led par bulbs
Post on 03-Jan-2017
224 Views
Preview:
TRANSCRIPT
Designed for reliability and optimal performance, the HyLite LED PAR Bulbs are highly efficient bulbs that can replace standard Halogen, Incandescent and CFL bulb for significant energy savings.
HyLite LED PAR Bulbs last up to 17 years (at an on-time of 8 hrs./day) or up to 23 years (at an on-time of 6 hrs./day) for extended use. It uses up to 88% less energy compared to a standard incandescent, up to 85% less energy halogen light bulb, and up to 50% less energy compared to a CFL bulb, significantly reducing your carbon footprint while maintaining the highest quality of light.
• ReducesEnergyConsumptionandOperatingCostsbyupto90%.
• UltraLongLife:50,000hours.Eliminatesthehassleofrepeatedrelamping in busy areas.
• Maintenance-freeOperation:Lastsupto50timeslongerthanincandescentbulb and up to 20 times longer than Halogen bulb.
• SolidState:High-ShockandVibration-Resistant.
• Easilyinstalledintostandardfixtures.
•InstantStartandRestart:Nowarmuptimerequired.
• Brilliantlybrightwhilerunningcool(upto90%lessheatthanIncandescent).
•NoUV(ultraviolet)andIR(infrared)levels.
• LightPollutionReduction:Directionallightoutput.
• Soft,No-GlareLight:Givesvisualcomfort.
• SafeandReliable:IsolatedCircuitDesign.
• GoodHeatDissipationwithproprietary-designedAluminumAlloyHousing.
• ExcellentThermalManagement:Avoidsheatdamage.
• UnlikeCFLitcontainsNoMercuryorLead.
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead,Mercury, PhosphororToxicGases.Nodisposalrequirements.FacilitatesLEED® points.
•EnvironmentallyFriendly:98%oftheHyLiteLEDBulbisrecyclable.
• CECertified.IP43.
Page:1of5
Idealforhigh-qualityilluminationin:
• RetailandShoppingMalls • RestaurantLighting
• HospitalityLighting • OfficeLighting
• ArtGalleries&Museums • ShowroomLighting
• OtherCommercialandInstitutionalLightingApplications
HyLite LEDLightBulbs-Upto50,000hourRatedPerformanceLifeEnjoy SuperiorQualityofLightandgetEnergySavingsof85% over Halogen Bulbs and of 88% over Incandescent Bulbs today!
Equivalentto/EnergySavings(%)*
HyLite Halogen Incandescent CFL LED Bulb Bulb Bulb Bulb
PAR20,8W 50W(84%) 60W(87%) 16W(50%) PAR30,12W 75W(84%) 90W(87%) 24W(50%) PAR 38, 18W 120W (85%) 150W (88%) 36W (50%)
*DoesnotincludeBallastLoss,Maintenance,ReplacementLampSavings andDisposalCostswhichamounttoadditionalSavingsof30~50%!
LED PAR Bulbs
PAR 30
12W
PAR 20
8W
PAR 38
18W
Voltage:AC100-277V,50/60Hz PowerFactor:≥0.9 Max.THD(%):<20 AmbientWorkingTemp.:-4°F~+104°F(-20°C~+40°C)
HumidityRange:10~90% Productswith(CCT)2500°K-6500°Kareavailableuponrequest.
LED PAR Bulbs
Ø 2.45”(62mm)
2.2”
(56m
m)
3.5”
(90m
m)
E26/E27Ø 3.6” (92mm)
2” (5
0mm
)
4” (1
03m
m)
E26/E27
E26/E27
Ø 4.75” (120mm)
3” (8
0mm
)
5.25
” (13
2mm
)
PAR 38, 18WPAR 20, 8W
PAR 30, 12W
Model Dimmable ColorTemp. Lumens Efficacy Beam Base Dimensions&Weight(each) Case Case No. Watts Available (CCT) (lm) (lm/w) Angle CRI Type Height Width Weight Qty. Weight
HL-P20-8W-E26-27K 8 100V-130V 2700°K 420 53 45° >80 E26/E27 3.5In. 2.5In. 4oz. 50 20lbs. Only (WarmWhite) Medium (90mm) (62mm) (120g) (9Kg.)
HL-P20-8W-E26-50K 8 100V-130V 5000°K 560 71 45° >80 E26/E27 3.5In. 2.5In. 4oz. 50 20lbs. Only (Daylight) Medium (90mm) (62mm) (120g) (9Kg.)
