TABLE: Combination DefinitionsComboName ComboType CaseName ScaleFactor

Text Text Text UnitlessULC-A1 Linear Add DEAD 1.4ULC-A1 SDL including 1st & 2nd stage construction 1.4ULC-A1 Vert soil on Roof - WT@ GL 1.4ULC-A1 Max Lat Soil(Ko) on Lt Wall - WT@ GL 1.4ULC-A1 Max Lat Soil(Ko) on Rt Wall - WT@ GL 1.4ULC-A1 Vert water on Roof - WT@ GL 1.2ULC-A1 Uplift on Base Slab WT@ GL 1.2ULC-A1 Lateral water on Lt Wall - WT@ GL 1.2ULC-A1 Lateral water on Rt Wall - WT@ GL 1.2ULC-A1 Live Load on Int Slabs 1.6ULC-A1 Vert Surcharge on Roof 2.353ULC-A1 Lat Surcharge on Lt Wall 2.353ULC-A1 Lat Surcharge on Rt Wall 2.353ULC-A2 Linear Add DEAD 1.4ULC-A2 SDL including 1st & 2nd stage construction 1.4ULC-A2 Vert soil on Roof - WT@ GL 1.4ULC-A2 Max Lat Soil(Ko) on Lt Wall - WT@ GL 1.4ULC-A2 Max Lat Soil(Ko) on Rt Wall - WT@ GL 1.4ULC-A2 Vert water on Roof - WT@ GL 1.2ULC-A2 Uplift on Base Slab WT@ GL 1.2ULC-A2 Lateral water on Lt Wall - WT@ GL 1.2ULC-A2 Lateral water on Rt Wall - WT@ GL 1.2ULC-A2 Vert Surcharge on Roof 2.353ULC-A2 Lat Surcharge on Lt Wall 2.353ULC-A2 Lat Surcharge on Rt Wall 2.353ULC-A3 Linear Add DEAD 1.4ULC-A3 SDL including 1st & 2nd stage construction 1.4ULC-A3 Vert soil on Roof - WT@ 1.5m below GL 1.4ULC-A3 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1.4ULC-A3 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1.4ULC-A3 Vert water on Roof - WT@ 1.5m below GL 1.4ULC-A3 Uplift on Base Slab WT@ 1.5m below GL 1.4ULC-A3 Lateral water on Lt Wall - WT@ 1.5m below GL 1.4ULC-A3 Lateral water on Rt Wall - WT@ 1.5m below GL 1.4ULC-A3 Live Load on Int Slabs 1.6ULC-A3 Vert Surcharge on Roof 2.353ULC-A3 Lat Surcharge on Lt Wall 2.353ULC-A3 Lat Surcharge on Rt Wall 2.353ULC-A4 Linear Add DEAD 1.4ULC-A4 SDL including 1st & 2nd stage construction 1.4ULC-A4 Vert soil on Roof - WT@ 1.5m below GL 1.4ULC-A4 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1.4ULC-A4 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1.4ULC-A4 Vert water on Roof - WT@ 1.5m below GL 1.4ULC-A4 Uplift on Base Slab WT@ 1.5m below GL 1.4

