The Rain Switch efficiently and seamlessly manages the use of rainwater around the home. It is installed between the rainwater tank, town water supply and the rain water outlets.
It automatically uses rainwater from the water tank as the primary source to supply selected outlets such as toilets and outside taps. When there is no tank water, the Rain Switch seamlessly switches to town water.
The Rain Switch display panel indicates the water source in use. With the Rain Switch display panel you will always know when unrestricted use of rainwater is available for gardening, hosing and car washing.
The robust and practically designed Rain Switch is built to last while intelligently maximising rainwater use around your home.
The Remarkable Rain Switch:
•Managesefficientwaterusearoundthehomewithoutyouliftingafinger
•Canbeusedwithanyrainwatertank
•WaterMarklicensed
•Factorypressuretestedandrequiresnositeassembly
•Suppliestownwaterduringpowerblackouts
Introduction
1 - 5 Anzac AvenueSmeaton Grange NSW 2567
is a division of BioSeptic Pty Ltd - ABN 95 056 461 226
Ph: 02 4629 6633Fax: 02 4629 6677
Email: sales@sydneywatertanks.com.auWeb: www.sydneywatertanks.com.au
1
The Rain Switch kit includes:
•RainSwitch-housedwithinawaterresistantpowdercoatedsteelcabinet •Powdercoatedsteelskirtfittedunderthecabinettoconcealthepipework •Displaypanel-indicateswatersourceinuse •Waterpump-canbesuppliedwithRainSwitchorbyinstaller •Activationfloatswitch
Kit
When there is water in the tank.
When there is no usable water in the tank.
The display panel indicates when rainwater from the water tank is available and when town water is being used so that any current water use restrictions can be observed. The display panel can be mounted at any convenient position around the house.
Operation
Rain Switch with above ground tank and submersible pump 32
Action Operation
Activationfloatintheupposition Powerissuppliedtothepumpcontroller
Tapopenortoiletflushed Tank water supplied When the pump operates the normally open solenoidclosestostoptheflowoftownwater
Tap closed Pumpstopsandthesolenoidopens
Action Operation
Floatinthedownposition No power supplied to the pump controllerSolenoid valve is open Alloutletsaresuppliedbytownwater.
Rain Switch with above ground tank and surface mounted pump Rain Switch with underground tank and submersible pump 54
Activation float switch
Theactivationfloatswitchfloatsupwardswhenthereiswaterinthetankandsuppliespowertothepumpcontroller. The switch’s contacts are closed in the up position.
Pump Controller – located inside the Rain Switch cabinet
How the components function
Features
•Thepumpcontrollerstartsandstopsthepump whenever a tap is opened or closed
•Itmaintainsthewaterfromthetankataconstant pressure
•Itstopsthepumpif there isnowater inthe system, thus protecting the pump from dry running and causing permanent damage to the pump
• A non return valve in the Presscontrolprevents water from the house flowingback to the tank
Indicator lights
PowerOn Green Illuminatedonlywhentankwaterisinuse.
Pumpon Yellow Illuminatedwhenthepumpisoperating
Pumpfailure Red Indicatesapumpfault
Solenoid valve
Thenormallyopensolenoidvalveisclosedonlywhenthepumpisoperating.Itstopstheflowoftownwater. It is open when the pump is not operating. In the event of a power or pump failure the solenoid valve is open and town water is supplied.
Backflow prevention
Water authorities apply hazard ratings to water tanks. See AS/NZS 3500 Section 4.3 for ratings.Mostwatertanksareratedaslowhazard.Checkwithyourplumberorthelocalwaterauthorityforitsrequirementsforthetypeoftankyouhaveinstalled.
ZoneProtectionisrequiredatthepointwheretherainwaterandtownwaterareconnectedtopreventanyrainwaterflowingintothemainswaterreticulationsystem.TheRainSwitchcontainsanintegraldualcheck valve for zone protection.
ThewaterauthoritymayrequireasecondbackflowpreventiondevicetobefittedafterthewatermeteratthesiteboundaryforContainmentProtection.
The Rain Switch is also available with an integral testable double check valve if the installation is deemed to have a medium hazard rating.
Display panel ThepanelhastwoLEDlightsthatindicatewhetherTownorTankwater is available.
The display panel can be mounted on the outside of the box or at a convenient position inside the house.
When tank water is not available town water will be supplied.
