BA LU S T R A D E S YS T E M S
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
ISSUE 11/17
®JURALCO EDGEBALUSTRADE SYSTEMS
BA LU S T R A D E S YS T E M S
Page 2
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems
Juralco Aluminium Building Products Ltd designs and distributes specialist aluminium
joinery systems through a national network of franchised fabricators and agents.
0
For more than 25 years we have been at the forefront of specialist aluminium door and
window products suitable for New Zealand joinery and building methods. Our
comprehensive product range includes security and insect screens, balustrades and gates,
shutters and awnings, shower screens, wardrobe doors and organisers and internal doors.
0
®The Juralco EDGE Balustrading Systems is an architectural balustrade system designed to
provide a wide range of design options in both contemporary glass and in more
conventional aluminium metal balusters.
®The Juralco EDGE Balustrade system is an architectural balustrade system designed to provide a range of modern design options in both glass and
aluminium. Mounting to a deck can be done a variety of ways to timber, concrete, steel, and to waterproof membranes.
Toughened Glass infills can be 6mm, 8mm or 10mm, either fully framed (6mm) or semi frameless (8, 10mm) with handrails either top or side mounted.
Toughened 13.2mm Laminated glass can be used for semi frameless applications.
For a more traditional look Vertical metal infills are available in 17mm sq and 60mm x 17mm slats, all in powder coated colour of your choice.
All designs are available with a variety of handrails. Tables are shown for various baluster spacings, heights and wind zones.
All mountings and installation recommendations conform to the latest AS/NZS1170 and NZS 4223.3.2016 regulations.
Our installers are all very experienced and can recommend a balustrading system to fit your design requirements and budget.
All pages © Copyright Juralco Aluminium Building Products Ltd, 2017
®Top left illustration - Top Mount EDGE Balustrade with Metal Balusters®Bottom left illustration - Top Mount EDGE Balustrade with Metal Balusters
Illustration above - Face Fixed EDGE Balustrade with Laminated glass,
to Concrete®Cover illustration - Face Fixed EDGE Semi Frameless Balustrades
BA LU S T R A D E S YS T E M S
Page 3
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Heading Pages Description
Specifications 4 Juralco standard specification sheet and Powder coating recommendations
Configurations 5 - 8 Shows typical Glass and Batten style Balustrade layouts Includes specifications for Interlinking Rail to NZS4223.3.2016 for Semiframeless Glass balustrades
Materials 9 - 16 All Extrusions and Components
Post Mount Types 17 Shows the Four Post mount types
Deck Nailings 18 - 19 Shows details of Double Boundary Joist Nailing layout and Semi Frameless Glass Panel Corner setout
Mountings 20 - 44 Shows Mounting details - For Timber, Concrete and Steel
Design, Wind 45 - 48 Shows all engineered Post spacing and Height maximums for various Mount and Wind factors
Design Details,Connections
49 - 51 Shows General Connection details. Handrails, Bottom Rail and Base Plates 60mm Slat - Split Rail. Handrail + Top and Bottom Rail. Face Fix
Design Details,Set outs for all Glass types
52 - 60 All 6mm Glass. Fully Framed and Full height. All with Handrails
61 - 63 All 8mm Glass. Semi Frameless with Handrails
64 - 69 All 10mm Glass. Semi Frameless with Handrails
70 - 72 All 13.2 Laminated Glass. Semi Frameless
73 - 78 All 17mm Baluster. Full Height and Split Rail. All with Handrails
79 - 84 All 60mm Slat Baluster. Full Height and Split Rail. All with Handrails
Design Details, Corners 85 Shows recommended 90 deg setouts for Solid balusters.
Floating Deck - Edge 86 Shows details of Floating Deck edge treatment to hide edge of deck
Surface Care 87 - 88 Instructions for the care of Powder coated and Glass surfaces
®Juralco EDGE Balustrade Systems
Complies With AS/NZS 1170:2002, NZS 4223.3.2016, NZ Building Code B1, B2, F2 ,F4 and F9Complies with French Standard NF P01-013 (1988-08)
Code Type of Occupancy for part of the building or structure
Specific Uses Glass
A Domestic and Residential activities All areas within or serving exclusively one dwelling including stairs, landings etc, but excluding external balconies and edges of roofs. 6mm,8mm and 10mm
Toughened Glass and 13.2mm Laminated Glass
A Other,C3
Areas without obstacles for moving people and not susceptible to over
crowding
Stairs, landings, external balconies, edges of roofs etc.
®EDGE Balustrade is for Domestic and Residential Occupancy types A, A Other and C3 onlyOccupancy Types as per AS/NZ 1170.1.2002. Not suitable for Commercial C3 applications
Glass 6mm, 8mm, 10mm Toughened Safety Glass and 13.2mm Toughened Laminated Safety Glass
Glass must have a minimum strength of 100MPa. All edges polished.
Juralco Balustrade Systems building code compliance documentation requires all balustrade installations
are to be completed in accordance with the requirements of our authorised installer certification.
Note 2
Note 1
Note 3 All Semi Frameless glass Balustrades must have an Top or Side mounted Handrail to conform to
NZS 4223.3.2016. Not necessary for Swimming Pools.
Index Section 4852JB
BA LU S T R A D E S YS T E M S
Page 4
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Specifications, Powder Coating
Juralco Aluminium Building Products Ltd (JABP)
Specifications for Juralco E Balustrade System®DGE
1.Scope
- This specification details the documents the Juralco EDGE Balustrade System refers to in relation to the New Zealand ®
Building Code, the manufacturer's documents, products used in the System, requirements in relation to fixing and surface
finishings.
2. NZBC Compliance
- The Juralco EDGE Balustrade System has been tested by Nancekivell Cairn Ltd, Civil and Structural Engineers, ®
to demonstrate compliance with the structural requirements of the New Zealand Building Code and AS/NZS 1170 : 2002
occupancy A, A Other and C3, NZS 3604 Low, Medium, High, Very High Wind Zone, max design wind pressure 2.0KPa
- The Structural Engineering design includes the requirements of B1 Structure, B2 Durability, F2 Hazardous material
and F4 Safety from falling, all from the Building Code.
- Verification Method B1 / VM1, B2/AS1, F4 / AS1.
- All glass used in the Juralco EDGE Balustrade System must conform to AS/NZS 2208.®
- Complies with NZS 4223.3.2016
3. Manufacturer's Documents
- The Juralco EDGE Balustrade System manual details all extrusions and components used for the fabrication and ®
installation/fixing of the system.
- A Producer Statement 1(Design) is available.
Copies of the above documents are available from:
Juralco Aluminium Building Products Ltd
48 Bruce McLaren Rd, Henderson, Auckland
Phone 09 478 8018 Fax 09 478 7883 Email specify@juralco.co.nz
- Any deviation from the standard fabrication or installation/fixing must be accompanied by a site specific PS1
with site specific calculations and drawings
4. Products
- Only extrusions, components and hardware supplied by or specified by JABP may be used in the Juralco EDGE System®
- Aluminium extrusions, components and hardware – unless specified are manufactured to 6060 T5 specifications
- Stainless Steel components, hardware, fixings – all components to 316 grade
- Glass - all glass used in the Juralco EDGE Balustrade System must conform to the specifications as listed in the ®
Juralco EDGE manual with each panel conforming to AS/NZS 2208 as confirmed by the Safety Stamp detailing the ®
manufacturer's description and licence number.
5.Surface Finishing
- Juralco Aluminium Building Products Ltd is a Dulux Registered Applicator site, registration number 2101.
JABP uses only Dulux branded powder coating materials® - Unless specified otherwise, Dulux Duralloy powder coating systems are used for properties greater than 100
metres from high tide level where AAMA 2603 performance is required® - Dulux Duratec powder coating systems must be used for all properties greater than 10 metres and up to 100
metres from high tide level where AAMA 2604 performance is required® ® - Dulux Duralloy has a 10 year film and colour integrity warranty, Dulux Duratec has a 20 year film and colour
integrity warranty
6. Installation and Fixing
- The Juralco EDGE Balustrade System must only be installed in accordance with the Juralco EDGE Balustrade ® ®
System manual
- Any deviation from that specified in the Juralco EDGE manual must only be in accordance with the site specific PS1 with ®
site specific calculations and drawings listing the non standard details
- The Juralco Balustrade System must only be fabricated/installed by a Juralco approved fabricator®EDGE
- Upon completion of the installation the fabricator must supply the owner with a PS3 (Construction)
Important instructions for Powder Coatings near Salt WaterThe standard Dulux powder coating system used by Juralco is Duralloy and is suitable for installations greater than 100 metres from high tide level®
and for buildings up to 3 stories above ground. Use Duratec for installations between 10 and 100 metres from high tide level and for prestigious ®
residential and commercial developments. For all other applications contact Juralco for alternative systems.Note - Powder coated prices listed in Juralco price books are for the standard Duralloy system. If the Duratec system is required it ® ®
must be specified upon placement of the order and will incur a surcharge – Duratec prices on application.®
lmportant instructions for Powder Coating - Attachment to structuresAn EPDM or similar material spacer must be used to separate powder coated aluminium items from all timber, concrete and steel structures.Failure to do so can lead to the chemicals in the structure affecting the powder coating layer on the aluminium.
Powder Coating WarrantyThe Dulux powder coating warranty period is conditional upon being maintained in accordance with the Dulux ‘Care and Maintenance Instructions’.Contact your installer for a copy (or download from Dulux) of the Care and Maintenance instructions or refer to the back page of this manual.
BA LU S T R A D E S YS T E M S
Page 5
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
6mm Glass, Inline - Full Height. Handrail + Split Rails.
For 6mm Toughened Glass
For 8mm Toughened Glass
Face FixGutter Brkt Face FixTop Mount
Face FixTop Mount
Face FixTop Mount
Face FixTop Mount
Gutter Brkt Face Fix
Gutter Brkt Face Fix
Gutter Brkt Face Fix
®Juralco EDGE Balustrade Systems - Typical Configurations
6mm Glass, Inline - Fully Framed. Handrail + Bottom Rail.
6mm Glass, Inline - Full Height. Handrail + Bottom Rail.
8mm Glass, Inline - Semi Frameless. Handrail.
Balustrade Height
Balustrade Height
Balustrade Height
Balustrade Height
BA LU S T R A D E S YS T E M S
Page 6
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
10mm Toughened Glass, Inline - Semi Frameless - JEB 222 Interlinking Rail + JEC 29 Brackets, Deck side.
For 10mm Toughened Glass - Conforms to NZS 4223.3.2016
A Corner Post is available for 10mm Glass, Inline - Semi Frameless. Top Mount only
Face FixTop Mount Gutter Brkt Face Fix
10mm Toughened Glass, Inline - Semi Frameless - Handrail
®Juralco EDGE Balustrade Systems - Typical Configurations
Balustrade Height
Face FixTop Mount Gutter Brkt Face Fix
Balustrade Height
10mm Toughened Glass - Semi Frameless - No Handrail. SWIMMING POOLS ONLY. 1200mm Min Height
Face FixTop Mount Gutter Brkt Face Fix
Balustrade Height
Required Barrier Height,1000mm
13.2mm Toughened Laminated Glass, Inline - Semi Frameless
Face FixTop Mount Gutter Brkt Face Fix
Balustrade Height
For 13.2mm Toughened Laminated Glass - Conforms to NZS 4223.3.2016, Section 22.4.3(b)
Top Protection cap JET 212 highly recommendedTop Protection cap JET 212 highly recommended
BA LU S T R A D E S YS T E M S
Page 7
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Interlinking Rail End CapPart No JEC 18
Can be used as RH or LH
27.5
INTERLINKING RAILPart No JEB/222/5.8
60.0
15
Front/Outside
Required Barrier height above Deck, 1000mm= Post height = Balustrade height above Deck
®Juralco EDGE Balustrade System
Interlinking Rail conforming to NZS 4223.3.2016 and Building Code Clause B1.3.4
Interlinking Rail End Cap, Straight
135 deg and 90deg corners
Interlinking Rail End CapCan be used as RH or LH
100 98
67.5
All ex 3mm Aluminium Plate
Joiners:- With Joiner in place, spot drill from below for position- Drill out joiner to 3mm dia, extrusion to 4mm dia- Use No 6 x 1/4in SS ST Pan sq drive screw- Insert dobs of V60 Silicone inside cavities before inserting- Both ends to be attached.- Joins must be within 300mm of Post- Minimum distance between screw and end of handrail is 10mm
17.5 bar
14 barV60 Silicone
17.5mm, 90degCorner Joiner Part No JEC 35
17.5mm, 135deg Corner Joiner Part No JEC 37
100 95
64
14mm, 90deg Corner Joiner Part No JEC 34
14mm, 135deg Corner Joiner Part No JEC 36
14mmStraight Joiner Part No JEC 32
17.5mmStraight Joiner Part No JEC 33
10mm Toughened Glass - Semi Frameless - Interlinking Rail + JEC 29 Brackets, Deck side.
Front/Outside
JEC 29 Hand Rail Brktand JEB/222
Interlinking Rail
Required Barrier Heightabove Deck, 1000mm
Glass Panel to Top of PostGlass Panel above Top of Post
50
61
Balustrade height above Deck
Post Height = Balustrade height above Deck-121mm
JEC 29 Hand Rail Brktand JEB/222
Interlinking Rail
BA LU S T R A D E S YS T E M S
Page 8
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Typical Configurations
For 17mm Baluster
17mm Baluster - Full Height. Handrail + Bottom Rail.
17mm Baluster - Split Rail. Handrail + Top and Bottom Rail.
60mm Slat - Full Height. Handrail + Bottom Rail.
60mm Slat - Split Rail. Handrail + Top and Bottom Rail.