ULC-A4 Lateral water on Lt Wall - WT@ 1.5m below GL 1.4ULC-A4 Lateral water on Rt Wall - WT@ 1.5m below GL 1.4ULC-A4 Vert Surcharge on Roof 2.353ULC-A4 Lat Surcharge on Lt Wall 2.353ULC-A4 Lat Surcharge on Rt Wall 2.353ULC-A5 Linear Add DEAD 1.4ULC-A5 SDL including 1st & 2nd stage construction 1.4ULC-A5 Vert soil on Roof - WT@ Base 1.4ULC-A5 Min Lat Soil(Ka) on Lt Wall - WT@ Base 1ULC-A5 Min Lat Soil(Ka) on Rt Wall - WT@ Base 1ULC-A5 Live Load on Int Slabs 1.6ULC-A5 Live Load on Base Slab 1.6ULC-A5 Vert Surcharge on Roof 2.353ULC-A6 Linear Add DEAD 1.4ULC-A6 SDL including 1st & 2nd stage construction 1.4ULC-A6 Vert soil on Roof - WT@ Base 1.4ULC-A6 Min Lat Soil(Ka) on Lt Wall - WT@ Base 1ULC-A6 Min Lat Soil(Ka) on Rt Wall - WT@ Base 1ULC-A6 Vert Surcharge on Roof 2.353ULC-A7 Linear Add DEAD 1ULC-A7 SDL including 1st & 2nd stage construction 1ULC-A7 Vert soil on Roof - WT@ 1.5m below GL 1ULC-A7 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1.4ULC-A7 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1.4ULC-A7 Vert water on Roof - WT@ 1.5m below GL 1ULC-A7 Uplift on Base Slab WT@ 1.5m below GL 1ULC-A7 Lateral water on Lt Wall - WT@ 1.5m below GL 1.2ULC-A7 Lateral water on Rt Wall - WT@ 1.5m below GL 1.2ULC-A7 Lat Surcharge on Lt Wall 2.353ULC-A7 Lat Surcharge on Rt Wall 2.353ULC-A8 Linear Add DEAD 1ULC-A8 SDL including 1st & 2nd stage construction 1ULC-A8 Vert soil on Roof - WT@ 1m above GL 1ULC-A8 Max Lat Soil(Ko) on Lt Wall - WT@ 1m above GL 1.4ULC-A8 Max Lat Soil(Ko) on Rt Wall - WT@ 1m above GL 1.4ULC-A8 Vert water on Roof - WT@ 1m above GL 1.05ULC-A8 Uplift on Base Slab WT@ 1m above GL 1.05ULC-A8 Lateral water on Lt Wall - WT@ 1m above GL 1.05ULC-A8 Lateral water on Rt Wall - WT@ 1m above GL 1.05ULC-A9 Linear Add DEAD 1.4ULC-A9 SDL including 1st & 2nd stage construction 1.4ULC-A9 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1.4ULC-A9 Vert soil on Roof (Left Higher) - WT@ 4.5m below GL 1.4ULC-A9 Min Lat Soil(Ka) on Rt Wall - WT@ 4.5m below GL 1.4ULC-A9 Lateral water on Lt Wall - WT@ 1.5m below GL 1.2ULC-A9 Vert water on Roof (Left Higher) - WT@ 4.5m below GL 1.2ULC-A9 Uplift on Base Slab (Left Higher) WT@ 4.5m below GL 1.2ULC-A9 Lateral water on Rt Wall - WT@ 4.5m below GL 1.2

