i i i i i i i i...fire alarm call point (bs 5839) 9 litre foam extinguisher 9 litre water...
Post on 28-Feb-2021
2 Views
Preview:
TRANSCRIPT
South Lakeland District Council
Application to vary a premises licence under the Licensing Act 2003
PLEASE READ THE FOLLOWING INSTRUCTIONS FIRST
Before completing this form please read the guidance ·notes at the end of the form. If you are completing this form by hand please write legibly in block capitals. In all cases ensure that your answers are inside the boxes and written in black ink. Use additional sheets if necessary. You may wish to keep a copy of the completed form for your records.
We Lake District Leisure Pursuits Limited ---------------------------------------------------------------------------------------------------------------
being the premises licence holder, apply to vary a premises licence under section 34 of the Licensing Act 2003 for the premises described in Part 1 below
IPremises licence number
PL(A)0795
Part 1 - Premises Details
Postal address of premises or, if none, ordnance survey map reference or description Fallbarrow Holiday Park Rayrigq Road
Post town I Windermere I Post code I LA23 3DL
Telephone number at premises (if any)
Non-domestic rateable value of premises
Part 2 - A licant details
Daytime contact telephone number
E-mail address (optional)
Current residential address if different from premises address
Post Town
Part 3 - Variation
£323,000.00
Postcode
Please tick yes
Do you want the proposed variation to have effect as soon as possible? □
If not, from what date do you want the variation to take effect? Day Month Year
I I I I I I I I
Do you want the proposed variation to have effect in relation to the introduction of the late night levy? (Please see guidance note 1) □Yes IZ!No
TO TAKE EFFECT UPON THE COMPLETION OF WORKS AS NOTIFIED TO THE LICENSING AUTHORITY IN WRITING.
1
35
24
29
39
41
23
CW
16
18
15
20
15.1
HC
WC
20.1
GREY
5
W
Walk in Freezer
Internal Area - 3.0
14
W
Walk in Chiller
Internal Area - 3.2
14.1
10
HW
C
12
8
HCW
11
7
9
GREY
5
HW
C
21
1
2
3
19
4
37
17
36
40
27.1
38
22.2
22.1
CW
22
A
C
B
E
C
D
C
25
30
34
42
44
6 11.1
44
27.2
25.1
27
28
30.1
HCW
32
6
45
44
44
HW
C
12
31
37.1
46
43
45
33
33
33
GREY
5
45.1
44
47
[WS
]
[WS
]
MAIN KITCHEN
POOLOWNERS LOUNGE
PRIVATESALES
MAINOFFICE
CARAVANSALES
RECEPTION
DELI
SHOP
GENTS
LADIES
CELLARMAINTENANCESTORE
MAINTENANCEOFFICE
STORE
ACC.W.C. STORE
BOILERROOM
IC
Sign
IC
rampup
up
up
up
Storage for BBQ
CARAVANSALES
Store
Bar
Takeaway Existing
steps
Settle
Line of existing balustrade
Existingwoodburner
Chef'sTable
Chef'sTable
Line of existing balustrade
Existing games room
Office
4.4m2
High
chair
M&G
[WS]
[DISPLAY]
Menu
Existinghanging chair
A board
[4]
[4]
Ø1100
Existing balustrade
[ATM]
Stabledoor
Soft Play
VP
VP
K /BSB
K /BSB
K /BSB
SD/BSB
S17
S17
S17
S17
S17
S17
FireSuppression
tocookline byspecialist
S17
S13
S22
S22
S22
S22
S22
Fire Safety Requirements.
1. Doors & partitions required to be fire resisting are to be in accordancewith British Standard B.S. 476.
2. Fire resisting doors required to resist the passage of smoke atambient temperature conditions should, unless tested in accordancewith B.S. 476 section 311, to be fitted with a smoke seal.
3. The fire alarm system is to comply with British Standard B.S.5839;1:2013. Detection system to be linked into Landlord system toLandlord approved details.
4. The emergency lighting installation is to comply to British Standard5266:1:2016
5. Illuminated 'EXIT' signs are to conform to British Standard B.S. 2560.
6. Fire fighting equipment to conform to British Standard B.S. 5423.
7. Fire safety related signs & notices are to conform with BritishStandard B.S. 5449:1:2002.
8. Wall & ceiling linings are to be class 1 surface spread of flame (asdefined in British Standard B.S. 476 Pt. 7) in non-public areas & class0 (as defined in the Building Regulations) in routes of escape. (Toinclude fixed furniture)
9. Upholstered seating furniture should satisfy, as a minimum standard,(ignition source), (cigarette test) specified in British Standard B.S. 5852Pt.1 'Fire tests for furniture - Methods of test for ignitability by smokersmaterials of upholstered composites for seating' & British StandardB.S. 5852 Pt.2 'Fire tests for furniture - Methods of tests for ignitabilityof upholstered composites for testing by flaming source'. For whichlatter standard crib ignition source 5 is the minimum requirement.
