low differential pressure gage
Post on 29-Jun-2022
3 Views
Preview:
TRANSCRIPT
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combinationof Manosys
Accessories
ApplicationCautions for useMaintenance
Manostar Gage WO81 General purpose type Low Differential Pressure GageRoHS compliant
Utility model registrationNo.823971
V Only vertical
H Only upward horizontal
Blank Both vertical and upward horizontal
D Pa
E kPa
Max. value of scale
N Without flag pointer
S With one flag pointer
T With two flag pointers
F Surface installation type
PC Panel installation round type
PR Panel installation square type
F N 50 D V (example)
Installation position
Unit
Range
Flag pointer
Type
Product code
W O 8 1
Pressure range code
◆If you order or ask, please specify the product code and the pressure range code.◆Refer to p.7 for the instrument displayed the air volume and velocity scale.
WO81FN(surface installation type with non flag pointer)
WO81PRS(panel installation square type with one flag pointer)
WO81PCT(panel installation round type with two flag pointers)
・Broad line-up of product
・Supporting the air volume scale and the air velocity scale (refer to p.7)
・Readable wide-angle scale (Angle of the pointer-rocation is 270 °)
・It is easy to convert polarity enable by piping connector
・Even when the pressure becomes excessive, the original mechanism avoid damage to moving parts.
・Small hysteresis is realized by the silicone rubber diaphragm.
・The pointer is not fluctated by the original band-linked mechanism.
WO81FT(surface installation type with two flag pointers)
<Example of main use field>Nuclear facilitiesAir conditioning control system of the food factoriesAir conditioning control system of the high-rise buildingsHospital and medical facilitiesProduction lines of the car and the semi-conductorExhaust gas pressure control of coffee-roaster machines
<Example of use>Measuring the inside pressure of clean roomsDetection of the pressure loss of an air filterMeasuring air volume and velocity in a ventilator and an exhauster.
*(refer to p.93)
3
Low Differential Pressure Gage
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combination of Manosys
Accessories
ApplicationCautions for useMaintenance
Types
Bodies
Flag pointers
Surface installation type Panel installation round type Panel installation square type
F PC PR
Non flag pointer N WO81 F N WO81 PC N WO81 PR N
One flag pointer (red) S WO81 F S WO81 PC S WO81 PR S
Two flag pointers (red and green) T WO81 F T WO81 PC T WO81 PR T
Pressure units
Pressure measuring method
Pressure receiving element
Gas to be measured
Scale indicating angle
Medium and ambient temperature
Ambient humidity
Withstanding pressure of instrument body
Material of outer case
Withstanding impact
Withstanding vibration
Pa, kPa
Measuring differential pressure
Diaphragm
Air or non-corrosive gas (not liquid)
Approximately 270 ° Wide-angle indication
- 10 to + 50 ℃ (no freezing)
90 % RH or less (no dewing)
200 kPa (refer to p.104)
Polycarbonate and polyamide
100 m/s2(each 6 times on triaxial directions)
5 to 10 Hz Amplitude : 10 mm10 to 50 Hz Acceleration : 39 m/s2
(each two hours on triaxial directions)
Applicable piping
Polarity of piping connector
Mass
・Vinyl, plastic or rubber tube (I.D. 6) ...The resinous piping connectors (installed) for vinyl or
plastic tube.・Metal tube (O.D. 6 ± 0.1) ...Metal type piping connector (option) is needed. ・Hard plastic tube (O.D. 6 × I.D. 4) ...Metal type piping connector (option) and Inner sleeve set
(XIN6 × 4) are needed.(refer to p.92)
・The piping connector indicated red color is high pressure side and blue color is low pressure side.
・Enabling to convert the polarity by changing piping connectors of high pressure side for low pressure side.
Approximately 270 g
AccessoriesOne set of screws for installation Two sets of adaptors for installation
(with main body)One set of nuts for installation
(with main body)
WO81F WO81PC WO81PR
Specification
Pressure range codes Pressure rangesStandard installation
positions (refer to p.10)
Accuracies (at 20 ℃ )
Material of pressure receiving element
Withstanding pressures of receiving element
(refer to p.104)
50 DH 0 ~ 50 Pa
Upward horizontal (fixed) ± 5 % FS
Silicone rubber
10 kPa
50 DV Vertical (fixed)
100 DH 0 ~ 100 Pa
Upward horizontal (fixed)
± 2.5 % FS 100 DV Vertical (fixed)
200 D 0 ~ 200 Pa
Installation position from upward horizontal to vertical
is available.
