hiq solar truestring inverters a natural fit for rapid...

Post on 16-Sep-2020

3 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

HiQ Solar TrueString Inverters A Natural Fit for Rapid Shutdown

690.12 Rapid Shutdown Evolution*

No Requirement <30V Beyond 10ft of the Array Boundary Within 10s#

<30V Beyond 1ft of the Array Boundary Within 30s

<80V Within the Array Boundary

NEC 2011 and prior ✔

NEC 2014 ✔

NEC 2017 ✔

NEC 2017 after 1st Jan, 2019

NEC Compliant• Satisfies NEC 2014 Rapid Shutdown ‘10 foot rule’

requirements, within 10 seconds• Satisfies NEC 2017 Rapid Shutdown ‘1 foot rule’

requirements• Install under the array, throw the switch and the array

is isolated as per code requirements

Easy Design• Zero footprint within mandated walkways• Does not require cumbersome additional cradles to comply• Each string can be a different length

Easy Installation• AC and DC connectors are the certified means of disconnect,

saving cost• No special mounting, cradles, shade structures or

fireproofing required• Easy on, easy off, without hoists

Easy Maintenance• None required• Easy one-person replacement:

• 24 lb. is easy to carry onto and off the most demanding rooftop

• Connectors make install and replacement fast and simple• No fans, filters or airflow requirements

* Abbreviated requirements. Refer to respective NFPA 70® National Electrical Code® editions for more details. www.nfpa.org# As published, extended to 30s through TIA 14-10, effective date August 24th, 2016

© HiQ Solar Inc. 7th-Feb-2017, RPS-01-USData subject to change without notice

2030 Duane Avenue, Santa Clara, CA 95054info@hiqsolar.com, www.hiqsolar.com

Examples 2014 & 2017 Compliant TrueString Installs

top related