maxima 35c modena he - ferroli€¦ · 1 x modena c he boiler 1 x installation instructions 1 x...
Post on 10-Oct-2020
0 Views
Preview:
TRANSCRIPT
ferroli
Boiler Replacement
Maxima 35C- Modena HE
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
The Installation must comply with the following;
Gas Safety (Installation & Use)Regulations
The Building Regulations
The Building Regulations (Scotland)
Building Regulations (Northern Ireland)
The Water Fittings Regulations or WaterByelaws in Scotland
The Current I.E.E. Wiring Regulations-------------------------------------------------------
BS 5440: Part 1 - Flues.
BS 5440: Part 2 - Ventilation.
BS 6798 - Installation of gas fired hotwater boilers
BS 7671: - Electrical wiring
BS 6891 - Gas Installation
BS 5546 - Installation of hot watersupplies for domestic purposes.
BS 5449 - Forced circulation hot watersystems
BS 7074 - Expansion vessels / sealedsystems
BS 7593 - Treatment of water in domesticcentral heating systems.
Introduction
Although the new Ferroli Modena 32C HE high efficiency condensing combination boiler has an
output slightly less than that of the Ferroli Maxima 35C it will, in the vast majority of cases, be an
ideal replacement.
The installer will need to check the overall heating requirements of the property, but rarely is the
maximum output required solely for central heating; often the main concern being related to the
performance of the domestic hot water.
The DHW performance of the new Ferroli Modena 32C HE is almost equal to that of the Maxima 35C
(@ ∆t 300; Modena 32C HE = 15.3 l/m - Maxima 35C = 16.5 l/m)
The Ferroli Modena C HE is smaller, weighs less, has built-in frost protection and an IP protection
rating of IPX5D. This allows direct replacement wherever the existing boiler is legitimately installed
(i.e. Kitchen, Garage, Bathroom, etc.)
Although the actual position of the pipe-work connections differ slightly, the configuration remains
the same, thereby requiring only limited pipe-work alteration.
The electrical connection remains the same, i.e. all models supplied with a factory fitted three core fly - lead to provide a permanent live connection and all models use the same volt free contacts for any external system controls. The flue outlet connection on the new Modena C HE is centrally aligned and is therefore completely compatible with the earlier Ferroli Maxima 35C.
-----------------------------------------------------------------------------------------------------------------------------
Please note:
This guide refers to the fitting of a replacement boiler with a standard horizontal flue application only (minor adjustments may be necessary for other flue applications – refer to boiler installation instructions)
The work procedures described in this document must
be completed strictly in accordance with the
manufacturer’s installation instructions, current
regulations and relevant standards, and only by
competent person/persons as stated in the Gas Safety
(Installation & Use) Regulations.
Prior to fitting the replacement boiler the entire system
must be thoroughly cleansed and flushed in accordance
with Building Regulations L1A/L1B & BS 7593.
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
Fig.1
Fig.2
Fig.3
Manual Handling
When lifting take suitable safety precautions: keep your back straight, bend knees, do not turn your
body, avoid bending forward or sideways and keep the load as close as possible to your body. Ideally
seek assistance in lifting the boiler.
If possible, use a trolley or other suitable means to carry the boiler to site. Use appropriate
protective clothing and gloves to avoid injury from any sharp edges etc.
------------------------------------------------------------------------------------------------------------------------------------ REMOVING THE EXISTING MAXIMA 35C
1. Remove the front panel by undoing the
two case securing screws (A) on the
underside of the boiler. Ease the lower
edge of the front panel forward (B) to clear
the controls facia and lift the panel
upwards off the retaining lugs (Fig.1)
2. Safely isolate the electricity, gas and water
supplies to the appliance. Completely drain
the boiler and central heating system and
disconnect all existing pipe-work
connections from the underside of the
boiler (Fig.2)
3. Disconnect the electrical supply to the
boiler at the 3 pin plug or fused spur.
Remove the securing screws (❷) and
lower the controls facia panel (❸) (Fig.3)
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
4. Undo the securing screw and remove the cover
(❹) to access the terminal block at the right
hand side of the control facia. Disconnect the
mains electrical supply lead and any external
controls connections at the terminal block.
