m40, a versatile multi-gas monitor capable of
Post on 21-Jul-2022
1 Views
Preview:
TRANSCRIPT
Industrial Scientifi c is pleased to offer the M40, a versatile multi-gas monitor capable of detecting CO, H2S, O2, and combustible gases
for a wide variety of hazardous and confi ned space applications.
The M40 is housed in a rugged, impact-resistant case to provide superior performance and durability in harsh environments and resistance to radio-frequency and electromagnetic interference. Its four-button interface provides simple, intuitive operation and calibration, and the M40’s fi ve-second “Off” feature prevents unintentional shut-offs. The unit’s compact size and economical price make it an ideal personal monitoring instrument.
Other standard features include a vibrating alarm, lithium-ion battery, peak/hold readings, large LCD, 75 hour datalogging capacity, and belt clip. An optional compact parasitic sampling pump enables remote sampling from up to 50 feet away. The M40 carries a two-year warranty.
● 1 to 4 gas monitoring for O2, H2S, CO & combustible gases● 18-hour runtime with lithium-ion battery● Includes vibrating, 90 dB audible, and LED visual alarms● Two-year, all inclusive warranty
SPECIFICATIONS
Monitor shown actual size
CASE: High-visibility, impact resistant composite – RFI, EMI and ingress protection tested and approved
DIMENSIONS: 4.30"h x 2.45"w x 1.37"d (10.9cm x 6.22cm x 3.48cm)
WEIGHT: 8.6 ounces (244 g) Weight with pump: 11.6 ounces (326 g)
SENSORS: The M40 is available in a 1, 2, 3, or 4-gas configuration including oxygen, hydrogen sulfide, carbon monoxide and combustibles /hydrocarbons.
MEASURING RANGES: CO range: 0-999 ppm in 1 ppm increments H2S range: 0-500 ppm in 1 ppm increments O2 range: 0-30% volume in 0.1% increments Combustibles: 0-100% LEL in 1% increments The M40 features LEL over-range protection
POWER SOURCE: Rechargeable lithium-ion integral battery
RUNTIME: 18 hour – instrument (non-alarm) 12 hour – instrument with pump (non-alarm)
DISPLAY: Large LCD provides simultaneous and continuous readout of up to all four gases. Large, high-contrast characters, graphic icons and unique amber backlight provide clear display visibility in low-light conditions.
ALARMS: Vibrating, 90 dB audible and ultra-bright LED visual alarms. High/low, STEL, TWA and low battery alarms. Flow alarm indicator when used with optional SP40 pump.
DATALOGGING: Up to 75 hours of datalogging capability
TEMPERATURE RANGE: -4º to 122ºF (-20º to 50ºC)
HUMIDITY RANGE: 15 to 95% RH, typical, 0 to 99% RH intermittent (non-condensing)
IP RATING: IP65
APPROVALS: UL – Class I, Div. I, Groups A, B, C, D; T4 CSA – Class I, Div. I, Groups A, B, C, D; T4 Cenelec (ATEX) – EEx ia d IIC T4 Australia – Ex ia s Zone 0 IIC T4
1001 Oakdale Road, Oakdale, PA 15071-1500(412) 788-4353 Toll Free: 1-800-DETECTS Fax: (412) 788-8353 www.indsci.com e-mail: info@indsci.com
Industrial Scientifi c is an Equal Opportunity Employer.
REV1205
1001 Oakdale Road, Oakdale, PA 15071-1500(412) 788-4353 Toll Free: 1-800-DETECTS Fax: (412) 788-8353 www.indsci.com e-mail: info@indsci.com
Industrial Scientifi c is an Equal Opportunity Employer.
