Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
RADIOACTIVITY
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Ag-110m glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2001
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ag-110m glass ampoule 2.7 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2003
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber, balance
5.00E+04 5.00E+07 Bq Ag-110m glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2002
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
1.00E+02 1.00E+06 Bq g-1 Am-241 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2004
Approved on
21 September
2016
ActivitySingle nuclide,
solid source
Defined solid angle
a-particle counting
standard
1.00E+01 3.00E+04 Bq Am-241electrodeposited
source0.5 % 2 ~95% Yes
Defined solid
angle a-particle
counting
standard
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2005
Approved on
21 September
2016
Activity
Multiple
nuclide, solid
source
Defined solid angle
a-particle counting
standard
4.00E+01 3.00E+04 Bq Am-241
multiple nuclide
electrodeposited
source
0.5 % 2 ~95% Yes
Defined solid
angle a-particle
counting
standard
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2006
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+04 1.00E+06 Bq Am-241 point solid source 1.2 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2007
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+08 Bq g-1 Au-198 glass ampoule 1 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2008
Approved on
21 September
2016
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
The BIPM key comparison database, September 2016 1/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity Single nuclide
solution
Secondary
standard ionisation
chamber, balance
5.00E+04 5.00E+08 Bq Au-198 glass ampoule 1 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2009
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+08 Bq g-1 Ba-133 glass ampoule 0.5 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2010
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ba-133 glass ampoule 2.5 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2012
Approved on
21 September
2016
Activity
Solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Ba-133 point solid source 1.2 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2013
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+11 Bq Ba-133 glass ampoule 0.9 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2011
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
4πβ-γ-coincidence
counting, standard
weighing set
4.00E+00 1.00E+02 Bq g-1 Ba-140 glass ampoule 0.5 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2014
Approved on
21 September
2016
Activity Single nuclide
solution
4πβ-γ-coincidence
counting4.00E+00 1.00E+02 Bq Ba-140 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2015
Approved on
21 September
2016
The BIPM key comparison database, September 2016 2/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+01 1.00E+07 Bq g-1 Bi-207 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2016
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 C-11 glass ampoule 2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2017
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 2.00E+11 Bq C-11 glass ampoule 2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2018
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution (pure
beta particle
emitter)
Liquid scintillation
counting, balance1.00E+02 1.00E+07 Bq g
-1 C-14 glass ampoule 1.4 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2019
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution (pure
beta particle
emitter)
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 C-14 glass ampoule 2.2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2020
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 C-14 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2021
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g
-1 Ca-45 glass ampoule 1.7 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2022
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
4.00E+04 1.00E+07 Bq g-1 Cd-109 glass ampoule 2.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2023
Approved on
21 September
2016
The BIPM key comparison database, September 2016 3/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Cd-109 glass ampoule 3.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2024
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+04 1.00E+06 Bq
Cd-109/Ag-
109mpoint solid source 1.7 % 2 ~95% Yes
4π(x,e)γ
coincidence
counting, TDCR
liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2025
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+06 Bq g-1 Ce-139 glass ampoule 1.4 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2026
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ce-139 glass ampoule 2.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2028
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+06 Bq Ce-139 glass ampoule 1.4 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2027
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Ce-139 point solid source 1 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2029
Approved on
21 September
2016
Activity per
unit mass
Single nuclide,
solid source
(gamma ray
detectors)
Secondary
standard ionisation
chamber, balance
2.00E+04 1.00E+07 Bq g-1 Ce-141 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2030
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ce-141 glass ampoule 2.2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2032
Approved on
21 September
2016
The BIPM key comparison database, September 2016 4/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Ce-141 point solid source 0.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2033
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
2.00E+04 5.00E+07 Bq Ce-141 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2031
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 5.00E+07 Bq g-1 Ce-144 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2034
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ce-144 glass ampoule 2.4 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2036
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+08 Bq Ce-144 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2035
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Ce-144 point solid source 2.4 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2037
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance2.00E+00 1.00E+07 Bq g
-1 Cl-36 glass ampoule 1.7 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2038
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Cl-36 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2039
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Defined solid angle
a-particle counting
standard
1.00E+05 1.00E+06 Bq g-1 Cm-244 glass ampoule 0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2040
Approved on
21 September
2016
The BIPM key comparison database, September 2016 5/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
ActivitySingle nuclide,
solid source
Defined solid angle
a-particle counting
standard
1.00E+01 3.00E+04 Bq Cm-244electrodeposited
source0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2041
Approved on
21 September
2016
Activity
Multiple
nuclide, solid
source
Defined solid angle
a-particle counting
standard
4.00E+01 3.00E+04 Bq Cm-244
multiple nuclide
electrodeposited
source
0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2206
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Co-56 glass ampoule 0.8 % 2 ~95% Yes
4πγ-counting,
4πβγ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2042
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Co-56 glass ampoule 2.2 % 2 ~95% Yes
