mansur he marcela cedeÑo rainwater harvesting system … · rainwater harvesting system. apsc 101...

Post on 04-Jul-2020

0 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

MANSUR HE

MARCELA CEDEÑO

JAYG DIMAYACYAC

HAILY GADA

LIAM HILDER

CHRISTOPHER TONG

Photo source: textureX.com

APSC 101 CAPSTONE

RAINWATER HARVESTING SYSTEM

APSC 101 T2

1• Solutions

2• Alternative Designs

3• Justifications

4• Recommendations

42 m3 STORAGE TANK

HOUSE

LAYOUT A

FULL ROOF +

ADDITIONAL 150m2

APSC 101 T2

LAYOUT A

10m3 COLLECTION TANK

PIPINGS

6 SW-80

SOLAR PANELS

1 BATTERY

AC INVERTER

APSC 101 T2

LAYOUT A

ALL FILTERS

50W UV SYSTEM

PUMP A

APSC 101 T2

LAYOUT B STORAGE TANK

APSC 101 T2

Additional Height

Increased Potential Pressure

Increased Piping

Increased Pressure Loss

• Catchment on top

• No pump required

• No collection tank required

• No roof collection area

• More expensive collection area

• Purely relies on gravity

APSC 101 T2

LAYOUT C

STORAGE TANK

CATCHMENT

APSC 101 T2

20%

25%10%

15%

15% Consumption

Relative Cost

Environmental

Maintenance Occurance

On Demand Flowrate

Reliability

STUDY PROBLEM

SATISFACTION WEIGHTS

APSC 101 T2

STUDY PROBLEM IDENTIFY SOLUTION

Used excel to find solutions with

the best satisfaction

Used real testing and prototyping

via experiments

APSC 101 T2

STUDY PROBLEM IDENTIFY SOLUTION TEST & IMPLEMENT

Consumption, 97.8%

Relative Cost, 89.6%

Environmental, 100.0%

Maintenance Occurance, 97.5%

On Demand Flowrate, 98.9%

Reliability, 99.7%

0.0%

25.0%

50.0%

75.0%

100.0%

APSC 101 T2

SATISFACTION

APSC 101 T2

82m PIPING12m PIPING

X: 10

Y: 5

Z: 5

X: 76

Y: 12

Z: 27Layout A Layout B

Smaller pressure

lost due to

piping

More pressure

lost due to

piping

APSC 101 T2

WATER CONSUMPTION

88%

96%

94%

82%

84%

86%

88%

90%

92%

94%

96%

98%

0%

5%

10%

15%

20%

25%

400L 580L 625L

Consumption Cost Reliability Overall

COLLECTION AREALayout A

• Uses roof and additional area

• Small area

• Less expensive

Layout C

• Only additional area

• Located higher

• Farther – more pressure loss

• More Expensive

APSC 101 T2

APSC 101 T2

250m2 TOTAL COLLECTION AREA

100m2 whole roof150m2 additional area

APSC 101 T2

COLLECTION AND STORAGE TANK

35000L10000L

CATCHMENT TANK

• Options in fixed increments, must satisfy volume

• Must be greater than consumption to prevent overflow and satisfy needs

• Defines maximum Q in for the system of days

APSC 101 T2

10000L$2,000

Storage Tank

• Pay per unit of volume, remainder from Total

Tank Size

• Cost the minimum possible in order to maintain

water in system during low rainfall periods

APSC 101 T2

STORAGE TANK

35000L$10,500

NO TOWERS

APSC 101 T2

$96,372

$55,698

Total expense with identical parameters

+$40,674

APSC 101 T2

PUMP CHOICE

A B C

APSC 101 T2

0.00

50.00

100.00

150.00

200.00

250.00

300.00

350.00

400.00

450.00

0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00

Flowrate [LPM]

Pressure [kPa]

37 LPM

126 kPa

System

Pump A

Pump B

Pump C

APSC 101 T2

$580.00

$1,400.00

$3,500.00

Pump A Pump B Pump C

Cost of pump per replacement

APSC 101 T2

FILTERS

200µm Bag Filter 5µm Bag Filter 1µm Bag Filter

APSC 101 T2

199

138

59

Only 1 Only 1 and 200 All

Maintenances

90%

94%

96%

Only 1 Only 1 and 200 All

Satisfaction

$14,925

$8,875

$10,900

Only 1 Only 1 and 200 All

Replacement Cost

APSC 101 T2

FILTER DIRECTION

• Highest flow rate – 35 LPM

• Does not limit on-demand flowrate

• Placed downstream

• Same replacement time compared to 36W

• More expensive

• Increased energy usage

UV DISINFECTION SYSTEM

50W

Energy Required by System

• Energy to pump and filter water

• Energy to convert current from DC to AC (Inverter)

• Divided out by energy inefficiencies

Calculating Power Out

- Pump Power: Dependent on Water collected in Catchment Tank

- Inverter: Runs with Pump

- UV: Constant Power of 4500 kJ/day

Total Electrical Energy Used:

4500 kJ/day < Energy < 5400 kJ/day

Calculating Power In

Six Solar Panels :

5400 kJ/day

One Battery :

7200 kJ/day

APSC 101 T2

ON DEMAND FLOW RATE

• Still has high satisfaction (99%)

• More expensive method required for 30 LPM

29 LPM 30 LPM

Cannot be satisfied using

selected location

EXPENSES (5 YEARS)

APSC 101 T2

Initial Cost,

$36,973.00

Water Import Costs,

$4,125.00

Replacements,

$14,425.00

$36,073.00

$50,000.00

$9,825.00

$16,000.00

$9,800.00 $12,495.00

Layout A Layout B

Initial Costs Water Import Costs Replacements

$55,700 $78,500

Replacement

Costs

• Filter – 75 Times/5

Years

• Pump not expected to

be replaced

Days Without

Service• $75 per day to ship

water

• 55 Days without water

Expense Total Cost

Water Import $4 125

FINAL RECOMMENDATION

1 LEAD ACID BATTERY

50W UV DISINFECTION SYSTEM

APSC 101 T2

FULL ROOF + 250m2

ADDITIONAL RAINWATER

COLLECTION AREA

10000L RAIN WATER

COLLECTION TANK

35000L STORAGE TANK

LOCATED AT X = 10, Y = 5

PUMP A

ALL FILTERS APPLIED

Collection to storage

6 SW-80 SOLAR PANELS

DC TO AC INVERTER REQUIRED

FOR COMPONENT OPERATIONS

DAILY CONSUMPTION OF 580L

AND ON DEMAND FLOWRATE OF

29 LPM

APSC 101 T2

CONCLUSION