M40 COMMON CONFIGURATIONS AND OPTIONAL ACCESSORIES
REV1205
PART NUMBER DESCRIPTION 18105437-01111* M40 – Four gas confi guration for O2, LEL, CO, H2S 18105437-01110* M40 – Three gas confi guration for O2, LEL, H2S 18105437-01101* M40 – Three gas confi guration for O2, LEL, CO 18105437-00110* M40 – Two gas confi guration for H2S, LEL 18105437-01100* M40 – Two gas confi guration for O2, LEL 18105437-00100* M40 – Combustible gas confi guration for LEL only 18105437-11111+ M40 and Pump Combination for O2, LEL, CO, H2S 18105437-11110+ M40 and Pump Combination for O2, LEL, H2S 18105437-11101+ M40 and Pump Combination for O2, LEL, CO 18105437-11100+ M40 and Pump Combination for O2, LEL 18105437-10100+ M40 and Pump Combination for LEL M40-KIT-11111** M40 Confi ned Space Kit (with Pump) – O2, LEL, CO, H2S M40-KIT-11101** M40 Confi ned Space Kit (with Pump) – O2, LEL, CO M40-KIT-11110** M40 Confi ned Space Kit (with Pump) – O2, LEL, H2S 18105973-ABX++ M•Cal406™ – Six-Unit Calibration Station 18105965-10X++ M•Cal401™ – Single-Unit Calibration Station (with M40 Bay) 18105965-01X++ M•Cal401™ – Single-Unit Calibration Station (with M40/SP40 Bay) 18105460 SP40 Sampling Pump 18105528 M40 Datalink 18105478 M40 Nylon Carrying Case 18105486 M40/SP40 Combination Carrying Case 18105494 Compact Charger 120 VAC 18105668 Compact Charger 230 VAC 18105890 UK Compact Charger 230 VAC 18105908 AUS Compact Charger 230 VAC 18105502 12 VDC Automotive Charger 18105510 Six-Unit Charger 17092941 Metal Belt Clip 17107582 Suspender Clip ++M•Cal™ Calibration Station Ordering Information – A = # of M40 Bays (0-6), B = # of M40/SP40 Bays (0-6), X = Power Cord (0 = N. Amer., 1 = U.K., 2 = Eur, 3 = AUS)
**All confined space kit combinations include:■ compact charger ■ calibration cup■ tubing■ utility case■ gas cylinder■ cell-phone style belt clip■ suspender clip ■ regulator valve■ water barrier assembly■ filter■ instruction manual■ combo monitor/pump
leather carrying case
+All monitor/pump combinations include:■ compact charger ■ calibration cup■ tubing■ cell-phone style belt clip ■ suspender clip■ instruction manual■ combo monitor/pump
leather carrying case
*All monitors include:■ compact charger ■ calibration cup■ tubing■ leather carrying case■ cell-phone style belt clip■ suspender clip ■ instruction manual
M40 Multi-Gas Monitor shown withoptional SP40 Sampling Pump attached
Optional M•Cal401 Calibration Station shown with M40/SP40 Bay
R22
R404a
H2
R717
(NH3)
R134a
testo 316-4
Committing to the future
Leakage Detector for RefrigerantsFast and reliable detection of leakages in refrigeration systems and heat pumps NEW!
High-quality leakage detection instrument for refrigerants, with an extremelylong sensor life
testo 3316-44 SSet 11 tthe ffast aand rreliable lleakage ddetector ffor aall
common rrefrigerants
testo 3316-44 SSet 22 sspecially ffor aammonia.
The sensor is permanently monitored and shows malfunctions or
contamination in the display. The use of test leaks is thus no longer
necessary. If dirty, the sensor can be easily cleaned and is
immediately ready for use again.
When leaks are detected, the display changes from green to red. An
audible signal additionally informs of leakages detected. Using the
earplug, the testo 316 can also be used in loud surroundings. The
maximum indicator function shows maximum leakages and so
facilitates the identification of leakage locations. The flexible
gooseneck allows the optimum positioning of the sensor close to the
piping or the leakage location.
A simple change of sensor by the user turns the 316-4 into an
ammonia detector.
Advantages:
• Very long sensor life
• Optical and audible alarm
• Permanent sensor check
• Easy sensor change by the user
• Earplug socket for secure localization of leakages in loud
surroundings
Qty. Item
Set 1 consisting of testo 316-4, sensor head refr. (CFC, HCFC, HFC, H2), case, mains charging unit, earplug)
Set 2 consisting of testo 316-4, sensor head NH3, case, mains charger unit, earplug
Replacement sensor for leakage tester: refrigerants (CFC, HCFC, HFC, H2)
Replacement sensor for leakage tester: ammonia (NH3)
Part no.
0563 3164
0563 3165
0554 3180
0554 3181
Fax Order Form
Name
Company
Telephone/Fax
Department
Address
City
Date, Signature
Sender
0981
573
4/m
sp/A
C/A
/01.
2007
Sub
ject
to c
hang
e w
ithou
t not
ice.
Easy sensor change by the user
Permanent sensor check
Maximum indicator showsmaximum leakages
Meas. parameter g/a
Technical data
Detectable R134a, R22,R404a, H2 and allcommonrefrigerants such asCFC, HCFC, HFCNH3 (separatesensor head)
Dimensions 190 x 57 x 42 mm
Weight 348 g
Oper. temp. -20 to +50 °C
Oper. humidity 20 to 80 %RH
Storage temp. -25 to +70 °C
Reaction time <1 s
Certified - SAEJ1627
Leakage alarm
Complies with:
Long gooseneck 370 mm
Power supply 1 battery block (6cells NiMh)
Battery life 6 h (Continuousoperation)
Warranty
1g/year sensitivityacc.to EN 14624and E 35-422
24 months(instrument andsensor)
Start-up time <50 s(0 to +50 °C)<80 s(-20 to 0 °C)
lower reactionthreshold
3 g/a
optical and audiblealarm
Technical data
Detects spillage in burners quickly and efficiently
Dimensions 128x46x18 mm
Battery type 3 AAA micro batteries
Display Optical/Audible
Warranty 2 years
Measuring medium Ambient air
Reaction time 2 s
Length/Probe stem
Length/Probe stemtip
Diameter/Probestem tip
200 mm
35 mm
Ø 10 mm
The testo 317-1 quickly and efficientlydetects escaping flue gases at the source.Flue gas escaping from a burner is causedby equipment failure and is an indicator ofCO in the living space, an audible andoptical alarm is triggered.