For 60mm Baluster
Face FixTop Mount
Face FixTop Mount
Face FixTop Mount
Face FixTop Mount
Gutter Brkt Face Fix
Gutter Brkt Face Fix
Gutter Brkt Face Fix
Gutter Brkt Face Fix
Balustrade Height
Balustrade Height
Balustrade Height
Balustrade Height
Balustrade Height
BA LU S T R A D E S YS T E M S
Page 9
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Extrusions
FACE FIX EDGE POST Part No JEB/208/5
65.0
45.0
45.0
65.0
FACE FIX EDGE POSTSEMIFRAMELESS Part No JEB/214/5
TOP FIX EDGE POST SEMIFRAMELESSPart No JEB/212/5
65.0
45.0
17.1
TOP FIX EDGE POST Part No JEB/207/5
65.0
45.0
17.1
TOP FIX EDGE CORNER POST SEMIFRAMELESSPart No JEB/213/5
65.0
65.0
FACE FIX EDGE POSTSTIFFENER
Part No JEB/205/5
40.4
37.6
BA LU S T R A D E S YS T E M S
Page 10
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
14.6
20.6
14.6
20.6
POST FACE FIX INFILL CLIPPart No JEB/203/5
10.3
30.4
®Juralco EDGE Balustrade Systems - Extrusions
AEROFOIL HANDRAILPart No JEB/217/5.8
AEROFOIL HANDRAIL - TWIN POCKETPart No JEB/219/5.8
RECTANGULAR HANDRAILPart No JEB/216/5.8
ROUND HANDRAILPart No JEB/209/5.8
75.0
100.0
47.5
47.5
47.5
60.0
54.0
STANDARD INFILL CLIPPart No JEB/206/5.8
REBATED INFILL CLIPPart No JEB/218/5.8
Note - Infill clips are not used with the JEB 222
27.5
INTERLINKING RAILPart No JEB/222/5.8
60.0
15
BA LU S T R A D E S YS T E M S
Page 11
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
56.5
INFILL60mm SLAT
Part No JVB/019/5.3
60.0
INFILL17mm BALUSTER
Part No JVB/005/5.3
17.0
®Juralco EDGE Balustrade Systems - Extrusions
34.0
3.0
25.0
3.0
25x3 FLAT BAR HANDRAIL JOINTER
Part No JA174/5
FACE FIX SPACERPart No JVB 125/1000
11.0 dia
38.0 dia
BOTTOM RAILPart No JEB/202/5.8
34x3 FLAT BAR HANDRAIL JOINTER
Part No JA188/5
56.5x3 FLAT BAR HANDRAIL JOINTER
Part No JA189/5
BOTTOM RAIL SPIGOTPart No JEB/210/5
17.0
13.0
3.0
17.0
17.0
WATER DEFLECTION ANGLEPart No JA 118/5
20
20
INFILL123mm SLATPart No 2227
123
17
36.0
32.0
TOP PROTECTION CAPfor 13.2mm Laminated Glass
Part No JET 212(attach with JET 330
DS Tape)
20
6
13.8
INFILL49mm SLAT
Part No JVB/018/5.3
49.0
17.0
BA LU S T R A D E S YS T E M S
Page 12
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Post/Baseplate ScrewPart No JVBHTSCREW/50x10
50mm SS HT PK C/S sq drive screw
Base plate Part No JEC 200
110mm x 100mm x 12mm - 4 x holes
Base plate Part No JEC 221
110mm x 90mm x 12mm - 4 x holes
Front -110mm side
45mm x 65mm - Fits under face Fix PostsAttach with No 6 x 12 C/S SS PK screws
Face Fix SpacerPart No JVB 125/30mm
Face Fix SpacerPart No JVB 125/10mm
EPDM Spacer WasherPart No JVB 126
38mm dia x 30mm long. 38mm dia x 10mm long. 38mm dia x 3mm
Square WasherPart No JVB SQWSH
40mm sqx 3mm SS
Face Fix
Face Fix Face Fix Face Fix
Post Bottom CapPart No JEC 10HF
Hidden FixEPDM Washer
Part No JEC14GWASHER
11mm dia x 14g
Use with JESCREW 14g to attachPost cap to Post top
Base plate - Corner Post Part No JEC 222
110mm x 110mm x 12mm - 4 x holes x 14mm dia
Base plate Part No JEC 137/65
120mm wide x 135mm high - 4 x holes
®Juralco EDGE Balustrade Systems - Components
128mm x 80mm x 12mm - 2 x C/S holes 14mm dia
Base plate Part No JEC 231
For Poolsonly
Front -128mm side
Base plate Part No JEC 201
110mm x 90mm x 12mm - 2 x holes
For Concrete and Steel only
Handrail Clamp ScrewPart No JEC Screw M8x20
M8 x 20 SS Grub screw
HandrailClamp
Front -110mm side
Front -110mm side
135mm x 120mm x 5mm thick
Gutter Bracket SpacerPart No JEC 139
BA LU S T R A D E S YS T E M S
Page 13
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Top CapPart No JEC 20
Fits over Post. 66mm x 46mm
Top CapPart No JEC 21
Double PocketFits over Post. 66mm x 46mm
Top CapPart No JEC 22
Single Pocket. RH/LH symmetricalFits over Post. 66mm x 46mm
Handrail MountPart No JEC 23
Angled Hand Rail Mount - Double Pocket Fits over Post. 66mm x 46mm
Handrail MountPart No JEC 24
Handrail MountPart No JEC 25RH or LH
Angled Hand Rail Mount - No Pocket Fits over Post. 66mm x 46mm
Angled Hand Rail Mount - Single Pocket, LH & RH Fits over Post. 66mm x 46mm
RH version
FrontsideFrontside
Frontside
Frontside
Post Handrail ScrewPart No JEC Screw 14gx2
14g x 50mm SS PK Cap screw
Attach PostCapto Post top
Top Cap - Corner PostPart No JEC 27
Fits over Post. 66mm x 66mm
Top Cap Notched - Corner PostPart No JEC 28
Double PocketFits over Post. 66mm x 66mm
Use with to attachJEC14GWASHERPost cap to Post top
Handrail assemblyPart No JEC 29/Kit
Includes 2 x grub screws
Single sided 100mm wide x 15.2mt Roll
Foam Tape 100mm x 4.8mmPart No JVB/FTAPE100
Base PlateSeparator forConcrete, Steeland Timber
Foam Tape 38mm x 4.8mmPart No JVB/FTAPE38
Face fix PostSeparator forConcrete, Steeland Timber
Single sided 38mm wide x 15.2mt Roll
Corner Post, Handrail MountlPart No JEC 30
No Pockets - Fits over Post. 66mm x 66mm Pockets - Fits over Post. 66mm x 66mm
Corner Post, Handrail MountPart No JEC 31
®Juralco EDGE Balustrade Systems - Components
DS Tape 12.7mm x 0.8mmPart No JET 330
Attach TopProtectionCap
Double sided 12.7mm wide x 33mt Roll
For Wall or Post mounting
LH version
BA LU S T R A D E S YS T E M S
Page 14
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Components
For 10mmGlass
For 8mmGlass and13.2mmLaminatedGlass
For 6mmGlass
3mm Glazing WedgePart No JEC W10/100
100mt Roll - PVC
5mm Glazing WedgePart No JEC W8/75
7mm Glazing WedgePart No JEC W6/75
75mt Roll - PVC 75mt Roll - PVC
Glass Support BracketPart No JEC 13
17mm x 13mm x 32mm long. Attaches to Postwith 2 x No 8 x 16 SS PK Screws
Nylon
50mm Glazing BlockPart No JEC 15
5mm high x 16.5mm x 50mm long.
Glazing D SealPart No JECDSEAL/100
8mm deep x 9.5mm wide x 100mt RollSemi Rigid PVC
Glass Clamp ScrewPart No JVBHTSCREW/50x10
50mm SS HT PK C/S sq drive screw
Attach Clampto Post
13.5
52
35
Part No ThicknessH/PP1.5 1.5mmH/PP2 2mmH/PP3 3mmH/PP4 4mmH/PP5 5mm
Plastic Packer - Glass
Cut down to suit. 35x13.5, 52x13.5
Bottom Rail BracketPart No JEC 14
AttachesBottom Rail to Timber
Bottom Rail 90 deg SpigotPart No JEC 12
Joins BottomRail at90 deg
50mm x 38mm x 3mm thick. 76mm x 76mm.
SIKA Supergrip 2hrPart No JEC SUPERGRIP
For All Coachscrews fixings
Rhodorsil V60 Clear SiliconePart No H/RTV419098
Construction Silicone
Back SealPart No JET/BSEAL/100
For 13.2mmLaminatedGlass
BA LU S T R A D E S YS T E M S
Page 15
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
75mm Aerofoil End CapPart No JEC 11
Available as RH or LH
®Juralco EDGE Balustrade Systems - Components
100mm Aerofoil Handrail End CapStraight and 90deg corners
All ex 3mm Aluminium
Rectangular Handrails and 75mm Aerofoil - End Cap,Straight and 90deg corners
Round Handrails, End Cap,Straight and 90deg corners
100mm Aerofoil End CapPart No JEC 09
Available as RH or LH
Rectangular End CapPart No JEC 03
Can be used as RH or LH
Round End CapPart No JEC 06
Can be used as RH or LH
100mm Aerofoil Inline Joiner Use 25.0 x 3 flat bar JA/174/5
100mm Aerofoil 90deg Corner Joiner Part No JEC 07
Rectangular and 75m Aerofoil Inline Joiner Use 56.5 x 3 flat bar JA/189/5.0
Round Inline Joiner Use 34.0 x 3 flat bar JA/188/5.0
Rectangular and 75m Aerofoil90deg Corner Joiner Part No JEC 01
Round 90deg Corner Joiner Part No JEC 04
150
150
100
100
100
150
Interlinking Rail End Cap, Straight
135 deg and 90deg corners
Interlinking Rail End CapPart No JEC 18
Can be used as RH or LH 14mm, 90deg Corner Joiner Part No JEC 34
100
14mmStraight Joiner Part No JEC 32
14mm, 135deg Corner Joiner Part No JEC 36
17.5mm, 90degCorner Joiner Part No JEC 35
17.5mmStraight Joiner Part No JEC 33
17.5mm, 135deg Corner Joiner Part No JEC 37
100 9895
64 67.5
All ex 3mm Aluminium
All ex 3mm Aluminium
All ex 3mm Aluminium Plate
17.5 bar
14 bar
Notes:- One end must be rivetted in place.- Joins must be within 300mm of Post
BA LU S T R A D E S YS T E M S
Page 16
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Handrail Bracket
HANDRAIL BRACKET and WALL CLIPPart No JEC 29/Kit
Includes all above (not wall fix screws)
Attach Clip
Attach Clip
Grub Screw Clamp M5
Grub Screw Clamp M8x20
Hand rail bracket and Hand rails
Hand rail bracket and Hand rail.Angle attach up to 30deg
100
115
Wall or Balustrade Post
Hand rail bracket and Hand rail end
Chamfer end of Rib
75
34
60
45
54
47
Conforms toNZBC D1/AS1Access Routes
AEROFOIL HANDRAILPart No JEB/217/5.8
RECTANGULAR HANDRAILPart No JEB/216/5.8
ROUND HANDRAILPart No JEB/209/5.8
End Cap
60
45
INTERLINKING RAILPart No JEB/222/5.8
Attach with Post/Baseplate ScrewPart No JVBHTSCREW/50x10
BA LU S T R A D E S YS T E M S
Page 17
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Typical Post Mount Configurations
Top MountConcrete only.
Post cemented permanently in place
Top MountBase Plates in a variety
of sizes. Different fasteners typesdepending on the Building substrate.
Includes a 90deg Semi Frameless Corner Post
Face Fixed All hidden fasteners.
Different fasteners typesdepending on the Building
substrate
Gutter Bracket - Face Fixed Very suitable for Waterproofed Decks and
any overhanging decks.Allows for Guttering to run under.
Different fasteners types depending on the Building substrate
Note - For all Face Fix, there must be a Rubber or EDPM membrane between post and structure
Bond all coachscrews with SIKA Supergrip to full depth
Gutter Bracket and Base plate attach screws. JVBHTSCREW/50x10
Gutter Bracket and Base plate attach screws. JVBHTSCREW/50x10
Coachscrew, Bolt or Threaded Rod. All M10SS
with 21 dia SS washers
Coachscrew, Bolt or Threaded Rod. All M10SS
with 40 sq SS washers
Coachscrew, Bolt orThreaded Rod. All M10SSwith 21dia SS washers
Gutter Bracket Spacer, 5mmUse as required
BA LU S T R A D E S YS T E M S
Page 18
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical Double Boundary Joist Timber Deck Construction DetailsAlternative Solution to NZS 3604:2011 Clause 7.4.1.3detailed to resist twisting of the Boundary Joist only.
Deck designer to ensure the structure can support the appropriate horizontal and vertical loads.
1
All joists @400mm crs
All nogs @400mm crs
Joist off cut x 150mm
2
32
Pairs of Lumberlok Cleats CPC40SS
Attaching Joists or Nogs to Double Boundary Joist.
4 x cleats to each joist or nog,
Attaching Nogs to Joist.
2 x cleats to each nog, 1 x Joist offcut x 150mm
All Screwing to Joists, Nogs
Pairs of Lumberlok CPC40 SS Cleatseach side .All screws 304SS
Cleats to be flush,Top and Bottom
3 x Type 17 - 14g x 35 Hex head Screws
2 x Type 17 - 14g
x 75 Hex head Screws
This Glass Panelapprox 300mm wide
Gutter BracketMount at Corner
This Glass Panel
approx310mm wide
Rhodorsil V60Post Full Height
Single Lumberlok Cleats CPC40SS
Rhodorsil V60 Joint Full Height
At each Joist, nog.4 x 90mm nailsto both joists= 8 total
Between Joist, nogs.5 x 90mm nailsin two rows= 10 total
All Nailing
Typical EDGE Semiframeless Glass Corners
Distance to firstscrew approx 100mm
Corner.Lumberlok 0.9x19mm SS Strap.Wrapped around return boundary joistand nailed top and bottom with6x30mx3.15 SS Product nails at ea end
Face FixMount at Corner
This Glass Panelapprox 200mm wide
This Glass Panel
approx220mm wide
Rhodorsil V60Post Full Height
Rhodorsil V60 Joint Full Height
Distance to firstscrew approx 100mm
All Screwing to Corners
Pair of Lumberlok CPC80 SS CleatsAll screws 304SS
Cleats to be flush,Top and Bottom
8 x Type 17 - 14g x 35 Hex head Screws
4 x Type 17 - 14g
x 75 Hex head Screws
Attaching Corner of Double Boundary Joist
2 x cleats to Corner and Lumberlok strap
All Nailing
Corner.4 x 90mm nailsto both joists= 12 total
This page - applies to FACE FIX only
13
2
Lumberlok SS
Strap 0.9x19.