4πγ-counting,
4πβγ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2044
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Co-56 glass ampoule 0.8 % 2 ~95% Yes
4πγ-counting,
4πβγ
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2043
Approved on
21 September
2016
Activity per
unit mass
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Co-56 point solid source 2.2 % 2 ~95% Yes
4πγ-counting,
4πβγ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2045
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 7.00E+09 Bq g-1 Co-57 glass ampoule 1.1 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2046
Approved on
21 September
2016
The BIPM key comparison database, September 2016 6/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Co-57 glass ampoule 2.2 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2046
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Co-57 point solid source 1.2 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2049
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+10 Bq Co-57 glass ampoule 1.1 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2047
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+06 Bq g-1 Co-58 glass ampoule 0.4 % 2 ~95% Yes
4π(x,β+)γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2050
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Co-58 glass ampoule 2.2 % 2 ~95% Yes
4π(x,β+)γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2052
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+06 Bq Co-58 glass ampoule 0.4 % 2 ~95% Yes4π(x,β
+)γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2051
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer4.00E+00 1.00E+06 Bq Co-58 point solid source 2.2 % 2 ~95% Yes
4π(x,β+)γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2053
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Co-60 glass ampoule 0.3 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2054
Approved on
21 September
2016
The BIPM key comparison database, September 2016 7/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Co-60 glass ampoule 1.8 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2056
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Co-60 point solid source 0.8 % 2 ~95% Yes
proportional
counter of the
4pbg
coincidence
system
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2058
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Co-60 point solid source 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2059
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Co-60 glass ampoule 0.3 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2055
Approved on
21 September
2016
Activity per
unit mass
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+06 Bq g-1 Co-60 point solid source 1.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2057
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
5.00E+04 1.00E+09 Bq g-1 Cr-51 glass ampoule 0.7 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2060
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Cr-51 glass ampoule 2 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2060
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+04 1.00E+06 Bq Cr-51 point solid source 0.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2063
Approved on
21 September
2016
The BIPM key comparison database, September 2016 8/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
5.00E+04 5.00E+09 Bq Cr-51 glass ampoule 0.7 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2061
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 5.00E+07 Bq g-1 Cs-134 glass ampoule 0.5 % 2 ~95% Yes
4πγ counting,
4πβγ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2064
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Cs-134 glass ampoule 2.2 % 2 ~95% Yes
4πγ counting,
4πβγ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2064
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Cs-134 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2068
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+09 Bq Cs-134 glass ampoule 0.5 % 2 ~95% Yes
4πγ counting,
4πβγ -
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2065
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer4.00E+00 1.00E+06 Bq Cs-134 point solid source 2.2 % 2 ~95% Yes
4πγ counting,
4πβγ -
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2067
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 5.00E+07 Bq g-1 Cs-137 glass ampoule 0.7 % 2 ~95% Yes
4πβγ-
coincidence
efficiency tracer
counting,TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2069
Approved on
21 September
2016
The BIPM key comparison database, September 2016 9/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Cs-137 glass ampoule 2.2 % 2 ~95% Yes
4πβγ-
coincidence
efficiency tracer
counting, TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2071
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+09 Bq Cs-137 glass ampoule 0.7 % 2 ~95% Yes
4πβγ-
coincidence
efficiency tracer
counting,TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2070
Approved on
21 September
2016
Activity Single nuclide
solution
Gamma ray
spectrometer4.00E+00 1.00E+06 Bq Cs-137 glass ampoule 2.2 % 2 ~95% Yes
4πβγ-
coincidence
efficiency tracer
counting,TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2072
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Cs-137/Ba-
137mpoint solid source
1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2073
Approved on
21 September
2016
The BIPM key comparison database, September 2016 10/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq
Cs-137/Ba-
137mpoint solid source 0.9 % 2 ~95% Yes
4πβγ-
coincidence
efficiency tracer
counting,TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2074
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 7.00E+09 Bq g-1 Cu-64 glass ampoule 1.6 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2075
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+10 Bq Cu-64 glass ampoule 1.6 % 2 ~95% Yes
TDCR liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2076
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+09 Bq g-1 Eu-152 glass ampoule 0.4 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2078
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Eu-152 glass ampoule 2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2080
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+10 Bq Eu-152 glass ampoule 0.7 % 2 ~95% Yes 4πβγ counting LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2079
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer4.00E+00 1.00E+06 Bq Eu-152 point solid source 2 % 2 ~95% Yes 4πβγ counting LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2081
Approved on
21 September
2016
The BIPM key comparison database, September 2016 11/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+01 1.00E+09 Bq g-1 F-18 glass ampoule 2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2082
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+01 5.00E+09 Bq F-18 glass ampoule 2 % 2 ~95% Yes
TDCR liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2083
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E-02 1.00E+06 Bq g
-1 Fe-55 glass ampoule 2.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2084
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
TDCR liquid
scintillation
counting, balance
1.00E+03 1.00E+06 Bq g-1 Fe-55 glass ampoule 1 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2085
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Fe-59 glass ampoule 0.8 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2086
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Fe-59 glass ampoule 3.2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2088
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Fe-59 glass ampoule 0.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2087
