iconic wall collection - techo-bloc
Post on 07-Feb-2022
2 Views
Preview:
TRANSCRIPT
175
tech
o-bl
oc.c
om
WALLS &
PILARS
PALLET OVERVIEW - PANELS
www.techo-bloc.com
September, 2019
TS-PAL-ICONIC-1
ICONICStandard
PALLET OVERVIEW
PALLET OVERVIEW - CORNERS
www.techo-bloc.com
September, 2019
TS-PAL-ICONIC-1
ICONICCorner
PALLET OVERVIEW
COMPATIBLE CAPSSee page 141 for product compatibility.
Klean-Bloc technology will be available Spring 2021. See page 22.
Product is available in Natural Stone while quantities last.
NOTESSee page 136 to 157 for more technical information.
ICONIC FASCIA WALL COLLECTION
Iconic Fascia Wall collection
Specifications per pallet Imperial Metric
FASC
IA
Cubing
45 units 45 units
47.95 ft2 4.46 m2
97.44 lin. ft 29.70 lin. m
Approx. Weight 1 390 lbs 630 kg
Number of rows 3
Coverage per row 15.98 ft2 1.49 m2
Linear coverage per row 32.48 lin. ft 9.90 lin. m
L2
HDL1
Unit dimensions in mm Units /palletA Height 5 7/8 150 45 units
Depth 2 3/4 70Length 26 660
Specifications per pallet Imperial Metric
CORN
ER Cubing 24 units 24 units
Approx. Weight 700 lbs 318 kg
Number of rows 1
Pillar height 35 7/16 in 900 mm
L2
HDL1
Unit dimensions in mm Units /palletA Height 5 7/8 150 12 units
Depth 2 3/4 70Length 23 1/4 590
L2
HDL1
Unit dimensions in mm Units /palletB Height 5 7/8 150 12 units
Depth 2 3/4 70Length 23 1/4 590
LEFT UNIT
RIGHT UNIT
Rock Garden Brown Victoria Riviera Onyx Black
DESCRIPTION : Fascia Panel & Corner TEXTURE : Klean-Bloc Natural Stone (available Spring 2021) Natural Stone (while quantities last)
INSTALLATION GUIDE
177
tech
o-bl
oc.c
om
WALLS &
PILARS
Installation guides
FREESTANDING WALL
FREESTANDING WALL - 90° CORNER
GRAVITY RETAINING WALL
FASCIAFREESTANDING WALL
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-1
A
B
F
G
D
E
C
NOTE : THE PATTERNS ON THE PANELS ARE VARIABLE.
TEXTURED PANELWITH SIMULATEDJOINTS
H
I
A. TECHO-BLOC CAP UNIT SECURED TO CORE AND PANEL BELOW WITHCONCRETE ADHESIVE
B. STRUCTURAL BLOCK DOUBLE-SIDED UNITC. PANEL UNITD. 29 1/2'' (750 mm) MAX.E. EMBEDMENT DEPTH 6" (150 mm) MIN.F. GEOTEXTILEG. COMPACTED GRANULAR BASE 6" (150 mm) MIN. THICKNESS
ACCORDING TO PROJECT SPECIFICATIONSH. CONCRETE ADHESIVEI. HDPE HORIZONTAL KEYJ. BASE UNIT
J
FASCIAGRAVITY RETAINING WALL
D
H
I
K
L
M
J
N
GRAVITY WALL DETAIL
A. TECHO-BLOC CAP UNIT SECURED TO UNIT BELOW WITH CONCRETE ADHESIVE
B. STRUCTURAL BLOCK SINGLE SIDED UNIT
C. PANEL UNIT
D. WALL INCLINATION (5.3°)
E. HDPE HORIZONTAL KEY
F. EXPOSED HEIGHT
G. EMBEDMENT DEPTH
H. TOP SOIL
I. LOW PERMEABILITY SOIL
J. 3/4” (20 mm) CLEAN STONE
14" (350mm) THICK MIN.K. RETAINED SOIL
L. GEOTEXTILE
M. PERFORATED DRAIN
N. LEVELING PAD
O. FOUNDATION SOIL
P. CONCRETE ADHESIVE
Q. BASE UNIT
B
E
A
F
G
C
O
P
www.techo-bloc.com TS-SP-FASCIA-WR-EN-4
Q
FASCIAFREESTANDING WALL 90° CORNER
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-2
ODD ROW
EVEN ROW
STRUCTURALBLOCK DOUBLESIDED UNIT
LEFT PANEL
RIGHT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANELWITH SIMULATEDJOINTS
TEXTURED PANEL WITHSIMULATED JOINTS
STRUCTURALBLOCK DOUBLESIDED UNIT CUT /SPLITTED IN HALF
STRUCTURALBLOCK DOUBLESIDED UNITSTRUCTURAL
BLOCK DOUBLESIDED UNIT CUT/SPLITTED IN HALF
1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH ROW WITH CONCRETE ADHESIVE.4. APPLY ADHESIVE ON TOP OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.5. STRUCTURAL BLOCK DOUBLE SIDED UNIT CUT / SPLITTED IN HALF MUST ALWAYS BE PRESENT
AT THE CORNER OF THE WALL.