10. Any fabrics which have received a flame retardant treatment shouldbe subjected to the water soak test detailed in British Standard B.S.5651 independant certification to the above standards should beprovided from an accredited test organisation.
11. Curtains & drapes are to satisfy type B, performance requirements ofBritish Standard B.S. 5867 Pt.2.
12. Artificial foliage & other decorative effects are to be fire retardant tothe satisfaction of the Fire Authority.
13. Textile floor coverings should be tested to British Standard B.S. 4790(Effects of small ignition source hot metal nut method).
14. Vertically hung textiles should conform to British Standard B.S. 5438.
A copy of the laboratory test report form an accredited testing laboratoryidentifying compliance of the furnishing composite with the abovementioned British Standards must be forwarded to this Authority beforeinstallation & confirmation that the furnishings specified in this certificatehave been installed in the premises.
NOTE: FIRE SEPARATION SUBJECT TO EXISTING FIRE STRATEGY -ALL DETAILS TO BE CONFIRMED BY SPECIALIST CONSULTANT
Sign - 'FIRE EXIT KEEP CLEAR' - 75mm letters
Strobe unit. Area covered visual alarm
Sign - internally illuminated 'FIRE EXIT' orgraphic equivalent
Area covered by Strobe / visual alarm(to be agreed on site)
Area covered by emergency luminaire.Certificates of compliance to B.S. 5839 (FireAlarms) and/ or B.S. 5266 (EmergencyLighting) to be provided to the fire Authority.
Vision panel
Fire alarm panel location TBC
FD30S ( fitted with automatic closer)
FD60S (fitted with automatic closers)
Fire blanket
Sign - 'FIRE DOOR KEEP SHUT' - 75mmletters
Sign - 'FIRE DOOR KEEP LOCKED' - 75mmletters
Fry fighter
Fire alarm call point (BS 5839)
9 litre foam extinguisher
9 litre water extinguisher
FIRE SAFETY INSTALLATION LEGEND
2kg carbon dioxide extinguisher
S13
S14
Fire alarm heat detector C/W strobe and electronicsounder base - addressable (BS 5839)
Fire alarm smoke detector - addressable (BS 5839)
Area covered by void smoke detection system(BS 5839)
Fire alarm smoke detector C/W strobe andelectronic sounder base - addressable (BS 5839)SD/BSB
Indicator for void detector
Push bar to open door mechanism
Door release linked to Fire Alarm, to BS EN 54-11:2001
ITEM TBC BY FIREALARM SPECIALIST
ITEM TBC BY FIREELECTRICALCONTRACTOR
Fire alarm repeater panel location TBC
Fire rated door grilles to match performance ofthe door
S
V
I
S17
S22
Z
P.B.
D.R.
F.A.P.
VP
Licensed AreaAll Licensable activities.
K /BSB
Fire alarm interface
DRAWING TO BE READ IN COLOURIN CONJUNCTION WITH BUILDERSWORKS PLANS
All existing fire doors to have intumescent fire strips andsmoke seals checked. If damaged allow for repair
NOTES
1. FIRE ALARM INSTALLATION TO BE L1 SYSTEM
2. FIRE SUPPRESSION TO BE INSTALLED OVER THECOOKING APPLIANCES WITHIN THE COOKLINE AREA
Existing areas covered by existing fire safety installations.specialist contractors to allow for upgrading and alterations to
suit proposed works where required
©This drawing is the property of Harrison Company Limited. Copyright is reservedby them and the drawing issued on condition that it is not copied either wholly orpart without the consent in writing of Harrison Company Limited. Figureddimensions to take preference over those scaled. All dimensions to be checked onsite before commencement of any work or shop drawings. This drawing is to beread in conjunction with the specification when existing.
REVISIONS
Rev By Date Comment
DRAWING NO.
DATE
PROJECT
CLIENT
SCALE @ A1
TITLE
DRAWN CHECKED
LONDON
DALLASBIRMINGHAM
+44 (0) 20 7046 6556+44 (0) 121 321 3030+1972 807 9257
Parkdean Resorts
Fallbarrow Holiday ParkCumbriaLA23 3DL
Licensing Layout
SeB KG
1:100 December 2020
4757/22/A
A CS 26.01.21 Wash up area amended
Area to be used for the sale of alcohol and regulated entertainment
top related