6 x 30x3015
Nails ea end
Please noteJoist overlaparrangement
All Fasteners must be Stainless Steel
All Fasteners must be Stainless Steel All Fasteners must be Stainless Steel
BA LU S T R A D E S YS T E M S
Page 19
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical Double Boundary Joist Timber Deck Construction DetailsAlternative Solution to NZS 3604:2011 Clause 7.4.1.3detailed to resist twisting of the Boundary Joist only.
Deck designer to ensure the structure can support the appropriate horizontal and vertical loads.
1
All joists@400mm crs
All nogs @400mm crs
Joist off cut x 150mm
2
32
Pairs of Lumberlok Cleats CPC40SS
Single Lumberlok Cleats CPC40SS
Beside each Joist, nog.4 x 14gx90mm screwsto both joists= 8 total
Screwing Screwing
Corner.Pairs of 14gx100screws= 8 total
This page - applies to TOP FIX only
All Screwing to Joists, Nogs
Pairs of Lumberlok CPC40 SS Cleatseach side .All screws 304SS
Cleats to be flush,Top and Bottom
3 x Type 17 - 14g x 35 Hex head Screws
2 x Type 17 - 14g
x 75 Hex head Screws
Attaching Joists or Nogs to Double Boundary Joist.
4 x cleats to each joist or nog,
Attaching Nogs to Joist.
2 x cleats to each nog, 1 x Joist offcut x 150mm3
2
Pairs of 14g x 100 screws (= 8 total)
Nailings 90x3.153x 3 = 9 total @ 40mm spacingsThis side only
Screwing and Bolting at Corner
Steel BracketBS 176 for 200mm deep joistsBS 177 for 250mm deep joists
Pairs of M12 x bolts and washers(= 4 total)Hex head or C/S
Boundary Joists at Corner.
Bracket and M12 Bolt fixings
4 x M10 x 160 (min) + Decking SS Coachscrews and 21mm dia SS Washers
Boundary Joists at Corner.
14g screw fixing
Boundary Joists at Corner.
Balustrade cornerplate fixing
Please noteJoist overlaparrangement
BoltingCorner.Steel Bracket + 4 x M12 SS BoltsBS 176 for 200mm deep joistsBS 177 for 250mm deep joists
1
1
All Fasteners must be Stainless Steel
All Fasteners must be Stainless Steel All Fasteners must be Stainless Steel
BA LU S T R A D E S YS T E M S
Page 20
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Decking
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
Typical TOP Fix to Timber - JEC 221, 110mm x 90mm, 4 hole Base Plate - M10 Coachscrews
Base Plate
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
4 x M10 x 160 (min) + Decking SS Coachscrews and 21mm dia SS Washers
Post
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - Coachscrews 150mm min engagement into joists
4 - Bond all coachscrews with SIKA Supergrip to full depth
5 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
6 - All screw fixings must be Stainless steel
Double Boundary Joist
CPC 40 SS Cleats
BA LU S T R A D E S YS T E M S
Page 21
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Decking
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
105
25
Typical FACE Fix to Timber - JEC 137/65, Gutter Bracket - M10 Coachscrews
EPDMor Foam Tape
38
4 x M10 x 110 (min) SS Coachscrews and 21mm dia SS Washers
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - Coachscrews 90mm min engagement into joists
4 - Bond all coachscrews with SIKA Supergrip to full depth
5 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber.
6 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
7 - All screw fixings must be Stainless steel
Post
Gutter Bracket Spacer, 5mmUse as required
Guttering - Runs under the JEC137/65 Gutter Bracket.Attached separately either sideof the JEC137/65 to suit proprietyguttering systems. Pack out to clear bracket.
Double Boundary Joist
CPC 40 SS Cleats
51
BA LU S T R A D E S YS T E M S
Page 22
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Decking
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
105
25
Typical FACE Fix to Timber - JEC 137/65, Gutter Bracket - M10 Bolts or Threaded Rod
38
EPDMor Foam Tape
4 x M10 SS Bolts and 21mm dia SS Washers(or M10 SS threaded rod with dome nuts)
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Post
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber
4 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
5 - All screw fixings must be Stainless steel
Gutter Bracket Spacer, 5mmUse as required
Guttering - Runs under the JEC137/65 Gutter Bracket.Attached separately either sideof the JEC137/65 to suit proprietyguttering systems. Pack out to clear bracket.
Double Boundary Joist
CPC 40 SS Cleats
51
BA LU S T R A D E S YS T E M S
Page 23
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
Batten and Cladding
Waterproof Decking
Building wrap
Cavity batten
Cladding
Apply sealant to all holes
105
25
Decking andWaterproof membrane 5
Angle 20x20x3Screw attached tounderside
Typical FACE Fix to Waterproof Timber Deck - JEC 137/65, Gutter Bracket - M10 Coachscrews
Alternative solution E2/AS1
38
EPDMor Foam Tape
4 x M10 x 110 (min) + Cladding SS Coachscrews and 21mm dia SS Washers
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Post
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - Coachscrews 90mm min engagement into joists
4 - Bond all coachscrews with SIKA Supergrip to full depth
5 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber.
6 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
7 - All screw fixings must be Stainless steel
Gutter Bracket Spacer, 5mmUse as required
Guttering - Runs under the JEC137/65 Gutter Bracket.Attached separately either sideof the JEC137/65 to suit proprietyguttering systems. Pack out to clear bracket.
Double Boundary Joist
CPC 40 SS Cleats
51
BA LU S T R A D E S YS T E M S
Page 24
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Decking
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
145min
25
150 min
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Post stiffener
Face Fix infill clip JEB/203/5
Typical FACE Fix Post to Timber - M10 Coachscrews
EPDMor Foam Tape
2 x M10 x 140 (min) SS Coachscrewsand 40sq SS Washers
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
Post
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - Coachscrews 90mm min engagement into joists
4 - Bond all coachscrews with SIKA Supergrip to full depth
5 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber.
6 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
7 - All screw fixings must be Stainless steel
Double Boundary Joist
CPC 40 SS Cleats
BA LU S T R A D E S YS T E M S
Page 25
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Decking
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
2 x M10 SS Bolts (or M10 SS threaded rod with dome nuts) and 40sq SS Washers
Face Fix infill clip JEB/203/5
Post stiffener
95min
25
150 min
Typical FACE Fix Post to Timber - M10 Bolts or Threaded Rod
EPDMor Foam Tape
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Post
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Post and Timber
4 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
5 - All screw fixings must be Stainless steel
Double Boundary Joist
CPC 40 SS Cleats
BA LU S T R A D E S YS T E M S
Page 26
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
MinimumJoist or Nog size
ex 200mm x 50mm
Top and Bottom, both sides of every joist or nog = 4 x Lumberlok CPC40 Stainless Steel cleats.
with 2 x Type 17 - 14g x 75 Hex head Screws to Boundary joistsand with 3 x Type 17 - 14g x 35 Hex head Screws to Deck joist
for every cleat
145min
25
150 min
Building wrap
Cavity batten
Cladding
Apply sealant to all holes
Waterproof Decking
EPDM washers JVB 126
Spacers JVB 125
Spacer and EPDM Washer
Typical FACE Fix Post to Waterproof Timber Deck - M10 Coachscrews and Spacers
Decking andWaterproof membrane
®Juralco EDGE Balustrade Systems - Typical Post Fixings
- Double Boundary Joists NZS3604:2011 Type Connection
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
Note : As the Juralco EDGE System is aSpecifically Engineered Designed systemit does not require M12 bolts at400mm centresas detailed in NZS 3604:2011 Section 7
Face fix post Stiffenerto extend from bottom to150mm min above top anchor
Face Fixinfill clip JEB/203/5
2 x M10 x 200 (min) + Cladding +Spacers SS Coachscrews and 40sq SS Washers
Post
Batten and Cladding
Important notes:
1 - The Designer must ensure the structure can support the appropriate horizontal and vertical loads
2 - Please refer to the Timber Deck Construction page for full nailing and screwing details.
3 - Coachscrews 90mm min engagement into joists
4 - Bond all coachscrews with SIKA Supergrip to full depth
5 - A EPDM washer must be installed between the Spacers and Timber.
6 - The Lumberlok cleats must be attached to every joist or nog under the Balustrade
Please refer to the Double Joist Nailing/Screwing setout page
7 - All screw fixings must be Stainless steel
Double Boundary Joist
CPC 40 SS Cleats
BA LU S T R A D E S YS T E M S
Page 27
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
X
Depth
Typical TOP Fix to Concrete - JEC 200, 110mm x 90mm, 4 hole Base Plate - M10 Anchors
Concrete Slab
EPDM or Foam Tape
®Juralco EDGE Balustrade Systems - Typical Post Fixings
Base Plate JEC 200
4 off M10 x 98 Hex Dynabolts, Stainless Steel. DP 12100SS
4 off M10 x 90 Chemset Anchors, Stainless Steel + Chemset capsule CS10130SS
X (min)
90mm
35mm
Depth (min)
75mm
90mm
Base Plate
Concrete slab
4 x M10 SS Dynaboltsor Chemical Fasteners
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - All fixings must engage into the structural slab
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Base plate and Concrete
4 - All fixings must be Stainless steel
Post
BA LU S T R A D E S YS T E M S
Page 28
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical TOP Fix to Concrete - JEC 201, 110mm x 90mm, 2 hole Base Plate - M12 Studs
Concrete Slab
Base Plate
2 x M12 SS Studs + Epcon C6and 21mm dia SS Washers
EPDM or Foam Tape
®Juralco EDGE Balustrade Systems - Typical Post Fixings
Base Plate JEC 201
2 off M12 SS Studs + Epcon C6
X (min)
60mm
Depth (min)
110mm
Concrete slab
X
Depth
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - All fixings must engage into the structural slab
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Base plate and Concrete
4 - All fixings must be Stainless steel
Post
BA LU S T R A D E S YS T E M S
Page 29
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical TOP Fix to Concrete - Embed Post in Concrete Slab
Concrete Slab
EPDM or Foam Tape
®Juralco EDGE Balustrade Systems - Typical Post Fixings
Concrete Type
Reinforced Slab
Y (min)
70mm
Depth (min)
95mm
Concrete slab Y
Depth
Reinforced concrete slab withD10 min Reinforcing along slab edge
with cross bracing
Mortar pocket 70mm sq or 85mm dia.Avoid motar splashes on exposed aluminium -
wash off immediatley.
End Cap JEC 10 HF
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - All fixings must engage into the structural slab
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Post and Concrete
4 - All fixings must be Stainless steel
Post
BA LU S T R A D E S YS T E M S
Page 30
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Decking
Base Plate
Typical TOP Fix to Steel with Timber Deck - JEC 221, 110mm x 90mm, 4 hole Base Plate - M10 Bolts
®Juralco EDGE Balustrade Systems - Typical Post Fixings
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate load
2 - All fixings must be Stainless steel
Post
Typical PFCFlange 90mm min
Web 6mm min
4 x M10 SS Boltsand 21mm dia SS Washers
BA LU S T R A D E S YS T E M S
Page 31
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical PFCWeb 6mm min
®Juralco EDGE Balustrade Systems - Typical Post Fixings
Decking
105
50 max
Typical FACE Fix to Steel - JEC 137/65, Gutter Bracket - M10 Bolts
EPDMor Foam Tape
38
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Steel
3 - All fixings must be Stainless steel
Post
Gutter Bracket Spacer, 5mmUse as required
Guttering - Runs under the JEC137/65 Gutter Bracket.Attached separately either sideof the JEC137/65 to suit proprietyguttering systems. Pack out to clear bracket.
4 x M10 SS Boltsand 21mm dia SS Washers
51
BA LU S T R A D E S YS T E M S
Page 32
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical PFCWeb 6mm min
Wooden Packers
®Juralco EDGE Balustrade Systems - Typical Post Fixings
Decking
105
50 max
Typical FACE Fix to Steel, Wooden Packers - JEC 137/65, Gutter Bracket - M10 Bolts
EPDMor Foam Tape
38
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Steel
3 - All fixings must be Stainless steel
Post
Gutter Bracket Spacer, 5mmUse as required
Guttering - Runs under the JEC137/65 Gutter Bracket.Attached separately either sideof the JEC137/65 to suit proprietyguttering systems. Pack out to clear bracket.
4 x M10 SS Boltsand 21mm dia SS Washers
51
BA LU S T R A D E S YS T E M S
Page 33
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Concrete Slab
Holes 12mm dia x 110mm deep min
90mm min to edge
®Juralco EDGE Balustrade Systems - Typical Post Fixings
105
35 min
175 min
110 minConcrete Slab
35 min
Typical FACE Fix to Concrete - JEC 137/65, Gutter Bracket - M10 Studs
EPDMor Foam Tape
38
4 x M10 SS Studs + Epcon C6 and 21mm dia SS Washers
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - All fixings must engage into the structural slab
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Concrete
4 - All fixings must be Stainless steel
Post
Gutter Bracket Spacer, 5mmUse as required
Guttering - Runs under the JEC137/65 Gutter Bracket.Attached separately either sideof the JEC137/65 to suit proprietyguttering systems. Pack out to clear bracket.
