lynx-thermal 1x50 · 2018. 5. 8. · thermal vision attachment “lynx-thermal 1x50” 1 pc....
Post on 30-Oct-2020
4 Views
Preview:
TRANSCRIPT
Lynx-Thermal 1x50thermal vision attachment(clip-on) for daylight optics
EN
OPERATOR’S MANUAL
www.dipol.biz
СОntent :1. Package …….……………………………………………….……..............….. 32. Precautions…………………………………………………….................…. 33. Purpose ……………………………………………………………….…………… 34. Technical characteristics ………………………..……………….…...….. 45. Design and device ………………………………………………..….…...…. 56. Setting-up procedures and performance inspection ………… 67. Device operations ................................................................ 68. Use of additional accessories …………………………………….….…. 89. Possible defects ……………………………………………………….………. 810. Storage and transportation …………………………………….….….. 911. Guarantee………………………………………………………………………. 9
Attention! Before operating read attentively
the present manual!
2
www.dipol.biz
3
1. Package
Thermal vision attachment “Lynx-Thermal 1x50” 1 pc.Transporting softcase 1 pc.Lens cap 1 pc.Lens cleaning cloth 1 pc.Battery (CR123) 2 pc.
2. Precautions
IT IS IMPORTANT!It is strongly forbidden to direct device to the sun and other
sources of intensive thermal radiation temperature of which exceeds 500 С0!
• Protectthedevicefromshock• Don’twipeobjectiveandeyepiecelenseswithhardabrasive
materials. • Don’tstorethedevicewithpowersources.
3. Purpose
The device is intended to observe movable and immovable objects in conditions of various illumination and limited visibility(fog, dust, etc.)
www.dipol.biz
4
Sensor, pixel/ detector pitch 384x288/ 17umFocal length/aperture ratio F50 / 1,0Multiplicity, X 1хAngleofview,degr 7,5°х5,6°Detectionrange(object0.5x1.8m),m up to 1200Spectral range, micrometer 8-14Frequency, Hz 50
Polarity Hot black / Hot white/colored
Microdisplay, pixels OLED 1024x768Diopteradjustment,diopters ±4Eye relief, mm 22Max. impact load, g 600
Voltage/Battery type 6V / 2 x CR123A Lithium
Operating time (+20°C), hours 2,5Operationtemperaturerange,°С -20 … +50Degree of protection according to IEC 60529 (optional) IPX5 (IPX7)
Dimensions, mm 200x81x81Weight , kg 0,78Plugforexternalpowersupply(12V) presentManualadjustmentofsensorreinforcement presentManualadjustmentofmicrodisplaybrightness present
4. Technical characteristics
www.dipol.biz
5
5. Design and device
1. On/off-switcher2.Objective3.Objectivefocusinghandle4.Brightness/reinforcementadjustmenthandle5. Clamp adapter6. On-indicator7. INVERT Polarity change button8. SAVE button9.Outerpowersourceslot10. Battery compartment cap
1
4
8103
9
7
6
2
7
8
4
1
10
5
www.dipol.biz
6
6. Setting-up procedures and performance inspection
Insertpowerelementsduetopolarityindicatedonthehousingandtakeoff(twistoff)objectivecap.
Turnontheswitcher(1),besurethaton-indicator(6)isredandwaittillan imageappearsondisplay(intheeyepiece).Switch-ontimedoesn’texceed3-5seconds.
Afterthepowerisonyouwillseethemainmenuwithseveralsettings:
Sensor gain level Brightness level
Sensor sensivity Polarity / Palette numberlevel Powersource(battery, accumulator,externalpower)
Thismenuwill automatically disappear from the display after3-5 sec of inactivity. Hereinafter to display the menu, press button SAVE (8) shortly.
7. Device operations
Use of the device for observing. In order to use the device as an independent supervisory device use an magnification booster. You may install it in the clamp adapter (5) or remove the clamp adapter (5).Afteritdirectthedevicetothechosenobjectandreachsharpimageoftheobservedobjectbyrotatingfocusinghandle(3)oftheobjective(2).
Use of the device with day optic devices. To use the device togetherwithdayopticdeviceyoushouldchooseaclampadapter(5)correspondingtotheouterdiameteroftheobjectiveofdayopticdevice.Mountthedevicetotheobjectiveofthedaydevicefirmlyandtightentheclamplever(5).Withthehelpofdiopteradjustmentring of the day device reach maximal possible sharpness of the image. After it direct the device to the chosenobject and reachsharpimageoftheobservedobjectbyrotatingfocusinghandle(3).
www.dipol.biz
7
Color palette changing. Hot black/ hot white palette is usedin the device like basic one. For palette change press and hold INVERT (7) button during 3-5 sec until PLx will be displayed (х - palette number, changed from 1 to 8). Then press the button (7) sequentially for necessary palette change. To save palette change pressSAVEbutton(alsopalletechoosingmodewillcanceled).