The electronic humidity detector
Flexible probe for hard-to-accesslocations
Visual and audible alarm signals
Technical data Ordering data for Accessories
Checks for leaks in domestic gas pipelines
104
1st alarm limit: from 200 ppm CH4
2nd alarm limit: 10,000 ppm CH4
Gas pipes can develop leaks resulting in arisk of explosion. The practical and robusttesto 316-1 gas leak detector quickly detectseven the smallest leaks.
TopSafe (indestructible protection case) withbench stand Protects instrument from dirt and impact
0516 0189Part no.
Gas leak detector
Electronic flue gas spillage detector
Flexible probe
Flexible probe
Case for instrument and probesFor safe and orderly storage
0516 0182Part no.
Transport case (plastic) For transport and secure storage of measuringinstrument and accessories
0516 3120Part no.
Accessories set (for instrument without TopSafe)includes multi-function clip, carrier loop, probeholder
0554 0550Part no.
Flexible measurement probe forhard to reach locations
Optical and audible alarms signalwhen limits are exceeded
TopSafe case protects from dirtand impact (optional)
Part no.
testo 316-1, electronic gas leak detector withflexible probe, battery included
0632 0316
testo 316-1
Part no.
teto 317-1, electronic flue gas spillage detectorwith flexible probe, incl. battery
0632 3170
testo 317-1
testo 312-2, the DVGW approved pressure gauge for gas systems, is the ideal partner instrument. See Chapter on pressure
We recommend testo 315 for servicing gas heating systems, see from next page
Probe type
Meas. range
Semiconductor probe
0... +10000 ppm CH4
Dimensions
Weight
190x57x42 mm
300 g
Battery type
Battery life
9V block battery
5 h
Material/Housing ABS
Warranty 2 years
DVGW approval
ppmCH4
°C td
GB_104.qxd 14.02.03 07:27 Sei e 1
Additional information at 5
Gas leak detectortesto 317-2
Highly practical gas leak detectorfor fast checks on gas pipeconnections, with visual bardisplay.
Ambient carbon monoxide warningtesto 317-3
The testo 317-3 CO monitordetects the presence of carbonmonoxide in the surrounding areaand warns the user both visuallyand audibly about dangerous gasconcentrations e.g. wheninstalling and servicing gasheaters.
Part no.
0632 3173
testo 317-3, testo 317-3 CO monitorincl. leather bag, headphones, wriststrap, self-test function, sampler
www.testo.comwww.testo.com
Meas. range 0 to +1999 ppmAccuracy±1 digit
±10 ppm (0 to +99 ppm)±10 % (+100 to +499ppm)±20 % ( >+500 ppm)
Resolution 1 ppm
Oper. temp. -5 to +45°C
Battery life 150 h (with beeperswitched off)
Warranty 2 years on the instrument3 years on the CO sensor
Battery type 2 batteries Type AAA
Technical data
Reaction time 40 s
Meas. rangeTechnical data
Part no.
0632 3172
testo 317-2, Gas leak detectorincluding case with belt clip andwrist strap, self-test function andbatteries
Shows gas concentration in visual bardisplay
Sensor self-test following switch-on
Audible confirmation of readiness tooperate
Increasing alarm sounds withincreasing gas concentration
Continuous sound if alarm thresholdis exceeded
Battery monitoring with optical display
0 to 20.000 ppm CH40 to 10.000 C3H8
Display 8 segment trend display
Alarm thresholds 10.000 ppm CH45000 C3H8
Lower responsethresholds
100 ppm CH450 C3H8
<5 s
Battery type 2 batteries type microAAA 1.5 V (LR03)
t90Heat-up time
Oper. temp. -5 to +45 °CStorage temp. -20 to +50 °CAudible emitter 85 dB(A)
Battery life 4 h (LR03)
60 s
3 year warranty on CO sensor
Visual and audible alarm
No zero phase, instrument can beused immediately
Adjustable alarm threshold
CO zeroing at site
JL269 Serials Gas Leakage DetectorJL269 Serials Gas Leakage Detector
top related