ULC-A9 Live Load on Int Slabs 1.6ULC-A9 Live Load on Base Slab 1.6ULC-A9 Vert Surcharge on Roof 2.353ULC-A9 Lat Surcharge on Lt Wall 2.353ULC-A10 Linear Add DEAD 1.4ULC-A10 SDL including 1st & 2nd stage construction 1.4ULC-A10 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1.4ULC-A10 Vert soil on Roof (Left Higher) - WT@ 4.5m below GL 1.4ULC-A10 Min Lat Soil(Ka) on Rt Wall - WT@ 4.5m below GL 1.4ULC-A10 Lateral water on Lt Wall - WT@ 1.5m below GL 1.2ULC-A10 Vert water on Roof (Left Higher) - WT@ 4.5m below GL 1.2ULC-A10 Uplift on Base Slab (Left Higher) WT@ 4.5m below GL 1.2ULC-A10 Lateral water on Rt Wall - WT@ 4.5m below GL 1.2ULC-A10 Lat Surcharge on Lt Wall 2.353ULC-A11 Linear Add DEAD 1.4ULC-A11 SDL including 1st & 2nd stage construction 1.4ULC-A11 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1.4ULC-A11 Vert soil on Roof (Right Higher) - WT@ 4.5m below GL 1.4ULC-A11 Min Lat Soil(Ka) on Lt Wall - WT@ 4.5m below GL 1.4ULC-A11 Lateral water on Rt Wall - WT@ 1.5m below GL 1.2ULC-A11 Vert water on Roof(Right Higher) - WT@ 4.5m below GL 1.2ULC-A11 Uplift on Base Slab (Right Higher) WT@ 4.5m below GL 1.2ULC-A11 Lateral water on Lt Wall - WT@ 4.5m below GL 1.2ULC-A11 Live Load on Int Slabs 1.6ULC-A11 Live Load on Base Slab 1.6ULC-A11 Vert Surcharge on Roof 2.353ULC-A11 Lat Surcharge on Rt Wall 2.353ULC-A12 Linear Add DEAD 1.4ULC-A12 SDL including 1st & 2nd stage construction 1.4ULC-A12 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1.4ULC-A12 Vert soil on Roof (Right Higher) - WT@ 4.5m below GL 1.4ULC-A12 Min Lat Soil(Ka) on Lt Wall - WT@ 4.5m below GL 1.4ULC-A12 Lateral water on Rt Wall - WT@ 1.5m below GL 1.2ULC-A12 Vert water on Roof(Right Higher) - WT@ 4.5m below GL 1.2ULC-A12 Uplift on Base Slab (Right Higher) WT@ 4.5m below GL 1.2ULC-A12 Lateral water on Lt Wall - WT@ 4.5m below GL 1.2ULC-A12 Lat Surcharge on Rt Wall 2.353SLC-B1 Linear Add DEAD 1SLC-B1 SDL including 1st & 2nd stage construction 1SLC-B1 Vert soil on Roof - WT@ GL 1SLC-B1 Max Lat Soil(Ko) on Lt Wall - WT@ GL 1SLC-B1 Max Lat Soil(Ko) on Rt Wall - WT@ GL 1SLC-B1 Vert water on Roof - WT@ GL 1SLC-B1 Uplift on Base Slab WT@ GL 1SLC-B1 Lateral water on Lt Wall - WT@ GL 1SLC-B1 Lateral water on Rt Wall - WT@ GL 1SLC-B1 Live Load on Int Slabs 1SLC-B1 Vert Surcharge on Roof 1

SLC-B1 Lat Surcharge on Lt Wall 1SLC-B1 Lat Surcharge on Rt Wall 1SLC-B2 Linear Add DEAD 1SLC-B2 SDL including 1st & 2nd stage construction 1SLC-B2 Vert soil on Roof - WT@ GL 1SLC-B2 Max Lat Soil(Ko) on Lt Wall - WT@ GL 1SLC-B2 Max Lat Soil(Ko) on Rt Wall - WT@ GL 1SLC-B2 Vert water on Roof - WT@ GL 1SLC-B2 Uplift on Base Slab WT@ GL 1SLC-B2 Lateral water on Lt Wall - WT@ GL 1SLC-B2 Lateral water on Rt Wall - WT@ GL 1SLC-B2 Vert Surcharge on Roof 1SLC-B2 Lat Surcharge on Lt Wall 1SLC-B2 Lat Surcharge on Rt Wall 1SLC-B3 Linear Add DEAD 1SLC-B3 SDL including 1st & 2nd stage construction 1SLC-B3 Vert soil on Roof - WT@ 1.5m below GL 1SLC-B3 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1SLC-B3 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1SLC-B3 Vert water on Roof - WT@ 1.5m below GL 1SLC-B3 Uplift on Base Slab WT@ 1.5m below GL 1SLC-B3 Lateral water on Lt Wall - WT@ 1.5m below GL 1SLC-B3 Lateral water on Rt Wall - WT@ 1.5m below GL 1SLC-B3 Live Load on Int Slabs 1SLC-B3 Vert Surcharge on Roof 1SLC-B3 Lat Surcharge on Lt Wall 1SLC-B3 Lat Surcharge on Rt Wall 1SLC-B4 Linear Add DEAD 1SLC-B4 SDL including 1st & 2nd stage construction 1SLC-B4 Vert soil on Roof - WT@ 1.5m below GL 1SLC-B4 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1SLC-B4 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1SLC-B4 Vert water on Roof - WT@ 1.5m below GL 1SLC-B4 Uplift on Base Slab WT@ 1.5m below GL 1SLC-B4 Lateral water on Lt Wall - WT@ 1.5m below GL 1SLC-B4 Lateral water on Rt Wall - WT@ 1.5m below GL 1SLC-B4 Vert Surcharge on Roof 1SLC-B4 Lat Surcharge on Lt Wall 1SLC-B4 Lat Surcharge on Rt Wall 1SLC-B5 Linear Add DEAD 1SLC-B5 SDL including 1st & 2nd stage construction 1SLC-B5 Vert soil on Roof - WT@ 5m below GL 1SLC-B5 Min Lat Soil(Ka) on Lt Wall - WT@ 5m below GL 1SLC-B5 Min Lat Soil(Ka) on Rt Wall - WT@ 5m below GL 1SLC-B5 Vert water on Roof - WT@ 5m below GL 1SLC-B5 Uplift on Base Slab WT@ 5m below GL 1SLC-B5 Lateral water on Lt Wall - WT@ 5m below GL 1SLC-B5 Lateral water on Rt Wall - WT@ 5m below GL 1