76
The Rain Switch can be mounted at any convenient location between the tank and the first rain water outlet. The Rain Switch is pressure tested during the assembly process and requiresnositeassembly.
It is suggested that the plumber mounts the cabinet to suit the pipe positions.
The pipe size and method of connecting the water supply between the tank and the Rain Switch should comply with AustralianStandardAS3500.1:2003PlumbingandDrainage,Part 1 Water Services. A properly licensed plumbingcontractor must undertake the work.
Note: if the tank is located down hill or a long way from the house the use of larger pipe sizes will reduce friction loss and reduce the power consumption of the pump.
It is not advisable to mount the Rain Switch on bedroom or sitting room walls if the building is of brick veneer or other light weight type of construction. In some instances there may be water noise from the pipes which can be unsettling atveryquiettimes.
The cabinet is weather proof. Measure the length of thepump and float cables and mount the Rain Switch at aposition within the reach of the cables. If this is not possible anelectricianwillneedtoextendthepumpandfloatcableor preferably fit a junction box at a suitable position.
Mounting the cabinet Donotuseexcessiveforcewhenconnectingpipestothecabinet.Eachinletandoutletisclearlylabelled.Connectionsareby¾”nipplesandunions.Adirtboxstrainerissuppliedthatmustbefittedtothepumpline.This strainer protects the Rain Switch from any debris that has settled in the pipes during the construction phase of a new house. If an inline filter is being fitted to the pump line the dirt box strainer may be omitted.
AllconnectionsaremadeatthebaseoftheRainSwitchcabinet.Allconnectionpointsareclearlymarkedinsideandunderthecabinet.Tomakeiteasiertopullthepumpandfloatswitchcablesintoposition,fitlargeboreconduitbetweentheRainSwitchcabinetandthetank.32mmor40mmconduitisrecommended.
connections
The following components are connected to the Rain Switch
Component Direction Connector size
Pumpoutletpipe FrompumptoRainSwitch 20mmbrassnipple
Townwater FromsupplytoRainSwitch 20mmbrassnipple
Outletstobesupplied FromRainSwitchtooutlet 20mmbrassnipple
240vacdedicatedcircuit FromsupplytoRainSwitch 25mmfemaleadaptor
Pumpcable FrompumptoRainSwitch 25mmfemaleadaptor
Floatswitchcable FromtanktoRainSwitch 25mmfemaleadaptor
Display FromRainSwitchtopanel 12mmcablegland
The Rain Switch cabinet will only operate in the vertical plane and must be mounted in the vertical position. It should be screwed to the wall by the four mountingpoints.Acoverorskirtisavailabletobebolted to the base of the cabinet to conceal the pipes and electrical conduits.
Supplying power to the cabinet
AwiringinformationsheetfortheelectricianislocatedininsidetheelectricaljunctionboxinsidetheRainSwitch.
PowerfromaseparatecircuitbreakershouldbesuppliedtothejunctionboxinsidetheRainSwitchcabinet.
Connecting the pump and activation float cables Theelectricianshouldconnectthepumpandfloatcablesfromthetanktothejunctionbox.
Connectonlythebrownandblackwirestothefloatswitchinput.
98
Turning on the power for the first time
rainwatertapsorflushthetoilets,thismayhavetoberepeatedafewtimestocompletelypurgealloftheairfrom the plumbing system. When the taps are closed and the system is at the correct pressure the yellow light will be off.
If the correct pressure is not achieved the redFailurelightwillbeilluminated.Inthissituationopenanoutletsuch as the garden tap and press the red restart button until pressure builds up and the red Failurelightisoff.
Aftertheinitialstartupandifthereiswaterinthetank,theyellowPumponlightwillbeilluminatedwheneverthepumpisoperating.TheYellowpumplightwillbeoffwhenthepumpisnotoperating.
If there is usable water in the tank, the pump will automatically supply water to the outlets when there is power to the Rain Switch. If there is insufficient water in the tank, the outlets will be supplied by town water.
The green Power on light is permanentlyilluminated only when there is usable water in the tank.
To purge air from a new system open all of the
Troubleshooting the 1. Neither of the lights on the display panel are illuminated. Probablecause-thereisnopowertothesystem.CheckthepowertotheRainSwitchcabinettoconfirmthatthepowersupplyison.Theelectricaljunctionboxcontains240voltsandmustonlybeopenedbyalicensed electrical contractor. In this situation water will be supplied from the town supply.
