JEOL 7000F. Exploring the JEOL Control Program. Goals. Look at all of the menu items and their functions. Note where icon brings up the same function. Look at any items not in menu but brought up by icons and vice versa. Other items of interest?. Basic Screen. Title Bar. File Menu - 1. - PowerPoint PPT Presentation

TRANSCRIPT

JEOL 7000F

Exploring the

JEOL Control Program

Goals

• Look at all of the menu items and their functions.– Note where icon brings up the same function.

• Look at any items not in menu but brought up by icons and vice versa.

• Other items of interest?

Basic Screen

Title Bar

File Menu - 1

• User Login• Image File Handling

– We will look at elsewhere

• Image Save As …• Quick Save Options• Auto Batch Export• Print - NO PRINTER• Exit

File Menu - User Login

• Advantage is storage of your individual image observation conditions.

• List of users.• Login as user brings

up password.

File Menu – Quick Save Options

File Menu - Image Save As …

• Brings up the fairly typical “Save As” Dialog Box.

File Menu - Auto Batch Export

• Allows transfer of image files in a batch.

• Non-exported files do not contain associated text and scale bar on the image.

Edit Menu

• Copies the image to the clipboard.

• Example, the can be pasted to MS Paint

Control Menu

• Column• Contrast/Brightness

– Need live image– Use knobs on JEOL

Operation Pad

• Add Images• Alignment

– See JEOL Operation Pad

– We will discuss later

Control Menu – Column 1

• Column Control can be reached either through the Control Menu pull down or,

• Clicking the Column Icon on the Tool Bar.

Control Menu – Column 2

• Accelerating Voltage• High-light and type in new value

• Click arrows– From 0.5 – 2.9 kV steps are 0.01 kV– From 3.0 – 30 kV steps are 0.10 kV

• OL Aperture– Set to the same value as the OL Aperture on column– For most users, almost always “4”

Control Menu – Column 3

• SEI Detector• Usually On (green)

• Mode• Sets the bias on the Faraday cage in front of the SE

scintillator.• Normally at “3” but set to a lower value if using high beam

currents (Large spot sizes).

Control Menu – Column 4

• Column Mode:• SEM - Leave it here (green)• ECP – Electron channeling - No body does this now.• ALP – Alignment usage for service engineer.

• Focus:• Can course focus using the numbers and slide

• Probe (beam) current:• Higher the number the more current in the electron beam hitting the

sample.

Control Menu – Column 5

• Scan Rotation:– Normally this is OFF (0)

• DFC– Almost always OFF

Control Menu – Add Images

• Allows mixing of different signals.

• For example, backscattered and secondary electron.

• Not often used.

Image Menu – General – 1

• Image File Handler …• Display Thumbnails

– Self explanatory

• Use 24 Bits for Export– Self explanatory

• Save to AnalySIS– AnalySIS is an imaging

database program.

• Select SIS Database

Image Menu – General – 2

• Show Pan Window with 2K Image– Opens pan window

with large 2k x 2k images

• Overlap …– Overlaps 2 images

• Contrast/Brightness/Gamma …

• Image Processing– Various image filters

Image Menu – Image File Handler

• Several ways to get there:– Icon on Tool bar– Image menu– File Menu

Image File Handler – 1

• Select a folder for saving images,

• Print - No printer• Export

– Adds scale bar and other information to stored image

– Much easier to use theAuto Batch Exportin the File Menu drop down if you have many images you want to export.

• Other options are generally self explanatory

Image File Handler – 2

• Saw this window before in looking at the File Menu.

• You see the same thing if you go to File Menu, then Image Save As

Image Menu – Contrast/Brightness/Gamma

• Tool bar icon• Histogram

– Gray scale– Gain adjustment slider

• Correction curve• Hi – Lo Thresholds• Linearize – Equalize –

Invert• Contrast/Brightness/

Gamma Sliders

Tools Menu

• Annotate and Measurement– Add and edit text– Measure distance

between two arbitrary points

• Cursor Measurement– Measures distance

between two points specified by the cursor.

Tools Menu – Annotate and Measurement

• Append Annotate and Measure– USE ICON

• Load Annotate and Measure– Loads saved text

• Save Annotate …– Saves the text created

• Delete All Annotate …– Deletes all text and figures

on the screen

• Set Measurement …

Append Annotate and Measurement

Append Annotate and MeasurementExample

Set Measurement Magnify Parameters

Measurement Using the Cursors

Stage Menu • Exchange• Control• Map Control• Motion Abort

– ESC Key stops movement of the stage.

• Alarm Recovery– If specimen holder

comes in contact with a detector then Alarm Sounds; holder stops.Alarm Recovery frees stage to move

Stage Menu – Exchange

• Described previously• Specimen Exchange

operations

Stage Menu – Control• Step Movement of the

stage• Relative position

indicator• Stage movement

operation• STOP & Center

buttons– Stop – stops stage

movement– Center – moves to

specimen exchange

Stage Menu – Control (Detail)

Stage Menu – Map Control

• Snap Shot– Designate an

observation range on a saved image, then move the stage to the range

• Stage Map– Movement of stage

through Points File orStage Map

Snap Shot (Detail)

Stage Map (Detail)

Setup Menu

• Recipe Setup• Operation• Stage

• User Login– Sets user login

conditions

Setup Menu – Recipe

Setup Menu – Operation

Setup Menu – Stage

Maintenance Menu

• Normally these should not be altered.

• Gun• Stage• JEOLS …

– for JEOL engineer only

Tool Bar

Other Items

• REPLACE ALL TOOLS

• Dispose of trash

• Leave the lab in good order.

• LOG IN / LOG OUT

• Note any problems