51
BA LU S T R A D E S YS T E M S
Page 34
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Typical Post Fixings
60 min
150 min
70 max
Decking
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
Typical FACE Fix Post to Steel - M10 Bolts
EPDMor Foam Tape
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - A Rubber, EPDM or Foam Tape layer must be installed between the Post and Steel
3 - All fixings must be Stainless steel
Post
Typical PFCWeb 6mm min
Face Fix infill clipJEB/203/5
PostStiffener
2 x M10 SS Boltsand 21mm dia SS Washers
BA LU S T R A D E S YS T E M S
Page 35
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical PFCWeb 6mm min
Wooden Packers
®Juralco EDGE Balustrade Systems - Typical Post Fixings
60 min
150 min
70 max
Decking
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
Typical FACE Fix Post to Steel, Wooden Packers - M10 Bolts
EPDMor Foam Tape
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - A Rubber, EPDM or Foam Tape layer must be installed between the Post and Steel
3 - All fixings must be Stainless steel
Post
PostStiffener
Face Fix infill clipJEB/203/5
2 x M10 SS Boltsand 21mm dia SS Washers
BA LU S T R A D E S YS T E M S
Page 36
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Concrete Slab
Holes 12mm dia x 110mm deep min
90mm min to edge
®Juralco EDGE Balustrade Systems - Typical Post Fixings
60 min
35 min
Post stiffener
150 min
130 min
110 min
Concrete Slab
35 min
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
2 x M10 SS Studs + Epcon C6and 40sq SS Washers
Face Fix infill clipJEB/203/5.0
Typical FACE Fix Post to Concrete - M10 Studs
EPDMor Foam Tape
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - All fixings must engage into the structural slab
3 - A Rubber, EPDM or Foam Tape layer must be installed between the Postand Concrete
4 - All fixings must be Stainless steel
Post
BA LU S T R A D E S YS T E M S
Page 37
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Typical TOP Fix to Timber - JEC 200, 110mm x 100mm, 4 hole Base Plate - M10 Coachscrews or Bolts
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Solid Blockbetween Joists
For 150mm Joist - 4 x M 10 SS B olts, right through with nut & washer
For 200mm+ Joist - 4 x M10 SS Coachscrews, 20mm od x 11mm id washers.
Min 150mm into joist Base Plate
Decking
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Minimum Joist sizeex 150mm x 50mm (for M10 bolts)ex 200mm x 50mm (for M10 coachscrews)
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
Joist Hanger 190 SS (for 200 x 50) 120 SS (for 150 x 50)min 4 off No 6 x 35 screw fix to Boundary Joist12 x 3.15mm nails fix to joist
4 x M10 x 160 (min) + Decking SS Coachscrews and 21mm dia SS washers
(or 4 x M10 SS Bolts)
Decking
New 20mm Packer and Block,
Nails, 24 off 90 x 3.4mm dia through Block/Packer/Joist
ExistingBoundary Joist
New Solid Block and Packerbetween Joists
ExistingBoundary Joist
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - Coachscrews 150mm min engagement into joist and block
3 - Bond all coachscrews with SIKA Supergrip to full depth
4 - All fixings must be Stainless steel
Post
BA LU S T R A D E S YS T E M S
Page 38
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Typical TOP Fix to Timber - JEC 221, 110mm x 90mm, 4 hole Base Plate - M10 Coachscrews or Bolts
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
New Solid Blockbetween Joists
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
Solid Blockbetween Joists
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Base Plate
Decking
Nails, 24 off 90 x 3.4mm dia through Block/Joist
Minimum Joist sizeex 150mm x 50mm (for M10 bolts)ex 200mm x 50mm (for M10 coachscrews)
For 150mm Joist - 4 x M 10 SS B olts, right through with nut & washer
For 200mm+ Joist - 4 x M10 SS Coachscrews, 20mm od x 11mm id washers.
Min 150mm into joist
Joist Hanger 190 SS (for 200 x 50) 120 SS (for 150 x 50)min 4 off No 6 x 35 screw fix to Boundary joist12 x 3.15mm nails fix to joist
4 x M10 x 160 (min) + Decking SS Coachscrews and 21mm dia SS washers
(or 4 x M10 SS Bolts)
Decking
ExistingBoundary Joist
ExistingBoundary Joist
New Solid Blockbetween Joists
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - Coachscrews 150mm min engagement into joist and block
3 - Bond all coachscrews with SIKA Supergrip to full depth
4 - All fixings must be Stainless steel
Post
BA LU S T R A D E S YS T E M S
Page 39
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
New Solid Block between joists
105 Minimum Joist sizeex 200mm x 50mm
Joist Hanger x 190 SS min 4 off No6 x 35 screw fixto Boundary joist12 x 3.15mm nails fix to joist
25
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
Typical FACE Fix to Timber - JEC 137/65, Gutter Bracket - M10 Coachscrews
EPDMor Foam Tape
38
Nails, 24 off 90 x 3.4mm dia through Block/Joist
4 x M10 x 110 (min) SS Coachscrewsand 21mm dia SS washers
Decking
ExistingBoundary Joist
ExistingBoundary Joist
New Solid Blockbetween Joists
Decking
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Guttering - Runs under this bracket.Attached separately to boundary joists either side of the JEC137/65 tosuit propriety guttering systems. Pack outto clear bracket.
Guttering Attached separately to boundary joists either side of the JEC137/65 to suitpropriety guttering systems. Pack out to clear bracket.
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Solid Blockbetween Joists
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Gutter Bracket Spacer, 5mmUse as required
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - Coachscrews 90mm min engagement into joist and block
3 - Bond all coachscrews with SIKA Supergrip to full depth
4 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber
5 - All fixings must be Stainless steel
Post
51
BA LU S T R A D E S YS T E M S
Page 40
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
New Solid Block between joists
105 Minimum Joist sizeex 200mm x 50mm
25
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
Solid Blockbetween Joists
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Typical FACE Fix to Timber - JEC 137/65, Gutter Bracket - M10 Bolts or Threaded Rod
EPDMor Foam Tape
38
Nails, 24 off 90 x 3.4mm dia through Block/Joist
4 x M10 SS Bolts and 21mm dia SS washers(or M10 SS threaded rod with dome nuts)
Decking
ExistingBoundary Joist
New Solid Blockbetween Joists
ExistingBoundary JoistDecking
Joist Hanger x 190 SS min 4 off No6 x 35 screw fixto Boundary joist12 x 3.15mm nails fix to joist
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Guttering - Runs under this bracket.Attached separately to boundary joists either side of the JEC137/65 tosuit propriety guttering systems. Pack outto clear bracket.
Guttering Attached separately to boundary joists either side of the JEC137/65 to suitpropriety guttering systems. Pack out to clear bracket.
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Gutter Bracket Spacer, 5mmUse as required
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber.
3 - All fixings must be Stainless steel
Post
51
BA LU S T R A D E S YS T E M S
Page 41
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Decking andWaterproof membrane
105 Minimum Joist sizeex 200mm x 50mm
New Solid Block between joists
25
Waterproof Decking
Building wrap
Cavity batten
Cladding
Apply sealant to all holes
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
Solid Blockbetween Joists
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Typical FACE Fix to Waterproof Timber Deck - JEC 137/65, Gutter Bracket - M10 Coachscrews
Alternative solution E2/AS1
Angle 20x20x3Screw attached tounderside
5
EPDMor Foam Tape
38
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Nails, 20 off 100 x 4mm dia through Block/Joist
4 x M10 x 110 (min) + Cladding SS Coachscrews and 21mm dia SS washers
ExistingBoundary JoistNew Solid Block
between Joists
ExistingBoundary Joist
Joist Hanger x 190 SS min 4 off No6 x 35 screw fixto Boundary joist12 x 3.15mm nails fix to joist
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Guttering - Runs under this bracket.Attached separately to boundary joists either side of the JEC137/65 tosuit propriety guttering systems. Pack outto clear bracket.
Guttering Attached separately to boundary joists either side of the JEC137/65 to suitpropriety guttering systems. Pack out to clear bracket.
Gutter Bracket Spacer, 5mm Use as required
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - Coachscrews 90mm min engagement into joist and block
3 - Bond all coachscrews with SIKA Supergrip to full depth
4 - A Rubber, EPDM or Foam Tape layer must be installed between the Bracket and Timber.
5 - All fixings must be Stainless steel
Batten and Cladding
Post
51
BA LU S T R A D E S YS T E M S
Page 42
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
New Solid Block between joists
145min
25
150 min
Minimum Joist sizeex 200mm x 50mm
Post stiffener
Face Fix infill clip JEB/203/5
2 x M10 x 140mm (min) SS Coachscrews and 40sq SS washers
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
Solid Blockbetween Joists
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Typical FACE Fix Post to Timber - M10 Coachscrews
EPDMor Foam Tape
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Nails, 24 off 90 x 3.4mm dia through Block/Joist
Decking
ExistingBoundary JoistNew Solid Block
between Joists
Decking ExistingBoundary Joist
Joist Hanger x 190 SS min 4 off No6 x 35 screw fixto Boundary joist12 x 3.15mm nails fix to joist
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - Coachscrews 90mm min engagement into joist and block
3 - Bond all coachscrews with SIKA Supergrip to full depth
4 - A Rubber, EPDM or Foam Tape layer must be installed between the Post and Timber.
5 - All fixings must be Stainless steel
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Post
BA LU S T R A D E S YS T E M S
Page 43
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
95 min
25
150 min
Minimum Joist sizeex 150mm x 50mm
New Solid Block between joists
2 x M10 SS Bolts (or M10 SS threaded rod with dome nuts)and 40sq SS washers
New Solid Blockbetween Joists
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
Solid Blockbetween Joists
Face Fix infill clip JEB/203/5
Post stiffener
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Typical FACE Fix Post to Timber - M10 Bolts or Threaded Rod
EPDMor Foam Tape
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Nails, 24 off 90 x 3.4mm dia through Block/Joist
Decking
ExistingBoundary Joist
DeckingExistingBoundary Joist
Joist Hanger x 190 SS min 4 off No6 x 35 screw fixto Boundary joist12 x 3.15mm nails fix to joist
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - A Rubber, EPDM or Foam Tape layer must be installed between the Post and Timber
3 - All fixings must be Stainless steel
Face fix post Stiffenerto extend from bottom to
150mm min above top anchor
Post
BA LU S T R A D E S YS T E M S
Page 44
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Note - For Face Fix Infill clip.These clips to be machined off
for top 35mm, to provide clearance for Top Cap
145min
25
150 min
Minimum Joist sizeex 200mm x 50mm
New Solid Block between joists
Building wrap
Cavity batten
Cladding
Apply sealant to all holes
Waterproof Decking
Face Fix infill clip JEB/203/5
Spacerand EPDM Washer
Nail to front face of block before installing.Wrap around ends of block and extend along joist using 12 x 3.15dia nails.Line up straps with top/bottom edges.
Solid Blockbetween Joists
EPDM washers JVB 126
Spacers JVB 125
®Juralco EDGE Balustrade Systems - Typical Post Fixing
Pre NZS3604:2011 - Single Boundary Joist
4 x 53mm wide Lumberlok MultibraceStainless steel straps.
Typical FACE Fix Post to Waterproof Timber Deck - M10 Coachscrews and Spacers
Decking andWaterproof membrane
Nails, 20 off 100 x 4mm dia through Block/Joist
2 x M10 x 140 (min) + Cladding + Spacers SS Coachscrews and 40sq SS washers
ExistingBoundary Joist
New Solid Blockbetween Joists
ExistingBoundary Joist
Joist Hanger x 190 SS min 4 off No6 x 35 screw fixto Boundary joist12 x 3.15mm nails fix to joist
The pre NZS3604:2011 mounting details
are included for older, existing buildings.
New buildings must comply with
NZS3604:2011 - Double Boundary Joists
4 x 53mm wide Lumberlok MultibraceStainless steel straps.12 x 3.15mm nails to each end of each plate
Important notes:
1 - A Design engineer must ensure the structure can support the appropriate loads
2 - Coachscrews 90mm min engagement into joist and block
3 - Bond all coachscrews with SIKA Supergrip to full depth
4 - A Rubber, EPDM or Foam Tape layer must be installed between the Spacers and Timber.
5 - All fixings must be Stainless steel
Face fix post Stiffenerto extend from bottom to150mm min above top anchor
Post
Batten and Cladding
BA LU S T R A D E S YS T E M S
Page 45
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
NZS 3604 Low, Medium, High and Very High Wind Zones.Up to a max Design Wind Speed of 50m/sec but not exceedinga Design Wind Pressure of 1.5kPa. Occupancy for Domesticand Residential A, A Other and C3 only. AS/NZS1170
1000
1100
1200
1300
1400
200 400 600 800 1000 1200 1400 1600 1800
Balustrade Height(above Deck) mm
Post C/L Spacing mm
Group 1Group 2
Chart 1 - Residential Buildings, Offices and Work Areas. Up to 1.5kPa
Floating Decks - the distance between the top of the boundary joists and the top of the floating deck must be added to the post height. This will result in the post c/l spacing being reduced. A floating deck is not a structural item and cannot be used for the primary fixing of fasteners.
