IP ProjectWise – CADQA Check List

This is a guidance document providing a check list for CAD file Suppliers to ensure compliancy to the NHE BIM, CAD Information

Management Standard and associated references.

CAD File Specification Compliancy - Mandatory

1. CAD file delivered in .DGN

Pass Fail

2. CAD file Global Origin of 2D and 3D CAD model files shall be X=214748.3648, Y=214748.3648, Z=214748.3648

Pass Fail

3. CAD file Global Origin of CAD drawing files shall be X=0, Y=0

Pass Fail

4. CAD file Working Units, Master Unit: Metres, Sub Units: Millimetres, Accuracy: 0.1234

Pass Fail

5. CAD file Angles Format: DD.DDDD, Mode: Conventional, Accuracy: 0.1234

Pass Fail

6. CAD file only contains Model, Titleblock View and, where applicable, a Key Plan view

Pass Fail

7. ProjectWise Attribute Interface attributes reflect what is stored in the CAD file without manipulation of the Tag-set

Pass Fail

Total pass out of 7

CAD File Specification Compliancy - Advisory

1. CAD file reference display, all attached references displayed upon delivered to the Client

Pass Fail

2. CAD file reference display, all files not displayed detached upon delivery to the Client

Pass Fail

3. CAD file reference file Snap on

Pass Fail

4. CAD file reference file Locate on

Pass Fail

5. CAD file reference file Treat Attachment as Element for Manipulation off 

Pass Fail

6. CAD file reference file True Scale on

Pass Fail

7. CAD file contains no Shared Cells

Pass Fail

8. CAD file contains no Nested Cells

Pass Fail

9. CAD file contains only cells that are approved and stored in the Cell Library in the PW

Pass Fail

10. CAD file utilises the Text

Pass Fail

Total pass out of 10

 

IP PROJECTWISE – SIGNED PDF PROCESS PAGE  2 

CAD File Visual Compliancy - Mandatory

1. CAD file contains necessary copyright cell

Pass Fail

2. CAD file reference files missing as shown in red in MicroStation reference dialogue are detached

Pass Fail

3. CAD 2D and 3D CAD model file elements drawn at 1:1 scale not including schematics

Pass Fail

4. CAD drawing files display relevant scale

Pass Fail

5. CAD file elements drawn on the relevant geographical grid system

Pass Fail

6. CAD drawing file correctly and accurately reflects any plot or print to other file format without manipulation of output

Pass Fail

7. CAD file level names as per the Dgnlibs stored in PW

Pass Fail

Total pass out of 7

CAD File Visual Compliancy - Advisory

1. Incorrect file number displayed

Pass Fail

2. Ordnance Survey file colour and weight correct

Pass Fail

3. Incorrect Tag-set used

Pass Fail

4. Incorrect North point

Pass Fail

5. Use of None-Standard line style and or font

Pass Fail

6. CAD file Colour Code correct

Pass Fail

Total pass out of 6