SLC-B5 Live Load on Int Slabs 1SLC-B5 Live Load on Base Slab 1SLC-B5 Vert Surcharge on Roof 1SLC-B6 Linear Add DEAD 1SLC-B6 SDL including 1st & 2nd stage construction 1SLC-B6 Vert soil on Roof - WT@ 5m below GL 1SLC-B6 Min Lat Soil(Ka) on Lt Wall - WT@ 5m below GL 1SLC-B6 Min Lat Soil(Ka) on Rt Wall - WT@ 5m below GL 1SLC-B6 Vert water on Roof - WT@ 5m below GL 1SLC-B6 Uplift on Base Slab WT@ 5m below GL 1SLC-B6 Lateral water on Lt Wall - WT@ 5m below GL 1SLC-B6 Lateral water on Rt Wall - WT@ 5m below GL 1SLC-B6 Vert Surcharge on Roof 1SLC-B7 Linear Add DEAD 1SLC-B7 SDL including 1st & 2nd stage construction 1SLC-B7 Vert soil on Roof - WT@ 1.5m below GL 1SLC-B7 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1SLC-B7 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1SLC-B7 Vert water on Roof - WT@ 1.5m below GL 1SLC-B7 Uplift on Base Slab WT@ 1.5m below GL 1SLC-B7 Lateral water on Lt Wall - WT@ 1.5m below GL 1SLC-B7 Lateral water on Rt Wall - WT@ 1.5m below GL 1SLC-B7 Lat Surcharge on Lt Wall 1SLC-B7 Lat Surcharge on Rt Wall 1SLC-B8 Linear Add DEAD 1SLC-B8 SDL including 1st & 2nd stage construction 1SLC-B8 Vert soil on Roof - WT@ GL 1SLC-B8 Max Lat Soil(Ko) on Lt Wall - WT@ GL 1SLC-B8 Max Lat Soil(Ko) on Rt Wall - WT@ GL 1SLC-B8 Vert water on Roof - WT@ GL 1SLC-B8 Uplift on Base Slab WT@ GL 1SLC-B8 Lateral water on Lt Wall - WT@ GL 1SLC-B8 Lateral water on Rt Wall - WT@ GL 1SLC-B9 Linear Add DEAD 1SLC-B9 SDL including 1st & 2nd stage construction 1SLC-B9 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1SLC-B9 Vert soil on Roof (Left Higher) - WT@ 4.5m below GL 1SLC-B9 Min Lat Soil(Ka) on Rt Wall - WT@ 4.5m below GL 1SLC-B9 Lateral water on Lt Wall - WT@ 1.5m below GL 1SLC-B9 Vert water on Roof (Left Higher) - WT@ 4.5m below GL 1SLC-B9 Uplift on Base Slab (Left Higher) WT@ 4.5m below GL 1SLC-B9 Lateral water on Rt Wall - WT@ 4.5m below GL 1SLC-B9 Live Load on Int Slabs 1SLC-B9 Live Load on Base Slab 1SLC-B9 Vert Surcharge on Roof 1SLC-B9 Lat Surcharge on Lt Wall 1SLC-B10 Linear Add DEAD 1SLC-B10 SDL including 1st & 2nd stage construction 1