STRUCTURAL BLOCKDOUBLE SIDED UNIT CUT
CUT LINE
A. TECHO-BLOC CAP UNIT SECURED TO CORE AND PANEL BELOW WITH FLEXLOCK ADHESIVE
B. STRUCTURAL BLOCK DOUBLE-SIDED UNIT
C. PANEL UNIT
D. 29 1/2'' (750 mm) MAX.
E. EMBEDMENT DEPTH 6" (150 mm) MIN.
F. GEOTEXTILE
G. COMPACTED GRANULAR BASE 6" (150 mm) MIN. THICKNESS ACCORDING TO PROJECT SPECIFICATIONS
H. FLEXLOCK ADHESIVE
I. HDPE HORIZONTAL KEY
J. BASE UNIT
A. TECHO-BLOC CAP UNIT SECURED TO UNIT BELOW WITH FLEXLOCK ADHESIVE
B. STRUCTURAL BLOCK SINGLE SIDED UNITC. PANEL UNITD. WALL INCLINATION (5.3°)E. HDPE HORIZONTAL KEYF. EXPOSED HEIGHTG. EMBEDMENT DEPTHH. TOP SOILI. LOW PERMEABILITY SOILJ. 3/4” (20 mm) CLEAN STONE
14" (350mm) THICK MIN.K. RETAINED SOILL. GEOTEXTILEM. PERFORATED DRAINN. LEVELING PADO. FOUNDATION SOILP. FLEXLOCK ADHESIVEQ. BASE UNIT
1. ALTERNATE ODD AND EVEN ROWS.
2. STAGGER STRUCTURAL BLOCKS JOINTS FROM ONE ROW TO THE NEXT.
3. GLUE ALL STRUCTURAL BLOCKS AT EACH ROW WITH FLEXLOCK ADHESIVE.
4. APPLY FLEXLOCK ADHESIVE ON TOP OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
5. STRUCTURAL BLOCK DOUBLE SIDED UNIT CUT / SPLITTED IN HALF MUST ALWAYS BE PRESENT AT THE CORNER OF THE WALL.
PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.
INSTALLATION GUIDE
178
tech
o-bl
oc.c
omW
ALLS
& P
ILAR
S
FREESTANDING END OF A STRAIGHT WALL (OPTION 1)
FREESTANDING END OF A STRAIGHT WALL (OPTION 2)
FASCIAFREESTANDING END OF A STRAIGHT WALL
(OPTION 1)
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-3.1
ODD ROW
EVEN ROW
LEFT PANEL
RIGHT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
RIGHT PANELCUT
LEFT PANELCUT
FLEXLOCKADHESIVE
FLEXLOCKADHESIVE
STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)
STRUCTURALBLOCK DOUBLESIDED UNIT
STRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF
STRUCTURALBLOCK DOUBLESIDED UNIT
NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS
FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH
ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP
OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
FASCIAFREESTANDING END OF A STRAIGHT WALL
(OPTION 2)
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-3.2
ODD ROW
EVEN ROW
LEFT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
STRUCTURALBLOCK DOUBLESIDED UNIT
STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)
REGULAR PANELCUT
REGULAR PANELCUT
LEFT PANEL
RIGHT PANEL
FLEXLOCKADHESIVE
FLEXLOCKADHESIVE
STRUCTURALBLOCK DOUBLESIDED UNIT
RIGHT PANELSTRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF
NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS
FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH
ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP
OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
FASCIAFREESTANDING END OF A STRAIGHT WALL
(OPTION 1)
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-3.1
ODD ROW
EVEN ROW
LEFT PANEL
RIGHT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
RIGHT PANELCUT
LEFT PANELCUT
FLEXLOCKADHESIVE
FLEXLOCKADHESIVE
STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)
STRUCTURALBLOCK DOUBLESIDED UNIT
STRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF
STRUCTURALBLOCK DOUBLESIDED UNIT
NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS
FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH
ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP
OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
FASCIAFREESTANDING END OF A STRAIGHT WALL
(OPTION 2)
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-3.2
ODD ROW
EVEN ROW
LEFT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
STRUCTURALBLOCK DOUBLESIDED UNIT
STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)
REGULAR PANELCUT
REGULAR PANELCUT
LEFT PANEL
RIGHT PANEL