Group 1
Applies to Mountings
TOP Fix to Concrete - Baseplate JEC 200
TOP Fix to Concrete - Baseplate JEC 201
TOP Fix to Concrete - Embed Post in Concrete Slab
FACE Fix to Timber - Gutter Bracket - Coachscrews
FACE Fix to Timber - Gutter Bracket - Bolts
FACE Fix to Timber - Gutter Bracket - Water proofed Deck
FACE Fix to Steel - Gutter Bracket
FACE Fix to Steel + Wooden Packers - Gutter Bracket
FACE Fix to Concrete Slab - Gutter Bracket
FACE Fix Post to Steel
FACE Fix Post to Steel + Wooden Packers
FACE Fix Post to Concrete Slab
Group 2
Applies to Mountings
TOP Fix to Timber - Baseplate JEC 200
TOP Fix to Timber - Baseplate JEC 221
TOP Fix to Steel (with timber deck) - Baseplate JEC 221
FACE Fix Post to Timber - Coachscrews
FACE Fix Post to Timber - Bolts
FACE Fix Post to Waterproofed Timber Deck
1 - See Floating Deck comment below2 - See page 3 for Balustrade Height defined3 - Minimum Post height 760mm above deck to comply with ‘Toe hold’ requirements of F4/AS1
Design Wind Speed exceeding 50m/sec or a Design Wind Pressureexceeding 1.5kPa and up to a max Design Wind Pressure of 2.0kPa Occupancy for Domestic and Residential A, A Other and C3 only. AS/NZS1170
Chart 2 - Residential Buildings, Offices and Work Areas. Up to 2.0kPa
1000
1100
1200
1300
1400
200 400 600 800 1000 1200 1400 1600 1800
Post C/L Spacing mm
Group 1Group 2Balustrade Height(above Deck) mm
1 - See Floating Deck comment below2 - See page 3 for Balustrade Height defined3 - Minimum Post height 760mm above deck to comply with ‘Toe hold’ requirements of F4/AS1
Floating Decks - the distance between the top of the boundary joists and the top of the floating deck must be added to the post height. This will result in the post c/l spacing being reduced. A floating deck is not a structural item and cannot be used for the primary fixing of fasteners.
Group 1
Applies to Mountings
TOP Fix to Concrete - Baseplate JEC 200
TOP Fix to Concrete - Baseplate JEC 201
TOP Fix to Concrete - Embed Post in Concrete Slab
FACE Fix to Timber - Gutter Bracket - Coachscrews
FACE Fix to Timber - Gutter Bracket - Bolts
FACE Fix to Timber - Gutter Bracket - Water proofed Deck
FACE Fix to Steel - Gutter Bracket
FACE Fix to Concrete Slab - Gutter Bracket
FACE Fix Post to Steel
FACE Fix Post to Concrete Slab
Group 2
Applies to Mountings
TOP Fix to Timber - Baseplate JEC 200
TOP Fix to Timber - Baseplate JEC 221
TOP Fix to Steel (with timber deck) - Baseplate JEC 221
FACE Fix Post to Timber - Coachscrews
FACE Fix Post to Timber - Bolts
FACE Fix Post to Waterproofed Timber Deck
BA LU S T R A D E S YS T E M S
Page 46
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Chart 3 - Wind Breaks /Extended for Semi Frameless EDGE Balustrade - Up to 1.5kPa
NZS 3604 Low, Medium, High and Very High Wind Zones.Up to a max Design Wind Speed of 50m/sec but not exceeding a Design Wind Pressure of 1.5kPaOccupancy for Domestic and Residential A, A Other and C3 only. AS/NZS1170
Design Wind Speed exceeding 50m/sec or a Design Wind Pressure exceeding 1.5kPa and upto a max Design Wind Pressure of 2.0kPa. Occupancy for Domestic and Residential A, A Other and C3 only. AS/NZS1170
Chart 4 - Wind Breaks /Extended for Semi Frameless EDGE Balustrade - Up to 2.0kPa
500 1000 150001000
1100
1300
1400
1200
1500
1600
1700
1800
Post C/L Spacing mm
500 1000 150001000
1100
1300
1400
1200
1500
1600
1700
1800
Post C/L Spacing mm
Group 1Group 2
Group 1Group 2
Note - Coach Screws into Timber mustbe bonded with Sika Supergrip 2hr
Note - Coach Screws into Timber mustbe bonded with Sika Supergrip 2hr
Balustrade Height(above Deck) mm
Balustrade Height(above Deck) mm
Group 1
Applies to Mountings
TOP Fix to Concrete - Baseplate JEC 200
TOP Fix to Concrete - Baseplate JEC 201
TOP Fix to Concrete - Embed Post in Concrete Slab
FACE Fix to Timber - Gutter Bracket - Coachscrews
FACE Fix to Timber - Gutter Bracket - Bolts
FACE Fix to Timber - Gutter Bracket - Water proofed Deck
FACE Fix to Steel - Gutter Bracket
FACE Fix to Concrete Slab - Gutter Bracket
FACE Fix Post to Steel
FACE Fix Post to Concrete Slab
Group 2
Applies to Mountings
TOP Fix to Timber - Baseplate JEC 200
TOP Fix to Timber - Baseplate JEC 221
TOP Fix to Steel (with timber deck) - Baseplate JEC 221
FACE Fix Post to Timber - Coachscrews
FACE Fix Post to Timber - Bolts
FACE Fix Post to Waterproofed Timber Deck
Group 1
Applies to Mountings
TOP Fix to Concrete - Baseplate JEC 200
TOP Fix to Concrete - Baseplate JEC 201
TOP Fix to Concrete - Embed Post in Concrete Slab
FACE Fix to Timber - Gutter Bracket - Coachscrews
FACE Fix to Timber - Gutter Bracket - Bolts
FACE Fix to Timber - Gutter Bracket - Water proofed Deck
FACE Fix to Steel - Gutter Bracket
FACE Fix to Concrete Slab - Gutter Bracket
FACE Fix Post to Steel
FACE Fix Post to Concrete Slab
Group 2
Applies to Mountings
TOP Fix to Timber - Baseplate JEC 200
TOP Fix to Timber - Baseplate JEC 221
TOP Fix to Steel (with timber deck) - Baseplate JEC 221
FACE Fix Post to Timber - Coachscrews
FACE Fix Post to Timber - Bolts
FACE Fix Post to Waterproofed Timber Deck
BA LU S T R A D E S YS T E M S
Page 47
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Chart 5 - Free Standing Wind Breaks Not applicable to AS/NZS1170For low or no decks where safety from falling is not required
Wind Speeds
Low = Up to 0.73kPa
Medium = Up to 0.983kPa
High = Up to 1.39kPa
Very High = Up to 1.8kPa
Extra High = Up to 2.18kPa
Chart 6 - Free Standing Wind BreaksNot applicable to AS/NZS1170For low or no decks where safety from falling is not required
Wind Speeds
Low = Up to 0.73kPa
Medium = Up to 0.983kPa
High = Up to 1.39kPa
Very High = Up to 1.8kPa
Extra High = Up to 2.18kPa
500 1000 1500 200001400
1600
1500
1700
1450
1550
1650
1750
1800
Wind Break Height mm
Post C/L Spacing mm
MediumHighVery High
ExtraHigh Low
1400
1600
1500
1700
1450
1550
1650
1750
1800
500 1000 15000
MediumHighVery High
ExtraHigh Low
Post C/L Spacing mm
Note - Coach Screws into Timber mustbe bonded with Sika Supergrip 2hr
Note - Coach Screws into Timber mustbe bonded with Sika Supergrip 2hr
For 10mm Semi Frameless Glass
For 10mm Semi Frameless Glass
Group 1
Applies to Mountings
TOP Fix to Concrete - Baseplate JEC 200
TOP Fix to Concrete - Baseplate JEC 201
TOP Fix to Concrete - Embed Post in Concrete Slab
FACE Fix to Timber - Gutter Bracket - Coachscrews
FACE Fix to Timber - Gutter Bracket - Bolts
FACE Fix to Timber - Gutter Bracket - Water proofed Deck
FACE Fix to Steel - Gutter Bracket
FACE Fix to Concrete Slab - Gutter Bracket
FACE Fix Post to Steel
FACE Fix Post to Concrete Slab
Group 2
Applies to Mountings
TOP Fix to Timber - Baseplate JEC 200
TOP Fix to Timber - Baseplate JEC 221
TOP Fix to Steel (with timber deck)- Baseplate JEC 221
FACE Fix Post to Timber - Coachscrews
FACE Fix Post to Timber - Bolts
FACE Fix Post to Waterproofed Timber Deck
Wind Break Height mm
BA LU S T R A D E S YS T E M S
Page 48
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Baluster Design Guide for Building Types below. For other applications contact Juralco Aluminium
NZBC Requirements - Section F4 : Safety from falling
Post C/L = PCL
MOS
HandrailHeight above Deck(or Top of Glass)
= HH
MOS
MOS
HH = Minimum Height of Hand Rail or Top edge of Frameless Glass
Above Floor Level
Building Type Location
Detached dwellings andwithin household unitsof multi unit dwellings
Other Buildings andcommon areas ofmulti unit dwellings
Swimming Pools
Stairs, ramps and their landings
Balconies, decks and the edgesof internal floors and mezzanines
Stairs and ramps, excluding landings
Barriers within 530mm of the front of fixed seating
All other locations
MOS = Max Opening Size
PCL = Max Post centre line distancefor fastening onto timber
With Baluster Rails - Refer charts previous page
With 6mm toughened Glass infill Panels - Refer charts previous page
With 10mm toughened Glass infill Panels - Refer charts previous page
HH = 900mm
HH = 1000mm
HH = 900mm
HH = 800mm
HH = 1100mm
HH = 1200mm
Nominal 100mm, use 99mm
PCL = 1400mm
PCL = 1400mm
PCL = 1400mm
MOS = 99mm
Notes -
1 - Heights are measured vertically from finished floor level (ignoring carpet or vinyl, or similar thickness coverings)
on floors, landings and ramps. On stairs the height is measured vertically from the pitch line or stair nosing.
2 - A landing is a platform with the sole function of providing access.
3 - Household unit does not include a hostel, boarding house, motel or other specalised accommodation.
4 - Stairs or ramps for all other buildings does not include landings - use ‘All other locations’.
5 - The triangular opening formed by the riser, tread and bottom rail of a barrier on a stair shall be of such a size that a
150mm dia ball cannot pass through it. Except for swimming pools, where the diameter shall be 100mm.
6 - Barriers to swimming pools shall have in addition to performance F4,3-4
a - All gates and doors fitted with latching devices not readily operated by children, and constructed to automatically close and latch
when released from any stationary position 150mm or more from the closed and secured position.
Excluding sliding and sliding folding doors that give access to the immediate pool surround from a building that forms part of the barrier and,
b - No permanent objects on the outside or inside that could provide a climbing step.
7 - No toe holds between the heights of 150mm and 760mm above the floor level or stair nose.
Max dimensions
Min dimensions
PCL = Max Post centre line distancefor fastening onto steel or concrete
With Baluster Rails - Refer charts previous page
With 6mm toughened Glass infill Panels - Refer charts previous page
With 10mm toughened Glass infill Panels - Refer charts previous page
PCL = 1500mm
PCL = 1500mm
PCL = 1500mm
The PCL dimensions above are maximums only; in most circumstances PCL will be less than above - refer to charts on previous page
Juralco EDGE Balustrade System building code compliance documentation requires all balustrade installations are to be completed in accordance with the requirements of our authorised installer certification.
