ip projectwise - cad qa check list
Post on 05-Jul-2018
214 Views
Preview:
TRANSCRIPT
IP ProjectWise – CADQA Check List
This is a guidance document providing a check list for CAD file Suppliers to ensure compliancy to the NHE BIM, CAD Information
Management Standard and associated references.
CAD File Specification Compliancy - Mandatory
1. CAD file delivered in .DGN
Pass Fail
2. CAD file Global Origin of 2D and 3D CAD model files shall be X=214748.3648, Y=214748.3648, Z=214748.3648
Pass Fail
3. CAD file Global Origin of CAD drawing files shall be X=0, Y=0
Pass Fail
4. CAD file Working Units, Master Unit: Metres, Sub Units: Millimetres, Accuracy: 0.1234
Pass Fail
5. CAD file Angles Format: DD.DDDD, Mode: Conventional, Accuracy: 0.1234
Pass Fail
6. CAD file only contains Model, Titleblock View and, where applicable, a Key Plan view
Pass Fail
7. ProjectWise Attribute Interface attributes reflect what is stored in the CAD file without manipulation of the Tag-set
Pass Fail
Total pass out of 7
CAD File Specification Compliancy - Advisory
1. CAD file reference display, all attached references displayed upon delivered to the Client
Pass Fail
2. CAD file reference display, all files not displayed detached upon delivery to the Client
Pass Fail
3. CAD file reference file Snap on
Pass Fail
4. CAD file reference file Locate on
Pass Fail
5. CAD file reference file Treat Attachment as Element for Manipulation off
Pass Fail
6. CAD file reference file True Scale on
Pass Fail
7. CAD file contains no Shared Cells
Pass Fail
8. CAD file contains no Nested Cells
Pass Fail
9. CAD file contains only cells that are approved and stored in the Cell Library in the PW
Pass Fail
10. CAD file utilises the Text
Pass Fail
Total pass out of 10
IP PROJECTWISE – SIGNED PDF PROCESS PAGE 2
CAD File Visual Compliancy - Mandatory
1. CAD file contains necessary copyright cell
Pass Fail
2. CAD file reference files missing as shown in red in MicroStation reference dialogue are detached
Pass Fail
3. CAD 2D and 3D CAD model file elements drawn at 1:1 scale not including schematics
Pass Fail
4. CAD drawing files display relevant scale
Pass Fail
5. CAD file elements drawn on the relevant geographical grid system
Pass Fail
6. CAD drawing file correctly and accurately reflects any plot or print to other file format without manipulation of output
Pass Fail
7. CAD file level names as per the Dgnlibs stored in PW
Pass Fail
Total pass out of 7
CAD File Visual Compliancy - Advisory
1. Incorrect file number displayed
Pass Fail
2. Ordnance Survey file colour and weight correct
Pass Fail
3. Incorrect Tag-set used
Pass Fail
4. Incorrect North point
Pass Fail
5. Use of None-Standard line style and or font
Pass Fail
6. CAD file Colour Code correct
Pass Fail
Total pass out of 6
top related