irmp 5 year plan irmp presentation (5 year plan) 4 september 2006 this presentation is subject to...
Post on 13-Dec-2015
217 Views
Preview:
TRANSCRIPT
IRMP 5 YEAR PLAN
IRMP PRESENTATION (5 YEAR PLAN)
4 SEPTEMBER 2006
This presentation is subject to change.
IRMP 5 YEAR PLAN
• Local standards for Dwelling Fires and Road Traffic Collisions (RTC’s) agreed by CFA.
RESPONSE STANDARDS• DWELLING FIRESThe Royal Berkshire Fire and Rescue Service is committed to
achieving an optimum response standard of 8 minutes for the first
appliance and 10 minutes for the second appliance for dwelling
fires.
The Royal Berkshire Fire and Rescue Service is committed to
a standard response of 10 minutes for the first appliance and 12
minutes for the second appliance for dwelling fires.
The higher risk localities where it is predicted that appliances will
not reach dwelling fires within the standard response be prioritised
for community safety initiatives to drive down the risk.
ROAD TRAFFIC COLLISIONS
• The Royal Berkshire Fire and Rescue Service is committed to making an initial attendance to road traffic collisions, with the necessary resources to commence extrication of casualties, within 11 minutes.
IRMP 5 YEAR PLAN
• In addition, the CFA agreed to the re-deployment of the Incident Command Unit (ICU) from Windsor to Maidenhead and to crew the appliance with Retained Duty System Crews from Maidenhead and Cookham.
IRMP 5 YEAR PLAN
• Following strategies will result in efficiency savings that can be re-invested to improve RBFRS performance against the standards set for dwelling fires and RTC’s.
• Improve performance within existing budget (Doing more with the same).
IRMP 5 YEAR PLAN: KEY STRATEGIES
• Cookham
• Sonning and Wargrave
• Windsor
• Wokingham
• Crowthorne and Camberley
• Dee Road and Caversham Road
FIRE RELATED INCIDENTS ATTENDED BY COOKHAM
FDR1
0
50
100
150
200
250
300
350
Cookh
am
Warg
rave
Lam
bourn
Pangb
ourn
e
Sonnin
g
Hunge
rford
Mor
timer
Ascot
Crowth
orne
Wokin
gham
Win
dsor
Wokin
gham
Rd
Whitle
y Woo
d
Lang
ley
Caver
sham
Rd
Mai
denh
ead
Newbu
ry
Brack
nell
Dee R
d
Sloug
h
COOKHAM
• Work has commenced to review the range of equipment that the smaller appliance (4x4 Sprinter) will carry. In conjunction with this work, and following proper risk assessments, a decision will be made as to the category of incidents that this appliance will respond to.
IRMP 5 YEAR PLAN
• Planning assumptions based on:
7 years data for incident distribution and
3 years data for demand levels and turn
out times.
Run H1b
SloughSloughSloughSloughSloughSloughSloughSloughSlough
BracknellBracknellBracknellBracknellBracknellBracknellBracknellBracknellBracknell
AscotAscotAscotAscotAscotAscotAscotAscotAscotWokinghamWokinghamWokinghamWokinghamWokinghamWokinghamWokinghamWokinghamWokingham
Wokingham RoadWokingham RoadWokingham RoadWokingham RoadWokingham RoadWokingham RoadWokingham RoadWokingham RoadWokingham RoadDee RoadDee RoadDee RoadDee RoadDee RoadDee RoadDee RoadDee RoadDee Road
2,1402,1402,1402,1402,1402,1402,1402,1402,140
2,3662,3662,3662,3662,3662,3662,3662,3662,366
2,2642,2642,2642,2642,2642,2642,2642,2642,264
2,0542,0542,0542,0542,0542,0542,0542,0542,054
1,0621,0621,0621,0621,0621,0621,0621,0621,062
Caversham RoadCaversham RoadCaversham RoadCaversham RoadCaversham RoadCaversham RoadCaversham RoadCaversham RoadCaversham Road
New buryNew buryNew buryNew buryNew buryNew buryNew buryNew buryNew buryHungerfordHungerfordHungerfordHungerfordHungerfordHungerfordHungerfordHungerfordHungerford
LambournLambournLambournLambournLambournLambournLambournLambournLambourn
PangbournePangbournePangbournePangbournePangbournePangbournePangbournePangbournePangbourneSonningSonningSonningSonningSonningSonningSonningSonningSonning
WargraveWargraveWargraveWargraveWargraveWargraveWargraveWargraveWargrave
MortimerMortimerMortimerMortimerMortimerMortimerMortimerMortimerMortimer