Approved on
21 September
2016
Activity
Solid source
(gamma ray
detectors)
Gamma ray
spectrometer5.00E-01 1.00E+07 Bq Fe-59 point solid source 0.4 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2089
Approved on
21 September
2016
The BIPM key comparison database, September 2016 12/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 5.00E+08 Bq g-1 Ga-67 glass ampoule 1.2 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2090
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+10 Bq Ga-67 glass ampoule 1.2 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2091
Approved on
21 September
2016
Efficiency of
ionisation
chambers
Ionisation
chamberSubstitution 2.00E-18 1.00E-08 A Bq
-1
g-ray
emitting
nuclide
all kinds of
containers0.2 % 2 ~95% Yes
Depending on
radionuclideLNE-LNHB
EUR-RAD-
LNE-
LNHB-
2092
Approved on
21 September
2016
Efficiency of
ionisation
chambers
Radionuclide
calibrator
(ionisation
current versus
activity)
Substitution 1.00E-13 1.00E-07 A Bq-1
g-ray
emitting
nuclide
geometry used in
nuclear medicine2 % 2 ~95% Yes
Depending on
radionuclideLNE-LNHB
EUR-RAD-
LNE-
LNHB-
2093
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution (pure
beta particle
emitter)
Liquid scintillation
counting, balance1.00E+02 1.00E+07 Bq g
-1 H-3 tritiated water 2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2094
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution (pure
beta particle
emitter)
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 H-3 tritiated water 2.2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2095
Approved on
21 September
2016
Activity per
unit volume
Single nuclide
gas
Differential
proportional
counter, standard
volume set
1.00E+01 4.00E+07 Bq cm-3 H-3
Hydrogen gas in
glass ampoule or in
metallic bottles
3 % 2 ~95% Yes
Differential
proportional
counter,
standard volume
set
LNE-LNHB,
LNE
(volume)
EUR-RAD-
LNE-
LNHB-
2096
Approved on
21 September
2016
The BIPM key comparison database, September 2016 13/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+05 Bq g-1 Ho-166m glass ampoule 0.7 % 2 ~95% Yes
4πβγ-
anticoincidence
counting, TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2097
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ho-166m glass ampoule 2.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting, TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2099
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+05 Bq Ho-166m glass ampoule 0.7 % 2 ~95% Yes
4πβγ-
anticoincidence
counting, TDCR
liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2098
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer4.00E+00 1.00E+07 Bq Ho-166m point solid source 2.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting, TDCR
liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2100
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+09 Bq g-1 I-123 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2101
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+09 Bq I-123 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2102
Approved on
21 September
2016
The BIPM key comparison database, September 2016 14/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+09 Bq g-1 I-125 glass ampoule 1.2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2103
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+09 Bq I-125 glass ampoule 3 % 2 ~95% Yes
TDCR liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2104
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
4.00E+04 5.00E+05 Bq g-1 I-129 glass ampoule 2 % 2 ~95% Yes
4π(LS)βγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2105
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
4.00E+04 1.00E+07 Bq I-129 glass ampoule 2 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2106
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 I-131 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2107
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 I-131 glass ampoule 1.8 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2109
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer4.00E+00 1.00E+07 Bq I-131 point solid source 1.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2110
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq I-131 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2108
Approved on
21 September
2016
The BIPM key comparison database, September 2016 15/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+09 Bq g-1 In-111 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2111
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+09 Bq In-111 glass ampoule 0.5 % 2 ~95% Yes 4πβγ-counting LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2112
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance,
gamma ray
spectrometer
1.00E+04 1.00E+09 Bq g-1 Ir-192 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2113
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ir-192 glass ampoule 2.8 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2115
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber, gamma
ray spectrometer
1.00E+04 5.00E+09 Bq Ir-192 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2114
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer4.00E+00 1.00E+07 Bq Ir-192 point solid source 2.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2116
Approved on
21 September
2016
Activity per
unit volume
Single nuclide
gas
Differential
proportional
counter, standard
volume set
1.00E+01 4.00E+07 Bq cm-3 Kr-85
Krypton gas in glass
ampoule or in
metallic bottles
1 % 2 ~95% Yes
Differential
proportional
counter,
standard volume
set
LNE-LNHB,
LNE
(volume)
EUR-RAD-
LNE-
LNHB-
2117
Approved on
21 September
2016
The BIPM key comparison database, September 2016 16/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Lu-177 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting, TDCR
liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2118
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Lu-177 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting, TDCR
liquid
scintillation
counting.
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2119
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Mn-54 glass ampoule 0.7 % 2 ~95% Yes
4π(x,e)γ-anti
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2120
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Mn-54 glass ampoule 1.8 % 2 ~95% Yes
4π(x,e)γ-anti
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2122
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Mn-54 point solid source 0.8 % 2 ~95% Yes
4π(x,e)γ-anti
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2123
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Mn-54 glass ampoule 0.7 % 2 ~95% Yes
4π(x,e)γ-anti
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2121
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+08 Bq g-1 Mn-56 glass ampoule 1 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2124
Approved on
21 September
2016
The BIPM key comparison database, September 2016 17/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+08 Bq Mn-56 glass ampoule 1 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2125
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+09 Bq g-1 Mo-99/Tc-
99mglass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2126
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+09 Bq Mo-99/Tc-
99mglass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2127
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Na-22 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2128
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Na-22 glass ampoule 2.2 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2130
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Na-22 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2131