FLEXLOCKADHESIVE
FLEXLOCKADHESIVE
STRUCTURALBLOCK DOUBLESIDED UNIT
RIGHT PANELSTRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF
NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS
FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH
ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP
OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
FASCIAFREESTANDING END OF A STRAIGHT WALL
(OPTION 1)
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-3.1
ODD ROW
EVEN ROW
LEFT PANEL
RIGHT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
RIGHT PANELCUT
LEFT PANELCUT
FLEXLOCKADHESIVE
FLEXLOCKADHESIVE
STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)
STRUCTURALBLOCK DOUBLESIDED UNIT
STRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF
STRUCTURALBLOCK DOUBLESIDED UNIT
NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS
FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH
ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP
OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
FASCIAFREESTANDING END OF A STRAIGHT WALL
(OPTION 2)
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-WF-EN-3.2
ODD ROW
EVEN ROW
LEFT PANEL
REGULAR PANEL
REGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
STRUCTURALBLOCK DOUBLESIDED UNIT
STRUCTURAL BLOCKDOUBLE SIDED UNIT(WITH ONE TAILPIECE CUT)
REGULAR PANELCUT
REGULAR PANELCUT
LEFT PANEL
RIGHT PANEL
FLEXLOCKADHESIVE
FLEXLOCKADHESIVE
STRUCTURALBLOCK DOUBLESIDED UNIT
RIGHT PANELSTRUCTURAL BLOCKDOUBLE SIDED UNITCUT/ SPLITTED IN HALF
NOTES:1. ALTERNATE ODD AND EVEN ROWS.2. STAGGER STRUCTURAL BLOCKS JOINTS
FROM ONE ROW TO THE NEXT.3. GLUE ALL STRUCTURAL BLOCKS AT EACH
ROW WITH FLEXLOCK ADHESIVE.4. APPLY FLEXLOCK ADHESIVE ON TOP
OF UPPERMOST PANEL UNITS TO FIX CAP UNITS.
PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.
INSTALLATION GUIDE
179
tech
o-bl
oc.c
om
WALLS &
PILARS
FASCIA PILLAR
www.techo-bloc.com
Sep / 2019
TS-SP-FASCIA-PL-EN-1
ODD ROW
EVEN ROW
STRUCTURAL BLOCKSINGLE SIDED UNIT
STRUCTURAL BLOCKSINGLE SIDED UNITCUT / SPLITTED INHALF
RIGHT PANEL
LEFT PANEL
A
B
FG
D
E
C
TEXTURED PANEL WITHSIMULATED JOINTS
STRUCTURAL BLOCKSINGLE SIDED UNIT
STRUCTURAL BLOCKSINGLE SIDED UNITCUT / SPLITTED INHALF
STRUCTURAL BLOCK SINGLE SIDED UNIT CUT / SPLITTED IN HALF
CUT LINE
NOTE: SECURE EACH ROW WITHFLEXLOCK ADHESIVE.
A. PILLAR CAP UNIT SECURED TO CORE AND PANEL BELOW WITH FLEXLOCK ADHESIVE
B. RIGHT PANELC. LEFT PANELD. 35 7/16'' (900 mm) MAX HEIGHTE. EMBEDMENT DEPTH 6" (150 mm) MIN.F. GEOTEXTILEG. COMPACTED GRANULAR BASE 6"
(150 mm) MIN.THICKNESS ACCORDING TO PROJECT SPECIFICATIONS.
26"(660 mm)
26"(660 mm)
A. PILLAR CAP UNIT SECURED TO CORE AND PANEL BELOW WITH FLEXLOCK ADHESIVE
B. RIGHT PANEL
C. LEFT PANEL
D. 35 7/16'' (900 mm) MAX HEIGHT
E. EMBEDMENT DEPTH 6" (150 mm) MIN.
F. GEOTEXTILE
G. COMPACTED GRANULAR BASE 6" (150 mm) MIN.THICKNESS ACCORDING TO PROJECT SPECIFICATIONS.
For all possible combinations of pillars and caps, please refer to the correspondence table on page 141
PILLARS - FASCIA WALL COLLECTION
PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.
INSTALLATION GUIDE
180
tech
o-bl
oc.c
omW
ALLS
& P
ILAR
S
STEPS - FASCIA WALL COLLECTION
www.techo-bloc.com
June 2020
TS-SP-FASCIA-WST-EN-1
1-877-832-4625www.techo-bloc.com
FASCIA RIGHTPANEL
FASCIA LEFTPANEL
FASCIAREGULAR PANEL
TEXTURED PANEL WITHSIMULATED JOINTS
FASCIA REGULARPANEL CUT
FASCIA STRUCTURALBLOCK SINGLE-SIDED
UNIT CUT
CAP UNIT
FASCIA STRUCTURALBLOCK SINGLE-SIDED UNIT
FLEXLOCKADHESIVE
CAP UNIT
VARIABLE
5 7/8"(150 mm)
FASCIA PANELUNIT
5 7/8"(150 mm)
FASCIA BASEUNIT
FASCIASTEPS
FASCIA STRUCTURALBLOCK SINGLE-SIDED UNIT
FLEXLOCKADHESIVE
PLEASE REFER TO P.4 FOR THE CORRECT USE AND LIMITATIONS OF PROVIDED TECHNICAL INFORMATION.