300 D
500 D
1000 D
0 ~ 300 Pa
0 ~ 500 Pa
0 ~ 1000 Pa
± 1.5 % FS
40 kPa 2 E
3 E
5 E
0 ~ 2 kPa
0 ~ 3 kPa
0 ~ 5 kPa
10 E
20 E
30 E
50 E
100 E
0 ~ 10 kPa
0 ~ 20 kPa
0 ~ 30 kPa
0 ~ 50 kPa
0 ~ 100 kPa
150 kPa
+- 50 DH - 50 ~ + 50 Pa
Upward horizontal (fixed)
± 2.5 % FS 10 kPa +- 50 DV Vertical (fixed)
+- 100 D - 100 ~ + 100 Pa
Installation position from upward horizontal to vertical
is available.
+- 200 D
+- 300 D
+- 500 D
+-1000 D
- 200 ~ + 200 Pa
- 300 ~ + 300 Pa
- 500 ~ + 500 Pa
-1000 ~ +1000 Pa ± 1.5 % FS 40 kPa
+- 2 E
+- 3 E
- 2 ~ + 2 kPa
- 3 ~ + 3 kPa
4
WO81
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combinationof Manosys
Accessories
ApplicationCautions for useMaintenance
Scale table of Manostar Gage WO81 modelSingle pressure range
◆It is charged to print + or - sign on scale plate.
Actual size
Installation position Pressure range Min. scaleHorizontal 0 ~ 50 Pa 0.5 PaVertical 0 ~ 50 Pa 0.5 Pa
Installation position Pressure range Min. scaleHorizontal 0 ~ 100 Pa 1 PaVertical 0 ~ 100 Pa 1 Pa
0 ~ 1000 Pa 10 Pa
Pressure range Min. scale0 ~ 2 kPa 0.02 kPa0 ~ 20 kPa 0.2 kPa
Pressure range Min. scale0 ~ 3 kPa 0.02 kPa0 ~ 30 kPa 0.2 kPa
Pressure range Min. scale0 ~ 5 kPa 0.05 kPa0 ~ 50 kPa 0.5 kPa
Pressure range Min. scale0 ~ 10 kPa 0.1 kPa0 ~ 100 kPa 1 kPa
Pressure range Min. scale0 ~ 300 Pa 2 Pa
Pressure range Min. scale0 ~ 500 Pa 5 Pa
Pressure range Min. scale0 ~ 200 Pa 2 Pa
5
Low Differential Pressure Gage
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combination of Manosys
Accessories
ApplicationCautions for useMaintenance
Zero point center range
Installation position Pressure range Min. scaleHorizontal -50~+50 Pa 1 PaVertical -50~+50 Pa 1 Pa
Pressure range Min. scale-200~+200 Pa 5 Pa
Pressure range Min. scale-3~+3 kPa 0.05 kPa
Actual size
Pressure range Min. scale-500~+500 Pa 10 Pa
Pressure range Min. scale-100~+100 Pa 2 Pa-1000~+1000 Pa 20 Pa
Pressure range Min. scale-300~+300 Pa 5 Pa
Pressure range Min. scale-2~+2 kPa 0.05 kPa
6
WO81
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combinationof Manosys
Accessories
ApplicationCautions for useMaintenance
V Only vertical
H Only upward horizontal
Blank Both vertical and upward horizontal
DM Pa (dynamic pressure Pa)
EM kPa (dynamic pressure kPa)
Max. value of scale
N without flag pointer
S With one flag pointer
T With two flag pointers
F Surface installation type
PC Panel installation round type
PR panel installation square type
F N 49 DM V (example)
Installation position
Unit
Range
Flag pointer
Type
Product code
W O 8 1
Pressure range code
◆If you order or ask, please specify the product code and the pressure range code.