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Na-22 point solid source 0.8 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2132
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Na-22 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2129
Approved on
21 September
2016
The BIPM key comparison database, September 2016 18/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Na-24 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2133
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Na-24 glass ampoule 0.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2134
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+06 Bq g-1 Nb-95 glass ampoule 0.4 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2135
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Nb-95 glass ampoule 2.2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2137
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+06 Bq Nb-95 glass ampoule 0.4 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2136
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+07 Bq Nb-95 point solid source 2.2 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2138
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
4πβ-γ-coincidence
counting4.00E+00 1.00E+07 Bq Nb-95 point solid source 2.2 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2139
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g
-1 Ni-63 glass ampoule 1 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2140
Approved on
21 September
2016
The BIPM key comparison database, September 2016 19/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance4.00E+00 1.00E+02 Bq g
-1 Ni-63 glass ampoule 3.2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2141
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g
-1 Np-237 glass ampoule 1 % 2 ~95% Yes
Defined solid
angle α-particle
counting, 4παγ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2142
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
4.00E+04 4.00E+07 Bq g-1 P-32 glass ampoule 1.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2143
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
4.00E+04 1.00E+09 Bq P-32 glass ampoule 1.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2144
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
4.00E+04 1.00E+06 Bq g-1 Pb-210 glass ampoule 1.5 % 2 ~95% Yes
4π(LS)βγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2145
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
4.00E+04 1.00E+07 Bq Pb-210 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2146
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g
-1 Pm-147 glass ampoule 1.7 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2147
Approved on
21 September
2016
The BIPM key comparison database, September 2016 20/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 Pm-147 glass ampoule 2.2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2148
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Pm-147 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2149
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g
-1 Pu-238 glass ampoule 0.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2150
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 Pu-238 glass ampoule 1.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2151
Approved on
21 September
2016
ActivitySingle nuclide,
solid source
Defined solid angle
a-particle counting
standard
1.00E+01 3.00E+04 Bq Pu-238electrodeposited
source0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2152
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Defined solid angle
a-particle counting
standard
1.00E+02 1.00E+06 Bq g-1 Pu-239 glass ampoule 0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2153
Approved on
21 September
2016
ActivitySingle nuclide,
solid source
Defined solid angle
a-particle counting
standard
1.00E+01 3.00E+04 Bq Pu-239electrodeposited
source0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2154
Approved on
21 September
2016
Activity
Multiple
nuclide, solid
source
Defined solid angle
a-particle counting
standard
4.00E+01 3.00E+04 Bq Pu-239
multiple nuclide
electrodeposited
source
0.5 % 2 ~95% Yes
Defined solid
angle α-particle
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2006
Approved on
21 September
2016
The BIPM key comparison database, September 2016 21/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g-1 Pu-241 glass ampoule 3.4 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2155
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Ru-103/Rh-
103mglass ampoule 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2156
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Ru-103/Rh-
103mglass ampoule 2.2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2158
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+04 1.00E+06 Bq
Ru-103/Rh-
103mpoint solid source 0.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2159
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Ru-103/Rh-
103mglass ampoule 0.6 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2157
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
4πβ-γ-coincidence
counting1.00E+04 1.00E+06 Bq Ru-106 point solid source 0.8 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2160
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+07 Bq g
-1 S-35 glass ampoule 2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2161
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 7.00E+09 Bq g-1 Sb-124 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2162
Approved on
21 September
2016
The BIPM key comparison database, September 2016 22/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+10 Bq Sb-124 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2163
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Sb-124 glass ampoule 0.6 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2164
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer5.00E-01 1.00E+07 Bq Sb-124 point solid source 0.6 % 2 ~95% Yes
4πβγ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2165
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 4.00E+08 Bq g-1 Se-75 glass ampoule 1 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2166
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Se-75 glass ampoule 2.3 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2168
Approved on
21 September
2016
ActivitySingle nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+10 Bq Se-75 glass ampoule 1 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2167
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer5.00E-01 1.00E+07 Bq Se-75 point solid source 2.3 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2169
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+09 Bq g-1 Sm-153 glass ampoule 0.4 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2170
Approved on
21 September
2016
The BIPM key comparison database, September 2016 23/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+10 Bq Sm-153 glass ampoule 0.4 % 2 ~95% Yes
TDCR liquid
scintillation
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2171
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Sr-85 glass ampoule 0.7 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2172
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Sr-85 glass ampoule 2.2 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2174
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Sr-85 point solid source 1.2 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2175
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Sr-85 glass ampoule 0.7 % 2 ~95% Yes
4π(x,e)-γ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2173
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+06 Bq g
-1 Sr-89 glass ampoule 0.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2176