BA LU S T R A D E S YS T E M S
Page 49
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Front/Outside
Front/Outside
Front/Outside
Front/Outside
Handrail Attach
Post Caps - no swivel/clamp
All tap fit
Post Caps - with swivel/clamp Post Caps - with swivel/clamp - to Handrail
Showing 35deg max inclination - for all handrails
All handrails identical - clamp attach with M8 grubscrew
Baseplate to Post Attach
JVBHT SCREW/ 50 x 10 C/S PK SQ drive high tensile screws
Attach from top with special14g dia x 50mm SS PK Capscrew
General Connections
Use whenJEC14GWASHERattaching Post cap to Post top
Front/Outside
Use for 10mm Toughened Glass with Handrail, or 13.2mm Laminated Glass with no Handrail.Top Protection Cap recommended
Drill 2 x 4dia holes at 12mm C/L
Glass Support Attach
2 x No 8 x 16 SS PK Screws
Glass Support Bracket (Nylon)
10
12
Showing Glass and sealsabove the Glass Support Bracket
Showing Standard Infillbelow Glass Support Bracket
Glass Edge
Standard Infillbelow Glass Support Bracket
Use appropriate Plastic Packer
BA LU S T R A D E S YS T E M S
Page 50
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
General Connections
Handrail Attach at Corner Post
All handrails identical - clamp attach with M8 grubscrew
Handrail example - 100mm Aerofoil
Attach - M8 grubscrew
Top Cap - Corner Postand Hand Rail Mount
Handrail example 100mm Aerofoil
Attach - M8 grubscrew
Corner Post
Corner Plate
Corner Plate
Plan view above, looking down through1 - Hand rail2 - Top Cap/Handrail Corner Mount3 - Corner Post
Top Cap - Corner Postand Hand Rail Mount
Corner Post
BA LU S T R A D E S YS T E M S
Page 51
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Bottom Rail to Post Attach
Drill 2 x 4dia holes at 9mm C/L
9
8.5
Bottom face ofBottom Rail
Drill 2 x 4dia holes at 9mm C/L
25
Attaching Bottom/Top Railto Standard Post/Top Mount
Attaching Bottom/Top Railto Double Pocket Post/Top mount
Drill 1 x 4.5dia hole
Attaching Bottom/Top Railto Standard Post/Face Fix
Attaching Bottom/Top Railto Double Pocket Post/Face Fix
Drill Bottom/Top Rail
Cut Spigot 32mm long
Drill 1 x 6dia hole
10
Bottom/Top Rail
25
Bottom/Top Rail
25
25 10
Bottom/Top Rail
10
1015
15
General Connections
Screw from BottomFor Bottom Rail
Drill 2 x 4dia holes at 9mm C/Lon this face
No 8 x 12 C/S PK SQ drive screw
No 8 x 38 PK SQ drive screws
Drill hole4.5mm dia
Drill 2 x 4dia holes at 9mm C/L
9
8.5
Top face ofTop Rail
Screw from TopFor Top Rail
No 8 x 12 C/S PK SQ drive screw
No 8 x 38 PK SQ drive screws
Drill hole4.5mm dia
Drill Bottom/Top Rail
Bottom/Top Rail
Drill 1 x 6dia hole
Drill 1 x 6dia hole
Drill 1 x 6dia hole
Drill 1 x 4.5dia hole Drill 1 x 4.5dia hole
Drill 1 x 4.5dia hole
BA LU S T R A D E S YS T E M S
Page 52
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99
Handrail Height above Deck
= HH
Post C/L = PCL
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
5 - Cutting
Post C/L
Glass edge
4 - Glass, Width Offsets
Post
Bottom Rail
Front/Outside
7mm Glazingwedge
D Glazingwedge
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-2x22-99 = HH - 143
e - 6mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 16mm
12
22Glazingblock
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
Infill clip
Glass Bottom
22.5
Front/Outside
Selected Baseplate
Deck
99Max
Open Gap
3 - Height offsets
6mm Toughened Glass - Fully Framed. Handrail + Bottom Rail. Top Mount
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap/Handrail mount bracket
14.5
14.5
Post Cap Recess
Edge incl1.5mm packer
Cap + Handrail mount - Red outline
Post, Cap C/L
H/PP1.5mm Plastic Packer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 53
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Handrail Height above Deck
= HH
Post C/L = PCL
2
3
4
5 - Cutting
Post C/L
Glass edge
4 - Glass, Width Offsets
Post
Bottom Rail
Front/Outside
7mm Glazingwedge
D Glazingwedge
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-2x22-99 = HH - 143
e - 6mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 16mm (see above note)
22.5
3 - Height offsets
6mm Toughened Glass - Fully Framed. Handrail + Bottom Rail. Gutter Brkt Face Fix
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap/Handrail mount bracket
14.5
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
22Glazingblock
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
Glass Bottom
OL = Overlap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Deck 99mm max
D= Distance
G= Gap
Gutter Bracket JEC 137/65
See note below
D vertical
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 54
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail,Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-2x22-D = HH - 44 - D
e - 6mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 16mm (see above note)
22
5 - Cutting
Glazingblock
Bottom RailSpigot
2
3
4
7mm Glazingwedge
D Glazingwedge
PostBottom Cap
14.5
Glass edge
4 - Glass, Width Offsets
Bottom Rail
Front/Outside
7mm Glazingwedge
D Glazingwedge
Glass Bottom
Post C/L
22.5
Post
OL = OverlapDepending on
chosen Face fixing, about 200mm min
Handrail Height above Deck
= HH
See note below
D vertical
3mm Washer, Packers
3 - Height offsets
6mm Toughened Glass- Fully Framed. Handrail + Bottom Rail. Face Fix
Post Stiffener
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap/Handrail mount bracket
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 55
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL
5 - Cutting
Glass edge
4 - Glass, Width Offsets
Bottom Rail
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-2x22-99 = HH - 143
e - 6mm Glass width
= PCL-2x22.5-2x50 = PCL - 145
12
22Glazing
block
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
22.5
Standard Infill clip
50 gap
Glass Bottom
Post C/L
2
3
4
Selected Baseplate
Deck
Handrail Height above Deck
= HH
50 gap
3 - Height offsets
6mm Toughened Glass - Full Height. Handrail + Bottom Rail. Top Mount
99Max
Open Gap
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
BA LU S T R A D E S YS T E M S
Page 56
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
Glass edge
4 - Glass, Width Offsets
Bottom Rail
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-2x22-D = HH - 44 - D
e - 6mm Glass width
= PCL-2x22.5-2x50 = PCL - 145
22.5
Standard Infill clip
50 gap
Post C/L
2
3
4 Handrail Height above Deck
= HH
50 gap
6mm Toughened Glass- Full Height. Handrail + Bottom Rail. Gutter Brkt Face Fix
3 - Height offsets
22Glazingblock
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
Glass Bottom
OL = Overlap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Deck 99mm max
D= Distance
G= Gap
See note below
D vertical
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
BA LU S T R A D E S YS T E M S
Page 57
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
Post C/L
50 gap
Glass edge
4 - Glass, Width Offsets
Post
Bottom Rail
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-2x22-D = HH - 44 - D
e - 6mm Glass width
= PCL-2x22.5-2x50 = PCL - 145
22.5
Standard Infill clip
50 gap
Post stiffener
Face Fix Infill clip
2
3
4
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Handrail Height above Deck
= HH
See note below
D vertical
3 - Height offsets
6mm Toughened Glass - Full Height. Handrail + Bottom Rail. Face Fix
22Glazingblock
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
PostBottom Cap
Glass Bottom
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
BA LU S T R A D E S YS T E M S
Page 58
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
Post C/L
Glass edge
4 - Glass, Width Offsets
Post
Bottom Rail
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail (x2), Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-27-22-2x99-48 = HH - 295
e - 6mm Glass width
= PCL-2x22.5-2x50 = PCL - 145
12
22Glazingblock
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
Standard Infill clip
50 gap
99Open Gap
Glass Top
48
27
Glass Bottom
2
3
4
Selected Hand Rail
Selected Baseplate
Deck
22.5
Hand RailBase
Handrail Height above Deck
= HH
99 gap
99 gap
50 gap
3 - Height offsets
6mm Toughened Glass - Full Height. Handrail + Split Rails. Top Mount
99Max
Open Gap
This dimensionto ensure glass insertsinto pre assembledTop/Bottom Rails
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
73
Handrail Top
Post Top
Post Top
BA LU S T R A D E S YS T E M S
Page 59
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
Post C/L
Glass edge
4 - Glass, Width Offsets
Post
Bottom Rail
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail (x2), Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-48-27-22-99-D = HH - 196 - D
e - 6mm Glass width
= PCL-2x22.5-2x50 = PCL - 145
Standard Infill clip
50 gap
2
3
4
22.5
Handrail Height above Deck
= HH
99 gap
50 gap
3 - Height offsets
6mm Toughened Glass - Full Height. Handrail + Split Rails. Gutter Brkt Face Fix
99Open Gap
Glass Top
48
27
Selected Hand Rail
Hand RailBase
22
D Glazingwedge
Glass Bottom
OL = Overlap
Note - Because the Bottom Rail is mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
D= Distance
Glazingblock
Bottom RailSpigot
7mm Glazingwedge
99mm max
G= Gap
See note below
D vertical
Deck
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
This dimensionto ensure glass inserts
into pre assembledTop/Bottom Rails
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
73
Handrail Top
Post Top
Post Top
BA LU S T R A D E S YS T E M S
Page 60
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
Post C/L
Glass edge
4 - Glass, Width Offsets
Post
Bottom Rail
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail (x2), Cut to
= PCL-2x22.5 = PCL - 45
d - 6mm Glass height
= HH-48-27-22-99-D = HH - 196 - D
e - 6mm Glass width
= PCL-2x22.5-2x50 = PCL - 145
22.5
Standard Infill clip
50 gap
Post stiffener
2
3
4 Handrail Height above Deck
= HH
99 gap
50 gap
See note below
D vertical
3 - Height offsets
6mm Toughened Glass - Full Height. Handrail + Split Rails. Face Fix
48
27
Selected Hand Rail
Hand RailBase
99Open Gap
22Glazingblock
Bottom RailSpigot
7mm Glazingwedge
D Glazingwedge
PostBottom Cap
Glass Bottom
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Note - Because the Bottom Rail is mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
Glass Top
This dimensionto ensure glass inserts
into pre assembledTop/Bottom Rails
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
73
Handrail Top
Post Top
Post Top
BA LU S T R A D E S YS T E M S
Page 61
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL
5 - Cutting
14.5
Glass edge
4 - Glass, Width Offsets
Bottom Rail
Front/Outside
5mm Glazingwedge
D Glazingwedge
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - 8mm Glass height
= HH-22-99 = HH - 121
d - 8mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 16mm (see above note)
12
Infill clip
Glass Bottom
Post C/L
22.5
Post
Glass SupportBracket
2
3
4
Selected Baseplate
Deck
Handrail Height above Deck
= HH
3 - Height offsets
8mm Toughened Glass - Semi Frameless. Handrail. Top Mount
99Max
Open Gap
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap/Handrail mount bracket
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 62
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
14.5
Glass edge
4 - Glass, Width Offsets
Bottom Rail
Front/Outside
5mm Glazingwedge
D Glazingwedge
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - 8mm Glass height
= HH-22-D
d - 8mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 16mm (see above note)
Post C/L
22.5
Post
2
3
4 Handrail Height above Deck
= HH
3 - Height offsets
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap/Handrail mount bracket
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
7mm Glazingwedge
D Glazingwedge
Glass Bottom
OL = Overlap
Note - Because the Bottom Glass Edgeis mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
.
Deck 99mm max
D= Distance
G= Gap
See note below
D vertical
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
8mm Toughened Glass - Semi Frameless. Handrail. Gutter Bracket Mount
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 63
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - 8mm Glass height
= HH-22-D
d - 8mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 16mm (see above note)
14.5
Glass edge
4 - Glass, Width Offsets
Front/Outside
D Glazingwedge
Post C/L
22.5
Post
Glass SupportBracket
5mm Glazingwedge
Infill clip
2
3
4 Handrail Height above Deck
= HH
See note below
.
D vertical
3 - Height offsets
8mm Toughened Glass - Semi Frameless. Handrail. Face Fix
Post Stiffener
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap/Handrail mount bracket
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
PostBottom Cap
Glass Bottom
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Glass Edgeis mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
7mm Glazingwedge
D Glazingwedge
73
Glass Top
Handrail Top
22
Post Top
Post Top
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 64
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
5 - Cutting
14.5
Glass edge
4 - Glass, Width Offsets
Front/Outside
3mm Glazingwedge
D Glazingwedge
a - Hand Rail = Use maximum lengths
b - Post, Cut to
=HH-54-12
c - 10mm Glass height
= HH - 104
d - 10mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 29mm (see above note)
Post C/L
22.5
Post
99 gap
Post C/L = PCL
3 - Height offsets
10mm Toughened Glass - Semi Frameless. Top Mount. Handrail
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap bracket
12
Infill clip
Glass Bottom
Glass SupportBracket
Selected Baseplate
Deck
99Max
Open Gap
Handrail Height above Deck
= HH
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
3mm Glazingwedge D seal
73
Glass Top
Handrail Top
22
Post Top
Post Top
Handrail Top
54
5 Glass Top29
A Corner Post is available for 10mm Glass, Inline - Semi Frameless. Top Mount only
with 110mm sq JEC 222 Baseplate
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 65
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
5 - Cutting
4 - Glass, Width Offsets
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-54+ OL
c - 10mm Glass height
= HH-5-D
d - 10mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 29mm (see above note)
Post C/L = PCL
3 - Height offsets
10mm Toughened Glass - Semi Frameless. Gutter Brkt Face Fix. Handrail
7mm Glazingwedge
D Glazingwedge
Glass Bottom
OL = Overlap
Note - Because the Bottom Glass Edgeis mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
.
Deck 99mm max
D= Distance
G= Gap
See note below
D vertical
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Handrail Height above Deck
= HH
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
73
Glass Top
Handrail Top
22
Post Top
Post Top
Handrail Top
54
5 Glass Top29
3mm Glazingwedge D seal
14.5
Glass edge
Front/Outside
3mm Glazingwedge
D Glazingwedge
Post C/L
22.5
Post
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap bracket
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 66
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
5 - Cutting
4 - Glass, Width Offsets
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-54+OL
c - 10mm Glass height
= HH-5-D
d - 10mm Glass width
= PCL-2x14.5 = PCL - 29
or tight distance between posts
at deck level + 29mm (see above note)
See note below
D vertical
3 - Height offsets
10mm Toughened Glass - Semi Frameless. Face Fix. Handrail
Glass SupportBracket
Infill clip
.
PostBottom Cap
Glass Bottom
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Glass Edgeis mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Handrail Height above Deck
= HH
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Glass Top
Handrail Top
22
73
Glass Top
Handrail Top
22
Post Top
Post Top
Handrail Top
54
5 Glass Top29
3mm Glazingwedge D seal
14.5
Glass edge
Front/Outside
3mm Glazingwedge
D Glazingwedge
Post C/L
22.5
Post
Note: Glass Edge 14.5mm from Post C/Lbecause of Post Cap bracket
14.5
Post Cap Recess
Edge incl1.5mm packer
Post, CapC/L
H/PP1.5mm Plastic Packer
Cap + Handrail mount - Red outline
Legs for Handrail Clamp
BA LU S T R A D E S YS T E M S
Page 67
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
5 - Cutting
10
Glass edge
4 - Glass, Width Offsets
Front/Outside
3mm Glazingwedge
D Glazingwedge
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= 840 min
c - 10mm Glass height
= GH - 99
d - 10mm Glass width
= PCL-2x10 = PCL - 20
or tight distance between posts
at deck level + 20mm
Post C/L
22.5
Post
2 -Glass Top - Offsets
99 gap
Post C/L = PCL
3 - Height offsets
10mm Toughened Glass - Semi Frameless. Top Mount. Handrail + JEC 29 Bracket mounted on Post
A Corner Post is not suitable available forthis configuration
Post, CapC/L
Cap - Red outline
Post
H/PP1.5mm Plastic Packer
Note: Glass Edge 10mm from Post C/L
12
Infill clip
Glass Bottom
Glass SupportBracket
Selected Baseplate
Deck
99Max
Open Gap
Glass Height above Deck
=GH
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
2
3
4
Othersuitable
Handrails
Front/Outside
50
61
Balustrade height above Deck
Post Height = Balustrade height
above Deck-121mm
Note: For the threeHandrails aboveadd 20mm to theBalustrade height above the Barrier height.ie should be 70mm,not 50mm
Required Barrier Heightabove Deck, 1000mm
JEC 29 Hand Rail Brktand JEB/222
Interlinking Rail
BA LU S T R A D E S YS T E M S
Page 68
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
5 - Cutting
Post C/L = PCL
3 - Height offsets
10mm Toughened Glass - Semi Frameless. Gutter Brkt Face Fix. Handrail+ JEC 29 Bracket mounted on Post
7mm Glazingwedge
D Glazingwedge
Glass Bottom
OL = Overlap
.