SLC-B10 Max Lat Soil(Ko) on Lt Wall - WT@ 1.5m below GL 1SLC-B10 Vert soil on Roof (Left Higher) - WT@ 4.5m below GL 1SLC-B10 Min Lat Soil(Ka) on Rt Wall - WT@ 4.5m below GL 1SLC-B10 Lateral water on Lt Wall - WT@ 1.5m below GL 1SLC-B10 Vert water on Roof (Left Higher) - WT@ 4.5m below GL 1SLC-B10 Uplift on Base Slab (Left Higher) WT@ 4.5m below GL 1SLC-B10 Lateral water on Rt Wall - WT@ 4.5m below GL 1SLC-B10 Lat Surcharge on Lt Wall 1SLC-B11 Linear Add DEAD 1SLC-B11 SDL including 1st & 2nd stage construction 1SLC-B11 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1SLC-B11 Vert soil on Roof (Right Higher) - WT@ 4.5m below GL 1SLC-B11 Min Lat Soil(Ka) on Lt Wall - WT@ 4.5m below GL 1SLC-B11 Lateral water on Rt Wall - WT@ 1.5m below GL 1SLC-B11 Vert water on Roof(Right Higher) - WT@ 4.5m below GL 1SLC-B11 Uplift on Base Slab (Right Higher) WT@ 4.5m below GL 1SLC-B11 Lateral water on Lt Wall - WT@ 4.5m below GL 1SLC-B11 Live Load on Int Slabs 1SLC-B11 Live Load on Base Slab 1SLC-B11 Vert Surcharge on Roof 1SLC-B11 Lat Surcharge on Rt Wall 1SLC-B12 Linear Add DEAD 1SLC-B12 SDL including 1st & 2nd stage construction 1SLC-B12 Max Lat Soil(Ko) on Rt Wall - WT@ 1.5m below GL 1SLC-B12 Vert soil on Roof (Right Higher) - WT@ 4.5m below GL 1SLC-B12 Min Lat Soil(Ka) on Lt Wall - WT@ 4.5m below GL 1SLC-B12 Lateral water on Rt Wall - WT@ 1.5m below GL 1SLC-B12 Vert water on Roof(Right Higher) - WT@ 4.5m below GL 1SLC-B12 Uplift on Base Slab (Right Higher) WT@ 4.5m below GL 1SLC-B12 Lateral water on Lt Wall - WT@ 4.5m below GL 1SLC-B12 Lat Surcharge on Rt Wall 1SLS-Envelope Envelope SLC-B1 1SLS-Envelope SLC-B2 1SLS-Envelope SLC-B3 1SLS-Envelope SLC-B4 1SLS-Envelope SLC-B5 1SLS-Envelope SLC-B6 1SLS-Envelope SLC-B7 1SLS-Envelope SLC-B8 1SLS-Envelope SLC-B9 1SLS-Envelope SLC-B10 1SLS-Envelope SLC-B11 1SLS-Envelope SLC-B12 1ULS-Envelope Envelope ULC-A1 1ULS-Envelope ULC-A2 1ULS-Envelope ULC-A3 1ULS-Envelope ULC-A4 1ULS-Envelope ULC-A5 1

ULS-Envelope ULC-A6 1ULS-Envelope ULC-A7 1ULS-Envelope ULC-A8 1ULS-Envelope ULC-A9 1ULS-Envelope ULC-A10 1ULS-Envelope ULC-A11 1ULS-Envelope ULC-A12 1

TABLE: Program ControlProgramName Version ProgLevel LicenseNum LicenseOS LicenseSC LicenseBR LicenseHT

Text Text Text Text Text Text Text TextSAP2000 15.2.1 Ultimate Yes Yes No No

CurrUnits SteelCode ConcCode AlumCode ColdCode BridgeCodeText Text Text Text Text Text

KN, m, C AISC360-05/IBC2006 ACI 318-05/IBC2003 AA-ASD 2000 AISI-ASD96 AASHTO LRFD 2007

RegenHinge BSchedGUIDText Text