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 Sr-89 glass ampoule 2.2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2177
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Sr-89 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2178
Approved on
21 September
2016
The BIPM key comparison database, September 2016 24/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Sr90/Y90 point solid source1.5 to
0.8% 2 ~95% Yes 4π (PC) LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2179
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 4.00E+07 Bq g
-1 Sr-90/Y-90 glass ampoule 2 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2180
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 Sr-90/Y-90 glass ampoule 2.1 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2181
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 7.00E+09 Bq g-1 Tc-99m glass ampoule 1.8 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2182
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
4πβ-γ-coincidence
counting1.00E+02 1.00E+07 Bq g
-1 Tc-99m glass ampoule 2 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2184
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 1.00E+10 Bq Tc-99m glass ampoule 1.8 % 2 ~95% Yes
4πβγ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2183
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
1.00E+00 8.00E+05 Bq g-1 Th-228 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2185
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Th-228 glass ampoule 3.2 % 2 ~95% Yes
4πβγ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2186
Approved on
21 September
2016
The BIPM key comparison database, September 2016 25/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
5.00E+04 1.00E+09 Bq g-1 Tl-201 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2187
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
5.00E+04 1.00E+09 Bq Tl-201 glass ampoule 1.5 % 2 ~95% Yes
4πβγ-
anticoincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2188
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+07 Bq g
-1 Tl-204 glass ampoule 1 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2189
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance2.00E+00 1.00E+02 Bq g
-1 Tl-204 glass ampoule 2.3 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2190
Approved on
21 September
2016
Surface
emission rate
Single nuclide,
solid source
4π proportional
counter3.00E+00 3.00E+03 s
-1 Tl-204 point solid source1.5 to
0.8% 2 ~95% Yes
4π proportional
countingLNE-LNHB
EUR-RAD-
LNE-
LNHB-
2191
Approved on
21 September
2016
Activity per
unit volume
Single nuclide
gas
Differential
proportional
counter, standard
volume set
1.00E+01 4.00E+07 Bq cm-3 Xe-133
Xenon gas in glass
ampoule or in
metallic bottles
2 % 2 ~95% Yes
Differential
proportional
counter,
standard volume
set
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2192
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Y-88 glass ampoule 0.8 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2193
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Y-88 glass ampoule 2.2 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2195
Approved on
21 September
2016
The BIPM key comparison database, September 2016 26/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Y-88 point solid source 1 % 2 ~95% Yes
4πβγ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2196
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Y-88 glass ampoule 0.8 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2194
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Liquid scintillation
counting, balance1.00E+02 1.00E+07 Bq g
-1 Y-90 glass ampoule 1.5 % 2 ~95% Yes
TDCR liquid
scintillation
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2197
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
4.00E+04 1.00E+07 Bq g-1 Yb-169 glass ampoule 0.5 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2198
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Yb-169 glass ampoule 2.8 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2200
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
4.00E+04 5.00E+07 Bq Yb-169 glass ampoule 0.5 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2199
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+03 1.00E+06 Bq Yb-169 point solid source 2.8 % 2 ~95% Yes
4πγ counting,
4πγ(x,e)-γ
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2201
Approved on
21 September
2016
Activity per
unit mass
Single nuclide
solution
Secondary
standard ionisation
chamber, balance
1.00E+04 1.00E+07 Bq g-1 Zn-65 glass ampoule 0.6 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2202
Approved on
21 September
2016
The BIPM key comparison database, September 2016 27/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Activity per
unit mass
Single nuclide
solution
Gamma ray
spectrometer,
balance
4.00E+00 1.00E+02 Bq g-1 Zn-65 glass ampoule 2.2 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting,
standard
weighing set
LNE-LNHB,
LNE (mass)
EUR-RAD-
LNE-
LNHB-
2204
Approved on
21 September
2016
Activity
Single nuclide,
solid source
(gamma ray
detectors)
Gamma ray
spectrometer1.00E+04 1.00E+06 Bq Zn-65 point solid source 0.8 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2205
Approved on
21 September
2016
Activity Single nuclide
solution
Secondary
standard ionisation
chamber
1.00E+04 5.00E+07 Bq Zn-65 glass ampoule 0.6 % 2 ~95% Yes
4π(x,e)-γ-
coincidence
counting
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2203
Approved on
21 September
2016
DOSIMETRY
Absorbed
dose in soft
tissue
Dosemeter
Calibration in a
calibrated field free
in air
2.0E-05 5.0E+00 GyBeta
radiation
ISO 6980, Pm-147,
Kr-85, Sr-90/Y-902.7 % 2 ~95% Yes
Primary
extrapolation
ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1001
Approved on
11 September
2013
Personal
dose
equivalent at
0.07 mm
depth
Personal
dosimeter
Calibration in a
calibrated field
using a phantom
2.0E-05 5.0E+00 SvBeta
radiation
ISO 6980, Pm-147,
Kr-85, Sr-90/Y-906.5 % 2 ~95% Yes
Primary
extrapolation
ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1002
Approved on
11 September
2013
Directional
dose
equivalent
Dosemeter
Calibration in a
calibrated field free
in air
2.0E-05 5.0E+00 SvBeta
radiation
ISO 6980, Pm-147,
Kr-85, Sr-90/Y-906.5 % 2 ~95% Yes
Primary
extrapolation
ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1003
Approved on
11 September
2013
Absorbed
dose rate in
soft tissue
Dosemeter
Calibration in a
calibrated field free
in air
7.0E-04 3.0E-01 Gy h-1 Beta
radiation
ISO 6980, Pm-147,
Kr-85, Sr-90/Y-902.7 % 2 ~95% Yes
Primary
extrapolation
ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1004
Approved on
11 September
2013
Directional
dose
equivalent
rate
Dosemeter
Calibration in a
calibrated field free
in air
7.0E-04 3.0E-01 Sv h-1 Beta
radiation
ISO 6980, Pm-147,
Kr-85, Sr-90/Y-906.5 % 2 ~95% Yes
Primary
extrapolation
ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1005
Approved on
11 September
2013
The BIPM key comparison database, September 2016 28/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeter
Calibration in a
calibrated field
using a phantom
7.0E-04 3.0E-01 Sv h-1 Beta
radiation
ISO 6980, Pm-147,
Kr-85, Sr-90/Y-906.5 % 2 ~95% Yes
Primary
extrapolation
ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1006
Approved on
11 September
2013
Reference air
kerma rate
Ir-192 source
(HDR)
Transfer cavity
chamber calibrated
againt primary
cavity chamber
1.0E-03 5.0E-02 Gy h-1 Ir-192
without scattered
radiation1.2 % 2 ~95% Yes
Transfer
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1007
Approved on
11 September
2013
Reference air
kerma rate
Well-type
ionization
chamber
Calibration in an Ir-
192 reference field1.0E-03 5.0E-02 Gy h
-1 Ir-192high dose rate,
pulsed dose rate1.3 % 2 ~95% Yes
Ir-192 reference
sourceLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1008