CookhamCookhamCookhamCookhamCookhamCookhamCookhamCookhamCookham
WindsorWindsorWindsorWindsorWindsorWindsorWindsorWindsorWindsor
Crow thorneCrow thorneCrow thorneCrow thorneCrow thorneCrow thorneCrow thorneCrow thorneCrow thorne
LangleyLangleyLangleyLangleyLangleyLangleyLangleyLangleyLangley
MaidenheadMaidenheadMaidenheadMaidenheadMaidenheadMaidenheadMaidenheadMaidenheadMaidenhead
Whitley WoodWhitley WoodWhitley WoodWhitley WoodWhitley WoodWhitley WoodWhitley WoodWhitley WoodWhitley Wood
453453453453453453453453453
Wholetime Appliances (11)
Retained Appliances (10)
Current Station
OGRE Optimisation H1bWT: Fix 2 Slough, 2 Bracknell, Maidenhead, Newbury, Whitley Wood, 2 Cav.Rd. + 2WTR: Fix Lambourne, Hungerford, Newbury, Maidenhead, Ascot, Wokingham + 4R
2
2
Sonning
• Closure of Sonning Fire Station.• Redeployment of Personnel.Transfer to Wargrave Fire StationOpportunities to transfer on to 24 hour shift systemOpportunities to work within a ‘bank’ system (Ops or CommunitySafety) Redundancy
• Medium Term: Closure of Wargrave and build new station at Twyford.
WINDSOR
• Review of emergency cover in the Windsor area.
• Original proposal involved moving the Pump from Windsor to Wokingham or Bracknell.
• CFA have given direction that they wish to see other proposals that retain a fire and rescue presence in Windsor.
Slough Appliances attending Incidents in Windsor
• Random selection of incidents attended by Slough appliances in Windsor.
• From a total of 71 emergency journeys, all were on weekdays and 26 were during 0700-0900, and 1700-1800 hours.
• 87.3 % (62) were within 8 minutes.
• 91.5% (65) were within 10 minutes.
Slough Appliances attending Incidents in Windsor (additional data requested).
All calls attended by Slough appliances in the Windsor area: 1 April 2004 - 31 March 2006.
• Total calls in last two years = 389• Total journeys in last two years = 509• Journeys in 8 mins or less = 475 (93.3%)• Journeys in 10 mins or less = 493 (96.8%)
Calls attended between 0700-0900 & 1700-1800, weekdays only, excluding bank holidays and school holidays.
• Total calls = 30• Total journeys = 38• Journeys in 8 mins or less = 36 (94.7%)• Journeys in 10 mins or less = 36 (94.7%)
WINDSOR
Crewing Options• 24 hour crew (present system)• 12 hour cover (Slough cover outside hours 0800-
2000)• 12 hour plus Retained duty system• Retained duty system only
Location• Town Centre area
WINDSOR
Windsor pump calls 2004/05 2005/06
0
10
20
30
40
50
60
1 3 5 7 9 11 13 15 17 19 21 23
Hours
Nu
mb
er o
f ca
lls
Windsor pump calls p.a.
Windsor pump calls onown ground p.a.
WINDSOR
• If full-time cover is provided for between 0800 and 2000 hours at Windsor, average number of calls to absorb in Windsor would be 3 a week between 2000 and 0800 hours.
• Total number of calls per week (on average) between 2000 and 0800 attended by Windsor’s pump, anywhere in the County is 5.
WOKINGHAM
• Reinvest savings from other strategies to achieve a 24 hour crewed station or two 12 hour shift watches with cover outside these shifts by RDS firefighters. Say, cover from 0800 to 2000 hours every day with RDS outside these hours.
CROWTHORNE• Pinzgauer to be redeployed to Cookham.
• Trial the use of Camberley’s pumps into the southern part of Crowthorne’s ground to monitor effect on response standards.
• Possibilities for future improvements in emergency cover by utilising Pumps at Bracknell, Camberley and Wokingham to cover the Crowthorne area.
DEE ROAD AND CAVERSHAM ROAD
• Closure of Dee Road Fire Station.• Pump from Dee Road redeployed to Caversham
Road. • Transfer of 24 personnel to enable 13 per watch.• Crewing of pumps 5 and 5.• A small satellite fire station to be opened in
Calcot/Theale area with one pump between 1600-2000 hours.
2007 2008 2009
Cookham
Sonning
Windsor Option 3
20112010 2012
Crowthorne Trial
Wok’hamOption 1
Wargrave
Twyford
Dee Road
Cav Road
Wok’ham Option 2
BHQ?
RCC?
IRMP – 5 Year Strategic Plan
Crowthorne?