Air volume Air velocity
m3/h
m3/h×10
m3/h×1000
m3/h×10000
m3/h(nor)
m3/h(nor)×10
m3/h(nor)×1000
m3/h(nor)×10000
m3/min
m3/min×10
m3/min×1000
m3/min×10000
m3/min(nor)
m3/min(nor)×10
m3/min(nor)×1000
m3/min(nor)×10000
m / s
Data sheet for calculating air volume or velocity.(Please inform us data sheet ① or ② for calculating air volume or velocity. Base on data sheet, we issue you specification of air volume or velocity scale.)To make out the specification based on gas condition (temp, humidity, static pressure, density), size of the duct and medium flow rate. →①To make out the scale specification based on the relationship between air volume (or velocity) and dynamic pressure.(If the detector is a orifice and so on.) →②
For calculating air volume
or velocity ①
Gas to be measured data
Working regular air volume (velocity) value
Max. air volume (velocity) value
Duct size
In case of mixed gas, please specify the density of mixed gas.
Used pressuredetector
I.D. ( ) mm or square duct ( ) mm ×( ) mm
Gas temperature Gas density
Gas humidity Static pressure at the point to be measured
℃
% RH
Pa
Please f i l l in the va lue o f the point to be measured to installing the pressure detector.
kg/m3
* Air density is 1,200 kg/m3 at normal state.
For calculating airvolume or velocity ②
Using condition value is at
is measured till ( )
When air volume (velocity)
Max. air volume (velocity)
dynamic pressure Pa
◆If you order the air volume and velocity meter, please tell us the data for calculating air volume and velocity.◆The max. value of air volume and velocity is rounding off to our printing scale.◆The max. pressure value correspond to the max. value of air volume (velocity) is written in scale plate.
WO81FN(surface installation type with non flag pointer)
Display unit
Manostar Gage WO81 General purpose type Air volume and velocity meters
This and next page is introduction pages for air volume and velocity meter of WO81.Refer to p.3, p.4 for low differenctial pressure gage of WO81.
Total static pressure tube (Pitot tube)
Total pressure tube + Static puressure tube
Multi-pitot tube(corrected air volume coefficient)
7
Low Differential Pressure Gage
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combination of Manosys
Accessories
ApplicationCautions for useMaintenance
Air volume or velocity range(example scale)
Actual size
Types
BodiesFlag pointers
Surface installation type Panel installation round type Panel installation square typeF PC PR
Non flag pointer N WO81 F N WO81 PC N WO81 PR NOne flag pointer (red) S WO81 F S WO81 PC S WO81 PR STwo flag pointers (red and green) T WO81 F T WO81 PC T WO81 PR T
units
Pressure measuring method
Pressure receiving element
Gas to be measured
Scale indicating angleMedium and ambient
temperature Ambient humidity
Withstanding pressure of instrument body
Material of outer case
Withstanding impact
Withstanding vibration
Air volume and air velocityMeasuring differential pressureDiaphragmAir or non-corrosive gas (not liquid)Approximately 270 ° Wide-angle indication- 10 to + 50 ℃ (no freezing)90 % RH or less (no dewing)200 kPa (refer to p.104)Polycarbonate and polyamide100 m/s2(each 6 times on triaxial directions)5 to 10 Hz Amplitude : 10 mm10 to 50 Hz Acceleration : 39 m/s2
(each two hours on triaxial directions)
Applicable piping
Polarity of piping connector
Mass
・Vinyl, plastic or rubber tube (I.D. 6) ...The resinous piping connectors (installed) for vinyl or
plastic tube.
・Metal tube (O.D. 6 ± 0.1) ...Metal type piping connector (option) is needed.
・Hard plastic tube (O.D. 6 × I.D. 4) ...Metal type piping connector (option) and Inner sleeve set
(XIN6 × 4) are needed.(refer to p.92)
・The piping connector indicated red color is high pressure side and blue color is low pressure side.
・Enabling to convert the polarity by changing piping connectors of high pressure side for low pressure side.
Approximately 270 g
AccessoriesOne set of screws for installation Two sets of adaptors for installation (with main body) One set of nuts for installation (with main body)
WO81F WO81PC WO81PR
Specification
Pressure range codes Air volume and
air velocity range(example scale)
Standard installation positions
(refer to p.10)Accuracies (at 20 ℃ )
Material of pressure receiving element
Withstanding pressures of receiving element
(refer to p.104)
49 DMH
It is depend on specification of air velocity and air volume scale.
