Presentation about things learnt at vocational training at IOCL, Panipat; various pumps and valves being used in the refinery, safety and environment practices, etc.

TRANSCRIPT

VOCATIONAL TRAINING PRESENTATION

By: VISHAL SRIVASTAVAMechanical EngineeringVII SemesterSKIT, Jaipur

IOCL, PANIPAT

INDIAN OIL-ENERGY OF INDIAKey player in Indian Energy SectorPSU Maharatna, meeting 47% of national petroleum demandsCapacity: 65.7 MMTPA63% market share in Aviation FuelLeading Indian Corporate, ranked at 83rd position in latest Fortune ‘GLOBAL 500’ listing

.

OperationsRefining

Pipeline Transportation

Petroleum Products and Petro-chemicals

Exploration of Crude Oil and Gas

ATF

SULPHUR

INDANE Gas

Xtra Premium Petrol

Petrochemicals

HSD

LPGSERVO Lubricants

BITUMEN

HEAVY PETROLEUM

STOCK

Products from Refinery

Barauni

Haldia Mathura Digboi

Guwahati Gujarat

Panipat

PANIPAT REFINERY

7th refinery of Indian oil .

Largest integrated Refinery and Petrochemicals Hub in India and 3rd in South-East Asia

Present Capacity: 15 MMTPA

Designed for high sulphur crude

0 Discharge Refinery

BASIC PROCESS IN REFINERY

MECHANICAL DEPARTMENT

Maintenance Various Components used:i. Centrifugal Pumps (SPLIT-CASING TYPE)ii. Screw Pumpsiii. Valvesiv. CompressorsMechanical Control Unit (MCU)

REQUIREMENT OF PUMPS IN REFINERY

• For circulation of cooling water

• For pumping the fluid (crude oil,diesel etc.) in reactors, etc. with high pressure.

• In liquid storage tanks

SPLIT CASING PUMP

to pump clean water or low viscosity clean liquids at moderate heads

Less noise and vibration

risk of water hammer is lower

Unique design for high temperature application

SCREW PUMP(+VE DISPLACEMENT)

• Used for High Viscous fluid

• High efficient as the flow increases

• mostly used for pumping lube oil

CAVITATION (NPSHA<NPSHR)

Cavitation Effects:

grinding of “marbles” Loss of capacity Pitting Vibration and mechanical damage such

as bearing failure Erratic power consumption

FAILURE MODES IN PUMP

Shaft Suction Valve Casing Operation CouplingGaskets Control Valve

REQUIRMENT OF VALVES

• Its function can be stopping or starting the flow, controlling flow rate, diverting flow

• preventing back flow, controlling pressure, or relieving pressure.

• control of fluid flow or pressure is required

• Very important for safety

GATE VALVEGLOBE VALVE

Non Return Valves

SAFETY VALVES

PRESSURE SAFETY VALVE PRESSURE RELIEF VALVE

ROLE OF A MECHANICAL ENGINEER

• Mechanical Control Unit (MCU)

• Monitoring various parameters

• Communication with the control room staff

• Troubleshooting the problems

ENVIRONMENT CONSERVATION PRACTICES

• AIR POLLUTION

• WATER POLLUTION

• NOISE POLLUTION

• OHC

AIR POLLUTION CONTROL

5 Sulphur Recovery Units (99% recovery)

Tall stacks

Use of low S fuel oil, desulfurised fuel gas

Low Nox burners

WATER POLLUTION CONTROLZero Discharge RefineryEffluent Treatment PlantLarge ponds for aerobic storage of treated waterBenzene Vapour Recovery System at Naptha

NOISE POLLUTION CONTROL & OHC

EarplugsSilencers on

compressorsAcoustic equipmentsRegular monitoring of

work environment under OHC

Development of Green Corridor and Ecological Park

SAFETY PRACTICES

LEARNINGSPractical experience

Insight into the working of a PSUs

Useful Interactions with people

Environment and safety practices in a industry