(Fig.4)
Fig.4
5. Disconnect and remove the flue from the existing boiler by
undoing the four screws securing the appliance bend to the top
of the boiler (Fig.5)
Fig.6
6. Ensure that all pipe connections are free, move the
base of the boiler forward and lift the boiler off the
hanging bracket tabs and unscrew the hanging bracket
from the wall. (Fig.6)
7. Finally, check that the wall surface is sound, flat and capable of supporting the weight of the
boiler. Make any necessary repairs before installing the new boiler.
Fig.5
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
Boiler Pack Contents
8. It is suggested that where possible the existing pipe-work is cut back approximately 200mm - 300mm for ease of connecting the existing pipe-work to the new valves (Fig 7)
If a stand-off bracket has been used and the pipe-work runs behind the boiler, then a new stand-off bracket will need to be fitted and pipes extended to the new valve positions (see below; paragraph 3-Fig.5)
INSTALLING THE NEW MODENA C HE 1. Check the existing flue terminal position
with regard to possible nuisance “pluming”. A plume displacement kit is available to overcome any such problems.
2. Unpack the boiler and check the contents are complete and undamaged (see opposite)
Please note: The new flue kit is sold separately
3. Align the fixing template on the wall with
the existing flue hole, ensuring it is level both horizontally and vertically. Check for required minimum clearances then mark the most suitable fixing points for the hanging bracket. It is advisable to mark the position of the gas, water and heating pipes at this point (Fig.5)
4. Drill the wall and fix the hanging bracket
using the wall plugs and fixings provided. Make sure the bracket is level before tightening the fixing screws
1 x Modena C HE Boiler
1 x Installation Instructions
1 x Hanging Bracket
1 x Filling Loop
1 x Valve Pack
1 x Condensate Bowl/Hose
1 x Paper Template
Fig.5
Cut existing pipes back
approx 200mm – 300mm
Fig.7
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
Fig.6
5. Lay the boiler on its back. Remove the front casingpanel by undoing the two securing screws on theunderside of the case. Ease the lower edge of thepanel forward to clear the controls display and liftupwards off the frame.
6. Lift the boiler onto the hanging bracket making sure
the lugs on the bracket locate correctly with the two
support brackets on the boiler frame (Fig. 6)
FOR STANDARD HORIZONTAL TELESCOPIC FLUE INSTALLATIONS
UNPACK THE NEW TELESCOPIC FLUE KIT: CODE - 041049G0
7. Remove the protective adhesive cover from the top of the boiler to expose the flue/fixing holes.Secure the new appliance flue bend to the top of the boiler using the screws and gasket provided
8. Level
8. From the outside, push the flueterminal length through theexisting hole in the building fabricand align with the appliance bend.Lubricate the seal with a suitablesilicone grease and push the fluepipe fully into the into theappliance bend. Ensure the flueterminal is fitted level.
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
9. Remove the condensate bowl and hose fromthe boiler fittings pack. Undo plastic nut (Fig.9-A) and fit the condensate bowl and washer.Push on the rubber condensate hose to the trap outlet (Fig.9-B).
10. Connect the safety valve outlet (Fig.9-C) tothe existing 15mm discharge pipe and thenconnect the existing condensate pipe to therubber hose outlet. Check that both terminatein accordance with – BS 6798. Take care notto interfere with the new routes for gas,water and heating pipe connections
11. Fit the valve kit to the connections on theunderside of the boiler using the washersprovided (Fig 10) and reconnect to the existingpipe-work.
12. Connect the temporary filling loop betweenthe cold water inlet and the C H return pipeas close to the boiler as is practical (Fig.11).Open the CH isolation valves; fill and ventthe system and flush using a commissioningcleanser. During final filling add a suitablecorrosion inhibitor as per BS 7593. Check forleaksREMOVE AND RETAIN THE TEMPORARY FLEXIBLE CONNECTION OF THE FILLING LOOP AND FIT THE CAPS SUPPLIED
A CH FLOW B HOT WATER OUTLET C GAS D COLD WATER INLET F CH RETURN
Fig 10
Fig.9
A B C
Condensate bowl,
washer and rubber
hose connection
Fig.11
CH HW GAS COLD CH
FLOW OUTLET WATER RETURN
Temporary filling
loop between
cold inlet &
heating return
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
13. Open the cold water isolation valve and thoroughly flush the cold/hot water pipe-work byopening all the hot taps.
14. Reinstate the gas supply, purge and test in accordance with BS 6891 and IGE/UP/1.
15. Connect the boiler to the electrical supply;the boiler is provided with a 1m cable andplug. Reconnect any external controls tothe volt free terminal block in the boiler.To access the connections remove thesecuring screw and hinge the controlscover to the left. Connect the externalcontrols to terminal block (72) as shown inFig. 12.