Upward horizontal (fixed)
± 5 % FS or less
Silicone rubber
10 kPa
49 DMV Vertical (fixed) 70 DMH Upward horizontal (fixed) 70 DMV Vertical (fixed) 100 DMH Upward horizontal (fixed)
± 2.5 % FS or less
100 DMV Vertical (fixed) 130 DMH Upward horizontal (fixed) 130 DMV Vertical (fixed) 180 DMH Upward horizontal (fixed)
40 kPa
180 DMV Vertical (fixed) 250 DM
Installation position from upward horizontal to vertical
is available.
300 DM 400 DM 580 DM 1000 DM
± 1.5 % FS or less 1.8 EM 3.2 EM 4.5 EM 8.5 EM 10 EM 150 kPa
(Note) Number :Rounding off, Magnification :×10, ×1000, ×10000, Unit :m3/h, m3/min, m3/h(nor), m3/min(nor), m/s◆In ordering out of above mentioned installation position, please order us or our agency beforehand. It must be adjusted before the factory shipment.
Air volume scale
Air velocity scale
8
WO81
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combinationof Manosys
Accessories
ApplicationCautions for useMaintenance
Outline drawing
WO81F Arrangement of the piping connectors
Manostar Gage WO81F
The piping connector installed on side view (in factory-setting)
φ 114 ± 0.3
69
79
27
φ 7
138
Flag pointer
Flag pointer
3 × φ 5 (installation holes)3 × 120 °segmentation
Pointer
φ 114
Hex.14
φ 128
Setting device of zero point
φ 101
Setting device ofthe green flag pointer
Setting device ofthe red flag pointer
Seal plug
Panel cut size
or 3 × M4 holes tapped
3 × φ 5 holes
3 × 120 °segmentation
Side arrangement of piping connectors
134121
φ 7
Hex.14
φ 6
± 0
.1
Hex.14
Hex.12
Appli
cable
pipin
g diam
eter
(143)
VT connector for vinyl or plastic tube
Caution
Tighten the piping connectors with the torque of 1 N・m.Tighten the seal plugs with the torque of 0.5 N・m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.
!( )
MT connector for metal tube VR rotary connector for vinyl or plastic tube
9
Low Differential Pressure Gage
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combination of Manosys
Accessories
ApplicationCautions for useMaintenance
WO81 Installation position
◆In ordering out of above mentioned installation position, please order us or our agency beforehand. It must be adjusted before the factory shipment.◆In case of ordering standerd installation position, you do not specify installation position. Please specify pressure range code in the specification table.
Vertical plane
a
a
b
Vertical plane
Verti
cal
Verti
cal
Downward horizontal Downward horizontalUpward horizontal Upward horizontal
Horizontal plane Horizontal planeInstall
ation p
osition
angle
upward
45 °
Installation position
angle downward 135 °
Installation position
angle downward 135 °
10 ° 10 °10 °
20 °20 °
20 °
a Specified installation position b Following installation position is available Standard installation position
Pressure range specified vertical or upward horizontal that is standard installation position. Installation position from upward horizonral to vertical is available.
Rear arrangement of the piping connector
φ 114 ± 0.3
Panel cut size
79
Appli
cable
pipi
ngdia
mete
r
Piping adaptor on back view(30)
Hex.14
Hex.12
φ 6
± 0
.1
or 3 × M4 holes tapped3 × 120 °segmentation
2 × φ 18 holes
3 × φ 5 holes
15
19
26
Hex.14Panel cut size
3 × φ 5 holesor 3 × M4 holes tapped3 × 120 °segmentation
Piping adaptor on back view(Long hole)
R9
φ 114 ± 0.379
To change arrangement of piping connectors of WO81F
WO81F have two piping connector ports on side and back view.It is possible to four kinds of arrangement by combination of piping.
Possible arrangement of piping connectors
Pipingconnector
PipingconnectorSeal plug
Seal plug
Impossible arrangement of piping connectors
Pipingconnector
Pipingconnector
Seal plug
Seal plug
VT connector for vinyl or plastic tube MT connector for metal tube
VR rotary connector for vinyl or plastic tube
0 ~ 50 Pa, 0 ~ 100 Pa, - 50 ~ + 50 Pa
The gage that pressure range is from 0 ~ 50 Pa is impossible to install on downward horizontal.
All other ranges except for the following
1.Use set of piping connectors, which is set of a red connector on high pressure side and a blue connector on low pressure side.