Approved on
11 September
2013
Air kerma
rateDosemeter
Calibration in a
calibrated field free
in air
1.0E+00 1.8E-02 Gy h-1 Co-60 therapy level 0.9 % 2 ~95% Yes
Graphite air
cavity ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1009
Approved on
11 September
2013
Air kerma Dosemeter
Calibration in a
calibrated field free
in air
5.0E-02 1.8E+03 Gy Co-60 therapy level 1.0 % 2 ~95% Yes
Graphite air
cavity ionisation
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1010
Approved on
11 September
2013
Air kerma
rateDosemeter
Calibration in a
calibrated field free
in air
1.0E-01 1.5E+00 Gy h-1 Cs-137 therapy level 0.9 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1011
Approved on
11 September
2013
Air kerma Dosemeter
Calibration in a
calibrated field free
in air
1.0E-02 3.0E+02 Gy Cs-137 therapy level 1.0 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1012
Approved on
11 September
2013
The BIPM key comparison database, September 2016 29/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Absorbed
dose rate to
water
Dosemeter
Calibration in a
calibrated field in
water phantom
1.0E+01 1.8E+02 Gy h-1 Co-60 therapy level 0.7 % 2 ~95% Yes
Absorbed dose
to graphite by
calorimetry and
transfer to
absorbed dose
to water based
on calculations
and absorbed
dose to water by
calorimetry
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1013
Approved on
11 September
2013
Absorbed
dose to waterDosemeter
Calibration in a
calibrated field in
water phantom
2.0E-01 1.8E+03 Gy Co-60 therapy level 0.5 % 2 ~95% Yes
Absorbed dose
to graphite by
calorimetry and
transfer to
absorbed dose
to water based
on calculations
and absorbed
dose to water by
calorimetry
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1014
Approved on
11 September
2013
Absorbed
dose to waterDosemeter
Calibration against
a transfer standard
in a water phantom
3.0E-01 3.0E+01 GyPhotons,
high energy
medical type
accelerator: 6 MV, 8
MV, 10 MV, 2 MV,
15 MV, 18 MV, 20
MV and 25 MV
(TPR from 0.675 to
0.785)
2.1 % 2 ~95% Yes
Co-60 absorbed
dose to water
and transfer to
beam quality
with ionisation
chambers and
Fricke
dosemeters
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1015
Approved on
11 September
2013
Absorbed
dose to waterDosemeter
Calibration against
a transfer standard
in a water phantom
3.0E-01 3.0E+01 GyElectrons,
high energy
medical type
accelerator: 9 MeV,
12 MeV and 18
MeV (R50 from 3.5
g/cm2 to 7.3 g/cm
2)
2.7 % 2 ~95% Yes
Co-60 absorbed
dose to water
and TRS 398
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1016
Approved on
11 September
2013
The BIPM key comparison database, September 2016 30/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Air kerma
rateDosemeter
Calibration in a
calibrated field free
in air
1.0E-06 1.0E+00 Gy h-1 Cs-137 ISO 4037 0.9 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1017
Approved on
11 September
2013
Air kerma Dosemeter
Calibration in a
calibrated field free
in air
1.0E-08 2.0E+02 Gy Cs-137 ISO 4037 1.0 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1018
Approved on
11 September
2013
Air kerma
rateDosemeter
Calibration in a
calibrated field free
in air
1.0E-06 1.0E+01 Gy h-1 Co-60 ISO 4037 0.9 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1019
Approved on
11 September
2013
Air kerma Dosemeter
Calibration in a
calibrated field free
in air
1.5E-08 2.0E+02 Gy Co-60 ISO 4037 1.0 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1020
Approved on
11 September
2013
Air kerma
ratePhoton beam
Cavity ionisation
chamber1.0E-01 2.0E+01 Gy h
-1 Cs-137collimated beam
(ISO 4037)0.6 % 2 ~95% Yes
Cs-137 beams
calibrated
against primary
standard
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1021
Approved on
11 September
2013
Air kerma
ratePhoton beam
Transfer ionisation
chamber1.0E-06 2.0E+01 Gy h
-1 Cs-137collimated beam
(ISO 4037)0.8 % 2 ~95% Yes
Cs-137 beams
calibrated
against primary
standard
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1022
Approved on
11 September
2013
The BIPM key comparison database, September 2016 31/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Air kerma
ratePhoton beam
Cavity ionisation
chamber1.0E-01 1.8E+02 Gy h
-1 Co-60
collimated beam
(ISO 4037 and
radiotherapy beam)
0.6 % 2 ~95% Yes
Co-60 beams
calibrated
against primary
standard
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1023
Approved on
11 September
2013
Air kerma
ratePhoton beam
Transfer ionisation
chamber1.0E-06 1.8E+02 Gy h
-1 Cs-137
collimated beam
(ISO 4037 and
radiotherapy beam)
0.8 % 2 ~95% Yes
Co-60 beams
calibrated
against primary
standard
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1024
Approved on
11 September
2013
Ambient
dose
equivalent
rate
Ambient
dosemeter
Calibration in a
calibrated field free
in air
1.0E-06 1.0E+00 Sv h-1 Cs-137 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1025
Approved on
11 September
2013
Ambient
dose
equivalent
Ambient
dosemeter
Calibration in a
calibrated field free
in air
1.5E-06 2.0E+02 Sv Cs-137 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1026
Approved on
11 September
2013
Ambient
dose
equivalent
rate
Ambient
dosemeter
Calibration in a
calibrated field free
in air
1.0E-06 1.0E+01 Sv h-1 Co-60 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1027
Approved on
11 September
2013
Ambient
dose
equivalent
Ambient
dosemeter
Calibration in a
calibrated field free
in air
1.5E-08 2.0E+02 Sv Co-60 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1028
Approved on
11 September
2013
The BIPM key comparison database, September 2016 32/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeter
Calibration in a
calibrated field
using a phantom
5.0E-07 1.0E+00 Sv h-1 Cs-137 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
2029
Approved on
11 September
2013
Personal
dose
equivalent at
10 mm depth
Personal
dosimeter
Calibration in a
calibrated field
using a phantom
1.0E-08 2.0E+02 Sv Cs-137 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1030
Approved on
11 September
2013
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeter
Calibration in a
calibrated field
using a phantom
1.0E-06 1.0E+01 Sv h-1 Co-60 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1031
Approved on
11 September
2013
Personal
dose
equivalent at
10 mm depth
Personal
dosimeter
Calibration in a
calibrated field
using a phantom
1.5E-08 2.0E+02 Sv Co-60 ISO 4037 4.2 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
transfer
chamber
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1032
Approved on
11 September
2013
Air kerma
rateRadiation field
Transfer
ESR/alanine
dosemeter
1.0E+01 1.0E+05 Gy h-1 Co-60
interpretation of
dosemeters
irradiated in
customer's field.
Conform to ISO
51607 (2004)
1.3 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
alanine transfer
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1033
Approved on
11 September
2013
The BIPM key comparison database, September 2016 33/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Air kerma Dosemeter
Calibration in a
calibrated
irradiation cavity
1.0E+02 1.0E+05 Gy Co-60
interpretation of
dosemeters
irradiated in
customer's field.
Conform to ISO
51607 (2004)
2.3 % 2 ~95% Yes
Primary
standard
graphite air
cavity ionisation
chamber and
alanine transfer
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1034
Approved on
11 September
2013
Absorbed
dose rateRadiation field
Transfer
ESR/alanine
dosemeter
1.0E+01 1.0E+05 Gy h-1 Co-60
interpretation of
dosemeters
irradiated in
customer's field.
Conform to ISO
51607 (2004)
1.1 % 2 ~95% Yes
Primary
standard
graphite
calorimeter and
alanine transfer
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1035
Approved on
11 September
2013
Absorbed
doseDosemeter
Calibration in a
calibrated
irradiation cavity
1.0E+02 1.0E+05 Gy Co-60
interpretation of
dosemeters
irradiated in
customer's field.