Payyourattentionthatthedevicesettingswillnotchangeafterthepowerisoff.
Image polarity. By pressing INVERT (7) button choose necessary imagepolarity:hotblackorhotwhite (forbasic settings). Colorpalettes also have possibility to change polarity. Selected polarity willbedisplayedforamomentondisplaylikeor.
Sensor reinforcement, sensor sensivity, display brightness adjustments. Press handle GAIN (4) shortly. In the center of display youwillseethelastsetting-GNorBRorDEorSN.Toselectthedesired setting press handle (4) shortly again. By rotating the handle (4) choose suitable range.
If you need to adjust the device image relatively to the field of view of the day device. PressSAVE(8)button(theinfotablewillbe displayed), then press and hold on for 3-4 seconds the handle GAIN(4),pressshortagainthehandleGAIN(4),CORRECT1willbedisplayed, after it by rotating the handle GAIN (4) you may move the image right or left from -30 up to +30. Once again press shortly the handle GAIN (4) in order to pass to vertical image motion mode. By rotating the handle GAIN (4) you may move the image up or downfrom-30upto+30.AfterimageadjustmentpressSAVE(8)button to store the chosen image position or press 3-4 seconds handle GAIN (4) to get out of the menu.
www.dipol.biz
Bad pixel correction. Press and hold SAVE (8) button during 3-6 sec to enter to the bad pixel correction mode. The title Bad pixel willbedisplayed,andthentitlelike:
Х Y Save Exitandcrosshairswithflashingpointinthecenter.By rotating the handle GAIN (4) aim the flashing point to the badpixel (to change x-axis to y-axis press (4) button) then press
«SAVE»button(8)andbadpixelwillberestored.Ifyouhaveanotherbadpixel,repeatsteps.Ifyouwanttoleavecorrectionmodepressand hold SAVE (8) button (the title «turn POWER OFF the device» willdisplayed)and turnoff thedeviceorchooseExitmenu itemsequentially press (4) handle then rotate (4) handle (the title «EXIT» andmainmenuwilldisplayforamoment).
Reset settings. To reset settings to basic ones hold handle GAIN (4)+ INVERT (7) button+ SAVE (8) button and turn on the device. Removefingers frombuttonsandhandleaftershowingthe logo.Whenthetitle«PressINVERTtoreset»and5seccountdowndisplaypress INVERT (7) button shortly.
8. Use of the device with additional accessories
There is an opportunity in the device to connect car embedded networkthroughtheslot(10)withthehelpofspecialcableorouterpowersourcewithoutputvoltageof8-14,5VandJACK2.1slot.
9. Possible defects and methods of their removal
Your device is a complex optomechanical device. Its repair and service may be fulfilled only in conditions of manufacturer.
Ifswitch-onindicator(6)doesn’tshineorblinkafterswitching-on the sight, and image is absent or blinks in the eyepiece, so may be powerelementsareunchargedorjunctionsinbatterycompartmentarebroken.Changepowerelements,inspectjunctionatthebatterycompartmentcap(10)andjunctioninsidethebatterycompartment.Thereshouldn’tbeanycorrosiontracesandanydirtying.Ifpowerelements are changed and junction cleaning doesn’t help, if any
8
www.dipol.biz
9
otherdefectsorfailuresappear,don’ttrytodisassemblethedevicebyyourselfandrepairit.Itmayleadtogreaterfailuresandwarrantyloss. Turn to the vendor or to the manufacturer.
10. Storage and transportation
Deviceistobekeptincaseindryheatedandairedroomwithrelativehumidityup to80%with temperature5°С - 30°С. In theroomthereshouldn’tbeanyacidfumes,alkaliandotheraggressivedirtintheair.Evenifthedeviceiskeptforshorttermextractpowerelements from the device.
While preparing the device for long-term storage, you need to dothefollowingthings:
-lubricatewithanygunoiluncoloredmetalparts,lubricatecapthread of battery contact, battery compartment thread, lubricate innercontactofbatterycompartmentwithanyagunoil,dryupthedevice.
Transportation conditions depend on climatic factors (temperature-20upto+50°С,relativehumiditynotmorethan98%at25°С).
Device can be transported by any kind of transport, in roofed vehicles according to transportation rules at the given kind of transport.
11. Guarantee
• Manufacturerguaranteesthatthermalvisiondevicequalitycorresponds to technical demands if storage, transportation and operation rules and conditions are adhered to. • Guaranteeperiodconstitutes24months.
top related