2. Pump will not turn off when all outlets are closed. Cause-debrishasenteredtheRainSwitchandisstoppingthepumpcontrollerfromturningoffthepump.This should not occur if the dirt box strainer was fitted to the pump inlet before the pump was connected. To removethedebrisrequiresthepumpcontrollertobedismantled.Anelectricianmustdisconnectthepowerbefore the pump controller is dismantled and cleaned.
3. There is a ten second delay in the water supply to the selected outlets.Cause-thereisnowatersupplyfromtherainwatertank.CheckthepumpcontrollerinsidetheRainSwitchcabinet.Ifthefailurelightisilluminatedthepumphasmostlikelyfailed.CallRainSwitchon0246296633forassistanceorhavethepumpcheckedbyapumptechnician.
4. Tank light is illuminated on the display panel and the red pump failure light is also illuminated. Cause–thepumphasfailed.Haveanelectriciancheckthepowertothepumpfromtheelectricaljunctionbox in the cabinet. Repair or replace as necessary.
5. Wet spots around the tankCause–leakinpipeworkcausingthepumpnottoturnoff.Findandrepairleak.
6. Rain Switch constantly turning on and offCause-Dropinpressureinplumbingservice.Findandrepairdrippingtapsorleakingcisterns.Educateusers to turn off taps after use.
02 4629 6633
Connecting the Display PanelThe display panel is low voltage.
ConnecttheAandBterminalsinthejunctionboxtotheAandBterminalsonthedisplaypanel-donot reverse.
Mounting the Display PanelThere are two options for mounting the panel
On the Rain Switch cabinetThepanelcanbemountedoneithertheleftorrightoutsidefaceoftheRainSwitchcabinet.Choosethesidethatismostvisible.Drillasmallhole(3-5mm)throughwhichtopassthewireandusetwoselftappingscrews to mount the panel.
Inside the houseMountthepanelinasuitablepositionorinthehouseholder’spreferredposition.Eitherspeakerwireor1mmcable may be used to connect the display panel.
Electrical Junction Box
1110
RAIN SWITCH OPERATING DATA & COMPONENT SPECIFICATIONS
WaterMark approval number WMKA 21237
Quality Assurance auditor SAI GLOBAL
Designed to comply with ATS 5200.477
Maximum pressure of unit 10 bar (1 mpa)
Maximum liquid operating temperature 50oC
Minimum flow 5 litres/minute
Pump pressure >3 bar <10 bar
Recommended pump flow rate 40 litres/minute
Recommended main water supply pressure >2 bar <5 bar
STEEL CABINET
Material 1.5mm cold rolled steel – stove enamel finish
Protection rating IP 66
Security Two key locks Left opening
PUMP CONTROLLER
Type Electronic presscontrol
Required power supply 230 volts +/- 10%
Maximum current 16 (8) amperes
Maximum power of pump 1.5kW (2HP)
Protection rating IP 65
Maximum working pressure 10 bar (1 mpa)
Maximum working temperature 65oC
ACTIVATION FLOAT SWITCH IN TANK
Function Provides power to the pump controller
Operating power 12 volts
Cable PVC 2 x 1 20m cable
Protection rating IP 68
BACKFLOW PREVENTION TO TANK Non return valve in pump controller
PIPE WORK & FITTINGS
Brass fittings AS3688 - 1994 1” & ¾”
Copper pipe AS1432 ¾”
Connection points ¾” male
BACKFLOW PREVENTION TO RETICULATED WATER SUPPLY - low hazard rating - standard
Type Dual check valve
OPTIONAL - BACKFLOW PREVENTION TO RETICULATED WATER SUPPLY - medium hazard rating
Type Testable double check valve
Manufacturer Conbraco Model No 40104A1l
Hazard rating Medium
Device is Product Certified to AS2845.1
ELECTRICAL JUNCTION BOX
Power supply 240 volts
Control circuit 12 volts
DISPLAY PANEL
Power rating 12 volts
Indicator lights Town/tank supply LED x 2
1 - 5 Anzac AvenueSmeaton Grange NSW 2567
is a division of BioSeptic Pty Ltd - ABN 95 056 461 226
Ph: 02 4629 6633Fax: 02 4629 6677
Email: sales@sydneywatertanks.com.auWeb: www.sydneywatertanks.com.au
tap sign
Two rainwater signs are supplied with each Rain Switch to be fixed to the rainwater outlets.
1312