Conform to ISO
51607 (2004)
2.2 % 2 ~95% Yes
Primary
standard
graphite
calorimeter and
alanine transfer
LNE-LNHB
EUR-RAD-
LNE-
LNHB-
1036
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 30
kV to 50 kV
10 kV to 40 kV, ISO
4037 narrow series0.7 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1037
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 10
kV to 20 kV
10 kV to 20 kV, ISO
4037 narrow series1.3 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1038
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 narrow
series
0.7 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1039
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 20
kV to 50 kV
20 kV to 30 kV, ISO
4037 high dose rate
series
0.7 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1040
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 10
kV
10 kV, ISO 4037
high dose rate
series
1.3 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1041
Approved on
11 September
2013
The BIPM key comparison database, September 2016 34/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 high dose
rate series
0.7 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1042
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 25
kV to 50 kV
25 kV to 50 kV,
CCRI series0.7 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1043
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 10
kV10 kV, CCRI series 1.3 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1044
Approved on
11 September
2013
Air kerma
rateDosemeter Free air chamber 5.0E-06 1.0E-02 Gy s
-1 X-rays, 100
kV to 250 kV
100 kV to 250 kV,
CCRI series0.7 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1045
Approved on
11 September
2013
Air kerma Dosemeter Free air chamber 1.0E-05 1.5E-01 GyX-rays, 40
kV
40 kV, IEC 61267
RQR series0.8 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1046
Approved on
11 September
2013
Air kerma Dosemeter Free air chamber 1.0E-05 1.5E-01 GyX-rays, 50
kV to 150 kV
50 kV to 150 kV,
IEC 61267 RQR
series
0.8 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1047
Approved on
11 September
2013
Air kerma Dosemeter Free air chamber 5.0E-04 1.0E-01 GyX-rays, 10
kV to 50 kV
10 kV to 50 kV, IEC
61267 RQR-M
series
1.2 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1048
Approved on
11 September
2013
Ambient
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 10
kV to 50 kV
25 kV to 40 kV, ISO
4037 narrow series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1049
Approved on
11 September
2013
Ambient
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 narrow
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1050
Approved on
11 September
2013
The BIPM key comparison database, September 2016 35/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Ambient
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 high dose
rate series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1051
Approved on
11 September
2013
Ambient
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 10
kV to 50 kV
10 kV to 50 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1052
Approved on
11 September
2013
Ambient
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 100
kV to 250 kV
100 kV to 250 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1053
Approved on
11 September
2013
Ambient
dose
equivalent
Dosemeter Free air chamber 1.0E-05 1.5E-01 SvX-rays, 40
kV
40 kV. IEC 61267
RQR series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1054
Approved on
11 September
2013
Ambient
dose
equivalent
Dosemeter Free air chamber 1.0E-05 1.5E-01 SvX-rays, 50
kV to 150 kV
50 kV to 150 kV,
IEC 61267 RQR
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1055
Approved on
11 September
2013
Ambient
dose
equivalent
Dosemeter Free air chamber 5.0E-04 1.0E-01 SvX-rays, 10
kV to 50 kV
10 kV to 50 kV, IEC
61267 RQR-M
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1056
Approved on
11 September
2013
Directional
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 10
kV to 50 kV
10 kV to 40 kV, ISO
4037 narrow series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1057
Approved on
11 September
2013
Directional
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 narrow
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1058
Approved on
11 September
2013
Directional
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 10
kV to 50 kV
10 kV to 30 kV, ISO
4037 high dose rate
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1059
Approved on
11 September
2013
The BIPM key comparison database, September 2016 36/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Directional
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 high dose
rate series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1060
Approved on
11 September
2013
Directional
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 10
kV to 50 kV
10 kV to 50 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1061
Approved on
11 September
2013
Directional
dose
equivalent
rate
Dosemeter Free air chamber 5.0E-06 1.0E-02 Sv s-1 X-rays, 100
kV to 250 kV
100 kV to 250 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1062
Approved on
11 September
2013
Directional
dose
equivalent
Dosemeter Free air chamber 5.0E-06 1.5E-01 SvX-rays, 40
kV
40 kV, IEC 61267
RQR series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1063
Approved on
11 September
2013
Directional
dose
equivalent
Dosemeter Free air chamber 1.0E-05 1.5E-01 SvX-rays, 50
kV to 150 kV
50 kV to 150 kV,
IEC 61267 RQR
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1064
Approved on
11 September
2013
Directional
dose
equivalent
Dosemeter Free air chamber 1.0E-05 1.0E-01 SvX-rays, 10
kV to 50 kV
10 kV to 50 kV, IEC
61267 RQR-M
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1065
Approved on
11 September
2013
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 10
kV to 50 kV
10 kV to 40 kV, ISO
4037 narrow series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1066
Approved on
11 September
2013
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 narrow
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1067
Approved on
11 September
2013
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 high dose
rate series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1068
Approved on
11 September
2013
The BIPM key comparison database, September 2016 37/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 10
kV to 50 kV
10 kV to 50 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1069
Approved on
11 September
2013
Personal
dose
equivalent
rate at 10
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 100
kV to 250 kV
100 kV to 250 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1070
Approved on
11 September
2013
Personal
dose
equivalent at
10 mm depth
Personal
dosimeterFree air chamber 1.0E-05 1.0E-01 Sv
X-rays, 40
kV
40 kV, IEC 61267
RQR series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1071
Approved on
11 September
2013
Personal
dose
equivalent at
10 mm depth
Personal
dosimeterFree air chamber 1.0E-05 1.0E-01 Sv
X-rays, 50
kV to 150 kV
50 kV to 150 kV,
IEC 61267 RQR