Grommets to accept wiring from external controls are found on the right underside of the boiler.
Please note:
All electrical work must be in accordance with IEE Wiring Regulations - BS 7671:
External controls need to be compliant with Building Regulations L1A/L1B; further information is available from the “Domestic Building Services Compliance Guide”
Fig.12
BOILER REPLACEMENT: MAXIMA 35C TO MODENA 32C HE
Fig.13
Fig.14
Fig. 15
Sample points: 1 = Air / 2 = Flue Gas
16. Commissioning the boiler:
(see 3.3 of the Modena C HE Installation Instructions)
Connect a manometer to the inlet test point of the gas valve (Fig.13)
Set the boiler to operate at maximum by selecting ‘TEST MODE’ and check that the operational (working) pressure at the gas inlet pressure test point is 20 mbar. To enter and exit ‘TEST MODE’, press the CH + & - buttons simultaneously for 5 seconds (Fig.14)
A pressure of 20 mbar should be obtained with all other gas appliances operating.
Please note: there may be a pressure loss across the isolation valve to the gas valve inlet test point of up to 1.3 mbar at maximum.
Remove the manometer & re-tighten the inlet test point.
17. Measure the gas rate of the boiler and check against thefollowing table;
18. Connect the flue gas analyser to the flue sample point(Fig.15); with the boiler still in TEST MODE check that thereadings are within the tolerances set out in the tablebelow;
If the readings are satisfactory, replace the boiler front cover.
Test the correct operation of the boiler, central heating system and DHW.
Advise the customer on the operation of the new boiler and any new controls.
Complete the “Benchmark Log Book
ferroli
Ferroli Limited
Lichfield Road
Branston Industrial
Estate Burton on Trent
DE14 3HD
www.ferroli.co.uk
Boiler replacement
Calls to the above numbers are charged at national rate from BT landlines. Calls from mobile networks may be considerably more.Whilst every effort is taken to ensure the accuracy of the information contained within the brochure, the details are offered in good faith and Ferroli Ltd. accepts no liability for matters arising as a result of errors and/or omissions. The information in this brochure was correct at the time of printing, however specifications and designs may be changed owing to Ferroli’s policy of continuous product research and development. The technical specifications in the product instruction manual supersedes and should always be referred to during installation and maintenance. Reproduction of this publication, or any part, is not permitted without the written consent of Ferroli Ltd at marketing@ferroli.co.uk. The statutory rights of the consumer are not affected.
CONTACT US IN THE UK
SALES 0843 479 4790sales@ferroli.co.uk
SERVICE AND TECHNICAL 0843 479 0479 service@ferroli.co.uktechnical@ferroli.co.ukGENERAL ENQUIRIES
0843 479 0009 generalenquiries@ferroli.co.uk
TWITTERtwitter.com/ferroliuk
Training Well trained installers are the key to a safe and efficient heating system. We offer a choice of training and product awareness courses on our key product range, including the Modena HE, at Ferroli’s fully equipped training centre in Burton-upon-Trent and at specialist training locations across the UK. Courses are aimed at engineers of all levels to ensure that everyone comes away with the skills and knowledge needed to deliver the first class service that customers expect and deserve. For more details visit www.ferroli.co.uk/training or ring 0843 479 0009.
Ferroli Domestic Boilers Offering gas wall mounted units with outputs of up to 50kW, Ferroli’s stylish, compact domestic boilers provide maximum comfort with minimal fuel usage. With a choice of conventional, condensing and combi technologies, there’s a boiler to match the heating and hot water requirements of every home.
Ferroli Commercial and Industrial Boilers Ferroli commercial boilers for pressure jet oil, forced air gas or dual fuel are factory matched with high efficiency burners to provide outputs of up to 12,350kW, whilst meeting the strictest emissions demands.
Ferroli Spares The popularity of Ferroli as first choice for both domestic and commercial installations means that heating parts stockists offer readily available spares for Ferroli boilers. Ferroli has a UK-based fully stocked warehouse enabling same-day despatch of just about any part needed to keep your Ferroli boiler running.
Maxima 35C- Modena HE
top related