2.Be careful that there is impossible arrangement as shown on the right figure.
3.With seal plugs, be sure to close the two piping connector ports where connectors are not attached.
Caution
!
Caution
Tighten the piping connectors with the torque of 1 N·m.Tighten the seal plugs with the torque of 0.5 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.
!( )
10
WO81
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combinationof Manosys
Accessories
ApplicationCautions for useMaintenance
Manostar Gage WO81PCOutline drawing
Arrangement of piping connector (example)
How to install WO81PC
φ 7
17
φ 9
5
77
72φ 100
Panel cut size
φ 96 ± 0.3(hole)
Hex.14
Two sets of the installationbracket
φ 6
± 0
.1
Hex.14
(74)
Hex.12
Appli
cable
pipin
g diam
eter
70
63
φ 7
Hex.14
Driver
Screw A Screw A
Installation screw B
Installationadaptor
InstallationadaptorPanel
VT connector MT connector
VR connector
1. Loose screw A, and remove two installation adaptors.
2. Install the instrument body from the front side of the panel. Set two installation adaptors and tighten the screws A so that they were put into the original position.
3. Tighten two installation screws B alternately and fasten the instrument body to the panel.
Caution
Tighten the piping connectors with the torque of 1 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.
!( )
Caution
Tighten the installation screws B with the torque from 0.5 to 0.6 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.
!
11
Low Differential Pressure Gage
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combination of Manosys
Accessories
ApplicationCautions for useMaintenance
Manostar Gage WO81PROutline drawing
Arrangement of piping connector (example)
How to install WO81PR
100
100
6821
φ 9
5
φ 7
77
Four sets ofM4 installation screw
Hex.14
Panel cut size
80
80
φ 96 ± 0.3(hole)
80 ±
0.3
80 ± 0.3 4 × φ 5(hole)
φ 6
± 0
.1
(70)
Hex.14Hex.12
Appli
cable
pipin
g diam
eter
Hex.14
5966
φ 7
Max. thickness installed panel 6 mm
M4 nut
Spring washer
Plain washer
Spacer nut
VT connector MT connector
VR connector
1. Remove M4 nuts, spring washers and plain washers on four corners, but don't remove spacer nuts.
(When you install the instrument body on the panel, keep on attaching spacer nuts to the instrument body.)
2. After installing the instrument body on the panel, set plain washers and spring washers. Then tighten four sets of M4 nuts from the back side of panel.
Caution
Tighten the piping connectors with the torque of 1 N·m.Do not apply excessive torque more than necessary, otherwise it will damage the instrument body.Be sure to use a locking spanner at connectors to tighten the cap nut of metal tube. Be careful not to let the tightening torque directly load to the main body of the instrument.
!( )
Caution
If you install the instrument on the panel with no spacer nuts, the instrument body will be broken.
!
12
WO81
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combinationof Manosys
Accessories
ApplicationCautions for useMaintenance
Manostar Gage WO81Main structure
RoHS compliantAccessory for WO81
11
12
13
1098 76 5
44
32
1
Installation bracket to set for WO81 PC type Portable box for WO81 model
The combination shown in the above photo is a set of the installation adaptor.This set is intended for reserve. These two sets are attached to the body as standard accessory.
Product code TKA81PC Product code PB⊖01(The gage is not included.)
No. Name
1 Diaphragm
2 Low pressure side piping connector (blue)
3 High pressure side piping connector (red)
4 Seal plug
5 Scale plate
6 Setting device of zero point
7 Setting device of the flag pointer
8 Pointer
9 Flag pointer
10 Clear cover
11 Housing
12 Cover packing
13 Cover ring
13
Low Differential Pressure Gage
WO81
WO70
FR51A
MS30
MS61A
MS65
EB3C
EMD8
EMD7
EMT6
EMP5
EMA3
EMRT1
HWS15
EMT1
EMTGP1
EMT1H
Combination of Manosys
Accessories
ApplicationCautions for useMaintenance
RoHS compliantAccessory for WO81
* Because of quality improvement or any reason, some specifications are possibility of changing without notice.
PT connectorThe joint installed tube is push-in type. Use the optional tube (NT4-6, refer to p.88) or the applicable tube (JIS B8381-1).
PR connectorThe joint installed tube is push-in and rotary elbow type.