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1072
Approved on
11 September
2013
Personal
dose
equivalent at
10 mm depth
Personal
dosimeterFree air chamber 1.0E-05 1.0E-01 Sv
X-rays, 10
kV to 50 kV
10 kV to 50 kV, IEC
61267 RQR-M
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1073
Approved on
11 September
2013
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 10
kV to 50 kV
10 kV to 40 kV, ISO
4037 narrow series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1074
Approved on
11 September
2013
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 narow
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1075
Approved on
11 September
2013
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 10
kV to 50 kV
10 kV to 30 kV, ISO
4037 high dose rate
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1076
Approved on
11 September
2013
The BIPM key comparison database, September 2016 38/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 50
kV to 320 kV
60 kV to 300 kV,
ISO 4037 high dose
rate series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1077
Approved on
11 September
2013
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 10
kV to 50 kV
10 kV to 50 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1078
Approved on
11 September
2013
Personal
dose
equivalent
rate at 0.07
mm depth
Personal
dosimeterFree air chamber 5.0E-06 1.0E-02 Sv s
-1 X-rays, 100
kV to 250 kV
100 kV to 250 kV,
CCRI series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1079
Approved on
11 September
2013
Personal
dose
equivalent at
0.07 mm
depth
Personal
dosimeterFree air chamber 1.0E-05 1.5E-01 Sv
X-rays, 40
kV
40 kV, IEC 61267
RQR series4.1 % 2 ~95% Yes
Free air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1080
Approved on
11 September
2013
Personal
dose
equivalent at
0.07 mm
depth
Personal
dosimeterFree air chamber 1.0E-05 1.5E-01 Sv
X-rays, 50
kV to 150 kV
50 kV to 150 kV,
IEC 61267 RQR
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1081
Approved on
11 September
2013
Personal
dose
equivalent at
0.07 mm
depth
Personal
dosimeterFree air chamber 1.0E-05 1.0E-01 Sv
X-rays, 10
kV to 50 kV
10 kV to 50 kV, IEC
61267 RQR-M
series
4.1 % 2 ~95% YesFree air
chamberLNE-LNHB
EUR-RAD-
LNE-
LNHB-
1082
Approved on
11 September
2013
NEUTRON MEASUREMENTS
Fluence rate
Neutron
sensitive
device
Irradiation with
calibrated neutron
sources
2.22E+02 2.22E+02 cm-2
s-1
Neutron
spectrum [at
1 m from the
source]
bare Cf-252 ISO
8529-15.6 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3001
Approved on
09 May 2005
Fluence rate
Neutron
sensitive
device
Irradiation with
calibrated neutron
sources
1.93E+02 1.93E+02 cm-2
s-1
Neutron
spectrum [at
1 m from the
source]
D2O-mod. Cf-252
ISO 8529-15.5 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3002
Approved on
09 May 2005
The BIPM key comparison database, September 2016 39/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Fluence rate
Neutron
sensitive
device
Irradiation with
calibrated neutron
sources
2.86E+02 2.86E+02 cm-2
s-1
Neutron
spectrum [at
1 m from the
source]
Am-241/Be-9 ISO
8529-15.3 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3003
Approved on
09 May 2005
Ambient
dose
equivalent
rate
Neutron
dosemeter
Irradiation with
calibrated neutron
sources
3.08E-04 3.08E-04 Sv h-1
Neutron
spectrum [at
1 m from the
source]
bare Cf-252 ISO
8529-36 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3004
Approved on
09 May 2005
Ambient
dose
equivalent
rate
Neutron
dosemeter
Irradiation with
calibrated neutron
sources
7.29E-05 7.29E-05 Sv h-1
Neutron
spectrum [at
1 m from the
source]
D2O-mod. Cf-252
ISO 8529-39.7 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3005
Approved on
09 May 2005
Ambient
dose
equivalent
rate
Neutron
dosemeter
Irradiation with
calibrated neutron
sources
4.02E-04 4.02E-04 Sv h-1
Neutron
spectrum [at
1 m from the
source]
Am-241/Be-9 ISO
8529-39.6 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3006
Approved on
09 May 2005
Personal
dose
equivalent
rate
Neutron
personal
dosimeter
Irradiation with
calibrated neutron
sources
3.20E-04 3.20E-04 Sv h-1
Neutron
spectrum [at
1 m from the
source and
for an angle
of incidence
of 0 deg]
bare Cf-252 ISO
8529-36 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3007
Approved on
09 May 2005
Personal
dose
equivalent
rate
Neutron
personal
dosimeter
Irradiation with
calibrated neutron
sources
7.60E-05 7.60E-05 Sv h-1
Neutron
spectrum [at
1 m from the
source and
for an angle
of incidence
of 0 deg]
D2O-mod. Cf-252
ISO 8529-39.7 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3008
Approved on
09 May 2005
The BIPM key comparison database, September 2016 40/41
Calibration and Measurement Capabilities
Ionizing Radiation, France, LNE (Laboratoire national de métrologie et d'essais)
QuantityInstrument or
Artifact
Instrument Type
or Method
Minimum
value
Maximum
valueUnits Parameter Specifications Value Units
Coverage
factor
Level of
Confidence
Is the
expanded
uncertainty a
relative one?
Reference
standard
Source of
traceability
NMI
Internal
Service
Identifier
Comments
Note: All services are provided by the LNE-LNHB (Commissariat à l'énergie atomique/Laboratoire National Henri Becquerel), except Services EUR-RAD-LNE-3001 to 3009 (included) that are provided by the LNE-
IRSN (Institut de radioprotection et de sûreté nucléaire)
Reference Standard used in
calibrationCalibration or Measurement Service Measurand Level or Range
Measurement
Conditions/Independent
Variable
Expanded Uncertainty
Personal
dose
equivalent
rate
Neutron
personal
dosimeter
Irradiation with
calibrated neutron
sources
4.20E-04 4.20E-04 Sv h-1
Neutron
spectrum [at
1 m from the
source and
for an angle
of incidence
of 0 deg]
Am-241/Be-9 ISO
8529-39.6 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3009
Approved on
09 May 2005
Emission rateNeutron source
(sealed)
Calibration in a
manganese bath1.00E+05 2.00E+08 s
-1 Radionuclide
sourceAm-241/Be-9 3 % 2 ~95% Yes
Standardised 56
MnLNE
EUR-RAD-
LNE-3010
Approved on
09 May 2005
Emission rateNeutron source
(sealed)
Calibration in a
manganese bath1.00E+05 2.00E+07 s
-1 Radionuclide
sourceAm-241/B 3 % 2 ~95% Yes
Standardised 56
MnLNE
EUR-RAD-
LNE-3011
Approved on
09 May 2005
Emission rateNeutron source
(sealed)
Calibration in a
manganese bath1.00E+05 2.00E+08 s
-1 Radionuclide
sourcePu/Be-9 3 % 2 ~95% Yes
Standardised 56
MnLNE
EUR-RAD-
LNE-3012
Approved on
09 May 2005
Emission rateNeutron source
(sealed)
Calibration in a
manganese bath1.00E+05 2.00E+08 s
-1 Radionuclide
sourceCf-252 3 % 2 ~95% Yes
Standardised 56
MnLNE
EUR-RAD-
LNE-3013
Approved on
09 May 2005
Emission rateNeutron source
(sealed)
Calibration relative
to a primary
standard
instrument
1.00E+02 1.00E+05 s-1 Radionuclide
sourceCf-252 30 to 8 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3014
Approved on
09 May 2005
Emission rateNeutron source
(sealed)
Calibration relative
to a primary
standard
instrument
1.00E+02 1.00E+05 s-1 Radionuclide
sourceAm-241/Be-9 30 to 8 % 2 ~95% Yes
Manganese
sulphate bathLNE
EUR-RAD-
LNE-3015
Approved on
09 May 2005
The BIPM key comparison database, September 2016 41/41