Deck 99mm max
D= Distance
G= Gap
See note below
D vertical
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Glass Height above Deck
= GH
2
3
4
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= 850 + OL
c - 10mm Glass height
= GH-D
d - 10mm Glass width
= PCL-2x10 = PCL - 20
or tight distance between posts
at deck level + 20mm
10
Glass edge
4 - Glass, Width Offsets
Front/Outside
3mm Glazingwedge
D Glazingwedge
Post C/L
22.5
Post
Post, CapC/L
Cap - Red outline
Post
H/PP1.5mm Plastic Packer
Note: Glass Edge 10mm from Post C/L
Note - Because the Bottom Glass Edge is mountedforward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
2 -Glass Top - Offsets
Othersuitable
Handrails
Front/Outside
50
61
Balustrade height above Deck
Post Height = Balustrade height
above Deck-121mm
Note: For the threeHandrails aboveadd 20mm to theBalustrade height above the Barrier height.ie should be 70mm,not 50mm
Required Barrier Heightabove Deck, 1000mm
JEC 29 Hand Rail Brktand JEB/222
Interlinking Rail
BA LU S T R A D E S YS T E M S
Page 69
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Post C/L = PCL
5 - Cutting
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= 850 + OL
c - 10mm Glass height
= GH-D
d - 10mm Glass width
= PCL-2x10 = PCL - 20
or tight distance between posts
at deck level + 20mm
See note below
D vertical
3 - Height offsets
10mm Toughened Glass - Semi Frameless. Face Fix. Handrail + JEC 29 Bracket mounted on Post
Glass SupportBracket
Infill clip
.
PostBottom Cap
Glass Bottom
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Glass Edge is mountedforward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Glass Height above Deck
= GH
2
3
4
®Juralco EDGE Balustrade Systems - Design Details
10
Glass edge
4 - Glass, Width Offsets
Front/Outside
3mm Glazingwedge
D Glazingwedge
Post C/L
22.5
Post
Post, CapC/L
Cap - Red outline
Post
H/PP1.5mm Plastic Packer
Note: Glass Edge 10mm from Post C/L
2 -Glass Top - Offsets
Othersuitable
Handrails
Front/Outside
50
61
Balustrade height above Deck
Post Height = Balustrade height
above Deck-121mm
Note: For the threeHandrails aboveadd 20mm to theBalustrade height above the Barrier height.ie should be 70mm,not 50mm
Required Barrier Heightabove Deck, 1000mm
JEC 29 Hand Rail Brktand JEB/222
Interlinking Rail
BA LU S T R A D E S YS T E M S
Page 70
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
5 - Cutting
4 - Glass, Width Offsets
a - Post, Cut to
= GEH -12
b - 13.2mm Glass height
= GEH- 99
c - 13.2mm Glass width
= PCL-2x10 = PCL - 20
or tight distance between posts
at deck level + 20mm
2 -Glass Top - Offsets1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
99 gap
Glass EdgeHeight above Deck
= GEH
Post C/L = PCL
2
3
4
Post C/L
Glass Flush to top of Post
13.2mm Laminated Toughened Glass - Semi Frameless. Top Mount
Post, CapC/L
Cap - Red outline
Post Glass Edge
10
12
Infill clip
Glass Bottom
Glass SupportBracket
Selected Baseplate
Deck
99Max
Open Gap
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
JET B Seal
3 - Height offsets
JET B Seal
13.2mm LaminatedToughened Glass
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
JEC 20 Cap
A Corner Post is available Inline - Semi Frameless. Top Mount onlywith 110mm sq JEC 222 Baseplate (TBA)
Top Protection Cap JET 212 between Posts highly recommended
BA LU S T R A D E S YS T E M S
Page 71
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
5 - Cutting
4 - Glass, Width Offsets
a - Post, Cut to
= GEH+ OL
b - 13.2mm Glass height
= GEH-D
c - 13.2mm Glass width
= PCL-2x10 = PCL - 20
or tight distance between posts
at deck level + 20mm
2 -Glass Top - Offsets
Glass EdgeHeight above Deck
= GEH
Post C/L = PCL
2
3
4
3 - Height offsets
OL = Overlap
Note - Because the Bottom Glass Edgeis mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
.
Deck 99mm max
D= Distance
G= Gap
See note below
D vertical
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
13.2mm Laminated Toughened Glass - Semi Frameless. Gutter Brkt Mount
Post C/L
Glass Flush to top of Post
Glass Bottom
Glass SupportBracket
JET B Seal
Post, CapC/L
Cap - Red outline
Post Glass Edge
10
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
JET B Seal
13.2mm LaminatedToughened Glass
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
JEC 20 Cap
Top Protection Cap JET 212 between Posts highly recommended
BA LU S T R A D E S YS T E M S
Page 72
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Glass edgeHeight above Deck
= GEH
Post C/L = PCL
5 - Cutting
4 - Glass, Width Offsets
2 - Glass Top - Offsets
2
3
4
a - Post, Cut to
= GEH + OL
b - 13.2mm Glass height
= GEH-D
c - 13.2mm Glass width
= PCL-2x10 = PCL - 20
or tight distance between posts
at deck level + 20mm
See note below
D vertical
3 - Height offsets
Glass SupportBracket
Infill clip
.
PostBottom Cap
Glass Bottom
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Glass Edgeis mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 91mmG Gap = 20mm, D = 86mmG Gap = 30mm, D = 80mmG Gap = 40mm, D = 72mmG Gap = 50mm, D = 61mm
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Top Protection Cap JET 212 between Posts highly recommended
13.2mm Laminated Toughened Glass - Semi Frameless. Face Fix
Post C/L
Glass Flush to top of Post
JET B Seal
Post, CapC/L
Cap - Red outline
Post Glass Edge
10
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
JET B Seal
13.2mm LaminatedToughened Glass
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
JEC 20 Cap
BA LU S T R A D E S YS T E M S
Page 73
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL
5 - Cutting
Post C/L
4 - Width Offsets
PostBottom Rail
Front/Outside
17mm sq Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 17mm sq Baluster, Cut to
= HH-34.5-31.5-99 = HH - 165
22.5
Handrail Height above Deck
= HH
3 - Height offsets
17mm Baluster - Full Height. Handrail + Bottom Rail. Top Mount
12
Selected Baseplate
Deck
99Max
Open Gap
31.5
Bottom RailSpigot
Baluster Bottom
Rebate Infill clip
17mm sq Baluster
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Baluster Top
Handrail Top
34.5
73
Handrail Top
Post Top
Post Top
Rebate Infill clip
Baluster Top
34.5
17mm sq Baluster
HandrailBase
48
BA LU S T R A D E S YS T E M S
Page 74
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
31.5
Bottom RailSpigot Baluster Bottom
Front/Outside
Rebate Infill clip
17mm sq Baluster
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Baluster Top
Handrail Top
34.5
73
Handrail Top
Post Top
Post Top
5 - Cutting
Post C/L
4 - Width Offsets
PostBottom Rail
Front/Outside
Rebate Infill clip
17mm sq Baluster
Baluster Top
34.5
17mm sq Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)Handrail
Base
48
2
3
4
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 17mm sq Baluster, Cut to
= HH-34.5-31.5-D = HH - 66 - D
22.5
Handrail Height above Deck
= HH
3 - Height offsets
17mm Baluster - Full Height. Handrail + Bottom Rail. Gutter Brkt Face Fix
OL = Overlap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
.
Deck 99mm max
D= Distance
G= Gap
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 75
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Baluster Top
Handrail Top
34.5
73
Handrail Top
Post Top
Post Top
5 - Cutting
Post C/L
4 - Width Offsets
PostBottom Rail
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 17mm sq Baluster, Cut to
= HH-34.5-31.5-D = HH - 66 - D
22.5
Front/Outside
Rebate Infill clip
17mm sq Baluster
Baluster Top
34.5
17mm sq Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
HandrailBase
48
2
3
4Handrail Height
above Deck= HH
See note below
D vertical
3 - Height offsets
17mm Baluster - Full Height. Handrail + Bottom Rail. Face Fix
Post Stiffener
PostBottom Cap
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
31.5
Bottom RailSpigot Baluster Bottom
Rebate Infill clip
17mm sq Baluster
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 76
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL 17mm sq Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
Post C/L
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
Handrail Top
Post Top
Post Top
Standard infill clip
48
48
Front/Outside
5 - Cutting
Post C/L
4 - Width Offsets
Post
Bottom Rail+ Rebate InfillClip
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 17mm sq Baluster, Cut to
= HH-48-99x2-31.5x2 = HH - 309
22.5
First Baluster
Handrail Height above Deck
= HH
17mm Baluster - Split Rail. Handrail + Top and Bottom Rail. Top Mount
12
31.5
Bottom RailSpigot
99Open Gap
48
Front/Outside
Selected Hand Rail
Selected Baseplate
Deck
Hand RailBase
3 - Height offsets
99Max
Open Gap
Baluster Bottom
Baluster Top
31.5
73
Rebate Infill clip
17mm sq Baluster
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 77
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
3 - Height offsets
99 gap
Post C/L = PCL 17mm sq Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
Post C/L
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
Handrail Top
Post Top
Post Top
Standard infill clip
48
48
Front/Outside
5 - Cutting
Post C/L
4 - Width Offsets
Post
Bottom Rail+ Rebate InfillClip
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 17mm sq Baluster, Cut to
= HH-48-99-31.5x2-D = HH - 210 -D
22.5
First Baluster
Handrail Height above Deck
= HH
17mm Baluster - Split Rail. Handrail + Top and Bottom Rail. Gutter Brkt Face Fix
99Open Gap
48
31.5
Selected Hand Rail
Hand RailBase
31.5
OL = Overlap
Note - Because the Bottom Rail is mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
D= Distance
Bottom RailSpigot
99mm max
G= Gap
Rebate Infill clip
17mm sq Baluster
Baluster Top
Baluster Bottom
73
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 78
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL 17mm sq Baluster
2
3
4
Post C/L
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
Handrail Top
Post Top
Post Top
Standard infill clip
48
48
Front/Outside
5 - Cutting
Post C/L
4 - Width Offsets
Post
Bottom Rail+ Rebate InfillClip
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 17mm sq Baluster, Cut to
= HH-48-99-31.5x2 - D = HH - 210 - D
22.5
First Baluster
Handrail Height above Deck
= HH
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
D vertical
17mm Baluster - Split Rail. Handrail + Top and Bottom Rail. Face Fix
Post Stiffener
3 - Height offsets
Baluster Top
48
Selected Hand Rail
Hand RailBase
99Open Gap
Bottom RailSpigot
PostBottom Cap
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Note - Because the Bottom Rail is mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
31.5
Baluster Bottom
73
Rebate Infill clip
17mm sq Baluster
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 79
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL
60mm Slat Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Baluster Top
Handrail Top
34.5
73
Handrail Top
Post Top
Post Top
Rebate Infill clip
Baluster Top
34.5
60mm Slat Baluster
HandrailBase
48
5 - Cutting
Post C/L
4 - Width Offsets
Post
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 60mm Slat Baluster, Cut to
= HH-34.5-31.5-99 = HH - 165
22.5
Front/Outside
Bottom Rail+ Rebate InfillClip
First Baluster
Handrail Height above Deck
= HH
3 - Height offsets
60mm Slat - Full Height. Handrail + Bottom Rail. Top Mount
12
Selected Baseplate
Deck
99Max
Open Gap
31.5
Bottom RailSpigot
Baluster Bottom
Rebate Infill clip
60mm Baluster
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 80
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL 60mm Slat Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Baluster Top
Handrail Top
34.5
73
Handrail Top
Post Top
Post Top
Rebate Infill clip
Baluster Top
34.5
60mm Slat Baluster
HandrailBase
48
5 - Cutting
Post C/L
4 - Width Offsets
Post
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 60mm Slat Baluster, Cut to
= HH-34.5-31.5-D-OL= = HH-66-D-OL
22.5
Front/Outside
Bottom Rail+ Rebate InfillClip
First Baluster
Handrail Height above Deck
= HH
60mm Slat - Full Height. Handrail + Bottom Rail. Gutter Brkt Face Fix
3 - Height offsets
31.5
Bottom RailSpigot Baluster Bottom
Rebate Infill clip
OL = Overlap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
.