MT connector(ring joint type)This connector can be connected to the metal tube made from copper, aluminum and so on (O.D. 6, the tolerance ± 0.1).In case of connecting with stainless tube, use MTW connector.When this connector is connected to hard plastic tube (O.D. 6, I.D. 4), remove the brass-made sleeve and use the resinous inner sleeve set (XIN6 × 4, refer to p.88) that is the optional accessory.
MR connectorThis connector is rotary elbow type and can be connected to the metal tube (made from copper and aluminum and so on.).Applicable piping material is the same as MT connector.When this connector is connected to hard plastic tube (O.D. 6, I.D. 4), remove brass-made sleeve and use the resinous inner sleeve set (XIN6 × 4, refer to p.88) that is the optional accessory.
Piping adaptor on back view When you install MT, VR and MR connector (except for MTW connector) on back side port of WO81F type, this adaptor is necessary to avoid interference with connectors and panel. It is also necessary as a spacer to use a locking spanner at this adaptor.
MTW connector(double ring joint type)This connector can be connected to stainless tube (O.D. 6, the tolerance ± 0.1).This connector is made of stainless steel. (SUS316)
VR connectorThese connectors are rotary elbow type and can be connected to vinyl, plastic and rubber tube of I.D.6.
VT connectorTo attach vinyl, plastic or rubber tube to the instrument body (spare parts)
MT connector
Product code KGA81MT-H Product code KGA81MT-L
VR connector
PR connector
Product code KGA81VR-H
Product code KGA81PR-H
Product code KGA81VR-L
Product code KGA81PR-L
MR connector
Product code KGA81MR-H Product code KGA81MR-L
Piping adaptor on back view
Product code KGA81FBA-H Product code KGA81FBA-L
MTW connector
Product code KGA81MTW-H-S Product code KGA81MTW-L-S
Product code KGA81VT-L-P
Product code KGA81PT-L
Seal plug
Product code KGA81PLG
VT connector
PT connector
Product code KGA81VT-H-P
Product code KGA81PT-H
(for F type on back view)
High pressure side
High pressure side
High pressure side
High pressure side
High pressure side
High pressure side
High pressure side
High pressure side
Low pressure side
Low pressure side
Low pressure side
Low pressure side
Low pressure side
Low pressure side
Low pressure side
Low pressure side (for F type on back view)
14
WO81
April 2011 YAMAMOTO ELECTRIC WORKS CO.,LTD.
R
Manostar General Catalog Low differential pressure gage/Manostar gage/Manostar switch/Manosys
T H E G E N E R A L C A T A L O G
R
We appreciate the importance of air.Manostar gage WO81
April 2011The first edition contrasted with the 9th Japanese product catalog
Manostar General Catalog
1-2-3, Nishishiriike-cho, Nagata-ku, Kobe, Hyogo 653-0031 JAPANTEL. +81(78)621-7000 FAX. +81(78)621-7788
1-2-3, Nishishiriike-cho, Nagata-ku, Kobe, Hyogo 653-0031 JAPANTEL. +81(78)631-6000 FAX. +81(78)631-6020
ManufactuerSole Agent
Product Warranty
Warranty PeriodThis product warranty is valid for one year from the date of delivery to a place specified by an ordering party who has transacted directly with Yamamoto Electric Works Co., Ltd.
CoverageIf a product breaks down due to a reason for which we are responsible during the warranty period and you return the product to us, we will either repair or replace the product free of charge.This warranty does not cover:(1) Usage of the product under any inappropriate conditions or environment contrary to what is described
in our product catalog, specifications or manual.Handling or usage of the product other than as described in our product catalog, specifications or manual.
(2) Breakdown due to a reason other than a fault within our product.(3) Any product that has been modified or repaired by a party other than us.(4) Any breakdown due to a reason that was not foreseeable based on scientific and technical standards
applied at the time of shipment.(5) Any breakdown due to a reason not attributable to us such as a natural calamity or other disaster.
These terms of warranty represent our entire liability with respect to the product, and we shall have no liability for any other loss arising in connection with a breakdown of the product.
*This product warranty is only valid within Japan.
This document is a translation from the original Japanese version, and the original Japanese version has priority over this translation.Be sure to refer to the original Japanese for the details of this warranty.
!Caution
The Japanese original document shall always take precedenceover the translated versions.You should be sure to refer to the Japanese original document.
top related