED WITH
GALVANIZED STEEL STRAPS AT 3'-0"
O.C. PER PG& E REQUIREMENTS
(P) ANTENNA GROUND
(P) ANTENNA MAST GROUND
Plot
Dat
e:6/
12/2
019
8:53
:29
AM
F
ile N
ameT
:\20
16\T
-165
09_M
odus
_SF_
CRA
N_A
T&T\
SFO
K2_0
16-8
5\SF
OK2
_016
\She
ets\
Build
ing
A\E
-2 P
OLE
GRO
UND
& R
ISER
DIA
GRA
M &
DET
AIL
S.d
wg
Pl
otte
d B
y:Br
end
an M
cNul
ty
1478 STONE POINT DRIVE, SUITE 350
ROSEVILLE CA 95661
TEL
FAX
borgesarch.com
916 782 7200
916 773 3037
SHEET NO.
SHEET TITLE
DRAWN BY: A.P.E.
CHECK BY: B.P.M.
PROJECT NO.: T-16509-85
STAMP
REV DESCRIPTIONDATE
240 STOCKTON STREET, 3RD FLOORSAN FRANCISCO, CA 94108
modus-corp.com
5001 EXECUTIVE PARKWAY
SAN RAMON, CA 94583
No. C11535
0 09/13/17 90% CD Submittal
SITE NUMBER:
SFOK2_016
SITE ADDRESS:
1480 BROADWAY
BURLINGAME, CA, 94010
1 09/25/17 100% CD Submittal
2 02/22/18 100% CD Rev 1
3 06/11/19 100% CD Rev 2
E-2
POLE GROUND &
RISER DIAGRAM &
DETAILS