Deck 99mm max
D= Distance
G= Gap
60mm Slat Baluster
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 81
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL 60mm Slat Baluster
2
3
4
Post C/L
Front/Outside
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Baluster Top
Handrail Top
34.5
73
Handrail Top
Post Top
Post Top
Rebate Infill clip
Baluster Top
34.5
60mm Slat Baluster
HandrailBase
48
5 - Cutting
Post C/L
4 - Width Offsets
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 60mm Slat Baluster, Cut to
= HH-34.5-31.5-D = HH - 66 - D
22.5
Front/OutsidePost
Bottom Rail+ Rebate InfillClip
First Baluster
Handrail Height above Deck
= HH
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
See note below
D vertical
3 - Height offsets
60mm Slat - Full Height. Handrail + Bottom Rail. Face Fix
Post Stiffener
PostBottom Cap
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
Note - Because the Bottom Rail is mounted forward of the Deck Edge, the
D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
31.5
Bottom RailSpigot Baluster Bottom
Rebate Infill clip
60mm Slat Baluster
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 82
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
99 gap
Post C/L = PCL 60mm Slat Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
5 - Cutting
Post C/L
4 - Width Offsets
Post
Bottom Rail+ Rebate InfillClip
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73-12 = HH - 85
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - , Cut to60mm Slat Baluster
= HH-48-99x2-31.5x2 = HH - 309
22.5
First Baluster
Post C/L
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
73
Handrail Top
Post Top
Post Top
Standard infill clip
48
48
Front/OutsideHandrail Height
above Deck= HH
60mm Slat - Split Rail. Handrail + Top and Bottom Rail. Top Mount
12
31.5
Bottom RailSpigot
99Open Gap
48
Selected Hand Rail
Selected Baseplate
Deck
Hand RailBase
3 - Height offsets
99Max
Open Gap
Baluster Bottom
Baluster Top
31.5
60mm Slat Baluster
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 83
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL 60mm Slat Baluster
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
2
3
4
5 - Cutting
Post C/L
4 - Width Offsets
Post
Bottom Rail+ Rebate InfillClip
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - , Cut to60mm Slat Baluster
= HH-48-99-31.5x2-D = HH - 210 - D
22.5
First Baluster
Post C/L
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
73
Handrail Top
Post Top
Post Top
Standard infill clip
48
48
Front/Outside
Handrail Height above Deck
= HH
60mm Slat - Split Rail. Handrail + Top and Bottom Rail. Gutter Brkt Face Fix
3 - Height offsets
99Open Gap
48
31.5
Selected Hand Rail
Hand RailBase
31.5
OL = Overlap
Note - Because the Bottom Rail is mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
D= Distance
Bottom RailSpigot
99mm max
G= Gap
Rebate Infill clip
Baluster Top
Baluster Bottom
60mm Slat Baluster
See note below
D vertical
Gutter Bracket JEC 137/65
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 84
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Design Details
Post C/L = PCL
2
3
4
Post C/L
73
70
Post C/L
Post C/L Post C/L
32
26 29
2 - Handrail - Offsets
Handrail Top
73
Handrail Top
Post Top
Post Top
Standard infill clip
48
48
Front/Outside
5 - Cutting
Post C/L
4 - Width Offsets
Post
Bottom Rail+ Rebate InfillClip
Front/Outside
a - Hand Rail = Use maximum lengths
b - Post, Cut to
= HH-73+OL
c - Bottom Rail, Cut to
= PCL-2x22.5 = PCL - 45
d - 60mm Slat Baluster, Cut to
= HH-48-99-31.5x2- D = HH - 210 - D
22.5
First Baluster
60mm Slat Baluster
Handrail Height above Deck
= HH
See note below
Baluster End Gap = BEG (max 99mm)
Baluster Gap = BG (normally 99mm)
D vertical
Post Stiffener
3 - Height offsets
Baluster Top
48
Selected Hand Rail
Hand RailBase
99Open Gap
Bottom RailSpigot
PostBottom Cap
OL = OverlapDepending on
chosen Face fixing, about 200mm min
99mm maxDeck
D= Distance
G= Gap
D max values for a 99mm Opening to the deck
G Gap = 10mm, D = 96mmG Gap = 20mm, D = 92mmG Gap = 30mm, D = 88mmG Gap = 40mm, D = 82mmG Gap = 50mm, D = 75mm
Note - Because the Bottom Rail is mounted
forward of the Deck Edge, the D Dimension is no longer 99mm.
31.5
Baluster Bottom
60mm Slat Baluster
60mm Slat - Split Rail. Handrail + Top and Bottom Rail. Face Fix
Optional Spacers JVB 12510mm or 30mm plus JVB 126 EPDM washer
1 - Taking into account Wind zone, Balustrade Height and Post Mounting type, choose Post spacing C/L
BA LU S T R A D E S YS T E M S
Page 85
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Suggested Corner Design Details
These Set out constraints apply to all 17mm sq and 60mm Slat Balusters
Bottom Rail
215 C/L
99 99
255 C/L
99 99
211
95 95
251
17mm sq Balusters - 215mm C/L max 60mm Slat Balusters - 255mm C/L max
Top Mount Postshown
Top Mount Postshown
17mm sq Baluster
Hand Rail
Bottom Rail
60mm Slat Baluster
Hand Rail
17mm Baluster - Full Height. Handrail + Bottom Rail. Top Mount, Gutter Brkt Face Fix or Face Fix
17mm Baluster - Split Rail. Handrail + Top and Bottom Rail. Top Mount, Gutter Brkt Face Fix or Face Fix
60mm Slat - Full Height. Handrail + Bottom Rail. Top Mount, Gutter Brkt Face Fix or Face Fix
60mm Slat - Split Rail. Handrail + Top and Bottom Rail. Top Mount, Gutter Brkt Face Fix or Face Fix
Face FixTop Mount Gutter Brkt Face Fix
Face FixTop Mount Gutter Brkt Face Fix
Face FixTop Mount Gutter Brkt Face Fix
Face FixTop Mount Gutter Brkt Face Fix
BA LU S T R A D E S YS T E M S
Page 86
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Suggested Corner Design Details
Post
10mm Glass, Inline - Semi Frameless. Hand Rail(Corner Post available for Top Mount)
150max recommended
Apply bead of RTV silicon the the inside face of Post Pocket for full height of glass panel
RTV fill
Top Mount Gutter Brkt Face Fix
Face Fix
Post
10mm Glass, Inline - Semi Frameless. Hand Rail + JEC 29 Bracket (Corner Post not applicable to Top Mount, this configuration)
150max recommended
Apply bead of RTV silicon the the inside face of Post Pocket for full height of glass panel
RTV fill
Top Mount Gutter Brkt Face Fix
Face Fix
Glass butt join + RTV Joint
Glass butt join + RTV Joint
JEC 29 Bracket
Handrail
Handrail
Post
13.2mm Laminated Glass, Inline - Semi Frameless.
150max recommended
Top Mount Gutter Brkt Face Fix
Face Fix
Glass butt join + RTV Joint
Top Protection Cap, between Posts recommended
JET B Seal
JEC W8 Wedgeand V60 Structural SealantFull height of pocket
10mm Glass, Inline - Semi Frameless. Corner Post - Handrail or Interlinking Rail Top Mount only
Top Mount
A Corner Post is available for 10mm Glass, Inline - Semi Frameless. Top Mount only
with 110mm sq JEC222 Baseplate
Handrail
(Corner Post to be available for Top Mount. TBA)
BA LU S T R A D E S YS T E M S
Page 87
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Floating Deck Edge
Slats JGF/2227
123mm x 17mm
Floating Deck
Face FixedEDGE posts
Face FixedGutter Brackets
Slats JGF/2227
123mm x 17mmCustom Corner,
Screwed
Custom Corner
Slats JGF/2227
123mm x 17mmMiter corner
Rebatted Infill ClipJEB 218
Screwed to Slats Miter corner,Screwed
All pages © Copyright Juralco Aluminium Building Products Ltd, 2017
FACE FIX EDGE POSTSEMIFRAMELESS Part No JEB/214/5
INFILL60mm SLAT
Part No JVB/019/5.3
INFILL123mm SLATPart No 2227
Rebated Infill ClipJEB 218Screwed to Slats
Infill Slat
Miter corner,Screwed
Infill Slat
Glass Edge
Standard Infillbelow Glass Support Bracket
Use appropriate Plastic Packer
End Cap
Infill 60mm Slatshown.
Or 123mm slat
Infill 60mm Slatshown.
Or 123mm slat
Rebatted Infill ClipJEB 218 Screwed to Slats
Basic Floating EDGE Cover LayoutBasic Floating EDGE Cover Layout + Glass Panel Above
BA LU S T R A D E S YS T E M S
Page 88
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
®Juralco EDGE Balustrade Systems - Glass Care and Maintenance
Glass Cleaning and Maintenance
Architectural glass products must be properly cleaned during the construction period so visual and aesthetic clarity are maintained. Because glass can
be permanently damaged if improperly cleaned, glass producers and fabricators recommend strict compliance with the following procedures.
First, determine whether the glass is clear, tinted or reflective. Surface damage is more noticeable on reflective glass compared with the other glass
products. If the reflective coated surface is exposed, either on the exterior or interior, special care must be taken when cleaning, as scratches can
result in coating removal and a visible change in light transmittance. Cleaning tinted and reflective glass in direct sunlight should be avoided. Cleaning
should begin at the top of the building and continue to the lower levels.
Commence cleaning by soaking the glass surfaces with clean water and a soap solution to loosen dirt or debris. Then, using a mild, non-abrasive
commercial window washing solution, uniformly apply the solution to the glass surfaces with a non-abrasive applicator and follow with a squeegee to
remove all of the cleaning solution from the glass surface.
Ensure that no metal parts of the cleaning equipment touch the glass surface and that no abrasive particles are trapped between the glass and the
cleaning materials. All water and cleaning solution residue should be dried from the window gaskets, sealants and frames.
Scratches and Metal Scrapers
Scratches can occur from hard pointed objects or poor handling, but most often occurs from the careless removal of foreign matter from the glass
surface.
Mortar splatter and paint are common offenders and efforts to remove after hardening almost always lead to surface damage. It is essential that the
foreign materials are removed before they harden. Better still, if construction work continues after glazing, that the glazed areas are protected by
adhesive plastic films or suitable tarpaulins or covers.
One of the common mistakes made by non-glass trades people, including glass cleaning contractors, is the use of razor blades or other metal
scrapers on a large portion of the glass surface. Using large blades to scrape a window clean carries considerable risk of causing damage to the
glass.
The glass industry, fabricators, distributors and installers neither condones nor recommends any scraping of glass surfaces with metal blades or
knives. Such scraping usually permanently damages or scratches the glass surfaces. When paint or other construction materials cannot be removed
with normal cleaning procedures, a new 25mm razor blade may have to be used. The razor blade should be used on small spots only. Cleaning should
be done in one direction only. Never scrape in a back and forth motion as this could trap particles under the blade that could scratch the glass.
Blades or scrapers can dislodge “pickup” on toughened glass. There are fine particles of glass that are fused on to the surface during toughening.
Once dislodged they can scratch the glass.
Glass Cleaning, Do’s and Don’ts
DO NOT..
- Do Not - Use Scrapers of any type or size on a Glass surface
- Do Not - Leave building dirt or residues to remain on Glass for a period of time.
- Do Not - Begin cleaning glass until you have identified the surface type.
- Do Not - Clean Glass surfaces in direct sunlight.
- Do Not - Allow dirty water or cleaning residues to remain on the Glass.
- Do Not - Begin cleaning before rinsing off a loose residues.
- Do Not - Use abrasive cleaning solutions, materials or solvents.
- Do Not - Allow metal parts of the cleaning equipment to come in contact with the Glass.
- Do Not - Trap abrasive particles between the cleaning material and the Glass.
DO...
- Clean glass promptly when dirt or building residues appear.
- Determine glass surface type.
- Exercise special care when cleaning coated surfaces.
- Avoid cleaning glass surfaces in direct sunlight.
- Start cleaning at the top of a building, then continue to lower levels.
- Soak the glass surface in a clean soapy solution before cleaning.
- Use a mild non abrasive commercial cleaner.
- Use a squeege to remove all cleaning solution.
- Try your procedures on a small window and check.
- Caution other trades re the care and protection of the glass surfaces.
Residues of surface grit may be present from the toughening production process.These grit particles must not be dragged across the surface.
NEVER use Metal Scrapers
All above reprinted with permission from Metro Glass Tech
BA LU S T R A D E S YS T E M S
Page 89
Issue 11/17
www.juralco.co.nz ph (09) 478 8018
®Juralco EDGE Balustrade Systems
BA LU S T R A D E S YS T E M S
Warning re use of solvents:
- In some cases strong solvents are recommended for thinning various types of paints and also for cleaning up mastics and sealants.
- These can be harmful to the extended life of the powder coated surface, and must not be used for cleaning purposes.
- It is important to note that the damage will not be visible immediately and may take up to l2 months to develop.
If paint splashes or sealants and mastics need to be removed then the following may be safely used:
Methylated Spirits, Ethyl Alcohol, lsopropanol or preferably a mild detergent in warm water.
Joinery Protection during Installation:
All the activity on a construction site means that your powder coated items
may get knocked or scratched, splattered with mortar,
plaster, textured coating or paint during the later stages of construction.
Please ensure that all powder coated articles are masked or covered at this time.
It is far easier to prevent accidents than to try and correct them.
Should your joinery receive mortar or paint splashes see that these are removed
before cure and follow the instructions contained in this brochure.
“IMPORTANT ALL TRADES”
This valuable aluminium joinery will suffer
permanent damage from: plaster, mortar
and paint splashes - Protect if splashes
occur - Immediately wash down joinery
with water or meths - Do not allow
splashes to harden! ~ Do not use solvents!
- Do not remove this label until final clean
completed.
This photograph display damage that has occurred on site, post
installation. The photo of the masked joinery displays clear signs
of damage that could have occurred were it not masked. Please ensure that
your joinery is protected right through the entire construction process.
External - Maintenance Program:
To extend the life of external powder coated articles and to comply with warranty
requirements for powder coated aluminium joinery, a simple, regular
maintenance program must be implemented.
The effects of ultra violet light, atmospheric pollution, dirt, grime and
airborne salt deposits will all accumulate over time and must be removed
or surface staining and weathering will occur, leading to an unsightly appearance.
For external coatings, cleaning should take place every six months. ln areas
where pollutants are more prevalent, such as beachfront houses and
industrial or geothermal areas, then a cleaning program should be carried
out on a more frequent basis ie. every one to three months.
Fences or Balustrades in close proximity to swimming pools must be washed down
every six months, to clean off chlorine and salt deposits.
Cleaning your powder coating:
1. Carefully remove any loose surface deposits with a wet sponge.
2. Use a soft brush (non abrasive) and a mild household detergent (do
not use solvents) in warm water, remove dust, salt and other deposits.
3. Rinse off with clean fresh water.
Restoring weathered or scratched surfaces:
Repair of Scuffed or Scratched surfaces
Dulux Spray Cans are available in all colour card colours.
Repair of Small Scratches or Chips.
Dulux Dabsticks are ideally suited for the repair of small scratches.
Dabsticks may not be available in all colour card colours.
Repair of Weathered areas .
Dulux Gloss Up is a light to medium cutting cream ideally
suited for gloss restoration and has been specifically designed for this purpose.
Gloss Up contains no waxes or silicone and is a one step system.
Typical sticker used to warn
other trades of the need to
protect and mask off
powder coated joinery
(applies to anodised joinery also)
Contact Dulux Powder Coatings , ph 0064 9 441 8244
Powder Coating Maintenance
Powder Coating Installation Care
®Juralco EDGE Balustrade Systems - Powder Coating Care and Maintenance
top related