HL-P30-12W-E26-27K 12 100V-130V 2700°K 790 62 45° >80 E26/E27 4In. 3.5In. 8oz. 20 13lbs. Only (WarmWhite) Medium (103mm) (92mm) (220g) (6Kg.)
HL-P30-12W-E26-50K 12 100V-130V 5000°K 1045 82 45° >80 E26/E27 4In. 3.5In. 8oz. 20 13lbs. Only (Daylight) Medium (103mm) (92mm) (220g) (6Kg.)
HL-P38-18W-E26-27K 18 100V-130V 2700°K 1080 60 45° >80 E26/E27 5.25In. 4.75In. 20oz. 20 27lbs. Only (WarmWhite) Medium (132mm) (120mm) (550g) (12Kg.)
HL-P38-18W-E26-50K 18 100V-130V 5000°K 1440 81 45° >80 E26/E27 5.25In. 4.75In. 20oz. 20 27lbs. Only (Daylight) Medium (132mm) (120mm) (550g) (12Kg.)
Warning - Risk of Fire or Electric Shock
• Disable all power to the bulb before inspection, installation, or removal. Failure to do so will createahazardousandfatalworkingenvironment.
• SuitableforUseinDampLocations.Fixturesmustbeinstalledinaccordance withNational,State,and/orLocalElectricalCodes.DoNotOpen–NoUser ServiceablePartsInside.
• Operateinfixturesthatprovidethefreeflowofairaroundthelampheatsink.
• Notintendedforusewithemergencyexitfixturesoremergencyexitlights.
Page:2of5
PAR20:8W
Average Beam Angle (10%): 114.8°
HL-P20-8W-E26-27K
C0/180, 117.7°C30/210, 112.2°C60/240, 113.2°
UNIT: cd
C90/270, 116.0°
Average IlluminanceC0/180
C90/270
Photometrics
Distance (m)
-25 -20 -15 -10 -5 0 5 10 15 20 250
0.350.7
1.051.41.752.12.45
2.83.153.5E (lx) MH = 10m
1 m3.3 ft.
Height
2 m6.5 ft.
3 m10 ft.
4 m13 ft.
5 m16 ft.
209.4/334.8 lx
52.35/83.70 lx
23.27/37.20 lx
13.09/20.92 lx
8.4/13.39 lx
0.99 m
1.98 m
2.97 m
3.96 m
4.95 m
Angle: 52.69° DiameterEavg, Emax
3.25 ft.
6.5 ft.
9.75 ft.
13 ft.
16.25 ft.
Flux Out: 170.8 lm
19.46/31.10 fc
4.86/7.78 fc
2.16/3.46 fc
1.22/1.94 fc
0.78/1.2 fc
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
70
140
210
280
350
Average Beam Angle (10%): 117.3°
HL-P20-8W-E26-50K
C0/180, 115.7°C30/210, 118.8°C60/240, 115.6°
UNIT: cd
C90/270, 119.2°
Average IlluminanceC0/180
C90/270
Photometrics
Distance (m)
-25 -20 -15 -10 -5 0 5 10 15 20 250
0.51.0
1.52.02.53.03.5
4.04.55.0E (lx) MH = 10m
1 m3.3 ft.
Height
2 m6.5 ft.
3 m10 ft.
4 m13 ft.
5 m16 ft.
273.2/456 lx
68.30/114 lx
30.36/50.67 lx
17.08/28.5 lx
10.93/18.24 lx
1.06 m
2.12 m
3.18 m
4.24 m
5.30 m
Angle: 55.85° DiameterEavg, Emax
3.5 ft.
7.0 ft.
10.5 ft.
14.0 ft.
17.5 ft.
Flux Out: 242.7 lm
25.38/42.36 fc
6.35/10.59 fc
2.82/4.71 fc
1.59/2.65 fc
1.02/1.70 fc
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
100
200
300
400
500
Page:3of5
PAR30:12W
Average Beam Angle (10%): 85.8°
HL-P30-12W-E26-27K
Average IlluminanceC0/180
C90/270
Photometrics
Distance (m)
-25 -20 -15 -10 -5 0 5 10 15 20 250
1.53.0
4.56.07.59.010.5
12.013.515.0E (lx) MH = 10m
1 m3.3 ft.
Height
2 m6.5 ft.
3 m10 ft.
4 m13 ft.
5 m16 ft.
657.5/1027 lx
164.4/256.7 lx
73.06/114.1 lx
41.10/64.17 lx
26.30/41.07 lx
0.88 m
1.65 m
2.48 m
3.30 m
4.13 m
Angle: 44.83° DiameterEavg, Emax
2.7 ft.
5.4 ft.
8.1 ft.
10.8 ft.
13.5 ft.
Flux Out: 372.2 lm
61.09/95.38 fc
15.27/23.84 fc
6.79/10.60 fc
3.82/5.96 fc
2.44/3.82 fc
C0/180, 85.6°C30/210, 85.7°C60/240, 86.6°
UNIT: cd
C90/270, 85.4°0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
300
600
900
1200
1500
Average Beam Angle (10%): 85.5°
HL-P30-12W-E26-50K
Average IlluminanceC0/180
C90/270
Photometrics
Distance (m)
-25 -20 -15 -10 -5 0 5 10 15 20 250
1.53.0
4.56.07.59.010.5
12.013.515.0E (lx) MH = 10m
1 m3.3 ft.
Height
2 m6.5 ft.
3 m10 ft.
4 m13 ft.
5 m16 ft.
893.1/1400 lx
223.3/350 lx
99.23/155.6 lx
55.82/87.50 lx
35.72/56.00 lx
0.82 m
1.64 m
2.45 m
3.27 m
4.09 m
Angle: 44.47° DiameterEavg, Emax
2.7 ft.
5.4 ft.
8.0 ft.
10.75 ft.
13.4 ft.
Flux Out: 505.5 lm
82.97/130.1 fc
20.74/32.52 fc
9.22/14.45 fc
5.19/8.13 fc
3.32/5.20 fc
C0/180, 85.4°C30/210, 86.3°C60/240, 85.3°
UNIT: cd
C90/270, 85.1°0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
300
600
900
1200
1500
Page:4of5
PAR38:18W
Average Beam Angle (10%): 76.7°
HL-P38-18W-E26-27K
Average IlluminanceC0/180
C90/270
Photometrics
Distance (m)
-25 -20 -15 -10 -5 0 5 10 15 20 250
24
68101214
161820E (lx) MH = 10m
1 m3.3 ft.
Height
2 m6.5 ft.
3 m10 ft.
4 m13 ft.
5 m16 ft.
1123/1746 lx
280.7/436.6 lx
124.8/194.0 lx
70.18/109.1 lx
44.92/69.85 lx
0.73 m
1.46 m
2.19 m
2.93 m
3.66 m
Angle: 40.18° DiameterEavg, Emax
2.4 ft.
4.8 ft.
7.2 ft.
9.6 ft.
12 ft.
Flux Out: 519.8 lm
104.3/162.2 fc
26.08/40.56 fc
11.59/18.03 fc
6.52/10.14 fc
4.17/6.49 fc
C0/180, 78.7°C30/210, 78.0°C60/240, 75.2°
UNIT: cd
C90/270, 75.1°0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
400
800
1200
1600
2000
Average Beam Angle (10%): 75.1°
HL-P38-18W-E26-50K
Average IlluminanceC0/180
C90/270
Photometrics
Distance (m)
-25 -20 -15 -10 -5 0 5 10 15 20 250
2.55
7.51012.51517.5
2022.525E (lx) MH = 10m
1 m3.3 ft.
Height
2 m6.5 ft.
3 m10 ft.
4 m13 ft.
5 m16 ft.
1617/2514 lx
404.3/628.4 lx
179.7/279.3 lx
101.1/157.1 lx
64.69/100.5 lx
0.7 m
1.45 m
2.15 m
2.85 m
3.6 m
Angle: 39.25° DiameterEavg, Emax
2.3 ft.
4.7 ft.
7.0 ft.
9.4 ft.
12 ft.
Flux Out: 673.1 lm
150.2/233.5 fc
37.56/58.38 fc
16.69/25.95 fc
9.39/14.60 fc
6.01/9.34 fc
C0/180, 75.2°C30/210, 74.9°C60/240, 74.5°
UNIT: cd
C90/270, 75.7°0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
500
1000
1500
2000
2500
Page:5of5©2013ARVA,LLC.,USA HyLiteLEDLighting.com